URSA MINERAL WOOL URSA HOMETEC Cladding Roll

Similar documents
URSA 20 Plus and URSA 20

URSA MINERAL WOOL URSA Façade N32 & Façade N35

URSA MINERAL WOOL URSA Timber Frame Roll & URSA Timber Frame Slab

URSA MINERAL WOOL URSA Timber Frame Roll & URSA Timber Frame Slab

URSA MINERAL WOOL URSA 10 & URSA 20 DIVERSO Loft Roll

URSA MINERAL WOOL URSA Acoustic Roll

URSA TF Roll URSA GLASSWOOL.

URSA ACOUSTIC ROLL URSA GLASSWOOL.

URSA GLASSWOOL URSA 10 Loft Roll

URSA MINERAL WOOL URSA Cavity Batts

URSA 10 Loft Roll Insulation for Cold Pitched Roofs

URSA Acoustic Roll Acoustic Insulation for Floors and Walls

URSA Cavity Batts URSA GLASSWOOL.

August 2008: Issue 1. Non - Residential New Build Built - up Metal Walls

Built-up metal walls. Built-up metal wall design. 3.3 Built-up Metal Walls

PlyLok. Product Guide PIR and Plywood Laminate Insulation for Warm Flat Roofs.

April Section 3.3. Built-up Metal Walls

Thermal bridging. Acoustic performance

August 2008: Issue 1. Non - Residential New Build Built-up Metal Roofs

April Section 2.4. Built-up Metal Roofs

Superior Performance Phenolic Insulation. SR/FB Insulation for Steel and Timber Frame. Walls AS LOW AS 10/4803

Superior Performance Phenolic Insulation. SR/FB Insulation for Steel and Timber Frame. Walls AS LOW AS 10/4803

Superior Performance PIR Insulation. XO/FB Insulaton for Steel & Timber Frame. Walls 12/4956

Superior Performance PIR Insulation XO/FB. Insulaton for Steel & Timber Frame. Walls 12/4956

Eurothane EuroDeck. Product Guide PIR insulation for Warm Flat Roofs.

Eco-Versal. insulation. Polyisocyanurate (PIR) foam core with aluminium foil composite to both sides BASELINE TOPLINE SLIMLINE

Glasswool UK February 2008

Superior Performance Phenolic Insulation SR/PR. Insulation for Pitched Roofs. Roofs AS LOW AS 10/4803

PIR Insulation. XT/PR Insulation for Pitched Roofs. Roofs 08/ /0183

PowerDeck F. PIR insulation for Warm Flat Roofs. Product Guide

Basement Board High Performance (HP) 70 and 100

PIR Insulation XT/TL-MF. Insulation for Drylining Walls (Mechanically Fixed) Walls 04/ /0183

Jabfloor 70, 100, 150, 200, 250

Superior Performance Phenolic Insulation SR/UF. Insulation for Ground Supported and Suspended Floors. Floors AS LOW AS 10/4803

Jabfloor High Performance (HP) 70 and 100

RAINSCREEN DUO SLAB. Non-combustible thermal insulation

RW SEMI-RIGID AND RIGID SLABS (RWA45, RW3, RW4, RW5 & RW6)

Jablite Board 250, 300, 350, 400 and 500

Xtratherm Thin-R Underfloor Board (XT/UF Grade)

PIR Insulation. XT/UF Insulation for Ground Supported and Suspended Floors. Floors 08/ /0183

Light steel frame walls

June Residential New Build Timber Frame Walls

REFLECTIVE TECHNOLOGY CONSTRUCTION MEMBRANES

PIR Insulation XT/TF. Insulation for Timber Framed Walls. Walls 08/ /0183

MINERAL WOOL INSTALLATION GUIDANCE: ENSURE A PERFECT FIT

K15 Rainscreen Board. Insulation INSULATION FOR USE BEHIND RAINSCREEN CLADDING SYSTEMS

Polyfoam Floorboard For thermal insulation of floors

Superior Performance Phenolic Insulation. SR/RS Insulation for Ventilated Rainscreen Cladding. Walls 10/4803

Jabfloor 70 Floor insulation Suspended timber floor

NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. Date of update May 30, 2018 Valid until May 29, 2023 HYBRIS

PIR Insulation XT/CW (T&G) Insulation for Partial Fill Cavity Walls. Walls 08/ /0183

Superior Performance Phenolic Insulation. SR/CW Insulation for Partial Fill Cavity Walls. Walls AS LOW AS 10/4803

Thermal Laminate Board.

PRODUCT CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE

Superior Performance Phenolic Insulation SR/TB. Insulation for Drylining Walls Fixed with Adhesive Dabs. Walls AS LOW AS

Multi-layer Insulation Blanket for

Type Jablite board is available as EPS 100, 150, 200, 250 as defined in BS EN Flame-retardant additive material is available to order.

April Section 4.3. Separating Floors

Suspended timber upper floors

PIR Insulation. XT/Walk-R. Insulated Loft Decking. Roofs

PIR Insulation XT/TL. Insulation for Drylining Walls Fixed with Adhesive Dabs. Walls 04/ /0183

RAINSCREEN CLADDING SOLUTIONS

TECHWRAP2 AND TECHTUBE Acoustic solutions for pipework and equipment

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

June Non - Residential Refurbishment Separating floors

An introduction to Part L U-values

Refurbishment site guidance for solid-walled houses roofs

K17 Insulated Plasterboard

SEPTEMBER construction type cavity barriers. SP Firestop Systems. The purpose-made solution for cavity fire stopping

APPLICATION: Roof insulation warm pitched roof

PITCHED ROOF SOLUTIONS

June Residential Refurbishment Separating walls

Superior Performance PIR Insulation. Roofs. XO/SK (T&G) Insulation for Sarking Warm Roof Construction

Floors Walls Roofs. Jablite Premium board Jablite board. APPLICATION: Internally Lined Pitched Roof PRODUCTS: Vencel Resil Limited

T-Barrier System. Masonry Applications. Satisfying Fire, Thermal and Acoustic Requirements at the Combined Party Wall and Pitched Roof Junction

T-Barrier System. Timber Frame Applications. Satisfying Fire, Thermal and Acoustic Requirements at the Combined Party Wall and Pitched Roof Junction

SIDERISE CBX flexible acoustic barriers for suspended ceilings

HIGH-PERFORMANCE ROOFING UNDERLAYS AND BUILDING MEMBRANES

POLTERM MAX PLUS. Non combustible stone wool insulation for ventilated rainscreen cladding and overcladding systems. isover.co.uk

Fire protection for timber frame & masonry cavity walls

April Section Cladded Walls

Multi-layer Insulation Blanket for Walls

Ductslab and Ductwrap

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks.

TCB & PWCB CAVITY BARRIERS Fire Protection for timber/steel frame & masonry cavity walls

Flat roofs. Flat roof design. 2.3 Flat Roofs

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

fire, thermal & acoustic insulation

June Residential Refurbishment Separating floors

Multi-layer Insulation Blanket for Walls

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Superior Performance PIR Insulation. XO/PR Insulation for Pitched Roof. Roofs 12/4956

NEW Not just a vapour control layer, it also acts as supplementary insulation! HCONTROL REFLEX+

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

SOUND INSULATION SLAB A family of fire resilient stone wool insulation products optimised for soundproofing

ROCKFLOOR. Thermal and acoustic stone wool insulation for ground and separating floors

SP FIRESTOP SYSTEMS The purpose-made solution for cavity fire stopping

DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks.

Multi-layer Insulation Blanket for Walls

Transcription:

Clad 073_Layout 1 02/10/2017 10:37 Page 1 UK LTD Crest House 102-104 Church Road Teddington, Middlesex TW11 8PY United Kingdom Tel : 020 8977 96 97 Fax : 020 8977 94 56 Web : www.ursa-uk.co.uk E-mail : ursauk@ursa.com MINERAL WOOL Insulation for Built-up Metal Systems BROUK-0014-09/17

Clad 073_Layout 1 02/10/2017 10:37 Page 3 The Company As a leading supplier of insulation and insulating systems, has succeeded in fully addressing user requirements for thermal and acoustic insulation. Quality products for every application and excellent customer support are the cornerstones of the corporate culture. is the number two manufacturer of glass wool and extruded polystyrene products in Europe. At 13 production sites, has 2,000 employees generating sales revenues of over 500 million. mineral wool is manufactured in Spain, France and Belgium, at two sites has in Germany, in Slovenia, Hungary and Poland as well as in two Russian plants. Our closely-woven network of sales offices stretches across Europe and Russia. Almost everywhere is amongst the market leaders. In Russia and in a number of other Eastern European countries, we are number one in the glasswool segment. We have also enjoyed a strong position particularly on the growth markets of the new EU partner countries from the very beginning. s are lightweight, non-combustible, unfaced glass mineral wool products for use in built-up metal wall and roof systems. The thermal conductivity of 40 is 0.040 W/mK, for 35 it is 0.035 W/mK and for 32 it is 0.032 W/mK. Benefits Quality Outstanding product quality manufactured to ISO 9001 Quality Systems. Global warming potential does not use chemical blowing agents and so the Global Warming Potential (GWP) arising from it is zero. Insulation savings It is possible to meet the Building Regulation requirement with 160mm of. User friendly Our new generation TERRA mineral wool has a soft touch feel making it easier to handle and install whilst still maintaining its excellent mechanical properties. Cost effective Rapid and simple construction means this is a very cost effective way of insulating new buildings or upgrading existing. Acoustics has excellent sound insulation characteristics and enhances the acoustic comfort of the building. Environment mineral wool is manufactured from an abundant, sustainable resource and may utilises at least 50% glass waste. Fire performance is classed as non-combustible. Handling is lightweight yet tough, resilient and easy to install. It is easily cut using a sharp knife. Space saving Compaction of the rolls in their manufacture saves space in both storage and transport. Durability is rot-proof, durable and maintenance free. It is non-hygroscopic and will not slump in normal use. All of our products carry the CE Mark to show compliance with the harmonised European Standard BS EN 13162 and are quality assured to ISO 9001. 2 3

Clad 073_Layout 1 02/10/2017 10:37 Page 5 Design Acoustics Metal roofing and systems comprise an inner tray with spacer brackets and sheeting rails onto which is fixed the external (See Figure 1). The space created by the brackets and rails is used to accommodate the mineral fibre insulation. Due to the nature of this type of construction there are a number of specific design considerations that must be accounted for - detailed design advice is available from the Metal and Roofing Manufacturers Association (MCRMA) and the Steel Construction Institute (SCI). The following summarises the critical features. Spacer Brackets The metal spacer brackets penetrate the thickness of the insulation and introduce a considerable amount of thermal bridging. The brackets should incorporate a thermal break to minimise this effect. Thermal Bridging With increasing levels of insulation it is vitally important to ensure continuity of the insulation at the junction of elements. The full insulation thickness should be maintained throughout the whole wall or roof area with special care taken at corners, junctions and around openings. The insulation should be tightly butted together to allow the fibres to knit and prevent any gaps. Limiting Air Infiltration Unwanted and uncontrolled air infiltration is a major source of heat loss. The Building Regulations now place limits on the air infiltration rate which must be measured on the completed building. Simple measures include sealing the laps in the inner sheet, incorporating an air infiltration barrier (the vapour control layer may perform this function) and sealing gaps around penetrations and openings. Condensation With increasing levels of insulation the increased risk of interstitial condensation must be carefully considered see BS 5250 for detailed design advice. Measures that should be taken include: Removal of the water vapour at source by the use of suitable ventilation and/or extract fans in high humidity areas. The use of a correctly detailed and carefully sealed air and vapour control layer (AVCL) (formed either by sealing the laps in the tray or providing a minimum 500g polythene sheet) to reduce the amount of water vapour from the habitable area passing into the cold void above the insulation. The AVCL should be continuous with special care being taken at the junctions of elements and around openings and penetrations. Provide ventilation above the insulation to remove any moisture laden air. BS 5250 recommends that the voids of the external should be ventilated at both ends with ventilated fillers giving a minimum opening of not less than 5% of the sheet void above the rails. Ensure that birds, insects and vermin cannot enter via the vents. Figure 1 General Roof Detail Bracket Inner panel Thermal break pad Sheet metal and roofing may suffer intermittent condensation problems on clear, cloudless nights due to clear night sky radiation. This causes the metal to fall to a temperature considerably below the ambient temperature producing condensation on the underside of the external. The use of a breather membrane should be considered to allow any droplets of condensate to drain away to the gutters. Design Loadings The load exerted on the will vary according to geographical location, site location and building height. Calculations relating to the bracket and rail fixing pattern should be made with reference to BS EN 1991, Eurocode 1; Actions on Structures. Fire Performance When used within a system constructed in accordance with this brochure will enhance the fire resistance properties of the roof or wall achieving up to 240 minute fire integrity. Generally the profiled will achieve the best external fire rating of EXT.SAA (sloping roofs) or EXT.FAA (flat roofs). Fire stopping in the form of mineral fibre insulation should be used at party/separating walls. Rail Acoustics Lightweight roof and wall systems can readily transmit sound. has excellent acoustic properties which can reduce the overall sound transmission to acceptable levels. A typical, un-insulated twin skin metal wall or roof will give approximately 30 db sound reduction. This can be improved to more than 40 db with the addition of 200mm, perhaps as high as 50 db with a suitably designed system. This works in two ways; either keeping noise from inside the building (for example a factory environment) from annoying nearby residents or by preventing noise pollution from outside the building (e.g. a nearby motorway or airport). Similarly mineral fibre insulation may be used to control the acoustic performance inside the building. Large, open plan buildings may suffer excessive sound reverberation which can be controlled by suitable mineral fibre linings. A perforated inner tray allows sound energy to penetrate and be absorbed and dissipated by the mineral fibre within the roof or wall structure. Typically this detail includes a relatively thin layer of tissue faced mineral fibre as the acoustic insulation followed by the vapour control layer and main thickness of (thermal) insulation (see Figure 2). Figure 2 Acoustic Systems Perforated Air and vapour control layer Acoustic insulation 4 5

Clad 073_Layout 1 02/10/2017 10:37 Page 7 Installation Bracket & Rail Systems (See Figures 3, 4 and 5) is designed to be laid on the inner lining sheet and held in place by the spacer brackets and sheeting rails. The usual procedure for construction is: 1. The structural framing, inner sheet, metal spacer brackets (with thermal break) and sheeting rails are installed in accordance with the manufacturer s instructions. 2. A polythene air and vapour control layer (AVCL), if required, is fixed on the with all joints lapped and sealed with special care being taken at the junction of elements. Alternatively the laps in the inner sheet may all be sealed to create the vapour control layer. 3. The is laid on the inner sheet ensuring there are no gaps in the insulation, around the brackets or around openings and penetrations. The insulation is slid under the sheeting rails where it will be slightly compressed. 4. If required a breather membrane is laid over the insulation prior to installing the external sheeting. 5. The profiled external sheeting should be installed as soon as possible after laying the to avoid exposure to the weather. Lay only sufficient insulation that can be covered and protected on the same working day, otherwise provide temporary protection. Provide temporary protection during bad weather including rain, wind and snow or freezing conditions. 6. Ensure that any penetrations through the wall/roof, especially if formed by following trades, are correctly sealed to ensure an air and vapour tight ceiling. Figure 3 Bracket & Rail Systems Steel frame Inner sheet Figure 4 Wall Detail (horizontal ) Inner sheet Sheeting rail Spacer bracket Rail on spacer brackets Liner Tray Systems (See Figure 6) is designed to be laid in the tray and held in place by the external. The usual procedure for construction is: 1. The structural framing and inner tray (with thermal break) are installed in accordance with the manufacturer s instructions. 2. The laps and joints in the tray should all be sealed to create the air and vapour control layer (AVCL). 3. The is laid in the tray ensuring there are no gaps in the insulation or around openings and penetrations. 4. If required, a breather membrane is laid over the insulation prior to installing the external sheeting. 5. The profiled external sheeting should be installed as soon as possible after laying the to avoid exposure to the weather. Fit only sufficient insulation that can be covered and protected on the same working day, otherwise provide temporary protection. Provide temporary protection during bad weather including rain, wind and snow or freezing conditions. 6. Ensure that any penetrations through the wall/roof, especially if formed by following trades, are correctly sealed to ensure an air and vapour tight ceiling. Figure 5 Roof Detail Inner panel Thermal break pad Figure 6 Liner Tray Systems Liner tray Steel frame Rail Bracket Insulation as thermal break 6 7

Clad 073_Layout 1 02/10/2017 10:37 Page 9 Suspended Ceiling Heat Loss Calculations is designed to be laid above the foil backed plasterboard ceiling. The usual procedure for construction is: 1. The structural framing and system are installed in accordance with the manufacturer s instructions. 2. The support system for the plasterboard ceiling such as a T-bar system suspended from the structural frame (fixed in accordance with the manufacturer s instructions) or timber battens is then installed. 3. Fix foil backed plasterboard to the support system and correctly seal any joints. 4. The is laid on the plasterboard ceiling ensuring there are no gaps in the insulation, around the suspension wires or around openings and penetrations. 5. Ensure that any penetrations through the ceiling, especially if formed by following trades, are correctly sealed to ensure an air and vapour tight ceiling. Figure 7 Suspended Ceiling Foil backed plasterboard in T-Bar system The normal method of calculating U-values in floors, walls and roofs is the Combined Method (see BS EN ISO 6946). This method cannot be used with metal systems however as the heat loss pattern is considerably more complex due to the metal spacer brackets and sheeting rails. Reference must be made instead to document P312, Metal : U-value Calculation, from the Steel Construction Institute (SCI) which gives a simplified method of either calculating the U-value from first principles or estimating it from graphs. For systems that use Z-spacers refer to BRE Information Paper IP 10/02: Metal : assessing the thermal performance of built-up systems using Z-spacers. Compliance with the Building Regulations is shown by limiting the overall CO 2 emissions from the building this gives considerable design flexibility but there are no specific U-values, except the worst allowable, that must be achieved. The following pages give typical U-values that can be achieved using based on the following typical construction. To summarise the requirements: Walls In new build a U-value of 0.25 W/m 2 K or better will help ensure compliance. In extensions a U-value of 0.28 W/m 2 K is required and in refurbishment work 0.30 W/m 2 K is required. The Building Regulations (Scotland) require a U-value of 0.23 W/m 2 K or better. Roofs In new build a U-value of 0.16 W/m 2 K or better will help ensure compliance. In extensions and refurbishment work a U-value of 0.18 W/m 2 K is required. 0.7mm profiled steel outer sheet. 0.4mm profiled steel inner sheet. 0.67 spacer brackets per square metre. 60mm 2 cross sectional area. Conductivity 60 W/mK. C Section rails @ 1500mm c/c. 40mm depth. 40mm width. Conductivity 60 W/mK. 8 9

Clad 073_Layout 1 02/10/2017 10:37 Page 11 Heat Loss Calculations 32 32 (mm) Wall U-Value (W/m 2 K) Roof U-Value (W/m 2 K) 100 0.33 0.33 120 0.28 0.28 140 0.24 0.24 160 0.21 0.21 180 0.19 0.19 200 0.17 0.17 220* 0.16 0.16 240* 0.14 0.14 260* 0.13 0.12 280* 0.12 0.12 * Double layer systems 35 35 (mm) Wall U-Value (W/m 2 K) Roof U-Value (W/m 2 K) 100 0.36 0.37 120 0.30 0.31 140 0.26 0.26 40 40 (mm) Wall U-Value (W/m 2 K) Roof U-Value (W/m 2 K) 100 0.40 0.41 120 0.34 0.34 140 0.29 0.30 160 0.26 0.26 180 0.23 0.23 200 0.21 0.21 220 0.19 0.19 240 0.17 0.18 260 0.16 0.16 280 0.15 0.15 300 0.14 0.14 These values are indicative only as each system will be slightly different depending upon the exact system specification. For the U-value of other wall or roof details please contact UK Technical Services or your system manufacturer. 150 0.24 0.25 160 0.23 0.23 180 0.21 0.21 200 0.19 0.19 220 0.17 0.17 240 0.16 0.16 265 0.14 0.14 280* 0.13 0.13 * Double layer systems 10 11

Clad 073_Layout 1 02/10/2017 10:37 Page 13 Technical Details Thermal Conductivity Declared thermal conductivity of 32 is 0.032 W/mK. Declared thermal conductivity of 35 is 0.035 W/mK. Declared thermal conductivity of 40 is 0.040 W/mK. Declared thermal conductivity tested to BS EN 13162. Density Nominal density of 32 is 32 kg/m 3. Nominal density of 35 is 22 kg/m 3. Nominal density of 40 is 12 kg/m 3. Reaction to Fire Euroclass A1 to BS EN 13501-1. 32 Moisture Vapour Transmission has minimal resistance to the passage of water vapour, thus allowing the roof to breathe. A practical value for the moisture vapour resistivity is 5 MNs/gm. Specific Heat Capacity The specific heat capacity is 0.84 kj/kgk. Designation Code 32; MW EN 13162 T3 WS MU1. 35; MW EN 13162 T2 DS(70,-) MU1 AFr5. 40; MW EN 13162 T1. Environmental Information BRE Green Guide All mineral wool products achieve the best possible A+ rating under the BRE Green Guide. Manufactured to BS EN ISO 14001. Thickness (mm) Length (m) Width (mm) Pack Size (m 2 ) 60 5.40 1200 6.48 80 5.40 1200 6.48 100 5.40 1200 6.48 120 2.70 1200 3.24 140 2.70 1200 3.24 160 2.70 1200 3.24 180 2.70 1200 3.24 200 2.60 1200 3.12 35 Thickness (mm) Length (m) Width (mm) Pack Size (m 2 ) 60 10.00 1200 12.00 80 8.00 1200 9.60 100 6.00 1200 7.20 120 5.00 1200 6.00 140 4.00 1200 4.80 150 4.00 1200 4.80 160 3.50 1200 4.20 180 3.00 1200 3.60 200 3.00 1200 3.60 220 3.00 1200 3.60 240 2.70 1200 3.24 265 2.40 1200 2.88 40 Thickness (mm) Length (m) Width (mm) Pack Size (m 2 ) 60 13.50 1200 16.20 80 10.50 1200 12.60 90 9.00 1200 10.80 100 8.50 1200 10.20 120 7.50 1200 9.00 140 6.50 1200 7.80 160 5.50 1200 6.60 180 5.00 1200 6.00 200 4.50 1200 5.40 220 4.00 1200 4.80 240 3.75 1200 4.50 260 3.50 1200 4.20 280 2.80 1200 3.36 300 2.60 1200 3.12 12 13

Clad 073_Layout 1 02/10/2017 10:37 Page 15 Technical Details Durability When correctly installed, mineral wool products are maintenance free and have an indefinite life at least equal to that of the building. Storage mineral wool products are supplied wrapped in polythene to provide short-term protection. On site the rolls should be stored clear of the ground, on a clean level surface and under cover to protect them from prolonged exposure to moisture or mechanical damage. Chemical Compatibility mineral wool products are compatible with all common construction materials, alkalis, dilute acids, mineral oil and petrol. Products that have been in contact with harsh solvents, acids or saturated with water should not be used. Health and Safety mineral wool products are inherently safe to handle. During cutting or handling any dust generated is of nuisance value only; the wearing of dust masks, gloves and long sleeved clothing is recommended. Large scale machining should be connected to a dust extraction system. A comprehensive Health and Safety data sheet is available from UK Ltd upon request. Availability is available nationally through insulation distributors and builders merchants. References The Building Regulations and supporting documents. Thermal Insulation: avoiding risks (2002). Metal Wall Systems Design Guide Technical Paper 5 (MCRMA). Profiled Metal Roofing Design Guide Technical Paper 6 (MCRMA). Acoustic Design Guide for Metal Roof & Wall Systems Technical Paper 8 (MCRMA). Metal : U-value Calculation P312 (Steel Construction Institute). Best Practice Guide for the Specification and Installation of Metal & Secondary Steelwork P346 (Steel Construction Institute). BRE Information Paper IP 10/02: Metal : assessing the thermal performance of built-up systems using Z-spacers (BRE). CIBSE Guide A3 Thermal Properties of Building Structures. BS 5427 Code of Practice for the use of Profiled Sheet for Roof and Wall on Buildings. BS 5250 Code of Practice for Control of Condensation in Buildings. BS 6399 Loadings for Buildings. MCRMA Technical Papers, BRE Digests, Information Papers and Good Building Guides. 14