RESIDENTIAL RADON LEVELS IN HONG KONG

Similar documents
E!ects of air conditioning, dehumidi"cation and natural ventilation on indoor concentrations of Rn and Rn

An Introduction to Radon

MEASUREMENTS OF RADON ENTRY PARAMETERS IN THE BUILDINGS

The e!ects of covering materials on indoor Rn concentrations in o$ces in Hong Kong

APPLICATION OF A WHOLE ROOM INDOOR AIR QUALITY (IAQ) MODEL. Feng Li 1 and Jianlei Niu 1. Hung Hom, Kowloon, Hong Kong, China

Radon Levels and Indoor Air Quality in Northern Ireland Certified Passive House Buildings

By HANAN MOHAMED DIAB

RADON MITIGATION OF GROUNDWATER AT A COMMERCIAL FISH HATCHERY

Florida Energy Extension Service

BLOWER DOOR METHOD IN RADON DIAGNOSTICS

PROTOCOL FOR RADON MEASUREMENTS IN SCHOOLS AND KINDERGARTENS. Regulations on Radiation Protection and Use of Radiation 4 letter r

DESIGNING COMMERCIAL SUB-SLAB DEPRESSURIZATION SYSTEMS

Dose in Buildings Caused by Built-in Coal-Sags with Elevated 226 Ra Concentration, and the Possibilities of Intervention

Case Study Leaky Single Story High Radon

The feasibility of natural ventilation in plus energy houses in Germany

SOFTWARE TOOL FOR RADON MAPPING AND DOSIMETRIC MODELING

Air Pollution Meteorology

STUDY ON RADON EMANATION FROM SELECTED BUILDING MATERIALS IN Iraqi Kurdistan Region

MEASUREMENTS OF DOSE RATE AND RADON GAS CONCENTRATION IN SCHOOLS AND KINDERGARTENS CONSTRUCTED WITH USING COAL-SLAG AS BUILDING MATERIAL

Testing Is Easy And Inexpensive

Work Package 2: Performance of naturally ventilated buildings

Global Journal of Engineering Science and Research Management

Work Package 2: Performance of naturally ventilated buildings

INDOOR AIR QUALITY AND ENERGY EFFICIENCY IN THE DESIGN OF BUILDING SERVICES SYSTEMS FOR SCHOOL CLASSROOMS

362: Indoor climate control effect of AAC panels as determined by house model measurements and simulations

Building Guide. Colorado Chapter of the International Code Council

The case for research

Building Performance Evaluation

Cost optimal energy efficiency in multifamily houses

BT.D46.DA SOIL GAS MONITORING CARST MEETING APRIL 25, CNIM Group

COMPLEX SYSTEM OF RADON DIAGNOSIS METHODS AND SPECIFIC EXPERIMENTAL AND THEORETICAL PROCEDURES APPLIED IN THE INDOOR BUILDING ENVIRONMENT ABSTRACT

MODELLING THE ENERGY PERFORMANCE OF NIGHT-TIME VENTILATION USING THE QUASI-STEADY STATE CALCULATION METHOD

OPERATION AND CONTROL OF THERMALLY ACTIVATED SLAB HEATING AND COOLING SYSTEMS

Radioactivity. Lecture 17 Radioactivity in Buildings

Prediction of Long-Term Average Radon Concentrations in Houses Based on Short-Term Measurements. Region I Chestnut Street Philadelphia, PA 19107

FAST EVALUATION OF SUSTAINABLE HEATING AND COOLING STRATEGIES FOR SOLAR HOMES WITH INTEGRATED ENERGY AND CFD MODELING

INDOOR AND OUTDOOR PARTICLE MEASUREMENTS IN A STREET CANYON IN COPENHAGEN

Modeling the Housing Energy Efficiency Optimisation in EnergyPlus: The Study of Current Two-storey and New Three-storey Rural Housing in Hong Kong

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

MEASUREMENT OF ""Rn (THORON) USING ELECTRET ION CHAMBERS

Unresolved Issues for Disposal of Radium-bearing Wastes at Hakes Landfill

United States Environmental Protection Agency Research and Development Project Summary. K.L. Revzan, W.J. Fisk, and R.G. Sextro

EFFECTS OF USING LIGHT-WEIGHT CONCRETE ON INDOOR RADON CONCENTRATION IN HIGH-RISE BUILDINGS

TEXAS FACILITIES COMMISSION Edit Date: 4/13/2012 ARCHITECTURAL/ENGINEERING GUIDELINES

COMPARATIVE SUMMER THERMAL AND COOLING LOAD PERFORMANCE OF NATURAL VENTILATION OF CAVITY ROOF UNDER THREE DIFFERENT CLIMATE ZONES

gskin Application Note: U-Value Measurement Case Study

Variables affecting indoor air quality in newly finished buildings- a multivariate evaluation

Internal heat gain assumptions in PHPP

Acoustics, Ventilation and Overheating Residential Design Guide

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

Deakin Research Online DDeakin Research Online Research Online This is the authors final peer reviewed (post print) version of the item published as:

National University of Singapore

In-vehicle / Out-vehicle air quality and commuter s exposure to pollutants

Annual inhalation dose of indoor radon in dwellings in Aizawl City, Mizoram, India

Variation in Heat gain through the roof of a building due to changes in Solar reflectance. Neville Selby ( B. Eng )

Indoor Building Survey and Product Inventory

BRE Energy Efficient Office of the Future

Estimating the Concentrations of Soil Gas Pollutants in Housing

Building & Fire Appeals Board

VENTILATION STRATEGIES AND MEASUREMENT TECHNIQUES 6th AIC Conference, September , Netherlands

Compliance to the IgCC. September 29, 2011

Canadian Radon Program - Measurement

ENERGY ANALYSIS AND ENERGY CONSERVATION OPTION FOR THE WAREHOUSE FACILITY AT THE HUMAN SERVICES CENTER COMPLEX DRAFT REPORT.

Rapid Building Thermal Diagnosis: Presentation of the QUB Method

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

THE INSTITUTE OF REFRIGERATION

REAL-TIME CONTROL OF OCCUPANTS THERMAL COMFORT IN BUILDINGS. Galway, Ireland

Standard practice for installing cellulose building insulation

Concentrating on Curie-ous Cows LinkedIn Article February 17, 2016 Caoimhín P. Connell Forensic Industrial Hygienist

ENERGY EFFICIENT AIR QUALITY CONTROL IN LABORATORIES USING BENCH EXHAUSTS

When Building a New Home

Construction Studies Theory - Higher Level

Chapter 6. Space heating load

Indoor radon measurements in Erzurum province of Turkey

Exterior Perspective, East End

J.F. Burkhart and R.E. Camley Physics Department University of Colorado-Colorado Springs

Energy and the Built Environment

GREEN CONCEPT OF THERMAL COMFORT DESIGN FOR SUSTAINABLE HOUSING IN THE TROPICS: Learning from Thermal Comfort in School Buildings 1 INTRODUCTION

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM AND HEAVY MASS BUILDING IN BELGRADE

Advanced Ventilation Technologies

Notes. Lesson overview. This lesson discusses how radon enters a home, where people can be exposed to unhealthy levels.

Radon. The Effect of Retrofitting Thermal Insulation

Chapter 7. Passive Solar Contents

For all those with the ability to influence the design, layout or indoor air quality of buildings

Measurement in schools and kindergartens in different town and regions in Bulgaria

Noise Assessment Report

Numerical Investigation on Ventilation Strategy for Laboratories: A Novel Approach to Control Thermal Comfort Using Cooling Panels

Indoor air quality influenced by ventilation system design

ARPAN JOHARI. Architect. 13/08/10 AW Design. Ahmedabad

The influence of opening windows and doors on the natural ventilation rate of a residential building

SURVEY ON INDOOR AIR QUALITY IN CONTEMPORARY RESIDENTIAL BUILDINGS IN JAPAN

The research and simulation on passive solar house with the attached. sunspace in Beijing

Conversion Design of Solar Houses from Active to Passive

Dose assessment from radon in tourist caves

OPEN COMPETITION Energy Design of High Performance Buildings Organised by EC-JRC and ESRU

Human response to individually controlled micro environment generated with localized chilled beam

CHARACTERIZATION OF NORM CONTAMINATED SITES AT THE SYRIAN OILFIELD: SAMPLING, ANALYSIS AND DATA MANAGEMENT

Nearly Zero Energy Building in Lecco Modern technological building compared to an ancient Villa

EFFECT OF MOISTURE AND ADDITIVE ON RADON EXHALATION RATE FROM CONCRETE

ENERGY STAR Qualified Homes National Program Requirements, Version 3.0

Transcription:

RESIDENTIAL RADON LEVELS IN HONG KONG Derek R. Lane-Smith NITON Corporation Bedford, MA ABSTRACT Hong Kong is made of concrete, which emits radon continuously. The radon concentration in a domestic apartment is controlled, to a great extent, by natural ventilation. At night, when outside natural convection dies away, the ventilation rate inside a closed room can drop to near zero. The radon concentration then increases at a steady rate, often to unacceptably high levels. In a poorly ventilated room, the equilibrium radon level can actually give a measure of the ventilation rate. The results in this paper provide a case study for such an approach. The method described also provides a means to determine the minimum veutilalion rate necesy to keep the radon concentration below the mmmended level. For the mom studied, an air change rate of 0.5 changes per hour would keep the radon level less than 100 ~ ~ l(2.5 r pcifl) n above ambient. INTRODUCTION Even with all windows and doors closed, the average apartment, with its loose fining windows, gaps round the air conditioners and gaps under doors, will be subject to infiltration of outside air. Infiltration is driven by pressure differences across the building, caused by wind Sometimes, however, particularly at night when the ground is cooled, all convective activity ceases, and winds drop to zero. There is an English expression describing this.. "In the Still of the Night". Hong Kong is a concrete city. Almost all the high-rise buildings are of ferro-concrete construction. Everybody spends most of their time surrounded by concrete walls, floor and ceiling. The granite aggregate in the concrete contains Uranium and its daughter. Radium, which thus provides a continuous, unchanging source of Radon gas (1). Infiltration normally provides sufficient natural ventilation to keep radon levels below the Environmental Protection Department's action level of 200 ~ q(5.4 h pci/l) ~ (2). On several occasions in a bedroom in my own apartment, however, levels climbed steadily overnight, to peak above 400 13q/m3 and once, at least, exceeded 600 Bqh3 (16.2 PC&) (3). It was obseived that, during the 9 climb of radon level, the rate of increase was always around 40 l3q1m3 (1.1 pck) per hour. This compares with 60 Bq/m per how observed elsewhere in Hong Kong (4). Measurements of ventilation rate by tracer gas may not always be feasible, especially for domestic occupants. In this study, an alternative method is suggested for estimating ventilation rate from time-resolved measurements of the radon concentration. METHODS Methodology The radon concentration was measured continuously in a bedroom. Typically, each measurement run lasted 2 to 3 days and the cycle time was 1 or 1.5 hours. During the early stages of the experiment, measurement runs were started without particular preparation, other than making sure the windows and door were shut. Later in the series, before each measurement run, the room was opened up fully, with windows and door wide open. So the initial radon concentration in the room was the same as outside air (which was in most cases less than 40 ~ qlm (1 PC&)). 1997 International Radon Symposium I1-7.1

When infiltration ceases, radon concentrations outside the room being studied do not effect the level in the room. If infiltration does occur it will have the effect of slowing and limiting the increase of radon concentration in the room By focusing on the maximum slew rate, it becomes unnecessary to monitor levels outside the room being studied. The effect observed is generated entirely within the room under study. Measurements of concentrations both outside the room and outside the apartment were made, but are not of direct relevance to the conclusions of the study. A measurement was made of the radon emission from the wall of the room. A container was sealed against the wall and the air in the container was drawn through the radon monitor. A linear increase in radon concentration was observed for over twelve hours before the rate of increase started to slow down. The initial slope provided a measure of the radon emission. The measurement was repeated several times with nearly identical results. Instrumentation It was necessary to find a radon monitor which would give good time resolution of the measurements. In the radon decay chain the first daughter. Polonium 21 8, has a half-life of 3.05 minutes and decays with a 6.00 MeV alpha particle. The Polonium 214 daughter appears some 45 minutes later and generates a 7.69 MeV alpha particle. An instrument was required, therefore, which (a) filtered out all pre-existing radon daughters and accepted only radon gas into the measurement chamber, (b) captured the Polonium 21 8 atoms created in the measurement chamber and 0 could discriminate between the 6.00 MeV alpha particles from the Polonium 21 8 and the 7.69 MeV alpha particles arising from the Polonium 2 14 much later. The NITON RAD7 radon monitor provided the functionality required. It has several modes of operation and in one, "Sniff Mode", it counts only the 6.00 MeV alpha particles produced by the short-lived Polonium 2 18 and thus has a response time of only about 10 minutes for a 90% response to a step change in radon concentration, either up or down. During a linear ramp lasting several hours, the ten-minute response time has the effect of delaying the readings by ten minutes but does not alter the slope of the ramp, which is the parameter of interest (5). Location The room chosen for the investigation, in an apartment occupied by the author, was on the fifth floor of a 43-floor apartment building in Tseung Kwan 0, East of Kowloon, Hong Kong. The building is made of reinforced concrete and has eight apartments on each floor. The room had an emulsion paint on the walls that is probably quite porous to radon. It is a small bedroom with casement windows and a small air conditioner. During the measurement, the windows and door were closed, but no attempt was made to hermetically seal the room. Thus the occasional cessation of infiltration, occurring at night, was typical of what may be observed in any of millions of other similar rooms with their windows and doors closed. RESULTS Radon concentrations A typical run inside the room with door and windows closed, starting late on 24 October 1995, shows apparently random variations. Note that even on just a typical day the radon level is often close to or even above 200 ~ ~lrn' (5.4 pci/l), the EPD level of concern (2), although a charcoal test would show the average to be acceptable. 1997 International Radon Symposium I1-7.2

Typical Days Figure 1. Radon concentration in bedroom ventilated by natural infiltration. Outside air at the height of the apartment (about 30 m) was invariably very low in radon (less than 20 ~ ~ or 0.5 / pcil). m ~ On July 25 & 26, 1995, it looked like this: ~~/rn' Outside Air at 30m Figure 2. Outside air radon concentration at 30m height There were many occasions where the results demonstrated the linear ramp in radon concentration inside the closed bedroom after dark. A few follow: Figure 3a Examples of linear ramps in radon concentration after dark 1997 International Radon Symposium II - 7.3

~q/rn= Radon Figure 3b. Examples of linear ramps in radon concentration after dark 1 Bq/rn3 Radon Figure 3c. Examples of linear ramps in radon concentration after dark. The mean slope of the four ramps illustrated is 38 ~ ~ (1 / pci/l) m per ~ hour with a standard deviation of less than 10%. The room dimensions were 1.8 m x 2.1 m x 2.4 m. The window at one end took up wall space but was placed protruding 500 mrn beyond the face of the wall. The extra surface created around the window just about compensated for the loss of concrete surface due to the window. The floor was covered in wood blocks and heavily sealed with pofyurethane. It was considered to be sealed against the emission of radon from the concrete floor beneath the surface. The volume of the room with the window recess was 10 m3. The surface area of radon-emitting concrete was 23 m2. Radon emission To measure the emission of radon from the wall, a container with an aperture of 0.17 m2 and a volume of 0.044 m3 was sealed against the painted, concrete wall. Tubes to and from the RAD7 radon monitor were attached to "feedthroughs" mounted in either side of the container. The RAD7 and tubes added a farther 0.001 m3 to the effective volume of the container. 1997 International Radon Symposium 11-7.4

Several runs were made in the emission measurement configuration. One such follows: Radon emission Fig 4. Measurement of radon emission from the wall. The initial slope, averaged over the first ten hours, is 80 ~ ~ (2.2/ pci/l) m per ~ hour. Calculation A room of 10 m3 experiencing a rate of increase in radon concentration of 38 ~q/ro~ per hour must have 380 Bqh entering it If there are 23 m of wall space emitting radon at the same rate and if that is the only source of radon, then each square metre must be emitting 380/23, or 17 Bq per hour. A container of 0.045 m3 experiencing a rate of increase in radon concentration of 80 ~ q/m~ per hour must have 3.6 Bqhr entering it If there is an emitting surface of 0.17 m2 then the rate of emission must be 21 ~ ~ per / hour. m ~ DISCUSSION Within the uncertainties of the experiment, the deduced rate of emission from the walls and the measured emission from the walls are in reasonable agreement. The wall emission measurement was made at a place where a major construction pillar of the high-rise building was situated. It is likely that the surface there, with the thick concrete behind it, will emit more radon than a concrete wall separating two rooms. Further study would show whether or not there is much variation from place to place around the walls and ceiling of the room. If there is variation, it is likely that the room average would be lower than the 21 ~ ~ per / hour m measured, ~ in which case the agreement between the two investigations would likely be even more close. In a high-rise concrete residential building in a hot climate, without central HVAC, it may be concluded, therefore, that the radon levels in a closed room are caused by emission from the walls and pillars of the building itself and are normally limited by infiltration of outside air. However, occasionally, when outside convection dies away and there is no wind, infiltration will cease and radon levels in the room will climb at a rate determined by the emission of radon from the walls. These circumstances may cause highly elevated radon levels which are hazardous to the health of the occupants. The maximum rate of rise of radon concentration, or maximum slew rate, is an indirect measure of the radon emission rate from the walls, floor and ceiling of the room. 1997 International Radon Symposium 11-7.5

Ventilation It may be noted that if the radon concentration stabilises at some steady level, then the rate of supply of radon by emission is e& to the rate of removal by ventilation. We may see, therefore, that the air change causing the stabilization will equal the maximum ramp slope at zero ventilation (in this case 38 Bq/m3 per hour) divided by the equilibrium, excess radon concentration in ~ qlm~. Air Change Rate = (Maximum ramp slope)/(equilibrium radon - outside radon levels) If the outside air is presumed zero Bq/m3 then the calculated air change rate is a lower limit. The same equation may be used to calculate the ventilation necessary to keep the radon level below a given threshold. For example, if we choose a maximum of 100 Bq1m3 (2.5 pci/l) above the ambient as the target concentration and 40 ~ ~ / m ~ (1 pci/l) per hour as the observed maximum slew rate with zero ventilation, then 401100 (1f2.5) or 0.4 ACH is the minimum air change rate necessary to meet the target. REFERENCES 1. Guen Z.J.,Yu K.N. and Young E.C.M., 1991. Field Measurements of Radon Exhalation Rate from Building Surface in Hong Kong. City University of Hong Kong, Research Report AP9 1-01. 2. Interim Indoor Air Quality Guidelines for Hong Kong. 1994. Report No. EPD-TP/1194, Hong Kong Environmental Protection Department 3. Pang W.W. and Pun W.M. April, 1994. Tenitoiy-wide Indoor Radon Survey 1992/93, Report No. EPD-TPI3194, Hong Kong Environmental Protection Department. 4. Yu K.N. and Stokes M.J. 1988. A review of radon issues in Hong Kong, Proceedings of POLMET 88, vol. 2., City University of Hong Kong. 5. RAD-7 Radon Detector Owner's Manual, Niton Corporation. 1997 International Radon Symposium II - 7.6