ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Eddy current testing of welds by complex-plane analysis

Similar documents
INTERNATIONAL STANDARD

ISO 4987 INTERNATIONAL STANDARD. Steel castings Liquid penetrant inspection. Pièces moulées en acier Contrôle par ressuage. Second edition

ISO INTERNATIONAL STANDARD. Welding coordination Tasks and responsibilities. Coordination en soudage Tâches et responsabilités

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Ultrasonic testing Techniques, testing levels, and assessment

ISO 4986 INTERNATIONAL STANDARD. Steel castings Magnetic particle inspection. Pièces moulées en acier Contrôle par magnétoscopie

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Quality requirements for fusion welding of metallic materials Part 2: Comprehensive quality requirements

ISO Non-destructive testing of welds Ultrasonic testing Use of automated phased array technology

ISO 4986 INTERNATIONAL STANDARD. Steel castings Magnetic particle inspection. Pièces moulées en acier Contrôle par magnétoscopie

ISO INTERNATIONAL STANDARD. Hot-rolled stainless steel plates Tolerances on dimensions and shape

ISO INTERNATIONAL STANDARD. Equipment for crop protection Induction hoppers Part 2: General requirements and performance limits

ISO INTERNATIONAL STANDARD. Metallic materials Vickers hardness test Part 3: Calibration of reference blocks

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Non-destructive testing Qualification of personnel for limited applications of non-destructive testing

ISO INTERNATIONAL STANDARD. Quality requirements for fusion welding of metallic materials Part 4: Elementary quality requirements

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Resistance welding Spot welding of aluminium and aluminium alloys Weldability, welding and testing

ISO INTERNATIONAL STANDARD. Wood-based panels Determination of modulus of elasticity in bending and of bending strength

ISO 835 INTERNATIONAL STANDARD. Laboratory glassware Graduated pipettes. Verrerie de laboratoire Pipettes graduées. First edition

ISO INTERNATIONAL STANDARD. Fibre-reinforced plastics Determination of fatigue properties under cyclic loading conditions

ISO 5922 INTERNATIONAL STANDARD. Malleable cast iron. Fonte malléable. Second edition Reference number ISO 5922:2005(E)

ISO 5178 INTERNATIONAL STANDARD. Destructive tests on welds in metallic materials Longitudinal tensile test on weld metal in fusion welded joints

ISO 8872 INTERNATIONAL STANDARD. Aluminium caps for transfusion, infusion and injection bottles General requirements and test methods

ISO INTERNATIONAL STANDARD

ISO 1217 INTERNATIONAL STANDARD. Displacement compressors Acceptance tests. Compresseurs volumétriques Essais de réception. Fourth edition

ISO INTERNATIONAL STANDARD. Earth-moving machinery Anti-theft systems Classification and performance

ISO 3077 INTERNATIONAL STANDARD. Short-link chain for lifting purposes Grade T, (types T, DAT and DT), finetolerance

ISO INTERNATIONAL STANDARD. Quality management systems Guidelines for configuration management

ISO 8340 INTERNATIONAL STANDARD. Building construction Sealants Determination of tensile properties at maintained extension

ISO 2808 INTERNATIONAL STANDARD. Paints and varnishes Determination of film thickness. Peintures et vernis Détermination de l'épaisseur du feuil

ISO INTERNATIONAL STANDARD. Machine-tools safety Safety requirements for the design and construction of work holding chucks

ISO INTERNATIONAL STANDARD

ISO 4587 INTERNATIONAL STANDARD. Adhesives Determination of tensile lap-shear strength of rigid-to-rigid bonded assemblies

ISO INTERNATIONAL STANDARD. Road construction and maintenance equipment Asphalt mixing plants Terminology and commercial specifications

ISO INTERNATIONAL STANDARD. Compressed air Part 1: Contaminants and purity classes. Air comprimé Partie 1: Polluants et classes de pureté

ISO 648 INTERNATIONAL STANDARD. Laboratory glassware Single-volume pipettes. Verrerie de laboratoire Pipettes à un volume. Second edition

ISO INTERNATIONAL STANDARD. Paper and board Testing of cores Part 9: Determination of flat crush resistance

ISO INTERNATIONAL STANDARD. Road construction and maintenance equipment Asphalt mixing plants Terminology and commercial specifications

ISO INTERNATIONAL STANDARD. Cranes Design calculation for rail wheels and associated trolley track supporting structure Part 1: General

ISO INTERNATIONAL STANDARD. Cranes Stiffness Bridge and gantry cranes

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Plastics Decorative solid surfacing materials Part 1: Classification and specifications

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

ISO 8307 INTERNATIONAL STANDARD. Flexible cellular polymeric materials Determination of resilience by ball rebound

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Fatigue Design procedure for welded hollow-section joints Recommendations

Sýnishorn ISO 9004 INTERNATIONAL STANDARD. Managing for the sustained success of an organization A quality management approach

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Metallic materials Vickers hardness test Part 1: Test method

ISO INTERNATIONAL STANDARD. Random sampling and randomization procedures. Modes opératoires d'échantillonnage et de répartition aléatoires

ISO 8339 INTERNATIONAL STANDARD. Building construction Sealants Determination of tensile properties (Extension to break)

ISO INTERNATIONAL STANDARD. Water quality Measurement of gross alpha and gross beta activity in nonsaline water Thin source deposit method

ISO INTERNATIONAL STANDARD. Paper and board Determination of tensile properties Part 2: Constant rate of elongation method (20 mm/min)

INTERNATIONAL STANDARD

ISO 3369 INTERNATIONAL STANDARD. Impermeable sintered metal materials and hardmetals Determination of density

ISO INTERNATIONAL STANDARD. Metallic materials Sheet and strip Determination of plastic strain ratio

ISO INTERNATIONAL STANDARD

ISO 2177 INTERNATIONAL STANDARD. Metallic coatings Measurement of coating thickness Coulometric method by anodic dissolution

ISO INTERNATIONAL STANDARD. Packaging Flexible intermediate bulk containers (FIBCs) for non-dangerous goods

ISO INTERNATIONAL STANDARD. Metallic powders Determination of apparent density Part 1: Funnel method

ISO INTERNATIONAL STANDARD. Diesel engines NOx reduction agent AUS 32 Part 4: Refilling interface

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Industrial trucks Verification of stability Part 14: Rough-terrain variable-reach trucks

ISO INTERNATIONAL STANDARD

ISO 7183 INTERNATIONAL STANDARD. Compressed-air dryers Specifications and testing. Sécheurs à air comprimé Spécifications et essais

ISO INTERNATIONAL STANDARD. Road vehicles Electrical and electronic equipment for a supply voltage of 42 V Electrical loads

ISO INTERNATIONAL STANDARD. Plain bearings Quality control techniques and inspection of geometrical and material quality characteristics

ISO INTERNATIONAL STANDARD. Pallets for materials handling Quality of assembly of new wooden pallets

ISO INTERNATIONAL STANDARD. Textile machinery and accessories Profile reeds for air jet weaving machines Dimensions

ISO/IEC TR TECHNICAL REPORT. Information technology Process assessment Part 7: Assessment of organizational maturity

ISO INTERNATIONAL STANDARD. Rubber compounding ingredients Process oils Determination of glass transition temperature by DSC

ISO INTERNATIONAL STANDARD. Safety of machinery Safety distances to prevent hazard zones being reached by upper and lower limbs

ISO INTERNATIONAL STANDARD. Calculation of load capacity of spur and helical gears Part 6: Calculation of service life under variable load

ISO INTERNATIONAL STANDARD. Road vehicles Environmental conditions and testing for electrical and electronic equipment Part 5: Chemical loads

ISO INTERNATIONAL STANDARD. Petroleum and natural gas industries Downhole equipment Packers and bridge plugs

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Earth-moving machinery Determination of average ground contact pressure for crawler machines

ISO INTERNATIONAL STANDARD. Water quality Determination of sulfates Method by continuous flow analysis (CFA)

ISO 5817 INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Titanium and titanium alloys Determination of iron Atomic absorption spectrometry

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Quality management Guidelines for training. Management de la qualité Lignes directrices pour la formation

ISO 2560 INTERNATIONAL STANDARD. Welding consumables Covered electrodes for manual metal arc welding of non-alloy and fine grain steels Classification

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Space systems Programme management Non-conformance control system

ISO 3882 INTERNATIONAL STANDARD. Metallic and other inorganic coatings Review of methods of measurement of thickness

ISO INTERNATIONAL STANDARD. Injection containers and accessories Part 6: Caps made of aluminium-plastics combinations for injection vials

ISO INTERNATIONAL STANDARD. Earth-moving machinery Cable excavators Terminology and commercial specifications

ISO INTERNATIONAL STANDARD. Paints and varnishes Determination of wet-scrub resistance and cleanability of coatings

ISO 4360 INTERNATIONAL STANDARD. Hydrometry Open channel flow measurement using triangular profile weirs

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Visual testing of fusion-welded joints

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ISO 7937 INTERNATIONAL STANDARD

ISO 3846 INTERNATIONAL STANDARD. Hydrometry Open channel flow measurement using rectangular broad-crested weirs

ISO INTERNATIONAL STANDARD. Aseptic processing of health care products Part 4: Clean-in-place technologies

Transcription:

INTERNATIONAL STANDARD ISO 17643 First edition 2005-07-01 Non-destructive testing of welds Eddy current testing of welds by complex-plane analysis Contrôle non destructif des assemblages soudés Contrôle par courants de Foucault des assemblages soudés avec analyse des signaux dans le plan complexe Reference number ISO 17643:2005(E) ISO 2005

PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. ISO 2005 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO's member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyright@iso.org Web www.iso.org Published in Switzerland ii ISO 2005 All rights reserved

Contents Page Foreword... iv Introduction... v 1 Scope... 1 2 Normative references... 1 3 Terms and definitions... 1 4 Personnel qualification... 1 5 Written procedures... 2 6 General applications... 2 6.1 Essential variables... 2 6.2 Additional information... 2 6.3 Surface conditions... 2 6.4 Equipment... 3 6.4.1 Instrumentation (excluding probe)... 3 6.4.2 Surface probes... 3 6.4.3 Accessories... 4 6.4.4 Systematic equipment maintenance... 5 6.5 Test procedure... 6 6.5.1 Procedure for measuring coating thickness and material comparison relative to calibration block... 6 6.5.2 Procedure for testing welds in ferritic materials... 6 6.6 Detectability of discontinuities... 12 6.7 Procedure for testing welds in other materials... 12 7 Test report... 13 Bibliography... 14 ISO 2005 All rights reserved iii

Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 17643 was prepared by Technical Committee ISO/TC 44, Welding and allied processes, Subcommittee SC 5, Testing and inspection of welds. iv ISO 2005 All rights reserved

Introduction Requests for official interpretations of any aspect of this International Standard should be directed to the Secretariat of ISO/TC 44/SC 5 via your national standards body. A complete listing of these bodies can be found at www.iso.org. ISO 2005 All rights reserved v

INTERNATIONAL STANDARD ISO 17643:2005(E) Non-destructive testing of welds Eddy current testing of welds by complex-plane analysis 1 Scope This International Standard defines eddy current testing techniques for detection of surface breaking and near surface planar discontinuities, mainly in ferritic materials (weld material, heat-affected zones, parent materials). Eddy current testing can also be specified for use with non-ferritic materials, for example in an application standard. The techniques can be applied to coated and uncoated objects during fabrication and in service, both onshore and offshore. Eddy current testing can be carried out on all accessible surfaces and on welds of almost any configuration. Unless otherwise specified for specific points in this International Standard, the general principles of EN 12084 apply. NOTE Eddy current testing is usually performed in the as-welded condition. However, the accuracy of the results can be affected by very rough surface finishes. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1330-5, Non-destructive testing Terminology Part 5: Terms used in Eddy current testing EN 12084, Non-destructive testing Eddy current testing General principles and guidelines 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 1330-5 apply. 4 Personnel qualification Non-destructive testing shall be performed by qualified and capable personnel. It is recommended that personnel are qualified in accordance with ISO 9712 or an equivalent standard at an appropriate level in the relevant industry sector. ISO 2005 All rights reserved 1

5 Written procedures If a written procedure is required, it should be prepared in accordance with EN 12084. Otherwise, the procedures detailed in this International Standard shall be followed. 6 General applications 6.1 Essential variables Prior to eddy current testing, the following essential items shall be specified in accordance with EN 12084: certification of testing personnel; testing plan; testing equipment; calibration of the equipment; calibration blocks; acceptance criteria; recording of indications; reporting format; actions necessary for non-acceptable indications. 6.2 Additional information Prior to eddy current testing, the following information should be specified. Further information may be necessary for determination of the nature of the discontinuities and the composition or grade of the parent material: type of filler metal; location and extent of welds to be tested; weld surface geometry; surface conditions; coating type and thickness. 6.3 Surface conditions Eddy current testing can be used to detect surface cracks through non-metallic coatings up to 2 mm thick. For coating thicknesses greater than 2 mm, the sensitivity of the test method shall be demonstrated in advance before eddy current testing is used. NOTE 1 Eddy current testing is dependent on close contact between the probe and the test surface. For effective eddy current testing of welds, it should be noted that local adverse weld form, excessive weld spatter, scale, rust and loose paint can influence sensitivity by separating the probe from the test object and by inducing noisy responses. NOTE 2 It should be noted that some types of conductive coating, such as thermally sprayed aluminium and lead, can seriously influence the results as they can deposit electrically conductive metallic material in cracks open to the surface. Cracks covered with such a metallic deposit are not always indicated by this method. 2 ISO 2005 All rights reserved

6.4 Equipment 6.4.1 Instrumentation (excluding probe) 6.4.1.1 General The instrumentation used for eddy current testing in accordance with this International Standard shall be capable of analysis and display in the complex plane of both phase and amplitude and have at least the following features: 6.4.1.2 Frequency The eddy current instrumentation shall be able to operate at a selected frequency within the range 1 khz to 1 MHz. 6.4.1.3 Calibration of sensitivity levels After balance and lift-off compensation and a further adjustment of the gain and phase controls, a 1 mm deep artificial discontinuity in a calibration block (see 6.4.3.1) shall be indicated as a full screen deflection through a coating thickness corresponding to the maximum expected on the structure to be examined. A 0,5 mm deep artificial discontinuity in the same calibration block shall be indicated as a minimum of 50 % of the signal obtained from the 1 mm deep artificial discontinuity indication through the same coating thickness. Both requirements shall apply to the chosen probe and shall be verified on a relevant calibration block (in accordance with 6.4.3.1). If these requirements cannot be met, eddy current testing is not possible. 6.4.1.4 Signal display As a minimum, the signal display shall be a complex-plane display with the facility to freeze data on screen until reset by the operator. The trace shall be clearly visible under all lighting conditions expected during testing. 6.4.1.5 Phase control The phase control shall be able to give complete rotation (360 ) in steps of no more than 10 each. 6.4.1.6 Evaluation mode The evaluation mode shall use both phase analysis and amplitude analysis of a vector traced to the complexplane display. Evaluation may be by comparison of this display with the reference data previously stored. 6.4.2 Surface probes 6.4.2.1 Probes for measuring coating thickness and material evaluation relative to calibration block To be acceptable for this purpose, the probe shall be capable of providing a full screen deflection lift-off signal on the instrumentation when moved from an uncoated spot on a calibration block to a spot covered with the maximum coating thickness expected on the structure to be tested. The probe shall operate in the absolute mode at a selected frequency in the range from 1 khz to 1 MHz. All the probes shall be clearly marked with their operating frequency range. (See Figure 1.) ISO 2005 All rights reserved 3

Key 0 balance point 1, 2, 3, 4 deflections representing variations in thickness of simulated coatings on calibration block 5 deflection representing material of calibration block 6, 7 deflection representing range of material to be examined using calibration block Figure 1 Coating thickness measurement and material sorting using absolute probe 6.4.2.2 Probes for testing of welds For testing of ferritic welds, probes specially designed for this purpose shall be used. The probe assembly shall be differential, orthogonal, tangential or equivalent, which is characterized by having a minimal dependency on variations in conductivity, permeability and lift-off in the welded and heat-affected zones. The diameter of the probe shall be selected relative to the geometry of the component under test. Such probes shall be able to operate when covered by a thin layer of non-metallic wear-resistant material over the active face. If the probe is used with a cover, then the cover shall always be in place during calibration. The probe shall operate at a selected frequency in the range from 100 khz to 1 MHz. 6.4.3 Accessories 6.4.3.1 Calibration block A calibration block, of the same type of material as the component to be examined, shall be used. It shall have EDM (electric discharge machined) notches of 0,5 mm, 1,0 mm and 2,0 mm depth, unless otherwise specified, for example in an application standard. The tolerance on the notch depth shall be ± 0,1 mm. The recommended width of the notches is u 0,2 mm. An example of a calibration block is shown in Figure 2. 6.4.3.2 Non-conductive flexible strips Non-conductive flexible strips of a known thickness to simulate the coating or actual coatings on the calibration block shall be used. It is recommended that non-conductive flexible strips be multiples of 0,5 mm thickness. 6.4.3.3 Probe extension cables Extension cables may only be used between the probe and the instrumentation if the function, sensitivity and the resolution of the whole system can be maintained. 6.4.3.4 Remote display and control For operation with long extension cables, the equipment shall include a device for remote signal display at the operator's location. 4 ISO 2005 All rights reserved

Dimensions in millimetres Figure 2 Example of a calibration block 6.4.4 Systematic equipment maintenance 6.4.4.1 Calibration certificate The equipment (instrumentation and probe) shall have a currently valid calibration certificate. This may be issued by the manufacturer, a recognized calibration laboratory or an authorized agency. The equipment shall be re-calibrated at least annually. ISO 2005 All rights reserved 5

6.4.4.2 Functional check The equipment shall be checked and adjusted on a periodic basis for correct functioning. This shall only include measurements or adjustments that can be made from outside the equipment. Such adjustments shall be carried out in case of device faults or partial deterioration. Maintenance shall follow a written procedure. The results of maintenance checks shall be recorded. 6.5 Test procedure 6.5.1 Procedure for measuring coating thickness and material comparison relative to calibration block The coating thickness on the unmachined surface of a weld is never constant. As it will influence the sensitivity of crack detection, it is necessary to get an estimate of the maximum coating thickness in the heataffected zone prior to the eddy current testing of the weld. The lift-off signal obtained from the component to be tested shall be similar to the signal obtained from the calibration block, i.e. it shall be within 5 either side of the reference signal (see Figures 1 and 2). In the event that the signal is out of this range, a calibration block more representative of the material to be examined shall be produced/manufactured. 6.5.2 Procedure for testing welds in ferritic materials 6.5.2.1 Frequency The frequency shall be optimized with respect to the sensitivity, lift-off and other unwanted signals. For usual conditions, a frequency of about 100 khz is recommended. 6.5.2.2 Calibration Calibration is performed by passing the probe over the notches in the calibration block. The notched surface shall first be covered by non-conductive flexible strips having a thickness equal to or greater than the measured coating thickness. The equipment sensitivity is adjusted to give increasing signals from increasing notch depths. The 1 mm deep notch shall give a signal amplitude of approximately 80 % of the full screen height. The sensitivity levels shall then be adjusted to compensate for component geometry. A calibration check shall be performed periodically and as a minimum at the beginning and the end of testing and after every change in working conditions. Every calibration check shall be recorded. When the calibration is complete, it is recommended the balance point be adjusted to the centre of the display. 6.5.2.3 Scanning The weld surface and the heat-affected zones shall be scanned with the chosen probe(s). As far as the geometry of the test objects permits, the probe shall be moved in the directions perpendicular to the main direction of the expected discontinuities. If this is unknown, or if discontinuities in different directions are expected, at least two probe runs shall be carried out, one perpendicular to the other. Eddy current testing can be split into two parts: the heat-affected zones (see Figures 3, 4 and 5) and the weld surface (see Figures 6 and 7). It should be noted that the reliability of eddy current testing is highly dependent on the orientation of the coils relative to the surface under test. Care shall be taken to ensure that the probe is at the optimum angle to meet the varying surface conditions in the heat-affected zone. For differential probes, the sensitivity is affected by the orientation of the discontinuity relative to the coil. Therefore, care shall be taken that this is also controlled during testing. 6 ISO 2005 All rights reserved

Key 1 probe direction 2 discontinuity 3 optimum angle to accommodate the varying surface conditions Figure 3 Parent material and heat-affected zone testing ISO 2005 All rights reserved 7

Key 1 probe direction 2 discontinuity 3 optimum angle to accommodate the varying surface conditions Figure 4 Single pass scan in toe of the weld 8 ISO 2005 All rights reserved

Key 1 probe direction 2 discontinuity Figure 5 Additional scans in the heat-affected zone ISO 2005 All rights reserved 9

Key 1, 2, 3 different positions of the probe 4 signal envelope from traversing weld cap Figure 6 Scanning procedure for weld cap testing 10 ISO 2005 All rights reserved

Key 0 balance point 1, 2, 3, 4, 5, 6 different positions of the probe Figure 7 Typical discontinuity signals generated during weld cap scanning ISO 2005 All rights reserved 11

6.6 Detectability of discontinuities The following items which may affect discontinuity detectability shall be taken into account: a) material of calibration block: the material of the calibration block shall be similar to that of the component under test (see 6.5.1); b) conductive coatings: conductive coatings reduce the sensitivity of the test; c) non-conductive coatings: non-conductive coatings reduce the sensitivity of the test depending on the distance between the probe and the component under test; d) geometry of the component: the shape of the component and the access of the probe to the area under test may influence the sensitivity of the test, complex weld geometries such as cruciforms and gusset plates shall be examined relative to the complex geometry and possible orientation of the discontinuities; e) orientation of coils to the discontinuity: 1) inclination: care shall be taken to ensure the optimum angle of the coils relative to the area under test is maintained, 2) directional induced current: the induced current is directional, therefore care shall be taken to ensure that the orientation of the current is perpendicular and/or parallel to the expected discontinuity position; f) minimum size of discontinuity: generally, the minimum size of discontinuity that the eddy current method is capable of detecting in a ferritic steel weld in the as weld condition is 1 mm deep 5 mm long. 6.7 Procedure for testing welds in other materials As previously stated, the eddy current method is also applicable to welds in other metallic materials such as aluminium and stainless steels. The procedure for testing such welds shall generally include the same items as in 6.5.2, but the choice of frequency, probes, calibration and scanning patterns shall be optimized to the actual material, and may deviate considerably from that recommended for ferritic materials. Therefore, the test procedure shall be based on practical experience with suitable equipment, probes and calibration blocks and shall be detailed in a specific procedure. The limiting factors shall be clearly defined in each case. 12 ISO 2005 All rights reserved

7 Test report Before performing eddy current testing, the content of the test report shall be specified using the requirements of EN 12084 for guidance. The test report shall include as a minimum: name of the testing company (if relevant); component identification; material; coating type and nominal thickness (if relevant); heat treatment; type of joint; material thickness; welding process; procedure number; acceptance criteria; surface preparation; the extent of testing with e.g. references to drawings; calibration block description; test equipment; test conditions (e.g. frequency, sensitivity and phase); calibration report; description and location of non-acceptable indications exceeding the acceptance criteria (e.g. by sketching, photographing); results of testing; name of inspector and date of testing; customer's signature and relevant certifying authority's signature (if relevant). ISO 2005 All rights reserved 13

Bibliography [1] ISO 9712, Non-destructive testing Qualification and certification of personnel 14 ISO 2005 All rights reserved

ICS 25.160.40 Price based on 14 pages ISO 2005 All rights reserved