Strep A RapiCard InstaTest

Similar documents
SAFETY DATA SHEET Free beta-hcg EIA Test Kit. Product number: 25-FBEHU-E01 ver

SAFETY DATA SHEET Page 1/7

SAUNA MILK EUCALYPTUS

SODIUM NITRITE 1M (2N) VOLUMETRIC SOLUTION MATERIAL SAFETY DATA SHEET SDS/MSDS

SAFETY DATA SHEET NESTE LAMDA 68 ZF

SAFETY DATA SHEET NESTE PRO COOLANT BIO 50 %; NESTE PRO COOLANT BIO READY

Version 3.0 Print Date 2011/02/23 Revision Date 2011/02/ Identification of the substance/mixture and of the company/undertaking

SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifiers Product name : Ammonia Solution 25%

SAFETY DATA SHEET Patio Seal Porous Plus

Silver 1000 ppm Single Element Standard for ICP in HNO 3 MATERIAL SAFETY DATA SHEET SDS/MSDS

SAFETY DATA SHEET NESTE SITKO 68

SAFETY DATA SHEET NESTE AVORA

3-Chloro-4-Fluoropropiophenone CAS No MATERIAL SAFETY DATA SHEET SDS/MSDS

SAFETY DATA SHEET Greenline Plus Washroom Cleaner RTU

RevCare NE 100S Safety Data Sheet

SAFETY DATA SHEET CLEENOL LIQUID SANITIZER

SAFETY DATA SHEET Ilfotol

SAFETY DATA SHEET MR1 BEARD OIL

SAFETY DATA SHEET Redex AdBlue

SAFETY DATA SHEET Bleach Tablets

SAFETY DATA SHEET. In accordance with REACH Regulation EC No.1907/2006. Section 1. Identification of the substance or the mixture and of the supplier

SCANDIUM CAS NO MATERIAL SAFETY DATA SHEET SDS/MSDS

MICARE CARPET SHAMPOO DRY FOAM

SAFETY DATA SHEET POLAR BLAST

SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifiers Product name : Acid Alcohol

SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifiers Product name : Ferrous Sulphate Hydrate

SAFETY DATA SHEET. In accordance with REACH Regulation EC No.1907/2006. Section 1. Identification of the substance or the mixture and of the supplier

SAFETY DATA SHEET Savona D1

Safety Data Sheet Reduced Graphene Oxide-NH 2

SELENIC ACID CAS NO MATERIAL SAFETY DATA SHEET SDS/MSDS

Material Safety Data Sheet Maxcare Pine Disinfectant Crescent Brands

SAFETY DATA SHEET DPD XF TABLETS

STRONTIUM HYDROXIDE OCTAHYDRATE CAS No MATERIAL SAFETY DATA SHEET SDS/MSDS

: TIMOLOL FOR SYSTEM SUITABILITY CRS

MATERIAL SAFETY DATA SHEET SDS/MSDS SELIWAN OFF'S REAGENT

SAFETY DATA SHEET FIRESTOP 400 VIT

SAFETY DATA SHEET EPOCAST 36, Basis Mass

SAFETY DATA SHEET JANGRO LAUNDRY TABLETS

SAFETY DATA SHEET GEORGIAN OIL MIXING WHITE

SAFETY DATA SHEET MR1 SHAVE CREAM

SAFETY DATA SHEET Immersion Oil According to Regulation (EC) No 1907/2006, Annex II, as amended.

Safety Data Sheet Single Crystal Graphene On SiO2/Si

Safety Data Sheet Graphene Dispersion in Water

SAFETY DATA SHEET OXY POWDER

Germanium Atomic Absorption Std. Soln mg/per lit AAS in HNO 3 MATERIAL SAFETY DATA SHEET SDS/MSDS

SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifiers Product name : Holmium (III) Oxide

Benzoyl Peroxide 25% with Water CAS No MATERIAL SAFETY DATA SHEET SDS/MSDS

Version 2.0 Print Date 2011/02/08 Revision Date 2011/02/ Identification of the substance/mixture and of the company/undertaking

Antimony 1000 ppm single Element Standard for ICP in HNO 3 MATERIAL SAFETY DATA SHEET SDS/MSDS

SAFETY DATA SHEET Ecoforce Disinfection spray RTU

SAFETY DATA SHEET 5L SUPER CONCENTRATED DETERGENT LEMON

SAFETY DATA SHEET MOSS KILLER

SAFETY DATA SHEET ACCORDING TO EC-REGULATIONS 1907/2006 (REACH), 1272/2008 (CLP) & 453/2010

SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifiers Product name : m-amino Benzoic Acid

Hydrochloric Acid 0.5 M (0.5N) Volumetric Solution MATERIAL SAFETY DATA SHEET SDS/MSDS

SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifiers Product name : Cyanoacetamide

SDS/MSDS. 1.4 Emergency telephone number Emergency Phone # : (9:00am - 6:00 pm) [Office hours] SECTION 2: Hazards identification

SAFETY DATA SHEET Cutan Complete Foaming Hand Sanitiser According to Regulation (EC) No 1907/2006, Annex II, as amended by Regulation (EU) No 453/2010

Revision date: Supersedes: Version: 1.0

SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifiers Product name : Ytterbium Oxide

SECTION 3: Composition/information on ingredients

SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifiers Product name : 2-Bromo Benzoic Acid

SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifiers Product name : Aluminium Phosphate

1. Identification of the substance/mixture and of the company/undertaking

SAFETY DATA SHEET Boelube

GADOLINIUM CAS No MATERIAL SAFETY DATA SHEET SDS/MSDS

: ph Neutral Snow Foam

SAFETY DATA SHEET SUPER TFR

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 27 / 8 / 2012

QUINOLINE YELLOW CAS NO MATERIAL SAFETY DATA SHEET SDS/MSDS

SAFETY DATA SHEET ULTIFIL NL BASE

SAFETY DATA SHEET Revised edition no : 1 SDS/MSDS Date : 9 / 7 / 2013

SAFETY DATA SHEET LEATHER CLEANER

SAFETY DATA SHEET Scuba

MATERIAL SAFETY DATA SHEET SDS/MSDS

SAFETY DATA SHEET CLEENOL BACTERICIDAL FLOOR CLEANER

SAFETY DATA SHEET SUPER NON BIOLOGICAL AUTOMATIC WASHING POWDER

SAFETY DATA SHEET 750ML SUPER ANTIBACTERIAL SURFACE CLEANER

SAFETY DATA SHEET Carpet Mousse

Mercury sulfide (HgS) (cas ) MSDS

MATERIAL SAFETY DATA SHEET (MSDS)

Safety Data Sheet Ordered Mesoporous Carbon CMK-3

Calcium Chloride 1.0 M Volumetric Solution MATERIAL SAFETY DATA SHEET SDS/MSDS

SAFETY DATA SHEET Gallup XL

SAFETY DATA SHEET according to 1907/2006/EC, Article 31

MATERIAL SAFETY DATA SHEET

SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifiers Product name : m-chloro Perbenzoic Acid

SAFETY DATA SHEET PRIVATE LABEL KITCHEN CLEANER SANITIZER PLF172S SPD713

SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifiers Product name : Anisic Alcohol

SAFETY DATA SHEET CLEENOL SENSES GREEN BACTERICIDAL LIQUID SOAP -TRICLOSAN FREE

SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifiers Product name : Barritt Reagent A

1.1 Product identifiers Product Name : ACS Material Graphene Oxide S-Method (Staudenmaier Method) Brand : ACS Material LLC CAS-No.

SAFETY DATA SHEET WILKO TOILET CLEANER VIOLET & LAVENDER

SAFETY DATA SHEET ORANGE & CLOVE FRAGRANCE

1. Product and Company Identification

RHODIUM CAS NO MATERIAL SAFETY DATA SHEET SDS/MSDS

FUCHSIN BASIC CAS No MATERIAL SAFETY DATA SHEET SDS/MSDS

Safety Data Sheet. according to Regulation (EC) No 1907/2006 VITA VM 13

Formic acid, magnesiumsalt (2:1) (cas ) MSDS

Silver Nitrate 0.01M (0.01N) Volumetric Solution MATERIAL SAFETY DATA SHEET SDS/MSDS

Transcription:

DIAGNOSTIC AUTOMATION, INC. 21250 Califa St. Suite 102 and 116, Woodland Hills, CA 91367 USA Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com MATERIAL SAFETY DATA SHEET Strep A RapiCard InstaTest 1. IDENTIFICATION OF THE SUBSANCE/PREPARATION AND OF THE COMPANY NAME. Supplier: Diagnostic Automation Inc. 21250 Califa St. Suite 102 and 116 Woodland Hills, CA 91367 USA Emergency Telephone number: Please contact the regional poison Control Center. Product Name: Strep A RapiCard InstaTest Product classification: In-Vitro diagnostics Catalog No: 176550-1-44. 2. HAZARDS IDENTIFICATION DAI Code # 44 1

2.1 Classification of the substance or mixture Classification according to regulation (EC) No. 1272/2008 appendix VII: Not applicable Chemical Ingredient Chemical Data / Information Classification according to regulation 67/548/EEC or regulation 1999/45/EC: Not applicable 2.2 Labe elements Labelling according to regulation (EC) No. 1272/2008 The product does not need to be labelled in accordance with EC directives or respective national laws. Hazard picograms and Signal word: No Hazardous components for labeling: No Hazard statements: No Precautionary statements: No 2.3 Other hazards At this concentration (0.02%) of Proclin 300, this biocidal preservative is irritating to eyes and skin, and may be detrimental if enough is ingested. ProClin 300 is a skin sensitizer; prolonged or repeated exposure may cause allergic reaction in certain sensitive individuals [H317]. 3. COMPOSITION / INFORMATION ON INGREDIENTS 3.1 Substances This product is a mixture 3.2 Mixtures Hazardous ingredients Mixture of 5-Chloro-2- methyl-4-isothiazolin-3- one and 2-Methyl-2H - isothiazol-3-one (3:1) CAS No. EINECS No. REACH Registration No. Classification: Category Codes/ Hazard statement 55965-84-9 N/A Not available Acute Tox. 3: H301 H311-H331 Skin Corr. 1B: H314 Skin Sens. 1: H317 Aquatic Acute 1; H400 Aquatic Chronic 1; H410 W/W % 0.001% Lowest generic cut-off value according to Table 1.1 Annex I: 0.1 Lowest specific concentration limits according to Table 3.1 Annex VI: Skin Corr. 1B; H314 C 0.6 % Skin Irrit. 2; H315: 0,06 % C < 0.6 % Eye Irrit. 2; H319: 0,06 % C < 0.6 % Skin Sens. 1; H317: C 0.015 % 4. FIRST-AID MEASURES 4.1 Description of first aid measures After inhalation Remove person from exposure area to fresh air. If breathing becomes difficult, immediately call for emergency medical assistance. Treat symptomatically and supportively. Generally, this aqueous product is not a significant inhalation hazard in the kit volumes and concentrations present. DAI Code # 44 2

After skin contact After eye contact After Ingestion Remove contaminated clothing. Flush skin with copious water and wash affected area with soap and water. If blood-to-blood contact occurs or if more severe symptoms develop, consult a physician. Flush eyes with copious water for at least 15 minutes. Ensure adequate flushing by separating the eyelids with fingers while flushing with water. OBTAIN MEDICAL ATTENTION. If ingested, wash out mouth thoroughly with water, provided the person is conscious, and OBTAIN MEDICAL ATTENTION. Call a physician or the local poison control center. Treat symptomatically and supportively. If vomiting occurs, keep head lower than hips to prevent aspiration. 4.2 Most important symptoms and effects, both acute and delayed Not applicable. 4.3 Indication of any immediate medical attention and special treatment needed. 5. FIRE-FIGHTING MEASURES 5.1 Extinguishing media Suitable extinguishing media: The common fire extinguish media can be used Unsuitable extinguishing media: Not investigate 5.2 Special hazards arising from the substance or mixture Not find yet 5.3 Advice for fire-fighters Dry-chemical fire extinguisher 6. ACCIDENTAL RELEASE MEASURES 6.1 Personal precautions, protective equipment and emergency procedures Avoid direct contact with skin, eyes, mucous membranes and clothing by wearing appropriate lab personal protective equipment (PPE) including gloves, lab coat and eye/face protection. 6.2 Environmental precautions Avoid release to the environment. 6.3 Methods and material for containment and cleaning up Clean up with broom. 6.4 Reference to other sections Collect material and dispose of waste according to section 13. 7.1 Precautions for safe handling 7. HANDLING AND STORAGE DAI Code # 44 3

General hygiene measures: Do not eat, drink or smoke in the area where specimens and kits are handled. Wash hands after use. Contaminated clothing and protective equipment must remove before entering eating areas. 7.2 Conditions for safe storage, including any incompatibilities Information about storage conditions: Note the storage conditions on product packaging. Requirements for storage rooms and containers: Store in a cool dry place. 7.3 Specific end uses Rapid chromatographic immunoassay for the qualitative detection of Strep A antigen in human throat swab. 8. EXPOSURE CONTROLS/PERSONAL PROTCTION 8.1 Control parameters The product does not contain any relevant quantities of materials with critical values that have to be monitored in the workplace. 8.2 Exposure controls 8.2.1 Appropriate engineering controls Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday. 8.2.2 Personal protective equipment General protective and hygienic measures: Respiratory protection Protective gloves Material of gloves Penetration time of glove material Eye Protection Body protection Adhere to good laboratory practices (GLP) Wash hands before breaks and at the end of work. Not required Disposable gloves Latex/natural rubber Gloves resistance is not critical when the product is handled according to the instruction for use. Safety glasses Lab coat 8.2.3 Environmental exposure controls There are no special precautions and measures. See section 6 and 7! 9. PHYSICAL AND CHEMICAL PROPERTIES 9.1 Information on basic physical and chemical properties Physical State: Solid Colour: White appearance and some content of the test strip is purple Odours: Tasteness Odours threshold Flash point Self-igniting: Product is not known to be self-igniting DAI Code # 44 4

Danger of explosion: Melting point: Boiling point: Vapour pressure Density (20 C): ph-value at 20 C: Solubility in water: There is no substances in the kit could lead to the danger of explosion The product almost could not solute in the water 9.2 Other safety information No 10. STABILITY AND REACTIVITY 10.1 Reactivity The product is stable in accordance with the recommended storage conditions. 10.2 Chemical stability All the chemicals in the test kits are stable. 10.3 Possibility of hazardous reactions Almost impossible 10.4 Conditions to avoid High humidity and the temperature out of 2-30 10.5 Incompatible materials No 10.6 Hazardous decomposition products No 11. TOXICOLOGICAL INFORMATION 11.1 Information on toxicological effects (Mixture) Acute toxicity: Quantitative date on the toxic effects of this product is not available. Irritation Irritating to skin and severely irritating or corrosive to eyes and, with greater exposures, can cause eye damage, including permanent impairment of vision or blindness. Corrosivity Corrosive to eyes; with greater exposures may cause eye injury. Harmful if swallowed. Sensitisation Contains a small volume of a very dilute, sensitizing preservative (ProClin 300). Though the potential for an allergic response is greatly reduced by the dilution, sensitization threshold is unknown; thus, handle accordingly. Repeated dose toxicity Not yet investigate Carcinogenicity: Not yet investigate DAI Code # 44 5

Mutagenicity: Toxicity for reproduction: Not yet investigate No reproductive toxic effect known. 12. ECOLOGICAL INFORMATION 12.1 Toxicity 12.2 Persistence and degradability 12.3 Bioaccumulative potential 12.4 Mobility in soil 12.5 Results of PBT and vpvb assessment PBT/vPvB assessment not available as chemical safety assessment not required/not conducted 12.6 Other adverse effects 13. DISPOSAL CONSIDERATIONS 13.1 Waste treatment methods Product: European waste catalogue: Packaging: Chemical residues and remains should be routinely handled as special waste. This must be disposed of in compliance with anti-pollution and other laws of the country concerned. To ensure compliance we recommend that you contact the relevant (local) authorities and/or an approved waste-disposal company for information. 18 01 03 wastes whose collection and disposable is subject to special requirements in order to prevent infection. Disposal must be made in accordance with local waste management regulations. Contaminated packaging must be disposed of in the same manner as the product. Non-Contaminated packaging materials may be recycled. Contact your local service providers for further information. 14.1 UN proper shipping name ADR/RID: Not dangerous goods 14. TRANSPORT INFORMATION DAI Code # 44 6

IMDG: Not dangerous goods IATA: Not dangerous goods 14.2 Transport hazard class ADR/RID: - IMDG: - IATA: - 14.3 Packing group ADR/RID: - IMDG: - IATA: - 14.4 Environmental hazards ADR/RID / IMDG-Code / ICAO-TI / IATA-DGR: No Marine Pollutant: No 14.5 Special precautions for user See sections 6-8 14.6 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code Delivery will only be taken in suitable and regulatory approved packaging 15. REGULATORY INFORMATION 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture EU regulations: This safety data sheet complies with the requirements of Regulation (EC) No. 1907/2006. 15.2 Chemical Safety Assessment The mixture was not subjected to security assessment 16. OTHER INFORMATION General information The potential for adverse health effects is unknown for the highly diluted, small volume of ProClin 300 in this kit, but is unlikely if handled appropriately with the requisite Good Laboratory Practices and Universal Precautions. This material and its container must be disposed of in a safe way and in accordance with local, regional, national and international regulations [P501]. The information and recommendations presented in this MSDS are based on sources believed to be accurate. It is the user`s responsibility to determine the suitability of the information for their particular purposes. DAI Code # 44 7

Date Adopted 2017-09-18 176550-1-44 Strep A RapiCard TM InstaTest DIAGNOSTIC AUTOMATION, INC. 21250 Califa St. Suite 102 and 116, Woodland Hills, CA 91367 USA Tel: (818) 591-3030 Fax: (818) 591-8383 ISO 13485-2003 Version No.1 DAI Code # 44 8

DIAGNOSTIC AUTOMATION, INC. 21250 Califa St. Suite 102 and 116, Woodland Hills, CA 91367 USA Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com MATERIAL SAFETY DATA SHEET Strep A RapiCard InstaTest Extraction Reagent 1 1. IDENTIFICATION OF THE SUBSANCE/PREPARATION AND OF THE COMPANY NAME. Supplier: Diagnostic Automation Inc. 21250 Califa St. Suite 102 and 116 Woodland Hills, CA 91367 USA Emergency Telephone number: Please contact the regional poison Control Center. Product Name: Strep A RapiCard InstaTest Extraction Reagent 1 Product classification: In-Vitro diagnostics Catalog No: NA DAI Code # 44 9

. 2. HAZARDS IDENTIFICATION 2.1 Classification of the substance or mixture Classification according to regulation (EC) No. 1272/2008 appendix VII: Oxidizing solids (Category 3), H272 Acute toxicity, Oral (Category 3), H301 Eye irritation (Category 2), H319 Acute aquatic toxicity (Category 1), H400 For the full text of the H-Statements mentioned in this Section, see Section 16. Chemical Ingredient Chemical Data / Information Classification according to regulation 67/548/EEC or regulation 1999/45/EC: O Oxidising R8 T Toxic R25 N Dangerous for the environment R50 For the full text of the R-phrases mentioned in this Section, see Section 16. 2.2 Labe elements Labelling according to regulation (EC) No. 1272/2008 Labelling should be according to regulation (EC) No. 1272/2008 Hazard picograms and Signal word: Danger Hazardous components for labeling: Hazard statements: H272 May intensify fire; oxidiser. H301 Toxic if swallowed. H319 Causes serious eye irritation. H400 Very toxic to aquatic life. Precautionary statements: P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P273 Avoid release to the environment. P280 Wear protective gloves/ eye protection/ face protection. P301 + P310 + P330 IF SWALLOWED: Immediately call a POISON CENTER or doctor/ physician. Rinse mouth. P337 + P313 If eye irritation persists: Get medical advice/ attention. P391 Supplemental Hazard Statements Collect spillage. None 2.3 Other hazards This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vpvb) at levels of 0.1% or higher. DAI Code # 44 10

3. COMPOSITION / INFORMATION ON INGREDIENTS 3.1 Substances This product is a mixture 3.2 Mixtures Component CAS No. EINECS No. Classification: Conc % Sodium Nitrite 7632-00-0 231-555-9 Ox. Sol. 3; Acute Tox. 3; Eye Irrit. 2; Aquatic Acute 1; H272, H301, H319, H400 100% For the wording of the listed phrases refer to section 16 4. FIRST-AID MEASURES 4.1 Description of first aid measures After inhalation Remove person from exposure area to fresh air. If breathing becomes difficult, immediately call for emergency medical assistance. Treat symptomatically and supportively. Generally, this aqueous product is not a significant inhalation hazard in the kit volumes and concentrations present. After skin contact Can be irritating to skin, prolonged contact can be more severe, no adverse effects during normal usage. In case of skin contact, rinse area for at least 15 minutes. Remove contaminated clothes and shoes; wash thouroughly before reuse. Get immediately medical attention if irritation persists. After eye contact In case of eye contact, immediately rinse eye thouroughly with plenty of water. Remove contact lenses and continue rinsing for at least 15 minutes. Get immediate medical attention. After Ingestion If desiccant or other components are swallowed seek medical attention. 4.2 Most important symptoms and effects, both acute and delayed The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11 4.3 Indication of any immediate medical attention and special treatment needed. 5. FIRE-FIGHTING MEASURES 5.1 Extinguishing media Suitable extinguishing media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. Unsuitable extinguishing media: 5.2 Special hazards arising from the substance or mixture DAI Code # 44 11

5.3 Advice for fire-fighters Wear self-contained breathing apparatus for firefighting if necessary. 6. ACCIDENTAL RELEASE MEASURES 6.1 Personal precautions, protective equipment and emergency procedures Wear respiratory protection. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. For personal protection see section 8. 6.2 Environmental precautions Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided. 6.3 Methods and material for containment and cleaning up Absorb in vermiculite, dry sand or earth and place into containers. Flush with plenty of water to clean spillage area. 6.4 Reference to other sections Collect material and dispose of waste according to section 13. 7. HANDLING AND STORAGE 7.1 Precautions for safe handling Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Provide appropriate exhaust ventilation at places where dust is formed. Keep away from sources of ignition. No smoking. Keep away from heat and sources of ignition. For precautions see section 2.2. 7.2 Conditions for safe storage, including any incompatibilities No specific storage is required. Use shelves or cabinets sturdy enough to bear the weight of the chemicals. Be sure that it is not necessary to strain to reach materials, and that shelves are not overloaded. 7.3 Specific end uses Extract the Strep A antigen before testing. 8. EXPOSURE CONTROLS/PERSONAL PROTCTION 8.1 Control parameters The product does not contain any relevant quantities of materials with critical values that have to be monitored in the workplace. 8.2 Exposure controls 8.2.1 Appropriate engineering controls DAI Code # 44 12

Not applicable. 8.2.2 Personal protective equipment General protective and hygienic measures: Respiratory protection Protective gloves Material of gloves Penetration time of glove material Eye Protection Body protection Adhere to good laboratory practices (GLP) Wash hands before breaks and at the end of work. Not required Disposable gloves Latex/natural rubber Gloves resistance is not critical when the product is handled according to the instruction for use. Safety glasses Lab coat 8.2.3 Environmental exposure controls There are no special precautions and measures. See section 6 and 7! 9. PHYSICAL AND CHEMICAL PROPERTIES 9.1 Information on basic physical and chemical properties Physical State: Liquid Colour: Red or purple Odours: Odourless Odours threshold Flash point Self-igniting: The Product is not self-igniting Danger of explosion: Product does not present an explosion hazard Melting point: Boiling point: Vapour pressure Density (20 C): ph-value at 20 C: Solubility in water: Easy to solute in water 9.2 Other safety information Other physical-chemical date were not determined 10. STABILITY AND REACTIVITY 10.1 Reactivity The product is stable in accordance with the recommended storage conditions. 10.2 Chemical stability The product is stable in accordance with the recommended storage conditions. 10.3 Possibility of hazardous reactions None Known DAI Code # 44 13

10.4 Conditions to avoid None Know 10.5 Incompatible materials Avoid contact with strong acids, bases and strong oxidizing agents 10.6 Hazardous decomposition products None know 11. TOXICOLOGICAL INFORMATION 11.1 Information on toxicological effects (Mixture) Acute toxicity: Quantitative date on the toxic effects of this product is not available. Irritation Irritating to skin and severely irritating or corrosive to eyes and, with greater exposures, can cause eye damage, including permanent impairment of vision or blindness. Corrosivity Not applicable Sensitisation Not applicable Repeated dose toxicity Not applicable Carcinogenicity: The concentration of Sodium Nitrite in this product is 2M. No carcinogenic materials are contained. Mutagenicity: Not applicable Toxicity for reproduction: Not applicable 12. ECOLOGICAL INFORMATION 12.1 Toxicity Toxicity of products of Biodegradation: The products of degradation are toxic 12.2 Persistence and degradability Possibility hazardous short term degradation products are not likely. Long term degradation products may arise. The products of degradation are toxic. 12.3 Bioaccumulative potential 12.4 Mobility in soil 12.5 Results of PBT and vpvb assessment PBT/vPvB assessment not available as chemical safety assessment not required/not conducted 12.6 Other adverse effects DAI Code # 44 14

13. DISPOSAL CONSIDERATIONS 13.1 Waste treatment methods Product: European waste catalogue: Packaging: General information Chemical residues and remains should be routinely handled as special waste. This must be disposed of in compliance with anti-pollution and other laws of the country concerned. To ensure compliance we recommend that you contact the relevant (local) authorities and/or an approved waste-disposal company for information. 18 01 03 wastes whose collection and disposable is subject to special requirements in order to prevent infection. Disposal must be made in accordance with local waste management regulations. Contaminated packaging must be disposed of in the same manner as the product. Non-Contaminated packaging materials may be recycled. Contact your local service providers for further information. Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste disposal facility. Processing, use or contamination of this product may chage the waster management options State and local disposal regulations may differ from federal disposal regulations. Dispose of container and unused contents in accordance with federal, state and local requirements. 14.1 UN proper shipping name ADR/RID: Not dangerous goods IMDG: Not dangerous goods IATA: Not dangerous goods 14.2 Transport hazard class ADR/RID: - IMDG: - IATA: - 14.3 Packing group ADR/RID: - IMDG: - IATA: - 14.4 Environmental hazards ADR/RID / IMDG-Code / ICAO-TI / IATA-DGR: No Marine Pollutant: No 14.5 Special precautions for user See sections 6-8 14. TRANSPORT INFORMATION DAI Code # 44 15

14.6 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code Delivery will only be taken in suitable and regulatory approved packaging 15. REGULATORY INFORMATION 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture EU regulations: Not application National regulation (Germany): Not application 15.2 Chemical Safety Assessment The mixture was not subjected to security assessment 16. OTHER INFORMATION General information The information and recommendations presented in this MSDS are based on sources believed to be accurate. It is the user`s responsibility to determine the suitability of the information for their particular purposes. Hazard Statement Acute Tox. Acute toxicity Aquatic Acute Acute aquatic toxicity Eye Irrit. Eye irritation H272 May intensify fire; oxidiser. H301 Toxic if swallowed. H319 Causes serious eye irritation. H400 Very toxic to aquatic life. Ox. Sol. Oxidizing solids Risk phrases R28 very toxic if swallowed R32 contact with acids liberates very toxic gas R50/53 very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment R60 May impair fertility R61 May cause harm to the unborn child Date Adopted 2017-09-18 Strep A RapiCard TM NA InstaTest Extration Reagent 1 DAI Code # 44 16

DIAGNOSTIC AUTOMATION, INC. 21250 Califa St. Suite 102 and 116, Woodland Hills, CA 91367 USA Tel: (818) 591-3030 Fax: (818) 591-8383 ISO 13485-2003 Version No.1 DAI Code # 44 17

DIAGNOSTIC AUTOMATION, INC. 21250 Califa St. Suite 102 and 116, Woodland Hills, CA 91367 USA Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com MATERIAL SAFETY DATA SHEET Strep A RapiCard InstaTest Extraction Reagent 2 1. IDENTIFICATION OF THE SUBSANCE/PREPARATION AND OF THE COMPANY NAME. Supplier: Diagnostic Automation Inc. 21250 Califa St. Suite 102 and 116 Woodland Hills, CA 91367 USA Emergency Telephone number: Please contact the regional poison Control Center. Product Name: Strep A RapiCard InstaTest Extraction Reagent 2 Product classification: In-Vitro diagnostics Catalog No: NA DAI Code # 44 18

. 2. HAZARDS IDENTIFICATION 2.1 Classification of the substance or mixture Classification according to regulation (EC) No. 1272/2008 appendix VII: Not applicable Chemical Ingredient Chemical Data / Information Classification according to regulation 67/548/EEC or regulation 1999/45/EC: Not applicable 2.2 Labe elements Labelling according to regulation (EC) No. 1272/2008: Not applicable Hazard picograms and Signal word: Not applicable Hazardous components for labeling Hazard statements: Not applicable Precautionary statements: Not applicable 2.3 Other hazards No 3. COMPOSITION / INFORMATION ON INGREDIENTS 3.1 Substances This product is a mixture 3.2 Mixtures Component CAS No. EINECS No. Classification: Conc % Citric acid 77-92-9 201-069-1 Eye Irrit. 2; H319 100% For the wording of the listed phrases refer to section 16 4. FIRST-AID MEASURES 4.1 Description of first aid measures After inhalation Remove person from exposure area to fresh air. If breathing becomes difficult, immediately call for emergency medical assistance. Treat symptomatically and supportively. Generally, this aqueous product is not a significant inhalation hazard in the kit volumes and concentrations present. After skin contact Can be irritating to skin, prolonged contact can be more severe, no adverse effects during normal usage. In case of skin contact, rinse area for at least 15 minutes. Remove contaminated clothes and shoes; wash thouroughly before reuse. Get immediately medical attention if irritation persists. After eye contact In case of eye contact, immediately rinse eye thouroughly with plenty of water. Remove contact lenses and continue rinsing for at least 15 minutes. Get immediate medical attention. After Ingestion If desiccant or other components are swallowed seek medical attention. DAI Code # 44 19

4.2 Most important symptoms and effects, both acute and delayed Not applicable 4.3 Indication of any immediate medical attention and special treatment needed. 5. FIRE-FIGHTING MEASURES 5.1 Extinguishing media Suitable extinguishing media: No special fire-fighting procedure require Unsuitable extinguishing media: Use fire-extinguishing methods suitable to surrounding conditions 5.2 Special hazards arising from the substance or mixture Not find yet 5.3 Advice for fire-fighters No specific procedure. 6. ACCIDENTAL RELEASE MEASURES 6.1 Personal precautions, protective equipment and emergency procedures Refer to Section 8 for protective measures when handling the spillage. 6.2 Environmental precautions Avoid release to the environment. 6.3 Methods and material for containment and cleaning up Absorb in vermiculite, dry sand or earth and place into containers. Flush with plenty of water to clean spillage area. 6.4 Reference to other sections Collect material and dispose of waste according to section 13. 7. HANDLING AND STORAGE 7.1 Precautions for safe handling Do not ingest. Do not breathe dust. Wear suitable protective clothing if ingested, seek medical advice immediately and show the container or the label. Avoid contact with skin and eyes keep away from incompatibles such as oxidizing agents. 7.2 Conditions for safe storage, including any incompatibilities No specific storage is required. Use shelves or cabinets sturdy enough to bear the weight of the chemicals. Be sure that it is not necessary to strain to reach materials, and that shelves are not overloaded. 7.3 Specific end uses DAI Code # 44 20

Extract the Strep A antigen before testing. 8. EXPOSURE CONTROLS/PERSONAL PROTCTION 8.1 Control parameters The product does not contain any relevant quantities of materials with critical values that have to be monitored in the workplace. 8.2 Exposure controls 8.2.1 Appropriate engineering controls Not applicable. 8.2.2 Personal protective equipment General protective and hygienic measures: Respiratory protection Protective gloves Material of gloves Penetration time of glove material Eye Protection Body protection Adhere to good laboratory practices (GLP) Wash hands before breaks and at the end of work. Not required Disposable gloves Latex/natural rubber Gloves resistance is not critical when the product is handled according to the instruction for use. Safety glasses Lab coat 8.2.3 Environmental exposure controls There are no special precautions and measures. See section 6 and 7! 9. PHYSICAL AND CHEMICAL PROPERTIES 9.1 Information on basic physical and chemical properties Physical State: Liquid Colour: Colorless Odours: Odourless Odours threshold Flash point Self-igniting: The Product is not self-igniting Danger of explosion: Product does not present an explosion hazard Melting point: Boiling point: Vapour pressure Density (20 C): ph-value at 20 C: Solubility in water: Easy to solute in water 9.2 Other safety information Other physical-chemical date were not determined DAI Code # 44 21

10. STABILITY AND REACTIVITY 10.1 Reactivity The product is stable in accordance with the recommended storage conditions. 10.2 Chemical stability The product is stable in accordance with the recommended storage conditions. 10.3 Possibility of hazardous reactions None Known 10.4 Conditions to avoid None Know 10.5 Incompatible materials Avoid contact with strong acids, bases and strong oxidizing agents 10.6 Hazardous decomposition products None know 11. TOXICOLOGICAL INFORMATION 11.1 Information on toxicological effects (Mixture) Acute toxicity: Quantitative date on the toxic effects of this product is not available. Irritation Irritating to skin and severely irritating or corrosive to eyes and, with greater exposures, can cause eye damage, including permanent impairment of vision or blindness. Corrosivity Not applicable Sensitisation Not applicable Repeated dose toxicity Not applicable Carcinogenicity: The concentration of Citric acid in this product is 0.027M. No carcinogenic materials are contained within this product. Mutagenicity: Not applicable Toxicity for reproduction: Not applicable 12. ECOLOGICAL INFORMATION 12.1 Toxicity Toxicity of products of Biodegradation: The products of degradation are toxic 12.2 Persistence and degradability Possibility hazardous short term degradation products are not likely. Long term degradation products may arise. The products of degradation are toxic. DAI Code # 44 22

12.3 Bioaccumulative potential 12.4 Mobility in soil 12.5 Results of PBT and vpvb assessment PBT/vPvB assessment not available as chemical safety assessment not required/not conducted 12.6 Other adverse effects 13. DISPOSAL CONSIDERATIONS 13.1 Waste treatment methods Product: European waste catalogue: Packaging: General information Chemical residues and remains should be routinely handled as special waste. This must be disposed of in compliance with anti-pollution and other laws of the country concerned. To ensure compliance we recommend that you contact the relevant (local) authorities and/or an approved waste-disposal company for information. 18 01 03 wastes whose collection and disposable is subject to special requirements in order to prevent infection. Disposal must be made in accordance with local waste management regulations. Contaminated packaging must be disposed of in the same manner as the product. Non-Contaminated packaging materials may be recycled. Contact your local service providers for further information. Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste disposal facility. Processing, use or contamination of this product may chage the waster management options State and local disposal regulations may differ from federal disposal regulations. Dispose of container and unused contents in accordance with federal, state and local requirements. 14.1 UN proper shipping name ADR/RID: Not dangerous goods IMDG: Not dangerous goods IATA: Not dangerous goods 14. TRANSPORT INFORMATION DAI Code # 44 23

14.2 Transport hazard class ADR/RID: - IMDG: - IATA: - 14.3 Packing group ADR/RID: - IMDG: - IATA: - 14.4 Environmental hazards ADR/RID / IMDG-Code / ICAO-TI / IATA-DGR: No Marine Pollutant: No 14.5 Special precautions for user See sections 6-8 14.6 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code Delivery will only be taken in suitable and regulatory approved packaging 15. REGULATORY INFORMATION 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture EU regulations: Not application National regulation (Germany): Not application 15.2 Chemical Safety Assessment The mixture was not subjected to security assessment 16. OTHER INFORMATION General information The information and recommendations presented in this MSDS are based on sources believed to be accurate. It is the user`s responsibility to determine the suitability of the information for their particular purposes. Date Adopted 2017-09-18 Strep A RapiCard TM NA InstaTest Extraction Reagent 2 DAI Code # 44 24

DIAGNOSTIC AUTOMATION, INC. 21250 Califa St. Suite 102 and 116, Woodland Hills, CA 91367 USA Tel: (818) 591-3030 Fax: (818) 591-8383 ISO 13485-2003 Version No.1 DAI Code # 44 25

DIAGNOSTIC AUTOMATION, INC. 21250 Califa St. Suite 102 and 116, Woodland Hills, CA 91367 USA Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com MATERIAL SAFETY DATA SHEET Strep A RapiCard InstaTest Positive Control 1. IDENTIFICATION OF THE SUBSANCE/PREPARATION AND OF THE COMPANY NAME. Supplier: Diagnostic Automation Inc. 21250 Califa St. Suite 102 and 116 Woodland Hills, CA 91367 USA Emergency Telephone number: Please contact the regional poison Control Center. Product Name: Strep A RapiCard InstaTest Positive Control Product classification: In-Vitro diagnostics Catalog No: NA DAI Code # 44 26

. 2. HAZARDS IDENTIFICATION 2.1 Classification of the substance or mixture Classification according to regulation (EC) No. 1272/2008 appendix VII: Not applicable Chemical Ingredient Chemical Data / Information Classification according to regulation 67/548/EEC or regulation 1999/45/EC: Not applicable 2.2 Labe elements Labelling according to regulation (EC) No. 1272/2008: The product does not need to be labelled in accordance with EC directives or respective national laws. Hazard picograms and Signal word: No Hazardous components for labeling: No Hazard statements: No Precautionary statements: No 2.3 Other hazards At this concentration (0.02%) of Proclin 300, this biocidal preservative is irritating to eyes and skin, and may be detrimental if enough is ingested. ProClin 300 is a skin sensitizer; prolonged or repeated exposure may cause allergic reaction in certain sensitive individuals [H317]. 3. COMPOSITION / INFORMATION ON INGREDIENTS 3.1 Substances This product is a mixture 3.2 Mixtures Hazardous ingredients Mixture of 5-Chloro-2- methyl-4-isothiazolin-3- one and 2-Methyl-2H - isothiazol-3-one (3:1) CAS No. EINECS No. REACH Registration No. Classification: Category Codes/ Hazard statement 55965-84-9 N/A Not available Acute Tox. 3: H301 H311-H331 Skin Corr. 1B: H314 Skin Sens. 1: H317 Aquatic Acute 1; H400 Aquatic Chronic 1; H410 W/W % <0.001% Lowest generic cut-off value according to Table 1.1 Annex I: 0.1 Lowest specific concentration limits according to Table 3.1 Annex VI: Skin Corr. 1B; H314 C 0.6 % Skin Irrit. 2; H315: 0,06 % C < 0.6 % Eye Irrit. 2; H319: 0,06 % C < 0.6 % Skin Sens. 1; H317: C 0.0015 % 4.1 Description of first aid measures 4. FIRST-AID MEASURES DAI Code # 44 27

After inhalation After skin contact After eye contact After Ingestion Remove person from exposure area to fresh air. If breathing becomes difficult, immediately call for emergency medical assistance. Treat symptomatically and supportively. Generally, this aqueous product is not a significant inhalation hazard in the kit volumes and concentrations present. Remove contaminated clothing. Flush skin with copious water and wash affected area with soap and water. If blood-to-blood contact occurs or if more severe symptoms develop, consult a physician. Flush eyes with copious water for at least 15 minutes. Ensure adequate flushing by separating the eyelids with fingers while flushing with water. OBTAIN MEDICAL ATTENTION. If ingested, wash out mouth thoroughly with water, provided the person is conscious, and OBTAIN MEDICAL ATTENTION. Call a physician or the local poison control center. Treat symptomatically and supportively. If vomiting occurs, keep head lower than hips to prevent aspiration. 4.2 Most important symptoms and effects, both acute and delayed Not applicable 4.3 Indication of any immediate medical attention and special treatment needed. 5. FIRE-FIGHTING MEASURES 5.1 Extinguishing media Suitable extinguishing media: The common fire extinguish media can be used Unsuitable extinguishing media: Not investigate 5.2 Special hazards arising from the substance or mixture Not find yet 5.3 Advice for fire-fighters Dry-chemical fire extinguisher 6. ACCIDENTAL RELEASE MEASURES 6.1 Personal precautions, protective equipment and emergency procedures Avoid direct contact with skin, eyes, mucous membranes and clothing by wearing appropriate lab personal protective equipment (PPE) including gloves, lab coat and eye/face protection. 6.2 Environmental precautions Avoid release to the environment. 6.3 Methods and material for containment and cleaning up Absorb in vermiculite, dry sand or earth and place into containers. Flush with plenty of water to clean spillage area. 6.4 Reference to other sections DAI Code # 44 28

Collect material and dispose of waste according to section 13. 7. HANDLING AND STORAGE 7.1 Precautions for safe handling General hygiene measures: Do not eat, drink or smoke in the area where specimens and kits are handled. Wash hands after use. Contaminated clothing and protective equipment must remove before entering eating areas. 7.2 Conditions for safe storage, including any incompatibilities Information about storage conditions: Note the storage conditions on product packaging. Requirements for storage rooms and containers: Store in a cool dry place. 7.3 Specific end uses As the external control for the Strep A Rapid Test. 8. EXPOSURE CONTROLS/PERSONAL PROTCTION 8.1 Control parameters The product does not contain any relevant quantities of materials with critical values that have to be monitored in the workplace. 8.2 Exposure controls 8.2.1 Appropriate engineering controls Not applicable. 8.2.2 Personal protective equipment General protective and hygienic measures: Respiratory protection Protective gloves Material of gloves Penetration time of glove material Eye Protection Body protection Adhere to good laboratory practices (GLP) Wash hands before breaks and at the end of work. Not required Disposable gloves Latex/natural rubber Gloves resistance is not critical when the product is handled according to the instruction for use. Safety glasses Lab coat 8.2.3 Environmental exposure controls There are no special precautions and measures. See section 6 and 7! 9. PHYSICAL AND CHEMICAL PROPERTIES 9.1 Information on basic physical and chemical properties Physical State: Liquid DAI Code # 44 29

Colour: Odours: Odours threshold Flash point Self-igniting: Danger of explosion: Melting point: Boiling point: Vapour pressure Density (20 C): ph-value at 20 C: Solubility in water: Colorless Odourless The Product is not self-igniting Product does not present an explosion hazard The product could solute in water easily 9.2 Other safety information No 10. STABILITY AND REACTIVITY 10.1 Reactivity The product is stable in accordance with the recommended storage conditions. 10.2 Chemical stability All the chemicals in the test kits are stable. 10.3 Possibility of hazardous reactions Almost impossible 10.4 Conditions to avoid Temperature out of 2-30 10.5 Incompatible materials No 10.6 Hazardous decomposition products No 11. TOXICOLOGICAL INFORMATION 11.1 Information on toxicological effects (Mixture) Acute toxicity: Quantitative date on the toxic effects of this product is not available. Irritation Irritating to skin and severely irritating or corrosive to eyes and, with greater exposures, can cause eye damage, including permanent impairment of vision or blindness. Corrosivity Corrosive to eyes; with greater exposures may cause eye injury. Harmful if swallowed. Sensitisation Contains a small volume of a very dilute, sensitizing preservative DAI Code # 44 30

Repeated dose toxicity Carcinogenicity: Mutagenicity: Toxicity for reproduction: (ProClin 300). Though the potential for an allergic response is greatly reduced by the dilution, sensitization threshold is unknown; thus, handle accordingly. Not yet investigate Not yet investigate. Not yet investigate No reproductive toxic effect known. 12. ECOLOGICAL INFORMATION 12.1 Toxicity 12.2 Persistence and degradability 12.3 Bioaccumulative potential 12.4 Mobility in soil 12.5 Results of PBT and vpvb assessment PBT/vPvB assessment not available as chemical safety assessment not required/not conducted 12.6 Other adverse effects 13. DISPOSAL CONSIDERATIONS 13.1 Waste treatment methods Product: European waste catalogue: Packaging: Chemical residues and remains should be routinely handled as special waste. This must be disposed of in compliance with anti-pollution and other laws of the country concerned. To ensure compliance we recommend that you contact the relevant (local) authorities and/or an approved waste-disposal company for information. 18 01 03 wastes whose collection and disposable is subject to special requirements in order to prevent infection. Disposal must be made in accordance with local waste management regulations. Contaminated packaging must be disposed of in the same manner as the product. Non-Contaminated packaging materials may be recycled. Contact your local service providers for further information. DAI Code # 44 31

14.1 UN proper shipping name ADR/RID: Not dangerous goods IMDG: Not dangerous goods IATA: Not dangerous goods 14.2 Transport hazard class ADR/RID: - IMDG: - IATA: - 14.3 Packing group ADR/RID: - IMDG: - IATA: - 14.4 Environmental hazards ADR/RID / IMDG-Code / ICAO-TI / IATA-DGR: No Marine Pollutant: No 14.5 Special precautions for user See sections 6-8 14. TRANSPORT INFORMATION 14.6 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code Delivery will only be taken in suitable and regulatory approved packaging 15. REGULATORY INFORMATION 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture EU regulations: This safety data sheet complies with the requirements of Regulation (EC) No. 1907/2006 15.2 Chemical Safety Assessment The mixture was not subjected to security assessment 16. OTHER INFORMATION General information The information and recommendations presented in this MSDS are based on sources believed to be accurate. It is the user`s responsibility to determine the suitability of the information for their particular purposes. DAI Code # 44 32

Date Adopted 2017-09-18 Strep A RapiCard TM NA InstaTest Positive Control DIAGNOSTIC AUTOMATION, INC. 21250 Califa St. Suite 102 and 116, Woodland Hills, CA 91367 USA Tel: (818) 591-3030 Fax: (818) 591-8383 ISO 13485-2003 Version No.1 DAI Code # 44 33

DIAGNOSTIC AUTOMATION, INC. 21250 Califa St. Suite 102 and 116, Woodland Hills, CA 91367 USA Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com MATERIAL SAFETY DATA SHEET Strep A RapiCard InstaTest Negative Control 1. IDENTIFICATION OF THE SUBSANCE/PREPARATION AND OF THE COMPANY NAME. Supplier: Diagnostic Automation Inc. 21250 Califa St. Suite 102 and 116 Woodland Hills, CA 91367 USA Emergency Telephone number: Please contact the regional poison Control Center. Product Name: Strep A RapiCard InstaTest Negative Control Product classification: In-Vitro diagnostics Catalog No: NA DAI Code # 44 34

. 2. HAZARDS IDENTIFICATION 2.1 Classification of the substance or mixture Classification according to regulation (EC) No. 1272/2008 appendix VII: Not applicable Chemical Ingredient Chemical Data / Information Classification according to regulation 67/548/EEC or regulation 1999/45/EC: Not applicable 2.2 Labe elements Labelling according to regulation (EC) No. 1272/2008: The product does not need to be labelled in accordance with EC directives or respective national laws. Hazard picograms and Signal word: No Hazardous components for labeling: No Hazard statements: No Precautionary statements: No 2.3 Other hazards At this concentration (0.02%) of Proclin 300, this biocidal preservative is irritating to eyes and skin, and may be detrimental if enough is ingested. ProClin 300 is a skin sensitizer; prolonged or repeated exposure may cause allergic reaction in certain sensitive individuals [H317]. 3. COMPOSITION / INFORMATION ON INGREDIENTS 3.1 Substances This product is a mixture 3.2 Mixtures Hazardous ingredients Mixture of 5-Chloro-2- methyl-4-isothiazolin-3- one and 2-Methyl-2H - isothiazol-3-one (3:1) CAS No. EINECS No. REACH Registration No. Classification: Category Codes/ Hazard statement 55965-84-9 N/A Not available Acute Tox. 3: H301 H311-H331 Skin Corr. 1B: H314 Skin Sens. 1: H317 Aquatic Acute 1; H400 Aquatic Chronic 1; H410 W/W % <0.001% Lowest generic cut-off value according to Table 1.1 Annex I: 0.1 Lowest specific concentration limits according to Table 3.1 Annex VI: Skin Corr. 1B; H314 C 0.6 % Skin Irrit. 2; H315: 0,06 % C < 0.6 % Eye Irrit. 2; H319: 0,06 % C < 0.6 % Skin Sens. 1; H317: C 0.0015 % 4.1 Description of first aid measures 4. FIRST-AID MEASURES DAI Code # 44 35

After inhalation After skin contact After eye contact After Ingestion Remove person from exposure area to fresh air. If breathing becomes difficult, immediately call for emergency medical assistance. Treat symptomatically and supportively. Generally, this aqueous product is not a significant inhalation hazard in the kit volumes and concentrations present. Remove contaminated clothing. Flush skin with copious water and wash affected area with soap and water. If blood-to-blood contact occurs or if more severe symptoms develop, consult a physician. Flush eyes with copious water for at least 15 minutes. Ensure adequate flushing by separating the eyelids with fingers while flushing with water. OBTAIN MEDICAL ATTENTION. If ingested, wash out mouth thoroughly with water, provided the person is conscious, and OBTAIN MEDICAL ATTENTION. Call a physician or the local poison control center. Treat symptomatically and supportively. If vomiting occurs, keep head lower than hips to prevent aspiration. 4.2 Most important symptoms and effects, both acute and delayed Not applicable 4.3 Indication of any immediate medical attention and special treatment needed. 5. FIRE-FIGHTING MEASURES 5.1 Extinguishing media Suitable extinguishing media: The common fire extinguish media can be used Unsuitable extinguishing media: Not investigate 5.2 Special hazards arising from the substance or mixture Not find yet 5.3 Advice for fire-fighters Dry-chemical fire extinguisher 6. ACCIDENTAL RELEASE MEASURES 6.1 Personal precautions, protective equipment and emergency procedures Avoid direct contact with skin, eyes, mucous membranes and clothing by wearing appropriate lab personal protective equipment (PPE) including gloves, lab coat and eye/face protection. 6.2 Environmental precautions Avoid release to the environment. 6.3 Methods and material for containment and cleaning up Absorb in vermiculite, dry sand or earth and place into containers. Flush with plenty of water to clean spillage area. 6.4 Reference to other sections DAI Code # 44 36

Collect material and dispose of waste according to section 13. 7. HANDLING AND STORAGE 7.1 Precautions for safe handling General hygiene measures: Do not eat, drink or smoke in the area where specimens and kits are handled. Wash hands after use. Contaminated clothing and protective equipment must remove before entering eating areas. 7.2 Conditions for safe storage, including any incompatibilities Information about storage conditions: Note the storage conditions on product packaging. Requirements for storage rooms and containers: Store in a cool dry place. 7.3 Specific end uses As the external control for the Strep A Rapid Test. 8. EXPOSURE CONTROLS/PERSONAL PROTCTION 8.1 Control parameters The product does not contain any relevant quantities of materials with critical values that have to be monitored in the workplace. 8.2 Exposure controls 8.2.1 Appropriate engineering controls Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday. 8.2.2 Personal protective equipment General protective and hygienic measures: Respiratory protection Protective gloves Material of gloves Penetration time of glove material Eye Protection Body protection Adhere to good laboratory practices (GLP) Wash hands before breaks and at the end of work. Not required Disposable gloves Latex/natural rubber Gloves resistance is not critical when the product is handled according to the instruction for use. Safety glasses Lab coat 8.2.3 Environmental exposure controls There are no special precautions and measures. See section 6 and 7! 9. PHYSICAL AND CHEMICAL PROPERTIES 9.1 Information on basic physical and chemical properties DAI Code # 44 37

Physical State: Colour: Odours: Odours threshold Flash point Self-igniting: Danger of explosion: Melting point: Boiling point: Vapour pressure Density (20 C): ph-value at 20 C: Solubility in water: Liquid Colorless Odourless The Product is not self-igniting There is no substances in the kit could lead to the danger of explosion The product could solute in water easily 9.2 Other safety information No 10. STABILITY AND REACTIVITY 10.1 Reactivity The product is stable in accordance with the recommended storage conditions. 10.2 Chemical stability All the chemicals in the test kits are stable. 10.3 Possibility of hazardous reactions Almost impossible 10.4 Conditions to avoid Temperature out of 2-30 10.5 Incompatible materials No 10.6 Hazardous decomposition products No 11. TOXICOLOGICAL INFORMATION 11.1 Information on toxicological effects (Mixture) Acute toxicity: Quantitative date on the toxic effects of this product is not available. Irritation Irritating to skin and severely irritating or corrosive to eyes and, with greater exposures, can cause eye damage, including permanent impairment of vision or blindness. Corrosivity Corrosive to eyes; with greater exposures may cause eye injury. Harmful if swallowed. DAI Code # 44 38

Sensitisation Repeated dose toxicity Carcinogenicity: Mutagenicity: Toxicity for reproduction: Contains a small volume of a very dilute, sensitizing preservative (ProClin 300). Though the potential for an allergic response is greatly reduced by the dilution, sensitization threshold is unknown; thus, handle accordingly. Not yet investigate Not yet investigate. Not yet investigate No reproductive toxic effect known. 12. ECOLOGICAL INFORMATION 12.1 Toxicity 12.2 Persistence and degradability 12.3 Bioaccumulative potential 12.4 Mobility in soil 12.5 Results of PBT and vpvb assessment PBT/vPvB assessment not available as chemical safety assessment not required/not conducted 12.6 Other adverse effects 13. DISPOSAL CONSIDERATIONS 13.1 Waste treatment methods Product: European waste catalogue: Packaging: Chemical residues and remains should be routinely handled as special waste. This must be disposed of in compliance with anti-pollution and other laws of the country concerned. To ensure compliance we recommend that you contact the relevant (local) authorities and/or an approved waste-disposal company for information. 18 01 03 wastes whose collection and disposable is subject to special requirements in order to prevent infection. Disposal must be made in accordance with local waste management regulations. Contaminated packaging must be disposed of in the same manner as the product. Non-Contaminated packaging materials may be recycled. Contact your local service providers for further DAI Code # 44 39