WIND TURBINES. Vibration Control of: Wind Turbines APPLICATIONS POWER GENERATION - WIND TURBINES

Similar documents
Concert Halls, Lyric Theatres and Performing Arts Venues

POWER PRESSES. Vibration Control, Mounting and Levelling of: Power Presses APPLICATIONS. Presses come in various categories including:

ROSTA Anti-vibration Mountings

Comparative Impact Performances of Lightweight Gym Floors

VIBRATION CONTROL SYSTEMS FOR TRACKBEDS AND BUILDINGS USING COIL STEEL SPRINGS

What are Roll Grinding machines and where are they generally located?

PUMPS/ COMPRESSORS. Mounting, Levelling and Vibration Control of: Pumps. Compressors POWER GENERATION - PUMPS & COMPRESSORS

PUMPS/ COMPRESSORS. Mounting, Levelling and Vibration Control of: Pumps. Compressors POWER GENERATION - PUMPS & COMPRESSORS

NODALIZATION OF ISOLATOR FOR FLOATING FLOOR DESIGN. C.K. Hui and C. F. Ng

2.15 Tokamak Seismic Analysis

Warwick FRP Bridge: Design and Performance

Technical Assignment #3 November 15, 2004 Lateral System Analysis and Confirmation Design

Printing Presses come in various types but can be divided into 2 basic types;

CATALOG VIBRATION ISOLATORS CIRCULAR CUSHYFOOT CUP MOUNT SANDWICH MOUNTS BOBBINS & BUFFERS

VIBRATION CONTROL FOR A 25 MW STEAM-TURBINE GENERATOR INSTALLATION NEAR ACADEMIC TEACHING AND RESEARCH LABORATORIES

Acoustic Vibration Isolation Bearings

Table of Contents.2. Introduction...3 Gravity Loading and Deflections..4. Existing Structural System..8

GARAGE STRUCTURE VIBRATION TRANSMISSION TO HUMAN OCCUPIED SPACES

LASD Coatings Optimized for Damping of Aluminum Intensive Vehicle Bodies

BY: United Plastics Corporation 511 Hay Street Mount Airy, NC (800)

DESIGN OF A TUNEABLE DAMPED SPRING SYSTEM FOR GYM TREADMILL ISOLATION

2 FIGURE -1

Basic quantities of earthquake engineering. Strength Stiffness - Ductility

CE 6071 Structural Dynamics and Earthquake Engineering UNIT -5 2 MARKS

The Role of Cinema in the Leisure Environment

Part III Special Topics of Bridges

Vibration Isolation of Machine Foundations

Forced vibration testing of a thirteen storey concrete building

JOURNAL OF CIVIL ENGINEERING AND TECHNOLOGY (JCIET) INNOVATIVE ISOLATION TECHNIQUES FOR SEISMIC FORCES. Ar.Anurakti Yadav LNCT College, Bhopal

CHAPTER I INTRODUCTION AND LITERATURE REVIEW

DAMPING LOSS FACTOR ESTIMATION BY EXPERIMENTAL METHOD FOR PLATE WITH CONVETIONAL AND COMPOSITE MATERIALS

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Division 15 VIBRATION ISOLATION AND SILENCERS Section Page 1 of 6

Fluid Viscous Dampers to reduce Wind-induced Vibrations in Tall Buildings

Modal analysis and flanking sound insulation in connected panels of cross-laminated-timber at low frequencies

Examples of timber-frame buildings in the Netherlands

Base isolation. Philippe Bisch IOSIS, EGIS group. EUROCODE 8 Background and Applications

Tackling the Whining Noise of a 4WD Bus A Case Study

EXPERIMENTAL AND FINITE ELEMENTS ANALYSIS OF A TUNED MASS ABSORBER FOR VIBRATION ISOLATION

Vibration Isolation of Machine Foundations. Active and Passive Isolation

COMPARISON OF POOL ISOLATION SYSTEMS

CATALOG VIBRATION ISOLATORS CIRCULAR CUSHYFOOT CUP MOUNT SANDWICH MOUNTS BOBBINS & BUFFERS

Final year projects offered by Professor Jie Pan ( )

Belleville Spring. The relation between the load F and the axial deflection y of each disc. Maximum stress induced at the inner edge

Control of variable frequency vibration in large span composite construction floor in a high rise building

TONAL NOISE MITIGATION ON WIND TURBINES

Vibration Isolation of Buildings. Resilient Bedding of Buildings

Vibratec Akustikprodukter AB Civil Engineering

Building Isolation Design for Noise Critical Applications

Seismic Analysis and Design of Vertically Irregular RC Building Frames

Noise and Vibration Sources and Mitigation in Green Buildings

RIVER PUMP ROOM ISOLATION FROM STATE LIBRARY. David Borgeaud 1 and Michael Plumb 2. Brisbane, QLD 4000, Australia 2 GP Embelton & Co.

Experimental investigations on acoustical retrofitting of timber floors

WIND TUNNEL STUDIES AND THEIR VALIDATIONS WITH FIELD MEASUREMENTS FOR A SUPER-TALL BUILDING

STAAD.pro 2007 Design of Wind Turbine Foundations

Engr. Thaung Htut Aung M. Eng. Asian Institute of Technology Deputy Project Director, AIT Consulting

EXPERIMENTAL STUDY ON VIBRATION BEHAVIOR OF COLD-FORM STEEL CONCRETE COMPOSITE FLOOR

Optimized Skid Design for Compressor Packages

II-100 II-101 INTRODUCTION

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

Seismic Protection of Lead-Cooled Reactors

ROOF MOUNT KIT OWNERS MANUAL

SILENTFLEX FLOATING SLAB

MECHANICS OF DRILLSTRINGS AND MARINE RISERS DON W. DAREING ASME PRESS

Analytical Model of Vibration Transmission Through the 5M10000 Mount

DAMPING IN TALL BUILDINGS AND TOWERS. This tutorial is a follow-up to Reference 1.

Nonlinear Dynamic Analysis of Base Isolated Reinforced Concrete Building

Vibration Control SCHWINGMETALL. The Original Rubber-To-Metal Bonding from ContiTech

eight plates and grids APPLIED ACHITECTURAL STRUCTURES: DR. ANNE NICHOLS SPRING 2018 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

RESPONSE OF GROUND SUPPORTED CYLINDRICAL TANKS TO HARMONIC LOADING

ROOF MOUNT KIT OWNERS MANUAL

OPTIMUM DAMPING IN ISOLATION SYSTEM

Vibration and Shock Isolation Systems for Forging Machinery

Lateral System Analysis and Confirmation Design (S-3)

BUILDING SYSTEMS NOISE CONTROL

Int. Journal for Housing Science, Vol.34, No.2 pp , 2010 Published in the United States

eight plates and grids Plates, Slabs & Grids Plates, Slabs & Grids Term Project plates horizontal plane, rigid slabs thin, flat, rigid

Flexible Structural Façade

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

1.0 INTRODUCTION BUILDING REGULATIONS SOUND INSULATION REQUIREMENTS TEST PROCEDURE AND ANALYSIS...3

Letter of Transmittal

Kiran K. Shetty & Krishnamoorthy Department of Civil Engineering, Manipal Institute of Technology, Manipal , Karnataka, India

Vibration Control by Tuned Liquid Dampers

LABORATORY MEASUREMENT OF THE SOUND REDUCTION IMPROVEMENT INDEX BY ACOUSTICAL LININGS DUE ONLY TO RESONANT TRANSMISSION

POST TENSIONED SLABS. Imagineering the possibilities

Specialist Study on Noise APPENDIX 4 : EXAMPLES OF GOOD OPERATING PRACTICES IN ORDER TO REDUCE NOISE EMISSIONS

5-story Residential Building

ACCELERATED REPLACEMENT OF STEEL PLATE RAILWAY BRIDGES USING MOVING CRANES ON RAILROAD

SLENDER PRECAST WALL PANELS INTERACTED WITH STEEL PORTAL FRAMES UNDER EARTHQUAKE LOADS

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

FLOOR STRUCTURES. Floor structures Building Construction I.

Sabah Shawkat Cabinet of Structural Engineering 2017

SPECIFICS OF NATURAL FREQUENCY MEASUREMENTS FOR FLOOR VIBRATION. Riga Technical University, Latvia

CHAPTER 4. 1:6-Scale Frame: Stiffness and Modal Testing 4.1 OVERVIEW

Vibration Isolation. No matter how advanced the design, mechanical equipment

151 First Side. Technical Assignment 2 November 16 th, William J. Buchko. AE 481w Senior Thesis The Pennsylvania State University

Preface to the First Edition Preface to the Second Edition. Acknowledgment

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

Transcription:

APPLICATIONS AP-Power-Wind Turbines-13a Vibration Control of: WIND TURBINES POWER GENERATION - WIND TURBINES Wind Turbines Wind power is popular. The market for wind turbines is expanding rapidly and with it is an increasing demand for turbines to be installed in urban areas. This can be problematic due to turbulence and the lack of consistent wind and means that they need to be located above the city on the roofs of buildings or other structures. Placing wind turbines on roofs has a number of challenges such as; Access Capacity to support the applied forces Anticipated requirement for specialised support structures for stability Proximity to high spec building use such as penthouses Risk of resonance in the building structure Vibration isolation performance is very dependent on the turbine type, the building design, and building use Each turbine design has its own operating characteristics and more importantly each roof structure and potential mounting arrangement will vary meaning that a bespoke system needs to be designed based a number of factors and must include; Structural Integrity vs Vibration Control vs Operating Performance vs Practicalities.

01 Design Consideration 01 performance Roof structures tend to be light in weight and strength and therefore are good transmitters of vibration. Usually specialist wind turbine support frames need to be designed to provide sufficient strength by connecting the frame to the main columns from the building which in turn creates a direct transmission path from turbine to the main building structure. Vibration from wind turbines can either generate vibration or, worse, resonate parts of the structure causing vibration and reradiated noise disturbance within the building. The vibration of the turbines can come from two sources: Unpredictable mechanical friction, unbalancing of the rotor, wind gust related. Depending on the maximum rotor speed, these vibrations will tend to be below 10Hz. The second type of predictable vibration is linked to the generator operation, and micro pulses due to the electronics of the turbine. These vibrations will range from ~100Hz to ~400Hz (varying with the rotor speed). Depending on the stiffness of the mounting system, 2nd and 3rd harmonics can appear on the vibration spectrum. Therefore, we need to consider the complete range of vibration from 100Hz to ~1.2kHz (400Hz*3rd harmonic). However, the energy from the 2nd and 3rd harmonics are a lot lower than the first one. roof which will be the most efficient transmitter of vibration energy as noise into the building and from a practical point of view they should not be affected by, or affect the insulation and waterproofing systems on the roof. Most human ears can hear sounds of frequencies ranging between 20Hz and 20kHz. However, the frequency response of the human ear is such that low frequency sounds appear less loud than high frequencies. This is commonly accounted for by weighting the sound pressure level. A-weighting, for example, provides a relatively accurate measurement of perceived loudness. Vibration transmission from wind turbines into a building is undesirable because it can be heard. Farrat has a significant amount of experience in the successful design of vibration control systems for roof mounted wind turbines. The solutions in each case were driven by the constraints but generally resulted in a bolted through or full decoupled push-pull connection using high damping elastomeric materials. Factors to consider in obtaining a solution are; 1. Positioning- Since structural integrity is critical and such support frames cannot be avoided then vibration control needs to be incorporated somewhere between the turbine mast and the building structure. From a structural point of view they need to be located to ensure that the structure retains sufficient stiffness. The forces from the wind turbine can lead to torsion and shear loadings. From an acoustic point of view they should be above the

02 performance (Cont) 2. Allowable movement - A primary constraint in vibration control of wind turbines is allowable movement. A small movement at the base of a turbine will be amplified at the top of the mast so a first question to consider is how much movement can be permitted at the top of the mast and then what is the max allowable movement at the point where the vibration control solution is to be applied. Often this value will be very low and therefore means that, high resilience, low frequency solutions such as springs or pads cannot be used. Adding mass by way of an inertial block is a very effective way of reducing vibration disturbance (2x mass = 0.5 vibration), increasing stability by lowering the centre of gravity and allowing the use of lower frequency isolators but as we know roof structures are lightweight and usually cannot permit significant addition of mass. 3. Modelling - The entire system needs to be considered as a 3d model rather than a simple mass on springs isolation model. Rocking and modal behaviour of the turbine structure have to be considered. For any roof mounted wind turbine application it is very important to establish the operating frequencies of the turbine as well as the natural frequency of the mounting, roof and building structure to see what the combined effects might be. This usually needs to be done with modelling. Dynamic modelling of the entire system is also important when you consider that once resilient materials have been incorporated into a connection the natural frequency of the frame will alter. The natural frequency of beams and masts will decrease once they are resiliently connected as opposed to if they were rigidly connected. 4. Natural frequency - is derived from mass of system rather than applied wind loads (wind load should not be considered as a mass) so the dynamic spring constant of the bolted through (push pull) connection is critical to real performance. Dynamic natural frequency does not necessarily equate to the calculated (mass spring) natural frequency. provide suitable resilience at normal wind speeds whilst still being able to accept peak wind loadings. The isolation connection design should be pre-compressed to ensure that as the connection deflects or up-lifts it does not loose tension in the connection. Pads must stay in contact with frame even under peak load (6-7x normal load). This puts an extra emphasis on the anti-vibration material to be able to withstand very high loads whilst still offering resilience at low loads. 65 Total moment Head Thrust Weight 5. Damping - Damping plays a crucial role in wind turbine isolation as it dissipates energy in a vibrating system and converts that energy to heat. It is essential to control the potential high levels of transient vibration and shock, particularly if the system is excited at, or near, to its resonant frequency. Damping is required where movement of the supported equipment must be minimised especially at resonance and when shock is to be absorbed. 6. Light weight but high forces - Roof mounted wind turbines tend to be very light whilst peak wind speeds are significantly higher (6-7x) than typical wind speeds so it is difficult to design a mounting system that can

03 performance (Cont) 7. Bespoke vs off the shelf - Many off the shelf wind turbine isolation systems are designed for installation on the ground or concrete and brick structures (which are very good to damp vibration) which means they may not offer adequate vibration control performance for steel structures. Example of Farrat s success and experience in designing high performance vibration control solutions for roof mounted wind turbines we were asked to provide an alternative design to an existing application where a competitors solution was installed but not providing adequate performance. The following is an exert from the conclusions of the vibration consultant s findings; The 8 hour average results demonstrate that the typical background vibration levels fall well below the ASHRAE guideline levels for Residential (good environmental standards) of 2.032e-4m/s (8000µIn/s). In addition, over the key frequency band of 10-15Hz that was seen previously to be responsible for vibration issues, the modified system design coupled with Farrat Isolation resulted in a 53.8% and 72.5% reduction over the February 2011 and September 2011 surveys respectively. In another example the findings were as follows; Levels of vibration in the flat immediately below the turbine was well below that known to cause nuisance or discomfort. The turbine s control panel dominates the vibration measured in the flat in the X, Y and Z directions. Furthermore they did not show any correlation to wind speed. No measurable impact on noise levels both externally and within the flat due to operation of the turbine Vibration levels within the flat are well below the comfort criteria for 24hr working. Solutions Farrat Damping Pads (NBR, Squaregrip, IMBR)

APPLICATIONS AP-Power-Wind Turbines-13a Vibration Control of: WIND TURBINES POWER GENERATION - WIND TURBINES Wind Turbines Wind power is popular. The market for wind turbines is expanding rapidly and with it is an increasing demand for turbines to be installed in urban areas. This can be problematic due to turbulence and the lack of consistent wind and means that they need to be located above the city on the roofs of buildings or other structures. Placing wind turbines on roofs has a number of challenges such as; Access Capacity to support the applied forces Anticipated requirement for specialised support structures for stability Proximity to high spec building use such as penthouses Risk of resonance in the building structure Vibration isolation performance is very dependent on the turbine type, the building design, and building use Each turbine design has its own operating characteristics and more importantly each roof structure and potential mounting arrangement will vary meaning that a bespoke system needs to be designed based a number of factors and must include; Structural Integrity vs Vibration Control vs Operating Performance vs Practicalities.