Novel Rp-Hplc-Pda Method for the Simultaneous Estimation of Metoprolol Succinate and Chlorthalidone in Bulk and Pharmaceutical Dosage Forms

Similar documents
A Simple Rapid and Sensitive Method Development for Quantification of Quetiapine Fumarate in Bulk and Dosage Forms Using RP-HPLC

Simultaneous Estimation of Finasteride and Tamsulosin Hydrochloride in Combined Dosage Forms by RP-HPLC-PDA Method

10. Validated Normal Phase HPLC Method for the Determination. Fulvestrant is primarily used in the treatment of hormone receptor

Development and Validation of RP-HPLC-PDA Method for Simultaneous Estimation of Baclofen and Tizanidine in Bulk and Dosage Forms

International Journal of Pharma Research and Health Sciences. Available online at

Development and Validation of Isoniazid in Bulk and Pharmaceutical Dosage Forms by UFLC Method

Lakshmana Rao et.al Indian Journal of Research in Pharmacy and Biotechnology ISSN: (Print) ISSN: (Online)

Journal of Pharmaceutical and Bioanalytical Science

ISSN India; g,secunderabad. Abstractt. a flow rate. of 1ml/min. di hydrogen. which acts. and chronic. including minimize (5) Figure

Development and validation of stability indicating RP-HPLC method for the estimation of Daclatasvir in bulk and formulation

INTERNATIONAL RESEARCH JOURNAL OF PHARMACY

RP-HPLC Method for the Simultaneous Estimation of Lamivudine and Abacavir Sulphate in Tablet Dosage Form

DEVELOPMENT AND VALIDATION OF ANALYTICAL METHOD FOR ASSAY DETERMINATION OF ISOSULFAN BLUE BY LIQUID CHROMATOGRAPHY

Validation of Analytical Methods used for the Characterization, Physicochemical and Functional Analysis and of Biopharmaceuticals.

Usharani Gundala* 1, Chandrashekar Bonagiri 2, Devanna Nayakanti 3

P. Wadhwani College of Pharmacy, Yavatmal , India. *Corres.author: Cell No

CHAPTER-3. Zolmitriptan

International Journal of Research and Reviews in Pharmacy and Applied science.

Intercontinental journal of pharmaceutical Investigations and Research

Asian Journal of Research in Chemistry and Pharmaceutical Sciences Journal home page:

Jigar Mehta, Yauvan Pancholi, Vipul Patel, Nayan Kshatri, Niranjan Vyas*

Journal of Pharmaceutical and Biomedical Analysis Letters. Analysis Letters

IAJPS 2017, 4 (07), P. Hari Sravanth Reddy et al ISSN

Saudi Journal of Medical and Pharmaceutical Sciences

RESEARCH ARTICLE STABILITY INDICATING ANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF AVANAFIL IN PHARMACEUTICAL DOSAGE FORM

Development and validation of RP-HPLC method for simultaneous estimation of aspirin and omeprazole in dosage

Available Online through (or) IJPBS Volume 2 Issue 3 JULY-SEPT Research Article Pharmaceutical Sciences

Research Article. Development and validation of RP-HPLC method for the estimation of ropinirole hydrochloride in tablet dosage forms

Analytical Method Development and Validation for the Estimation of Abiraterone and its Impurity in Pharmaceutical Formulation By RP-HPLC

Validated Stability-indicating assay method for determination of Ilaprazole in bulk drug and tablets by high performance liquid chromatography

DIDANOSINE ORAL POWDER Final text for addition to The International Pharmacopoeia

International Journal of ChemTech Research CODEN (USA): IJCRGG, ISSN: , ISSN(Online): Vol.10 No.6, pp , 2017

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

Short Communication Stability Indicating Assay Method Development and Validation of Tolteridone Tartrate in Bulk Drug and Capsules

International Journal of Applied Pharmaceutical Sciences and Research

CHAPTER III STABILITY INDICATING ASSAY AND IMPURITIES METHODS FOR FIXED DOSE COMBINATION PRODUCT OF OMEPRAZOLE AND DOMPERIDONE

RP-HPLC METHOD FOR QUANTITATIVE ESTIMATION OF GLATIRAMER ACETATE FOR INJECTION IN PHARMACEUTICAL DOSAGE FORMS

Quantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 1200 Series RRLC and 6410B Triple Quadrupole LC/MS

Validated Stability Indicating RP-hplc Method for the Assay of Dienogest in Bulk and Tablet Dosage Form

Research Article PATEL PARESH U., PATEL BHAGIRATH M. *

International Journal of Institutional Pharmacy and Life Sciences 6(5): September-October 2016

NEW VALIDATED RP - HPLC METHOD FOR THE ESTIMATION OF DIAZEPAM IN DOSAGE FORMS

Validation of a Dual Wavelength Size Exclusion HPLC Method with Improved Sensitivity to Detect Aggregates of a Monoclonal Antibody Biotherapeutic

Quantitative determination of residual 2-(2-chloroethoxy) ethanol (CEE) in quetiapine fumarate by gas chromatogaraphy

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

CHAPTER 7 DETERMINATION OF RELATED SUBSTANCES OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

International Journal of Research in Pharmacy and Life Sciences. International Journal of Research in Pharmacy and Life Sciences

Stability-Indicating RP-HPLC Method for the Simultaneous Determination of Escitalopram Oxalate and Clonazepam

Impurity Control in the European Pharmacopoeia

Application Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau

THESIS SUBMITTED TO THE ANDHRA UNIVERSITY IN PARTIAL FULFILMENT FOR THE AWARD OF THE DEGREE OF DOCTOR OF PHILOSOPHY IN PHARMACEUTICAL SCIENCES

Research Article Validation of a Statistically Optimized Stability Indicating Method for the Estimation of Febuxostat in a Solid Dosage Form

Journal of Chemical and Pharmaceutical Research, 2017, 9(7): Research Article

Received: 10 May 2017 Revised and Accepted: 02 Nov 2017

Research Paper Development of Stability Indicating Reverse Phase HPLC Method for Aripiprazole from Solid Dosage form

e55 Page55 RESEARCH ARTICLE

Evaluation by Competent Authorities

Anantapuramu , Andhra Pradesh, India. Anantapur , Andhra Pradesh, India.

A validated stability indicating HPTLC method for determination of nitazoxanide

International Journal of Pharma Research & Review, Feb 2014; 3(2):11-16 ISSN:

ORIENTAL JOURNAL OF CHEMISTRY. An International Open Free Access, Peer Reviewed Research Journal.

VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY *)

Validation of Analytical Method of Irbesartan Plasma in Vitro by High Performance Liquid Chromatography-Fluorescence

Development of Quality Control Method for Dissolution Analysis of Tapentadol and paracetamolin tablet

METHOD FOR SIMULTANEOUS DETERMINATION OF FOLPET AND CYMOXANIL ACTIVE INGREDIENTS (COMBINATION PRODUCTS) IN AQUEOUS MEDIA

A NEW TECHNICAL METHOD FOR GLECAPREVIR AND PIBRENTASVIR IN COMBINED DOSAGE FORMS USING NON POLAR HPLC

TEMPLATE FOR AN EXAMPLE METHODS VALIDATION STANDARD OPERATING PROCEDURE (SOP)

STABILITY STUDIES OF RIBAVIRIN SYRUP

Stability Indicating RP-HPLC Method For The Determination Of Tapentadol In Bulk And In Pharmaceutical Dosage Form

VICH Topic GL2 (Validation: Methodology) GUIDELINE ON VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY

ISSN: X CODEN: IJPTFI Available Online through Research Article

DACLATASVIR TABLETS (DACLATASVIRI COMPRESSI) Proposal for The International Pharmacopoeia. (May 2018)

Development & Validation of RP-HPLC Method for Estimation of Dabigatran Etexilate Mesylate from Capsule Dosage Form

RP-HPLC Method Development and Validation for the Simultaneous Determination of Clindamycin and Miconazole in Pharmaceutical Dosage Forms

A green HPLC technique with a 100% water mobile phase for detecting imidacloprid and its metabolite 6-chloronicotinic acid

Development and Validation of HPTLC Method for Estimation of Tapentadol Hydrochloride

Experiment 11. DNA Composition by HPLC 1,2

RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF IPRATROPIUM BROMIDE AND LEVOSALBUTAMOL IN PHARMACEUTICAL METERED DOSE INHALERS

IJSER. (2E)-2-cyano-3-(3,4-dihydroxy-5-nitrophenyl)-N,N-diethylprop-2-enamide [Entacapone] 7

INTERNATIONAL PHARMACOPOEIA MONOGRAPH ON ARTEMETHER AND LUMEFANTRINE CAPSULES REVISED DRAFT FOR DISCUSSION

*Department of Pharmaceutical Chemistry and Drug Control, Faculty of Pharmacy, Damascus University, Mazzeh Street, Damascus, Syrian Arab Republic.

GUIDANCE NOTES ON ANALYTICAL METHOD VALIDATION

High Performance Thin Layer Chromatographic Determination of the Related Substances in Alprazolam Drug

DEVELOPMENT AND VALIDATION OF A STABILITY- INDICATING RP-HPLC METHOD FOR THE ESTIMATION OF ERLOTINIB IMPURITIES BY QbD APPROACH

SIMPLE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR DETERMINATION OF NORFLOXACIN IN PLASMA AND APPLICATION IN BIOEQUIVALENCE STUDY

Research Article. Optimization and validation of rapid and simple method for determination of Isoniazid and Pyrazinamide in plasma by HPLC-UV

QbD approach for analytical method development of anti-pschotic drug

Journal of Chemical and Pharmaceutical Research, 2012, 4(1): Research Article

Development of Difference Spectroscopic Method for the Estimation of Tapentadol Hydrochloride in Bulk and in Formulation

Chromatography 2015, 36, Technical Note

EAG.COM MATERIALS SCIENCES APPLICATION NOTE. By J. Tompkins 1, T. Spurgeon 1, R. Tobias 1, J. Anders 1, E. Butler-Roberts 2, and M.

DETERMINATION OF MYCOTOXINE DEOXYNIVALENOL IN WHEAT FLOUR AND WHEAT BRAN

Forced degradation studies and validated stability indicating HPTLC method for determination of miconazole nitrate in soft lozenges

CHAPTER 2 A New stability Indicating RP-HPLC method for related substances in Zolmitriptan

9/2/2014. USP Monograph Modernization. Todays topics. USP basic. Todays topics. - USP basic. - USP publications. - USP monograph modernization

Genotoxicity is the property of a compound

THIOPHANATE-METHYL in air 5606

Revision of 30 April 2013 draft, 4 November 2013

HPLC Studies on Degradation Behavior of Brivaracetam and Development of Validated Stability Indicating HPLC Assay Method

Transcription:

Research Article Novel Rp-Hplc-Pda Method for the Simultaneous Estimation of Metoprolol Succinate and Chlorthalidone in Bulk and Pharmaceutical Dosage Forms A. Naga Jyothi 1, Syed. Sadath Ali 2, Buchi. N. Nalluri 1, Aziz Unnisa 1,3 * 1 Department of Pharmaceutical Analysis, KVSR Siddhartha College of Pharmaceutical Sciences, Vijayawada, AP, India 2 Azad institute of Pharmacy and research, Lucknow, India 3 Research scholar, Sunrise University, Alwar, Rajasthan, India Abstract The main objective of the study was to develop and validate a simple, precise, economical LC-MS compatible analytical method for the simultaneous estimation of Metoprolol succinate (MET) and Chlorthalidone (CT) by RP-HPLC- PDA. The method was carried out on Inertsil ODS column using mixture of 10mM ammonium acetate: acetonitrile in the ratio of 70:30%v/v as mobile phase. The flow rate was 1mL/min with PDA detection at 220nm. The retention times of MET and CT were 5.6min and 7.5min respectively. MET and CT showed a good linearity in the concentration range of 5-25 µg/ml and 2-6 µg/ml with a correlation coefficients (R) of 0.996 and 0.995 respectively. The percentage recoveries were 99.17 and 99.75 for MET and CT respectively. The method developed was validated in accordance with ICH guidelines. All validation parameters were in compliance with the acceptance criteria. The method was successfully used for the routine analysis of MET and CT simultaneously in bulk and in combined formulations. Keywords: PDA Detection, Metoprolol succinate, Chlorthalidone, RP-HPLC, Validation *Correspondence Aziz Unnisa, Email: khushiazeez@yahoo.co.in Introduction Metoprolol succinate (MET), chemically is (±) 1(isopropylamino)-3-[p-(2-methoxyethyl) phenoxy]-2- propanolsuccinate (2:1) (salt) used in the treatment of hypertension [1], Chlorthalidone (CT) [2], a monosulfamyl diuretic chemically is 2-chloro-5-(1-hydroxy-3-oxo-1isoindolinyl) benzene sulfonamide. The combination of MET and CT as tablet dosage form was recently approved for the treatment of patients with mild to moderate essential hypertension and cardio vascular disorders [3]. Various analytical methods have been reported in the literature for the analysis of MET and CT individually or in combination with other drugs like Amlodipine, Aspirin, Olmesartan, Clonidine, Azilsartan medoximil, Telmisartan, Hydrochlorothiazide by LC-MS [4-5], stability indicating HPLC [6-12], HPTLC [13] and spectrophotometry [14-16]. However, no HPLC methods were reported so far for the simultaneous estimation of MET and CT in bulk and in tablets. Hence, the aim of present investigation was to develop a validated RP-HPLC-PDA method for the simultaneous estimation of MET and CT in pure form and tablet dosage form which is LC-MS compatible and economical. Chem Sci Rev Lett 2014, 3(12), 941-950 Article CS30204509 941

Material and Methods Chemicals & reagents MET and CT samples were obtained from Dr. Reddy s Laboratories Ltd, India. Ammonium acetate, water and methanol were purchased from E. Merck, India. All the reagents and solvents were of HPLC grade. VINICOR-D (manufactured by IPCA laboratories Ltd, Mumbai) tablets containing MET 23.75 mg (equivalent to Metoprolol tartrate 25 mg) and CT 6.25 mg were procured from the local market. Equipment A Shimadzu Prominence HPLC system provided with DGU-20A3 degasser, LC-20AD binary pumps, SIL-20AHT auto sampler, SPD-M20A PDA detector and Inertsil ODS 3 aqueous column (250 x 4.6 mm, 5 µ) was used. Data acquisition was carried out using LC solutions software. Chromatographic Conditions Mobile phase consisting of 10mM Ammonium acetate: acetonitrile (70:30 % v/v) was filtered through nylon disc filter of 0.45 µm (Millipore), sonicated for 3 min and used in isocratic mode at a flow rate of 1 ml/min and the injection volume is 10 µl. PDA detection was performed at 220 nm and the separation was achieved at ambient temperature. Preparation of standard solutions Stock solutions were prepared individually by dissolving 9.5 mg of Metaprolol succinate ( equivalent to 10 mg of Metaprolol tartrate) and 10 mg of CT in 10 ml volumetric flasks containing 5 ml of methanol and the volume was made up to mark with methanol. Aliquots of the individual stock solutions were further diluted with ammonium acetate to get the required standard concentrations in the range of 5-25 µg/ml and 2-6 µg/ml for MET and CT respectively. Validation of the HPLC method The method developed was validated in accordance with ICH guidelines. Linearity A linear relationship was evaluated across the range of the analytical procedure with a minimum of five concentrations. A series of standard dilutions of MET and CT were prepared over a concentration range of 5-25 μg/ml (5, 10, 15, 20, 25 μg/ml) and 2-6 μg/ml (2, 3, 4, 5, 6 μg/ml) respectively from stock solution and injected in triplicate. Linearity was estimated by a plot of peak areas as a function of analyte concentration and the test results were evaluated by calculating appropriate statistical parameters such as slope, intercept, correlation coefficients (R) and regression (R 2 ) Precision Precision is the measure of concordance between repeatedly obtained experimental values. Repeatability was assessed by using a minimum of six determinations at 100 % of the test concentration. This study was carried out by injecting six replicates of the standard and sample at a concentration of 15 μg/ml and 4 µg/ml of MET and CT respectively. The standard deviation and the RSD were computed for precision. Chem Sci Rev Lett 2014, 3(12), 941-950 Article CS30204509 942

Specificity The specificity of the method was determined by comparing the chromatograms obtained from the drug substance with that obtained from the diluent, placebo and sample solution. The retention times of drug substances and the drug products were observed. Absence of interference of excipients in the tablet proves the specificity of the proposed method. Accuracy Accuracy is the measure of closeness the experimental value to it s the true value. It should be established across the specified range of the analytical procedure. The accuracy of the proposed method was evaluated by performing recovery studies were performed by the standard addition method. The % recovery and the % RSD were calculated at each level of addition. Limit of Detection (LOD) and Limit of Quantification (LOQ) LOD and LOQ were calculated based on calibration curves. They were expressed as LOD = (3.3 σ)/m; LOQ= (10.0 σ)/m (Where, is the standard deviation of the y-intercepts of the three regression lines and m is mean of the slopes of the three calibration curves). Robustness Robustness is a measure of the method's capability to remain unaltered by small, but calculated variations. The method parameters like no. of theoretical plates, capacity factor, tailing factor and % assay were noted. It can be partly assured by good system suitability specifications. To study the effect of flow rate, ± 20 % change was made in flow rate. The effect of wavelength was studied by changing wavelength by ±1nm and effect of mobile phase by ± 2 %. The data was given in Table 2. System suitability System suitability was carried out by injecting a standard concentration at different injection volumes in the range of 10-50 μl. The test parameters were noted and % RSD was calculated. Assay Twenty tablets were weighed and finely powdered, the powder was accurately weighed which contains 10 mg of MET and 2.63 mg of CT and transferred into a 10 ml volumetric flask containing methanol and vortexed for 5 min and volume was adjusted up to the mark with methanol. This solution was centrifuged and then filtered using disposable syringe filter (13 mm, 0.4 µm). An aliquot of filtrate was diluted with ammonium acetate and analyzed in triplicate. The amount of drug present in the each tablet was quantified by comparing the area of standard MET and CT with that of the sample. Results and Discussion From literature review it is clearly evident that there were no HPLC methods so far reported on the simultaneous estimation of MET and CT in combined dosage form. Hence, the present investigation was aimed to develop a simple, precise, economical RP-HPLC-PDA method for the simultaneous estimation of MET and CT in bulk and pharmaceutical dosage forms. Chem Sci Rev Lett 2014, 3(12), 941-950 Article CS30204509 943

Method Development In this investigation efforts were made to develop a validated RP-HPLPDA method for the simultaneous analysis of MET and CT in bulk and pharmaceutical dosage forms. Initial trail was carried out with Phenomenex C 18 column (250 x 4.6 mm, 5 μ) using a mobile phase of water and methanol (50:50 % v/v) at a flow rate of 1 ml/min with the detector set at 220 nm. Under these conditions MET was eluted at 5.2 min and CT was not eluted within 15 min run mau 220nm,4nm (1.00) 25.0 7.590 22.5 20.0 17.5 A 15.0 12.5 5.567 10.0 7.5 5.0 2.5 0.0-2.5 0.200 Purity Curve Zero Line Peak mau 25.0 0.45 Purity Curve Zero Line Peak mau 32.5 0.175 22.5 0.40 30.0 20.0 0.35 27.5 0.150 25.0 0.125 B 17.5 15.0 0.30 0.25 22.5 20.0 0.100 12.5 0.20 17.5 15.0 0.075 10.0 0.15 12.5 0.050 7.5 0.10 10.0 0.025 5.0 0.05 7.5 5.0 0.000 2.5 0.00 2.5 5.5 5.6 5.7 5.8 5.9 6.0 6.1 6.2 min 0.0 7.20 7.25 7.30 7.35 7.40 7.45 7.50 7.55 7.60 7.65 7.70 7.75 min 0.0 mau 32.5 5.68/ 1.00 30.0 32.5 mau 7.50/ 1.00 27.5 30.0 25.0 22.5 20.0 223 27.5 25.0 22.5 20.0 C 17.5 17.5 15.0 15.0 12.5 12.5 10.0 10.0 7.5 7.5 5.0 275 5.0 2.5 0.0 361 2.5 0.0 276-2.5-2.5 200.0 225.0 250.0 275.0 300.0 325.0 350.0 375.0 nm 200.0 225.0 250.0 275.0 300.0 325.0 350.0 375.0 nm Figure 1 A Standard chromatogram of MET and CT mixture; B - Peak purity index of MET and CT; C - UV spectrum Chem Sci Rev Lett 2014, 3(12), 941-950 Article CS30204509 944

time. In the other trail 0.05 % v/v orthophosphoric acid (ph 2.3) was used as aqueous phase and methanol as organic modifier (80:20 % v/v) at a flow rate of 1mL/min with Phenomenex C 18 column (250 x 4.6 mm, 5 μ) and the peak retentions were not changed with this trial. In the next trail, 10mM ammonium acetate (ph 4.5) and acetonitrile (75:25 % v/v) was used using Inertsil ODS-3 column and the peaks were eluted at 5.2 min and 11min respectively for MET and CT however, peak tailing was observed with MET. To optimize the mobile phase composition the trails were carried out by using mixture of 10 mm ammonium acetate: acetonitrile (70:30 % v/v) as mobile phase and ammonium acetate as diluent at a flow rate of 1 ml/min. Under these conditions MET and CT were eluted at 5.6 min, 7.5 min respectively within 10 min of run time and no interference peaks were found. The validation of the method was performed as per ICH guidelines. The peak purity index of greater than 0.9998 indicates peak purity of the drug sample used in the analysis and shown in Figure 1 along with UV spectra. Method validation Linearity The range of reliable quantification was set at the concentrations of 5-25 μg/ml and 2-6 µg/ml of MET and CT respectively. This range was selected based on 80-120 % of the standard concentration used for accuracy and were analyzed in triplicate. Concentrations and Peak areas were subjected to least square regression analysis to calculate regression equation. The correlation coefficient (R) was found to be 0.996 and 0.995 indicating a linear response over the range used. The calibration data was given in Table 1. Table 1 Linearity, Accuracy, Precision, Assay and stability data for MET and CT Validation data of MET Validation data of CT Linearity (n=3) Range 5-25 µg/ml 2-6 µg/ml Regression equation y =15051x 16095 y =36401x 11173 Correlation coefficient R = 0.998 R = 0.998 Regression coefficient R 2 = 0.996 R 2 = 0.995 Accuracy (n=3) % Level of Addition 80 100 120 Precision (n=6) Mean Percent Recovery(%RSD) 99.83 (1.80) 100.3 (1.64) 99.50 (1.57) 99.23 (1.37) 100.1 (1.44) 98.86 (0.67) System Precision Average peak area (%RSD) 163591.3 (0.47%) Method Precision 129494.4 (0.10%) Percent Assay (% RSD) (n=3) 99.86 (0.578) 123736.4 (0.12%) 154041.9 (0.58%) 100.8 (0.717) Chem Sci Rev Lett 2014, 3(12), 941-950 Article CS30204509 945

Precision Precision studies were carried out in terms of repeatability. System precision: Repeatability of standard application was carried out using six replicates of the mixed standard concentration (15 μg/ml of MET and 4 μg/ml of CT). The % RSD of the peak area was found to be less than 1 indicating an acceptable level of precision for the analytical system. The data was given in Table 1 and the overlay of chromatograms shown in Figure 2A. Method precision: Repeatability of sample measurement was carried out in six replicates of the same sample preparations from same homogenous blend of marketed formulation(vinicor-d tablets). The % RSD of the peak area was found to be less than 1.The data was given in Table 1 and the overlay of chromatograms shown in Figure 2B 17500 uv 15000 12500 uv 17500 15000 12500 10000 A 7500 10000 5000 2500 7500 0 5000 2500 0 25000 uv 22500 20000 17500 15000 12500 10000 7500 5000 2500 0-2500 -5000 uv 27500 25000 22500 20000 17500 15000 12500 10000 7500 5000 2500 0-2500 B Figure 2 A-System precision data; B- Method precision data for MET and CT Chem Sci Rev Lett 2014, 3(12), 941-950 Article CS30204509 946

Accuracy Accuracy of the proposed method was ascertained by performing recovery studies by standard addition method by spiking the known quantities of standard at 80 %, 100 %, 120 % to the drug product solution of 15 μg/ml and 4 ug/ml and these solutions were analyzed in triplicate in each level of addition. The % RSD and the % Recovery were in compliance with specified limits. It is clear from the results of accuracy study given in Table 1, that the proposed method enables accurate quantitative estimation of MET and CT. Assay Assay of VINICOR-D tablets was performed by the proposed method and the % assay of the formulation was calculated as an average of 3 determinations, which was about 99.8 0.58 and 100.8 0.73 for MET and CT respectively. These results indicate that the present HPLC method can be successfully used for the simultaneous analysis of MET and CT in bulk and pharmaceutical dosage forms, the results of assay given in Table 1. Specificity The specificity of the method was established by injecting the solutions of diluent, placebo, standard, sample individually to examine any interference. The 3D plots of diluent, placebo, standard and sample are shown in Figure 3 and overlay of chromatograms as shown in Figure 4 and From these figures it can be inferred that there were no coeluting peaks at the retention time of MET and CT, this shows that peak of analyte was pure and the excipients in the formulation did not interfere with the analysis and the peak purity indices for sample and standard was found to be more than 0.999 and this depicts specificity of the method. A B C D Figure 3 3D plots of the chromatograms for diluent (A); placebo (B); standard(c) and drug product (D) Chem Sci Rev Lett 2014, 3(12), 941-950 Article CS30204509 947

45000 uv 40000 35000 30000 25000 20000 15000 10000 5000 0 D C B A -5000 Figure 4 Specificity data for the chromatograms of diluent (A); placebo (B); standard (C) and drug product (D) Limit of Detection (LOD) and Limit of Quantification (LOQ) LOD and LOQ were determined based on statistical calculation from the calibration curves. The limit of detection for MET and CT was found to be 0.339 μg/ml and 1.029 μg/ml respectively, the analyte peak could be distinguished without any base line disturbances at this concentration. The limit of quantification for MET and CT was found to be 0.217 g/ml and 0.659 μg/ml respectively. Robustness As part of the robustness, a deliberate change in the flow rate and wavelength was made to evaluate the impact on the method. Retention times were slightly changed with flow rate but no change in the retention time was observed. Percent assay values were also estimated under these changed conditions and the results were given in Table 2. These results indicated that the method is robust in terms of deliberate changes with the mobile phase ratio, flow rate and wavelength. Table 2 Robustness data of MET and CT Chromatographic parameters Theoretical plate Retention time(min) Tailing factor (Tf) number MET CT MET CT MET CT Wavelength(nm) 218 220 222 % B of mobile phase 32 30 28 Flow rate (ml/min) 0.9 1.0 1.1 5.56 5.56 5.56 5.27 5.81 6.52 6.57 5.02 5.27 7.59 7.59 7.59 6.71 7.65 8.78 8.39 7.60 6.89 7473.43 7470.35 7468.19 7162.45 7457.55 7914.29 7890.63 7457.75 7095.22 12287.22 12285.70 12290.10 11950.76 12801.89 13902.21 13336.06 12256.74 11930.52 1.41 1.41 1.41 1.43 1.43 1.42 1.45 1.43 1.19 1.12 1.12 1.12 1.12 1.09 1.08 1.09 1.08 1.10 Chem Sci Rev Lett 2014, 3(12), 941-950 Article CS30204509 948

System suitability System suitability testing is an integral part of the analytical procedure. The studies were carried out by injecting five times a 15 g/ml and 4 g/ml standard concentration of MET and CT at different injection volumes ranging from 10-50 L. The % RSD values for system suitability test parameters like tailing factor, retention time and theoretical plate number were all less than 2% and indicating the given conditions were suitable for the simultaneous analysis of MET and CT in tablets. Stability of the stock solution The stability of the stock and standard solutions were determined by analyzing the samples under refrigeration (8 ± 1 C) at different time intervals up to 48 hrs. The % variation in assay values at different time intervals were found to be less than 2 % of the initial zero time interval solution, demonstrating that the solutions were stable for a period of 48 hrs when stored at 8 C. Conclusion A new, RP- HPLC method has been developed for the simultaneous analysis of MET and CT in tablet dosage forms. The method was fully validated as per International Conference on Harmonisation (ICH) Guidelines and found to be applicable for routine quality control analysis for the simultaneous estimation of MET and CT in tablets using isocratic binary mode of elution. The results of linearity, precision, accuracy and specificity were all within limits and proved the reliability of method. The method provides selective quantification of MET and CT without interference from diluents. Therefore, this method can be employed in quality control for the simultaneous estimation of MET and CT in bulk and in tablets. Acknowledgements The authors are thankful to Dr. Reddy s Laboratories Ltd, India for providing gift samples of drugs and also to the Siddhartha Academy of General and Technical Education, A.P., for providing necessary facilities to carry out the research work. References [1] Martindale-The Complete Drug Reference, 32 nd edn, Pharmaceutical press, The Royal Pharmaceutical Society, London, 2005, p 931.2-932.1. [2] The United State Pharmacopoeia 27th Revision, National Formulary 22, US Pharmacopoeia Convention, Rockville, MD, 2004, p 1230-1231. [3] CIMS India,119 update, Jan-April 2013, p 90-91. [4] B.P. Jensen, C.F. Sharp, J. Sharon Gardiner and J. Evan begg, Journal of chromatography B., 2008, 86, 48-54. [5] P. Sharma, P. Daxesh Patel, S. Pranav Shrivastav, Journal of pharmaceutical analysis., 2013, 3, 1-17. [6] F. Belal, A.M. El-Brashy, N. El-Enany, M. M. Tolba, Acta Chromatographica., 2012, 24, 185-206. [7] M. Aqil, A. Ali, A. Ahad, Y. Sultana, A. K. Najmi, N. Saha, Acta Chromatographica., 2007, 19,130-140. [8] D. Mitesh Phale, D. Purnima Hamrapurkar, Asian Journal of Research Chemistry., 2009, 2, 119-122. [9] M. Mehul Patel and D. Disha Patel, Journal of Chromatographic Separation Techniques., 2012, 3,151. [10] R.A. Mhaske, S. Sahasrabudhe, A.A. Mhaske, International Journal of Pharmaceutical Sciences and Research., 2012, 3, 793-801. [11] S. Sahoo, SK Mishra and PK Panda, International Journal for Pharmaceutical Research Scholars., 2012, 1, 1-4. [12] V. Rajamanickam, B. Stephen Rathinaraj, N. Thangavelpandian, Der Pharmacia Lettre., 2010, 2, 40-46. [13] M. Youssef, M. Rasha Maher, El-Kimary, I. Eman, Journal of the Association of Official Analytical Chemists International., 2013, 96, 313-323. Chem Sci Rev Lett 2014, 3(12), 941-950 Article CS30204509 949

[14] S. Sohan Chitlange, D. Ramesh Bhusal and B. Monesh Nikumbh, International Journal of Pharmacy., 2012, 2, 591-597. [15] N. Moreshwar Kulkarni1, V. Rajeshwar Kshirsagar and M. Dinesh, International Journal of Chem Tech Research., 2009, 1, 1273-1277. [16] El-Gindy, S. Emara, A. Mostafa, Farmaco., 2005, 60, 269-278. 2014, by the Authors. The articles published from this journal are distributed to the public under Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0/). Therefore, upon proper citation of the original work, all the articles can be used without any restriction or can be distributed in any medium in any form. Publication History Received 30 th Sep 2014 Revised 10 th Oct 2014 Accepted 18 th Oct 2014 Online 30 th Oct 2014 Chem Sci Rev Lett 2014, 3(12), 941-950 Article CS30204509 950