SEISMIC DESIGN REQUIREMENTS FOR REINFORCED CONCRETE BUILDINGS

Similar documents
EVOLUTION OF UBC AND IBC STATIC LATERAL FORCE PROCEDURE

Division IV EARTHQUAKE DESIGN

0306 SEISMIC LOADS GENERAL

See original reference (CODE) for full details

3.5 Tier 1 Analysis Overview Seismic Shear Forces

Engr. Thaung Htut Aung M. Eng. Asian Institute of Technology Deputy Project Director, AIT Consulting

STRUCTURAL DESIGN REQUIREMENTS (SEISMIC PROVISIONS) FOR EXISTING BUILDING CONVERTED TO JOINT LIVING AND WORK QUARTERS

> 0. 1 f, they are treated as beam-columns.

SEISMIC DESIGN OF STRUCTURE

IS 1893 and IS Codal Changes

Design Criteria For Reinforced Concrete Columns Under Seismic Loading

Special Reinforced Concrete Structural Walls

Special Civil Engineer Examination Seismic Principles Test Plan

CODE PROVISIONS RELATED TO SOILS AND FOUNDATIONS

Earthquake Resistant Design. Dr. S. K. PRASAD Professor of Civil Engineering S. J. College of Engineering, Mysore

Comparison of Azerbaijan and other seismic codes

3. Analysis Procedures

International Journal of Advance Engineering and Research Development REVISION OF IS: A REVIEW (PART 2)

INVESTIGATION ON NONLINEAR ANALYSIS OF EXISTING BUILDING AND INTRODUCING SEISMIC RETROFITTING OUTLINES WITH CASE STUDY

EARTHQUAKE HAZARD REDUCTION IN EXISTING CONCRETE BUILDINGS AND CONCRETE WITH MASONRY INFILL BUILDINGS

A Comparative Study on Seismic Analysis of Bangladesh National Building Code (BNBC) with Other Building Codes

Comparative Study of Irregular-shaped RC Building with Different Lateral Load Resisting Systems

CALTRANS SDC PROCEDURE

4.2 Tier 2 Analysis General Analysis Procedures for LSP & LDP

Seismic Detailing Provisions BNBC

Trends in the Seismic Design Provisions of U.S. Building Codes

Comparative Analysis of Moment Resisting Frames of Steel and Composite Materials

Question 8 of 55. y 24' 45 kips. 30 kips. 39 kips. 15 kips x 14' 26 kips 14' 13 kips 14' 20' Practice Exam II 77

Seismic Performance of Residential Buildings with Staggered Walls

Letter of Transmittal

sixteen seismic design Earthquake Design Earthquake Design Earthquake Design dynamic vs. static loading hazard types hazard types: ground shaking

Comparative Study on Dynamic Analysis of Irregular Building with Shear Walls

Reinforced Concrete Tilt-Up Wall Panel Analysis and Design (ACI 551)

ACI Code Revisions Impact on StructurePoint Software

A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures

STRUCTURAL APPLICATIONS OF A REINFORCED CONCRETE BEAM-COLUMN-SLAB CONNECTION MODEL FOR EARTHQUAKE LOADING

EARTHQUAKE DESIGN CONSIDERATIONS OF BUILDINGS. By Ir. Heng Tang Hai

The International Conference on Earthquake Engineering and Seismology. Naveed Anwar. ICEES April 2011 NUST, Islamabad Pakistan

EVALUATION OF NONLINEAR STATIC PROCEDURES FOR SEISMIC DESIGN OF BUILDINGS

Clarifying Frequently Misunderstood Seismic Provisions

Calculation of Wind Loads on Structures according to ASCE 7-10

Design Provisions for Earthquake Resistance of Structures. The Standards Institution of Israel

UNION STATION EXPANSION AND RESTORATION

Table 1. Detailed Comparison of Structural Provisions of 2000 IBC to 1997 NEHRP (continued)

ARCHITECTURAL ENGINEERING THE PENNSYLVANIA STATE UNIVERISITY THESIS PROJECT

DEFINITIONS AND GENERAL EQUIREMENTS

3. CLASSIFICATION AND IMPLICATIONS OF DAMAGE

Seismic Analysis of Earthquake Resistant Multi Bay Multi Storeyed 3D - RC Frame

COMPARISON OF A REINFORCED CONCRETE BUILDING STRENGTHRND WITH VARIOUS METHODS

Flexure and Serviceability Limit State

Alexis Pacella Structural Option Dr. Schneider Lexington II, Washington D.C. Technical Report #3 November 21,

Precast Concrete Bearing Wall Panel Design (Alternative Analysis Method) (Using ACI )

CE 6071 Structural Dynamics and Earthquake Engineering UNIT -5 2 MARKS

Earthquake Analysis of Multi Storied Residential Building - A Case Study

AN EXAMINATION OF DAMAGES OF REINFORCED CONCRETE CONSOLED BUILDINGS IN TURKEY DUE TO 17 AUGUST 1999 KOCAELI EARTHQUAKE

Remarks regarding FEMA 368 seismic analysis guidelines

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

midas Gen MIDAS On-Demand Service midas Gen Advanced Webinar Steel Structure Design

[Gajbe* et al., 5(7): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

MCEER Hospital Demonstration Project

Keywords: Discrete Staggered Shear Wall, High-Rise Building, Response Spectrum Analysis, Storey Drift.

Seismic Design of Building Structures

EVALUATION OF SEISMIC BEHAVIOR OF IRREGULAR STEEL STRUCTURES IN PLAN WITH BRB AND EBF BRACES UNDER NEAR-FAULT EARTHQUAKE

Dr. K. R. C. Reddy 1, Sandip A. Tupat 2 1,2

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

GENERAL CONSIDERATIONS ON STRUCTURAL REGULARITY

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

THE PLAZA AT PPL CENTER ALLENTOWN, PA

School of Engineering and Applied Science Building Miami University, Oxford, OH Technical Assignment 3 December 3, 2007

Design Example 2 Reinforced Concrete Wall with Coupling Beams

Supplemental Structural Correction Sheet Steel Brace Frame Design (2017 LABC)

r clarke 1 INTRODUCTION TO IBC SEISMIC FORCES

Comparative Study on Seismic Analysis of 20-Storeyed RC Building with Different Shear Wall Locations

STRUCTURAL SYSTEMS. Patricio BONELLI 1 SUMMARY

Supplemental Plan Check List for Concrete Special Moment Resisting Frame

COLUMNS 1- Definition: The Egyptian code defines columns as : 2- Types of concrete columns

Seismic Detailing of RC Structures (IS: )

Seismic Design of Cast-in-Place Concrete Diaphragms, Chords and Collectors

Seismic Design Principles for RC Structures

Supervisor: Eng.Ibrahim mohammad. Prepared by:

CE 549 Building Design Project Spring Semester 2010

4.6 Procedures for Connections

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 10, 2016 ISSN (online):

Lateral System Analysis and Confirmation Design

Base Shear Scaling. B. J. Davidson. Compusoft Engineering Ltd.

ISSN Vol.03,Issue.18 August-2014, Pages:

Concept of Earthquake Resistant Design

A Comparative Study on Seismic Provisions Made in UBC-1997 and Saudi Building Code for RC Buildings

Section 1 Introduction

Arlington, Virginia December 3, 2007 TECHNICAL REPORT III LATERAL SYSTEM ANALYSIS AND CONFIRMATION DESIGN

Supplemental Plan Check List for Concrete Special Moment Resisting Frame

ANALYSIS PROCEDURES FOR PERFORMANCED BASED DESIGN

Footings GENERAL CONSIDERATIONS 15.2 LOADS AND REACTIONS 15.4 MOMENT IN FOOTINGS

An-Najah National University Faculty of Engineering Civil Engineering Department Graduation Project 3D Analysis and Design of Al-Amal Hospital

CE 549 Building Design Project Spring Semester 2013

Seismic Performance Evaluation of an Existing Precast Concrete Shear Wall Building

Seismic Design of Precast Concrete Structures

Comparison of Chilean and US Seismic Design Provisions for Timber Structures

AASHTO LRFD Seismic Bridge Design. Jingsong Liu July 20, 2017

Transcription:

SEISMIC DESIGN REQUIREMENTS FOR REINFORCED CONCRETE BUILDINGS

MODEL BUILDING CODES A model building code is a document containing standardized building requirements applicable throughout the United States. The three model building codes in the United States were: the Uniform Building Code (predominant in the west), the Standard Building Code (predominant in the southeast), and the BOCA National Building Code (predominant in the northeast), were initiated between 1927 and 1950. The US Uniform Building Code was the most widely used seismic code in the world, with its last edition published in 1997. Up to the year 2000, seismic design in the United States has been based on one these three model building codes. Representatives استشارية هيئة from the three model codes formed the International Code Council (ICC) in 1994, and in April 2000, the ICC published the first edition of the International Building Code, IBC-2000. In 2003, 2006, 2009 and 2012, the second, third fourth

Initiation Of The Equivalent Static Lateral Force Method The work done after the 1908 Reggio-Messina Earthquake in Sicily by a committee appointed by the Italian government may be the origin of the equivalent static lateral force method, in which a seismic coefficient is applied to the mass of the structure, to produce the lateral force that is approximately equivalent in effect to the dynamic loading of the expected earthquake. The Japanese engineer Toshikata Sano independently developed in 1915 the idea of a lateral design force V proportional to the building s weight W. This relationship can be written as F = C W, where C is a lateral force coefficient, expressed as some percentage of gravity. The first official implementation of Sano s criterion was the specification C = 10 percent of gravity, issued as a part of the 1924 Japanese Urban Building Law Enforcement Regulations in response to the destruction caused by the great 1923 Kanto earthquake. In California, the Santa Barbara earthquake of 1925 motivated several communities to adopt codes with C as high as 20 percent of gravity.

Development Of The Equivalent Static Lateral Force Method UBC/IBC Code s UBC 1927- UBC 1946 UBC 1949- UBC 1958 UBC 1961- UBC 1973 UBC 1976- UBC 1979 UBC 1982- UBC 1985 UBC 1988- UBC 1994 UBC 1997 IBC- 2000- IBC-2012 Lateral Force F = C W F = C W V = ZKCW V = ZIKCSW V = ZIKCSW V = ZICW/Rw V = CvIW/RT V = CsW The first edition of the U.S. Uniform Building Code (UBC) was published in 1927 by the Pacific Coast building Officials (PCBO), contained an optional seismic appendix. The seismic design provisions remained in an appendix to the UBC until the publication of the 1961 UBC. In the 1997 edition of UBC the earthquake load (E) is a function of both the horizontal and vertical components of the ground motion.

Safety Concepts Structures designed in accordance with the UBC provisions should generally be able to: 1. Resist minor earthquakes without damage. 2. Resist moderate earthquakes without structural damage, but possibly some nonstructural damage. 3. Resist major earthquakes without collapse, but possibly some structural and nonstructural damage. The UBC intended that structures be designed for life-safety in the event of an earthquake with a 10-percent probability of being exceeded in 50 years. The IBC intends design for collapse prevention in a much larger earthquake, with a 2-percent probability of being exceeded in 50.

Seismic Codes Are Based On Earthquake Historical Data The 1925 Santa Barbara earthquake led to the first introduction of simple Newtonian concepts in the 1927 Uniform Building Code. As the level of knowledge and data collected increases, these equations are modified to better represent these forces. In response to the 1985 Mexico City earthquake, a fourth soil profile type,, for very deep soft soils was added to the 1988 UBC, with the factor equal to 2.0. The 1994 Northridge Earthquake resulted in addition of near-fault factor to base shear equation, and prohibition on highly irregular structures in near fault regions. Also, redundancy factor added to design forces. The 1997 UBC incorporated a number of important lessons learned from the 1994 Northridge and the 1995 Kobe earthquake, where four site coefficients use in the earlier 1994 UBC has been extended to six soil profiles, which are determined by shear wave velocity, standard penetration test, and undrained shear strength.

Detailing Requirements of ACI 318-08 Based on R1.1.1.9.1 of ACI 318-08, for UBC 1991 through 1997, Seismic Zones 0 and 1 are classified as classified as zones of low seismic risk. Thus, provisions of chapters 1 through 19 and chapter 22 are considered sufficient for structures located in these zones. Seismic Zone 2 is classified as a zone of moderate seismic risk, and zones 3 and 4 are classified as zones of high seismic risk. Structures located in these zones are to be detailed as per chapter 21 of ACI 318-08 Code. For Seismic Design Categories A and B of IBC 2000 through 2012, detailing is done according to provisions of chapters 1 through 19 and chapter 22 of ACI 318-08. Seismic Design Categories C, D, E and F are detailed as per the provisions of chapter 21. Code/Standard Level of Seismic Risk Low Moderate High IBC 2000-2012 SDC A, B SDC C SDC D, E, F UBC 1991-1997 zone 0, 1 Zone 2 Zone 3, 4

Seismic Design According To 1997 UBC The Static Lateral Force Procedure Major Changes from UBC 1994 (1) Soil Profile Types: The four Site Coefficients S 1 to S 4 of the UBC 1994, which are independent of the level of ground shaking, were expanded to six soil profile types, which are dependent on the seismic zone factors, in the 1997 UBC (S A to S F ) based on previous earthquake records. The new soil profile types were based on soil characteristics for the top 30 m of the soil. The shear wave velocity, standard penetration test and undrained shear strength are used to identify the soil profile types. (2) Structural Framing Systems: In addition to the four basic framing systems (bearing wall, building frame, moment-resisting frame, and dual), two new structural system classifications were introduced: cantilevered column systems and shear wall-frame interaction systems. (3) Load Combinations: The 1997 UBC seismic design provisions are based on strength-level design rather than service-level design. (4) Earthquake Loads: In the 1997 UBC, the earthquake load (E) is a function of both the horizontal and vertical components of the ground motion.

Structures having a flexible upper portion supported on a rigid lower portion where both portions of the structure considered separately can be classified as being regular, the average story stiffness of the lower portion is at least ten times the average stiffness of the upper portion and the period of the entire structure is not greater than 1.10 times the period of the upper portion considered as a separate structure fixed at the base. Seismic Design According To 1997 UBC The Static Lateral Force Procedure Applicability The static lateral force procedure may be used for the following structures: All structures, regular or irregular (Table A1), in Seismic Zone no. 1 (Table A-2) and in Occupancy Categories 4 and 5 (Table A-3) in Seismic Zone 2. Regular structures under 73 m in height with lateral force resistance provided by systems given in Table (A-4) except for structures located in soil profile type SF, that have a period greater than 0.70 sec. (see Table A-5 for soil profiles). Irregular structures not more than five stories or 20 m in height.

Design Base Shear, V The total design base shear in a given direction is to be determined from the following formula. The total design base shear need not exceed the following: The total design base shear shall not be less than the following:

Where V = total design lateral force or shear at the base. W = total seismic dead load In storage and warehouse occupancies, a minimum of 25 % of floor live load is to be considered. Total weight of permanent equipment is to be included. Where a partition load is used in floor design, a load of not less than 50 kg/m 2 is to be included. I = Building importance factor given in Table (A-3). Z = Seismic Zone factor, shown in Table (A-2). R = response modification factor for lateral force resisting system, shown in Table (A- 4). Ca = acceleration-dependent seismic coefficient, shown in Table (A-6). Cv= velocity-dependent seismic coefficient, shown in Table (A-7). T= elastic fundamental period of vibration, in seconds, of the structure in the direction under consideration evaluated from the following equations: For reinforced concrete moment-resisting frames, For other buildings, Design Base Shear, V (Contd.) Alternatively, for shear walls,

Design Base Shear, V (Contd.) Where hn= total height of building in meters Ac = combined effective area, in m 2, of the shear walls in the first story of the structure, given by De =the length, in meters, of each shear wall in the first story in the direction parallel to the applied forces. Ai= cross-sectional area of individual shear walls in the direction of loads in m 2

Tables And Graphs Table (A-2): Seismic zone factor Z Zone 1 2A 2B 3 4 Z 0.075 0.15 0.20 0.30 0.40 Note: The zone shall be determined from the seismic zone map (Graphs A-1 and A-2). Table (A-3):Occupancy Importance Factors Occupancy Category Seismic Importance Factor, I 1-Essential facilities 1.25 2-Hazardous facilities 1.25 3-Special occupancy structures 1.00 4-Standard occupancy structures 1.00 5-Miscellaneous متنوع structures 1.00

Tables And Graphs (Contd.) Table (A-4): Structural Systems Lateral- force resisting system description R Height limit Zones 3&4. (meters) Bearing Wall Concrete shear walls Building Frame Concrete shear walls Moment-Resisting Frame SMRF IMRF OMRF Dual Shear wall + SMRF Shear wall + IMRF Cantilevered Column Cantilevered Building column elements Shear-wall Interaction Frame 4.5 48 5.5 73 8.5 5.5 3.5 8.5 6.5 N.L ---- ---- N.L 48 2.2 10 5.5 48

Table (A-5):Soil Profiles

Table (A-6): Seismic coefficient Ca Soil Profile Type Tables And Graphs (Contd.) Seismic Zone Factor, Z Z =0.075 Z = 0.15 Z = 0.2 Z = 0.3 SA 0.06 0.12 0.16 0.24 SB 0.08 0.15 0.20 0.30 SC 0.09 0.18 0.24 0.33 SD 0.12 0.22 0.28 0.36 SE 0.19 0.30 0.34 0.36 SF See Footnote Footnote: Site-specific geotechnical investigation and dynamic response analysis shall be performed to determine seismic coefficients for soil Profile Type.

Table (A-7): Seismic coefficient Cv

Tables And Graphs (Contd.) Graph (A-1): Palestine s seismic zone factors (Source: International Handbook of Earthquake Engineering, Mario Paz)

Tables And Graphs (Contd.) Graph (A-2): Palestine s seismic zone factors (Source: Annajah National University)

Vertical Distribution of Forces Vertical Distribution of Force: The base shear which is evaluated from the following equation, is distributed over the height of the building. Where: The shear force at each story is given The overturning moment is given by

Horizontal Distribution of Forces Horizontal Distribution of Force: The design story shear in any direction, is distributed to the various elements of the lateral force-resisting system in proportion to their rigidities. Horizontal Torsional Moment: The torsional design moment at a given story is given by moment resulting from eccentricities between applied design lateral forces applied through each story s center of mass at levels above the story and the center of stiffness of the vertical elements of the story, in addition to the accidental torsion (calculated by displacing the calculated center of mass in each direction a distance equal to 5 % of the building dimension at that level perpendicular to the direction of the force under consideration). Interactions of Shear Walls with Each Other: In the following figure the slabs act as horizontal diaphragms extending between cantilever walls and they are expected to ensure that the positions of the walls, relative to each other, don't change during lateral displacement of the floors. The flexural resistance of rectangular walls with respect to their weak axes may be neglected in lateral load analysis.

Horizontal Distribution of Forces (Contd.) The distribution of the total seismic load Fx, or Fy among all cantilever walls may be approximated by the following expressions: Fix = Fix + Fix and Fiy = Fiy + Fiy Where Fix = load induced in wall by inter-story translation only, in x-direction Fiy = load induced in wall by inter-story translation only, in y-direction Fix = load induced in wall by inter-story torsion only, in x-direction Fiy = load induced in wall by inter-story torsion only, in y-direction

Horizontal Distribution of Forces (Contd.) The force resisted by wall i due to inter-story translation, in x-direction, is given by The force resisted by wall i due to inter-story translation, in y-direction, is given by The force resisted by wall i due to inter-story torsion, in x-direction, is given by The force resisted by wall i due to inter-story torsion, in y-direction, is given by Where: xi = x-coordinate of a wall w.r.t the C.R of the lateral load resisting system yi = y-coordinate of a wall w.r.t the C.R of the lateral load resisting system ex = eccentricity resulting from non-coincidence of center of gravity C.G and center of rigidity C.R, in x- direction ey= eccentricity resulting from non-coincidence of center of gravity C.G and center of rigidity C.R, in y- direction Fx = total external load to be resisted by all walls, in x-direction Fy = total external load to be resisted by all walls, in y-direction Iix = second moment of area of a wall about x-axis Iiy = second moment of area of a wall about y-axis

Classification of Structural Walls According to Chapters 2 and 21 of ACI 318-02, structural walls are defined as being walls proportioned to resist combinations of shears, moments, and axial forces induced by earthquake motions. A shear wall is a structural wall. Reinforced concrete structural walls are categorized as follows: Ordinary reinforced concrete structural walls, which are walls complying with the requirements of Chapters 1 through 18. Special reinforced concrete structural walls, which are cast-in-place walls complying with the requirements of 21.2 and 21.7 in addition to the requirements for ordinary reinforced concrete structural walls. Special Provisions For Earthquake Resistance According to Clause 1.1.8.3 of ACI 318-02, the seismic risk level of a region is regulated by the legally adopted general building code of which ACI 318-02 forms a part, or determined by local authority. According to Clauses 1.1.8.1 and 21.2.1.2 of ACI 318-02 in regions of low seismic risk, provisions of Chapter 21 are to be applied (chapters 1 through 18 are applicable). According to Clause 1.1.8.2 of ACI 318-02, in regions of moderate or high seismic risk, provisions of Chapter 21 are to be satisfied. In regions of moderate seismic risk, ordinary or special shear walls are to be used for resisting forces induced by earthquake motions as specified in Clause 21.2.1.3 of the code. According to Clause 21.2.1.4 of ACI 318-02, in regions oh high seismic risk, special structural walls complying with 21.2 through 21.10 are to be used for resisting forces induced by earthquake motions.

Classification of Moment Resisting Frames Building Frame System: Based on section 1627 of UBC-1997, it is essentially a complete space frame that provides support for gravity loads. Moment Frames: Based on ACI 2.1, 21.1 and 21.2, are defined as frames in which members and joints resist forces through flexure, shear, and axial force. Moment frames are categorized as follows: Ordinary Moment Frames: Concrete frames complying with the requirements of Chapters 1 through 18 of the ACI Code. They are used in regions of low-seismic risk. Intermediate Moment Frames: Concrete frames complying with the requirements of 21.2.2.3 and 21.12 in addition to the requirements for ordinary moment frames. They are used in regions of moderate-seismic risk. Special Moment Frames: Concrete frames complying with the requirements of 21.2 through 21.5, in addition to the requirements for ordinary moment frames. They are used in regions of moderate and high-seismic risks.

Load Combinations Loads ACI 818-02 UBC-1997 Dead (D) and Live (L) 1.2 D + 1.6 L 1.32 D + 1.1 L Dead (D), Live (L) and Earthquake (E) 1.2 D + 1.0 L + 1.0 E 1.2 D + 1.0 L + 1.1 E Earthquake Loads Based on UBC 1630.1.1, horizontal earthquake loads to be used in the above-stated load combinations are determined as follows: Where: E = earthquake load resulting from the combination of the horizontal component, and the vertical component, E h = the earthquake load due to the base shear, V E v = the load effects resulting from the vertical component of the earthquake ground motion and is equal to the addition of to the dead load effects D Ρ = redundancy factor, to increase the effects of earthquake loads on structures with few lateral force resisting elements (taken as 1.0 where z =0, 1 or 2)

Design of Ordinary Shear Walls The shear wall is designed as a cantilever beam fixed at the base, to transfer load to the foundation. Shear force, bending moment, and axial load are maximum at the base of the wall. Types of Reinforcement To control cracking, shear reinforcement is required in the horizontal and vertical directions, to resist in plane shear forces. The vertical reinforcement in the wall serves as flexural reinforcement. If large moment capacity is required, additional reinforcement can be placed at the ends of the wall within the section itself, or within enlargements at the ends. The heavily reinforced or enlarged sections are called boundary elements.

Design of Ordinary Shear Walls Shear Design According to ACI 11.1.1, nominal shear strength Vn is given as Where Vc is nominal shear strength provided by concrete and Vs is nominal shear strength provided by the reinforcement. Based on ACI 11.10.3, Vn is limited by the following equation. The shear strength provided by concrete Vc is given by any of the following equations, as applicable. h = thickness of wall d = effective depth in the direction of bending, may be taken as 0.8 lw, as stated in ACI 11.10.4 Ag = gross area of wall thickness Nu = factored axial load

Design of Ordinary Shear Walls Shear Reinforcement When the factored shear force exceeds ФVc/2, -Horizontal reinforcement ration ρh is not to be less than 0.0025. Spacing of this reinforcement S2 is not to exceed the smallest of lw/5, 3h and 45 cm. - Vertical reinforcement ratio ρn is not to be taken less than Nor 0.0025. According to ACI 11.10.9.1, when the factored shear force Vu exceeds ФVc, horizontal shear reinforcement must be provided according to the following equation. Spacing of this reinforcement S1 is not to exceed the smallest of lw/3, 3h and 45 cm. Where: Av = Area of horizontal shear reinforcement within a distance S2. Ρh = ratio of horizontal shear reinforcement area to gross concrete area of vertical section. Ρn = ratio of vertical shear reinforcement area to gross concrete area of horizontal section.

Design of Ordinary Shear Walls (Contd.) Flexural Design The wall must be designed to resist the bending moment at the base and the axial force produced by the wall weight or the vertical loads it carries. Thus, it is considered as a beam-column. For rectangular shear walls containing uniformly distributed vertical reinforcement and subjected to an axial load smaller than that producing balanced failure, the following equation, developed by Cardenas and Magura in ACI SP-36 in 1973, can be used to determine the approximate moment capacity of the wall. Where: C = distance from the extreme compression fiber to the neutral axis lw = horizontal length of wall Pu = factored axial compressive load fy = yield strength of reinforcement Ф = strength reduction factor

Design of Ordinary Shear Walls (Contd.) Reinforcement

Thank You For Your Patience!