Zoning Supporting Design of Deep Foundation Pit Based on Controlling Deformation of Surrounding Buildings

Similar documents
Three-dimensional computer simulation of soil nailing support in deep foundation pit

The Dynamic Characteristic Experimental Method on the Composite Foundation with Rigid-Flexible Compound Piles *

Dynamic Characteristics on Composite Foundation with CFG Pile

The Experimental Study on the Dynamic Characteristics and Attenuation Law of the Composite Foundation

EFFECT OF DEEP EXCAVATION SUPPORTED BY CONCRETE SOLIDER PILE WITH STEEL SHEET PILE LAGGING WALL ON ADJACENT EXISTING BUILDINGS

Deformation monitoring and analysis of deep foundation pit of Xiaoshan rainbow Boulevard

Research on the Effects of Foundation Excavation by the Environment

[Kouravand Bardpareh* et al., 5(6): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

The Application of Foundation Pit Monitoring Technology to the Excavation

Analysis of Retaining Structure of Deep Foundation Pit in Soft Soil Stabilization of Pumping Station * Yanming Chen and Wei Wu

UNDERPINNING A CRANE FOUNDATION

General Behavior of Braced Excavation in Bukit Timah Granite Residual Soils: a Case Study

Advances in Engineering Research (AER), volume Global Conference on Mechanics and Civil Engineering (GCMCE 2017)

Case Histories in Geotechnical Engineering

Nonlinear Analysis and Design of a Guyed Mast: Comparison of Two Design Proposals

EXCAVATION WITHOUT INTERNAL SUPPORT AND ITS IMPLICATIONS IN CONSTRUCTION MANAGEMENT: A CASE STUDY

Environmental vibration resonances of precise bearing platform built on soft soils

Analyzing and Investigating the Effect of Nailing on Stabilization Soil Trenches of Sand with Medium Density via Analytical Limit Equilibrium

LONG-TERM MONITORING AND SAFETY EVALUATION OF A METRO STATION DURING DEEP EXCAVATION

Analysis and Prediction of Foundation Settlement of High-Rise Buildings under Complex Geological Conditions

Numerical Analysis of the Durability of Retaining Wall with Anchor

AVOIDING EXCESSIVE DISPLACEMENTS: A NEW DESIGN APPROACH FOR RETAINING WALLS

Safety Assessment of Excavation with Fault Tree Analysis

DISPLACEMENT OF DIAPHRAGM WALL FOR VERY DEEP BASEMENT EXCAVATION IN SOFT BANGKOK CLAY

Research on single hole heat transfer power of ground source heat pump system

Numerical Simulation of Liquefaction Deformation of Sand Layer around Bucket Foundations under Dynamic Loadings

Journal of Engineering Science and Technology Review 7 (2) (2014) Research Article

Evaluation of negative skin friction on sheet pile walls at the Rio Grande dry dock, Brazil

Design and Finite Element Analysis of A Spatial Tubular Truss and Its Pin Support

Influence of unloading soil modulus on horizontal deformation of diaphragm wall

DEEP BASEMENT EXCAVATION IN SOFT BANGKOK CLAY CLOSED TO PALACES

Dynamic Characteristics Analysis of Large Self-anchored Suspension Bridge

Modeling of Buried Pipe Deformations

Issues on Design of Piled Raft Foundation

Use of Concrete Cross Walls to Reduce Movements Induced by Deep Excavation

Journal of Engineering Science and Technology Review 7 (4) (2014) Experimental Study on Shear Performance of Bolt in Roadway Supporting

Numerical Simulation Analysis of the Stability of Heishan Tunnel s Surrounding Loess during Construction1

Construction Simulation and Analysis on the Prestress of Suspend-dome structures

Load Transferring Mechanism and Design Method of Effective Detailings for Steel Tube-Core Concrete Interaction in CFT Columns with Large-Section

Behavior of Surrounding Soil during Construction and Its Countermeasures Using Pipe Jacking Method in Deep Strata

Foundation pit support and construction of Luneng Real Estate S-20 commercial building

Case study on a deep excavation in Baku: Flame Towers project earth retaining system

Application of Progressive Collapse Analysis in a High-Rise Frame-Core Tube Structure

BEARING CAPACITY IMPROVEMENT USING MICROPILES A CASE STUDY

Jinfeng Zhang 1, Wangsheng Liu 1, Ming Zhao 1 1. College of Civil Engineering, Tongji University, Shanghai , China.

Behaviour of Strip Footing on Geogrid Reinforced Slope subjected to Eccentric Load

Effect of Oval Shape Tunnel on Existing Buildings Under Seismic Loading

Structural Performance Assessment and Control of Super Tall Buildings During Construction

Response of Piered Retaining Walls to Lateral Soil Movement Based on Numerical Modeling

Ecological Study of Moisture Content of Clay Soil Affecting Compressive Failure of the CEP Pile

THREE-DIMENSIONAL NUMERICAL ANALYSIS ON EXCAVATION AND SUPPORT OF DEEP PIT NEAR THE SUBWAY TUNNEL BY COMPUTER SIMULATION TECHNIQUE

Analysis of the Sensitivity of Influencing Factors on Tunnel Secondary Lining Structure *

The New Incremental Launching Construction Technology of Jiubao Bridge Long-span Hybrid Arch-girder Structure

Finite Element Simulation of Molding Process of Cold Bending Pipe

Design of Support System for Excavation in Black Cotton Soils in Guntur, India

Journal of Engineering Science and Technology Review 9 (5) (2016) Research Article. Received 21 July 2015; Accepted 2 November 2016

FEM Analysis of Composite Soil Nailed Wall on the Dynamic Response of Earthquake ZHU Yanpeng, XIE Qiang, DONG Jianhua

The construction of deep excavation ditch in weak soil in St. Petersburg

Testing of ground anchorages for a deep excavation retaining system in Bucharest

Laboratory Study on Sludge Treatment by Electro-Osmosis Combined with Pile-Loading

Numerical Simulation of Soil Nailing Wall in Deep Foundation Pit

ANALYSIS OF INFLUENCE FACTORS FOR EARTHQUAKE-INDUCED DIFFERENTIAL SETTLEMENT OF BUILDINGS

Full-Ring Experimental Study of the Lining Structure of Shanghai Changjiang Tunnel

PARAMETRIC STUDIES OF BOX CULVERTS

Journal of Chemical and Pharmaceutical Research, 2013, 5(9): Research Article. Stability analysis of cantilever retaining wall with FEM

Downloaded from Downloaded from /1

TEST STUDY ON BASIC STATIC CHARACTERISTICS OF CABLE SUPPORTED BARREL VAULT STRUCTURE

Relationship between twin tunnels distance and surface subsidence in soft ground of Tabriz Metro - Iran

Estimation of Lateral Earth Pressure on Cantilever Sheet Pile using Flat Dilatometer Test (DMT) Data: Numerical Study

ctbuh.org/papers Relationship between Natural Vibration Periods and Structural Heights for High-rise Buildings in China Title:

FINITE ELEMENT ANALYSIS OF DEEP BASEMENT CONSTRUCTION OF BANK OF THAILAND ALONG CHAO PHRAYA RIVER CLOSED TO HISTORICAL PALACES

Load sharing characteristics of piled raft foundation in clay soil

Behaviour of Raft Foundation with Vertical Skirt Using Plaxis 2d

Finite Element Analysis of Flexible Anchored Sheet Pile Walls: Effect of Mode of Construction and Dewatering Naveen Kumar 1, Arindam Dey 2*

Behavior of pile due to combined loading with lateral soil movement

Finite element analysis of tunnel soil building interaction using displacement controlled model

3-D finite element analysis on shear lag effect of curved box girder under multi-dimensional seismic excitation

Numerical Analysis of the Bearing Capacity of Strip Footing on Reinforced Soil Slope

Geotechnical Engineering Software GEO5

The use of flexible flaps in improving the settlement resistent behaviour of raft foundations

Sheeting Wall Analysis by the Method of Dependent Pressures

Rong He School of Civil Engineering and Communication, North China University of Water Resources and Electric Power, Zhengzhou, , China

Analysis for Failure Mechanism of Temporary Shoring Structure

Anti-fatigue Performance Analysis on Steel Crane Beam

Nonlinear Seismic Response Analysis for Hong Kong-Zhuhai-Macau Bridge

POSTER PAPER PROCEEDINGS

Prediction of Surface Subsidence Caused by Rectangular Pipe Jacking Construction

Effect of Cavities on the Behaviour of Strip Footing Subjected to Inclined Load

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE CORE WALL

PILE DESIGN METHOD FOR IMPROVED GROUND USING THE VACUUM CONSOLIDATION METHOD

THE EFFECT OF AXIAL COMPRESSION RATIO ON SEISMIC BEHAVIOR OF INFILLED REINFORCED CONCRETE FRAMES WITH PROFILED STEEL SHEET BRACING

Challenges of quick clay excavation in urban area with sloping ground

Soldier pile and tremied concrete walls with strut supports (SI units)

Risk Management of the Restoration of Shanghai Metro Line 4

Title Anchor Head Itself Being Broken. Symposium on Backwards Problem in G.

Structural Design of Super High Rise Buildings in High Seismic Intensity Area

IGC. 50 th. 50 th INDIAN GEOTECHNICAL CONFERENCE INFLUENCE OF TUNNELING ON AN EXISTING PILE FOUNDATION

An Indian Journal FULL PAPER. Trade Science Inc. Application of composite soil nailing support for the deep excavation based on FLAC 3D ABSTRACT

Partial factors: where to apply them?

Study on Shear Lag Effect of Composite Box Girder Bridge with Corrugated Steel Webs

Transcription:

International Journal of Architecture, Arts and Applications 2017; 3(5): 73-78 http://www.sciencepublishinggroup.com/j/ijaaa doi: 10.11648/j.ijaaa.20170305.12 ISSN: 2472-1107 (Print); ISSN: 2472-1131 (Online) Zoning Supporting Design of Deep Foundation Pit Based on Controlling Deformation of Surrounding Buildings Ding Jihui 1, Shen Yu 2, Li Taotao 1, Wang Yan 3, Zhao Tuo 4, Wang Weiyu 4 1 Department of Civil Engineering, College of Civil Engineering and Architecture, Hebei University, Baoding, China 2 Supervision Office, Shanghai Electronics Industry School, Minhang District, Shanghai, China 3 Emergency Command and Dispatch Center, Tanshan Communication Bureau, Tangshan, China 4 Foundation Research Institute, Heibei Academy of Building Research, Shijiazhuang, China Email address: dingjihui@126.com (Ding Jihui), Shenyu6@163.com (Shen Yu), 1654759751@qq.com (Li Taotao), Wangy78@163.com (Wang Yan), monkey856@126.com (Zhao Tuo), weiyu_w@163.com (Wang Weiyu) To cite this article: Ding Jihui, Shen Yu, Li Taotao, Wang Yan, Zhao Tuo, Wang Weiyu. Zoning Supporting Design of Deep Foundation Pit Based on Controlling Deformation of Surrounding Buildings. International Journal of Architecture, Arts and Applications. Vol. 3, No. 5, 2017, pp. 73-78. doi: 10.11648/j.ijaaa.20170305.12 Received: September 19, 2017; Accepted: October 28, 2017; Published: November 23, 2017 Abstract: According to the deep foundation pit of a spatial dimension in Shijiazhuang, the retaining and protection structure of pile and anchor cable is selected because of property of the soil layer. The interaction between the support system and the surrounding buildings is analyzed by the finite difference method, on this basis, according to the deformation of surrounding environment and the stability requirement of slope, the deep foundation pit is made zoning supporting design. When there is a building on the outside of foundation pit wall and the building is located in the middle side of the slope wall, the effect of building on horizontal displacement of foundation pit is mainly happened in the middle of the slope wall, and the range is (0.22~0.78) L (L is the length of the foundation pit) or 1.85A (A is the length of the building along the direction of the pit). The settlement and different settlement of the building foundation can be controlled by increasing the stiffness of the retaining structure, such as increasing the diameter of pile or reducing the spacing of pile. When reducing the diameter of pile or increasing the spacing between the piles in the west side of the slope, the deformation and different deformation of the area are obviously reduced, so as to meet the requirements for the deformation of the underground pipelines outside the slope wall. Keywords: Deep Foundation Pit, Adjacent Building, Pile Anchor Cable Support System, Zoning Supporting Design 1. Introduction Deep foundation pit is a spatial system with dimension in the plane and depth, and its force in stress and deformation has obvious spatial effect. Fook-Hou Lee etc. [1] had monitored and numerically simulated the deep foundation pit of a soft soil layer in Singapore. The results show that the spatial numerical analysis is more valuable than the slope deformation obtained by plane numerical analysis. The size of the length of the foundation pit, the ratio of the length of the short edge and the rigidity of the retaining structure affect the deformation of the foundation pit. Ding Jihui, Yuan Man, Zhang Qin etc. [2, 3, 4] put forward the concept of efficiency factor of earth pressure, the spatial distribution of deformation and internal force on the cantilever retaining structure of deep foundation pitwere analyzed, and discussed the spatial effects of the two-row-pile retaining structure of deep foundation by the utilization factor of earth pressure. Ding Jihui, Fan Fei etc. [5] pointed out that spatial effect was significantly reflected in the deformation, earth pressure and other aspects though the field monitoring results. Wang Weiyu and Ding Jihui etc. [6, 7] analyzed the interaction between the supporting system of the foundation pit and the surrounding building by the finite difference method. Clough and O Rourke [8] found that the surface settlement of hard clay and sand decreases with the distance from the retaining structure and given the deformation areas. Sighs and Ou [9] were divided the influence area of the surface settlement of the retaining structure outside the foundation pit into the major influence area and the minor

74 Ding Jihui et al.: Zoning Supporting Design of Deep Foundation Pit Based on Controlling Deformation of Surrounding Buildings settlement area, and given the range of the surface settlement outside wall of the foundation pit and the vertical displacement of the ground surface. According to the deep foundation pit of a spatial dimension in Shijiazhuang, the retaining and protection structure of pile and anchor cable is selected. The finite difference method is used to analyze the interaction between the supporting system of foundation pit and the surrounding buildings. On this basis, the sectionalized design is carried out, and the zoning design method of deep foundation pit is put forward. distance between the building and the foundation wall is C, and the distance from the south wall is D. The distribution and main parameters of a section soil layer, the design parameters of support system are seen reference [7]. 2. The Thought of Zoning Design in Foundation Pit (1) Analyze the influence of excavation on surrounding environment The unloading of deep foundation pit will inevitably change the stress field and displacement field of surrounding soil. In the end, it may cause passive deformation of adjacent Foundations which will affect the normal use of existing structures. Analyze the scope and strength of influence on foundation pit, which is from surrounding buildings or structures, increase the stiffness of the support structure or select supporting structure form with relatively large stiffness. (2) Standard for deformation of adjacent buildings The environmental impact caused by unloading of foundation pit excavation is inevitable, but the excavation must ensure the safety of the surrounding buildings. The controlling standard for deformation of the surrounding buildings is the key to the design of retaining structures. The additional deformation of the building caused by the excavation of the foundation pit shall be satisfied: ( + ) 2 0 1 3 ξ ξ ξ ξ where, ξ0 is the allowable value for foundation deformation of building; ξ 1 is the existing deformation value of a building; ξ2 is the controlling deformation of foundation based on the excavation of foundation pit; ξ3 is deformation value of foundation in later stage of building(minimum value is 0). The allowable and maximal deformation ξ 0 of different buildings can be chosen from the current specification [10]. The controlling deformation of excavations and adjacent underground pipeline can be chosen from the current specification [11]. Referent values for controlling deformation of foundation pit can be chosen from the current specification [12]. 3. General Situation of Engineering As shown in Figure 1, there is a five-story building in the form of brick-concrete structure around the east side of the foundation pit. The load on each floor is considered as 15kPa, and the total load is 75kPa. The buried depth of the residential building is 1.5m, the length A is 40m, and the width B is 20m. The excavation depth of deep foundation pit H is 10.0m, the Figure 1. Floor plan of foundation pit [7]. 4. The Zoning Design Scheme of the Deep Foundation Pit There are three situations in the surrounding environment of deep foundation pit: (1) There is a building near the slope of the east side, and the distance from the slope is C=0.5H. (2) There is an underground pipeline around the slope of the west side. (3) The south side and the north side are the short side of the foundation pit, where no special protection against the surrounding environment is required, and the support scheme is used. According to the current standard [9-11], combining with the depth of soil layer, ground water, foundation pit, surrounding pipelines and buildings, the alarm values of foundation pit during monitoring are determined. The controlling value of the horizontal displacement is 20.0mm, the top vertical displacement is 10.0mm, the deep horizontal displacement is 30.0mm, the vertical displacement of building is 15mm, the vertical displacement of pipeline is 10mm, the controlling value of different settlement of pipeline and building is 2/1000. 4.1. Deformation Analysis of Slope Wall on East Side When there is building on the outside of foundation pit wall and the building is located the middle side of the slope wall, the effect of building on slope horizontal displacement of foundation pit is mainly happened in the middle of the slope wall, and the range is (0.22~0.78)L (A is the length of the foundation pit) or 1.85A (A is the length of the building). In order to ensure the normal use of the building around the foundation pit, it is necessary to reduce the deformation of the middle slope wall and increase the strength of the supporting structure in the middle part, that is, increasing the diameter of pile or reducing the spacing of pile in the slope whose range is

International Journal of Architecture, Arts and Applications 2017; 3(5): 73-78 75 1.85A (that is 70m). (1) Influence of pile spacing on deformation In the middle east slope wall part of the range of 70m, when the pile spacing is 2.0m, 1.8m, 1.6m, 1.4m, the horizontal displacement of the foundation pit is obtained through the simulation (as shown in Figure 2). pit significantly is reduced with pile spacing decreased. When the spacing of the piles is reduced from 2m to 1.4m, the maximal horizontal displacement is reduced from 24.774mm to 18.986mm. When the pile spacing is changed to 1.4m, the maximal horizontal displacement of the slope wall is less than 20mm, and the design requirements can be meet. Figure 5. When l=1.4m, horizontal displacement map. Figure 2. The horizontal displacement of the east slope with different pile spacing. Figure 6. Comparison of surface subsidence on the east side. Figure 3. When l=1.8m, horizontal displacement map. Figure 4. When l=1.6m, horizontal displacement map. From Figure 2, the horizontal displacement of foundation Figure 3 - Figure 5 show deep horizontal displacements of the slope wall that is at the eastern side of the foundation pit., when the pile spacing is respectively 1.8m, 1.6m and 1.4m. The results of calculation show that the deep horizontal displacement in three cases of changing pile spacing can meet the requirement that is not greater than 30.0mm. Figure 6 is the ground subsidence corresponding to different pile spacing. By reducing the spacing of pile, the surface subsidence on the east slope wall of the foundation pit is decreased gradually, but the influent range is mainly within the range of 12.0m in the slope wall. When the pile spacing is reduced to 1.4m, the maximal value of surface subsidence is 14.320mm, and less than 15mm, which meet the requirements of the maximal displacement of the building foundation. (2) The influence of pile diameter on deformation From Figure 7, the horizontal displacement of foundation pit significantly is reduced with pile diameter increased. When the pile diameter is increased from 1.0 m to 1.6m, the maximal horizontal displacement is reduced from 24.774mm to

76 Ding Jihui et al.: Zoning Supporting Design of Deep Foundation Pit Based on Controlling Deformation of Surrounding Buildings 18.884mm. When the diameter of pile is changed to 1.6m, the maximal horizontal displacement of the slope wall is less than 20mm, which can be meet the design requirements. Figure 10. When d=1.6m, horizontal displacement map. Figure 7. The horizontal displacement of the east slope wall with different pile diameter. Figures 8-10 show deep horizontal displacements of the east slope wall at different positions, when the pile diameter is respectively1.2m, 1.4m and 1.6m. The results of calculation show that the result in three cases of changing pile diameter can meet the requirements of deep horizontal displacements that is not greater than 30.0mm. Figure 11. Comparison of surface subsidence on the east side. Figure 11 is the ground subsidence corresponding to different pile diameter. By increasing the diameter of pile, the surface subsidence on the east slope wall of the foundation pit is decreased gradually. When the pile diameter is increased to 1.6m, the maximal value of surface subsidence is decreased 14.216mm, and less than 15mm, which meet the requirements of the maximal displacement of the building foundation. Figure 8. When d=1.2m, horizontal displacement map. Figure 9. When d=1.4m, horizontal displacement map. 4.2. Deformation Analysis of Slope Wall on West Side There are underground pipelines on the west side of the foundation pit, and the deformation and displacement of the underground pipelines need to be controlled when the soil body is excavated. The difference between the horizontal displacement and the settlement of the middle slope wall is reduced as much as possible, so as to reduce the influence of the excavation on the underground pipeline around the slope wall. (1) Influence of pile spacing on deformation With the distance from negative angle of foundation pit increased, top level displacement increases gradually, and the maximal value is 13.368mm. In the middle of the slope wall, the maximal horizontal displacement of the deep wall and the maximal value of the surface subsidence are 13.458mm and 7.889mm. Due to the deformation of the slope within 12m of

International Journal of Architecture, Arts and Applications 2017; 3(5): 73-78 77 the foundation pit, the deformation of slope wall is small, and the spacing of pile is increased to 2.1m so as to reduce the settlement difference. Figure 12 is the horizontal displacement of the west slope wall near the foundation pit, and Figure 13 is the surface subsidence of the west slope wall near the foundation pit. From Figure12 and Figure 13, the displacement and settlement difference at the middle of the foundation pit is reduced. Figure 14. When d=0.9 m, horizontal displacement map in the west side. Figure 12. When l=2.1m, horizontal displacement map in the west side. Figure 15. When d=0.9m, the surface subsidence on the west side. 5. Conclusion Figure 13. When l=2.1m, the surface subsidence on the west side. (2) The influence of pile diameter on deformation Figure 14 and Figure 15 is the map of deep horizontal displacement and subsidence, when pile diameter within the range that is 12m away from the corner of the west slope is reduced to 0.9m. The calculation results of increasing spacing are similar to those of reducing the pile diameter. When the diameter of the pile is reduced to 0.9m, or the center distance of the pile is increased to 2.1m in west corner of the foundation pit that is 0.1K (K is the length of the slope wall), it can reduce displacement and different settlement so as to ensure the use of the surrounding underground pipeline effectively. According to the different deformation requirements of deep foundation pit, a new method of partition design in deep foundation pit is put forward, to ensure that the deformation of surrounding soil will not affect the normaluse and safety of the surrounding buildings and foundation pit construction. (1) When there is building on the outside of foundation pit wall and the building is located the middle side of the slope wall, the effect of building on horizontal displacement of foundation pit is mainly happened in the middle of the slope wall, and the range is (0.22~0.78) L or 1.85A (A is the length of the building). When the pile spacing in the range that is 1.85A in the eastern slope wall is reduced to 1.4m, or the pile diameter is increased to 1.6m, the horizontal displacement, deep horizontal displacement, surface settlement and the maximal settlement, different settlement of the building can be controlled. (2) The 0.1K (K is the length of the slope wall) on the west side of the foundation pit has obvious spatial effect. In order to protect the normal use of the underground pipelines on the west side of the slope wall and reduce the differential deformation, the pile spacing within the 0.1K away from the corner is increased from 0.9m to 2.1m, or the pile diameter is decreased from 1.0 to 0.9.

78 Ding Jihui et al.: Zoning Supporting Design of Deep Foundation Pit Based on Controlling Deformation of Surrounding Buildings References [1] Lee, F. H. Yong. K. Y. QUAN, K. C. N. and CHEE, K. T. Effect of corners in strutted excavations: field monitoring and case histories [J]. Journal of Geotechnical and Geoenvironment Engineering, 1998, 124(4):339-348. [2] Ding Jihui, Yuan Man & Zhang Qin. The analysis of spatial effects of the soil pressure on cantilever retaining structure based on elastic resistance method [J]. Engineering Mechanics, 2012:29(S1): 136-140. [3] Ding Jihui, Zhang Qin, Han Lijun et al. Calculation method of soil pressure utilization factor on cantilever supporting structure of deep excavation [C]. International Conference on Electric Technology and Civil, Wuhan, China, 2011: 4830-4837. [4] Yuan Man, Ding Jihui & Zhang Qin. Analysis of Spatial Effects of Earth Pressure on Two-row Pile Structure of Foundation Pit Based on Elastic Resistance Method [J]. Open Journal of Civil Engineering, 2011. [5] Ding Jihui, Fan Fei, etc. Monitoring and Analysis of Deformation Laws of Deep Foundation Pit Considering Spatial Effect [J]. International Journal of Engineering Research & Science,2016:2(9):64-71. [6] Wang Weiyu & Zhao Tuo. Numerical analysis of space effect of foundation pit excavation under unsupported condition [C]. Proceedings of the 25th National Conference on Structural Engineering, 2016, (2):56-59. [7] Jihui-Ding, Taotao-Li, Xiaohui-Wang etc.. Analysis of Interaction between Adjacent Buildings and Deformation of Foundation Pit [J]. International Journal of Engineering and Technical Research, 2017,7(7):102-109. [8] Clough G W, O Rourke T D. Construction induced movements of in situ walls [C]//Design and performance of earth retaining structures. ASCE, 1990: 439-470. [9] Ou C Y, Hsieh P G, Chiou D C. Characteristics of ground surface settlement during excavation [J]. Canadian Geotechnical Journal, 1993, 30(5):758-767. [10] GB 50007-2011, Code for design of building foundation [S]. Beijing: China Architecture& Building Press, 2012. [11] GB50497-2009, Building foundation pit monitoring technical specifications [S]. China Architecture& Building Press, 2011. [12] GB50202-2002, Code for acceptance of construction quality of building foundation [S]. China Architecture& Building Press, 2002.