Hard Water Softening by Chronoamperometry

Similar documents
Effect of temperature on the efficiency of inorganic phosphate used as antiscaling inhibitors

Use of Chemical Technical Rcp for the Inhibition of Scaling from Hard Water by a Green Inhibitor: Quercitine

FilterSorb SP3 Treatment Method: Part II

Process water quality factors

1. Scaling. H.O.: H-5/21, KRISHNA NAGAR, DELHI Tel.: , Fax:

Lecture 6: Softening

The Effect of an Additive on Morphology of Sodium Chloride Crystals in Seeded Batch Cooling Crystallization

Hybrid RO & Softening Birjand Water Treatment Plant

REMOVAL OF HARDNESS BY PRECIPITATION

BOILER FEED WATER AND ITS TREATMENTS

ANQUE High rate crystallisation processes: Application to softening and removal of scaling compounds for industrial wastewater re-use

Hard water. Hard and Soft Water. Hard water. Hard water 4/2/2012

Polymorph Screening Technology by Controlling Crystallization

The Effect of Calcium Nitrite on the Electrochemical Characterization of 3003 Aluminum Alloys in Sea Water. H.Mogawer and R.Brown

APPLICATION OF REVERSE OSMOSIS IN TREATMENT OF WATER USED IN INDUSTRIAL COOLING CIRCUITS

Using Hydrated Lime and Dolomite for Sulfur Dioxide Removal from Flue Gases

Study of the effect of deposit of allotropic forms of calcium carbonate and related carbon steel interface behavior

Thermal Desalination Process Based on Self-Heat Recuperation

Lecture 1: Introduction

Alkalinity: An Important Parameter in Assessing Water Chemistry

Lafayette College Department of Civil and Environmental Engineering

Revolution. NON-Chemical Treatment. Technology. for Scale Control. 500 different Applications NON TOXIC FOR POLLUTION PREVENTION AND GREEN TECHNOLOGY

Recirculating Hot Water Systems

A Cost Effective Technique for Chemical Wastes Reduction in Lime Water Softening Process

ABSTRACT: Clean sampling and analysis procedures were used to quantify more than 70 inorganic chemical constituents (including 36 priority

Steamate* technology. superior protection against condensate system corrosion. Water Technologies & Solutions technical bulletin

UNIT-I WATER TECHNOLOGY

EEC. Corrosion Study Unit PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Engineering and Technical Teaching Equipment

Influence Assessment of Operating Parameters in Synthesis of Zn-Ni Alloys for Process Electrodeposition

Modelling and Simulation of MSF Desalination Plant: The Effect of Venting System Design for Non-Condensable Gases

1. The equation that represents the equilibrium in a saturated solution of Fe 2 (SO 4 ) 3 is.. The precipitate which forms first is

SIGNIFICANCE OF HYDROGEN EVOLUTION IN CATHODIC PROTECTION OF STEEL IN SEAWATER

Removal of Phosphate from Aqueous Solution by Crystallization Using Coal Fly Ash

Influence of Electrochemical Water Treatment on Carbon Steel Corrosion

Sodium Peroxides (Na 2 O 2 ): Preparation: It is formed by heating the metal in excess of air or oxygen at 300, which is free from

New Approaches on Non Ferrous Metals Electrolysis

Lecture 18. Soil Acidity, Alkalinity, and Socidity

General Principles of Biomineralization

Optimal Production of Biohydrogen Gas via Microbial Electrolysis Cells (MEC) in a Controlled Batch Reactor System

Rusting is an example of corrosion, which is a spontaneous redox reaction of materials with substances in their environment.

Understanding Pretreatment. WesTech Engineering, Inc. Salt Lake City, Utah, USA

Phosphorus Removal and Recovery from High Phosphorus Wastewater by the HAP Crystallization Process

PAPER No.4 : Environmental Chemistry MODULE No.13 : Advanced Waste Water Treatment

Saving Energy and Water. Working with High Recovery Water Treatment Plants

Department of Civil Engineering, IIT Delhi (India) CVL722 (Sem1, ) (Dr. Arun Kumar;

DRINKING WATER - LAB EXPERIMENTS LAB EXPERIMENTS. Softening

Corrosion and Protection of Metal in the Seawater Desalination

Distribution Review. Corrosion Control. Corrosion Control Vocabulary. American Water College 1. Corrosion Control Training Objectives

Anti Scale Magnetic Method as a Prevention Method for Calcium Carbonate Scaling (DSL.3)

Preparation of needle-like aragonite particles from calcium nitrate solution

Brackish Ground Water Desalination: Challenges to Inland Desalination Technologies (It sure ain t seawater desalination)

Diagenesis, mineral replacement and porosity generation. Andrew Putnis & Christine V. Putnis

Total Dissolved Solids

Guideline for Prevention of Damage in Water Heating Installations

Control of the Physical and Technical Properties of Water in Technological Processes

Quantitive Chemistry Question paper

Duncan. UNIT 8 - Chemical Equations BALANCING EQUATIONS PRACTICE WORKSHEET 14.) C2H6 + O2 CO2 + H2O. 2.) Na + I2 NaI 3.) N2 + O2 N2O 4.

ALKALINITY ADDITION: THEORY AND BEST PRACTICE

Comparison of Sweepgas and Vacuum Membrane Distillation as In-Situ Separation of Ethanol from Aqueous Solutions

SRI RAMAKRISHNA INSTITUTE OF TECHNOLOGY COIMBATORE First Year BE/B.TECH ( ) Engineering Chemistry- I

Effect of soil compositions on the electrochemical corrosion behavior of carbon steel in simulated soil solution

Some Basic Concepts of Chemistry

MAVEA Professional. Basics on water

Corrosion of Electrical Submersible Pumps (ESP) In South Rumaila Oil Field

Respirometric BOD 5 determination of waste water polluted with organic or inorganic toxins or inhibitors. OxiTop pressure measuring heads

Chemical reactions and electrolysis

Ways towards an accelerated formation of protective layers on CuNi 90/10 in artificial seawater

OPTIDOSE 4210 Traceable Polymeric Acid Scale Inhibitor and Dispersant

The treatment for water destined for human consumption, maintenance-free

ACUMER 2200 High Performance Scale Inhibitor

Treatment Technologies

Extreme Recovery Membrane Process and Zero Liquid Discharge Low Temperature Crystallization for Treating Scaling Mine Waters

EVALUATING MITIGATION METHODS FOR CHLORIDE INDUCED CORROSION OF REINFORCED CONCRETE STRUCTURES

Avon Lake Corrosion Control Study and Orthophosphate Implementation. Andrew Skeriotis, Stantec Greg Yuronich, Avon Lake Regional Water

3. [7 points] How many significant figures should there be in the answer to the following problem?

Sensitivity Analysis for Optimisation of Brine Purification Process

Phosphate recovery from sewage sludge in combination with supercritical water oxidation

Silica Scaling in Water Treatment: Mechanism and Mitigation

Undesirable impurities in boilers. Maximum permissible Cycles of concentration (NC)

ppm Dissolved Oxygen Measurement

Chemical treatment of acid mine drainage. Anna Gulkova, Water and Environmental Engineering, Aalto University

Heat Integration Across Plants Considering Distance Factor

On-Site Sodium Hypochlorite Generation Equipment

Efficient Power Generation from Low Temperature Heat Source

2. WATER. Wet Processing I (Pretreatment)

METALS AND THEIR COMPOUNDS

Application of Slag Compound as a Curing Agent for Dealing With Salt Expansion in Coastal Saline Soil

Evaluation of Hemp (Cannabis Sativa L.) Quality Parameters for Building Material from Foam Gypsum Products

Operation manual. Kalkwasserreaktor

Reducing of a Scalling in a Cooling Tower by Areation Process

Nutrient Cycling in an Aquatic Ecosystem

Chapter 9 Systematic Equilibrium

We have softening plant for boiler so water treatment chemicals is not require. We used 90 % condensate water so no need of any chemicals treatment

EFFECT OF MAGNETIC TREATED IRRIGATION WATER ON SALT REMOVAL FROM A SANDY SOIL AND ON THE AVAILABILITY OF CERTAIN NUTRIENTS

Evaporative Condenser Passivation. Cameron Klein Strand Associates, Inc.

SOME CONSIDERATIONS WHEN APPLYING LIMESTONE/ROCK PHOSPHATE MATERIALS ON TO ACID PYRITIC SPOILS

DISSOLUTION OF ALUMINUM ELECTRODES IN CHLORIDE SOLUTIONS AT POLARIZATION BY THREE-PHASE CURRENT

Issues in Shrimp Pond Water and Sediment Quality Management

Table of Contents. Preface...

ENVIRONMENTAL ENGINEERING LECTURE 3: WATER TREATMENT MISS NOR AIDA YUSOFF

Transcription:

2347 A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 43, 2015 Chief Editors: Sauro Pierucci, Jiří J. Klemeš Copyright 2015, AIDIC Servizi S.r.l., ISBN 978-88-95608-34-1; ISSN 2283-9216 The Italian Association of Chemical Engineering Online at www.aidic.it/cet DOI: 10.3303/CET1543392 Hard Water Softening by Chronoamperometry Souheila. Ghizellaoui a, Samira. Ghizellaoui* b, a Ecole Nationale Supérieure de Biotechnologie, Ali Mendjli BP.E66 25100, Constantine, ALGERIE. b Départment of Chemical, University Constantine1, Route de Ain El Bey 25000 ALGERIA. gsamira@yahoo.com Water distributed from the Hamma resource is supersaturated on carbonate of calcium, a not very soluble salt and a major component of tartar. During their circulation in the network, these waters give rise to scaling phenomenon which involves a significant economic problem because of the low thermal conductivity of the solid layer which reduces the output of the exchangers of heat. Moreover, the increase of the thickness of tartar reduces the water flow and causes the seizing of the valves and taps. The maintenance of the furred installations or the replacement of the drains is very expensive. For this reason, several chemical and electrochemical processes were applied for the evaluation and the inhibition of the furring capacity of the earthy waters of Hamma which feed the town of Constantine with drinking water. Electrocrystallization was executed on a steel electrode to study germination and growth of the calcium carbonate crystals. The method of accelerated scaling was also considered in the presence of lime, sodium carbonate and soda. The results indicated that water of Hamma is furring. The use of the method of accelerated scaling and the follow-up of electrocrystallization gave satisfactory results. 1. Introduction In the grounds of calcareous nature, the subsoil waters of Hamma become charged in significant concentrations of hydrogenocarbonate of calcium. For a content of 60French degrees, water is known as very hard and must undergo a treatment of softening or decarbonation before use, because they deposit significant quantities of calcium carbonate during their circulation in the network of distribution. Several methods of the evaluation of the furring capacity of a water were carried out these last years (Boulahlib-Bendaoud et Ghizellaoui, 2015, Chaussemier et al., 2015, Ghizellaoui et al., 2004, Ghizellaoui et al., 2005, Ghizellaoui et al., 2007, Ghizellaoui et Euvrard, 2008, Semineras et Ghizellaoui, 2015). In this Study, first of all, the electrocrystallization was executed on a steel electrode to study germination and growth of the calcium carbonate crystals. Then another electrochemical process (accelerated scaling) in the presence of lime, sodium carbonate and soda was considered for the evaluation and the inhibition of the furring capacity of waters of Hamma.. 2. Material and methods 2.1 Characteristics of the water from Hamma The physicochemical results of the analysis of Hamma water are recapitulated in Table 1. Please cite this article as: Ghizellaoui S., Ghizellaoui S., 2015, Hard water softening by chronoamperometry, Chemical Engineering Transactions, 43, 2347-2352 DOI: 10.3303/CET1543392

2348 By considering these results, we see that water of Hamma has a significant relative content of organic matter (TOC: 3.84-7.5 mg/l). In addition, it is strongly mineral-bearing with a significant hardness (TH: 475-600 mg/l CaCO3). Therefore it is a primarily calcium bicarbonate (Ghizellaoui, 2008). Table 1. Hamma water analysis Temperature C 31-33 ph 6.95-7.94 EC ms/cm 0.9-1.30 TOC mg/l 3.84-7.50 CO2 mg/l 16.21-37.05 HCO3 - mg/l 320-432 Cl mg/l 128-150 SO4 2 - mg/l 120-212 PO4 3 - mg/l 0.006-0.020 NO3 - mg/l 3.90-7,00 NO2 - mg/l 0-0 NH4 + mg/l 0-0 Total hardness mg/l 475-600 CaCO3 Ca 2+ mg/l 124-131 Mg 2+ mg/l 30.48-43.20 Na + mg/l 84-115 K + mg/l 2.22-13 2.2 Tests of accelerated scaling This technique was developed by Lédion et al. 1985 (Fig. 1). Its principle consists in covering with CaCO3 a metal surface carried to a fixed negative potential of -1 V compared to an electrode of reference to calomel saturated with KCl. The application of this negative potential involves the reduction on the surface of metal primarily, of oxygen, according to the equation: O2 + 2 H2O + 4 e - 4 OH - In the vicinity of this electrode, the presence of the ions hydroxides involves an increase in the ph locally and the hydrogenocarbonate ions can be transformed into ions carbonates according the reaction: HCO3 - + OH - CO3 2- + H2O The increase in the content of CO3 2- then involves the precipitation of calcium carbonate on the surface of the electrode according to the reaction: Ca 2+ + CO3 2- CaCO3 (Solid) 2 1. Potensiostat-galvanostat 2. Voltmeter to control potential. 1 10 11 7 8 6 3 5 4 AGITATEUR 9 + - 3. Beaker of glass of 600 ml 4. Magnetic stirrer. 5. Bar magnet. 6. Electrode of reference to Calomel saturated with KCl. 7. Platinium Electrode. 8. Sample : pelletizes out of steel XC10 (diameter 11.3mm) drowned In an inert resin. 9. Plotting table. 10. Lid electrode holder Fig.1. utilisated Assembly

2349 3. Results 3.1. Qualitative results of electrocrytallization The first crystals obtained from the water of Hamma appear after 2 minutes of polarization. At the end of 60 minutes, there is growth of the latter without appearance of others. We observed a spontaneous nucleation followed by a crystals growth on all the surface of the electrode (Fig. 2). t=2min t=5min t=20min t=60min Fig.2. Germination and crystallization of water of Hamma 3.2. Curve of accelerated scaling for the water of Hamma The shape of the I=f(t) curve is given by (Fig. 3).The intensity decreases as the deposit covers metal surface gradually.the intersection of the tangent of inflection of the curve of accelerated scaling centered time corresponds to te (time of conventional scaling). It is the time which represents the total covering of the electrode with CaCO3. The water is more furring as the time of scaling is short. Therefore, we noticed that te for Hamma is of 3.7 minutes and its residual current is weak. What involves the formation of calcium carbonate a quite adherent precipitate. Fig.3. Curve of accelerated scaling for the water of Hamma. 3.3 Inhibition of scaling by sodium carbonate and lime 3.3.1 Use of the sodium carbonate Increasing concentrations of Na2CO3 were used (200-600 mg/l) at 30 C.The study of the curve with 400 mg/l of Na2CO3 revealed an increase in the time of scaling until 15.4 minutes and a weak residual current (Fig. 4). What corresponds to the formation of a quite adherent precipitate scaling. Beyond 400 mg/l there is total inhibition of scaling.

2350 Fig.4. Curve of accelerated scaling for the water of Hamma added with 400 mg/l of Na2CO3. 3.3.2 Use of lime The lime (100-500 mg/l) was added to the water of Hamma. The effect of lime is more significant than the addition of Na2CO3. For the same concentration (400 mg/l), the time of scaling increased until to reach 27 minutes and form of chronoamperometric curve is modified (Fig. 5). Fig.5. Curve of accelerated scaling for the water of Hamma added with 400 mg/l of lime. 3.3.3 Use of soda The tests of accelerated scaling carried out on the water of Hamma at 30 C for various soda concentrations (100-400 mg/l) showed that the time of scaling becomes significant as the soda concentration increases. The inhibiting effect marked is characterized by obtaining of a line for an addition of 400 mg/l of soda where the time of scaling is infinite (Fig. 6).

2351 Fig.6. Curve of accelerated scaling for the water of Hamma added with 400 mg/l of soda. 3.4 Evolution of the time of scaling and the residual current according to the addition of the lime, sodium carbonate and soda The study of the curves obtained, shows that the effect of the reagents (lime, sodium carbonate and soda) involves at the same time an increase in the time of scaling and an increase in the intensity of the residual current. These compounds which are adsorbed on the surface of the calcium carbonate particles which can be formed, may involve the precipitation of the calcium carbonate. It is noted that the time of scaling increases with the sodium carbonate concentration, lime and soda (Fig.7). One can consider, that starting from 500 mg/l of Na2CO3, 500 mg/l of Ca(OH)2 and 400 mg/l of NaOH, the time of scaling becomes practically infinite, the calcium carbonate stops to adhere to the electrode. Time of scaling (min) 70 60 50 40 30 20 Na2CO3 Ca(OH)2 NaOH 10 0 0 100 200 300 400 500 600 700 800 Concentration (mg/l) Fig.7. Evolution of the time of scaling according to the concentration The measurement of the residual current is carried according to the concentration of (lime, sodium carbonate and soda) (Fig. 8). This residual current measures the speed to which dissolved oxygen is reduced to the electrode covered with the calcium carbonate deposit. The increase of the compactness and adherence of the deposit reduces the oxygen diffusion through this insulating film. What thus will involve a reduction in the residual current.

2352 Residul current (ma) 3.8 3.3 2.8 2.3 1.8 1.3 0.8 0.3-0.2 Na2CO3 Ca(OH)2 NaOH 0 100 200 300 400 500 600 700 Concentration (mg/l) Fig.8. Evolution of the residual current according to the concentration 4. Conclusion To characterize water of Hamma which feed the town of Constantine with drinking water, the chemical analysis which presents hardness of 60 F reveals a furring character of the water. The compact and adherent deposits formed, crystallize in the form of calcite. The use of the electrocrystallization revealed also a spontaneous nucleation followed by a crystal growth. The tests of electrodeposition, carried out on furring water of Hamma, showed that CaCO3 overlaps steel at a very short time of scaling (te=3.7 minutes). However after treatment, this time becomes high (> 3.7 minutes).the role of the chemical treatments (lime, sodium carbonate and soda) is clearly highlighted and it is possible to determine the adequate concentration of these reagents to soften the water of Hamma. The residual current for the whole of the curves of electrodeposition is weak and thus involves the formation of compact and adherent layers of sediment. References Boulahlib-Bendaoud Y, Ghizellaoui S. 2015. Effect of temperature on the efficiency of inorganic phosphate used as antiscaling inhibitors. J. Mater. Environ. Sci. 6 (2): 307-314 Chaussemier M, Pourmohtasham E, Gelus D, Pécoul N, Perrot H, Lédion J, Cheap-Charpentier H, Horner O. 2015. State of art of natural inhibitors of calcium carbonate scaling. Desalination 356: 47-55. Ghizellaoui S, Ledion J, Ghizellaoui S, Chibani A. 2004. Etude de l inhibition du pouvoir entartrant des eaux du Hamma par précipitation contrôlée rapide et par un essai d entartrage accéléré, Desalination 166: 315-327. Ghizellaoui S, Chibani A, Ghizellaoui S. 2005. Use of nanofiltration for partial softening of very hard water, Desalination 179: 315-322. Ghizellaoui S, Euvrard M, Ledion J, Chibani A. 2007. Inhibition of scaling in the presence of copper and zinc by various chemical processes, Desalination 206: 185-197. Ghizellaoui S, Euvrard M. 2008. Assessing the effect of zinc on the crystallization of calcium carbonate, Desalination 220: 394-402. Ghizellaoui S. 2008. Evaluation and evolution of the quality of the water resources in the distribution network, Desalination 222: 502-512. Ledion J, Leroy P, Labbe J P. Juillet-Août 1985. Détermination du caractère incrustant d une eau par un essai d entartrage accéléré, TSM: 323-328. Semineras H, Ghizellaoui S. 2015. Use of chronoamperometry for the inhibition of scaling in hard waters. J. Mater. Environ. Sci. 6 (2): 377-382.