Schöck Isokorb type CV

Similar documents
Schöck Isokorb type CVB Design

Schöck Isokorb Type CV

Schöck Isokorb Type CM

Schöck Isokorb Type CEQ

Schöck Isokorb type DXT

Schöck Isokorb type D

Schöck Isokorb type K

Schöck Isokorb Structural Thermal Break. Schöck Isokorb Structural Design

Schöck Isokorb type K-HV, K-BH, K-WO, K-WU

Schöck Isokorb type WXT

Schöck Isokorb type W

Schöck Isokorb type OXT

Schöck Isokorb type KS

Schöck Isokorb Structural Thermal Break. Schöck Isokorb Structural Design

COLUMNS 1- Definition: The Egyptian code defines columns as : 2- Types of concrete columns

Product Information Bulletin

Seismic Behaviour of RC Shear Walls

The Art of Construction and The Design. Direct, rebar chair.

Proposed Revisions to Part 2, Sections 2.13 to Draft DEVELOPMENT AND SPLICES OF REINFORCEMENT SECTION 2.13 DEVELOPMENT REQUIREMENTS

R-Group Finland Oy. RLA Lifting Inserts Technical Manual According to Eurocodes, EU Machinery directive 2006/42/EC and VDI/BV-BS 6205 CE Approved

TECHNICAL MANUAL. PVL Connecting Loop. Wall Connecting Loop Box with Single Wire

EXPERIMENTAL INVESTIGATION ON SEISMIC BEHAVIOUR OF KNEE JOINTS IN REINFORCED CONCRETE FRAMES

Thermal Bridge Solutions. Schöck Isokorb Product Guide. North America

HILTI HY 150 REBAR DESIGN GUIDE

Masonry and Cold-Formed Steel Requirements

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES REPORT HOLDER: HALFEN GMBH

Fire Behaviour of Steel and Composite Floor Systems Worked examples

Chapter 2 Notation and Terminology

1 Prepared By:Mr.A.Sathiyamoorthy, M.E., AP/Civil

ST7008 PRESTRESSED CONCRETE

CHAPTER 10: GENERAL STRUCTURAL DETAILS

LIGHT-GAUGE PANELIZED WALL SYSTEMS. Michael Waggoner Mark Schroeder

Case Study. Schöck chosen for major Passivhaus residential scheme

Sabah Shawkat Cabinet of Structural Engineering 2017

ALLOWABLE STRESS DESIGN OF CONCRETE MASONRY LINTELS. TEK 17-1C Structural (2009) Related TEK: Uniform load. Triangular load. Concentrated loads

CONNECTOR B L O C K S H E A R. Design for Composite Structural Action BLOCK SHEAR CONNECTOR APPLICATION. Airspace

Experimental study on the seismic performance of RC moment resisting frames with precast-prestressed floor units.

Interaction between ductile RC perimeter frames and floor slabs containing precast units

Danielle Shetler - Structural option Courtyard by Marriott Lancaster, PA

Supplemental Plan Check List for Concrete Special Moment Resisting Frame

Joint Design of Precast Concrete Moment Frame using Hollow Precast Concrete Column Soo-Yeon Seo, Tae-Wan Kim, Jong-Wook Lim, Jae-Yup Kim

International Journal of Advance Engineering and Research Development REVISION OF IS: A REVIEW (PART 2)

ANNEX 10. Special requirements recommended for structures subject to seismic actions. 1 Scope. 2 Basis of design. 2.1 Fundamental requirements

Calculation of Wind Loads on Structures according to ASCE 7-10

Special Reinforced Concrete Structural Walls

Structural Calculations for standard BALCONY 1 system handrail using 55mm diameter posts (48.3mm x 5mm CHS) & 150 x 150 x 15mm base plates

APPENDIX B ABC STRUCTURES DESIGN GUIDE

RUUKKI FAÇADE SYSTEMS

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures

Modelling of RC moment resisting frames with precast-prestressed flooring system

mortarless Design Manual Part 3 (AS 3600:2009) Section 2 Page: DESIGN OF WALLS FOR AXIAL COMPRESSION USING SIMPLIFIED DESIGN METHOD

Sabah Shawkat Cabinet of Structural Engineering 2017

Acknowledgments. Abstract

SECTION 10. DESIGN FOR SHEAR

10-COLUMNS: 10.1 Introduction.

Supplemental Plan Check List for Concrete Special Moment Resisting Frame

Seismic response of a cast-in-place steel fibre concrete joint connecting precast beams and columns

EN REINFORCED MASONRY DESIGN EXAMPLE 1 (NOTE: THIS USES THE UK NATIONAL ANNEX NDP VALUES)

The nominal cover can be assessed as follows: C nom

Lecture Retaining Wall Week 12

XHBN.FF-D Joint Systems. Joint Systems. System No. FF-D-3008

DESIGN FOR PROGRESSIVE COLLAPSE 1

ROOT VEGETABLE STORAGE WAREHOUSES

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code

Acknowledgments. Abstract

CHAPTER 2. Design Formulae for Bending

BubbleDeck Design Guide. The two-way hollow deck. The way to new solutions

Types of Foundations

> 0. 1 f, they are treated as beam-columns.

COLUMNS. Classification of columns:

Footings GENERAL CONSIDERATIONS 15.2 LOADS AND REACTIONS 15.4 MOMENT IN FOOTINGS

Product overview:

TECHNICAL MANUAL. PC Beam Shoe. Hidden Beam Shoe for Corbel System

3.4.2 DESIGN CONSIDERATIONS

VALLIAMMAI ENGINEERING COLLEGE

Seismic Detailing of RC Structures (IS: )

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

Sabah Shawkat Cabinet of Structural Engineering 2017

Agricultural Hall and Annex East Lansing, MI. Structural Design. Gravity Loads. 1- Based on US Standards

PC Beam Shoe. Corbel system to support beams. Technical Manual. Version: DK 4/2012 Design standard: DS EN Eurocodes + NA (Denmark)

Seismic Design of Ductile Shear Walls

CONNECTOR S T U D S H E A R. Design for Composite Structural Action STUD SHEAR CONNECTOR APPLICATION

STRUCTURAL CALCULATIONS

4.6 Procedures for Connections

CE2306 DESIGN OF RC ELEMENTS UNIT II LIMIT STATE DESIGN FOR FLEXTURE Part A (2marks) 1. Explain the check for deflection control in the design of

ISSUE A Code Change # 2 Class 3 and Class 4 Buildings

CHAPTER 9 STAIR CASES 9.1 GENERAL FEATURES 9.2 TYPES OF STAIR CASES

BS EN :2004 EN :2004 (E)

A Study on the Effect of Shear Connectors in Composite Beams

DESIGN OF WALLS FOR SHEAR

RUUKKI FORMA DESIGN INSTRUCTION

Council on Tall Buildings

Diagonal Ties Connectors for precast concrete sandwich panels. Version: AE, SA 08/2018. Technical Manual

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Double Insulation The new Schöck Isokorb KXT

7. SPECIFIC RULES FOR STEEL CONCRETE COMPOSITE BUILDINGS

CUREe-Kajima Flat Plate 1 Kang/Wallace

STRUCTURAL CALCULATIONS

DATA SHEET 3 Concrete Masonry Lintels MARCH 2013

Transcription:

Schöck Isokorb type The Schöck Isokorb type is suitable for supported reinforced concrete slabs. (C concrete slab) It transmits positive shear force (vertical shear). 71

72

Section/element arrangement Schöck Isokorb type, supported balcony with window wall systems Position of Schöck Isokorb type Schöck Isokorb type, supported balcony, steel studs, facing shell and insulation layer in between The Schöck Isokorb type should be located in the insulating layer. Orientation of the Schöck Isokorb type Attention: the Schöck Isokorb type does not have a symmetrical design. The lower distance between the shear force bars and the insulating element at the bottom edge is always 40 mm. The upper distance can vary. Pay attention to installation orientation and show a cross-section view on the design drawings. The Schöck Isokorb type has the same design at the balcony side and the interior slab side. Element arrangement CEQ Type Type Schöck Isokorb type, balcony supported without planned horizontal load or earthquake load. Schöck Isokorb type, balcony supported with planned horizontal load or earthquake load. Note: For designed horizontal loads and earthquake loads, the Schöck Isokorb CEQ module must be used. With horizontal tensile forces at right angles to the outside wall greater than the existing shear force, the Schöck Isokorb CEQ module must also be used. 73

Slab geometry/span length/expansion joints Recommended maximum span length The maximum span length results from the factored shear force V f. Span length for the structural calculations The support of the balcony is assumed to be 100 mm from the Schöck Isokorb insulating element at the interior slab side. Expansion joints (recommended balcony length) The expansion joint spacing shown below corresponds to a temperature difference of T = 70 C. h H l CC 100 5.29 10.58 5.29 Type Type Schöck Dorn ESD-K Expansion joint Type Type Type 5.29 l Schöck Isokorb type, expansion joint arrangement Note: The maximum expansion joint spacing must be verified by the EOR. The spacing of the pressure elements from the free edge of the expansion joint must be at least 50 mm, and the spacing of the shear force bars must be at least 100 mm and no more than 150 mm. The expansion joint must be free to deform in the longitudinal direction, for which we recommend the A4 stainless steel Schöck Dorn ESD-K, for example. 74

Concrete cover/type designation Concrete cover CC The concrete cover of the Schöck Isokorb type is set to 40 mm (CC40) from below. The concrete cover is always greater than 40 mm if the minimum slab thickness is complied with. H h min 40 40 l 80 100 Concrete cover without sloping balcony slab Minimum slab thickness The following minimum slab thicknesses h min must be complied with depending on the load capacity. Schöck Isokorb type 10 20 30 Minimum slab height h min [mm] 180 180 180 Type designation in design drawings The following type designation specifies the Schöck Isokorb type that is required. The type designation is indicated on design drawings. The type designation is printed on the sticker of the Schöck Isokorb type as a recognition feature. Ultimate (factored) shear resistance, V r [kn/m] Isokorb height H [mm] Schöck Isokorb type 10 20 Concrete covering CC40 [mm] Concrete strength 180-210 40.8 54.4 220 38.4 51.2 230 33.3 44.4 240 29.4 39.2 250 26.3 35.1 Slab thickness h min [mm] 180 180 Type designation in design drawings 447 80 447 with fire protection 20-CC40-H200-R120 40 Type/load capacity Concrete cover Isokorb height Fire protection 40 CC40 200 H200 75

Product cross-section 347 80 347 340 340 40 180-250 45 Product cross-section of Schöck Isokorb type 10 and 20 447 80 447 40 40 180-250 Product cross-section of Schöck Isokorb type 30 Schöck Isokorb length and configuration Schöck Isokorb type 10 20 30 Isokorb length [m] 1.0 1.0 1.0 Isokorb height [mm] 180-250 180-250 180-250 Shear force bars 6 ø 6+6 ø 6 8 ø 6 + 8 ø 6 6 ø 8+6 ø 8 Pressure bearings (pcs.) 4 4 4 Note: The product cross-sections of load capacities 10 and 20 of the Schöck Isokorb type are identical. The Schöck Isokorb type may be split at the non-reinforced locations. The spacing of the pressure elements from the free edge of the reinforced concrete slab must be at least 50 mm, and the spacing of the shear force bars must be at least 100 mm and no more than 150 mm. 76

Overhead view of product 50 200 200 100 200 200 50 100 300 200 300 100 50 100 200 100 100 100 200 100 50 100 300 200 300 100 347 (340) 80 340 (347) 347 (340) 80 340 (347) Overhead view of Schöck Isokorb type 10 Overhead view of Schöck Isokorb type 20 50 100 200 100 100 100 200 100 50 100 300 200 300 100 447 80 447 Overhead view of Schöck Isokorb type 30 77

Design The support is assumed to be 100 mm from the Schöck Isokorb insulating element at the interior slab side. h min l CC H 100 Product selection table as per CSA A23.3-04 Ultimate (factored) shear resistance, V r [kn/m] Isokorb height H [mm] Schöck Isokorb type 10 20 30 Concrete covering CC40 [mm] Concrete strength 30 MPa 180-210 40.8 54.4 72.5 220 38.4 51.2 72.5 230 33.3 44.4 72.5 240 29.4 39.2 69.2 250 26.3 35.1 61.9 Slab thickness h min [mm] 180 180 180 Notes With different balcony slab and floor slab concrete qualities, the weaker concrete should be used with the tables above. The shear capacity of the slabs must be verified by the EOR. Because of the eccentric connection, a moment occurs at the slab edges at both sides of the Schöck Isokorb type. The transmission of this moment in the two connecting slabs must be verified in each individual case. Verification for the slabs attached at both sides of the Schöck Isokorb must be submitted by the EOR. When the reinforcement of the floor slab and the balcony slab which connect to the Schöck Isokorb type is being determined, it must be assumed that there is a hinge, since the Schöck Isokorb type can only transmit shear force. For seismic loads the Schöck Isokorb CM has to be combined with the Schöck Isokorb type CEQ. The capacities are considering the maximum permitted bar separation according CSA A23.3-04 Cl 12.14.2.3, based on the same height of the slab and Isokorb and a concrete cover of the interior slab of 20mm. For differing boundary conditions the capacities have to be checked. 78

Moments from eccentric connection Deformation An estimate of the additional deformation from the Schöck Isokorb type was made on the basis of component testing. In the tests, the bearing points or bearing edges were subjected to vertical deformation of approx. 0.8 to 1.0 mm. Moments from eccentric connection In order to determine the connecting reinforcement at both sides of the Schöck Isokorb type, moments from an eccentric connection must also be taken into consideration. Each of these moments must be overlaid with the moments from the planned load, providing that they act in the same direction. V f V f Δ M ecc, f 1/2 ev V f V f V f 1/2 ev Δ M ecc, f V f ΔM ecc, f = V f 1/2 e V Schöck Isokorb length and configuration Schöck Isokorb type 10 20 30 Δ M ecc,f 1) [knm/m] 1.8 2.4 3.4 Note: These recommendations must be checked by the EOR and modified if necessary. 1) with max e v = 140 mm 79

Cast-in-place reinforcement The cast-in-place reinforcement is defined by the EOR of the building in accordance with structural requirements. The shear force bars of the Schöck Isokorb type must be overlapped with the tensile reinforcement (Pos. 1). Positions 2 (longitudinal edge reinforcement),pos. 3 (U-Bars) and Pos. 4 (U-Bars for the free balcony edge) must also be provided. The following is a suggestion for the reinforcement layout. Cross-section f'c 30 MPA Pos. 1 A Pos. 2 Pos. 2 Pos. 1 f'c 30 MPA Interior Slab Pos. 6 Pos. 3 Pos. 3 Pos. 6 Pos. 5 Upper balcony reinforcement (EOR) A Pos. 1 Upper slab reinforcement (EOR) Pos. 5 Pos. 6 Pos. 6 410 (min) Pos. 3 Pos. 2 Pos. 3 410 (min) Pos. 6 Pos. 6 Lower balcony reinforcement (EOR) Pos. 5 Lower slab reinforcement (EOR) Cross section of recommended cast-in-place reinforcement (supplied by building contractor) Section A-A (Free edge) Shear force bars, Isokorb Pressure bearings, Isokorb Pos. 1 Plan View Interior Slab Pos. 6 A A type Pos. 4 Pos. 3 Pos. 5 Upper reinforcement (EOR) Pos. 1 Pos. 4 Pos. 6 Lower reinforcement (EOR) Pos. 5 Section A-A Depiction of free balcony edge 80

Cast-in-place reinforcement, indirect support Suggestion for cast-in-place connective reinforcement For 100% section strength with a minimum concrete strength of 30MPa. The existing slab reinforcement can be taken into account for the required reinforcement of connections with Schöck Isokorb. Schöck Isokorb type 10 20 30 Pos 1: Overlapping reinforcement upper layer Required cross-section area a s [mm² / 1.0 m width] In accordance with EOR specifications Pos 2: Longitudinal edge Reinforcement Alternative 1 4 x 10M 4 x 10M 4 x 10M Alternative 2 4 x 15M 4 x 15M 4 x 15M Pos 3: U-Bars for the slab edges Alternative 1 10M @ 250mm 10M @ 250mm 10M @ 250mm Alternative 2 15M @ 350mm 15M @ 350mm 15M @ 350mm Pos 4: U-bars for the free balcony edge Required cross-section area a v [mm² / 1.0 m width] In accordance with EOR specifications Pos 5: Reinforcement bottom layer Required cross-section area a s [mm² / 1.0 m width] In accordance with EOR specifications Pos 6: Longitudinal reinforcement Required cross-section area as [mm² / 1.0 m width] In accordance with EOR specifications Notes: Pos. 4 should be chosen such that the link can be arranged between the legs of pos. 3. The upper and lower reinforcement of the connecting slabs must run as close as possible to the thermal insulation layer at both sides of the Schöck Isokorb, taking the required concrete cover into consideration. All free edges must be bordered using structural U-bars as per EOR specifications.. The centerline distance of any tension or shear bar from any free concrete edge, including expansion joints, must be at least 50 mm. The centerline distance of any pressure element from any free concrete edge, including expansion joints, must be at least 50 mm. The shear force reinforcement must be spliced to the tensile reinforcement in the slab to be connected. In cases in which shear force bars and pressure elements are not laid in one layer, the anchoring length for shear force bars must be determined in the compression zone in the same way as it is for for tension bars. The lap splice length provided by Schöck Isokorb = the length of the tension bar from the face of the Isokorb to the free end - Concrete Cover (CC) 81

Checklist ~ Has the Schöck Isokorb type that is suitable for the structural system been chosen? Type is considered to be a shear force connection only (hinge joint). ~ Has the system span length (i.e., "l") been used for the design? ~ Have the factored member forces at the Schöck Isokorb connection been determined at design level? Do the member forces at the Schöck Isokorb connection include the effects of eccentricity of the connection? ~ Has the critical concrete strength been taken into consideration in the choice of design table? ~ Have both slabs adjacent to the Isokorb been verified for bending and shear capacities by the EOR? ~ Have the requirements with regard to fire re protection been determined, and has the relevant suffix (-R90 or R120) been added to the Isokorb type designation in the design drawings? ~ Has the maximum permissible expansion gap spacing been taken into consideration for the specific slab configuration? ~ Have the horizontal loads such as those from earthquakes been taken into consideration? Additional EQ modules may be required. ~ Has the connecting reinforcement in the balcony and interior slabs been defined by the EOR? ~ When using type and fully prefabricated parts, has the cast-in-place strip of concrete (width 50 mm from pressure bearing elements) that is required to create the tight fit of the HTE pressure bearing been included in the design drawings? 82