SECTION PERMANENT FORMS - INSULATING CONCRETE FORMS Page 1 of 7

Similar documents
SECTION INSULATING CONCRETE FORMING (ICF)

SECTION PERMANENT FORMS Insulating Concrete Forms Rev

TYPICAL ENGINEERED COMMERCIAL / RESIDENTIAL DETAILS & TABLES

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

Polycrete Big Block Standard Specification

Sept 30, 2004 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

(800) (562) A Subsidiary of the International Code Council

SECTION INSULATED CONCRETE FORMS - RASTRA 1.01 SUMMARY

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

Architectural precast Concrete EARTH FRIENDLY BLOCK

Issue Date: April 2003 Release: I. Product Specifications

Insulated Concrete Forms (ICFs)

Table of Contents. 1 Introduction. 2 Description. 3 Tools and materials. 4 Footings or slabs. 5 Coursing placement. 6 Reinforcing steel

UNIFIED FACILITIES GUIDE SPECIFICATIONS

PART 1 GENERAL RELATED SECTIONS A. Section 03200: Concrete Reinforcement. B. Section 03300: Cast-In-Place Concrete.

Welcome. Integra Products

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: DIVERSIFOAM PRODUCTS EVALUATION SUBJECT:

SECTION INSULATING CONCRETE FORMING (ICF)

INTEGRASPEC. Specify Integrity in your next project: Please visit us at "The User Friendly ICF" PRODUCT LINE.

TECHNICAL EVALUATION REPORT No. 27/2008/2060

High Performance Insulating Concrete Form

Sept 30, 2004 Page 1

General Installation Overview

SECTION THERMAL INSULATION

SECTION NON--STRUCTURAL METAL FRAMING

ICC-ES Evaluation Report Reissued September 1, 2010 This report is subject to renewal in two years.

DMX AG AIR-GAP MEMBRANE. Section Damproofing and Waterproofing

A-ONE Insulated Forms Installation Manual

Expansion Joint Covers (079513)

SPECIFICATION GUIDELINE

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: AMVIC INCORPORATED

Master Specification ENERTITE by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

Master Specification WALLTITE Eco v.3 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

Product Information Bulletin

Master Specification WALLTITE ECO v.2 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

Expansion Joint Covers

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: NUDURA CORPORATION EVALUATION SUBJECT:

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

SPECIFICATION GUIDELINE

"The User Friendly ICF"

SECTION STRUCTURAL INSULATED PANELS

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SECTION TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: SUPERFORM PRODUCTS LTD. EVALUATION SUBJECT:

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

O82018 Hunter Panels XCI Foil

Lamit Industries, Inc. 710 Marion Road Columbus, Ohio P-(614) F-(614)

Evaluation Report CCMC R Superior Walls Xi Precast Concrete Insulated Wall Panels

TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

Union County Vocational - Technical Schools Scotch Plains, New Jersey

5.0 NUDURA PRODUCTS ON SITE STORAGE PACKAGING, UNIT ASSEMBLY, USAGE

PART 1 GENERAL 1.1 SECTION INCLUDES. A. Below grade waterproofing and dampproofing 1.2 RELATED SECTIONS 1.3 REFERENCES

Section 1 - Introduction 1.1 Introduction Welcome to Fox Blocks. You have made an excellent decision to use Fox Blocks Insulated Concrete Forms (ICFs)

The Advantage ICF System. Installation Detail Drawings. The Advantage ICF System. Recommendation: Review the Advantage ICF System Installation Videos.

Design Professional s Guide and CSI Specifications

Before You Get Started, You Will Need

SRP-AirOutshield UV Issued:

I.C.E. BLOCK (U.S. Patent No. 4,223,501) Detail Manual

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

Code Compliance Research Report CCRR-1060

SECTION SPRAY FOAM INSULATION

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

INSTALLATION CHECKLIST 2 ND EDITION. Fox Blocks Abbott Drive Omaha, NE

October 12, Yours very truly, Gary G. Nichols, P.E., SECB Vice President. GGN/md Enclosure Evaluation Committee

Professional Engineers Ontario West Toronto Chapter. Maziyar Bolour, P. Eng.

MASTERFORMAT SPECIFICATION

SECTION EXTERIOR INSULATION AND FINISH SYSTEMS

Closed cell expanded polystyrene (EPS) insulation with graphite.

PRODUCT SPECIFICATIONS

SECTION Arisfor WallGuard

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

SECTION CONCRETE FORMWORK AND ACCESSORIES

SECTION SPRAY FOAM INSULATION

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code

SECTION EMBEDDED CMU/SPLIT FACE ARCHITECTURAL PRECAST/SITECAST CONCRETE. A. Site Cast or Tilt-Up CMU/Split Face Concrete Panels.

SELECT APPROPRIATE SECTIONS FOR BELOW; DELETE OTHERS

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

Construction Standards PAGE

The Perfect Block OEM ICC Equivalent Product Compliance Report

SECTION NON-STRUCTURAL METAL FRAMING

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

GA APPLICATION OF GYPSUM SHEATHING

MID-RISE DESIGN & CONSTRUCTION

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

Arxx High Performance Wallsystems

Deer Ridge Consulting, Inc.

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Important: Before You Start

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

NUDURA FIELD GUIDE CHECKLIST & PROJECT LOG

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

Transcription:

SECTION 03 11 19 (03130). PART 1 GENERAL 1.01 SUMMARY A. Comply with the requirements for Division 1. B. Supply and installation of insulating concrete form system, installation of reinforcing steel and placement of concrete within formwork. C. ICF Manufacture approved bracing and falsework shall be provided by the Installing Contractor to comply with all applicable Codes. 1.02 SCOPE OF WORK A. Furnish all labour (including certified technical support), materials, tools, and equipment to perform the installation of IntegraSpec Insulated Concrete Wall / Building System as manufactured by: Phil-Insul Corporation (PIC) o/a IntegraSpec ICF, 735 Arlington Park Place, Unit 11U, Kingston, Ontario, Canada (800) 382-9102. B. Furnish all labour to include placement of reinforcing steel within forms (as per structural engineer s specifications), placement of concrete in to forms, and final cleanup. 1.03 PRODUCTS SUPPLIED BUT NOT SPECIFIED OR INSTALLED UNDER THIS SECTION A. EPS compatible modified bituminous sheet waterproofing membrane. B. EPS compatible stucco and base coat. 1.04 PRODUCTS INSTALLED BUT NOT SPECIFIED OR SUPPLIED UNDER THIS SECTION A. Sleeves H. Rebar Ties B. Inserts I. Flange Bolts C. Anchors J. Strapping D. Bolts E. Reinforcing Steel F. Window and Door Opening IntegraBucks G. Concrete 1.05 RELATED SECTIONS A. Section 03 20 00 - Concrete Reinforcement (03200) B. Section 03 30 00 - Cast-In-Place Concrete (03300) C. Section 03 40 00 - Precast Concrete (03400) D. Division 04 00 00 - Masonry (04000) E. Division 05 00 00 - Metals (05000) F. Division 06 00 00 - Wood and Plastics (06000) G. Section 07 13 13 - Modified Bituminous Sheet Waterproofing (07130) H. Section 07 24 00 - Exterior Insulation Finishing Systems (07240) I. Section 07 46 00 - Siding (07460) J. Division08 05 00 - Doors and Windows (08000) K. Section 09 20 00-09 25 00 - Portland Cement Plaster (Stucco) and Gypsum Board (09220-09250) L. Section 09 80 00 - Wall Finishes / Acoustical Treatments (09220-09250) Page 1 of 7

1.06 ALTERNATES A. Materials shall be only as specified in Paragraphs 1.02 and 2.02 as per manufacturer specified in Paragraph 2.01. No alternate materials shall be accepted for this Section. B. Any product submitted as equivalent materials must adhere to the minimum standard and criteria as set forth in section 1.09, 1.10, 1.11, 1.12, 2.02, 2.03. 1.07 REFERENCES A. ACI 318 Building Code Requirements for Reinforced Concrete B. ASTM C 578-03 Specification for Rigid, Cellular Polystyrene Thermal Insulation D. ASTM C473 Physical Testing of Gypsum Board Products and Gypsum Lath E. ASTM D1761 Mechanical Fasteners in Wood F. ASTM E84 Surface Burning Characteristics of Building Materials G. UBC 26-3 Uniform Building Code Standard Room Fire Test H. ASTM E119-98 (UBC 8-1), Wall Assembly Fire Resistance I. CCMC 12938-R Evaluation Report J. ICC ES Evaluation Number ESR-1147 K. ISO 9002 L. Intertek ATL SEMKO - Testing of Expanded Polystyrene (EPS) Foam M. Florida Approval FL6236 N. LA Approval RR 25571 O. Ontario Building Code Ruling 12938-R P. CAN/ULC S701-01 Compliance Report Standard for Thermal Insulation, Polystyrene Q. ASTM E119-98, NFPA251, and CAN/ULCS101-M89 2 Hour fire rating for 4" Concrete Core R. ASTM E96-00 Compliance Report Water Vapour Transmission of Materials S. EIFS Category II Construction T. BASF BFL-327 Surface Burning Characteristics Underwriters Lab Listing 1.08 DEFINITIONS A. ICF acronym for Insulating Concrete Form. B. WASS and WASS II Wall Alignment System - a form alignment and scaffold system designed for use with IntegraSpec Insulating Concrete Wall Forms / Building System. C. Contractor Installer- an installation contractor, who has received field On Site training in the installation, concrete pouring, and wall alignment of IntegraSpec Insulating Concrete Wall Forms / Building System (and holds a current IntegraSpec licence administered by IntegraSpec s technical personnel with appropriate grade level for the task ). D. Technical Advisor - a technical representative, usually a staff member of a Distribution Firm, who has received instructional and field training in the installation of IntegraSpec Insulating Concrete Wall Forms / Building System (as accredited by IntegraSpec Insulating Concrete Wall Forms / Building System) and is in the capacity of supervising an installation crew on site and holds a current IntegraSpec licence with appropriate grade level for the task. E. EPS - acronym for Expanded Polystyrene when referencing the insulating foam component of the IntegraSpec Insulated Concrete Wall Forms / Building System. F. Window or Door Opening Buck - a pre-manufactured or site constructed frame assembly consisting of wood, plastic, or EPS material used to form a rough opening within the ICF forming system that will retain concrete around the opening. The frame can also provide for subsequent anchorage of doors and windows within the wall assembly. G. IntegraSpec licence grade levels as follows: Training level A basements and foundations projects; Training level B - residential one level above grade projects; Training level C - install, supervise, and inspect any residential projects; Training level D - install, supervise, and inspect any commercial or residential projects. Page 2 of 7

1.09 SYSTEM DESCRIPTION / PERFORMANCE REQUIREMENTS A. Insulating concrete wall form system shall consist of two flame resistant, bi-directional and reversible panels of Expanded Polystyrene (EPS) connected by high impact polystyrene plastic, slide-in and snap locking spacers (breakable in two equal parts) preventing floatation and compression of the EPS block / panels. B. IntegraSpec panel s to provide a 1" (25 mm) interlock and cut lines pattern. C. IntegraSpec panels can be easily cut horizontally to accommodate various wall heights and or provide exterior forms for concrete floor or roof (panel s cut portion can also be utilized anywhere in the wall due to its reversible feature and slide-in spacers, which also eliminates waste). D. IntegraSpec wall system to provide 4", 5", 6", 8", 10", 12" (102, 127, 152, 203, 254 or 305 mm) or wider by joining IntegraSpec s interlocking spacers within the forms with the Integra H Clip, insulated, even thickness, monolithic reinforced concrete wall (as per structural requirements). E. Wall system to provide locking spacers (top of each other) and inserts with minimum 1⅝" (42mm) wide fastening strips @ 8" (200 mm) o/c, imbedded inside IntegraSpec s EPS panels (to prevent thermal transfer through spacers), to facilitate fastening of the finishing substrate material(s) on both the interior and exterior of the IntegraSpec wall(s). F. Wall system to provide accurate positioning of steel within form cavity in increments of minimum 6" (150 mm) horizontal spacing. Must also conform to reinforcing requirements of ACI 318. G. EPS foam panels with concrete to provide minimum insulation levels as noted: 4" (102 mm) Concrete Cavity Form: R 21.7 (RSI 3.82); 5" (127 mm) Concrete Cavity Form: R 22.0 (RSI 3.87); 6" (152 mm) Concrete Cavity Form: R 22.3 (RSI 3.93); 8" (203 mm) Concrete Cavity Form: R 22.9 (RSI 4.03); 10" (250 mm) Concrete Cavity Form: R 23.5 (RSI 4.14); 12" (305 mm) Concrete Cavity Form: R 24.1 (RSI 4.24). H. EPS foam panels to provide maximum vapour permeance 39.8 ng/pa.s.m 2. I. Finished wall assembly to provide minimum rating of STC 51 (Sound Transmission Class) sound attenuation performance (field test). J. EPS IntegraSpec foam panels to be molded at a minimum of 1.5 lbs/cu/ft in density in accordance with ASTM C 578 03 and ASTM E 84. K. EPS IntegraSpec panels must provide permanent attachment / bonding of the IntegraSpec s EPS panels to the reinforced concrete core through the integral dovetailed grooves molded on the inside face (concrete core side) of IntegraSpec EPS panels. L. Wall assembly (EPS and concrete) must have a fire resistance of minimum 2 hours [4" (102 mm) concrete core], tested in accordance to CAN/ULC S101-M89, NFPA 251, and or ASTM E119-98 (UBC 8-1). 1.10 SUBMITTALS A. Upon request, submit relevant laboratory tests or data that validate product compliance with performance criteria specified prior to commencement of work under this Section. B. Submit copy of IntegraSpec Installation / Product manual. 1.11 QUALITY ASSURANCE A. Contractor shall engage an IntegraSpec field trained Contractor Installer or Technical Advisor with current IntegraSpec licence appropriate for project for the duration of the work under this Section. B. Contractor Installer /Technical Advisor shall furnish proof of IntegraSpec training documentation to Contractor prior to commencement of work under this Section. Page 3 of 7

C. Site Mock-up: If required, construct sample wall mock-up panel to include full wall system and details, located where directed by Consultant. Panel may form part of finished work if approved by Consultant. D. Contractor Installer/Technical Advisor to meet with Contractor prior to material delivery on site to co-ordinate provision of access, storage area, and handling of IntegraSpec product(s). E. Contractor Installer/Technical Advisor to provide a signed IntegraSpec compliance certificate to be completed by the Certified Installer or Technical Advisor at the completion of the ICF portion of the project. 1.12 DELIVERY STORAGE and HANDLING A. Deliver products in original factory UV protected, white plastic wrapped packaging, bearing identification of product, manufacturer, ICC (US) and CCMC (Canada) report numbers, and batch/lot number. B. Handle and store products in location to prevent damaging and soiling. C. UV protection is to be provided for exposed EPS panels and plastic material, should onsite storage extend beyond thirty (30) days. 1.13 PROJECT CONDITIONS A. Use appropriate measures for protection and supplementary heating when required to ensure proper concrete curing conditions in accordance with manufacturer s recommendations if installation is carried out during periods of weather where temperatures are below minimum specified by governing Building Code for concrete and masonry. B. In climates subject to freezing temperature, protect the friction and mechanical interlocks and hollow core of the assembled forms from snow, freezing rain and water by covering these devices nightly. C. All products not in their protective wrapping to be protected daily from the elements. D. Protect the friction and mechanical interlocks from cement during placement of concrete when subsequent wall assembly is to continue to additional levels. 1.14 COORDINATION A. Ensure those materials listed under Sub-Section 1.03 and 1.04 are provided to Contractor Installer prior to commencement of work under this Section. 1.15 WARRANTY A. Contact Distributor or Manufacturer for supply of written copy of specific warranties of the product. PART 2 PRODUCTS 2.01 MANUFACTURER Phil-Insul Corporation (PIC) o/a IntegraSpec, 11U - 735 Arlington Park Place Kingston, Ontario, Canada Toll Free: (800) 382-9102; Fax: (613) 634-2291 Email: info@integraspec.com; Web Site: www.integraspec.com Page 4 of 7

2.02 MATERIALS A. Insulating concrete form panels and locking, slide in spacers shall be IntegraSpec Insulating Concrete Wall Forms / Building System as manufactured by Phil-Insul Corporation, Kingston, Ontario, Canada. B. Form units to be supplied through an authorized IntegraSpec Distributor or Head Office account. C. Substitutes and alternates will not be accepted. (See Section 1.06). D. ICF materials shipped to site to be complete with UV protective wrap. E. ICF standard panels to be shipped in 2' (.609 m) x 2' (.609 m) x 4' (1.2 m) bundles. 2.03 COMPONENTS A. Provide IntegraSpec Insulating Concrete Wall Forms / Building System as listed below as may be required for proper execution of the work: (a) Bi-Directional and Reversible Standard Panels - 48" L x 12¼" H x 2½" thickness (1220 x 311 x 64 mm). (b) Bi-Directional and Reversible 90 and 45 Degree Corner Units 6", 8", and 10" (152, 203 and 254 mm) Concrete Core. (c) Slide in Concrete Spacers - 4", 5", 6", 8", 10", and 12" (102, 127, 152, 203, 254, and 305 mm). (d) Taper Top Panels 48" L x 12¼" H x 2½" tapered to ¾" thickness (1220 x 311 x 64 mm tapered to 19 mm). (e) 4" (102 mm) Brick Ledge Panels. (f) IntegraBucks - 4", 6", and 8" (102, 152, 203 mm). (g) IntegraHeaders 4", 6", 8", and 10" (102, 152, 203, and 254 mm). (h) Integra H Clip joins two or more concrete spacers for wider than 12" (305 mm) concrete cavity. (i) IntegraEnd Cap 6" (152mm). 2.04 CONCRETE A. Concrete supplied under Section 03300 shall be of strength as specified by a design engineer (measured at 28 days). Recommended aggregate size to be ⅜" (10 mm) aggregate for the 4" and 6" (102 and 152 mm) forms and, ¾" (19 mm) aggregate for the 8" and 10" (203 and 254 mm) concrete cavity walls. B. Recommended concrete slump is 4" minimum to 6" +/- 1" (100 mm. to 150 mm +/- 25 mm) (subject to design revision to suit application). 2.05 REINFORCING STEEL A. Reinforcing steel shall be as specified in Section 03210 and shall be supplied under that Section for placement by IntegraSpec s accredited Contractor Installer. 2.06 WALL ALIGNMENT SYSTEM A. To aid in the construction of the IntegraSpec ICF wall system, and to provide an adjustable device for ensuring plumb and straight wall(s) during construction and concrete curing, where appropriate, the WASS and WASS II Alignment Systems (provided as an installation component of the IntegraSpec ICF wall system) shall be used. (WASS and WASS II Alignment Systems are Trade Mark Names of WASS Inc., Canada (613) 835-1699). Page 5 of 7

2.07 WATERPROOFING/DAMPROOFING 2.08 PARGING A. Where called for on drawings, waterproofing or damproofing material used, shall be compatible with EPS such (product such as Peel and Stick Modified Bituminous, sprayed or brush applied Polymeric materials, or other IntegraSpec approved waterproofing material or method, as specified under Section 07130 - Modified Bituminous Sheet Waterproofing A. Where called for on drawings, compatible acrylic or conventional parging (stucco type) approved by IntegraSpec, shall be applied as per the manufacturer s recommendation (application on EPS), as specified under Section 09220-09250- Portland Cement Plaster (Stucco) and Gypsum Board PART 3 EXECUTION 3.01 EXAMINATION A. Inspect all areas included in Scope of Work to establish extent of work and verify site access conditions. 3.02 SITE VERIFICATION OF CONDITIONS A. Verify that site conditions are as set out in Part 1 - General Conditions. B. Examine footings installed under Section 03300 are within +/-¼" (6 mm) of level and that steps in footings are in increments of 12¼" (311 mm) (preferred) in height. C. When specified, ensure reinforcing steel dowels are in place at specified location along footing lengths. 3.03 PREPARATION A. Clean all debris and from top of footings prior to installing the IntegraSpec ICFs. 3.04 INSTALLATION A. Installation of ICF to be in strict compliance with IntegraSpec s Installation Manual as supplied in evidence to contractor under Sub Section 1.10 of this Section. B. Layout of building to be chalked on to the footing. Footprint to be square and true. Full diagonal measurements should be performed or surveyor installed pins should be employed to create accurate square measurements of the building footprint. C. The Installation Contractor shall ensure IntegraSpec procedures for the following work are employed on site (As outlined in the Installation Manual): (a) First and Second Course Placement (b) Horizontal Steel Reinforcement Placement (c) Successive Course Placement (d) Door and Window Opening Construction (e) Door and Window Lintel Steel Reinforcement (f) Complete Service Penetrations (g) Installation of Rim Joist Flange Bolts or Strong Tie (h) Form Alignment and Scaffolding Installation (i) Vertical Steel Reinforcement Placement (j) Pre-Concrete Placement Inspection (k) Concrete Placement (l) Alignment Assembly Removal (m) Site Clean Up (n) Signing of compliance certificate Page 6 of 7

3.05 SERVICE PENETRATIONS A. Service penetrations (e.g. - electrical service conduits, water service pipes, air supply, and exhaust ducts etcetera) shall be installed at the required locations as indicated by the appropriate trade. B. Service penetrations exceeding 16" x 16" (400 mm x 400 mm) in area shall be reinforced. C. Prior to concrete placement, install service penetration sleeves (supplied by others) at designated locations to create access where services can be passed through at later date. 3.06 CLEANUP A. Clean up and properly dispose of all debris remaining on job site related to the installation of the insulating concrete forms. 3.07 PROTECTION A. Recommended temporary coverage onto IntegraSpec ICFs to reduce extended exposure to Ultra Violet Sun light should final finish application be delayed longer than sixty (60) days. END OF SECTION Page 7 of 7