Take control of dose management

Similar documents
DoseWise Portal. Take control of dose management. across your organization

Healthcare. Philips DoseWise Portal. Radiation exposure management software

RADIATION DOSE MONITOR

RADIATION DOSE MONITOR. The DACS for Building a Low-Dose Culture

Contrast Dose Management. For CT and MR

Making the difference where it really matters

COCIR CT MANUFACTURERS VOLUNTARY COMMITMENT REGARDING CT DOSE OPTIMIZATION Annual Report

Stay Ahead of the Curve in Radiation Reduction Standards

The Consistent Quality of Connected Radiology

CARESTREAM RIS/PACS SuperPACS Architecture. A Changing Landscape

Medical Radiation Reporting: A Manufacturer s Perspective

Making the difference

Adapting to the way you work

COCIR CT Manufacturers Voluntary Commitment Regarding CT Dose 2014 Annual Report

Making the difference

Multifunctional remote control X-ray system. Adapting to the way you work

Making the difference with Live Image Guidance Dose management in Allura systems

High performance comes easily

HEALTHCARE. Taking workflow where you want it to go.

What good would having all your images on a single platform do? Agfa HealthCare. Enterprise Imaging

Stand Alone Viewers A COMPLETE DIAGNOSTIC VIEWER WITH CONSOLIDATED WORKLIST DESIGNED TO OPTIMIZE REPORTING TIME

WORKLIST. Optimizing your workflow

teamplay data sheet valid from March 2017 teamplay data sheet siemens.com/teamplay

Image guided therapy. Azurion 7. With Azurion, performance and superior care become one

Image guided therapy. Azurion 3. With Azurion, performance and superior care become one

Image guided therapy. Azurion 7. With Azurion, performance and superior care become one

siemens.com/teamplay teamplay data sheet

Pathology Solution IVD US. Philips IntelliSite HER2/neu IHC Digital Manual Read

Mobile Radiography Radiology Information System by AMT/EMD

Site Customization Screen

The New World of Unified Image Management

IHE. Integration Statement. DigitalDiagnost Koninklijke Philips Electronics N.V. All rights are reserved.

Clinical depth anywhere, anytime

IHE Integration Statement

Unlimited potential at your fingertips

The Leading Low-code Application Platform For Modern Work Management

ViewPoint 6 Clarify your View

IHE Integration Statement

Xper Information Management. Connected. cardiology across your enterprise with the interventional module of IntelliSpace Cardiovascular

A continuous quality improvement process to reduce excessive CT radiation dose events across a large, multiinstitutional

Joint Commission Medical Imaging Requirements. Laura Gruber, MBA, RT(R), RDMS, RVT Sr. Director Department of Medical Imaging SPR Annual Meeting

PRESS RELEASE. At Arab Health 2015, Agfa HealthCare showcases how its solutions meet the evolving needs of the Future of Radiology

for exceptional care

Actionable intelligence to guide your decisions

IHE Integration Statement EPIQ 7 Release 1.1.x.x EPIQ 5 Release 1.0.x.x October 14, 2013

Integrating the Imaging Workflow By Konica Minolta

SOLUTIONS Express Enterprise SP Enterprise XP Integral Breast Workspace. better images mean better results

PACS A WEB-BASED APPLICATION DESIGNED TO AUTOMATE YOUR WORKFLOW

FutuRIS System. Pavel Zaytsev CEO

Prioritization of IHE Radiology Profiles. Herman Oosterwijk, President, OTech, Inc.

synedra Digitization in Healthcare Facilities

RIS / PACS A WEB-BASED APPLICATION DESIGNED TO AUTOMATE YOUR WORKFLOW

Future bound. Philips Ingenuity Core

Radiation Dose Index Monitoring (RDIM)

Workflow. Quality Assurance. Workflow. Hologic 3D Tomosynthesis Connectivity Information OBJECTIVES 3/31/2015

Making the difference with Live Image Guidance

Relied on by the world s. radiology. departments. IMPAX 6: Digital Image and Information Management

IHE for emerging market Learning from integration experiences

Selenia Digital Breast Imaging Saving Time, Saving Lives.

optimizes cardiology workflow

Workflow Manager Whitepaper: WORKFLOW GAPS IN ENTERPRISE IMAGING By: Val Kapitula RT(R), PMP, CIIP

Technical Information SupplyCare Enterprise SCE30B

Introduction. FDA Approval. Breast Tomosynthesis From the Ground Up

BACKING THE RIGHT HORSE

IHE. Integration Statement. Eleva Workspot Koninklijke Philips Electronics N.V. All rights are reserved.

Start Simple, Partner with Perspective Radimetrics Select Package is a simple yet scalable solution to

UNDERSTANDING THE NEED FOR A HELP DESK SOLUTION. How to select the right help desk solution for your organization

Diagnostic ECG. ST80i stress-testing system. Workflow that works for you

Workflow that works for you. Diagnostic ECG. ST80i stress-testing system

Computed tomography. High. performance. no trade-offs. Philips Ingenuity CT family

New Features & Web Solutions. IHE (Integrated Healthcare Environment) Enhanced PACS Features Web Integration

Reducing Unnecessary Medical Imaging Exposure

The American College of Radiology. Dose Index Registry. ABR PQI Project Description. July 3, 2012

On the Importance of Computation in Clinical Radiology

clinical workflow manager

From Isolation to Insights

Part 3 Oral Exam Content Guide

Context. Accessibility. Relevance.

Innovative ways radiology practices improve workflow

BACSOFT IOT PLATFORM: A COMPLETE SOLUTION FOR ADVANCED IOT AND M2M APPLICATIONS

What Do You Need to Ensure a Successful Transition to IoT?

Feel the power of an integrated PACS!

Quality and Safety Analytics as a Pathway to Evidence Based Imaging Practice

Mach7 Enterprise Imaging Platform UnPAC and Build Your Own

CREATE INSTANT VISIBILITY INTO KEY MANUFACTURING METRICS

Streamline workflow for higher productivity and patient throughput. DirectView. Classic CR System

Centricity * Precision Reporting

1. Executive Summary

FILMLESS operation has been touted as the

CARESTREAM DIRECTVIEW Max CR System

New Joint Commission Requirements for Fluoroscopy Services

Imaging Solutions. AccessSTAT business analytics with drill down on real time and history AccessVAULT vendor neutral archive in the cloud

Adopting an Enterprise Imaging Strategy:

RADIOLOGY WORKFLOW SOLUTIONS

Introducing a new take on efficient workflow: Deeply integrated clinical applications

Server Configuration Monitor

THE AMRITA EDGE AMRITA THE AMRITA EDGE

PEOPLE POWER IMAGINE TECHNOLOGY BUILT AROUND YOU A QUIET REVOLUTION IN

Nuacare HMS. PMS. LIMS. CMS. RIS

INTELLIGENT RECORDING FOR DECISIONS WITH CONFIDENCE

Transcription:

DoseWise Portal Take control of dose management across your organization

Key benefits Make data-informed decisions to improve patient care with support from dose tracking and advanced analytics Enhance efficiency and system utilization through an understanding of staff and equipment performance Demonstrate a commitment to quality, satisfaction, patient and staff safety with increased transparency 2

Enable dose management across your organization Take control with DoseWise Portal Hospitals and health systems are discovering new and more effective ways to provide high-quality, cost-effective care and improve patient and staff satisfaction. A critical component is strong radiation control and management. Industry organizations have come forward to reinforce their commitment to reducing radiation exposure. The new Joint Commission Standards (for USA) require more from hospitals concerning new insights into imaging radiology dose data. Effective July 1st, 2015, hospitals must track, record, and improve dose performance against external benchmarks. In Europe, new regulations are expected to be in place by 2018. The Philips DoseWise Portal solution is the only turnkey dose management solution that gives you control over patient dose and staff occupational dose. It increases transparency across the entire enterprise and enables you to make data-driven decisions concerning quality initiatives and radiation management. Table of contents Reduce radiation risk 4 Make data-informed decisions 6 Enhance efficiency and system utilization 8 Demonstrate a commitment to patient and staff safety 10 Connect your organization 12 DoseWise Portal key capabilities 15 3

Reduce radiation risk Healthcare professionals commit to new industry standards 4

No doubt you ve considered the growing importance dose tracking and dose optimization holds for your patients and staff. You ve made the reasonable decision to act aggressively to establish a dose management program. You are not alone. Professional associations including European Society of Radiology, American College of Radiology, and Radiological Society of North America, have formed steering committees to detail guidelines for improved radiation safety at hospitals. They are helping to define the parameters. ALARA and good dose management While the risk of radiation exposure through imaging scans is thought to be low and the diagnostic rewards generally high, any excess radiation is unacceptable. The principle of ALARA (As Low As Reasonably Achievable) is an acknowledged mandate followed by all imaging professionals. It is with this in mind that you strive to provide your patients with the best care possible at low dose. To accomplish this and adhere to ALARA, all radiation emitting imaging systems in your department/hospital/enterprise must be optimized and dose to patients justified. An innovative solution Integrating every system into one radiation dose management program is not an easy task. Diverse manufacturers, multiple modalities, and various models make this difficult. Philips steps up to the challenge by developing a single portal through which you can manage all of your X-ray modalities. Regardless of type, age, or manufacturer, any system can be linked to DoseWise Portal as long as some basic data elements are available. This cohesive integration gives you access to dose data, in a patient-centric, or staffcentric view that may have been unavailable before. Acting as the core component in your radiation dose management program, DoseWise Portal provides actionable information in the form of tailored reports, alerts, and advanced analytics. Prepared for regulatory compliance A strong dose management program can help you achieve compliance with new regulatory standards and reduce risk. DoseWise Portal is uniquely positioned to assist, as it collects, measures, analyzes, and reports patient radiation exposure across your organization. And it is the only solution that combines real-time staff radiation exposure with patient data in the interventional setting in combination with DoseAware Xtend. Are you ready for the new standards? The Joint Commission s revised requirements for diagnostic imaging services (USA) expect each hospital to: Document radiation dose index by exam and by machine Review and analyze dose data Identify and review dose metrics that exceed expected ranges Compare data with external benchmarks for each X-ray machine Review and keep CT imaging protocols current with accepted standards 5

Make data-informed decisions Optimize patient dose through exam protocol management Collecting, managing, and analyzing relevant dose information offers you the ability to improve the quality of patient care through informed decision-making. When real-time and historical patient dose data from across imaging modalities is centrally managed, you are empowered to standardize protocols throughout your enterprise. In this way, you optimize radiation dose for your patients. By continually reviewing and refining best practices, you identify opportunities to implement improvement initiatives. Intuitive data analysis DoseWise Portal provides advanced analytic tools such as customizable dashboards and drill-downs for multi-vendor/multi-modality imaging systems. Aggregated data can be reviewed in multiple ways. Use the interactive charting tools to create bar charts, scatter plots, box plots, and tables that display key dose metrics. To refer to specific graphs and charts in the future, just pin them to your dashboard where they will automatically refresh with live data. Versatile data sharing All of this information can be accessed via role-based user accounts (such as medical physicist, site administrator, and radiologist), allowing each staff member the ability to view reports that are suited to their particular need. DoseWise Portal receives data directly from the modality, or from your PACS. Individualized dashboards can be exported as PDF and sent via email to compare results with colleagues from around your institution or around the world. By simplifying implementation of best dose management practices, DoseWise Portal can help you establish a stronger quality system for patient care. Options for analysis are broad. For example, you can compare study dose metrics for all X-ray modalities, stratified by site, device, study description, and patient age range. You can analyze dose based on exam type, body part, technologist, or imaging unit. Additionally, you can configure custom dose alert levels and thresholds, set by exam and by site, with optional email notifications. 6

Comprehensive view of exams and equipment across your organization Receive alerts of items requiring your immediate attention Track dose utilization through standard charts or customize dashboards to meet your organization needs Create your own dashboard of graphs and charts that are useful to you Data analysis and statistical details easily within reach Within a few clicks retrieve individual patient views with cumulative dose histories Email notification of patients exceeding alert values of your choosing 7

8

Enhance efficiency and system utilization Manage cost by understanding staff and equipment performance With coordinated radiation control comes efficiency and performance. Based on a better understanding of staff and machine performance, you can improve department efficiency and system utilization. Designed to connect multi-vendor systems, DoseWise Portal helps your organization define patterns and initiate improvement improvement that not only impacts the patient experience, but that of your staff as well. System utilization Using the DoseWise Portal dashboards, you can easily see when certain systems are underutilized or have begun to show undesirable trends related to radiation dose. Once identified, you can further investigate to determine the root cause and make a plan to drive improved efficiency. Real-time staff measurement DoseWise Portal is the only dose management solution that combines real-time staff radiation exposure and patient data via a proprietary interface with Philips DoseAware Xtend* (part of the DoseAware family of radiation monitoring devices.) Real-time staff dosimetry drives awareness and promotes a culture of radiation safety among your interventional staff. As associated behavior becomes the norm, standardization, and efficiency gains can be realized. With DoseWise Portal, staff dose data is now quantitative and easily accessed. A permanent radiation safety threshold can be established. * DoseAware Xtend is not a legal dosimeter and does not replace a TLD or film badge DoseAware Xtend Detailed procedure-based feedback DoseAware Xtend monitors radiation exposure to your staff in the highest exposure environment in the hospital the interventional suite. Immediate feedback on scatter dose during the procedure allows the team to take real-time action and move toward reducing exposure. Post-procedure, retrospective analysis can simultaneously analyze staff and patient dose and give insights to the root causes of radiation events. 9

10

Demonstrate a commitment to patient and staff safety Dedication to satisfaction and quality With increased transparency, you can establish a point of differentiation from other caregivers based on your commitment to quality, satisfaction and safety. DoseWise Portal serves as an evidencebased foundation to make continuous dose management process improvements. As the only dose management solution that includes real-time staff radiation exposure, it advances your ability to promote workplace safety and increase staff satisfaction. It also helps facilitate regulatory compliance using intuitive software that securely integrates with medical information systems, such as PACS, RIS, and dictation systems. All information exports to the American College of Radiation (ACR) Dose Index Registry (DIR) and can report cumulative patient dose. Dose information can be added to the dictation report to assist in fulfilling regulatory requirements. A patient-centric approach DoseWise Portal is part of DoseWise Solutions, our patient-centric approach to promoting radiation safety throughout the continuum of care. By integrating tools, training, and advanced product technologies, you can achieve diagnostic image quality at low dose. Take control of patient care, staff safety, and regulatory compliance with Philips DoseWise Portal. Experience its exceptional benefits as the core component in your radiation dose management program. Philips, a radiology innovator with over 100 years of X-ray experience From the first Rotalix X-ray tube which promised a breakthrough in the fight against tuberculosis, to DoseWise Portal that gives healthcare providers more control over dose management, Philips remains committed to delivering innovative technology and services to improve patient health across the continuum of care. We ve got 100 years experience you ve got a future-proof dose management system. 11

Connect your organization Installation of Philips DoseWise Portal is via a local server (virtual or physical) and can be configured for department-wide, hospital-wide, or enterprise-wide service. Basic installation Dose related information is aggregated from multiple channels, including DICOM Radiation Dose Structured Reports, OCR on legacy dose sheets, Modality Performed Procedure Step (MPPS), or other image headers. DoseWise Portal web access Dictation system PACS / RIS DoseWise Portal server PET/CT (CT component) CT Interventional X-ray DoseAware Xtend Digital X-ray Mammography 12

Information control DoseWise Portal integrates with all X-ray modalities including CT, fluoroscopy/angiography, DR/CR radiography, and mammography systems. Efficiencies are realized through the ease with which dose information can be organized and system utilization maximized. As an example, the CT overview screen shows the median CTDI (dose index), SSDE (Water Equivalent Diameter) and DLP (dose length product), exposure trends, and threshold alerts by exam and for individual scanners. Information presentation is customizable, configurable between scanner names and institutional lexicons. Comprehensive integration into your established processes informs best practices. Basic IT/server requirements for local server* Quad-core 2.8GHz 8GB RAM (2) 500GB 7.2K RPM SATA 3Gbps 3.5i/RAID1 Gigabit Ethernet OS: Windows Server 2012R2 DoseWise Portal is accessible via any compatible web browser (Chrome, IE, Safari) * Requirements for very large multi-site customers may differ A scalable solution This dose-tracking solution is scalable from just a few connections to enterprise healthcare systems with multiple locations, all with role-based log in via a standard web browser. Large enterprise The DoseWise Portal installation can be scaled up to give a comprehensive view of dose across large multi-site distributed health systems. * Depending on exact configuration, multiple data collectors may be required. DoseWise Portal web access Dictation system DoseWise Portal server PACS Data collector PACS Data collector Data collector PACS CT Digital X-ray CT PET/CT Mammography CT Digital X-ray (CT component) Hospital 1 Hospital 2 Hospital 3 Mobile C-arm 13

DoseWise Portal key capabilities Intuitive interface and advanced analytics Overview page per modality containing full range of data attributes Simple, interactive and customizable graphing tools to create patient data charts Single dashboard overview of your custom created graphs and charts Advanced dosimetry metrics such as CT Size Specific Dose Estimates (SSDE) Historical patient dose data across imaging modalities Customized configurations Role-based user accounts (medical physicist, site administrator, radiologist) Data can be filtered by site, department and modality Dose alert levels and thresholds set by exam with optional email notifications Protocol standardization capability Calibration correction factor capability for fluoroscopy Interoperability and infrastructure Works with all X-ray modalities: CT, fluoroscopy / angiography, CR/DR, mammography Extraction of dose data from DICOM-SR, DICOM-SC (for OCR), MPPS, image headers May receive data directly from the modality or from PACS Reconciliation of patient information through DICOM Modality Worklist (MWL) Staff exposure from interventional procedures through proprietary interface with Philips DoseAware Xtend Ability to export text about procedure dose into dictation text through integration with leading dictation vendors Ability to export DICOM-SR to ACR Dose Index Registry Conformance with IHE REM profile External data access via OData Data storage through secure local cloud environment Remote installation and service (through Philips Remote Service network VPN) 14

15

2015 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice. Trademarks are the property of Koninklijke Philips N.V. (Royal Philips) or their respective owners. www.philips.com/dosewise 4522 991 10501 * APRIL 2015