Super Clean Gas Filters Simply the best

Similar documents
Super Clean Gas Filters Simply the best

Super Clean TM Gas Filters

Dräger Gas Filtration SUPER CLEAN GAS FILTERS. Dräger: Technology for Life

Gas Filtration Catalogue

TTE N TTE N

Alumina BOND/MAPD PLOT Columns!

GC Troubleshooting. Frank Michel, Katherine K. Stenerson T HCE

MATERIALS OF CONSTRUCTION

Capillary GC Troubleshooting: a Practical Approach

Hydrocarbon Processing Industry Gas Chromatographs. Standard GC Analyzer Solutions

SCION GC Series. The Gas Chromatographers Choice for Separations

SCION GC Series. The Gas Chromatographers Choice for Separations

2014 Chromatography Supplies & Instruments Catalog - Gas Purifiers

APPLICATIONS BENEFITS INTELLIGENT

Agilent Consumables Improve Performance with Shimadzu GC/MS

Gas Generators. Parker Balston

Equipment. Description. Features. Ordering Information. indicating oxygen trap Series 6200

Hydrogen Generators for Fuel Gas

SCION GC Series. The Gas Chromatographers Choice for Separations

PROCESS ANALYZERS FOR PURIFIED BULK GAS QC/QA: ENTERING THE PPT RANGE

Analytical Gas Systems Product Catalog

OXYGEN TRAPS MOISTURE

Markes International Thermal Desorption G8125A, G8126A, G8127A, G8128A, G8131A, G8132A, G8136A, G8133A, MKI-MicroC Site Preparation Checklist

Hydrogen Generators Flow Capacities up to 500 cc/min

Fast Refinery Gas Analysis Using the Agilent 490 Micro GC QUAD

For highest levels of purity

Ultra High Purity Hydrogen Generators

Meet the airgc. Ambient air carrier. Top performance. catalytics accelerated

LD8000. DESIGN REPORT v2. Trace Nitrogen in Argon or Helium analyzer

Varian Supplies/Parts. GC Accessories. Septum Nut. Merlin Microseal Kit

TRACE ANALYTICAL. ta7000 Series UHP Gas Purity Monitors At the critical link in your manufacturing process. Features /Benefits

Hydrogen Generators. Zero Air Generators

Turnkey configurations for gas chromatographic analysis, including instrumentation, methods, supplies and service. Analysis of Natural Gas

Miniature Helium Purifier and Nitrogen Purifier Instruction Manual

ANALYTICAL GAS GENERATORS

MS Certified Vials. Pre-cleaned and certified vials for mass spectrometry

Agilent Gas Phase Solutions

ANALYTICAL GAS GENERATORS INNOVATIVE GAS SOLUTIONS FOR YOUR LAB

STANDARD OPERATING PROCEDURES

Preparation of Reagent Water

Ghost Peaks in Gas Chromatography Part 2: The Injection Port

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Parker N2-04

VWR ANALYTICAL GAS GENERATORS FOR CHROMATOGRAPHY APPLICATIONS

Two Great Technologies Together At Last. The 700 Series NanoTrace Moisture And Oxygen Analyzers

Line filters LINE FILTERS

REVERSE OSMOSIS SYSTEM USER'S MANUAL. Excellent Product, Excellent Water! My PurePro X6

Hamilton PRP Polymeric Columns

INDUSTRIAL AND ULTRA PURE GAS PURIFICATION

Elemental Analysis (EA)

Improved Gas Chromatograph Method for the Analysis of Trace Hydrocarbon Impurities in 1, 3-Butadiene

SPARK TM MOISTURE ANALYZER VALIDATION Performed in Conjunction with Air Products and Chemicals, Inc.

On-Line Gas Analysis In Air Separation Plants

order:

MOSH - MOAH Seminar 27 november Welkom Willkommen Wellcome

Content Page OPTIC Liners OPTIC 2 OPTIC 3 OPTIC-4 LINEX PHASER

TDLAS. Application Note. Tunable Diode Laser Absorption Spectroscopy (TDLAS) for Carbon Dioxide Measurements In Natural Gas Processing

Please enclose a item wise compliance report along with the technical bid.

Measurement of part per billion H2-NMHC-CH4-N2-CO2-CO for semiconductor gases

Optimizing Productivity and Reliability for Monocyclic Aromatic Hydrocarbon Purity Analysis According to ASTM D7504 on the Agilent 8890 GC System

40% savings SS /8" SS nut (20) SS /4" SS nut (20) SS /8" SS front ferrule (20) SS

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

SAFETY AND QUALITY CONTROL

Residual Solvents in medical cannabis analysis using the SRI 8610C FID GC June 2014

PerkinElmer Supplies/Parts. GC Accessories. Autosampler Syringes

Select Al2O3 MAPD : a new Inert Al2O3 column for the trace analysis of polar reactive hydrocarbons.

Mach-RGA. The Fast Refinery Gas Analyzer. Analyzer

Line Filters Solid, simple, smart. Advanced reliability in compressed air. TECHNOLOGY YOU CAN TRUST

Gas Chromatography SSI-GC-003

Prefractionator for Reliable Analysis of the Light Ends of Crude Oil and other Petroleum Fractions

SpeedExtractor E-916 / E-914 Technical data sheet

Gas Generator ULTRA HIGH PURE - HIGH FLOW. Gas Generator

FINAL REPORT. Participants in the reported tasks 1. Ravi Subramanian 2. Manoranjan Misra 3. Kent Hoekman

Heated FID 109A. Rack Mount/Table Top NMGOC Analyzer

PAMS: A Study of Performance in Low and High Humidity Environments

AUTOMATIC PEROXYACETYL NITRATE (PAN) ANALYZER

Passive Monitoring: A Guide to Sorbent Tube Sampling for EPA Method 325. Nicola Watson July 2015

Electron Capture Detector for GC-2010 Plus

The World s Most Versatile Filter System

ON-SITE GAS SOLUTIONS FROM PROTON ONSITE

The CDS 7000 E Purge & Trap Concentrator

Large Valve Oven Analyzers for Refinery Gas Analysis. ASTS 2015 Houston Shannon Coleman Application Specialist Agilent Technologies

( ) IONPAC ATC-HC ANION TRAP COLUMN

PG Series Gaskleen Purifier Assemblies and Manifolds

Avoiding oxygen and moisture contamination in ultra-high purity gases for semi-conductor manufacture

Erstellt mit einer Testversion von PDF Annotator - FLUIDIC & OPTICAL PRODUCTS AND INFORMATION

Agilent MetaCarb 87H Organic Acids Column H + Form User Manual Part No. A5214

March 2016 ARM, Inc. white paper: Safe Approach to Gas Purification. Abstract

BIP technology. setting the standard for Experis high purity gases

Mar Cor Purification. Carbon Block Filtration System. Operation & Maintenance Manual

TVOC Heated FID VE 7

for Acclaim Carbamate Column

Liners and consumables for OPTIC Inlet. Liner Selection Guide

Autosampler Supplies for Agilent GC and HPLC Systems with CTC Autosamplers

Engineering Excellence

GAS CHROMATOGRAPH FOR MULTIPLE IMPURITIES

BIP Technology: the highest purity gases consistently

Pesticide Analysis in a Complex Matrix using a 2D GC/MS System

When optimization is discussed throughout this talk, it s in terms of performing more samples, in less time, while minimizing investment in capital

Laboratory Gas Generators

Inertsil ODS-3 2 µm. Base Silica Physical Properties and Chemical Modification. Base Silica: High Purity Silica Gel % Surface Area: 450 m 2 /g

Transcription:

Super Clean Gas Filters TM Simply the best Cartridge Type rev. 1.4 Features EP-B-0606960 U.S. Patent 5.478.378 Ultra-high capacity High-purity output ensures 99.9999% Pure gas Quick connect fittings for easy, leak-tight cartridge changes Glass inside to prevent diffusion; plastic outside for safety Easy-to-read indicators

Super Clean TM Gas Filters Cartridge systems make changing gas filters quick and easy. A base plate allows cartridges to be exchanged without introducing oxygen. Spring-loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no longer a need for loosening and tightening fittings everytime a trap is changed and your system will not become contaminated during the proces Carrier Gas Purity Carrier gas should contain less than 1ppm of oxygen, moisture, or other trace contaminants, to prevent column degradation, increase column lifetime, and decrease stationary phase bleed. The expense of using high-purity gases in combination with carrier gas line purifiers will be offset by longer column lifetime and less GC maintenance. Contaminants cause ghost peaks to appear during temperature programming and degrade the validity of analytical data. Make-up gas also should be contaminant-free, or baseline fluctuations and excessive detector noise can occur; detector gases should be free of water and hydrocarbons, or excessive baseline noise can result. Gas purifiers remove these contaminants from gas sources, thereby improving system performance. Applications & Configurations Triple Filter Kit for MS/ECD/NPD The Triple Filter Kit is an all in one solution ideal for purifying carrier gas. The includes 1 Triple (Oxygen/Moisture/Hydrocarbon) Filter cartridge and (1) 1 position base plate. Filter Type Part No. Gas Type Triple Filter SGT-F0301 Carrier Gas Kit Part No. SGT-B1010-B8 Complete Filter Bundle Kit for FID The Fuel Gas Triple Kit is perfect for purifying carrier gas and flame ionization detector (FID) fuel gases, removing oxygen, moisture and hydrocarbons from the carrier gas using the triple filter and removing both moisture and hydrocarbons from the Fuel gas using the two combi filters. Using the combi filters for FID Hydrogen and air will produce a stable baseline, improving overall reproducability and sensitivity. Filter Type Part No. Gas Type Triple Filter SGT-F0301 Carrier Gas Combi Filter SGT-F0201 Hydrogen Combi Filter SGT-F0201 Air Kit Part No. SGT-B1030-B8 Page 2

Ultra Filter Bundle Kit for FID Ultra purity combined with Ultra capacity. This contains (1) Ultra High Moisture filter, (1) Ultra High Oxygen Filter, (2) Ultra High Hydrocarbon Filters and (1) four position base plate. Filter Type Part No. Gas Type Moisture Filter SGT-F0101 Carrier Gas Oxygen Filter SGT-F0102 Carrier Gas Hydrocarbon Filter SGT-F0103 Hydrogen Hydrocarbon Filter SGT-F0103 Air Kit Part No. SGT-B1040-B8 Fuel Gas Kit for FID The Fuel Gas Kit Gas is perfect for purifying flame ionization detector (FID) fuel gases, removing both moisture and hydrocarbons. Using the Fuel Gas Filter for FID Hydrogen and air will produce a stable baseline, improving overall reproducability and sensitivity. Filter Type Part No. Gas Type Combi Filter SGT-F0201 Hydrogen Combi Filter SGT-F0201 Air Kit Part No. SGT-B1020-B8 Super Clean TM Gas Filters for GC/MS Ultra-High Moisture Filter SGT-F0101 Inert carrier gas, He, H2, N2, AR, Air Moisture Removal Moisture in carrier gas lines will prematurely degrade oxygen and hydrocarbon traps and increase detector noise. As a precaution, we higly recommend installing a moisture trap before the hydrocarbon and oxygen traps on all carrier gas lines. 7.2 g Page 3

Ultra-High Oxygen Filter SGT-F0102 Inert carrier gas, He, H2, N2, AR Oxygen Removal Oxygen is a column killer. It is present even in UHP gases, as minutes leaks at fittings allow oxygen to influx against the concentration gradient. Because oxygen can enter a gas line at any fitting or during gas bottle exchange, the oxygen trap should be the last connection before the gas line enters the chromatograph. O 2 1000 ml Ultra-High Hydrocarbon Filter SGT-F0103 Inert carrier gas, He, H2, N2, AR, Air Hydrocarbon Removal Use a hydrocarbon trap if your gas has a potential source of hydrocarbon contaminants or if you suspect you are observing carrier gas ghost peaks. Install the hydrocarbon trap after the moisture trap, to prevent moisture from degrading the hydrocarbon-trapping ability of the activated carbon in the hydrocarbon trap. 24 g (as n-butane) Ultra-High Indicating Hydrocarbon Filter SGT-F0104 Inert carrier gas, He, H2, N2, AR, Air Indicating Hydrocarbon The hydrocarbon trap is also available with AT indicator. 24 g (as n-butane) High Combi Filter SGT-F0201 Inert carrier gas, He, H2, N2, AR, Air Fuel Gas Filter The Fuel Gas Filter is perfect for purifying flame ionization detector (FID) fuel gases, removing both moisture and hydrocarbons. Using the Fuel Gas Filter for FID Hydrogen and air will produce a stable baseline, improving overall reproducability and sensitivity. Ideal for use in combination with a zero air generator. 3.5 g 12 g (as n-butane) Page 4

High Triple Filter SGT-F0301 Inert carrier gas, He, H2, N2, AR Triple Filter The Triple trap is ideal for purifying carrier gas. It contains oxygen, moisture and hydrocarbon scrubbers in one easy to change economical cartridge O 2 1.8 g 500 ml 7 g (as n-butane) High Triple Filter with AT Indicator SGT-F0303 Inert carrier gas, He, H2, N2, AR Triple Filter with AT Indicator The Triple trap is also available with AT indicator for Hydrocarbon. O 2 1.8 g 500 ml 7 g (as n-butane) High Triple Filter Helium Specific SGT-F0302 He Triple Filter Helium Specific The Helium-Specific Triple trap is ideal for purifying helium in GC/MS systems. This trap is packed and purged under helium and contains oxygen, moisture and hydrocarbon scrubbers in one cartridge. O 2 1.8 g 500 ml 7 g (as n-butane) High Triple Filter Hydrogen Specific SGT-F0304 H2 Triple Filter Hydrogen Specific The Hydrogen-Specific Triple trap is ideal for purifying hydrogen in GC/ MS systems. This trap is packed and purged under hydrogen and contains oxygen, moisture and hydrocarbon scrubbers in one cartridge. O 2 1.8 g 500 ml 7 g (as n-butane) Page 5

Super Clean TM Gas Filters for LC/MS To meet the high flow needs of the LC/MS system, the hydrocarbon or moisture filled cartridges are positioned and placed in parallel. The incoming gas stream is split equally between the cartridges and the two streams are rejoined after purification but before the gas exits the base plate. Kit Part No. SGT-B1021-B4 Ultra-High Hydrocarbon Filter bundle for LC/MS SGT-F0720 20 L/min. Nitrogen 3 to 6 months Kit Part No. SGT-B1022-B4 Hydrocarbon Removal Up to 20 L/min. of hydrocarbon-free nitrogen per minute. 24 g (as n-butane) Ultra-High Indicating Hydrocarbon Filter bundle for LC/MS SGT-F0722 20 L/min. Nitrogen 3 to 6 months Indicating Hydrocarbon The high flow hydrocarbon trap is also available with AT indicator. 24 g (as n-butane) Ultra-High Moisture Filter bundle for LC/MS SGT-F0721 20 L/min. Inert carrier gas, He, H2, N2, AR, Air 3 to 6 months Moisture Removal High Flow moisture filters are ideal for central purifying solutions. Moisture in carrier gas lines will prematurely degrade oxygen and hydrocarbon traps and increase detector noise. As a precaution, we higly recommend installing a moisture trap before the hydrocarbon and oxygen traps on all carrier gas lines. 7.2 g Page 6

Ordering Information Super Clean TM Filter and Base plate Kits Part No. * Description qty. SGT-B1010-B8 SGT-B1011-B8 SGT-B1012-B8 SGT-B1020-B8 SGT-B1030-B8 SGT-B1040-B8 SGT 1 Triple Filter Kit - 1 / 8 Brass Includes (1) 1 position base plate with 1 / 8 Brass inlet/outlet fittings and (1) Oxygen/Moisture/Hydrocarbon Trap SGT 1 Triple Helium Specific Filter Kit - 1 / 8 Brass Includes (1) 1 position base plate with 1 / 8 Brass inlet/outlet fittings and (1) Oxygen/Moisture/Hydrocarbon Helium Specific Trap SGT 1 Triple Hydrogen Specific Filter Kit - 1 / 8 Brass Includes (1) 1 position base plate with 1 / 8 Brass inlet/outlet fittings and (1) Oxygen/Moisture/Hydrocarbon Hydrogen Specific Trap SGT 2 Combi Filters Kit - 1 / 8 Brass Includes (1) 2 position base plate with 1 / 8 Brass inlet/outlet fittings and (2) Hydrocarbon/Moisture Traps SGT 3 Filters Kit - 1 / 8 Brass Includes (1) 3 position base plate with 1 / 8 Brass inlet/outlet fittings and (1) Oxygen/Moisture/Hydrocarbon Trap and (2) Hydrocarbon/Moisture Traps SGT 4 Filters Kit - 1 / 8 Brass Includes (1) 4 position base plate with 1 / 8 Brass inlet/outlet fittings and (1) Moisture Trap, (1) Oxygen Trap, and (2) Hydrocarbon Traps * Standard fittings are 1 / 8 Brass. All Kits are available in 1 / 4 to 1 / 8 Brass and Stainless steel fittings. To order replace Part No. suffix into -B4 for 1 / 4 Brass, -S8 for 1 / 8 Stainless steel and -S4 for 1 / 4 Stainless steel fittings. Price upon request. Super Clean TM Replacement Filter Bundles SGT-F0730 SGT Filter Bundle of 3 Includes (1) Oxygen/Moisture/Hydrocarbon Trap and (2) Hydrocarbon/ Moisture Traps SGT-F0740 SGT Filter Bundle of 4 Includes (1) Moisture Trap, (1) Oxygen Trap, and (2) Hydrocarbon Traps bundle bundle Super Clean TM Replacement Filters SGT-F0101 SGT Moisture Filter ea. SGT-F0102 SGT Oxygen Filter ea. SGT-F0103 SGT Hydrocarbon Filter ea. SGT-F0104 SGT Hydrocarbon with AT indicator Filter ea. SGT-F0201 SGT Combi (Hydrocarbon/Moisture) Filter ea. SGT-F0301 SGT Triple (Oxygen/Moisture/Hydrocarbon) Filter ea. SGT-F0303 SGT Triple (Oxygen/Moisture/Hydrocarbon) with AT indicator Filter ea. SGT-F0302 SGT Triple (Oxygen/Moisture/Hydrocarbon) Helium-specific Filter ea. SGT-F0304 SGT Triple (Oxygen/Moisture/Hydrocarbon) Hydrogen-specific Filter ea. Super Clean TM Filter Base plates Part No. * Description qty. SGT-B0010-B8 SGT Base plate 1 Position - 1 / 8 Brass ea. SGT-B0020-B8 SGT Base plate 2 Position - 1 / 8 Brass ea. SGT-B0030-B8 SGT Base plate 3 Position - 1 / 8 Brass ea. SGT-B0040-B8 SGT Base plate 4 Position - 1 / 8 Brass ea. * Standard fittings are 1 / 8 Brass. All base plates are available in 1 / 4 to 1 / 8 Brass and Stainless steel fittings. To order replace Part No. suffix into -B4 for 1 / 4 Brass, -S8 for 1 / 8 Stainless steel and -S4 for 1 / 4 Stainless steel fittings. Price upon request. Page 7

Ordering Information Super Clean TM Base plate Flush Cap Replacement Set for GC/MS B0130 Flush Cap Replacement Set 2-pk. Wall mounting Bracket for all Cartridge base plates B0050 Wall-mounting Bracket Set ea. Replacement O-Rings for all Cartridge base plates B0110 Base plate O-ring Replacement Set 20-pk. Super Clean TM Base plate fittings for GC/MS B0120 Connector Set - 1 / 4 Brass 6-pk B0121 Connector Set - 1 / 8 Brass 6-pk B0122 Connector Set - 1 / 4 Stainless steel 6-pk. B0123 Connector Set - 1 / 8 Stainless steel 6-pk. Super Clean TM Filter and Base plate Kits for LC/MS Part No. * Description qty. SGT-B1021-B4 SGT-B1022-B4 SGT High Flow Hydrocarbon Filter Kit - 1 / 4 Brass Includes (1) 2 position high flow base plate with 1 / 4 Brass inlet/outlet fittings, (2) High Flow Hydrocarbon Traps, and a 1 / 4 Brass Particle Filter SGT High Flow Moisture Filter Kit - 1 / 4 Brass Includes (1) 2 position high flow base plate with 1 / 4 Brass inlet/outlet fittings, (2) High Flow Moisture Traps, and a 1 / 4 Brass Particle Filter * Standard fittings are 1 / 4 Brass. All LC/MS Kits are available in 1 / 4 Brass and Stainless steel fittings. To order replace Part No. suffix into -S4 for 1 / 4 Stainless steel fittings. Price upon request. Super Clean TM Replacement Filter Bundles for LC/MS SGT-F0720 SGT-F0722 SGT-F0721 SGT High Flow Hydrocarbon Filter Bundle Includes (2) High Flow Hydrocarbon Traps SGT High Flow Indicating Hydrocarbon Filter Bundle Includes (2) High Flow Indicating Hydrocarbon Traps SGT High Flow Moisture Filter Bundle Includes (2) High Flow Moisture Traps bundle bundle bundle Super Clean TM Base plate for LC/MS Part No. * Description qty. SGT-B0021-B4 SGT High Flow Base plate 2 Position - 1 / 4 Brass Includes 1 / 4 Brass Particle Filter * Standard fittings are 1 / 4 Brass. LC/MS base plate is available in 1 / 4 Brass and Stainless steel fittings. To order replace Part No. suffix into -S4 for 1 / 4 Stainless steel fittings. Price upon request. ea. Page 8

Ordering Information Particle Filter for LC/MS B0060 0.5 Micron Particle Filter ( 1 / 4 Brass) ea. B0065 0.5 Micron Particle Filter Cup Replacement Pack 12-pk. Super Clean TM Base plate fittings for LC/MS B0124 High Flow Connector Set - 1 / 4 Brass 6-pk. B0125 High Flow Connector Set - 1 / 4 Stainless steel 6-pk. Super Clean TM Base plate Flush Cap Replacement Set for LC/MS B0131 High Flow Flush Cap Replacement Set 2-pk. Page 9

Authorised Reseller Scientific Glass Technology Singapore - The Netherlands www.sgt-nl.com Page 10