United States of America Department of Homeland Security United States Coast Guard Certificate of Inspection Certification Date: 28 Apr 2016 Expiration Date: 28 Apr 2021 For ships on international voyages this certificate fulfills the requirements of SOLAS 74 as amended, regulation V/14, for a SAFE MANNING DOCUMENT. Vessel Name Official Number IMO Number Call Sign Service POSEIDON 552864 Tank Barge Hailing Port HOUSTON, TX Hull Material Horsepower Propulsion Steel UNITED STATES Place Built GALVESTON, Texas UNITED STATES Delivery Date Keel Laid Date Gross Tons Net Tons 30Jun1973 R- R- I-6744 I-4388 DWT Length R-397.4 I-397.4 Owner MARTIN MARINE INC 925 North Rose City Drive Vidor, TX 77662 UNITED STATES Operator MARTIN MARINE INC 925 North Rose City Drive Vidor, TX 77662 UNITED STATES This vessel must be manned with the following licensed and unlicensed Personnel. Included in which there must be 0 Certified Lifeboatmen, 0 Certified Tankermen, 0 HSC Type Rating, and 0 GMDSS Operators. Masters Licensed Mates Chief Engineers Qualified Member Engineer Depts Chief Mates First Class Pilots First Assistant Engineers Oilers Second Mates Radio Officers Second Assistant Engineers Crew Members Third Mates Able Seamen Third Assistant Engineers Master First Class Pilots Ordinary Seamen Licensed Engineers Mate First Class Pilots Deckhands Non Licensed Engineer Depts In addition, this vessel may carry 0 Passengers, 0 Other Persons in crew, 0 Persons in addition to crew, and no Others. Total Persons allowed: 0 Route Permitted And Conditions Of Operation: ---Oceans--- Not on an International Voyage. ***SEE NEXT PAGE FOR ADDITIONAL CERTIFICATE INFORMATION*** With this Inspection for Certification having been completed at Port Arthur Texas UNITED STATES, the Officer in Charge, Marine Inspection, Marine Safety Unit Port Arthur certified the vessel, in all respects, is in conformity with the applicable vessel inspection laws and the rules and regulations prescribed thereunder. Annual/Periodic/Re-Inspection This Amended certificate issued by: Date Zone A/P/R Signature L. T. O'BRIEN, CDR, USCG, By direction Officer in Charge, Marine Inspection Inspection Zone Marine Safety Unit Port Arthur Dept. of Home Sec., USCG, CG-841 (Rev 4-2000)(v2) Page 1 of 4 OMB No. 2115-0517
United States of America Department of Homeland Security United States Coast Guard Certificate of Inspection Certification Date: 28 Apr 2016 Expiration Date: 28 Apr 2021 Vessel Name: POSEIDON ---Hull Exams--- Exam Type Next Exam Last Exam Prior Exam DryDock 06Feb2017 06Feb2012 01Mar2011 Internal Structure 06Feb2017 01May2014 06Feb2012 --- Liquid/Gas/Solid Cargo Authority/Conditions --- Authorization: FLAMMABLE/COMBUSTIBLE LIQUIDS AND SPECIFIED HAZARDOUS CARGOES Total Capacity Units Highest Grade Type Part151 Regulated Part153 Regulated Part154 Regulated 95316 Barrels A Yes Yes No *Hazardous Bulk Solids Authority* Not Authorized *Loading Constraints - Structural* Tank Location Description Maximum Load (short tons) Maximum Density (lbs/gal) 1 (P/S) 1597 13.20 2 (P/S) 3568 13.20 3 (P/S) 2542 13.20 4 (P/S) 3434 13.20 5 (P/S) 2131 13.20 *Conditions Of Carriage* Only those Category B, C, and D NLS cargoes named in the vessel s Cargo Authority Attachment (CAA), Serial #C1-1102433, dated August 3, 2011, may be carried. The specified hazardous cargoes may be carried only in the tanks indicated. The vessel does not comply with MARPOL Annex II and may only transport NLS cargoes regulated under Title 33 CFR or 46 CFR between U.S. ports via waters over which the U.S. has jurisdiction or on the high seas. This vessel is not equipped with an underwater discharge outlet meeting 46 CFR 153.470. The subject barge is prohibited from ballasting cargo tanks and shall not discharge residues of Noxious Liquid Substances (NLS) to sea; NLS residues must be discharged to a licensed facility. Per 46 CFR 150.130, the person in charge of the vessel is responsible for ensuring the compatibility requirements of 46 CFR 150 are met. Cargoes must be checked for compatibility using figures, tables, and appendices of 46 CFR 150 in conjunction with the reactive group number from the Compat Group No column is listed in the vessel s CAA. When the vessel is carrying cargoes containing 0.5% or greater benzene by volume, the person in charge is responsible for ensuring the provisions of 46 CFR Part 197, subpart C are applied. *Vapor Control Authorization* Per 46 CFR Part 39, excluding part 39.40, this vessel's vapor collection system (VCS) has been inspected to the plans approved by CG MSC letter serial # C2-0603406 dated 21NOV06, and has been found acceptable for the collection of those bulk liquid cargo vapors annotated with Yes in the VCS column of the vessel s CAA. The VCS system has been approved with a pressure side 1.5 psig P/V valve with Coast Guard Approval 162.017/144/4. The cargo tank top is suitable for a maximum allowable working pressure (MAWP) of 3 psi. *Stability and Trim* Dept. of Home Sec., USCG, CG-841 (Rev 4-2000)(v2) Page 2 of 4 OMB No. 2115-0517
United States of America Department of Homeland Security United States Coast Guard Certificate of Inspection Certification Date: 28 Apr 2016 Expiration Date: 28 Apr 2021 Vessel Name: POSEIDON Per 46 CFR 151.10(c)(2) the maximum tank weights listed above reflect uniform(within 5%) loading at the deepest draft allowed. When carrying subchapter "O" cargoes at shallower drafts, the barge should always be loaded uniformly. --- Inspection Status --- *Cargo Tanks* Internal Exam External Exam Tank Id Previous Last Next Previous Last Next 1 (P/S) 20Feb2002 06Feb2012 06Feb2022 - - - 2 (P/S) 20Feb2002 06Feb2012 06Feb2022 - - - 3 (P/S) 20Feb2002 06Feb2012 06Feb2022 - - - 4 (P/S) 20Feb2002 06Feb2012 06Feb2022 - - - 5 (P/S) 20Feb2002 06Feb2012 06Feb2022 - - - Hydro Test Tank Id Safety Valves Previous Last Next 1 (P/S) - - - - 2 (P/S) - - - - 3 (P/S) - - - - 4 (P/S) - - - - 5 (P/S) - - - - *Boilers/Steam Piping* Maximum Steam Pressure Allowed: 90 Hydro Inspection Mount Inspection Boiler/Piping ID Previous Last Next Previous Remove Open 45058712 - - - - - - Fireside Inspection Waterside Inspection Boiler/Piping ID Previous Last Next Previous Last Next 45058712 - - - - - - *Pressure Vessels* Type Location Previous Last Next Air Receiver - 06Feb2012 06Feb2017 ---Conditional Portable Fire Extinguisher Requirements--- Required Only During Transfer of Cargo or Operation of Barge Machinery --- Fire Fighting Equipment --- Number of Fireman Outfits - Number of Fire Pumps - 0 *Fire Extinguishers - Hand portable and semi-portable* Quantity 5 B-II Class Type Dept. of Home Sec., USCG, CG-841 (Rev 4-2000)(v2) Page 3 of 4 OMB No. 2115-0517
United States of America Department of Homeland Security United States Coast Guard Certificate of Inspection Certification Date: 28 Apr 2016 Expiration Date: 28 Apr 2021 Vessel Name: POSEIDON ---Certificate Amendments--- Unit Amending Amendment Date Amendment Remark Marine Safety Unit Port Arthur 17May2016 CORRECTED AIR RECEIVER NEXT INTERNAL INSPECTION DUE DATE ***END*** Dept. of Home Sec., USCG, CG-841 (Rev 4-2000)(v2) Page 4 of 4 OMB No. 2115-0517