Hg CEMS Improvements and Updates

Similar documents
Mercury CEMS Sample Line Temperature Reduction Study

Continuous Emissions Monitoring in Support of the Cement MACT

Mercury Monitoring in a Cement Kiln

"MARAMA/ICAC Mercury CEMS Webinar" Tuesday, July 26, 2011

Mercury Control Technology Development in the Laboratory: International HgCEM Research and Development Applications

Presentation Overview Air Quality Regulations Evolution in the U.S. Summary of Current NESHAPS Regulations Mercury Emissions Control and Measurement T

Mercury Measurements and Control

Continuous Mercury Monitoring at Cement Plant

Mercury Monitoring Technologies and Detection Principles

CEMS for Measurement of Ammonia, SO 3, and Low Level NOx

Particulate Matter (PM) CEMS

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR

Assessment of Bias in Measurement of Mercury Emissions from Coal Fired Power Plants Comparison of Electronic CEMS and Sorbent Traps

FINAL TECHNICAL REPORT January 1, 2010, through March 31, 2011

Monitoring cement plant stack emissions using FTIR

Worldwide Pollution Control Association

Maintaining Continuous Emissions Monitoring Systems To Achieve High Reliability. a technical solution to meet every need

Sorbents Evaluation Testing Facilities. 95% removal efficiency or an emission standard of lbs/gw h by 2012, while

ECMPS Reporting Instructions Quality Assurance and Certification

PRODUCT CONFORMITY CERTIFICATE

Are You Really Ready for a RATA? August 5, 2015 CIBO Portland Maine Bob Davis Project Director TRC Environmental

PRODUCT CONFORMITY CERTIFICATE

John Downs Environmental Manager, B&W PGG, KVB-Enertec Products. January 29, 2015

2010 IEEE-IAS/PCA Environmental Workshop March 30, Robert McIlvaine McIlvaine Company

Air Mercury Speciation Accuracy and Calibration

XCEL ENERGY MERCURY MONITORING EXPERIENCES. David Hillesheim November 11, 2015

Title: Standard Operating Procedure for Measurement of CO in Ambient Air by Gas Filter Correlation (GFC)

Fully Extractive Vs. Dilution Extractive CEMS

Greenhouse Gas Regulation (new Federal)

Ambient Air Quality Monitoring

Building a Bigger, Better Zero Air Generator Certification Process

Process Optimization & Plant Safety

ECMPS Reporting Instructions Quality Assurance and Certification

Review of ConocoPhillips Alaska Inc. Continuous Emissions Monitoring Data from a 2014 Drill Rig Study at Kuparuk Drill Site 2N

BetaGuard PM Particulate Monitoring for Portland Cement MACT

An Overview of Mercury Monitoring Options

METHOD 30B DETERMINATION OF TOTAL VAPOR PHASE MERCURY EMISSIONS FROM COAL-FIRED COMBUSTION SOURCES USING CARBON SORBENT TRAPS

BetaGuard PM Measuring Particulate Continuously

Measurement and Reporting of Vapor Phase Mercury Emissions, Using a Sorbent Trap Monitoring System (DRAFT 9/25/08)

Calibration of Light Scatter PM-CEMs to Satisfy PS-11 on Wet Stacks in Coal Fired EGUs

Measurement of Corrosion Rate Associated with Halogen for Hg Oxidation

FINAL REPORT ENVIRONMENT CANADA

CEM. Continuous Emission Monitoring Systems NACT 221. Course Overview. National Air Compliance Training. CEM implementing regulations

PM Compliance Options for MACT and MATS Rules. Ed McCall PCME

ABB Measurement & Analytics Trace HCl measurements in coal-fired power plant emissions using Cavity Enhanced Laser Absorption Spectroscopy

BetaGuard PM Particulate Monitor Discussion. BetaGuard PM Background and Technical Information. BetaGuard PM CEM. MARAMA PM CEMS Webinar

Reducing Operating Costs and Risks of Hg Control with Novel Fuel Additives

A Brief Summary of Hg Control Test Results for Br Injection into Taconite Induration Furnaces

Mercury Vapour Monitoring with the MVI. By Peter Childs

Removal of Elemental Mercury from Flue Gas by V 2 O 5 /TiO 2 Catalysts Dispersed on Mesoporous Silica

MONITORING PROTOCOL IN SUPPORT OF THE CANADA-WIDE STANDARDS FOR MERCURY EMISSIONS FROM COAL-FIRED ELECTRIC POWER GENERATION PLANTS

SCR for NO x Control in Coal-fired Power Plants

DAILY LIFE of CEMS QA & PM

CEMS FOR COAL FIRED POWER STATIONS DEVICE CALIBRATION AND MAINTENANCE

Fpollutant-free zero air for analytical

Trace HCl measurements in coal-fired power plant emissions using Cavity Enhanced Laser Absorption Spectroscopy

STUDY OF MERCURY OXIDATION BY SCR CATALYST IN AN ENTRAINED-FLOW REACTOR UNDER SIMULATED PRB CONDITIONS

A global monitoring systems offering. A world of advantages. Thermo Scientific Continuous Emissions Monitoring Systems

RATA/Compliance Testing. Judith Aasland

PC MACT Updates. Cemtek Environmental Emissions Monitoring Seminar Costa Mesa, CA September 28, Vineet Masuraha Trinity Consultants Irvine, CA

High pressure conversion of NOx and Hg and their capture as aqueous condensates in a laboratory oxy-fuel compression system

Attachment 2. Quality Assurance and Operating Procedures for Sorbent Trap Monitoring Systems

A G. The Avogadro Group, LLC. Air Quality Consulting and Source Emissions Testing

ECMPS Reporting Instructions Emissions

CONTINUOUS EMISSION MONITORING SYSTEM. Copyright Adage Automation Pvt Limited

A Higher Standard of Monitoring Systems & Customer Service

Experiences in Long-Term Evaluation of Mercury Emission Monitoring Systems

Online Infrared Flue Gas Analyzer Gasboard 3000

Special Applications. Special Applications. ENVIRONMENTAL MONITORING. EPA Instrumental Test Methods as Defined by 40 CFR Part 60

UNEP Global Mercury Partnership Cement Industry Partnership Geneva Meeting June 18, 2013

Accurate determination of trace elements emissions using AFS. Dr Warren Corns. Coal Research Forum 2016 PSA. Slide 1

EMO August 1, Bobby I.T. Chen Client Program Manager

METHOD 3 - GAS ANALYSIS FOR THE DETERMINATION OF DRY MOLECULAR WEIGHT. NOTE: This method does not include all of the

Activated Carbon Injection for Mercury Control on Industrial Coal-Fired Boilers

Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions

Your Technology Resource

Comparison Continuous Emission Monitoring Techniques

Mercury Control in the Boiler

Chapter 10 Inspecting Combustion Sources

Inspecting Combustion Sources

WHITE PAPER: CONDUCTING A SUCCESSFUL MERCURY CONTROL DEMONSTRATION TEST AT A COAL- FIRED POWER BOILER INSTITUTE OF CLEAN AIR COMPANIES 2013

LARGE-SCALE MERCURY CONTROL TECHNOLOGY TESTING FOR LIGNITE-FIRED UTILITIES OXIDATION SYSTEMS FOR WET FGD

Replacement of Outlet Monitors for the Continuous Emission Monitoring System At the York County Resource Recovery Center. .

Worldwide Pollution Control Association

TUV Certified FTIR CEM and Ultra Low Level HCl CEM for Combustion Facilities

A Fixed Structure Approach to Mercury Control for Coal Fired Power Plants

Controlling Mercury Emissions from Coal-Fired Power Plants

Mercury Measurement and Control

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT COMPLIANCE DEPARTMENT COM 2025

CERTIFICATE of Product Conformity (QAL1 )

States Programs on Coal-Fired Utility Mercury Controls and Measurements; Status of Utility Mercury Control Technologies

ADVANCES IN BROMINE-BASED MERCURY EMISSION CONTROL AT DIFFERENT FRENCH WASTE INCINERATION PLANTS

The Proper Mechanism for Field Validating Moisture Analyzers. GE Measurement & Sensing GE Oil & Gas

Difficult CEMS Applications at Refineries & Chemical Plants

SPARK TM MOISTURE ANALYZER VALIDATION Performed in Conjunction with Air Products and Chemicals, Inc.

Local Impacts of Mercury from Coal-Fired Power Plants

Sampling Technology for Extractive CEMS & Maintenance Issues of CEMS Sanjeev Rai Perma Pure Aug 9, 2016

Mercury Sampling: A Comparison of Common Test Methods

SCR Control Strategy and CEMS for an Ultra-Low NO x Emitter

Transcription:

Hg CEMS Improvements and Updates Jeff Socha MARAMA Webinar November 21, 2013

Agenda Mercury CEMS overview Sample transport at lower temperatures Linearity across a wide concentration range QC checks with Hg Permeation Bromine injection and Low Level Measurements Probe Update 2

3 Hg CEMS Overview: Model 80i Hg Analyzer

Hg CEMS Overview: Model 81i Hg Generator Hg Vapor Generator Calibrates analyzer and probe Provides concentrations for Low/Mid/High (1 g/m 3 to 50 g/m 3 ) Uses a Peltier Cooler to control vapor pressure of Mercury source Uses mass flow controllers to vary output concentration NIST Traceable 4

Hg CEMS Overview: Zero Air / N 2 Generator Coalescing Filters Heatless Air Dryer Compressed Air In Surge Tank Chemical Scrubbers Nitrogen Generator 5

Hg CEMS Overview: Probe/Converter/Oxidizer 6 Speciation provides valuable information for Hg control

Sample Transport Sample lines on Thermo Scientific Mercury Freedom CEM Systems have been heated to 120 º C since the product was developed. Since conversion of oxidized Hg occurs in the probe, only elemental Hg is transported, not oxidized. Sample is transported at low pressure (nominally 60 mmhg) and sample is diluted ~ 40:1 Testing was needed to prove that a lowered line temperature did not effect performance 7

Midwest Plant: Dry, Horizontal Kiln w/o Inline Mill 8

RATA Results at Midwest Cement Plant 9 Using a cold spare line, not the heated sample line

Overview of the Test Group With the help of Spectrum Systems and various Utilities the following test group of 10 was selected; Qty. 5 CEMS at a Power Utility in the Southeast Qty. 3 CEMS at a Power Utility in the North Qty. 1 CEMS at a Power Utility in the West Qty. 1 CEMS at a Cement Plant in the Midwest Wet stacks, dry stacks in warm and cold climates, 100 to 500 ft lines 10

Results and Summary Operation of Thermo Scientific Mercury Freedom Sample line temperature at 50º C is proven acceptable based on this study. The lines were lowered to 50º C for the study, but it is recommend to operate at 70º C The sample line needs temperature control, not self limiting types These results are largely qualitative, but since the study began in 2011, many more operators have lowered their line temperatures and have not reported any adverse effects on accuracy (RATA) or precision (daily zero and span). 11

Hg Measurement over a Large Range Coal Fired Power Plant mercury emissions vary depending on what is happening in the process Plant On: X g/m3 Occasional/rare process upset: XX g/m3 Cement Kiln mercury emissions vary dramatically depending on what is happening in the process Mill On X g/m3 Mill Off XXX g/m3 Fortunately, Atomic Fluorescence is linear over a wide range of concentrations 12

Hg (ug/m3) Typical Variation at a Power Plant 12 10 8 6 4 2 0 7/20/2012 7/22/2012 7/24/2012 7/26/2012 7/28/2012 7/30/2012 13

Typical Variation at a US Cement Kiln Southeast Cement Plant - with inline mill 350 300 250 Hg µg/m 3 200 Raw mill off Raw mill on 150 100 Blowback 50 0 2/9/2010 7:12 2/9/2010 8:24 2/9/2010 9:36 2/9/2010 10:48 2/9/2010 12:00 2/9/2010 Time 13:12 2/9/2010 14:24 2/9/2010 15:36 2/9/2010 16:48 2/9/2010 18:00 14

Hg(mg/m3) Variation at a Cement Kiln outside the US Cement Kiln Outside of the US 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 5/16/11 8:24 5/16/11 9:36 5/16/11 10:48 5/16/11 12:00 5/16/11 13:12 5/16/11 14:24 5/16/11 15:36 5/16/11 16:48 5/16/11 18:00 Hg(o) Hg(t) 15

16 Linearity with a used stock Mercury system

Measured (μg/m3) Linearity with a used stock Mercury system System Span Linearity 250 200 y = 1.0473x - 0.1897 R 2 = 0.9999 150 100 50 0 Expected Conc Measured ug/m3 ug/m3 7.5 6.8 11.1 10.6 20.3 20.9 34.3 36.3 52.9 55.8 106.1 112.4 226.3 236.0 0 50 100 150 200 250 Generator Output (μg/m3) 17

QC Checks using a Permeation Source In order to comply with the 2009 Interim Elemental Mercury Gas Traceability Protocol, a Quarterly Audit is required: Option A: Field Reference Generator Option B: Permeation Tube Option C: Sorbent Tube Option D: Cylinder Gas 18

QC Checks using a Permeation Source Thermo has developed a Mercury Permeation Source (Model 84i) that integrates into existing and new Mercury CEMS in order to meet the requirements of Section 7 Done at the instrument, NOT through the system, to check the precision of the NIST traceable 81i mercury generator 19

20 Bromine Injection Testing

21 Mercury Freedom System Test Results

22 Mercury Freedom System Test Results

Bromine and Mercury Conclusion Hydrogen Bromide does react with elemental mercury, there were no signs of a measurement bias at 5 or 25 ppm HBr injection or Brominated AC with the TFS Mercury System Using the standard TFS oxidizer and converter, Mercuric Bromide behaves similarly to Mercuric Chloride, both in oxidation and reduction System Integrity Testing using Mercuric Bromide, show that the converter efficiency is >95% No measurement bias detected with the use of HBr or Brominated AC in the TFS system in this study 23

Probe Options We have partnered with M&C to provide another probe option Performance of the converter and oxidizer require testing on each unit to ensure quality and adherence to specifications 24

We would like to thank: Spectrum Systems (Sean Myrick and Reggie Davis) for providing a majority of the test information for the line temperature study. EERC (Dennis Laudal and Jeff Thompson) and EPRI (Chuck Dene) for the Bromine injection test data 25