6KW Grid Interactive Photovoltaic System

Similar documents
Home PV System Design

Site Report. Report Date 6/16/2016

Building and Safety Division Public Information

PV Module Right-Sizing for Microinverters

FY2017 SREC Registration Program (SRP) Final As-Built Technical Worksheet Instructions Page 1

2011 UC Solar Research Symposium

5.5 KW DC PV SYSTEM Optimal Location W Solar PV Panels 60 Cell 250W PV Module

RECOMMENDATIONS FOR EXPEDITED PERMITTING FOR SMALL PV SYSTEMS

NABCEP PV Technical Sales Job Task Analysis

Photovoltaic Systems II. EE 446/646 Fall 2013

A CASE STUDY OF A RESIDENTIAL PHOTOVOLTAIC SYSTEM WITH MICROINVERTERS

Reference Information:

ASSESSMENT AND DESIGN OF ROOFTOP SOLAR PV SYSTEM. Click to begin

NY State Unified Solar Permit

Basic technical information on solar PV

Solar Energy Modeling for Residential Applications

Basic of Bifacial. 1-1 What is Bifacial? 1-2 Terms related to Bifacial. Design guide for Bifacial

Basic technical information on solar PV

GRID-CONNECTED PV SYSTEMS (No Battery Storage) SYSTEM DESIGN GUIDELINES

AR No. # - Install Photovoltaic Array

GRID-CONNECTED PV SYSTEMS (No Battery Storage) SYSTEM DESIGN GUIDELINES FOR THE PACIFIC ISLANDS

Address of Installation Building Permit #

ALL PARTIES MUST SIGN SECTION F.

Green Star Photovoltaic Modelling Guidelines

City of Santa Monica Building and Safety Division Submittal Requirements Expedited Solar Photovoltaic (10 kw or Less)

Website:

Site Survey in Project Info Structural Info Electrical Info

Course Title: Advanced PV Design (PV201) (NRG 220) 5 credits (55 hours)

Loyalty One 163 kw PV Installation. Final Report January Technology. Monitoring. SolarCity Partnership. Best Practices.

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Design and Performance Analysis of a Grid Connected Solar Photovoltaic System

GRID-CONNECTED PV SYSTEMS SYSTEM DESIGN GUIDELINES

SOLAR ENERGY ASSESSMENT REPORT. For 80.5 kwp. Meteorological Data Source NASA-SSE. Date 18 October, Name of Place Uttar Pradesh.

CITY & COUNTY OF DENVER COMMUNITY PLANNING & DEVELOPMENT BUILDING PERMIT POLICY

Local Solar PV Systems Update

Solar PV design considerations ENERGY USE Energy Use Intensity (EUI)

Power Saver TM Program

Journal of American Science 2014;10(8) Software Design of Photovoltaic Grid-Connected Power Plants

Please fill out as much as information as possible and do not hesitate to contact us at 844-Solerus if you need any help. AHJ Name: Snow Load:

1. The plan needs to show compliance with the 2013 CEC, 2013 CBC and 2013 CRC. [ CBC] RESPONSE:

NY State Unified Solar Permit

NY State Unified Solar Permit

Toronto Fire Station # kw PV Installation Final Report January 2012

NY State Unified Solar Permit

NY State Unified Solar Permit

Small Scale Solar Permit Application

Rooftop Solar PV System Designers and Installers. Training Curriculum. APEC Secretariat

Santa Monica Fire Department SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINE 2008 TABLE OF CONTENTS

Beverly Hills Fire Department SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINE 2008 TABLE OF CONTENTS

4301 Wilson Blvd. Arlington, VA tel:

NY State Unified Solar Permit

PHOTOVOLTAIC (PV) SUBMITTAL REQUIREMENTS

CITY OF LA MESA FIRE DEPARTMENT SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINE

Reference: Photovoltaic Systems, p. 229

TallSlateTM Grandee Installation Manual

BURBANK FIRE DEPARTMENT 311 East Orange Grove Avenue, Burbank CA Fax

MARBLEHEAD FIRE DEPARTMENT Standard Operating Guideline Draft for Photovoltaic/Solar Installations

Monroe County s Path to Solar Energy: Western New York s Largest Municipal Solar Installation

SUBMITTAL REQUIREMENTS FOR EXPEDITED ROOF TOP SOLAR PERMITTING

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan)

An inverter is the heart of a solar PV installation and it plays a critical role in maximizing energy harvest.

PERFORMANCE MONITORING AND EVALUATION OF A 1.72 KW P GRID-CONNECTED PV SYSTEM

Solar PV Performance and New Technologies in Northern Latitude Regions

LECTURE 15 PHOTOVOLTAIC MATERIALS. ECE 371 Sustainable Energy Systems

Request for Proposals for Photovoltaic System Installation

Lafayette Tower th St. NW, Washington D.C.

SOLARPVSYSTEM INFORMATIONPACK FIT PROGRAM

CSI Incentive Calculator User Guide

Solar PV design considerations ENERGY USE. How much energy will this building use?

NY State Unified Solar Permit

Solar America Board for Codes and Standards. For more information, visit the Solar ABCs web site:

INCREASING PV SYSTEM PERFORMANCE WITH ACTIVE POWER MANAGEMENT

Compactness ratio : 1.2. Openings ratio : 26% (thermic envelope / inhabitable area) Smaller is better 1.9 = bad < 0.8 = good

Power System Implementation and Demonstration at Camp Katuu, Palau

WITH THE TITLE 24. replacement. story. stories, etc. R disconnects. to, PV. unit and any. supporting frame. conditions. greater than the main

Expedited Permit Process for PV Systems Micro-Inverter

EcolibriumSolar. Customer Info. Project Info. System Info. Project Design Variables. Name: Phone:

GUIDELINES FOR PLAN CHECK AND PERMIT REQUIREMENTS FOR SOLAR ENERGY SYSTEMS

Proposal Data. Submittal Form

Performance Analysis of PV Solar Power System

NY State Unified Solar Permit

TallSlate TM with BITERS Installation Manual

Environmental concerns/reduce carbon emissions Save money on electric bills General interest in new technologies Increase in building value

Performance Parameters for Grid-Connected PV Systems

Anchorage Alaska Solar Tour: Saturday, June 17th, 2017 Tour Starts At 10am

IX. ADDITION OF SOLYNDRA SOLAR PANELS (ELECTRICAL BREADTH)

A technique for accurate energy yields prediction of photovoltaic system

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

APS microinverter commissioning checklist

A New Type of Hybrid Groundwater Energy System

NY State Unified Solar Permit

REQUEST FOR BID (TURNKEY SOLUTION) 1MW GRID TIE SOLAR PV POWER PLANT. Location:

Photovoltaic Energy Systems A Feasibility Study

NY State Unified Solar Permit

Global Top 10 Trackers for 2016 GTM Research

International Journal of Advance Research in Engineering, Science & Technology

Dubuque County West Campus Secondary Roads Shop Solar Array Bid Documents and Specifications. Notice to Bidders

Photovoltaic System Installation Request for Proposals. Notus Junior-Senior High School Notus, ID

Guideline for Fire Safety. Elements of Solar. Photovoltaic Systems

NY State Unified Solar Permit

Transcription:

6KW Grid Interactive Photovoltaic System System Summary Provided by Ben Nelson Account Project: Nelson Residence Solar Garage Verdiseno, Inc., its subsidiaries, officers, directors, employees and its suppliers specifically disclaim any implied warranties or representations that the information contained in this document ("Document") is complete or error-free. This Document is not provided as an engineering service and Verdiseno, Inc. is not an engineering firm. This Document is provided as an aid to those involved in the potential purchase or installation of a PV system, and is meant to facilitate the production of a final PV system design ("Design") by a qualified professional. This document does not contain enough information to fully represent a system design and should not be relied upon to perform an installation. If you require a Design that has been produced or approved by a qualified engineer, please be advised that you will need to hire a qualified engineer to produce or approve the needed Design and related documents. Please refer to the Terms and Conditions page at solardesigntool.com for the full Terms and Conditions agreement.

1. System Summary 1.1. System Data 1.1.1. Summary Location Info Climate Data Source Location Latitude Longitude Design Low Temperature Design High Temperature Oconomowoc, WI 53066 United States 43 06'N 88 30'W -11 F (-24 C) 90 F (32 C) Electrical Characteristics Summary Inverter (24) Enphase M250-60-2LL-S22-IG Module Helios Solar 6T-250 (250W) Number of Modules 24 Array Circuits 1 branch of 16 (16.0A), 1 branch of 8 (8.0A) STC power of array 6,000W PTC power of array 5,400W CEC power output 5,211W Max AC output current 24A First-Year PV Watts Prod. Estimate 7,603kWhr

1.2. Array Layout 1.2.1. Roof Face South Installation Area Installation area length 29ft Installation area width 18ft Slope 7/12 (30.3 ) Installation area azimuth 180 (S) Configured Layout Column spacing 0.25in Row spacing 1in Module orientation portrait Distance between tilted racks 1in Tilt angle of modules 0 Clearance at left 17.24in Clearance at right 17.24in Clearance at top 15.72in Clearance at bottom 0ft Total number of modules 24 Total number of rows 3 Layout length 26.13ft Layout width 16.48ft Area of array 429.66ft² Max. Values for Installation Area Max no. of modules 24 Maximum no. of rows 3 Max no. of modules in a row 8 Maximum row length 26.13ft Maximum column length 16.48ft Area if layout full 432.58ft²

18ft RAKE 29ft RIDGE EAVE RAKE

2. System Design Calculations Report (Non-Code) 2.1. PV Source Circuit Voltage Range Test This test confirms that the voltage of the PV Source Circuit will always remain within the DC input voltage window of the system's inverter, microinverters, or power optimizers. 2.1.1. (1) 6T-250 (250W) in series Section Properties Description (1) 6T-250 (250W) in series Connected Device M250-60-2LL-S22-IG Connected Device Type Microinverter Design Low Temp. -24 C Design High Temp. 32 C Module 6T-250 (250W) Module Vmp 30.3V Module Voc 37.4V Microinverter Min. Input Voltage 16V Microinverter Max. Input Voltage 48V Mounting Method Flush Roof Mount Temp. Coefficient Voc -0.12V/C Voltage Loss Due to Degradation 0.0 derate Voltage Loss Due to Tolerance 0.0 derate Inverter Min. Voltage Increase Due 0.0 to High Temperatures Calculations A. String Voc at Low Temperature 43.28V The module Voc (37.4V) will increase to 43.28V at the design low temperature (-24 C). (-24 C - 25 C) X -0.12V/C + 37.4V = 43.28V The total Voc for the string is 43.28V. 43.28V X 1 = 43.28V B. String Vmp at High Temperature 25.26V Estimated cell temperature equals the design high temperature (32 C) plus 35 C (the estimated difference between ambient temperatures and the cell temperature for a flush roof mount). 32 C + 35 C = 67 C The module Vmp (30.3V) will drop to 25.26V at the design high temperature (32 C). (67 C - 25 C) X -0.12V/C + 30.3V = 25.26V The total Vmp for the string is 25.26V. 25.26V X 1 = 25.26V Validation Tests 1. The minimum Vmp must exceed the minimum input voltage of the connected device 25.26V > 16V = true 2. The maximum Voc must not exceed the max input voltage of the connected device 43.28V < 48V = true PASS PASS