Understanding GxP Regulations for Healthcare

Similar documents
Visualize Your Compliance

Could Poor Temperature Data Management be Putting Your GxP Facility at Risk for Data Integrity Violations? we prove it.

Risk-based Approach to Part 11 and GxP Compliance

New Data Integrity Regulations and Practical Advice for Life Science Laboratories. we prove it.

Demystify Governance, Risk & Compliance For Lifesciences

[ WHITE PAPER ] A Basic Overview: Meeting the PIC/S Requirements for a Computerized System INTRODUCTION GOOD MANUFACTURING PRACTICES

CUSTOMER AND SUPPLIER ROLES AND RESPONSIBILITIES FOR 21 CFR 11 COMPLIANCE ASSESSMENT. 21 CFR Part 11 FAQ. (Frequently Asked Questions)

DATA INTEGRITY IN CLINICAL RESEARCH. Singapore Clinical Research Professional (CRP) Forum 25 August 2017

Data Integrity Through the Life Cycle Balancing Quality and Innovation. Sion Wyn Conformity +44 (0)

DATA INTEGRITY ASSURANCE AS KEY FACTOR FOR SURVIVING CORPORATE AUDITS AND REGULATORY INSECTIONS

Ensure Data Integrity Compliance Enterprise-Wide

LEVERAGING YOUR VENDORS TO SUPPORT DATA INTEGRITY:

WHO SAYS COMPLIANCE NEEDS TO BE COMPLICATED?

Contents. Primer Series: HIPAA Privacy, Security, and the Omnibus Final Rule

GxP Auditing, Remediation, and Quality System Resourcing

ICH E6 Guideline R 2 優良臨床試驗指引修改及增編附錄

ISPE NORDIC COP CLEAN UTILITIES SEPTEMBER TUUSULA FINLAND. Timo Kuosmanen STERIS Finn-Aqua

GxP Auditing, Remediation, and Staff Augmentation

The Role of the LMS in 21 CFR Part 11 Compliance

Oracle Tech Cloud GxP Position Paper December, 2016

COMPUTERIZED SYSTEM VALIDATION

Regulatory Overview Annex 11 and Part 11. Sion Wyn Conformity +[44] (0)

Addressing the Paradigm Shift in Regulatory Inspections

Regulations in Pharmaceutical Laboratories

GAMP5 Validation for Dynamics 365

Computer System Validation Perform a Gap Analysis of your CSV Processes

GxP Auditing, Remediation, and Staff Augmentation

AWS Life Sciences Competency Consulting Partner Validation Checklist

Introduction to 21 CFR 11 - Good Electronic Records Management

Data Integrity in GXPs

SOLUTIONS FOR SHAREPOINT & OFFICE 365

EU Annex 11 US FDA 211, 820, 11; other guidelines Orlando López 11-MAY-2011

Summary of Significant Changes. Policy

Data Integrity Why is it important? DADM Conference - 22 August 2017

CSV Inspection Readiness through Effective Document Control. Eileen Cortes April 27, 2017

GCP Basics - refresher

References Concept. Principle. EU Annex 11 US FDA , (g), (i), 11 Orlando Lopez 2/15/11. Old Annex 11.

LEGAL REQUIREMENTS and DATA INTEGRITY...

Computers and E-documents in a regulated environment

Research Professionals Network Workshop Series

5-Step Guide For GDPR Compliance

Use of computerised equipment, software and systems in clinical research

Pharmaceutical cgmps for the 21st Century February 2004

Design Qualification SOP

Strategies for Risk Based Validation of Laboratory Systems

21 CFR Part 11 Compliance for SaaS/Cloud Applications

VALIDATION READY IT PROJECTS OF BEAS INDUSTRY SOLUTIONS BASED ON SAP BUSINESS ONE

Reduce costs for compliance with data integrity: 21 CFR Part 11, SaaS/Cloud, EU GDPR

How to support compliance with GAMP 5

How to support compliance with GAMP 5

EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL. EudraLex The Rules Governing Medicinal Products in the European Union

A Comprehensive Approach to Find and Remediate Data Integrity Problems

Application Decommissioning in Regulated Industry

Electronic Records and Electronic Signatures (21 CFR Part 11)

Case Study. Actelion s Quatro System: MasterControl by Any Other Name Stands for Compliance and Efficiency

Good Clinical Practice (GCP): how does a laboratory that supports a clinical trial ensure compliance with these Regulations

Honeywell Software Service Tools Help Manage Control System Performance, Security and Process Plant Outcomes

Infor CloudSuite Industrial

Source Documents Elettronici: Criticità Applicative e approccio alla convalida. Paolo Morelli CEO - Arithmos

Develop a Roadmap for the Implementation of a Global CSV Program. Eileen Cortes April 26, 2017

21CFR11 Compliance and Automated Manufacturing

EU Annex 11 US FDA , (g), (i), 11 Orlando López 09-APR

QA Services. Global. GCP - GVP - GLP - GMP Audits Computer System Compliance Mock Inspections SOP Development Benchmarking and Risk Management

SIEM Buyer s Guide. The Security Challenge Today

Case Study. Actelion s Quatro System: MasterControl by Any Other Name Stands for Compliance and Efficiency

Data Reliability - Internet

Clarity CDS since version 7.2 supportive tools for compliance with Title 21 CFR Part 11, EudraLex Chapter 4, Annex 11 and other similar legislation

ALCOA AND DATA INTEGRITY: PASTAND FUTURE

Global Compliance Trends and Warning Letters

MEDICAL DEVICE CLINICAL INVESTIGATIONS AND ISO 14155

Guidance for Industry - Computerized Systems Used in Clinical Trials

Your Complete Quality Solution Provider for the Life Science Industry

Quality & Safety GLP. 44 q&more 02/14

Agilent OpenLAB Enterprise Content Manager (ECM) THE LABORATORY DATA HUB

Computerised Systems. Inspection Expectations. Paul Moody, Inspector. 18/10/2013 Slide 1. ISPE GAMP COP Ireland Meeting, Dublin, 17 th October 2013

Inspection Trends. American Society for Quality Richmond, VA Section March 8, 2016

Warehouse Monitoring & Mapping

Computer. Systems Validation (CSV) Full Time Part Time Online.

PAI Inspections, Observations and Data Integrity

Computerised Systems. Alfred Hunt Inspector. Wholesale Distribution Information Day, 28 th September Date Insert on Master Slide.

Curriculum Vitae Dr. Joachim Schoch-Bösken. jsb-validierung Zwischen den Bächen 9 D Rheinfelden

Library Guide: Active Pharmaceutical

Hetero Drugs Limited

Process ERP, an ideal software solution for Life Science industries

Lessons from Pharmaceutical Laboratory related FDA Warning Letters

John D. Halamka, MD, MS

Atlant s atwatch CAPA TM. Corrective and Preventive Action System (CAPA) Product & Services Bundle for

THIRD PARTY VS SAP SOLUTION MANAGER FOR SAP CYBERSECURITY PROTECTION

Sarbanes-Oxley Compliance Kit

RSA ARCHER IT & SECURITY RISK MANAGEMENT

Performing Multiple Regulatory Requirements within a Program Such as GMP, GLP, GCP, Medical Devices, and/or Controlled Substances

WCG ACADEMY COURSE OVERVIEW

Symphony Genomics Workflow Management System Managing, Integrating, and Delivering Your NGS Data and Results

2012 Honeywell Users Group EMEA. Sustain.Ability. John Schofield, Honeywell Improved Reliability, Safety and Compliance with Management of Change

Case Study. Flexibility and Audit-Readiness Give Compounding Companies a Competitive Advantage

Understanding Validation Cost. Ivan Soto

Labeling Best Practice in a Challenging Manufacturing Landscape A survival guide for pharmaceutical companies

Implement Effective Computer System Validation. Noelia Ortiz, MME, CSSGB, CQA

IBM Clinical Trial Management System for Sites

Transcription:

Understanding GxP Regulations for Healthcare GxP Guidelines What is GxP? GxP is a collection of quality guidelines and regulations created to ensure that bio/pharmaceutical products are safe, meet their intended use, and adhere to quality processes during manufacturing, control, storage, and distribution. GxP was established by the Food and Drug Administration (FDA) and encompasses different standards recognized as: G stands for Good P stands for Practice x variable depending on the application. It can be M for Manufacturing, C for Clinical, L for Laboratory, S for Storage, D for Distribution, R for Review, etc.

Understanding GxP Regulations for Healthcare 2 GxP ensures that regulated organizations comply with specific and secure manufacturing and storage processes and procedures which determine effective research standards for non-clinical laboratory trials and safe human-subject clinical trials. GxP s guidelines focus on 1: Traceability: the ability to reconstruct the development history of a drug or medical device. Accountability: the ability to resolve who has contributed what to the development and when. Data Integrity (DI): the reliability of data generated by the system. DI could be determined by the following activities: Identifying the data generated by the system during critical processes (data flow diagram) Defining the DI requirements (e.g. ALCOA data attributes) during the lifecycle of data Identifying the risks and mitigation strategies (e.g. technical or procedural controls) to avoid DI breaches. Who is impacted by GxP? Regulated industries including food, pharma, medical devices, and cosmetics are impacted by GxP. GxP guidelines and regulations are global; some of the popular regulators include FDA in the US, TGA in Australia, and HS-SC in Canada. GxP includes varied regulation sets, but the most common are GCP, GLP, and GMP: GCP (Good Clinical Practice) GCP is an international quality standard that is provided by the International Conference on Harmonisation (ICH), an international body that defines standards which governments can transpose into regulations for clinical trials involving human subjects. It controls experimentation on humans done for the sake of advancement in medical sciences and serves as a quality benchmark as well as a moderator that keeps such experimentation in check. GLP (Good Laboratory Practice) GLP is the non-clinical counterpart for GCP. These guidelines apply to non-clinical studies conducted for the assessment of the safety or efficacy of chemicals (including pharmaceuticals) to humans, animals, and the environment. GMP (Good Manufacturing Practice) GMP consolidates the practices required to conform to the guidelines recommended by agencies that control authorization and licensing for the manufacture and sale of food, drug, and active pharmaceutical products. These guidelines provide minimum requirements that a pharmaceutical or a food product manufacturer must meet to ensure that the products are of high quality and do not pose a risk to the consumer or public. Good manufacturing practices, along with good laboratory practices and good clinical practices are overseen by regulatory agencies in the United States, Canada, Europe, China, and other countries. The most common GMP guidance documents are: EU Good Manufacturing Practice (GMP) Guidelines, Volume 4 US FDA current Good Manufacturing Practice (cgmp) guidelines: 21 CFR Part 11, 210, 211, and 820 WHO Good Manufacturing Practices for pharmaceutical products, Annex 4 to WHO Technical Report Series, No. 908, 2003

Understanding GxP Regulations for Healthcare 3 ClearDATA Advantage ClearDATA Compliance & Security Monitoring Dashboard Key Scorecard Metrics & Features Encryption Verification: Validate that your storage medium is successfully encrypted to ensure compliance for FDA 21 CFR Part 11.30. Login & Log Monitoring: Quickly identify and mitigate the risk of unauthorized system access to ensure compliance for FDA -- 21 CFR Part 11.10(g). With healthcare transformation moving at a rapid pace, compliance and security monitoring across the healthcare enterprise is a major HIT challenge. ClearDATA Compliance and Security Dashboard simplifies adherence to administrative, physical and technical safeguards. Our Dashboard is mapped directly to HIPAA and FDA and GDPR guidelines.* It can be enabled across different cloud environments and easily monitor thousands of components, providing unique individual asset scorecards as well as a wide variety of additional reports. *coming soon Log Retention: Securely retain six-years of access logs with automated validation to ensure compliance for FDA -- 21 CFR Part 11.10 (e). Patch Level Reporting: Receive notifications when new patches become available and quickly track previous updates to ensure compliance for FDA 21 CFR Part 820.30(i). Backup Validation: Monitor and validate backups to ensure they were successful. Receive real-time notifications in the event of a failure to ensure compliance for FDA -- 21 CFR Part 11.10 (e). Virus Scan/Intrusion Detection Status: Monitor and validate that a daily vulnerability scan has been performed on each asset to ensure compliance with FDA 21 CFR Part 11.10(h).

Understanding GxP Regulations for Healthcare 4 GxP Readiness Checklist Partner with a healthcare expert/managed service provider to address the following items: 1. Define Quality System Regulation (QSR) gaps 2. If applicable, discuss how to perform a Computer System Validation (CSV) 3. Ensure that the following controls and procedures are implemented: a. Backup and Recovery b. Contingency Plan c. Disaster Recovery d. Change Control Management e. Configuration Management f. Error Handling g. Maintenance and Support h. Corrective Measures i. System Access Prepare for your GxP Validation Process: 1. Decide which GxP guidelines apply to you 2. Decide how your technology maps to GxP guidelines 3. Define User Requirements a. What are your user needs? 4. Functional Specifications a. What will be automated? 5. Solution Analysis a. Validation of your system 6. Build and Construction a. System detailed design specifications b. System test procedures c. Quality review

Understanding GxP Regulations for Healthcare 5 7. Implementation a. Preparation b. Data Migration (legacy systems) c. Production d. Roles and Responsibilities 8. Establish change control process a. Establish change control logs b. Establish patch/upgrade logs 9. Access Control System 10. Configuration Management a. Establish change control logs Prepare for your GxP Validation Process (continued): 11. Audit Trails a. Secure, computer-generated and time-stamped 12. Archive/Backup/Recovery a. Availability and Continuity Plan b. Accurate and complete records c. Ability to retrieve records d. Backup Restoration Protocols 13. Security Controls a. Encryption (rest and transit) b. Network encryption c. Intrusion detection d. Virus scanning 14. Quality System Gaps a. Security and Compliance Audit Process 1 Pharmaceutical Computer Systems Validation: Quality Assurance, Risk Management and Regulatory Compliance, 2016 Need help with GxP? Contact us at https://www.cleardata.com/contact/