4 5 6 8 18 13 10 15 SOFFIT OUTSIDE CORNER INSIDE CORNER 16 17 3 19 20 11 9 OPENING 12 END WALL 14 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY EH-01 INDEX EH-02 STANDARD PANEL OFFERING EH-03 SIDE LAP DETAILS EH-04 WALL SECTIONS EH-05 WALL SECTIONS EH-06 WALL SECTIONS EH-07 BASE DETAILS EH-08 PARAPET DETAIL EH-09 END LAP DETAIL EH-10 HEAD OPENING DETAILS EH-11 JAMB OPENING EH-12 SILL OPENING DETAILS EH-13 HEAD, JAMB, SILL INTERSECTION EH-14 END WALL DETAIL EH-15 SOFFIT DETAILS EH-16 OUTSIDE CORNER DETAILS EH-17 INSIDE CORNER DETAILS EH-18 4 CORNER INTERSECTION EH-19 PENETRATION DETAILS (1 of 2) EH-20 PENETRATION DETAILS (2 of 2) NOTE: DETAILS ARE FOR PROMOTIONAL USE ONLY. FOR COMPLETE DETAILS, REFER TO CENTRIA'S WEB SITE AT www.centria.com EH-01
1 1 2 " [38] 3" [76] 4" [102] 3'-0" [914] NOMINAL 7.2" [186] 3'-0" [914] NOMINAL 9" [229] 34 2/3"[881] NOMINAL 37 1/3"[948] NOMINAL 3'-0" [914] NOMINAL 7.2" [183] 3'-0" [914] NOMINAL 1'-0" [305] 2'-0"[610] NOMINAL 1'-0" [305] STYLE-RIB MR3-36 SUPER-RIB 1 1 2 " [38] 1 1 2 " [38] 1 1 2 " [38] 3 4 " [19] 2 16 11 " [68] 2 16 11 " [68] BR5-36 TR4-36 ECONOLAP 3/4" ECONOLAP 1/2" STANDARD PANEL OFFERING EH-02
36"[914] ('A') 36"[914] ('A') 24"[610] ('A') 36"[914] 36"[914] 24"[610] STYLE-RIB MR3-36 SUPER-RIB ('A') = FIELD INSTALLED NON-CURING BUTYL SEALANT 36"[914] ('A') 36"[914] ('A') 34 2 3 "[881] ('A') 37 3 1 "[948] ('A') 36"[914] 36"[914] 34 3 2 "[881] 37 3 1 "[948] BR5-36 TR4-36 ECONOLAP 3/4" ECONOLAP 1/2" EH-03
DRAINED & VENTED CAVITY FEILD APPLIED NON- CURING BUTYL INTERIOR SHEATHING STUD INSULATION EXPOSED FASTENER PANEL CONTINUOUS VERTICAL PLASTIC SHIMS EXTERIOR SHEATHING WEATHER-RESISTIVE BARRIER AND AIR BARRIER PANELS ON PROTECTED EXTERIOR SHEATHING WITH CAVITY INSULATION VAPOR RETARDER LOCATION THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT IS A REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS. THEREFORE THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION. DRAINED & VENTED CAVITY EXPOSED FASTENER PANEL VERTICAL 3/4" [19] DEEP 16 GA. SUBGIRT FIELD APPLIED NON- CURING BUTYL VERTICAL SUPPORTS WEATHER-RESISTIVE BARRIER HORIZONTAL LINER PANEL FACTORY APPLIED LINER SEALANT FIELD-APPLIED (1.65 PCF) INSULATION IN LINER CAVITY AIR BARRIER (LINER PANEL) PANELS WITH INSULATION IN HORIZONTAL LINER EH-04
DRAINED & VENTED CAVITY EXPOSED FASTENER PANEL 3/4" SUBFRAMING AND AIR CAVITY METALWRAP INSULATED BACK-UP PANEL FIELD APPLIED NON- CURING BUTYL METALWRAP INSULATED BACK-UP PANEL "A" "A" METALWRAP PANEL CLIP AT EACH PANEL SIDE JOINT (36" O.C.) VERTICALLY AND INTO EACH FRAMING MEMBER (16" TO 24" O.C.) HORIZONTALLY SUBFRAMING FASTENER ANCHORED INTO CENTER OF METALWRAP CLIP SECTION A-A EXPOSED FASTENER PANEL PANELS WITH METALWRAP INSULATED BACK-UP PANEL DRAINED & VENTED CAVITY EXPOSED FASTENER PANEL FIELD APPLIED NON-CURING BUTYL VERTICAL 3/4" [19] DEEP 16 GA. SUBGIRT CON'T. HORIZONTAL ZEE 16 [1.52] GA. MIN. (SPACING TO BE DETERMINED BY CLADDING ENGINEER) INTERIOR SHEATHING STUD EXTERIOR SHEATHING WEATHER-RESISTIVE BARRIER AND AIR BARRIER INSULATION SUITABLE FOR MOISTURE EXPOSURE PANELS WITH INSULATION OUTBOARD OF STUD CAVITY VAPOR RETARDER LOCATION THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT IS A REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS. THEREFORE THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION. EH-05 Aug. 11
(*) CONTINUOUS VERTICAL ZEE SHAPED SUBGIRT (SHIM AS REQUIRED) (*) SUBGIRTS SHALL BE 1.) 16 GA. MINIMUM. 2.) 3/4" [19] MINIMUM DEPTH. 3.) 1/4" [6] DEEPER THAN INSULATION THICKNESS. 4.) SPACED AT 24" [610] OR 48"O.C. [1219] BASED ON DESIGN LOADS AND INSULATION SIZE. FIELD APPLIED NON-CURING BUTYL MASONRY INSULATION SUITABLE FOR MOISTURE EXPOSURE AIR BARRIER & WATER RESISTANT COATING OR MEMBRANE EXPOSED FASTENER PANEL DRAINED & VENTED CAVITY MASONRY FASTENER PANELS WITH INSULATION OVER MASONRY WALL VAPOR RETARDER LOCATION THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT IS A REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS. THEREFORE THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION. EXPOSED FASTENER PANEL VERTICAL SUPPORTS FINISH IS REQUIRED ON BOTH SIDES OF THE PANEL SINCE BOTH SIDES ARE EXPOSED TO THE WEATHER PANELS USED AS A SCREEN WALL EH-06 Aug. 11
1 8 "GAP GAP SELF ADHERING TAPE EXTERIOR SHEATHING WEATHER-RESISTIVE BARRIER AND AIR BARRIER STUDS POLYURETHANE SEALANT BASE at SLAB (Low Cell) (EFHZ-2001A) OPTIONAL COVER POP RIVET OPTIONAL DETAIL FLASH SUPPORT CLIP 3" LONG @ STUDS 1 8 " [3] GAP SELF ADHERING TAPE EXTERIOR SHEATHING WEATHER-RESISTIVE BARRIER AND AIR BARRIER STUDS BASE at SLAB (High Cell) (EFHZ-2001) EH-07
PARAPET (EFHZ-2012) EH-08
WEATHER-RESISTIVE BARRIER AND AIR BARRIER EXTERIOR SHEATHING STUDS 2" [51] NON-CURING BUTYL 4" [102] MIN. LAP END LAP (EFHZ-2005) STUDS WEATHER-RESISTIVE BARRIER & AIR BARRIER EXTERIOR SHEATHING MIN. 18 GAGE FLASH CONTINUOUS SHIMS CONTINUOUS SHIM 1 2 " [13] 1 4 " END LAP (EFHZ-2005C) EH-09
EXTERIOR SHEATHING SELF ADHERING TAPE WEATHER-RESISTIVE BARRIER AND AIR BARRIER STUDS HEAD OPENING (Low Cell) (EFHZ-2000A) 1 8 " [3] GAP 1 8 " [3] GAP NBC EXTERIOR SHEATHING SELF ADHERING TAPE FLASH SUPPORT CLIP 3" LONG @ STUDS WEATHER-RESISTIVE BARRIER AND AIR BARRIER STUDS NBC OPTIONAL COVER POP RIVET HEAD OPENING (High Cell) (EFHZ-2000) 1 8 " [3] GAP OPTIONAL DETAIL EH-10
STUDS EXTERIOR SHEATHING WEATHER-RESISTIVE BARRIER AND AIR BARRIER METAL AND COMPOSITION CLOSURES 2 1 2 "MIN. 1 2 "CLR. JAMB OPENING (EFHZ-2003) EH-11
NBC SHIM FOR VENTING STUDS WEATHER-RESISTIVE BARRIER AND AIR BARRIER EXTERIOR SHEATHING SILL OPENING (HIGH CELL) (EFHZ-2006) NBC SHIM FOR VENTING STUDS WEATHER-RESISTIVE BARRIER AND AIR BARRIER EXTERIOR SHEATHING SILL OPENING (LOW CELL) (EFHZ-2006A) EH-12
INTERSECTION OF HEAD, JAMB & SILL FLASH (EFHZ-2016) EH-13
STUDS SELF ADHERING TAPE EXTERIOR SHEATHING WEATHER-RESISTIVE BARRIER AND AIR BARRIER METAL AND COMPOSITION CLOSURES 2 1 2 "MIN. BACKER ROD & SEALANT END WALL (EFHZ-2008) EH-14
WEATHER-RESISTIVE BARRIER AND AIR BARRIER SELF ADHERING TAPE NON-CURING BUTYL METAL AND COMPOSITION CLOSURES STUDS EXTERIOR SHEATHING 1 8 " [3] GAP MIN. SOFFIT - FRONT (EFHZ-2013A) SUPPORT EXTERIOR SHEATHING WEATHER-RESISTIVE BARRIER AND AIR BARRIER METAL AND COMPOSITION CLOSURES POP RIVET SHIM FOR VENTING 12"[305] O/C OPTIONAL CLEAT ATTACHMENT SOFFIT - BACK (EFHZ-2014A) EH-15
EXTERIOR SHEATHING OUTSIDE CORNER WITH (EFHZ-2009) WEATHER-RESISTIVE BARRIER AND AIR BARRIER METAL AND COMPOSITION CLOSURES STUDS OUTSIDE CORNER MICROSEAM (EFHZ-2017) EH-16
STUDS METAL AND COMPOSITION CLOSURES INSIDE CORNER WITH (EFHZ-2010) EXTERIOR SHEATHING WEATHER-RESISTIVE BARRIER AND AIR BARRIER INSIDE CORNER MICROSEAM (EFHZ-2018) EH-17
TYPICAL HORIZONTAL PANEL ERECTION PROCEDURE (REFER TO DIAGRAM "A" BELOW FOR ERECTTION SEQUENCE) NOTE:WHEN LAPPING PANEL "F" OVER PANEL "A" THE UPPER LEFT HAND CORNER OF PANEL "F" MUST SLIP UNDER PANEL "B". THIS PROCEDURE SHALL BE TYPICAL FOR ALL SUBSEQUENT PANELS. (THIS PROCEDURE PREVENTS MATERIAL BUILD-UP AT FOUR CORNER CONDITIONS) E D C B A J I H G F DIAGRAM "A" (BUILDING ELEVATION) FOUR CORNER INTERSECTION (EFHZ-2019) EH-18
PENETRATION DETAIL (EFHZ-2015) NOTE: REF. PAGE EH-20 FOR SECTS. A-A & B-B EH-19 Aug. 11
PANEL FLAT ANGLE FLASH NON-CURING BUTYL SECTION A-A (EFHZ-2015A) STUDS METAL AND COMPOSITION CLOSURES NON-CURING BUTYL POLYURETHANE SEALANT SECTION B-B (EFHZ-2015B) PENETRATION DETAIL EH-20 Aug. 11