Making the difference with Live Image Guidance Dose management in Allura systems

Similar documents
Image guided therapy. Azurion 7. With Azurion, performance and superior care become one

Image guided therapy. Azurion 3. With Azurion, performance and superior care become one

Image guided therapy. Azurion 7. With Azurion, performance and superior care become one

Making the difference

Radiation Exposure During Endovascular Procedures: Methods to Protect Patients, Physicians and OR Personnel

Making the difference

Making the difference with Live Image Guidance

Radiation Protection in Fluoroscopy

What s the Issue? Radiation Dose in the OR. Exposure to OR Personnel. Effects of Proper Collimation. Image-guided procedures are increasingly complex

DoseWise Portal. Take control of dose management. across your organization

There are three general methods for reducing one's personal radiation exposure. The application of each when working around fluoroscopy units will be

Function of this control

Take control of dose management

Adapting to the way you work

Making the difference where it really matters

Making the difference with Live Image Guidance

Minnesota Rules, Chapter 4732 X-ray Revision

Disclaimer and Notices.

Dose management at Ziehm Imaging for 2D imaging

Workflow optimization in the hybrid OR. Arjan Hoksbergen, Vascular Surgeon Rutger Lely, Interventional Radiologist

Xper Information Management. Connected. cardiology across your enterprise with the interventional module of IntelliSpace Cardiovascular

Unlimited potential at your fingertips

Comprehensive Dose Management for Improved Patient Care.

Multifunctional remote control X-ray system. Adapting to the way you work

FLUOROSCOPIC SAFETY AND PATIENT AND OPERATOR RADIATION DOSE REDUCTION: CREATING A FOCUSED FLUOROSCOPIC CURRICULUM FOR RADIOLOGY RESIDENTS

Disclaimer and Notices.

2018/7/31. Primary Objective

New Joint Commission Requirements for Fluoroscopy Services

Dose Reduction during EVAR in Hybrid Room. Multicentric Study

Optimizing the Use of Pulsed Fluoroscopy to Reduce Radiation Exposure to Children

Protecting Patients 3/5/2014. Educating and Engaging your Staff in Radiation Safety

Making the difference

Optima IGS 330 Versatility within your reach. gehealthcare.com

Interventional Radiology

Improving protocols and procedures for strengthened radiation protection in interventional procedures

With Philips Azurion,

MANAGING PATIENT DOSE IN FLUOROSCOPIC PROCEDURES

Fluoroscopy units come in many different physical configurations but all consist of the main components shown in this slide.

Healthcare. Philips DoseWise Portal. Radiation exposure management software

Patient doses in lower limb angiography in a recently installed flat detector x-ray system

High performance comes easily

Maximize access, minimize costs

Fluoroscopic Radiation Safety

Ceiling Mount, Floor Mount & Biplane. Hybrid Lab. *The system pictured is the INFX-8000C

Workflow innovation in the Azurion Hybrid OR

Image guided therapy. Neuro suite. Azurion. Neuro suite. Neuro decisions are based on what you see, so see more

FLUOROSCOPIC PATIENT & OPERATOR RISK REDUCTION

Table of Contents. Adaptive Diagnostics...7 Integrated Dose Reduction Streamlined Workflow Clinical Images... 26

Making the difference with Philips Live Image Guidance. Hybrid Suite solutions

Methods for measuring fluoroscopic skin dose

White Paper. Dose Tracking System. Patient Skin Dose Estimates in Real Time

Easy that excels Discovery RF180

A Paradigm Shift in Patient Dose Monitoring

Patient radiation dose and image quality optimization in CT. Optimiser la dose patient et la qualité image en scanner

Do More with Less Dose Optimised Imaging Protocols for Endovascular Procedures

How to Optimize Radiation Protection During Complex Peripheral

Radiation protection for theatre staff (refer guidelines) DISTANCE, TIME, SHIELDING principle should be applied

Radiation Physics and Safety Considerations in the EP Lab

1. Executive Summary

Interventional Fluoroscopy

GENESIS Edition. Transforming CT

Radiation Dose Terms Made Simple v1

GE Healthcare. Brivo DR-F. Simply digital.

Low Dose, Lightning Speed, Latest Applications

The role of Diagnostic Reference Levels in Optimization

COMPREHENSIVE FAMILY OF INTERVENTIONAL SYSTEMS

Dose at an interventional reference point: Comparison between displayed values of X-ray units and actual measured values

Precisely Your View. Uroview FD. Digital Imaging Suite for Urology. GE Healthcare. Authorized Distributor. GE Healthcare

Luminos Fusion accurate, available, amazing Answers for Life.

Quality ID #145: Radiology: Exposure Dose or Time Reported for Procedures Using Fluoroscopy National Quality Strategy Domain: Patient Safety

Leading Canadian Pediatric Hospital Continues to Drive Dose Down for Sick Children

Surgical Mobile C-Arm Imaging System OPESCOPE ACTENO Free and easy positioning achieves optimal performance to meet the demands of the operation room

7/30/2018. Paid Speaker, Bayer. Radiology Cardiology Interventional Endoscopy Pain Medicine Speech Language Pathology Surgery List is longer than this

A dosimetric trial for the clinical follow-up of potential skin injuries on patients undergoing interventional cardiology procedures

Imaging Systems. Gene Saragnese, CEO Healthcare Imaging Systems

GE Healthcare. OEC 9800 Plus. A Classic Choice

GE Healthcare. OEC 9800 Plus. A Classic Choice

More flexibility More performance Less dose

INVALUABLE VERSATILITY. GO DIGITAL. YOUR WAY. DRX-Evolution

Department of Radio Diagnosis

مباحث :IAEA Training Material on Radiation Protection in Cardiology. List of Topics & Objectives١.doc

OEC Elite CFD. This is just INGENIOUS. GE Healthcare. What s New

Portable and Mobile X-ray Units

2017 Global General Radiography Product Line Strategy Leadership Award

Gafchromic XR-RV2 radiochromic films dosimetry in interventional radiology

First Experiences with the Ziehm Vision FD Mobile C-Arm with Flat-Panel Detector

Fluoroscopy Credentialing Training Program for Non-Radiologist Physicians. Department of Radiology

Intracranial stent visualization for image guided interventions and therapy

NATIONWIDE EVALUATION OF X-RAY TRENDS (NEXT)

GENESIS Edition Transforming CT

Power of BRANSIST safire in Neuroendovascular Therapy


Equipment Quality Control for Fluoroscopy February 22, Imaging Physics CancerCare Manitoba

Clinical Applications. ImagingRite. Neuro Intervention. 1 ImagingRite

Radiation protection in the cath lab and interventional radiology: practical hints and tricks

The Insightful Design SIREMOBIL Iso-C

Vision & Mission. healthcare solution group

Clinical Applications. ImagingRite. Interventional Radiology

7/28/2017. Michael Speidel. University of Wisconsin - Madison

New Product Innovation Leadership

Transcription:

DoseWise Allura Making the difference with Live Image Guidance Dose management in Allura systems

The importance of radiation dose management The harmful effects of X-rays on human tissues had already become apparent just months after their discovery by Wilhem Röntgen in 1895 1. The main concern for patients is usually associated with the risk of skin injuries 2, which can occur when radiation dose thresholds are exceeded. And the risks are not only limited to the patient, with scatter radiation having been proven to be harmful to the medical staff present during procedures. At Philips, we have established ourselves as an industry leader in the area of techniques and technologies that provide clinically relevant image quality during each interventional application while reducing dose with our DoseWise Allura solutions. 2 DoseWise Allura

Protecting your patients and your people As a result of advances in technology, the growth in the number and complexity of interventional procedures has been significant 3, increasing the risk of patients and staff exceeding dose thresholds. Therefore, efforts to minimize radiation dose are crucial and are today a priority for the healthcare industry. Successful management of patient radiation dose can only be achieved by optimization of medical imaging technology combined with proper control of the imaging equipment by the operator 4. In this respect, it is the goal of equipment manufacturers like Philips to provide medical professionals with the technology and features that facilitate the application of the ALARA (As Low As Reasonably Achievable) principle to reduce the radiation dose delivered to both patients and staff. Philips rigorously applies the ALARA principle to its technology, delivering benefits to the health and safety of physicians, patients, and healthcare staff. DoseWise Allura is integrated across our Allura FD interventional X-ray portfolio. It combines a variety of dose management strategies and techniques that help you to deliver the optimal balance between dose level and image quality. DoseWise Allura 3

Philips, leading the way in dose management Breakthrough solutions Interventional X-ray 1896 1952 1979 1981 1988 1992 1995 1996 Introduction of the first medical X-ray tube by CHF Müller, Philips First commercial X-ray image intensifier Digital Video Image Processor Digital Substraction Angiography (DSA) MRC X-ray tube and Spectra Beam copper filtration system Rotational Angiography Grid Switched Fluoroscopy 1998 2001 2003 2005 2010 2012 2013 2014 Introduction of collimation on Last Image Hold Introduction 3D-RA Introduction Flat panel detector with Xres3 imaging processing Introduction of X-ray Personalized (Xper) & Dose display Introduction XperCT and StentBoost DoseAware - real time dose feedback for physicians AlluraClarity X-ray system with ClarityIQ technology Introduction DoseAware Xtend Introduction DoseWise portal * * Product under development, not yet for sale. For decades Philips interventional X-ray systems have been at the forefront of the technological advances that continue to improve patient care and safety. An early example is Philips invention of dose saving grid switch technology that has been a feature of our interventional products since the 1980 s making Philips a true pioneer in the field of dose reduction and image quality. Optimizing image quality whilst controlling X-ray dose Every intervention requires a different balance between Image Quality and X-ray dose, based on procedure type, patient size, projection angle and physician preferences. Furthermore, during an intervention, different tasks may require different image qualities and therefore different dose levels as illustrated in the figure below; Finding the right balance between image quality and X-ray dose can be a challenging task, involving numerous parameters such as frame rate, copper filtration, collimation, shutter positions, image processing settings and many others. It is for these reasons that each Allura FD interventional X-ray system is delivered (as standard) with dozens of clinically relevant presets, each containing hundreds of fine-tuned parameters that can be further adjusted by Philips specialists to meet the specific needs of a physician. Philips DoseWise Allura Personalized X-ray Patient dose Allura Xper Our dose reduction solutions specific to Philips Allura systems are known collectively as DoseWise Allura; a unique combination of techniques, programs and practices, built into our Allura FD interventional X-ray systems that provide clinically relevant image quality during each interventional application, while reducing dose. Localization Characterization Required image quality Different tasks require different image quality resulting in different patient dose levels DoseWise Allura offers your patients and staff significant dose-savings using a unique combination of components. At Philips, we divide factors that influence dose and image quality in three main categories: Smart Technology More Control Better Awareness 4 DoseWise Allura

Our innovations to support you in reducing dose DoseWise Allura s exceptional image quality and dose management capabilities are made possible by a variety of proprietary technologies developed by Philips. These intrinsic features are those system components that form the foundation of exceptional imaging, such as the generator, MRC X-ray tube, dynamic flat detector, and real-time image processing. Detector X-ray conversion efficiency up 25% compared to previous generation GridSwitch Up to 80% reduction compared to non-gridswitch fluoroscopy Smart Technology More Control SpectraBeam Pre-filtration Up to 50% reduction compared to no filtration Advanced image processing Boost image quality Better Awareness DoseWise Allura s SpectraBeam filtration enables you to achieve enhanced image quality at the same patient dose, or reduced patient dose at the same image quality, with no relation between detector dose and patient dose. ma DoseWise Allura s X-ray generation GridSwitch principle can help to reduce emitted dose up to 80%. Conventional pulsed fluoroscopy Detector Dose IQ+ IQ+ Ramping Imaging pulse Trailing Time Patient Dose 1000 500 ma Grid Switch X-ray tube power Conventional X-ray tube 1000 2000 MRC X-ray tube 0.4mm Cu Imaging pulse Time Switching Tube Current Radiation by High Tension Cables DoseWise Allura 5

Ensuring your workflow is dose optimized DoseWise Allura offers a variety of unique features which allow you to tailor your system by image quality and dose to meet your specific requirements. These include our clinically optimized X-ray protocols, low-dose protocols, fluoro choices, fluoro store, and collimation on Last Image Hold. Optimized X-ray protocols Up to 80% reduction by selecting optimized protocols for the anatomy (e.g. Cardio vs EP) Smart Technology More Control Collimation, shutter & wedge on LIH Reduced exposed patient area to the region of interest FluoroChoices & FluoroStore Up to 80% reduction by selecting the lowest fluoro dose Better Awareness Eco Dose Enables you to lower the image quality to the necessary minimum DoseWise Allura gives you increased control and position of both shutters and wedges on the last clinical image hold (LIH) enabling improved dose-reduction. Optimized X-ray protocols such as our Xper settings help to personalize your system to better reflect your needs. 6 DoseWise Allura

Assisting you in creating an increased awareness of dose DoseWise Allura assists the user in creating dose awareness via in-room actual zone area AK display, structured patient dose reporting, and real-time staff dose display. DoseAware for staff (optional) Proven to improve workflow habits of healthcare staff Smart Technology More Control Structured patient dose reporting Enhanced patient dose management In-room patient dose indication In room awareness of patient dose AK Better Awareness DoseAware Xtend provides you with detailed, realtime procedure based feedback for your staff. You can now display system data information directly on FlexVision and it provides you with data of scattered dose in relation to the dose emitted. AK Operators can view a fuel gauge to measure accumulated skin dose. This includes predicted skin dose by body zone and estimated timings until applicable limits are reached. DoseWise Allura 7

The Philips commitment to dose management DoseWise is an expression of our longstanding commitment to reduce dose in your patients and staff, while maintaining the acquisition of clinically optimized images. Supported by our proprietary smart technology and awareness programs, we ensure that your needs are central, giving you more control and better awareness at all times during X-ray procedures. In conclusion Why choose DoseWise Allura? At Philips we are continuously looking for innovative ways to help you better protect your patients and your people. For further materials, information, and news on how we are helping healthcare organizations like yours to better manage radiation dose, visit our dedicated webpage. www.philips.com/dosewise-allura DoseWise Allura is standard on all Philips Allura interventional X-ray systems SpectraBeam provides unique beam filtration over the entire patient thickness range and in all projections Provides you with a powerful X-ray tube with Philips patented GridSwitch technology Our unique Xper technology enables the flexibility to tune image quality and dose to your individual requirements Includes integrated patient and staff real-time dose display on FlexVision with the optional DoseAware Xtend 1 Sansare, K, et al. Early victims of X-rays: a tribute and current perception. Dentomaxillofacial Radiology. 2011;40:123-5. 2 Balter S, et al. Fluoroscopically guided interventional procedures: a review of radiation effects on patients skin and hair. Radiology. 2010;254:326-41. 3 Klein, LW, Donald L Milller, Stephen Balter, et al Occupational health hazards in the interventional laboratory: time for a safer environment Radiology 2009 : 250(2):538-544 4 Strauss KJ, Kaste SC. The ALARA (as low as reasonably achievable) concept in pediatric interventional and fluoroscopic imaging: striving to keep radiation doses as low as possible during fluoroscopy of pediatric patients a white paper executive summary. Pediatr Radiol. 2006;36 (Suppl 2):110 112. This material is not intended for distribution in the United States. 2015 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice. Trademarks are the property of Koninklijke Philips N.V. (Royal Philips) or their respective owners. www.philips.com/dosewise-allura Printed in the Netherlands 4522 991 10061 * April 2015