SURFACE APPLIED TACTILE / DETECTABLE WARNING SURFACE TILES (Rectangular and Radius Tiles)

Similar documents
STAGGERED DOME SURFACE APPLIED TACTILE / DETECTABLE WARNING SURFACE TILES (For Transit Use)

DIRECTIONAL BAR TILE / WAY-FINDING SURFACE TILES (Wet-Set and Surface Applied)

CAST IN PLACE TACTILE / DETECTABLE WARNING SURFACE TILES

HEAVY DUTY CAST IN PLACE REPLACEABLE TACTILE / DETECTABLE WARNING SURFACE TILES

1.02 DESCRIPTION A. This Section specifies furnishing and installing Surface Applied Detectable/Tactile Warning Surface Tiles where indicated.

Surface Mount Tactile

Proudly Made in the U.S.A.

Yours truly, John Heffner Access Products Inc. National Sales Manager

HERCULITE REPLACEABLE CAST IN PLACE DETECTABLE/TACTILE WARNING SURFACE TILE

Proudly Made in the U.S.A. 5-Year warranty. Radius TacTile. cast-in-place Replaceable (wet-set) or surface mount.

SECTION DETECTABLE GUIDE TACTILES

SURFACE APPLIED 3" X 48" ADVANCED WARNING STRIP SECTION 09614

Proudly Made in the U.S.A. 5-Year Warranty. Wayfinding Products

SURFACE APPLIED DETECTABLE/TACTILE WARNING SURFACES. Please feel free to print this PDF form. The document is below. Please scroll down.

MODULAR PAVER DETECTABLE/TACTILE WARNING SURFACES

ADA APPROVED SURFACE APPLIED DETECTABLE WARNING SYSTEM

SECTION DETECTABLE/TACTILE WARNING SURFACES

Proudly Made in the U.S.A. 5-Year Warranty. Wayfinding Products

Yours truly, John Heffner Vice President Access Products Inc.

Proudly Made in the U.S.A.

Decorative Fiberglass Reinforced Wall Panels

CAST IN PLACE DETECTABLE/TACTILE WARNING SURFACES SECTION DETECTABLE/TACTILE WARNING SURFACES

SECTION PAVER TILE

Nudo Guide Specification 03/01/2016 FiberScore FRP Wall Panels SECTION FIBERSCORE FIBERGLASS REINFORCED WALL PANELS

SECTION STRUCTURAL REINFORCED POLYMER COMPOSITE PEDESTRIAN BRIDGE DECK

PRODUCT GUIDE SPECIFICATION

Union County Vocational - Technical Schools Scotch Plains, New Jersey

DUR-A-FLEX, Inc. Page 1 of 5

SECTION UNIT PAVERS

CON-DEK ICC-ES ESR-2097 SYSTEM

1/16 Single Broadcast Polymer Flooring System

ENGINEERING SPECIFICATION FIBERGRATE 62% OPEN AREA/ADA COMPLIANT MOLDED GRATING. January 5,

ACOUSTICAL WALL TREATMENT SECTION 09840

B. Related Sections: 1. Division 07 Section "Joint Sealants" for sealing of expansion, contraction, control, and isolation joints in tile surfaces.

RediMat. surface applied. Features. Physical Characteristics. Installation. Colors. Sizes. the original flexible surface applied mat

Pacific Polymers Elasto-Deck 5000X2 Guide Specification

CONCRETE TILE PAVERS

Florock Seamless Flooring Systems

Product Guide Specification

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

CONSULT COLDSPRING FOR ASSISTANCE IN EDITING THIS SPECIFICATION GUIDE FOR SPECIFIC APPLICATIONS.

Pacific Polymers Elasto-Deck 5000MR Guide Specification

Powerdek Fleck. SECTION Resilient Athletic Flooring

Desco Granite Flooring Specifications

Florock Seamless Flooring Systems

ROOF BALLAST MATERIALS ARCHITECTURAL CONCRETE PAVING SLABS SRS LEVELING BLOCK SYSTEM INSTALLATION PART GENERAL 1.

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

A. This section includes pre-finished Higuera Hardwoods bamboo flooring and accessories for floors and stairs.

SECTION PRECAST CONCRETE PAVERS AND PEDESTAL LOK DOWN SYSTEM

SECTION ARCHITECTURAL FIBERGLASS

SECTION RESILIENT SHEET FLOORING

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

SECTION ARCHITECTURAL FIBERGLASS

A. Prepare formwork shop drawings using qualified professional engineer. Include detail of fabrication, assembly, and support of formwork.

MRXL4 CR6 Surface Requirements: XNS, NS, M, S; Special Requirements: NO PART 1 : GENERAL

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

Broadcast Parking Garage System

SECTION A. American Society for Testing and Materials (ASTM):

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

80201R StoColor Acryl Flat Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

SECURE LOCK INTERLOCKING TILES Product Guide Specification

SECTION RESINOUS FLOORING PLEXIQUARTZ BROADCAST SKID-RESISTANT QUARTZ SYSTEM

A. This Section includes resinous flooring systems with epoxy body coat(s).

Florock Seamless Flooring Systems

PRODUCT SPECIFICATIONS

Florock Seamless Flooring Systems

Section RESILIENT TILE FLOORING INCLUDING ECONATURALS RUBBER FLOOR TILE

System Specification CEM-DYE 250 SYSTEM Division 9 Finishes Section Staining and Transparent Finish

A. This Section includes traffic coatings for the following applications:

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings.

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION ORNAMENTAL ALUMINUM RAILING

Florock Seamless Flooring Systems

Dist. by: BEST MATERIALS Ph:

Florock Seamless Flooring Systems

SUBSTITUTION REQUEST (After the Bidding/Negotiating Phase)

ENGINEERING SPECIFICATION PULTRUDED HIGH LOAD CAPACITY (HI) SAFE-T-SPAN FIBERGLASS GRATING. January 24,

Superior Aluminum Guide Specification 10/4/2016 Non-Welded Aluminum Pipe Railing

Florock Seamless Flooring Systems

ALGRIP Slip-Resistant Metal Floor Plates Exceptionally durable slip-resistant flooring solutions for high traffic areas

Corium Brick Rainscreen System Specifications

DUR-A-FLEX, Inc. Page 1 of 6

HAWORTH PORCELAIN FLOORING SYSTEM CSI Specifications 03/29/2017. A. Concrete work and concrete floor sealer is specified in Section

Product Guide Specification

1/8 DECORATIVE BROADCAST FLOORING SYSTEM

Desco Quartz Cremona Specifications

RULON ACOUSTICAL CEILING SYSTEM ALURATONE 100 ARCHITECTURAL SPECIFICATIONS

Narrow Modular Pavers (NMP) for Sand-Set Installations

SECTION [ ] MANUFACTURED METAL BOLLARDS

First Class Building Products, Inc.

ENGINEERING SPECIFICATION FIBERTRED MOLDED STAIR TREADS SECTION 06610

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Section COATING RESTORATION

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

SECTION TILING

Florock Seamless Flooring Systems

SECTION TERRAZZO FLOOR TILE

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

Transcription:

PART 1 GENERAL SURFACE APPLIED TACTILE / DETECTABLE WARNING SURFACE TILES (Rectangular and Radius Tiles) 1.01 DESCRIPTION A. This Section includes Specifications for furnishing and installing Surface Applied Tactile / Detectable Warning Surface Tiles (SA) in an inline truncated dome pattern on all curb ramps and walking surfaces at the locations and to the dimensions shown on the Drawings, in accordance with the Contract Documents and as directed by the Engineer. (Surface Applied Tactile is also known as Surface Mount Tactile Warning Tiles or Retrofit Tactile Warning Tiles) 1.02 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Special Conditions and Division 1 Specifications, apply to this Section. B. Americans with Disabilities Act (ADA) Title 49 CFR Transportation, Part 37.9 Standards for Accessible Transportation Facilities, Appendix A, Section 4.29.2 Detectable Warnings on Walking Surfaces. FHA Memo (5-06-02) titled Truncated Domes. Federal Register Volume 71, No. 209, 49 CFR Part 37 (10-30-06), ADA Standards for Transportation Facilities (11-29- 06, DOT): Sections 406, 705, and 810. ADA Standards for Accessible Design 2010 (9/05/11, DOJ), ADAAG: Sections 705 and 810. Proposed Accessibility Guidelines for Pedestrian Facilities in the Public Rights of Way (7/23/11, Access Board), PROWAG: Sections R208, R304, R305, R308, and R309. C. American Society for Testing and Materials (ASTM) Test Methods B117, C501, C1028, D543, D570, D638, D695, D790, G151, G155, and E84. D. American Association of State Highway and Transportation Officials (AASHTO): Test Method AASHTO-H20. E. California Code of Regulations (CCR 2007) Title 24 Part 1 Articles 2, 3 and 4, and Part 2 Section 205 definition of Detectable Warning, Section 1127B.5 for Curb Ramps, and Section 1133B.8.5 for Detectable Warnings at Hazardous Vehicle Areas. California Department of Transportation Detectable Warning Surface Authorized Material List. Division of the State Architect IR 11B-3 (1/26/05) and IR 11B-4 (1/01/11). IR 11B-4 (1/01/11) removed the requirement for a staggered pattern and now calls for the square grid (in-line) pattern. 1.03 SUBMITTALS Surface Applied Tactile 1

A. Product Data: Submit manufacturer s literature describing products, installation procedures and maintenance instructions. B. Samples for Verification Purposes: Submit two (2) Tactile Warning Surface samples minimum 8 x 8 of the kind proposed for use. Samples shall be properly labeled and shall contain the following information: Name of Project, Submitted by, Date of Submittal, Manufacturer s Name, and Catalog Number. C. Shop Drawings: Submit Standard Manufacturer Shop Drawings showing all pertinent characteristics of the Surface Applied Tactile Warning Tile (SA) including profile, sound on cane contact amplification feature, fastener locations and installation methods. D. Material Test Reports: Submit current test reports from qualified, accredited independent testing laboratory in accordance with ASTM guidelines and indicating that materials proposed for use are in compliance with specification requirements and meet the properties indicated. All test reports submitted shall be representative of the Surface Applied Tactile Warning Tile (SA) delivered to the Project. E. Maintenance Instructions: Submit copies of manufacturer s specified maintenance practices for each type of Tactile Warning Surface Tile and accessory. 1.04 QUALITY ASSURANCE A. Provide composite Surface Applied Tactile Warning Tiles (SA) as produced by a single manufacturer with a minimum of five years experience in manufacturing Surface Applied Tactile Warning Tiles (SA). B. Installer s Qualifications: Engage an experienced installer certified in writing by the Tactile Warning Surface manufacturer, who has successfully completed Tactile Warning Surface installations similar in material, design, and extent to that indicated for the Contract. C. Surface Applied Tactile Warning Tiles (SA) must be compliant with ADAAG, PROWAG, and CATitle 24 requirements. Division of the State Architect IR 11B-3 (1/26/05) and IR 11B-4 (1/01/11). IR 11B-4 (1/01/11) removed the requirement for a staggered pattern and now calls for the square grid (in-line) pattern. D. Surface Applied Tactile Warning Tiles (SA) shall meet or exceed the following test criteria using the most current test methods: 1. Water Absorption: Not to exceed 0.20%, when tested in accordance with ASTM- D570. 2. Slip Resistance: 0.80 minimum combined wet/dry static coefficient of friction when tested in accordance with ASTM C1028. Surface Applied Tactile 2

3. Compressive Strength: 25,000 psi minimum, when tested in accordance with ASTM D695. 4. Tensile Strength: 10,000 psi minimum, when tested in accordance with ASTM D638. 5. Flexural Strength: 25,000 psi minimum, when tested in accordance with ASTM D790. 6. Chemical Stain Resistance: No reaction to 1% hydrochloric acid, motor oil, calcium chloride, gum, soap solution, bleach, and antifreeze, when tested in accordance with ASTM D543. 7. Abrasion Resistance: 300 minimum, when tested in accordance with ASTM C501. 8. Flame Spread: 25 maximum, when tested in accordance with ASTM E84. 9. Accelerated Weathering of Tactile Warning Surface when tested by ASTM-G155 or ASTM G151 shall exhibit the following result: E<5.0 at 2,000 hours minimum exposure. 10. Adhesion Test for Tactile Warning Surface Tile: No delamination of Tactile Warning Surface Tile. Peel Test board failure in temperature range of 20-180 degrees, when tested in accordance with ASTM C903. 11. Salt and Spray Performance of Tactile Warning Surface: No deterioration or other defects after 200 hours of exposure, when tested in accordance with ASTM-B117. 1.05 DELIVERY, STORAGE AND HANDLING A. Surface Applied Tactile Warning Tiles (SA) shall be suitably packaged or crated to prevent damage in shipment or handling. Finished surfaces shall be protected by sturdy wrappings. B. Storage Facility 1. Store SA Tiles in an area that is within an acceptable temperature range (40-90 degrees). In particular, protect sealants from freezing. 2. Maintain Storage Facility in a clean dry condition to prevent contamination or damage to SA Tiles and incidentals. 1.06 GUARANTEE A. SA Tiles shall be guaranteed in writing for a period of five (5) years from date of Contract s final completion. The guarantee includes manufacturing defects, breakage, and deformation. PART 2 PRODUCTS 2.01 MATERIALS A. Composition: SA Tiles shall be manufactured using a matte finish exterior grade homogeneous (uniform color throughout thickness of product) glass and carbon Surface Applied Tactile 3

reinforced polyester based Sheet Molding Compound (SMC) composite material. Truncated domes must contain fiberglass reinforcement within the truncated dome for superior structural integrity and impact resistance. A matte finish will be required on the Tactile Warning Surface for superior slip resistance performance superior to that offered by a gloss finish. Use of Tactile Warning Surface Products employing coatings or featuring layers of material with differing composition, performance, or color properties is expressly prohibited under this Section. B. Color: Color shall be homogeneous throughout SA Tile. 1. Federal Yellow (Y) per Federal Standard 595B Table IV, Color No. 33538. 2. Brick Red (R) per Federal Standard 595B Table IV, Color No. 20109. 3. Clay Red (CR) per Federal Standard 595B Table IV, Color No. 22144. 4. Safety Red (SR) per Federal Standard 595B, Table IV, Color No. 31350. 5. Black (B) per Federal Standard 595B Table IV, Color No. 37038. 6. Dark Gray (G) per Federal Standard 595B Table IV, Color No. 36118. 7. Safety Blue (B) per Federal Standard 595B Table IV, Color No. 15187. 8. White (W) per Federal Standard 595B Table IV, Color No 37925. 9. Seattle Yellow (SY) per Federal Standard 595B Table IV, Color No. 23594. 10. Houston Beige (Pantone #7529C). C. Domes: Square grid pattern of raised truncated domes of 0.2 nominal height, base diameter of 0.9 and top diameter of 0.45. The Federal Code of Regulations permits a truncated dome spacing range of 1.6-2.4. For superior wheelchair, walker and shopping cart mobility, the preferred truncated dome spacing shall have a center-tocenter (horizontally and vertically) spacing of 2.35, measured between the most adjacent domes on square grid. D. Configuration: SA Tile sizes shall be as indicated on the Contract Drawings. The field area shall consist of a non-slip textured surface with a minimum static coefficient of friction of 0.80, wet and dry. At a minimum, the thickness of the body of SA Tile shall measure 0.1875 (nominal). The SA Tile thickness shall not exceed ½ maximum when measured from the curb ramp surface to the top of the truncated dome. 1. The field area shall consist of a non-slip textured surface with a minimum static coefficient of friction of 0.80, wet and dry. E. In compliance with the Proposed Accessibility Guidelines for Pedestrian Facilities in the Public Rights of Way (7/23/11, Access Board, PROWAG ) Section R302.7.2 and California Code of Regulations (CCR 2007) Section 1127B.5.5 and Section 1133B.8.5, the Composite Tactile Warning Surface Tiles shall have a perimeter beveled edge with a maximum slope of 1:2 in order to minimize the potential for a pedestrian tripping. F. Radius SA Tile: Surface Applied Tactile 4

1. Radius SA Tile measures 24 x 33.25 and features reverse score lines on each 24 dimension for a 10, 15, and 20 radius condition. The Radius SA Tile out of the box measures 11-6 radius. 2. Truncated domes feature proper dome alignment for a radius application. Radius SA Tile shall be cut to the appropriate configuration using the reverse score lines as a guide. G. Follow Tactile Warning Surface Manufacturer s installation procedures. 1. ADA Solutions, Inc. Installation Procedure ( http://adatile.com/pdf/ada-surfacemount- Installation.pdf) H. Dimensions: SA Tiles shall be held within the following dimensions and tolerances: Specifiers Note: Edit section below by selecting desired length and width. Delete nonrelevant dimensions. 1. Length and Width: Rectangular SA Tile: 1.67 Dome Spacing: [24 x36 ] [24 x48 ] [24 x60 ] [36 x48 ] [36 x60 ] 2.35 Dome Spacing: [24 x36 ] [24 x48 ] [24 x60 ] [36 x48 ] [36 x60 ] Radius SA Tile: 1.6-2.4 Dome Spacing [24 x33.25 ] I. Fasteners: The Tactile Warning Surface Tile shall have minimum twelve (2 x3 Tactile Warning Surface Tile) to twenty-four (3 x5 Tactile Warning Surface Tile) countersunk fastening holes. Color matched, stainless steel 304, flat head drive anchor: ¼ diameter x 1 1/2 long. J. Adhesive: 1. Polyether Structural Adhesive/Sealant by Chem Link (M-1) 2. Urethane Elastomeric Adhesive by Bostik (Hydroment Ultra-Set Advanced or Durabond D-818) 3. Approved equal. K. Sealants: 1. Single Component Urethane Sealant: i. Sources: BASF NP1 by BASF Building Systems or Sikaflex 1A by Sika Corp. ii. Colors: Black, Limestone, Redwood Tan 2. Polyether Structural Adhesive/Sealant by Chem Link (M-1) i. Colors: Black, Gray, Limestone, White 3. Approved Equal Surface Applied Tactile 5

L. Cleaning materials used on site shall have code acceptable low VOC solvent content and low flammability. M. The Specifications of the concrete, sealants and related materials shall be in accordance with the Contract Documents and the guidelines set by their respective manufacturers. 2.02 MANUFACTURERS A. Available manufacturers, subject to compliance with these Specifications include, but are not limited to, the following: 2.03 EQUIPMENT 1. ADA Solutions Inc. of Chelmsford, MA (Phone: 800-372-0519, Fax: 978-262-9125, Web Site: www.adatile.com, E: info@adatile.com ), or approved equal. 2. Requests for Approved Equal Status must be submitted and approved by the Owner during the Bid Phase of the Project. A. Contractor shall provide all tools, equipment and services required for satisfactory installation per the Tactile Warning Surface Product manufacturer s instruction. PART 3 EXECUTION 3.01 PREPARATION A. Transmit submittals and deliverables required by this Section. B. Furnish products as indicated. C. Substrate Condition: Ensure substrate is in suitable condition, and in compliance with the Tactile Warning Surface manufacturer recommendations, to receive work of this Section. Prior to construction, refer any and all discrepancies to the Engineer for further action. 3.02 INSTALLATION A. Contractor will not be allowed to install Tactile Warning Surface Tiles until all submittals have been reviewed and approved by the Engineer. B. SA Tile shall be installed per manufacturer s instructions. C. To the maximum extent possible, the SA Tiles shall be oriented such that the rows of inline truncated domes are parallel with the direction of the ramp. When multiple SA Tiles regardless of size are used, the truncated domes shall be aligned between the tactile warning surface tiles and throughout the entire tactile warning surface installation. Surface Applied Tactile 6

D. In accordance with the Proposed Accessibility Guidelines for Pedestrian Facilities in the Public Rights of Way (7/23/11, Access Board): Sections 304 + 305), Tactile Warning Surface Tile shall be located relative to the curb line as shown within Sections 304+305 of the Guidelines. E. Cutting of SA Tiles may be required to accommodate specific site conditions. All possible attempts shall be made to minimize cutting of the SA Tiles. Minimum acceptable width of the cut SA Tile shall be 9. F. Environmental Conditions: Air and substrate temperatures must exceed 40 degrees for at least 8 daytime hours for a sound and proper installation. A weed torch may be used to boost the substrate temperature to expedite cure of adhesives and sealants. G. Immediately prior to installing the SA Tiles, the concrete surfaces must be inspected to ensure that they are clean, dry, free of voids, curing compounds, projections, loose material, dust, oil, grease, sealers and determined to be structurally sound with a minimum four (4) day concrete cure period (unless otherwise directed by the SA Tile manufacturer) and that the surface is flat. As necessary, substrate may be mechanically cleaned with a diamond cup grinder or shot blaster to remove any dirt or foreign material although a broom or leaf blower is usually adequate for cleaning of the substrate. H. Apply adhesive on the backside of the SA Tiles following the perimeter border and internal cross pattern established by the SA Tile manufacturer. Sufficient adhesive must be placed on the prescribed areas to have full coverage across the 2 inch width of the adhesive locator. 1. For certain applications, generally encountered in the retail environment, the Tactile Warning Surface manufacturer may direct that full coverage adhesive be applied so as to optimize the tactile warning surface Tile s performance and load bearing capacity. I. Set the SA Tile(s) true and square to the curb ramp areas as detailed in the Drawings. Allow 1/8 separation between successive SA Tiles for expansion/contraction. J. Drill holes true and straight to a depth of 2 1/2 by 1/4 using the recommended bit. As necessary, additional countersunk holes may be added to the SA Tile by using a 5 point ½ (82 degree) countersink to create the necessary holes. K. Mechanically fasten SA Tile to the concrete substrate using a 32oz. to 48oz. hammer to set the composite sleeve anchors. Ensure that the fastener has been set to full depth, straight and true. Care should be taken when setting the fastener to avoid any advertent blows with the hammer to the SA Tile. L. Following the installation of the SA Tile, the sealant system should be applied to the perimeter edge. Follow the Tactile Warning Surface manufacturer s recommendations when applying the sealant in a cove type profile to blend and seal the SA Tile edge to the adjoining surfaces. Surface Applied Tactile 7

M. Do not allow foot traffic on installed SA Tile until the perimeter edge sealant has cured sufficiently to avoid tracking. If the SA Tile must be placed into immediate pedestrian service, apply baby powder to the sealant to minimize the possibility of tracking while the sealant cures. Foot imprints may appear in the fully cured sealant application N. On Continuous Runs: The Installer shall leave a 3/16 nominal gap between successive Tactile Warning Surface Tiles. As part of the concrete finishing operation, the Installer shall apply 1/8 - ¼ edge treatment around the perimeter of the Tactile Warning Surface Tiles to facilitate future replacement of the Tactile Warning Surface Tile. A Urethane Sealant such as Sikaflex 1a or BASF NP1 shall be applied to the edge treatment for a watertight Tactile Warning Surface Tile installation. 3.03 CLEANING AND PROTECTING A. Protect SA Tiles against damage during construction period to comply with SA Tiles manufacturer s Specifications. B. As necessary, while the Project remains under construction, protect SA Tiles against damage from rolling loads following installation by covering with plywood or hardwood. C. If requested by the Project Manager, clean SA Tiles not more than four (4) days prior to date scheduled for inspection intended to establish date of substantial completion in each area of project. Clean SA Tile by method specified by Tactile Warning Surface Products manufacturer. ** U. S. Patent # 7,779,581 + # 8,028,491 + One or More U.S. Patents Pending END OF SECTION Updated 5-10-12 Surface Applied Tactile 8