Municipal Wastewater. Introduction: Sample Matrix: Wastewater; various locations along the sewage treatment process.

Similar documents
Real Time BOD Estimations by Automated PeCOD COD Analysis on the New PC-BOD/COD Duo

PeCOD: The New Way to Measure True COD for Laboratory or On-Line Monitoring

MANTECH. PeCOD Analyzer. Faster, Greener, Safer COD Analysis. Load. Start. Done.

Rapid Source and Treated Water Quality Testing using Chemical Oxygen Demand. Justin Dickerman, MANTECH

Page 1. WEAO 2017 Technical Conference, Ottawa, Ontario

Oxygen Demand, Chemical

PeCOD COD Monitoring. FAST, SAFE & GREEN Results

Oxygen Demand, Chemical

Phosphorus, Reactive (Orthophosphate)

OBSERVATIONS OF AN OPERATOR IN THE LAB IMPROVING LABORATORY RESULTS. Shane Jordan-Hill. Merck Millipore

EHS SMART-Treat Onsite Moving Media Treatment System

CEE 311 Environmental Engineering I Fall 2015 Dr. Jagadish Torlapati BIOCHEMICAL OXYGEN DEMAND (BOD)

Hach Method Luminescence Measurement of Dissolved Oxygen (LDO ) in Water and Wastewater

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement, 0 to 40 mg/l COD

Application Notes for COD Analysis DETERMINATION OF CHEMICAL OXYGEN DEMAND (COD) IN WATER AND WASTE WATER.

BIOTECTOR TOC Analysers

USEPA 1,2 Bicinchoninate Method 3 Method 8506 (CuVer 1) and Method 8026 (CuVer 2) 0.04 to 5.00 mg/l Cu Powder Pillows or AccuVac Ampuls

PHOSPHORUS, REACTIVE (0.00 to 5.00 mg/l PO 4

ACRP. Fact Sheets. On-Site Monitoring Methods AIRPORT COOPERATIVE RESEARCH PROGRAM. Sponsored by the Federal Aviation Administration

Auburn University Department of Civil Engineering Introduction to Environmental Engineering CIVL Laboratory #6 Chemical Oxygen Demand (COD)

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement

Sulfate. USEPA 1 SulfaVer 4 Method 2 Method to 70 mg/l SO 4. Powder Pillows. Test preparation. Before starting.

Process Control Testing Copyright February 1, All rights reserved.

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

BRISTOL- MYERS SQUIBB WORKS HARD TO BE A GOOD NEIGHBOR

Complete Water Analysis Solutions for Power, Heat & Steam Generation

Oxygen Demand, Chemical

ISO INTERNATIONAL STANDARD. Water quality Determination of the chemical oxygen demand index (ST-COD) Small-scale sealed-tube method

When this process occurs in water, the oxygen consumed is dissolved oxygen.

1-(2-Pyridylazo)-2-Naphthol PAN Method 1 Method to mg/l Mn (LR) Powder Pillows

USEPA 1 Periodate Oxidation Method 2 Method to 20.0 mg/l Mn (HR) Powder Pillows

Oxygen Demand, Chemical

Kjeldahl analysis with FOSS Kjeltec systems more clever than ever. Dedicated Analytical Solutions

SOP_Chem_001 Chemical Analysis_ Chemical Oxygen Demand. Standard Operation Procedure Chemical Oxygen Demand Closed Reflux, Titrimetric Method

Color, True and Apparent, LR

SKALAR. your partner in chemistry automation. SP series Robotic Analyzers

Contents General Information Abbreviations and Acronyms Chapter 1 Wastewater Treatment and the Development of Activated Sludge

Cuvette Test LCK 555 BOD 5 /BOD [n]

AUTOMATED ONLINE WATER QUALITY MONITORING. From ZAPS Technologies Product Brochure

Uranium Testing and Site Calibration for Water Testing Detection Range: 2 60ppb

Cuvette Test LCK 555 BOD 5 /BOD [n]

TREATMENT OF DAIRY WASTE WATER BY MORINGA OLEIFERA AS NATURAL COAGULANT

Cuvette Test LCK 555 BOD 5 /BOD [n]

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

Dimethylphenol Method Method LR (0.23 to mg/l NO 3 N or 1.00 to mg/l NO 3 ) TNTplus 835

ICP Expert software. Technical Overview. Introduction

Simplicity. Accuracy. Durability. Lotix. Automated High Temperature Combustion TOC Analyzer

3. Add 0.4 ml of. 7. Use a TenSette

Nitrogen, Simplified TKN (s-tkn )

WWETCO FlexFilter and Bio-FlexFilter

Microfluidic platform for multiparameter water quality analysis

Phosphorus, Reactive (Orthophosphate)

UV300 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

Fully Automated EIA System. True open flexibility.

UV400 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

Chemical Oxygen Demand Flow Rate Effect on Total COD and the Particulate/Soluble COD Ratio

Practical guidance for switching between anion and cation analysis systems

Standard Operating Procedure for the Determination of Specific Conductance CCAL 11A.2

Cadmium Testing and On Site Calibration for Water Testing Detection Range: ppm

CX-1 ph Gradient Buffer

Complete. Compact. Compliant.

Phosphorus, Reactive (Orthophosphate)

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

A Computer Controlled Multi-Analysis Titration System

CASE STUDY: ROYAL AUSTRALIAN AIR FORCE BASE, AMBERLEY SEWAGE TREATMENT PLANT

Zinc Testing and On Site Calibration for Water Testing Detection Range: 1 15ppm

LANGE LABORATORY AUTOMATION >>GANIMEDE SERIAL DIGESTION. The serial analysis system for total P and N (TN b ) with integrated digestion.

STOPPING WATER POLLUTION AT ITS SOURCE

Automation in the operations lab: From cuvette test to GANIMEDE

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II AA Mercury Analyzer

COMPREHENSIVE WASTE REDUCTION AT VON DUPRIN, INC. Daniel Reinke, P.E. Capsule Environmental Engineering, Inc. St. Paul, Minnesota

Module 11 : Water Quality And Estimation Of Organic Content. Lecture 14 : Water Quality And Estimation Of Organic Content

Rat IgG ELISA Catalog #:

Boiler Water No.2 Test Kit Instruction Manual

Biodegradation Test of Chemical Substances

METHOD DETERMINATION OF TURBIDITY BY NEPHELOMETRY. Edited by James W. O'Dell Inorganic Chemistry Branch Chemistry Research Division

News. Power Generation 11. ph Control Reduces Acid Consumption in Neutralization Process up to 90 % Perspectives in Pure Water Analytics THORNTON

Utilisation Of Natural Coagulant For Reduction Of Turbidity From Waste water

INFORMATION PROCESS ANALYSIS ON-SITE ANALYSERS AMTAX SC + PHOSPHAX SC. Short paths optimal results On-site analysers for Ammonium and Phosphate

Method 8017 (0.7 to 80.0 µg/l) Powder Pillows. Scope and Application: For water and wastewater; digestion is required to determine total cadmium.

Date: July 8, Prepared by: Brian O Connor and Serge Genest, FPInnovations 570 St. Johns Blvd, Pointe-Claire, Quebec, Canada

XDS TM Multipurpose NIR-analyser for Laboratories

Water Chemistry and Plant Performance

SurTec 717 Alkaline Zinc/Nickel Electroplating Process (Electrolyte based on Sodium)

Optimizing Water Reclamation Systems by Automation using Continuous Water Quality Analysis

Simplicity. Accuracy. Durability. Lotix. Automated High Temperature Combustion TOC Analyzer

****** Competition ELISA Kit Instruction

1. Overview 2 2. Definitions 2 3. Laboratory Testing Criteria 2. A. Laboratory Qualifications 2. B. Analysis of TSS Samples 2. C.

Application Note AN1501

Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric)

/ Marley MARPAK Modular Biomedia /

CHEMICAL FREE PHOSPHOROUS ELIMINSTION P-UPTAKE PROCESS

Rat Free Thyroxine (FT4) ELISA Kit

BOD/CBOD, TSS ph OPERATOR BASICS. Presented by: Marcy Bolek - Alloway

Scope and application: For water and wastewater. Turbid samples are filtered during the analysis.

QAM-I-113 Operation and Calibration of the Dissolved Oxygen Meter

Module 11 : Water Quality And Estimation Of Organic Content. Lecture 13 : Water Quality And Estimation Of Organic Content

Copies: Mark Hildebrand (NCA) ARCADIS Project No.: April 10, Task A 3100

Defense Technical Information Center Compilation Part Notice

NovaWAVE. A new category of Automated Microwave Digestion

Transcription:

Municipal Wastewater Introduction: Chemical Oxygen Demand (COD) and Biochemical Oxygen Demand () are important diagnostic parameters for the determination of water quality in natural waterways and waste streams. The standard test requires five days to complete, and is therefore unable to provide continuous monitoring of organic load. COD is therefore often used for screening. The PeCOD method for COD analysis is a new technology that uses photoactive TiO 2 nanomaterials that directly measures the amount of oxidizable material in a sample. Unlike the standard dichromate method for COD analysis, this new method is fast (5-1 minutes per sample) and it eliminates the need for hazardous chemicals, which helps ensure the safety of laboratory staff, reduces disposal costs, and helps companies meet green initiatives. The PeCOD method for COD analysis is well suited to the waste water industry since the fast results obtained helps provide information important for process monitoring and control. Constant COD monitoring can protect wastewater treatment plants from high COD events by providing advance notice of any problem streams. It also provides the opportunity for plant optimization. Aeration and power consumption used in the process for COD removal can be fine-tuned based on the requirements of the plant, rather than constantly running at a level higher than necessary to allow for the possibility of high COD loads. Event monitoring will also improve the environmental performance of a plant and lower discharge costs. This document describes the application of the PeCOD COD Analyzer for the wastewater industry, focusing on the City of Cincinnati who is a current PeCOD enduser. This particular municipality has a population over two million people and therefore is a good representation of other wastewater treatment plants. Matrix: Wastewater; various locations along the sewage treatment process. Concentration Range: Variable; This enduser reports COD values ranging from 25mg/L. Apparatus: Note: Apparatus listed below is for a laboratory unit. Additional hardware can be added for a more automated COD solution. An online COD analyzer is also available for continuous monitoring of COD at specific process locations. 1. PeCOD Laboratory/Portable COD Analyzer (L1) 2. MANTECH software and interface for complete control of PeCOD L1. Optional add-ons for COD automation: 1. MANTECH AutoMax73 sampler 2. Patented dosing pump for automatic electrolyte addition 3. PC-Titrate TitraSip for automatic sample pipetting and ph-adjustment 4. Reagent addition pump for automatic sample dilution Load. Start. Done. info@mantech-inc.com Page 1 of 6

Additional Equipment: 1. System controller with Labterm installed 2. Sensors for PeCOD COD Analyzers, pack of 5. 3. Battery and carrying case for portable use. 4. PeCOD Single Range Starter Kit, BLUE Range (<25mg/L) 5. PeCOD Single Range Starter Kit, GREEN Range (<15mg/L) 6. PeCOD Single Range Starter Kit, YELLOW Range (<15mg/L) 7. PeCOD Single Range Starter Kit, RED Range (<15mg/L) Reagents: 1. Premium Electrolyte solution BLUE Range, 1L 2. Premium Electrolyte solution GREEN Range, 1L 3. Premium Electrolyte solution YELLOW Range, 1L 4. Premium Electrolyte solution RED Range, 1L 5. Calibrant Solution BLUE Range, 1L 6. Calibrant Solution GREEN Range, 1L 7. Calibrant Solution YELLOW Range, 1L 8. Calibrant Solution RED Range, 1L 9. Deionized water for rinsing, dilutions and blank preparation Procedure: Note: The procedure listed below refers to a stand alone PeCOD COD system. The MANTECH PC- Titrate automated COD system option eliminates many sample preparation steps and allows for multiple samples to be analyzed together in one batch without user intervention. Calibration: 1. Pipette the appropriate amount of calibrant and electrolyte into a tube according to the desired analysis range. Swirl to mix. 2. Place the port A line into solution and prime a few times. 3. Run two calibrations to properly hydrate and calibrate the sensor. Results will be displayed on the screen when the calibrations are complete. Preparation: 1. If samples contain large particles, they should be filtered with a 5µm filter to avoid clogging the PeCOD COD Analyzer. 2. If samples have been preserved with acid, they must be neutralized to a ph range of 4-1 with NaOH before analysis. 3. If necessary, samples can be diluted with DI water prior to analysis to allow for the measurement of extremely high COD samples, or to reduce the effects of interferences. Analysis: 1. Pipette the appropriate amount of sample and electrolyte into a tube according to the desired analysis range. Swirl to mix. 2. Place the port A line into solution and prime a few times. 3. Run the sample. Results will be displayed on the screen once oxidation is complete. Load. Start. Done. info@mantech-inc.com Page 2 of 6

Results and Discussion: MANTECH INC. The City of Cincinnati uses the PeCOD regularly as a screening tool. They also have two MANTECH automated systems which are used for reporting final numbers, but the ability to prescreen their samples on the PeCOD helps reduce the number of dilutions required. They have run a number of their samples through comparison studies alongside the dichromate COD test and have actually found that PeCOD COD tends to correlate better with than dichromate COD values. Below are charts demonstrating the correlation observed between, PeCOD COD and for influent, effluent, secondary combined and final samples analyzed by this municipality. COD/ value (mg/l) 9 8 7 6 5 4 3 2 1 PeCOD COD Figure 1: Plot of, PeCOD COD and for a US Municipal Treatment Plant influent sample. A similar pattern should be observed for each trend line, which is apparent for PeCOD COD and, while results are more variable. Load. Start. Done. info@mantech-inc.com Page 3 of 6

COD/ Value (mg/l) 12 1 8 6 4 2 PeCOD COD Figure 2: Plot of, PeCOD COD and for a US Municipal Treatment Plant effluent sample. PeCOD COD demonstrates a much stronger correlation to than Dichromate COD values and in fact are almost equal. 7 COD/ Value (mg/l) 6 5 4 3 2 1 PeCOD COD*.6 Figure 3: Plot of, and PeCOD COD with a factor of.6 applied to PeCOD values for a secondary combined sample from a US Municipal Treatment Plant. This factor was applied to COD values as it provides very close estimations of for most of the samples. As noted by the enduser, 2 small outliers may be observed in this data set because of extremely dark and turbid samples which may make representative sampling more difficult. Load. Start. Done. info@mantech-inc.com Page 4 of 6

COD/ Value (mg/l) 8 7 6 5 4 3 2 1 PeCOD COD Figure 4: Plot of, PeCOD COD and for a US Municipal Treatment Plant final sample. A good correlation is observed between all trends, with PeCOD COD and showing an excellent correlation. These graphs demonstrate the excellent correlation observed between PeCOD COD and. In all cases, the correlation observed is stronger than that between dichromate COD and. This means that the PeCOD will give the treatment plant accurate and valuable process control information, and in a fraction of the time required for either the dichromate COD or tests. It will also provide a more accurate estimate of, meaning that fewer dilutions will be required. As apparent from the curves, PeCOD COD tends to report a lower value than dichromate COD. This is because PeCOD COD reports soluble COD as opposed to total COD which is reported by the dichromate method. Raw wastewater samples may contain large amounts of solids which, when analyzed utilizing the dichromate method, are broken down during digestion and therefore end up contributing to the final COD. Since most of the solids are typically removed during the first stage of treatment, they actually have a low impact on the energy requirements of the secondary phase. This means that in the wastewater industry, soluble COD is actually a better indicator of the treatment process than total COD. It is also more representative of since digestion steps are not required for testing either. This is the reason behind the strong correlation between PeCOD COD and. Additionally, since the dichromate test is unable to differentiate between soluble and total COD, the PeCOD is actually providing another valuable result that municipalities have never had access to before. Conclusion While both and COD are core tests that are an integral part of all water quality management programs, waiting five days for results is unrealistic for providing process control information. While the dichromate COD test is an improvement in speed over the method, it still takes 2-3 hours to run and requires the use of hazardous chemicals. The cost of analysis is expensive and the requirement for hazardous waste disposals only adds to the expense. The PeCOD requires only a simple electrolyte solution and sugar-based calibrant to run, consumable requirements are low and inexpensive, and accurate and precise results are generated in only 5-1 minutes. The PeCOD is therefore ideal for the wastewater industry as it provides the benefit of more continuous organic Load. Start. Done. info@mantech-inc.com Page 5 of 6

monitoring, ensuring constant compliance with regulations. Additionally, its function as a screening tool greatly reduces the number of dilutions required for analysis. Hints and Suggestions 1. The PeCOD is also available as an online COD analyzer (P1 model) which is used for unattended monitoring. Results are communicated using a 4-2mA current loop that can interface to most control systems. The system is programmed to automatically calibrate and run samples at user defined intervals. It requires power, water and compressed air which is used to backflush the sampling probe (which has a 5um screen on the end to filter out solids) to keep it clear and unblocked. This is done automatically after every sample and ensures that the sample screen is kept clean and free of growths, which is especially important for extremely dirty samples like raw sewage. 2. The PeCOD AssayPlus is a fully automated chemical oxygen demand system, ideal for those with higher sample loads. This utilizes the laboratory unit along with a 73-position AutoMax autosampler and a dosing pump for the automatic addition of electrolyte. s are loaded into the autosampler by the user and the system automates all sample preparation and analysis steps. 3. Upgrades to the PeCOD AssayPlus include options for ph adjustment, auto-dilution of samples and multi-parameter analysis. The addition of a TitraSip module to the system means that preserved samples can be automatically adjusted to within the appropriate ph range, and high COD samples can be automatically diluted prior to analysis. Furthermore, if the initial COD result is reported beyond a predetermined value, the system is able to further dilute the sample and immediately re-analyse. In addition to COD automation, additional parameters such as ph, alkalinity, turbidity, etc. can be added to the system and analysed from the same sample tube if desired. 4. The PC-/COD Duo is a dual platform system combining the PeCOD AssayPlus with PC-. This allows for both the automated analysis of chemical oxygen demand using the new PeCOD technology, as well as biochemical oxygen demand analysis following 21 st Edition Standard Methods. COD is analyzed first in order to obtain the estimated values, which helps determine the appropriate dilution factor to use during analysis. Following a simple swap of autosampler racks and probes, analysis can then proceed. Rather than two separate systems, the PC-/COD Duo combines these methods into one efficient automated system providing a more effective utilization of laboratory equipment. Load. Start. Done. info@mantech-inc.com Page 6 of 6