GLASS WALL SPECIFICATIONS

Similar documents
GLASS WALL SPECIFICATIONS

GLASSWALL SPECIFICATIONS

GLASSWALL SPECIFICATIONS

GLASS WALL SPECIFICATIONS

SERIES 631 SPECIFICATIONS

SERIES 641 SPECIFICATIONS

Series 633E SPECIFICATIONS

Series 643E SPECIFICATIONS

Technical Data Sheet Signature 842

ACOUSTI-CLEAR AUTOMATIC SERIES TECHNICAL DATA

Series 3000 Pocket Doors

SPECIFICATION - SECTION (10650) OPERABLE PARTITIONS

Model 2030 Hinged Pairs

Model 2020 Individual Panels / Multi-Directional

Acousti-Seal Encore Paired Panel (10650) Operable Partitions

Series 5550/5551 and Series 5630/5631 Acoustic Glass Walling

632 SERIES SPECIFICATIONS

Model 4010 Individual Panels / Curve & Diverter

SERIES 642 SPECIFICATIONS

2000 POCKET DOOR TECHNICAL DATA

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

Model 3010 Individual Panels / Curve & Diverter

BI-Fold HYDRAU-LIFT SPECIFICATIONS

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND

3000 SERIES POCKET DOOR

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

3030 TECHNICAL DATA Series panels, Hinged in Pairs

2030 TECHNICAL DATA Series panels, Hinged in Pairs. KWIK-WALL... One Source for Wall Systems. SOUND CONTROL

MODEL 3020WT. Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit

KWV-TEC TRIMMED TECHNICAL DATA

Union County Vocational - Technical Schools Scotch Plains, New Jersey

1.1 RELATED DOCUMENTS

Series 600. Operable Partitions

2020 TECHNICAL DATA Series Individual Panels/Multi-Directional. KWIK-WALL... One Source for Wall Systems. SOUND CONTROL

3030 GL TECHNICAL DATA

ACOUSTI-SEAL 900 SERIES TECHNICAL DATA

MODEL KWIK-WALL... One Source for Wall Systems. SOUND CONTROL

MODEL KWIK-WALL... One Source for Wall Systems. SOUND CONTROL

OPERABLE PARTITIONS. Signature

GlassWall. Operable Partitions

Soundmaster & Modernfold TECHNICAL DATA

3020 GL TECHNICAL DATA

3020 TECHNICAL DATA Series panels, Individual Panels/Multi-Directional

A. American Society for Testing and Materials (ASTM):

Acousti-Seal 932. Operable Partitions (10650)

1.1 RELATED DOCUMENTS

SECTION ACCORDION FOLDING PARTITIONS

VARIOTEC - TRIMMED Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit

3010 TECHNICAL DATA Series panels,curve and Diverter. KWIK-WALL... One Source for Wall Systems. SOUND CONTROL

Acousti-Seal 931. Operable Partitions (10650)

ACOUSTI-SEAL 900 SERIES TECHNICAL DATA

Acousti-Seal 933E. Operable Partitions (10650)

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Doc

GlassWall. Movable Partitions

ACOUSTI-SEAL 900 SERIES TECHNICAL DATA

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

5258W WON-DOOR FOLDING DOORS AND PARTITIONS

SECTION OPERABLE PARTITIONS. A. American Society for Testing and Materials (ASTM):

ACOUSTI-SEAL ENCORE SERIES TECHNICAL DATA

MODEL Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit

1.1 RELATED DOCUMENTS

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

ACOUSTI-SEAL 900 SERIES TECHNICAL DATA

2010 TECHNICAL DATA Series Curve & Diverter

AUTOMATIC VERTICALLY RETRACTABLE Skyfold Mirage ACOUSTIC INTERIOR GLASS WALL Section Page 1 October 2017

Model 810 MD Multi- OPTIONS SPECIFICATIONS See page 8 for Product Specifications

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

OPTIONS SPECIFICATIONS See page 6 for Product Specifications

SPECIFICATION GUIDE SLIDING CLOSET DOOR PART 1 - PRODUCT

1.1 RELATED DOCUMENTS

3050 TECHNICAL DATA Series panels. Continuously Hinged/ Electric. KWIK-WALL... One Source for Wall Systems. SOUND CONTROL

SST-II HYDRAULIC BI-FOLD SPECIFICATIONS

Single Panel used with odd numbered panel openings. Single Panel With Expandable Panel - used with odd numbered. panel openings.

MOVEABLE GLASS WALL TECHNICAL DATA

Model 610 MD Multi- Directional. 6 panels. OPTIONS SPECIFICATIONS See page 8 for Product Specifications

SECTION SOUND CONTROL DOORS

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

A DORMA Group Company. Acousti-Clear. Acoustical Glass Wall Systems

Specifications for FL-100 Soffit Panel

ALL-ALUMINUM DOOR & WINDOW FRAMING

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

1 3 4 Tie Rod Aluminum Swing Entrance Doors

SECTION DRYWALL GRID LINEAR LIGHTING INTEGRATION

SECTION ALUMINUM WINDOWS

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SECTION / STC 52 METAL SOUND CONTROL DOORS

SECTION ALUMINUM STORM WINDOWS

Product Guide Specification

SECTION WALL AND DOOR PROTECTION

Model 2030 or 3030 HINGED PAIRS Operable Wall Systems

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

SECTION SECTIONAL OVERHEAD DOORS 511 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION MECHANICALLY ASSISTED MOBILE STORAGE SHELVING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION Motor Operated Horizontal Sliding Sound Control Door

SECTION SECTIONAL OVERHEAD DOORS

Transcription:

GLASS WALL SPECIFICATIONS Series GA2 Ultra Acoustical, STC 45/46 Paired, Glass Wall PRODUCT OVERVIEW: Top Supported Center Stack Paired s Manually Operated Maximum Opening Height: 12' 2 [3.7m] Maximum Opening Width: 26 panels with 2 Lever Closure s STC Rating: 45, 46 Select for Special Needs: Use in areas that you wish to divide with a physical, but not a visual, barrier and where medium sound control is a requirement. Standard Features: The perimeter frame is of steel and aluminum with IG glass units. Paired s: Select for wall-to-wall space division. s are hinged in pairs allowing fast setup. They may be stacked at either or both ends of the track or in a "pocket". How to Obtain: Hufcor partitions are sold, installed, and serviced by factorytrained local authorized Distributors in the United States and by Licensees and Distributors outside the U.S.A. Delivery: s are custom built for your specific project. Lead times vary due to seasonal fluctuations. Check with your Distributor for the current schedule. Warranty: Operable glass partitions are guaranteed against defects in material and workmanship for one year. Product Features and Benefits: Look for these features when comparing similar products. 1. Feature: Top supported Benefit: No need for floor tracks or guides that can gather dirt and dust or cause injury. 2. Feature: Hufcor aluminum tracking systems. Benefit: Proven performance in thousands of movable wall installations around the world. 3. Feature: Hufcor's interlocking vertical rails Benefit: Creates positive interlocking between panels providing stability and ease of panel alignment for superior acoustic seals. 4. Feature: Internal steel frame Benefits: Creates a strong, durable, stable panel. 5. Feature: Up to 2 [51] thick IG Units Benefit: Easy to clean, no inside dirt, and provides superior sound control. Sealed unit, no moisture. Follows IGCC and IGMA certifications. 6. Feature: Dual Laminated Glass Benefit: Safety glass that strongly resists penetration by impacting objects. 7. Feature: Custom manufactured to the exact size of the opening. Benefit: Instead of being locked into pre-determined panel sizes and stack configurations, panels are custom manufactured to fit the opening, allowing for the most flexible configurations. The standard product may be modified to meet individual job site requirements. Contact your Hufcor representative for assistance. F-4402A Figures in brackets [ ] are in millimeters unless otherwise noted. 1

GENERAL SPECIFICATIONS/GLASS WALL Series GA2 Ultra Acoustical, STC 45/46 Paired, Glass Wall PART 1 - GENERAL 1.01 DESCRIPTION A. General 1. Furnish and install operable glass partitions and suspension system. Provide all labor, materials, tools, equipment, and services for glass operable walls in accordance with provisions of contract documents. 1.02 RELATED WORK BY OTHERS A. Preparation of opening will be by General Contractor. Any deviation of site conditions contrary to approved shop drawings must be called to the attention of the architect. B. All header, blocking, support structures, jambs, and track enclosures, as required in 1.04 Quality Assurance. C. Pre-punching of support structure in accordance with approved shop drawings. D. Paint or otherwise finishing all trim and other materials adjoining head and jamb of the partitions. 1.03 SUBMITTALS A. Complete shop drawings are to be provided prior to fabrication indicating construction and installation details. Shop drawings must be submitted within 60 days after receipt of signed contract. 1.04 QUALITY ASSURANCE A. Preparation of the opening shall conform to the criteria set forth per ASTM E557 Standard Practice for Architectural Application and B. Glass shall be safety glass per ASTM C1048-92. C. Partition shall be tested to the ASTM E90-09 standard D. Product to meet ANSI/ASA Standard S12.60, Acoustical Performance Criteria, Design Requirement and Guidelines for Schools. E. Manufacturers must have a quality control system and be ISO 9001:2000 certified or equivalent. 1.05 PRODUCT DELIVERY, STORAGE, AND HANDLING A. Proper storage of partitions before installation and continued protection during and after installation will be the responsibility of the General Contractor. 1.06 WARRANTY. Operable glass partitions shall be guaranteed against defects in material and workmanship for a period of one year. Warranty does not cover glass damage after delivery, abuse or misuse. PART 2 - PRODUCTS 2.01 ACCEPTABLE MANUFACTURERS A. Upon compliance with all of the criteria specified in this section, Manufacturers wishing to bid products similar to the product specified must submit to the architect 10 days prior to bidding complete data in support of compliance and a list of three past installations of products similar to those listed. The submitting manufacturer guarantees the proposed substituted product complies with the product specified and as detailed on the drawings. 2.02 MATERIALS A. Product to be top supported pairs of acoustically insulated glass panels, Series GA2 Ultra, as furnished by Hufcor Inc.. B. Construction 1. s shall be nominally 4 [102] thick and to 48" [1219] in width. 2. s shall be laminated to appropriate substrate to meet the STC requirement in 2.04 Acoustical Performance. 3. Frames shall be of 16 gauge [1.42mm] painted steel with rust inhibitor coating and integral factory applied aluminum vertical edge and face protection. 4. Glazing seals and gaskets shall be snap-on and shaped to suit the glass configuration and thickness. 5. Horizontal Seals a. Models with STC 45: Top and bottom horizontal seals shall be 1" [25] fixed, continuous contact multi-layer vinyl sweep that maintains contact with the track. (1) Option: Bottom horizontal seal shall be 2" [51] fixed, continuous contact multi-layer vinyl sweep. (2) Option: Bottom horizontal seal shall be retractable and provide up to 2 [51] nominal operating clearance, exerting 40 lbs. of downward force when extended. b. Models with STC 46: (1)Top horizontal seals shall be 1" [51] fixed, continuous contact multilayer vinyl sweep that maintains contact with the track. (2) Bottom horizontal seals shall be a combination of fixed, continuous contact multi-layer vinyl sweep and a retractable seal. The retractable seal provides up to 2 [51] nominal operating clearance, and exerts 40 lbs. of downward force when extended. 6. Vertical Seals: Vertical sound seals shall be of tongue and groove configuration, ensure panel-to-panel alignment and prevent sound leaks between panels. 7. Glass: The glass shall be of factory installed nom. 2" [51] dual laminated insulated glass unit. For heights 10' [3048] and over, a horizontal panel splice is required for two glass units. Options: Glass can be customized with decals and etching (requires factory pre-approval) 8. Weight of s: 9.4 lbs./sq. ft. C. Suspension system 1. Track shall be of clear anodized architectural grade extruded aluminum alloy 6063-T6. Track design shall provide integral support for adjoining ceiling, soffit, or plenum sound barrier. Track shall be connected to the structural support by pairs of 3/8" [10] dia. threaded steel hanger rods. Built-in ceiling trim shall be of anodized aluminum finish providing enclosure of plenum sound barrier on both sides of the track for maximum sound control. A section of track will be removable in order to make it possible for a panel to be removed from the track for later maintenance. a. Each panel shall be supported by one 4-wheeled carrier. Wheels to be of hardened steel ball bearings encased with molded polymer tires. 2. Plenum closure (by others): Design of plenum closure must permit lifting out of header panels to adjust track height. Plenum closure required for optimum sound control of partition. 3. Optional Suspension System: a. Unispan available for areas with insufficient overhead support and for select layouts (consult your Hufcor Distributor): The panels shall be supported by the Unispan pre-engineered truss and post system fabricated of steel and aluminum. Unispan is attached to the building structure for lateral support only. The load of the truss and partition is supported by end columns. The columns are connected to floor plates that distribute the load of the system at the floor. D. Finishes 1. trim and exposed metal shall be powdered coated Silver Metallic Textured. a. Optional (upcharge): Customer selected custom color (requires factory pre-approval and may extend lead time) 2. Fixed, continuous contact sweep seals and sound gaskets shall be black E. Available Accessories/Options 1. Pass Door. ADA compliant "U" shaped pass door allows the pass door to be located in any location in the opening. The pass door includes a selfcloser. Hardware consists of a panic bar on one side and turn handle on the opposite side. Options: a. The pass door hardware has turn handle on both sides b. Locks. Optional lock override is available. c. Retractable bumpers to prevent hardware from making contact with glass when panels are stored. 2. Face Options (s) may have partial height glass and standard face options (example: bottom 4' [1219] section of high pressure laminate, vinyl or acoustical fabric and acoustical glass window at the top). 2.03 OPERATION A. s shall be manually moved from the storage area, positioned in the opening, and the closure panel is closed or extended. 1. Retractable horizontal seals shall be activated by a removable quick-set operating handle located a nominal 42" [1.07m] from the floor in the panel edge. Activation of the seals requires approximately 180 degree turn of the handle. B. Final partition closure to be by (select one): 1. Lever Closure with expanding jamb which compensates for minor wall irregularities and provides a minimum of 250 lbs. [113.4 kg] seal 2 Figures in brackets [ ] are in millimeters unless otherwise noted

Series GA2 Ultra Acoustical, STC 45/46 Paired, Glass Wall force against the adjacent wall for optimum sound control. The jamb activator shall be located a nominal 43" [1.09m] from the floor in the panel face and be accessed from either side of the panel. The jamb is equipped with a mechanical rack and pinion gear drive mechanism and shall extend 4-6 [102-152] by turning the removable operating handle. 2. Hinged Closure (Maximum opening width of 7 panels). Full height hinged panel at one end of the opening hinged to a fixed two piece telescopic aluminum jamb and permanently attached in the opening. The hinged panel has top and bottom sweep seals and shall be fitted with a pull handle. The jamb panel requires a floor pin. a. Optional lockset located in Hinged Closure available for models with 1" [25] floor clearance. C. Stack/Store s 1. Retract seals and move to storage area. 2.04 ACOUSTICAL PERFORMANCE A. Supply a copy of the acoustical test report certifying that the partition was tested by an independent accredited laboratory. The partition tested must be fully functional and meet ASTM-E90 09 standard. The test results must be similar to or exceed the performance specified. Sound tests performed on a single panel or on a non-functional partition will not be accepted. Any sound test not showing panel construction details and weight or not disclosing all of the information will not be valid. All equivalence requests must include complete technical information, a list of 3 similar projects already carried out as well as a copy of the appropriate acoustical performance sound test, at least 10 days before closing of the bids. The manufacturers must also guarantee that the products proposed have the same characteristics as the products specified and are in accordance with the drawings. Standard panel construction shall have obtained an STC rating of (select those that apply): 45, 46 PART 3 - EXECUTION A. Installation. The complete installation of the operable wall system shall be by an authorized factory-trained installer and be in strict accordance with the approved shop drawings and manufacturer s standard printed specifications, instructions, and recommendations. B. Cleaning 1. All track and panel surfaces shall be wiped clean and free of handprints, grease, and soil. 2. Cartoning and other installation debris shall be removed to on-site waste collection area, provided by others. C. Training 1. Installer shall demonstrate proper operation and maintenance procedures to owner's representative. 2. Operating handle and owners manuals shall be provided to owner's representative. Type 40 Aluminum track. Standard for weights to 900 lbs. [408 kg]. VERTICAL SECTIONS 2 1/4" [57] 3/8" [10] Ø HANGER RODS BY HUFCOR 3 1/8" [79] CEILING BY OTHERS 4" [102] 8 11/16" [221] 1" [25] 1" [25] Shown with bottom retractable and sweep seals required for STC 46. Optional: Mechanical Bottom Seal No Scale Figures in brackets [ ] are in millimeters unless otherwise noted. 3

DETAILS Series GA2 Ultra Acoustical, STC 45/46 Paired, Glass Wall s Series GA2 Ultra Acoustical, STC 45/46 Paired, Glass Wall s HORIZONTAL SECTIONS Closure with Lever Closure (Expanding Jamb ) 6" [152] NOM. 1" [25] 5" [127] Lever Closure Joint Lead with Bulb Seal Closure with Lever Closure (Expanding Jamb) and Pass Door 6" [152] NOM. 1" [25] 5" [127] Lever Closure Joint Pass Door Handle one side; push bar opposite side Lead with Bulb Seal Closure with Hinged Closure Hinged Closure Joint Lead with Bulb Seal Figures in brackets [ ] are in millimeters unless otherwise noted. 4

LAYOUT OPTIONS Series GA2 Ultra Acoustical, STC 45/46 Paired, Glass Wall Series GA2 Ultra Acoustical, STC 45/46 Paired, Glass Wall Stack Dimensions Closure with Lever Closure (Expanding Jamb) Stack Depth: 4-1/4 [108] per panel + 1 [25] Stack Width: width + 8 [203] finger clearance if in pocket Closure with Optional Pass Door 4-1/4 [108] per Stack Depth: Allow 4-1/4 [108] per panel + 1 [25]. Add for Pass Door: 10 [254] Stack Width: width + 8 [203] finger clearance if in a pocket. + nom. 10 [254] For Pass Door Closure with Hinged Closure 4-1/4 [108] per + 6-1/4 [159] for Hinged Closure Stack Depth: 4-1/4 [108] per basic panel + 11 [279] for hinged closure panel. If using optional pass door, add: 10 [254] Stack Width: width + 8 [203] finger clearance if in pocket 7-1 2 [191] 11 [279] 5 Figures in brackets [ ] are in millimeters unless otherwise noted

Series GA2 Ultra Acoustical, STC 45/46 Paired, Glass Wall ELEVATIONS Heights to 12 2 [371] Hinged Closure Jamb Basic Pass Door Handle one side; push bar opposite side/ Shown with Optional Window Above Door Lever Closure World headquarters: Hufcor Inc. P.O. Box 5591 Janesville, WI USA 53547-0591 1-800-542-2371 ext. 214; 1-608-756-1241 FAX: 1-608-758-8253 E-mail: info@hufcor.com Website: www.hufcor.com The manufacturer reserves the right to improve and change product without notice. F-4402A Figures in brackets [ ] are in millimeters unless otherwise noted 6