Quality Standard for ACR Copper Tubes in LWC

Similar documents
THERMAL SOLUTIONS HIGH FINNED TUBES GEWA-H, GEWA-HB

BUREAU OF INDIAN STANDARDS Draft Indian Standard

THERMAL SOLUTIONS MEDIUM-HIGH FINNED TUBES GEWA-D, GEWA-DW, GEWA-DS

Standard Specification for Seamless Cold-Drawn Carbon Steel Feedwater Heater Tubes 1

BIS or used as Amendment to STANDARD comments is 15 Nov. 2008

Standard Specification for General Requirements for Nickel and Nickel Alloys Seamless Pipe and Tube 1

TMK HYDRA ART INSIDE SKIVED AND ROLLER BURNISHED COLD FINISHED SEAMLESS STEEL TUBES and PISTON RODS TUBES FOR HYDRAULIC CYLINDERS

BS EN Hollow bars for machining Technical delivery conditions Non alloy and alloy steels

Issue Date: 26 June 2013

DNVGL-CP-0347 Edition May 2016

SPECIFICATION FOR COPPER AND COPPER-ALLOY SEAMLESS CONDENSER AND HEAT EXCHANGER TUBES WITH INTEGRAL FINS

Summary of Substantive Changes between the 2014 and the 2016 editions of ASTM B88, Seamless Copper Water Tube

Standard Specification for Cartridge Brass Sheet, Strip, Plate, Bar, and Disks 1

EAM :2003/05 Revision 01 21/10/2016

Aluminium Alloys for Hull Construction and Marine Structure

Composition Limits, % C Mn P S Si Cr Ni Mo Cu N

Ruby. Ruby COPPER COPPER. Products of Vietnam. Website:

SPECIFICATION FOR TITANIUM AND TITANIUM ALLOY STRIP, SHEET, AND PLATE

AEROSPACE MATERIAL SPECIFICATION

SPECIFICATION FOR NICKEL ALLOY FORGINGS

HOT ROLLED STEEL FLAT PRODUCTS FOR STRUCTURAL FORMING AND FLANGING PURPOSES SPECIFICATION (Third Revision of IS 5986)

Standard Specification for Seamless Cold-Drawn Carbon Steel Feedwater Heater Tubes 1

This document is a preview generated by EVS

HDPE Conduit Specification 2011

SPECIFICATION FOR ALUMINUM AND ALUMINUM- ALLOY DRAWN SEAMLESS TUBES FOR CONDENSERS AND HEAT EXCHANGERS

BUREAU OF INDIAN STANDARDS Draft Standard Hot dip 55% Aluminium- Zinc Alloy metallic coated steel strip & sheet (plain)

AEROSPACE MATERIAL SPECIFICATION

Government Recognized Export House OHSAS 18001:2007 ISO 14001:2004 PED Approved Company.

Standard Specification for Brass Rod, Bar, and Shapes 1

Standard Specification for Copper-Beryllium Alloy Wire 1

Standard Specification for General Requirements for Wrought Seamless Copper and Copper-Alloy Tube 1

EAM :2003/05 Revision 01 21/10/2016

XI'AN LINKUN STEEL PIPE CO., LTD

Standard Specification for Seamless and Welded Carbon and Alloy-Steel Tubes for Low-Temperature Service 1

ISO INTERNATIONAL STANDARD

ORGANISATION EUROPÉENNE POUR LA RECHERCHE NUCLÉAIRE EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH. Technical Sheet. N Ed. 1 EDMS N :

XI'AN LINKUN STEEL PIPE CO., LTD

Copper sections for various applications

TECHNICAL PRODUCT INFORMATION

SPECIFICATION #AES-222C*

SPECIFICATION FOR SEAMLESS FERRITIC ALLOY- STEEL PIPE FOR HIGH-TEMPERATURE SERVICE


Standard Specification for Seamless and Welded Austenitic Stainless Steel Feedwater Heater Tubes

Multi-gauge strip. Wieland-Werke AG, Vöhringen plant. Wieland-Werke AG, Langenberg plant. Wieland Metals Singapore (Pte.) Ltd.

SPECIFICATION FOR PRECIPITATION-HARDENING NICKEL ALLOY BARS, FORGINGS, AND FORGING STOCK FOR HIGH-TEMPERATURE SERVICE

Techniques for Detection of Surface Defects in Tubing and Pipe

Summary of Substantive Changes between the 2015a and 2017 editions of ASTM F876 Crosslinked Polyethylene (PEX) Tubing

ASTM A105/A105M-10. Standard Specification for Carbon Steel Forgings for. Piping Applications ¹

thermal solutions LOW Finned Tubes

EAM :2003/05 Revision 01 21/10/2016

ALUMINIUM ALLOY SAND AND CHILL CASTINGS Gr M

3 MODIFICATIONS TO EXISTING STANDARDS

2. TEST RECORDS: All records of tests and analysis shall be kept in suitable forms approved by the Bureau.

Tenaris produces a large dimensional range of seamless tubes in high strength steel for engineering and structural application where the critical

BUREAU OF INDIAN STANDARDS. DRAFT FOR COMMENTS ONLY (Not to be reproduced without the permission of BIS or used as an Indian Standard)

Standard Specification for Steel, Sheet, Hot Rolled, Carbon, Commercial and Structural, Produced by the Twin-Roll Casting Process 1

Standard Specification for Precipitation-Hardening Nickel Alloy Bars, Forgings, and Forging Stock for High-Temperature Service 1

Standard Specification for Seamless Brass Tube [Metric] 1

Standard Specification for Nickel-Iron-Chromium Alloy Seamless Pipe and Tube 1

Draft Indian Standard Galvanized Steel Sheets (Plain and Corrugated)- Specification (Seventh Revision of IS 277) ICS

SPECIFICATION FOR SEAMLESS AND WELDED TITANIUM AND TITANIUM ALLOY TUBES FOR CONDENSERS AND HEAT EXCHANGERS

SPECIFICATION FOR STAINLESS STEEL BARS AND SHAPES

N06600, N06601, N06603, N06690, N06693, N06025, N06045,

Standard Specification for Seamless Copper Pipe, Standard Sizes 1

UHS Ultra High-strength Seamless, Hot Rolled Hollow Sections from ISMT

Section 906. STRUCTURAL STEEL

Standard Specification for Copper and Copper Alloy Forging Rod, Bar, and Shapes 1

THERMOFIT RNF-150 TUBING Flexible, Heat-Shrinkable, Flame-Retarded Modified Fluoropolymer

Delivery formats for strip

OFFSHORE STANDARD DNV-OS-B101 METALLIC MATERIALS JANUARY 2001 DET NORSKE VERITAS

PART UF REQUIREMENTS FOR PRESSURE VESSELS FABRICATED BY FORGINGS

Standard Specification for Hot-Rolled and Cold-Finished Age-Hardening Stainless Steel Bars and Shapes 1

Weldable hot rolled ribbed steel bars A500SAS with nominal diameters of 20, 25 and 32 mm.

EAST AFRICAN STANDARD

Standard Specification for Welded Ferritic Stainless Steel Feedwater Heater Tubes 1

Standard Specification for Niobium-Hafnium Alloy Foil, Sheet, Strip, and Plate 1

isd dunaferr Product catalogue

Technical Specifications for Manufacture and Supply of 60E2 Rail R260 Grade

SPECIFICATION FOR TITANIUM AND TITANIUM ALLOY FORGINGS

SPECIFICATION FOR STAINLESS STEEL BARS AND SHAPES FOR USE IN BOILERS AND OTHER PRESSURE VESSELS

Standard Specification for Alloy Steel Forgings for Pressure and High-Temperature Parts 1

IGS-C-TP-010-Amnd2 Oct IGS. Iranian Gas Standards -(./ !" # 3 % % 2 '(!)*+ Amendment No. 2 to Three Layer Polyethylene Coating System

Standard Specification for Seamless and Welded Ferritic/Austenitic Stainless Steel Pipe

Standard Specification for Nickel-Copper Alloy (UNS N04400)* Seamless Pipe and Tube 1

DIN Seamless circular fine grain steel tubes subject to special requirements

Licensed Copy: John May, Powertrain Ltd., February 20, 2002, Uncontrolled Copy, (c) BSI

Standard Specification for Carbon and Alloy Steel Forgings for Thin-Walled Pressure Vessels 1

Standard Specification for Seamless Carbon Steel Pipe for High-Temperature Service 1

Part 2 Materials and welding Chapter 5 Special materials for naval ships

Designation: A 1011/A 1011M 07

THERMOFIT SCL TUBING Polyolefin, Selectively Crosslinked, Semirigid, Heat Shrinkable

SPECIFICATION OF LT AERIAL BUNCHED (AB) CABLES (Size: 3C x 35mm² +1C x mm²) FOR LT LINES (APPLICABLE FOR LT AB CABLE WITH XLPE INSULATION ONLY)

Requirements for bending and flaring of piping Objective, target group and warrant...3 Requirements...3 Cold Bending...4 Induction Bending...

Standard Specification for Cold-Formed Welded and Seamless Carbon Steel Structural Tubing in Rounds and Shapes 1

Licensed Copy: Sheffield University, University of Sheffield, 14 March 2003, Uncontrolled Copy, (c) BSI

Licensed Copy: Sheffield University, University of Sheffield, 25 March 2003, Uncontrolled Copy, (c) BSI

Standard Specification for Welded and Seamless Steel Pipe Piles 1

QQ-A-250F September 25, 1978 SUPERSEDING QQ-A-250E October 19, 1970 (See 6.3) FEDERAL SPECIFICATION

Copper and copper alloys Seamless, round copper tubes for medical gases or vacuum

SPECIFICATION FOR ZIRCONIUM AND ZIRCONIUM ALLOY BAR AND WIRE

Transcription:

Quality Standard for ACR Copper Tubes in LWC

Foreword cuproclima is a protected tradename for high-quality seamless copper tubes in levelwound coils (LWC) supplied to manufacturers of heat exchangers for the air conditioning and refrigeration (ACR) industry. This document describes the product requirements and delivery form of the tubes for such an end use. The specification has been established in view of the special manufacturing requirements of the ACR industry. As such it covers the main national and international standards. It should be pointed out that the cuproclima specification supports the new European Pressure Equipment Directive 97/23/EC. Of course, the production sites of Wieland-Werke AG have been certified according to DIN EN ISO 9001 : 2000 for copper tubes. The quality system of Wieland-Werke AG has been approved by the auditing company Bureau Veritas. Edition Revision Date 1 0 May 2002 1 1 June 2003

1.1 Melting and casting of round billets Tube manufacturing starts with a round billet of about 360 kg. A round billet is a cut length of cylindrical casting. In the manufacture of billets, the melting and casting process can be either in heats or continuous. 1.2 Hot extrusion of shells Shells are produced on an extrusion press by piercing and extruding the billets. For this purpose, the billets are preheated to about 900 C. To prevent the oxidation of the inner and outer surfaces of the shell, a special technique is used. 1.3 Cold working The final dimension of the tube is reached by drawing (bull blocks, spinner blocks) or combination of rolling (tube reducer) and drawing. 1.4 Level winding and eddy current testing After drawing the tubes are level wound. The eddy current tester is linked to the level winder. Whilst the tube is being level wound, it is simultaneously 100 % eddy current tested. 1.5 Annealing To achieve the final temper the tubes are annealed. The annealing is performed in a protective atmosphere (including other conditions) to eliminate oxidation and ensure a clean inside/outside surface. 1.6 Packaging After the annealing, the tubes shall be packed in such a way that damage during transport and storage is avoided. 1.7 Super clean quality On request, copper tubes are also available with particularly high inside cleanliness in the so-called super clean quality. 1.8 Quality control The purpose of quality control during the manufacturing process is to identify at the earliest possible stage any defect deleterious to the final product and to stop such material from proceeding in the process. For that purpose, the product itself, the manufacturing parameters as well as the machinery, equipment and tooling at the different stages are submitted to permanent controls as specified in the QAM and the documented procedures. 1. Description of manufacturing process and quality controls within the manufacturing process 1

2. Product specification 2.1 Scope The purpose of this specification is to define the chemical, geometrical, mechanical and other characteristics of seamless round copper tubes used in the manufacture of heat exchangers for air conditioning and refrigeration equipment and the procedures used to test these characteristics. 2.2 General statement When tubes are ordered according to this cuproclima specification, the requirements listed in items 2.3-2.7 shall apply. This specification covers among others the following standards (latest editions): ASTM B 68 C 12200 (USA) light annealed B 743 (DHP) soft annealed These tubes are supplied in LEVEL-WOUND COILS in an annealed temper and with appropriate packaging. EN 12735-2 Cu-DHP (Europe) Y040 light annealed Y035 soft annealed 2.3 Definitions Seamless tube: a tube produced with a continuous periphery at all stages of the production; Coil: a length of tube wound into a series of connected turns (without cardboard reel); Level-wound coil (LWC): a coil in which the tube is wound into layers parallel to the axis of the coils such that successive turns in a given layer are next to one another (without cardboard reel); Cardboard reel: Type of packaging for LWC made of cardboard material. To use for customers without coil adapters in decoiling operation. The term unaided eye as used in this specification means that the use of corrective spectacles to reach normal vision are permitted. 2.4 Order specification Order specification shall include the following information: Copper tubes according to cuproclima quality standard Total quantity (kg) of each item Material designation (deoxidized high residual phosphorus copper) Temper (light or soft annealed) Dimensions (outside diameter x wall thickness) Maximum coil weight Type of packing (without or with cardboard reel) Special requirements (e.g. maximum cardboard reel or coil dimensions, sealing of the tube ends, mill test certificate, etc.) Local defects: a discontinuity localised in a very short length of the tube (holes, cracks, dents, inclusions, etc.) Longitudinal defect: a non-local discontinuity which involves a certain length of the tube. 2

2.5 Specification and requirements 2.5.1 Material The tubes are made of phosphorus deoxidized copper. The chemical composition shall meet the requirements of table 2. 2.5.2 Temper Tubes are normally supplied in light annealed Y040 temper. They can also be supplied in soft annealed Y035 temper. Respective mechanical properties and grain size shall meet the requirements of table 3. 2.5.3 Dimensions and tolerances The tubes are defined by the outside diameter (d) the wall thickness (t) 2.5.3.1 Recommended sizes Cuproclima recommends the sizes in table 4. Other sizes can be supplied upon agreement. 2.5.4 Surface quality The inner and outer surfaces of the tubes shall be clean and smooth. The maximum permissible residue on the inner surface of the tube measured in specific cleanliness tests (ASTM B 743 or comparable) is 25 mg/m 2. On request, the ends of each coil shall be closed to prevent any contamination of the inner surface. 2.5.5 Mechanical integrity 2.5.5.1 Drift expanding No crack, break or tearing of the metal shall be visible to the unaided eye after a specific drift expanding test. The outside diameter of the tube shall be expanded by 40 %. 2.5.5.2 Eddy current testing After the final draw, the tubes shall be 100 % tested in an eddy current testing unit. Signals indicating possible defects on the tube surface trigger a colour marking at the point concerned for subsequent removal by the end user. The marking shall not deform the tube (usually black marks). The permissible number of black marks shall comply with the values given in table 7. This number is proportional to the coil weight. 2.5.6 Conditions of delivery 2.5.6.1 Delivery form The tubes can be delivered either in bare coils or on cardboard reels. Common range of bare coils and cardboard reel sizes are given in table 8. Precise figures for weights and dimensions are obtainable from the manufacturer. 2.5.6.2 Weight tolerance If the nominal weight of the coil is indicated in the order, no coil shall weigh less than 70 % of the nominal weight per shipment and a maximum of 20 % of the coils shall have this minimum weight. Example: Shipment of 10 LWC, nominal weight 150 kg: No coil shall weigh less than 105 kg (70 % of the nominal weight) and a maximum of 2 coils (20 % of the coils) shall weigh 105 kg. 2.5.6.3 Packing and labeling For transportation the coils are stacked on pallets one above the other. They shall be packaged in such a way that they are protected from any damage under normal transportation, storing and handling conditions. Each coil shall be provided with a label giving at least the following information in a legible and permanent form: tube dimensions coil net weight number of eddy current black marks lot identification number 3

Each pallet shall be provided with a label with at least the following information: manufacturer customer shipping address order number dimensions and temper total gross and net weight 2.6 Test procedure This item describes the testing of the final product. 2.6.1 Number of tests The number of tests on final product is given in table 9. 2.6.2 Retests Retests may be performed if only one specimen per property out of a batch of 15 tonnes maximum fails. In that case, four additional samples from different coils of the same batch shall be taken. The results on all these additional samples have to meet the requirements. Otherwise the entire batch shall be rejected. If the result of more than one specimen fails to meet the requirement for a specific property, the entire batch shall be rejected. 2.6.3 Test methods 2.6.3.1 Methods of analysis The chemical composition shall be determined by chemical or spectrographic methods according to ASTM E53, E62, E478 or ISO 1553 and ISO 4741. 2.6.3.2 Tensile test The tensile test shall be carried out according to EN 10002-1. 2.6.3.3 Grain size definition The grain size shall be determined according to the ASTM standard E112 (comparison procedure or linear intercept procedure). For quality control during the manufacturing process other appropriate methods may be used. 2.6.3.4. Cleanliness test To perform the cleanliness test according to ASTM B743 or EN 723, a section from the outside end of the coil, not less than 1.5 m long, is used. The inside of the tube is washed with a suitable solvent. The residue remaining after evaporation of the solvent shall be determined. For the routine quality control, other methods may be used. 2.6.3.5 Drift expansion test This test shall be carried out according to ISO 8493, using a conical mandrel having a 60 included angle. 2.6.3.6 Eddy current testing After the final draw, the tubes shall be passed through an eddy current testing unit adjusted to provide information on the suitability of the tube for the intended application. For this purpose, testing procedures shall detect both local and longitudinal defects. 2.6.3.6.1 Local defects Testing shall follow the procedures of ASTM Practice E 243 Item 7.1.2b or EN 1971, except for the determination of the end effect. The calibration tube used to adjust the sensitivity of the unit shall be selected from a typical production run and shall be representative of the purchase order. The artificial defects used when calibrating the unit shall be a set of three holes, each drilled radially through the tube wall in each of three successive transverse planes at 0 120 and 240 degrees (table 10, Fig. 2). The holes shall be spaced to provide signal resolution adequate for interpretation. Alternatively, a calibration tube with one hole may be used. In this case the calibration tube shall be passed through the eddy current testing unit three times at 0 120 and 240 degrees (see EN 1971 item 5). The diameters of the drilled holes are given in table 10. As an alternative, the E. C. test and calibration of the equipment shall follow the procedure of DKI-Werkstoffblatt No. 781 class A. 4

2.6.3.6.2 Longitudinal defects Longitudinal defects can be detected by summing up, in a specific tube length, a certain number of signals smaller than those defined in item 2.6.3.6.1. Calibration of the testing unit for this purpose shall be done in such a way that all defects that could be harmful to the end use, according to the manufacturer s experience, shall be detected. Other appropriate methods with the same sensitivity may be used. 2.6.3.8 Tolerances on wall thickness The wall thickness tolerances are given in table 6. The average wall thickness is defined as half of the sum of maximum and minimum wall thikkness at any cross-section of the tube. t aver = t max + t min 2 (mm) Eccentricity (mm) is defined as follows: 2.7 Mill test certificate Upon request, a mill test certificate shall be supplied identifying the shipment and giving the test results of the final product according to this specification. 2.6.3.7 Tolerances on outside diameter Tolerances on the outside diameter are given in table 5. eccentricity = t max t min 2 (mm) The average outside diameter is defined as half of the sum of any two outside diameters normal to each other in the same cross-section. d aver = d max + d min 2 (mm) The roundness tolerance refers to the deviation of the tube cross-section from the circular form. The percentage roundness is defined as follows: roundness tolerance d max d min = x 100 % d aver where: d max = maximum diameter (mm) d min = minimum diameter (mm) d aver = average diameter (mm) where: t max = maximum wall thickness (mm) t min = minimum wall thickness (mm) at any cross-section of the tube. Non-uniformity of wall thickness (%) refers to the deviation of the maximum and / or minimum wall thickness from the average wall thickness. t max t min NUWT = x 100 (%) t max + t min Note: The dimensions are determined with commercial measuring equipment. 5

Tables Table 1 Description of quality control within the manufacturing process Manufacturing Parameters to be controlled stage on product on equipment Melting and casting chemical composition dimensions quality of surface and of cut ends melting and casting temperature cooling parameters casting speed Hot extrusion Cold working Level winding including ec-testing dimensions incl. eccentricity surface quality dimensions surface quality dimensions surface quality heating parameters tool quality tool dimensions and quality lubrication tool quality quality of defect marking number of defects adjustment and proper functioning of EC and marking devices Annealing surface quality inner surface: visually on a cross cut coil or/and by cleanliness test time temperature atmosphere Packaging quality of packaging Table 2 Chemical analysis Standard Material Cu (+ Ag) % P % Bi % Pb % designation min. max. max. cuproclima CU-DHP 99.90 0.015 0.040 0.001 0.003 ASTM C 12200 99.90 0.015 0.040 EN 12735-2 CU-DHP min. 99.90 0.015 0.040 Table 3 Mechanical properties and grain size Temper proof *) Tensile Elongation Average stress, R p 0.2 strength R m A grain size N/mm 2 min. N/mm 2 min. % mm Light annealed Y040 40 90 220 45 0.015 0.035 EN 12735-2 Y040 40 90 220 40 0.015 0.040 Soft annealed **) Y035 35 80 210 48 0.030 0.060 EN 12735-2 Y035 35 80 210 40 0.030 0.060 **) R p 0.2 values are affected by test specimen preparation but shall always meet the above requirements. **) Only on special request, but wall thickness minimum 0.5 mm. 6

Table 4 Recommended sizes Wall inch.011.012.014.016.018.020.025.028 O.D. mm 0.28 0.30 0.35 0.40 0.45 0.50 0.63 0.70 inch mm 5/16 7.94 3/8 9.53 1/2 12.70 5/8 15.87 Table 5 Tolerances on outside diameter Nominal diameter range (mm) from 6.00 over 9.52 over 13.00 over 16.00 over 22.00 to 9.52 to 13.00 to 16.00 to 22.00 to 28.00 Average diameter ± 0.04 ± 0.05 ± 0.05 t 0.40 (mm) ± 0.04 ± 0.05 ± 0.08 t > 0.40 Roundness 4.0 5.0 7.0 *) t 0.40 (%) 3.5 4.0 6.0 *) *) 0.40 < t 0.70 3.0 3.5 5.0 *) *) 0.70 < t 1.00 *) *) 1.00 < t 1.20 *) *) 1.20 < t 1.50 *) *) 1.50 < t 2.00 Wall thickness range (mm) *) Upon agreement Table 6 Tolerances on wall thickness Nominal wall thickness range (mm) from 0.25 over 0.30 over 0.35 over 0.40 over 0.50 over 0.63 over 0.80 over 1.00 over 1.20 over 1.50 over 1.80 to 0.30 to 0.35 to 0.40 to 0.50 to 0.63 to 0.80 to 1.00 to 1.20 to 1.50 to 1.80 to 2.00 Max. permissible deviation at any *) point (mm) ± 0.025 ± 0.030 ± 0.030 ± 0.040 ± 0.050 ± 0.060 ± 0.070 ± 0.080 ± 0.090 ± 0.100 ± 0.110 Tolerances on average ±0.01 ±0.015 ±0.020 ±0.025 ±0.030 ±0.035 ±0.05 ±0.05 wall thickness (mm) from 6.00 to 9.52 over 9.52 to 13.00 over 13.00 to 16.00 over 16.00 to 28.00 Nominal outside diameter range (mm) *) Includes eccentricity Note: Nominal diameter x nominal wall thickness in table 6 are reference values and shall be defined upon agreement! 7

Table 7 Permissible number of eddy current black marks per coil. The number is proportional to the coil weight, reference coil weight = 100 kg. OD Wall Ø Max. number Max. number of - thickness Testhole of black black marks per marks per min. 5 t order 100 kg coil Nominal coil weight mm mm mm 100 kg 150 kg 300 kg 6.00 9.53 < 0.35 0.4 3 1.5 2.3 4.5 6.00 9.53 0.35 0.6 3 1.0 1.5 3.0 9.54 20.00 all 0.6 3 0.8 1.2 2.4 20.01 28.00 all 0.7 3 0.8 1.2 2.4 The max. number of black marks per coil is calculated on the basis of the nominal coil weights (proportional to the reference coil weight of 100 kg). The maximum number of eddy current black marks remains constant within the permissible deviation from the nominal weight. Usual nominal Permissible deviation from Max. number of black coil weights nominal weight per 1 coil marks per 1 coil kg kg WSFS 100 70 110 3 150 105 165 5 300 210 330 9 Table 8 Coil dimensions Weight Outside Inside Total Arbor hole diameter diameter width diameter OD ID W AD kg mm mm mm mm 70 150 *) max. 1,130 600 + 10 160 320 130 *) higher weights upon agreement Fig. 1 8

Table 9 Number of tests on final product Type of test Mandatory test Number of tests Tensile one per lot *) Grain size one per lot Eddy current 100 % Dimensions **) one per lot Drift expansion one per lot Cleanliness **) per lot Upon agreement Analysis ***) Hardness ***) A lot is a quantity of 2500 kg of tubes in the same temper and dimensions. ***) Constantly controlled during manufacturing process, see table 1. ***) Analysis according to E 10204 2.2. Table 10 Calibration standard for ec-testing (diameter of drilled holes) Tube outside diameter Diameter of drilled holes mm mm from 6 to 9.53 0.4 over 9.53 to 19.00 0.6 over 19 to 22 0.7 Fig. 2

WIELAND-WERKE-AG www.wieland.de 89079 Ulm, Graf-Arco-Str. 36, Germany, Tel.: +49 (0)731 944-0, Fax: +49 (0)731 944-2820 CUPROCLIMA Quality Standard of Wieland-Werke AG Tube Division 0541-04 041/06.03Gs 0,5 ler (R+G)