Chicane Deceleration An Innovative Energy Contamination Control Technique in Low Energy Ion Implantation

Similar documents
Electrical Properties of Ultra Shallow p Junction on n type Si Wafer Using Decaborane Ion Implantation

Implant And Annealing Process Integration Issues To Reduce Device Variability For <10nm p+ & n+ Ultra-Shallow junctions

1. Introduction. What is implantation? Advantages

Ion Implantation Most modern devices doped using ion implanters Ionize gas sources (single +, 2+ or 3+ ionization) Accelerate dopant ions to very

CHAPTER 9: Ion Implantation

Monitoring Ion Implantation and Annealing Precision to Reduce Device Variability

Semiconductor Manufacturing Technology. Semiconductor Manufacturing Technology

Junction formation in Ge by coimplant. and pre-heating techniques

Problem 1 Lab Questions ( 20 points total)

ECE 440 Lecture 27 : Equilibrium P-N Junctions I Class Outline:

Fabrication Technology

Chapter 3 Silicon Device Fabrication Technology

Activation Behavior of Boron and Phosphorus Atoms Implanted in Polycrystalline Silicon Films by Heat Treatment at 250 C

Process Flow in Cross Sections

ELEC 3908, Physical Electronics, Lecture 4. Basic Integrated Circuit Processing

Future technologies for the electrical isolation of III-V semiconductor devices. Final report on grant no. GR/N32969 (including GR/S52797/01)

Impacts of Carbon Impurity in Plasmas on Tungsten First Wall

Introduction to Lithography

Ion Implantation Most modern devices doped using ion implanters Implant dopants by accelerating individual atoms (ions) Ionize gas sources (single +,

Advances in Optical Densitometry for Low Dose Measurements

Implant Metrology for Bonded SOI Wafers Using a Surface Photo-Voltage Technique

Wet Processing Techniques for Achieving Ultra-shallow Junctions in Future CMOS Devices

EECS130 Integrated Circuit Devices

1 INTRODUCTION 2 EXPERIMENTATION

Conformal Doping for FinFETs by Self-Regulatory Plasma Doping. 16 nm. Bell Shockley Bardeen Brattain 3. Kilby 1959 Noyce 3) MOS FET

Future technologies for electrical isolation of III-V Semiconductor devices

Design Consideration and Effect of Parameter Variation on sub-40nm Bulk MOSFET using TCAD Tool

Physical Vapor Deposition (PVD) Zheng Yang

An advantage of thin-film silicon solar cells is that they can be deposited on glass substrates and flexible substrates.

Quarterly Report EPRI Agreement W

Flash Annealing Technology for USJ: Modeling and Metrology

Deuterium retention mechanism in tungsten-coatings exposed to JT-60U divertor plasmas

Microelettronica. Planar Technology for Silicon Integrated Circuits Fabrication. 26/02/2017 A. Neviani - Microelettronica

Extended Abstracts of the Sixth International Workshop on Junction Technology

Make sure the exam paper has 9 pages total (including cover page)

Enhancement of Phosphorus Activation in Vacancy. Engineered thin Silicon-on-Insulator Substrates

EE 330 Lecture 8. IC Fabrication Technology Part II. - Oxidation - Epitaxy - Polysilicon - Interconnects

Ion-beam technology. w. K. Hofker. Depth distribution of boron ions. Experimental methods

In operandi observation of dynamic annealing: a case. Supplementary Material

EE 330 Lecture 9. IC Fabrication Technology Part 2

CHAPTER 4: Oxidation. Chapter 4 1. Oxidation of silicon is an important process in VLSI. The typical roles of SiO 2 are:

Fig.1: Comparison of various implant species energy and dose on surface amorphous layer depth.

45nm Node p+ USJ Formation With High Dopant Activation And Low Damage

Influence of low temperature preanneals on dopant and defect behavior for low energy Ge preamorphized silicon

XTEM characterization of modulated ion implantation through self-organized anodic aluminium oxide (AAO) membranes

Ion Implantation Most modern devices doped using ion implanters Implant dopants by accelerating individual atoms (ions) Ionize gas sources (single +,

CMOS Technology. Flow varies with process types & company. Start with substrate selection. N-Well CMOS Twin-Well CMOS STI

Microscopic Damage of Metals Exposed to the Helium Discharges in TRIAM-1M Tokamak and its Impact on Hydrogen Recycling Process

MOSFET. n+ poly Si. p- substrate

A discussion of crystal growth, lithography, etching, doping, and device structures is presented in

KEYWORDS: MOSFET, reverse short-channel effect, transient enhanced diffusion, arsenic, phosphorus, source, drain, ion implantation

Figure 2.3 (cont., p. 60) (e) Block diagram of Pentium 4 processor with 42 million transistors (2000). [Courtesy Intel Corporation.

EE 143 FINAL EXAM NAME C. Nguyen May 10, Signature:

Characterization and erosion of metal-containing carbon layers

Hydrogen-induced surface blistering of sample chuck materials in hydrogen plasma immersion ion implantation

Chapter 2 Problems. The CMOS technology we need to realize is shown below, from Figure 1-34 in the text. S P + N P + N WELL P +

Silver Diffusion Bonding and Layer Transfer of Lithium Niobate to Silicon

Lecture 12. Physical Vapor Deposition: Evaporation and Sputtering Reading: Chapter 12. ECE Dr. Alan Doolittle

Fabrication Process. Crystal Growth Doping Deposition Patterning Lithography Oxidation Ion Implementation CONCORDIA VLSI DESIGN LAB

Czochralski Crystal Growth

ET3034TUx High efficiency concepts of c- Si wafer based solar cells

Most semiconductor devices contain at least one junction between p-type and n-type material. These p-n junctions are fundamental to the performance

Doping fin field-effect transistor sidewalls : impurity dose retention in silicon due to high angle incident ion

Previous Lecture. Vacuum & Plasma systems for. Dry etching

A STUDY OF THE EFFECTIVENESS OF THE REMOVAL OF HYDROCARBON CONTAMINATION BY OXIDATIVE CLEANING INSIDE THE SEM.

EE40 Lec 22. IC Fabrication Technology. Prof. Nathan Cheung 11/19/2009

Abstract --- We investigated phosphorus and boon implanted emitter and selective emitter junction formation

Radiation Defects and Thermal Donors Introduced in Silicon by Hydrogen and Helium Implantation and Subsequent Annealing

HOMEWORK 4 and 5. March 15, Homework is due on Monday March 30, 2009 in Class. Answer the following questions from the Course Textbook:

Excitation and pressure effects on photoluminescence from silicon-based light emitting diode material

VLSI Technology Dr. Nandita Dasgupta Department of Electrical Engineering Indian Institute of Technology, Madras

Microstructure of Electronic Materials. Amorphous materials. Single-Crystal Material. Professor N Cheung, U.C. Berkeley

High Temperature Oxygen Out-Diffusion from the Interfacial SiOx Bond Layer in Direct Silicon Bonded (DSB) Substrates

Antimony Clustering due to High-dose Implantation

EUV optics lifetime Radiation damage, contamination, and oxidation

PROCESS FLOW AN INSIGHT INTO CMOS FABRICATION PROCESS

Hydrogen isotope retention in W irradiated by heavy ions and helium plasma

Review of CMOS Processing Technology

Simulation of the anneal of ion implanted boron emitters and the impact on the saturation current density

The Structural and Electron Field Emission Properties of Ion- Beam-Synthesised Metallic-Dielectric Nanocomposites

Metallization deposition and etching. Material mainly taken from Campbell, UCCS

Effect of fluorine implantation dose on boron thermal diffusion in silicon

Microstructure, morphology and their annealing behaviors of alumina films synthesized by ion beam assisted deposition

BLOCK COPOLYMERS ORGANIZATION AT INTERFACE

Semiconductor Technology

Copper Interconnect Technology

SOLID SOLUTION METAL ALLOYS

Influence of beryllium carbide formation on deuterium retention and release

SCREEN Thermal Products

EE 330 Lecture 9. IC Fabrication Technology Part II. -Oxidation -Epitaxy -Polysilicon -Planarization -Resistance and Capacitance in Interconnects

Characterization and control of defect states of polycrystalline silicon thin film transistor fabricated by laser crystallization

MATTHEW A. WICKHAM 5th Year Microelectronic Engineering Student Rochester Institute of Technology ABSTRACT

Ultra-Shallow Junction Formation on 3D Silicon and Germanium Device Structures by Ion Energy Decoupled Plasma Doping

EE 143 MICROFABRICATION TECHNOLOGY FALL 2014 C. Nguyen PROBLEM SET #9

The Physical Structure (NMOS)

E. Buffagni, C. Ferrari, L. Zanotti, A. Zappettini

VLSI Technology. By: Ajay Kumar Gautam

MODELLING DOPANT DIFFUSION IN POLYSILICON. S K Jones, C Hill

Graduate Student Presentations

IT/P1-20 Beryllium containing plasma interactions with ITER materials

Transcription:

Chicane Deceleration An Innovative Energy Contamination Control Technique in Low Energy Ion Implantation N. White a, J. Chen a, C. Mulcahy b, S. Biswas b, R. Gwilliam c. a Advanced Ion Beam Technology Inc., 33 Cherry Hill Drive, Danvers, MA 01923, USA b Cascade Scientific Ltd., ETC Building, Brunel Science Park, Uxbridge, Middlesex UB8 3PH, UK c Surrey Ion Beam Center, Advanced Technology Institute, University of Surrey, Guildford GU2 7XH, UK Abstract. High current beams suitable for USJ implantation were generated by Chicane Deceleration involving an s- bend to block contaminants. Implanted wafers were analyzed with 200eV O + 2 beams at 45 o to resolve the sources of dopant profile variation in fine detail. Energy contamination is essentially eliminated, but for B + channeling remains important. Unannealed X j values from 5 to 7 nm are reported for different implant species. Keywords: Ion implantation; SIMS; Boron; USJ; Energy Contamination; Deceleration. PACS: 61.72.Tt; 61.72.-y; 66.30 Jt; 66.30.Pa;85.40.Ry; 85.40.Ss. INTRODUCTION The ITRS identifies the need for sub-40nm S/D junction depths. In the case of P-MOS devices, implant process requires very shallow implants, probably optimized to control damage mechanisms, to minimize phenomena such as transient-enhanced and boron-enhanced diffusion during the anneal. Ultrashallow dopant placement (<< 10 nm) is desirable. 1 Alternatives to conventional boron implants have been developed, including implantation of decaborane 2 and octadecaborane 3 molecular ions, true gas cluster doping 4, and plasma doping. This paper describes a) a deceleration technique to deliver high current beams of boron or BF 2 at pure ultra-low energies, and b) SIMS data taken under conditions which optimize resolution of the ultrashallow dopant profiles produced with the new technique. We explore a number of effects on the resulting measured dopant profile, including the effects of SIMS parameters. We quantify energy contamination and channeling (which could lead to deep tails in the dopant profile), as well as dose and species-related effects which can modify the asimplanted profile. At this stage, annealing was not investigated. EXPERIMENTAL DETAILS Figure 1. Chicane Deceleration. Ions are retarded by a potential field which deflects left and right around obstacles. Deceleration a short distance before the implantation station of an implanter is desirable to increase the available beam current, but in most commercially available ion implanters, results in energy contamination. 5,6 We have developed an apparatus and technique for decelerating ion beams to small fractions of their original energy (from 1/3 to 1/30) while preserving a high percentage of the beam current and eliminating these high-energy contaminants. Fig. 1 shows how this technique works. Because of the obvious resemblance, it is named a Deceleration Chicane after chicanes used in motor racing. The beam is deflected through

an s-bend by an electric field which contains a strong component of deceleration. 7 Boron ion beams were decelerated from energies in the range of 4 to 10 kev down to final energies of 200eV to 1 kev. The beam of a relatively conventional beamline is first steered off axis by 5 o to direct it into the chicane. In the chicane electric fields bend it 45 o left, then 40 o right. Ions which do not at all times have the correct energy-to-charge ratio cannot be transmitted around this chicane, and they leave the beam path to the left or right, where they are carefully intercepted by beam stops angled to block forward transmission of any unwanted emitted particles, neutral or charged. Neutral atoms formed within the beam leave the beam at the first bend. Additionally, ions which are neutralized within the chicane are also blocked. Although space-charge forces are strong, they are controlled well, because the electrostatic bends are strongly focusing 9, and the focusing and defocusing forces can be balanced. Data is presented in the next section to confirm this balance. Beam currents were measured in a magnetically suppressed Faraday cup, whose field had been modeled and calculated to permit 100% transmission of 200eV boron. Dosimetry was largely manual; the desired mechanical velocity was hand-calculated and programmed. Since we are considering channeling, we also measured the angular divergence of the beam under several conditions. SIMS analyses were initially performed on pilot samples under a variety of implant and analysis conditions. The effect of using different O + 2 energies was explored, and was compared with data obtained by others. For the pilot implants we used argon preamorphization, and saw variability in the dopant background between about 1e17 and 1e18 per cc. However, RBS analysis confirmed that the material had been fully amorphous, eliminating channeling as a potential cause. The present implant matrix was designed to remove uncertainty about the background, and to be sure to resolve any deep tails present in the dopant profiles. Prime n-type wafers were used. Most wafers were given a pre-amorphization implant (PAI) of 100keV of Ge at 2E15. The high energy and dose were designed to ensure that any higher energy beam components remained in amorphous silicon, to aid interpretation. It also ensured that any end-of-range damage existing beyond the fully amorphous layer was beyond the region of interest in these measurements. Some wafers were left crystalline and were implanted at 0 o to permit axial channeling. Some implants used photoresist over 50% of the implanted surface. The effect upon the dopant profile of implanting to different doses was explored, since there was interest in observing saturation effects. RESULTS Metrology Figure 2 shows two overlaid measurements of the + same sample implanted with BF 2 at 981eV (equivalent to 200eV B), using different probe beams. Both use O + 2 at 45 o, but the energies are 200 and 750 ev. The normal velocity of the oxygen atoms is lowered by the use of molecular ions and by the 45 degree incidence, giving them a normal velocity equivalent to energies per atom of 70.7 and 265 ev respectively. Figure 2 shows that the result of analyzing these profiles with 750eV O 2 is an overestimate of depth of ~ 2 nm. We have based our conclusions on the 200eV O 2 45 o results, estimating the uncertainty in depth at 0.6nm. The data has an internal consistency of better than 0.1 nm. Concentration 1E+22 02/02/2006 1E+21 1E+20 1E+19 1E+18 1E+17 1E+16 O2 Sample 3 1E+15 0 50 100 150 200 250 300 Depth (angstroms) Sample3bX_750_200_overlay.SWF FIGURE 2. Effect of SIMS energy. Cascade Scientific BF2 891eV drift implant. Same sample analyzed by 2 techniques. Results normalized to 5.00e14 dose B: O2 200 ev 45 degrees: 5.00E14 at/cm2 B: O2 750 ev 45 degrees: 5.00E14 at/cm2 Depth resolution is ~15A better with low energy SIMS Background is higher with low energy SIMS The background level is a source of concern and uncertainty. It can be seen from Fig. 2 that the background is higher in the case of 200eV analysis than of 750eV analysis. BF + 2 produces a profile differing from the equivalent boron profile both in a substantially lower background (at about 1/3) and in a deeper peak concentration; further the amount of selfsputtering dose loss is greater. (These features are visible in fig. 4, further discussed below). The reason for the lower background is not clear, and is the subject of further study. The difference is not caused

by the presence of energy contaminants or by channeling; these mechanisms have been eliminated by careful use of controls, and will be further discussed below. The use of BF 2 + implants at 891 ev as a reference standard for 200eV boron implants is therefore invalid. The angular distribution of the boron ion beam was measured by passing the beam through a set of holes in a plate, and allowing the resulting beam to mark a target 150mm behind the holes. In this manner we confirmed that the centroid of the incident ion beam was normal to the wafer surface within about 0.3 o. The beam contained a distribution of angles about this centroid, 90% of the ions lying within about +/-2.5 o of the centroid. There was no discernible variation of incident angle across the surface of the wafer using this method. nm. The peak position of a 5.8e14 BF 2 891eV implant is deeper than that of the same dose of 200eV B, although the ion velocities are the same, but matches that of the 1.9e15 boron profile. This can be accounted for by assuming that one effect of the co-implanted fluorine atoms in the lower dose BF 2 + implant is to knock on previously implanted boron at a similar rate to primary boron ions. Above 3nm the effect of photoresist-induced pressure changes can be resolved. Above 4nm the effects of channeling can be resolved. Whereas the channeling leads to a very noticeable tail about 4nm deeper than the PAI implants, the effect of pressure dependence cannot be resolved above 10nm deep. 1E+22 Bare Si, PAI, 8e14 Bare Si, PAI, 1.4e15 Horizontal Angular spread Boron, 200eV 4 3 1E+21 1E+20 Bare Si, PAI, 1.9e15 50% Photoresist, PAI, 1.3e15 50% PR, channeled, 1.4e15 891eV BF2 6.7e14 Horizontal angle, degrees 2 1 0-30 -20-10 0 10 20 30-1 -2-3 1E+19 1E+18 1E+17 0 2 4 6 8 10 12 14 16 Depth, nm -4 Horizontal distance, mm FIGURE 3. The angular divergence of the 200eV beams measured by passing the beam through five 3mm dia. holes, drifting 150mm, and recording the beam burns on paper. Analysis Key observations The profile of each peak is well resolved. No measurement artifacts are apparent at the surface. Surface oxide was approx 1.3nm based on elapsed time since pre-amorphization, except for the channeled wafers, where oxide thickness was unknown. We can see differences in Fig. 4 in the position of the maximum concentration as a function of dose, presumably because of knock-on during implantation. For 200eV B at 8.0e14 per cm 2, the peak concentration occurs at 0.11nm deep. At 1.9e15 this increases to 0.21 FIGURE 4. All profiles 200eV B + using chicane deceleration from 6 kev, except 891eV BF 2 from 8 kev for reference. All normalized to 8.0e14 for comparison. Data is smoothed by a rolling average to reduce noise, width varying from 0.01 to 0.1 nm with depth. SIMS O 2 + 200eV 45 o. Boron currents 2.1 to 2.5 ma. BF 2 3.6 ma. Preamorphization Ge 100 kev 2e15 except where noted. Energy contamination. It was deemed impractical to obtain a valid reference sample of silicon implanted with drift-mode Boron at 200eV. The least ambiguous way to determine the level of energy contamination is to compare results from a bare wafer and from one with a 50% covering of photoresist (PR). Measurement of the actual pressure close to the wafer has little meaning since the outgassing hydrogen is a directed stream, and effective pressure in the beam is far higher than gauges will record. Dose control was based on measured beam current before the implant; the dose received by the wafer with photoresist was found to be 5% lower than the bare wafer. This can be explained

if the pressure rise in the beamline upstream of the chicane structure was high enough to increase beam neutralization by 5%. It is thus estimated that the flux of 6keV neutral boron atoms was at least 5% of the delivered 200eV boron. The projected range of 6 kev boron is 27 nm with 13 nm straggle, and the SIMS data shows no sign of such a contaminant. But Fig. 4 shows a slight shift in the profile with the photoresist present. By normalizing the two profiles to the same total dose, and subtracting the bare wafer s profile from the photoresist profile, we can look at this difference in detail. This difference is plotted in Fig. 5. We have a high quality signal extending to 6.5 nm. Beyond this depth, the noiseswamped signal changes sign several times, and no clear evidence can be extracted from it. The data indicates that the profile depth at 6.5 nm is increased by 0.25nm (i.e. to 6.75nm), by the presence of photoresist. At this depth the concentration is around 1E18 per cm 3. Shift in depth due to PR, nanometers 1 0.5 0 Noisy due to background below 1e18 0 5 10 15 Fig. 6 shows two 891eV BF 2 implants, number 24 being a drift-mode beam and number 26 using chicane deceleration from 8 kev. There is a shift in profile depth of about 0.25 nm. The background in both BF 2 + implants is 1/3 that of the 200eV B + implants. The highest contaminant energy present is clearly very small, being only tens of volts greater than the 200eV present. The mechanism by which it is formed is shown in Fig. 7. Any high-energy contaminant which can reach the wafer must be formed right at the exit of the chicane in the final region of electric field. We can estimate the magnitude. For 200eV boron, we can estimate that raising the energy by 22 ev on a bare wafer would give a profile which would fall within the observed PR profile. For 891eV BF2, raising the driftmode energy by about 98eV would give a profile falling within the chicane decel profile. 1.0E+22 1.0E+21 1.0E+20 1.0E+19 1.0E+18 29 30 24 24 - BF2 891eV PAI drift 26 - BF2 891eV PAI Chicane 27 - BF2 400eV PAI chicane 28 - BF2 400eV Channeled chicane 29 - BF2 200eV PAI Chicane 30 - BF2 200eV Channeled Chicane 26 1.0E+17 0 2 4 6 8 10 Depth, nanometers 28 FIGURE 6. BF2 implant profiles, all doses normalized to 5e14 for comparison and smoothed by a rolling average increasing from 0.01 to 0.1nm with depth The chicane is highly effective in eliminating energy contamination. The excess energy is much lower than that produced by Einzel lenses and electron suppression schemes in some systems claiming to deliver drift beams. Evaluation of a percentage energy contamination is almost impossible when the increase in energy is very slight, and has no practical value. Stating the effective maximum energy is more useful. 27-0.5 Depth, nanometers FIGURE 5. Effect of photoresist is to increase profile depth by up to 0.25nm. This is the limit of any energy contamination. FIGURE 7. Source of residual contamination. Profile Shape. Zone of possible Energy contamination We implanted 200eV boron at several doses under otherwise identical conditions, and analyzed them in one batch under identical conditions. For bare wafers, with PAI and 1.3nm oxide, we observed that the peak concentration occurred at a depth of 0.11 nm for a SIMS dose of 8.5e14, but increased to 0.22 at a dose of 1.9e15. Comparison of

the implanted doses and SIMS doses indicates loss of dopant at higher doses, reaching a relative 25% loss of dose by self-sputtering at 1.9e15. It appears that as the dose is increased, the boron is redistributed by the collision cascades of the implanted ions. Dose retention would be seriously compromised at doses above 4e15, but up to 2e15 is acceptable. The same mechanism that removes part of the dose pushes the peak concentration deeper. 891 ev BF 2 + implantation produces a profile similar to a 200eV B + implant at three times the dose, as can be seen in the figures. Presumably fluorine atoms in the molecule also displace previously implanted atoms at a similar rate to boron ions. Channeling. For 200 kev B + implants at 0 o, Fig. 4 shows that failure to pre-amorphize the substrate caused the asimplanted X j depth of dopant at a concentration of 1E18 to increase by 4 nm. More than 1% of the implant channeled to a small extent, about 0.1% contributed to this deep tail. It has been reported elsewhere 8 that tilting the substrate is ineffective at low energies in reducing channeling. For BF + 2 implants, the situation was different. We compared channeled and PAI implants at 400 and 200eV. In analyzing the results shown in Fig. 6, one should bear in mind that the effective boron energy is 90 and 45 ev respectively, while the oxygen effective energy in the SIMS is 71 ev. Therefore the resolution of the depth profile of these implants is compromised because the SIMS energy is not low enough. At 400eV the implant doses were 5e14. Channeling did produce a significant effect at this energy, probably disqualifying this energy for use without PAI. At 200 ev the implant doses were 3e14. It is striking that there is no discernible difference between the PAI and the crystalline substrates. The depth at which the concentration reaches 1E18 is about 4.6 nm. The beam current for these implants was 1.0mA, which is sufficient for 33 300mm wafers per hour using reasonable generic handling times. With no requirement for PAI this is a throughput worth consideration for production use. CONCLUSIONS We presented the Chicane deceleration technique for generating high-current ion beams (several ma) of various ions at low energies, and we present data in the range from 200eV to 1 kev. The technique produces beams with very low angular spread, dominated by the thermal physics of ion production. It virtually eliminates high-energy contaminants from the ion beam. We showed the need to use very low energy O 2 beams in the SIMS analysis, in order to avoid significant distortion of the results. We further discussed issues of control and background. We performed SIMS analyses of a number of implants using this technique, to quantify the monochromaticity of the ion beam, and elucidate the effects of channeling and saturation. We demonstrated that USJ implants using B + ions can be performed with only ~22eV energy contamination at 200eV and 2.5 ma, sufficient for >60 wph. However PAI is required. We further showed that 200eV BF + 2 implantation can give still shallower junctions, and does not require PAI implants. ACKNOWLEDGMENTS We thank Ed Petersen and Yap Han Chang for beamline operation and performing the implants, Neil Montgomery and Paul Ebblewhite of Cascade Scientific for the SIMS analyses, Chris Jeynes of Surrey University for RBS measurements. REFERENCES 1. J Chen et al, The Effects of non-chromaticity of 11 B ion beams on 11 B diffusion, Nucl. Instr. and Meth. B 237 (2005) p. 155. 2. N. Hamamoto et al., Decaborane Implantation with the Medium Current Implanter, Nucl. Instr. And Meth. B 237 (2005) p. 25. 3. Y. Kawasaki et al., Ultra-shallow junction formation by B 18 H 22 ion implantation, Nucl. Instr. And Meth. B 237 (2005) p. 443. 4. M.E. Mack, Gas Cluster Ion beams for Wafer Processing, Nucl. Instr. And Meth. B 237 (2005) p. 235. 5. US Patent 6,489,622 B1 6. US patent 6,710,358 B1 7. US patent application 2006/0113494 A1. 8. M. Foad and D. Jennings, Formation of ultra-shallow junctions by ion implantation and RTA, in Solid State Technology, December 1998. 9. O.A. Anderson, D.S.A. Goldberg, W.S. Cooper, L. Soroka, A Transverse Field Focusing (TFF) accelerator for intense ribbon beams, IEEE Trans NS-30 No. 4 (1983) p. 3215.