Agenda Item No. AGENDA ITEM BRIEFING

Similar documents
Agenda Item No. 8 AGENDA ITEM BRIEFING. Submitted by: Gregory R. Anderson, Chief Financial Officer and Treasurer

SOUTH DAKOTA BOARD OF REGENTS. Committee on Budget and Finance ******************************************************************************

FACILITY DESIGN PLAN FOR PHYSICAL EDUCATION COMPLEX FROST ARENA HVAC REPLACEMENT SOUTH DAKOTA STATE UNIVERSITY. May 17, 2013

TO MEMBERS OF THE FINANCE AND CAPITAL STRATEGIES COMMITTEE: ACTION ITEM CONSENT

DIVISION MEDIUM VOLTAGE VAULT DESIGN Contents MEDIUM VOLTAGE VAULT DESIGN... 2 DIVISION LIST OF FIGURES...

DIVISION MEDIUM VOLTAGE VAULT DESIGN Contents

FACILITY DESIGN PLAN FOR HARDING HALL RENOVATION AND ADDITION SOUTH DAKOTA STATE UNIVERSITY DATE: March 29, 2017

SOUTH DAKOTA BOARD OF REGENTS. Budget and Finance ******************************************************************************

Element Z General Design Requirements Existing Facilities Information

SOUTH DAKOTA BOARD OF REGENTS. Budget and Finance ******************************************************************************

SOUTH DAKOTA BOARD OF REGENTS. Budget and Finance ******************************************************************************

Project Delivery Evaluation

SOUTH DAKOTA BOARD OF REGENTS. Committee on Budget and Finance ******************************************************************************

New York State Contract Reporter

Submitted to. Texas A&M University - Kingsville The Texas A&M University System. Submitted by. Yeqiao Zhu John Bryant Dan Turner David Claridge

TO MEMBERS OF THE COMMITTEE ON GROUNDS AND BUILDINGS: ACTION ITEM

BUCKNELL UNIVERSITY PROCEDURES FOR RENOVATIONS AND NEW CONSTRUCTION

How to Prepare Your LSE Report

TO MEMBERS OF THE COMMITTEE ON GROUNDS AND BUILDINGS: ACTION ITEM

Current as of 11/10/08 1 of 5

Work Order (Bid Form) Upper East Tennessee Human Development Agency

Programmatic Need Building improvements will support the Fine Arts Music Department Programs.

PENNSAFE BUILDING INSPECTION SERVICES LLC NEW COMMERCIAL BUILDING UCC PLAN REVIEW HANDOUT AND CHECKLIST

FACILITY DESIGN PLAN FOR INDOOR PRACTICE AND HUMAN PERFORMANCE FACILITY SOUTH DAKOTA STATE UNIVERSITY

TO MEMBERS OF THE FINANCE AND CAPITAL STRATEGIES COMMITTEE: ACTION ITEM CONSENT

Energy Compliance Information

Energy Compliance Information

Thule Prototype BIM Manual for Dormitories. February 5, 2010

AN INNOVATIVE DEDICATED OUTDOOR AIR APPLICATION FOR A GOVERNMENT OFFICE TOWER. MICHAEL HALLENBECK, PE, CEM Southland Industries

1. When using the REScheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Executive Order RP 49 Quarterly Energy Report for Texas A&M University September 2012

TRIAD ENGINEERING CONSULTANTS, INC.

The Board of Finance of Baltimore City Department of Finance Bureau of Treasury Management

SOUTH DAKOTA BOARD OF REGENTS. Budget and Finance Consent ******************************************************************************

Air-Water Systems. Chilled Ceilings and Beams TROX USA. Principle of Operation. Radiant Effect on Occupants. Early 1980 s. Chilled Ceiling Panels

MINUTES OF THE MEETING SDSU CENTRAL HEATING PLANT BOILER REPLACEMENT AND PLANT UPGRADES June 17, 2011

/ Policy Number: Policy Name: Capital Planning and Development Processes Definitions

Florida Army National Guard Construction Facilities Management Office. Scope of Work:

MINIMUM PLAN INFORMATION REQUIRED FOR A BUILDING PERMIT

SOUTH DAKOTA BOARD OF REGENTS. Budget and Finance ******************************************************************************

CITY OF ROHNERT PARK CITY COUNCIL AGENDA REPORT

IECC 2006 with Hawaii Amendments

Energy Management Report

Retail Effects of ANSI/ASHRAE/IES Standard

Major Project Request Biennium

DESIGN DEVELOPMENT REVIEW PACKAGE CHECKLIST

1 data PIC location (with 2 ports) typically asf for multiple staff members

SCHOOL MITIGATION DESIGN CONSIDERATIONS

Compliance Certificate

Florida Army National Guard Construction Facilities Management Office. Scope of Work:

Communications Page 1 of 9

City High Middle School pre-design recommendations. March 29, 2017

PHYSICAL FACILITIES Consultant s Handbook Division 27 COMMUNICATIONS 0000 COMMUNICATIONS

Status of Fire Station Upgrade. December 8, 2016

GAUTENG DEPARTMENT OF INFRASTRUCTURE DEVELOPMENT

REScheck Software Version Compliance Certificate

Characteristics of Energy Consumption by building type of a U.S. Navy Installation in Hot and Humid Climate

CONCURRENT ADVERTISEMENT FOR SUBCONTRACTOR PREQUALIFICATION AND BIDS

Chair of FLMC and CFO Approvals

SUNY Hospitals & A Healthier New York. Capital Briefing March 1, 2013

2012 Fiscal Impact International Mechanical Code

COMMERCIAL TENANT IMPROVEMENT PERMIT APPLICATION

VILLAGE OF BOSTON HEIGHTS 45 E. Boston Mills Road Hudson, OH REGULAR COUNCIL MEETING OF July 14, :00 PM

A/E Design Deliverable Checklist

EXHIBIT "A" RESPONSIBILITIES AND SERVICES OF ARCHITECT/ENGINEER. A. Basic Services...A-1. B. Pre-Design and Start-Up Services...

Permit Application Commercial / Industrial / Multi-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

NOTICE OF ADDENDUM TO RFQ DOCUMENTS ADDENDUM NO. 01 August 29, 2018 ENGINEERING SERVICES FOR VARIOUS KERN COMMUNITY COLLEGE DISTRICT PROJECTS

RESOLUTION WHEREAS,

See attached answers to questions and requests for clarification received.

ARTICLE 1. FIRE LIMITS AND BUILDING REGULATIONS

TEXAS A&M ENGINEERING

Borough President and City Council Capital Funding Requests FY 2008

BID PROPOSAL FORM C.I.P. NO PROJECT: VETERANS PARK SHOOTING RANGE LEAD ABATEMENT/DEMO

Full-Scope Commissioning for High-Quality Buildings

Building Permit Application

BUILDING CODES & DESIGN CRITERIA

SOUTH DAKOTA BOARD OF REGENTS. Budget and Finance ******************************************************************************

Permit Application Commercial / Industrial / Mutli-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE (Form #2)

Safety Update Crossing study is in final review stages. Facilities Update Construction Progress

Texas State University System Telephonic Called Board of Regents Meeting

CODE COMPLIANCE PLAN REVIEW PROCEDURES

CONSTRUCTION REQUIREMENTS

ORDINANCE NO. XXXX BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF LAWRENCE, KANSAS:

ASHRAE 62.2: What s New in 2016

CITY OF OAK CREEK SINGLE FAMILY & TWO-FAMILY CONSTRUCTION/PERMIT REQUIREMENTS

Office of Superintendent of Schools April 1, 2019 Board Meeting of April 17, 2019

How LEED & The Retro-Commissioning Credits Produce Energy Savings. James Vallort Vice President Environmental Systems Design, Inc.

VILLAGE OF VERNON HILLS REQUEST FOR PROPOSAL FOR CONSTRUCTION MANAGER AT RISK SERVICES. Part I: Proposal Information

DESIGN CHECKLIST PROJECT NAME DISCIPLINE DATE TYPE REVIEW REVIEWER DRAWINGS REVIEWED

SECTION PAYMENT PROCEDURES

Compliance Certificate

APPLICATION FOR FINISHED BASEMENT PERMIT

ANNUAL DEVELOPMENT ACTIVITY AND DISCLOSURE REPORT $4,115,000 CITY OF WHEELING, WEST VIRGINIA STONE BUILDING RENOVATION PROJECT SERIES 2005 A BONDS

City of High Point Airport Overlay District Noise Level Reduction Design Standards

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016

BUILDING CODE BULLETIN

CHARLES COUNTY GOVERNMENT ITB NO WAKEFIELD PUMPING STATION UPGRADE

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

Coach House: Hunziker Hall:

Transcription:

Agenda Item No. AGENDA ITEM BRIEFING Submitted by: Michael K. Young, President Texas A&M University Subject: Approval of the Project Scope and Budget, Appropriation for Construction Services, and Approval for Construction for the HVAC Replacement at Clements Hall Project, Texas A&M University, College Station, Texas (SSC Project No. 2016-01444) Background and Prior Actions: The HVAC Replacement at Clements Hall Project was included as an approved project on the FY 2017 FY 2021 A&M System Capital Plan approved by the Board at the September 2016 meeting. Proposed Board Action: (1) Approve the project scope and budget. (2) Appropriate $7,123,200 for construction services and related project costs and revert previous appropriations to the source account. (3) Approve construction of the HVAC Replacement at Clements Hall Project at Texas A&M University (Texas A&M). Funding/Budget Amount: Funding Source Budget Amount Average Estimated Annual Debt Service Revenue Financing System Debt Proceeds $7,123,200 $536,345 Debt Service Source Housing Revenue Total Project Funds $7,123,200 Project Justification: Originally constructed in 1981, Clements Hall is a four-story concrete structure consisting of 128 modular rooms/spaces (the majority being dorm rooms). Total square footage is approximately 62,156 gross square feet (GSF). Each room is conditioned by an individual Fan Coil Unit (FCU) served by a four-pipe Chilled Water (CHW) and Heating Water (HW) piping distribution system. Each room has a pneumatic thermostat and fan speed control switch (Hi/Med/Lo/Off). Corridors are conditioned by floor-mounted FCUs as well as two Outside Air Units (OAU) units located on the roof with a duct chase located adjacent to the stairwells on both ends of each floor. Page 1 of 2

Agenda Item No. Agenda Item Briefing Outside Air (OA) is served to the corridor and introduced to each room via door undercut using bathroom exhaust to draw. OA short circuits from the corridor to the bathroom without mixing in the room space. Stairwells are not currently conditioned. OA intake louvers are located in the areaway near grade and ducted in crawl space to ventilate crawlspace via two fans. The Heating Ventilation Air Conditioning (HVAC) system has reached the end of its useful life and is in need of replacement. Existing electrical switchgear is also beyond its useful life and will be replaced on this project. Gear is fusible type with spare parts not available for use on this project. Scope: This project will replace all FCUs with new four-pipe FCUs with HW coils in the re-heat position. Each room will have a thermostat and humidistat to implement a humidity control strategy at the room level. A fan speed controller will be provided in each room to allow for student control of the FCU. Corridor floor-mounted FCUs will be replaced. Conditioned OA will be provided via a new roof-mounted air handler with integral Energy Recovery Unit (ERU). Existing exhaust fans will be removed. New exhaust ductwork will be manifolded on the roof and routed to the ERU to capture energy currently being exhausted. New OA and exhaust duct risers will be installed to introduce conditioned fresh air into each room. A new FCU will be provided to serve the stairwells. General construction shall consist of the removal and replacement of existing ceilings to facilitate mechanical work. A bid alternate for one new roof hatch for safer roof access as well as an alternate for two new floor hatches to be located in each stairwell will be issued to provide access for replacement of and repair of crawl space exhaust fans. Construction on this project is scheduled to start in December 2017 with substantial completion scheduled for July 2018. The total project budget is $7,123,200. Other Major Fiscal Impacts: None. Page 2 of 2

Members, Board of Regents The Texas A&M University System Agenda Item No. TEXAS A&M UNIVERSITY Office of the President June 30, 2017 Subject: Approval of the Project Scope and Budget, Appropriation for Construction Services, and Approval for Construction for the HVAC Replacement at Clements Hall Project, Texas A&M University, College Station, Texas (SSC Project No. 2016-01444) I recommend adoption of the following minute order: The project scope along with a project budget of $7,123,200 for the HVAC Replacement at Clements Hall Project is approved. The amount of $7,123,200 is appropriated from Account No. 01-083540, Revenue Financing System Debt Proceeds (Housing Revenue), for construction services and related project costs. The amount of $672,000 is reverted to Account No. 02-030062 Residence Life. The HVAC Replacement at Clements Hall Project, Texas A&M University, College Station, Texas, is approved for construction. The Board of Regents of The Texas A&M University System (Board) reasonably expects to incur debt in one or more obligations for this project, and all or a portion of the proceeds received from the sale of such obligations is reasonably expected to be used to reimburse the account(s) for amounts previously appropriated and/or expended from such account(s). As required by Section 5(a) of the Master Resolution of the Revenue Financing System, the Board hereby determines that it will have sufficient funds to meet the financial obligations of The Texas A&M University System, including sufficient Pledged Revenues to satisfy the Annual Debt Service Requirements of the Revenue Financing System and to meet all financial obligations of the Board relating to the Revenue Financing System and that Page 1 of 2

Agenda Item No. June 30, 2017 the Participants, on whose behalf the debt is issued, possess the financial capacity to satisfy their Direct Obligations. Respectfully submitted, Michael K. Young, President Texas A&M University Approval Recommended: Approved for Legal Sufficiency: John Sharp Chancellor Ray Bonilla General Counsel Billy Hamilton Executive Vice Chancellor and Chief Financial Officer Page 2 of 2

HVAC REPLACEMENT AT CLEMENTS HALL TEXAS A&M UNIVERSITY SSC PROJECT NO. 2016-01444 PROJECT BUDGET 1. Amount Available for Construction Contract...... $5,740,800 2. Owner s Contingency... 574,080 3. Architectural/Engineering Fees... 459,840 4. SSC Project Management Fees... 204,998 5. SSC/Physical Plant Services... 15,500 6. Energy System Testing & Balancing... 43,056 7. Other Project Costs... 84,926 8. TOTAL ESTIMATED COST OF PROJECT... $7,123,200 Page 1 of 4

HVAC REPLACEMENT AT CLEMENTS HALL TEXAS A&M UNIVERSITY SSC PROJECT NO. 2016-01444 PROJECT SCHEDULE 1. BOR Approval to Include in Capital Plan... September 1, 2016 2. Issue A/E RFQ... March 14, 2017 3. Receive A/E RFQ Responses... April 4, 2017 4. Interview A/E Shortlist... April 5, 2017 5. Design Kick-Off Meeting... April 2017 6. Execute AE Agreement... May 2017 7. Complete Schematic Design... June 2017 8. Complete Design Development... July 2017 9. Complete Construction Documents... July 2017 10. Advertise for Competitive Sealed Proposals (CSP)... July 2017 11. Receive CSPs... August 2017 12. CSP Evaluation... August 2017 13. BOR Approval for Construction... August 23,2017 14. Execute CSP Agreement... August 2017 15. Begin Construction... December 2017 16. Substantial Completion... July 31, 2018 17. Owner Occupancy... August 2018 Page 2 of 4

TEXAS A&M UNIVERSITY REVENUE FINANCING SYSTEM HVAC Replacement Clements Hall Housing Revenue Outstanding Principal Interest Coverage Dates Principal Amount Amount Annual Total 1.15x BONDS 7,195,000.00 YEAR 1 7,055,000.00 140,000.00 395,725.00 535,725.00 616,083.75 YEAR 2 6,905,000.00 150,000.00 388,025.00 538,025.00 618,728.75 YEAR 3 6,750,000.00 155,000.00 379,775.00 534,775.00 614,991.25 YEAR 4 6,585,000.00 165,000.00 371,250.00 536,250.00 616,687.50 YEAR 5 6,410,000.00 175,000.00 362,175.00 537,175.00 617,751.25 YEAR 6 6,225,000.00 185,000.00 352,550.00 537,550.00 618,182.50 YEAR 7 6,030,000.00 195,000.00 342,375.00 537,375.00 617,981.25 YEAR 8 5,825,000.00 205,000.00 331,650.00 536,650.00 617,147.50 YEAR 9 5,610,000.00 215,000.00 320,375.00 535,375.00 615,681.25 YEAR 10 5,380,000.00 230,000.00 308,550.00 538,550.00 619,332.50 YEAR 11 5,140,000.00 240,000.00 295,900.00 535,900.00 616,285.00 YEAR 12 4,885,000.00 255,000.00 282,700.00 537,700.00 618,355.00 YEAR 13 4,620,000.00 265,000.00 268,675.00 533,675.00 613,726.25 YEAR 14 4,340,000.00 280,000.00 254,100.00 534,100.00 614,215.00 YEAR 15 4,045,000.00 295,000.00 238,700.00 533,700.00 613,755.00 YEAR 16 3,730,000.00 315,000.00 222,475.00 537,475.00 618,096.25 YEAR 17 3,400,000.00 330,000.00 205,150.00 535,150.00 615,422.50 YEAR 18 3,050,000.00 350,000.00 187,000.00 537,000.00 617,550.00 YEAR 19 2,680,000.00 370,000.00 167,750.00 537,750.00 618,412.50 YEAR 20 2,290,000.00 390,000.00 147,400.00 537,400.00 618,010.00 YEAR 21 1,880,000.00 410,000.00 125,950.00 535,950.00 616,342.50 YEAR 22 1,445,000.00 435,000.00 103,400.00 538,400.00 619,160.00 YEAR 23 990,000.00 455,000.00 79,475.00 534,475.00 614,646.25 YEAR 24 510,000.00 480,000.00 54,450.00 534,450.00 614,617.50 YEAR 25-510,000.00 28,050.00 538,050.00 618,757.50 $ 7,195,000.00 $ 6,213,625.00 $ 13,408,625.00 $ 15,419,918.75 Estimated issuance costs and rounding of $71,800 are included in this schedule. Long-term rates are assumed to be 5.50%. Rates are subject to market change. Prepared by the Office of the Treasurer - Treasury Services 6/6/17 Rates are subject to market change. Amounts are preliminary estimates that will be revised at the time bonds are issued. Page 3 of 4

REVISED HVAC Replacement at Clements Hall Texas A&M University SSC Project No. 2016-01444 Page 4 of 4