SECTION C. Water Infiltration: Provide manufactured cupolas and dormers that do not allow water infiltration to cupola and dormer interiors.

Architectural Roof and Wall Products Guide Specifications

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION METAL ROOF PANELS

SECTION TERMITE CONTROL. A. Product Data: For each type of product indicated. Include the EPA-Registered Label for termiticide products.

SECTION METAL ROOF PANELS. A. Vertical-rib, seamed joint, standing seam metal roof panels, with related metal trim and accessories.

Architectural Roof and Wall Products Guide Specifications

Gypsum Board

SECTION STANDING SEAM METAL ROOFING

SECTION METAL ROOF AND SOFFIT PANELS

SECTION ROOF SPECIALTIES

SECTION METAL ROOF PANELS PART 1- GENERAL 1.1 RELATED DOCUMENTS

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

SECTION STANDING-SEAM METAL ROOF PANEL

C. Counterflashings at roof-mounted mechanical equipment, vent stacks, curbs, and miscellaneous roof penetrations.

Hollow Metal Doors and Frames

SECTION AWNINGS

SECTION PREFORMED METAL ROOFING - REVISION 1

SECTION COPPER STANDING SEAM ROOFING

Union County Vocational - Technical Schools Scotch Plains, New Jersey

DL-200. Specifications

Product Guide Specification

1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920

SECTION ROOF SPECIALTIES

SECTION TURBINE VENTILATORS

Architectural Wall Products Guide Specifications

SECTION MANUFACTURED ROOF EXPANSION JOINTS

Aluminum-Framed Entrances and Storefronts

Trapezoidal-rib, snap joint, standing seam metal roof panels, with related metal trim and accessories.

University of New Hampshire Scholars' Repository

ADDENDUM TO BID DOCUMENTS SCCD RFP: # Vacaville Classroom Building (Annex) Renovation. Date: 11/16/2017

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

TYPICAL ROOF CONDITION LAYOUT

SECTION METAL FLAT LOCK TILE PANELS

SSL-175. Specifications

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

A. Provide all labor, equipment, and materials fabricate and install the following. 2. Counterflashings over bituminous base flashing.

NRM-7000 Guide Specifications

Thermal Insulation

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

Drexel Metals Inc. DMC 5V 26 Gauge min. Face-Fastening Metal Roof System over Plywood

IF YOU DO NOT SEE INSTRUCTIONS IN BLUE TYPE ABOVE THIS NOTE, PLEASE ACTIVATE HIDDEN TEXT AS INDICATED:

SECTION ROOF MOUNTED ATTIC EXHAUST VENT

SECTION METAL ROOF PANELS

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

SECTION SHEET MEMBRANE ROOFING

Hawthorne Fire Station Repairs Section Page 1 of 8

Magnolia Transit Center Expansion SECTION METAL SOFFIT PANELS

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

Specifications for FL-100 Soffit Panel

Multi-Institutional Academic Health Science & Research Center Evansville, IN

1. Engineer metal building systems according to procedures in MBMA's "Metal Building Systems Manual." 2. Design Loads: As indicated on Drawings.

CS-100 Guide Specifications

SECTION NON--STRUCTURAL METAL FRAMING

SECTION BATTEN SEAM COPPER ROOFING

SECTION LINEAR METAL CEILINGS

1. Include similar Samples of trim and accessories involving color selection.

A. Metal Building System Description: Rigid modular, with interior columns with expandable endwall.

University of Louisville February 22, 2017 Papa John s Cardinal Stadium -North Expansion Bid Package No. 5 Louisville, Kentucky

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

SECTION METAL ROOF PANELS

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

University of New Hampshire Scholars' Repository

University of New Hampshire Scholars' Repository

SECTION METAL FLOOR PLATE STAIRS

6. ENGINEERING SYSTEMS REQUIREMENTS B30 ROOFING B30 GENERAL SYSTEM DESCRIPTION

6. ENGINEERING SYSTEMS REQUIREMENTS B30 ROOFING B30 GENERAL SYSTEM DESCRIPTION

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

PRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB ADPH #B

SECTION ALUMINUM HANDRAIL SYSTEMS

Multi-Institutional Academic Health Science & Research Center Evansville, IN

6. ENGINEERING SYSTEMS REQUIREMENTS B30 ROOFING B30 GENERAL SYSTEM DESCRIPTION

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated.

SECTION METAL ROOF PANEL, STANDING SEAM - SRS3

COMPOSITESIDING

SHEET METAL FLASHING AND TRIM

SECTION HVAC GRAVITY VENTILATORS

SECTION WALL AND DOOR PROTECTION

A. This Section includes the following types of visual display boards: 1. Porcelain enamel markerboards (for liquid chalk).

SECTION ELECTRICAL POWER ATTIC EXHAUST VENTILATOR

B. Shop Drawings: For the following metal building system components. Include plans, elevations, sections, details, and attachments to other work.

DIVISION 7: MOISTURE PROTECTION SECTION 07417: INSULATED METAL PANELS

IF YOU DO NOT SEE INSTRUCTIONS IN BLUE TYPE ABOVE THIS NOTE, PLEASE ACTIVATE HIDDEN TEXT AS INDICATED:

B. Shop Drawings: Show fabrication and installation details for roof accessories.

SECTION PRE-ENGINEERED METAL BUILDING

SECTION ROOF ACCESSORIES

Student Services & Classroom Addition

Metl-Span ShadowRib Formed Metal Wall Panels

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Metl-Span FW-120 Formed Metal Wall Panels

SECTION THERMAL INSULATION

SECTION 1 - ETHYLENE-PROPYLENE-DIENE-MONOMER (EPDM) ROOFING

Transcription:

University of New Hampshire University of New Hampshire Scholars' Repository Division 07 Thermal and Moisture Protection Chapter 5 Technical Construction and Renovation Standards 1-25-2013 074113 - Metal Roof Panels Sandra Hickey sandra.hickey@unh.edu Follow this and additional works at: http://scholars.unh.edu/pdch_5_07 Recommended Citation Hickey, Sandra, "074113 - Metal Roof Panels" (2013). Division 07 Thermal and Moisture Protection. 9. http://scholars.unh.edu/pdch_5_07/9 This Article is brought to you for free and open access by the Chapter 5 Technical Construction and Renovation Standards at University of New Hampshire Scholars' Repository. It has been accepted for inclusion in Division 07 Thermal and Moisture Protection by an authorized administrator of University of New Hampshire Scholars' Repository. For more information, please contact nicole.hentz@unh.edu.

074113 - Metal Roof Panels This article is available at University of New Hampshire Scholars' Repository: http://scholars.unh.edu/pdch_5_07/9

SECTION 07 4113 - METAL ROOF PANELS 1.1 SUMMARY A. The university prefers to use regional materials within a 500 mile radius of the campus. B. Section Includes: 1. Concealed-fastener, lap-seam metal roof panels. 2. Standing-seam metal roof panels. 1.2 DEFINITIONS A. Metal Roof Panel Assembly: Metal roof panels, attachment system components, miscellaneous metal framing, thermal insulation, and accessories necessary for a complete weathertight roofing system. 1.3 PERFORMANCE REQUIREMENTS A. General Performance: Metal roof panels shall comply with performance requirements without failure due to defective manufacture, fabrication, installation, or other defects in construction. B. Delegated Design: Design metal roof panel assembly, including comprehensive engineering analysis by a qualified professional engineer, using performance requirements and design criteria indicated. C. Energy Performance: Provide roof panels with solar reflectance index not less than 29 when calculated according to ASTM E 1980 based on testing identical products by a qualified testing agency. 1.4 SUBMITTALS A. LEED Submittals: 1. Product Test Reports for Credit SS 7.2: For roof panels, indicating that panels comply with solar reflectance index requirement. 2. Product Data for Credit MR 4.1 and Credit MR 4.2: Indicating percentages by weight of postconsumer and preconsumer recycled content for products having recycled content. a. Include statement indicating costs for each product having recycled content. B. Manufacturer Certificates: Signed by manufacturer certifying that roof panels comply with energy performance requirements specified in "Performance Requirements" Article. METAL ROOF PANELS 07 4113-1

1. Submit evidence of meeting performance requirements. 1.5 QUALITY ASSURANCE A. Surface-Burning Characteristics: Provide metal roof panels having insulation core material with the following surface-burning characteristics as determined by testing identical products according to ASTM E 84 by a qualified testing agency. Identify products with appropriate markings of applicable testing agency. 1. Flame-Spread Index: 25 or less. 2. Smoke-Developed Index: 450 or less. B. Fire-Resistance Ratings: Where indicated, provide metal roof panels identical to those of assemblies tested for fire resistance per ASTM E 119 by a qualified testing agency. Identify products with appropriate markings of applicable testing agency. 1. Indicate design designations from UL's "Fire Resistance Directory" or from the listings of another qualified testing agency. 2. Combustion Characteristics: ASTM E 136. 1.6 PANEL MATERIALS A. Metallic-Coated Steel Sheet: Restricted flatness steel sheet metallic coated by the hotdip process and prepainted by the coil-coating process to comply with ASTM A 755/A 755M. 1. Recycled Content: Provide steel sheet with average recycled content such that postconsumer recycled content plus one-half of preconsumer recycled content is not less than 25 percent. 2. Zinc-Coated (Galvanized) Steel Sheet: ASTM A 653/A 653M, G90 (Z275) coating designation; structural quality. 3. Aluminum-Zinc Alloy-Coated Steel Sheet: ASTM A 792/A 792M, Class AZ50 coating designation, Grade 40 (Class AZM150 coating designation, Grade 275); structural quality. 4. Surface: Smooth, flat finish. B. Aluminum Sheet: Coil-coated sheet, ASTM B 209 (ASTM B 209M), alloy as standard with manufacturer, with temper as required to suit forming operations and structural performance required. 1. Surface: Smooth, flat finish. C. Copper Sheet: ASTM B 370, cold-rolled copper sheet, H00 temper. 1.7 UNDERLAYMENT MATERIALS A. Self-Adhering, High-Temperature Sheet: 30 to 40 mils (0.76 to 1.0 mm) thick minimum, consisting of slip-resisting, polyethylene-film top surface laminated to layer of METAL ROOF PANELS 07 4113-2

butyl or SBS-modified asphalt adhesive, with release-paper backing; cold applied. Provide primer when recommended by underlayment manufacturer. 1. Thermal Stability: Stable after testing at 240 deg F (116 deg C); ASTM D 1970. 2. Low-Temperature Flexibility: Passes after testing at minus 20 deg F (29 deg C); ASTM D 1970. 3. Products: a. Carlisle Coatings & Waterproofing Inc., Div. of Carlisle Companies Inc.; CCW WIP 300HT. b. Grace Construction Products; a unit of Grace, W. R. & Co.; Ultra. c. Henry Company; Blueskin PE200 HT. d. Metal-Fab Manufacturing, LLC; MetShield. e. Owens Corning; WeatherLock Metal High Temperature Underlayment. B. Felts: ASTM D 226, Type I (No. 15), asphalt-saturated organic felts. C. Slip Sheet: Manufacturer's recommended slip sheet, of type required for application. 1.8 CONCEALED-FASTENER, LAP-SEAM METAL ROOF PANELS A. General: Provide factory-formed metal roof panels designed to be installed by lapping and interconnecting side edges of adjacent panels and mechanically attaching through panel to supports using concealed fasteners and factory-applied sealant in side laps. Include accessories required for weathertight installation. B. Standing-Seam-Profile, Concealed-Fastener Metal Roof Panels: Formed with raised, curved-top, standing-seam-shaped major rib at panel edge and flat pan between major rib and panel edge. 1.9 STANDING-SEAM METAL ROOF PANELS A. General: Provide factory-formed metal roof panels designed to be installed by lapping and interconnecting raised side edges of adjacent panels with joint type indicated and mechanically attaching panels to supports using concealed clips in side laps. Include clips, cleats, pressure plates, and accessories required for weathertight installation. 1. Steel Panel Systems: Unless more stringent requirements are indicated, comply with ASTM E 1514. 2. Aluminum Panel Systems: Unless more stringent requirements are indicated, comply with ASTM E 1637. B. Vertical-Rib, Snap-Joint, Standing-Seam Metal Roof Panels: Formed with vertical ribs at panel edges and flat pan between ribs; designed for sequential installation by mechanically attaching panels to supports using concealed clips located under one side of panels and engaging opposite edge of adjacent panels, and snapping panels together. METAL ROOF PANELS 07 4113-3

C. Vertical-Rib, Seamed-Joint, Standing-Seam Metal Roof Panels: Formed with vertical ribs at panel edges and flat pan between ribs; designed for sequential installation by mechanically attaching panels to supports using concealed clips located under one side of panels and engaging opposite edge of adjacent panels, and mechanically seaming panels together. D. Trapezoidal-Rib, Snap-Joint, Standing-Seam Metal Roof Panels: Formed with raised trapezoidal ribs at panel edges and flat pan between ribs; designed for sequential installation by mechanically attaching panels to supports using concealed clips located under one side of panels and engaging opposite edge of adjacent panels, and snapping panels together. E. Trapezoidal-Rib, Seamed-Joint, Standing-Seam Metal Roof Panels: Formed with raised trapezoidal ribs at panel edges and flat pan between ribs; designed for sequential installation by mechanically attaching panels to supports using concealed clips located under one side of panels and engaging opposite edge of adjacent panels, and mechanically seaming panels together. F. Integral-Standing-Seam Metal Roof Panels: Formed with integral ribs at panel edges and flat pan between ribs; designed for sequential installation by mechanically attaching panels to supports using concealed clips located under one side of panels and lapping and interconnecting side edges of adjacent panels. 1.10 ACCESSORIES A. Gutters: Formed from same material roof panels. Match profile of gable trim, complete with end pieces, outlet tubes, and other special pieces as required. Fabricate in minimum 96-inch- (2400-mm-) long sections, of size and metal thickness according to SMACNA's "Architectural Sheet Metal Manual." Furnish gutter supports spaced a maximum of 36 inches (900 mm) o.c., fabricated from same metal as gutters. Provide wire ball strainers of compatible metal at outlets. B. Downspouts: Formed from same material as roof panels. Fabricate in 10-foot- (3-m-) long sections, complete with formed elbows and offsets, of size and metal thickness according to SMACNA's "Architectural Sheet Metal Manual." Finish downspouts to match gutters. C. Roof Curbs: Fabricated from same material as roof panels, minimum 0.048 inch (1.2 mm) thick; with bottom of skirt profiled to match roof panel profiles, and welded top box and integral full-length cricket. Fabricate curb subframing of minimum 0.0598-inch- (1.5-mm-) thick, angle-, C-, or Z-shaped steel sheet. Fabricate curb and subframing to withstand indicated loads, of size and height indicated. Finish roof curbs to match metal roof panels. 1.11 SNOW GUARDS A. Snow Guards: Prefabricated, noncorrosive units designed to be installed without penetrating metal roof panels, and complete with predrilled holes, clamps, or hooks for anchoring. METAL ROOF PANELS 07 4113-4

1. Surface-Mounted, Copper, Stop-Type Snow Guards: Bronze-alloy stops designed for attachment to pan surface of copper roof panel using solder. END OF SECTION 07 4113 METAL ROOF PANELS 07 4113-5