Each proposed project will be reviewed for compliance with the following codes as applicable.

Similar documents
RESIDENTIAL CONSTRUCTION New Dwellings and Additions

Minimum Residential Plan Submittal Requirements

One and Two Family Additions

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008)

* RESIDENTIAL PLAN REVIEW *

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

UCC Permit Application Procedures

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches

2003 International Residential Building Code

Borough of Doylestown Building and Zoning Department

#402 New Residential Submittal Checklist

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

Building Guide. Colorado Chapter of the International Conference of Building Officials. Building Guide

Administrative Changes

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept.

Town of Pawling Residential Building Permit Application

RESIDENTIAL BUILDING PLAN REQUIREMENTS

The Homeowner s Building Application Checklist for Constructing a Residential Addition

Residential Plan Review for New One and Two Family Dwellings

Town of Pawling Residential Building Permit Application

Residential Accessory Structures & Room Additions

Residential Building Plans

#406 Residential Addition, Alteration & Accessory Building Submittal Checklist

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction.

Building Guide. Colorado Chapter of the International Code Council

MINIMUM PLAN INFORMATION REQUIRED FOR A BUILDING PERMIT

Applying for Permits to build a new house in Linn County

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

Residential Building Inspections

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

City Planning & Development - Development Services (CPD-DS) 414 E. 12th Street 5 th Floor Kansas City, Missouri Telephone (816)

SFR SUBMITTAL REQUIREMENTS

Basement Build-Out Guidelines

One & Two Family Residential ADDITIONS

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

CITY OF OAK CREEK SINGLE FAMILY & TWO-FAMILY CONSTRUCTION/PERMIT REQUIREMENTS

General Residential Code Requirements

Minimum Requirements For One & Two Family Structures FBC 6 th Edition (2017)

General Residential Code Requirements

Basement Finish/Remodel Permit Information Revised 10/2/18

Basement Finish/Remodel Permit Information Revised 10/2/18

Elko County Building & Safety Division

Residential Building Permit Application

SUBMITTAL REQUIREMENTS FOR SINGLE FAMILY DWELLINGS

FRAMING INSPECTION GENERAL

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

Proud of its Heritage, Preparing for its Future

One & Two Family Residential NEW CONSTRUCTION Plan Review Checklist

INDIANA COUNTY Office of Planning and Development 801 Water Street Indiana, PA (724) Fax (724)

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

BUILDING PERMIT INFORMATION GUIDE FOR THE HOMEOWNER

Village of Glen Ellyn Basement Remodeling Project Guidelines

Scale Drawing This drawing will need to show the full lot and location of the proposed

CRM Homes BUILDER Mangan Drafting Jim Mangan

Residential Building Permit Application

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)

CODE COMPLIANCE GUIDELINE GENERAL BUILDING

APPLICATION FOR FINISHED BASEMENT PERMIT

Elevations. Front Elevation. Left Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,647.

ONE AND TWO FAMILY DWELLING PERMIT APPLICATION REQUIREMENTS

MINIMUM REQUIREMENTS FOR CONSTRUCTION PLANS, GRADING AND/OR DRAINAGE PLANS, LOW IMPACT DEVELOPMENT PLANS, AND WATER EFFICIENT LANDSCAPE PLANS

Left Elevation. Front Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,842. Scale : 1/4" = 1'

Permit Posting and Inspection Procedures

District of Ucluelet Building Permit Guide

Village of Corrales Planning and Zoning Department

Elevations. Front Elevation. Left Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,647.

BASEMENT FINISH CONSTRUCTION PLANS REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS

Two complete sets of plans that are legible and drawn to conventional scale are required to be submitted with the Building Permit Application Form.

Specific Plan Check Requirements for Residential Construction

BUILDING CODES & DESIGN CRITERIA

CITY OF FATE SINGLE FAMILY BUILDING PERMIT PACKET. Adopted Codes:

BUILDING A NEW HOME. Construction Permit Tips For Home Owners

Contractor/Owner initials are verification that items #1 and #2 and items (a) thru (g) above are included in the submitted plan/drawing.

Boss Inspection Inc Wisconsin Uniform Dwelling Code Inspection and Code Enforcement

Washoe County PLAN SUBMITTAL

SINGLE FAMILY/DUPLEX/T.H. REPEAT PLAN APPLICATION

General Residential Code Requirements

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

COMMERCIAL OR RESIDENTIAL NEW BUILDINGS, REMODELS AND ADDITIONS

PLAN REVIEW REQUIREMENTS FOR RESIDENTIAL CONSTRUCTION

TOWN OF FRANCESTOWN BUILDING/CODE ENFORCEMENT 27 MAIN STREET P.O. BOX 5 FRANCESTOWN, NEW HAMPSHIRE Building Permit Application Guide

R vertical and horizontal.

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

2012 Code Update Training

Building Permit Requirements for New Residential Dwellings and Additions Code Enforcement Office ( )

*FOR RESIDENTIAL PROJECTS, CALL JACK CARNS AT *FOR COMMERCIAL PROJECTS, CALL BRIAN WRUBLE AT

Commercial and Residential Projects (after appropriate Board approvals have been made if necessary):

C ITY OF D ARIEN Community Development Department 1702 Plainfield Road Phone: (630) Fax: (630)

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

1 AND 2 FAMILY DWELLING REQUIREMENTS

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

CITY OF DANA POINT WINDOW REPLACEMENTS FOR R-3 B030 WINDOWS

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

Office use only 115 S. FRANKLIN AVE. Permit No. POLO, IL 61064

PLANNING DEPARTMENT. Introduction

INSULATION INSTALLATION

Transcription:

VILLAGE OF PALATINE DEPARTMENT OF BUILDING AND INSPECTION SERVICES 200 EAST WOOD STREET PALATINE, IL 60067-5339 Telephone (847)359-9042 Obtaining a Residential Building Permit: Submittal Requirements The Village of Palatine Building Division has created this customer information document to inform the general public about the effect of codes and regulations on their projects. These documents are not intended to be complete statements of all laws and rules and should not be used as substitutes for them. If conflicts and questions arise, current codes and regulations are final authority. Because the codes and regulations may be revised or amended at any time, consult Village of Palatine Building staff to be sure you understand all requirements before beginning work. It is the applicant s responsibility to ensure that the project meets all requirements of applicable codes and regulations. Residential Codes This document serves as a guideline to help customers understand the requirements for obtaining a residential building permit. Please keep in mind that the detail in this bulletin pertains only to residential structures with one primary dwelling unit or to accessory dwelling units. Residential structures with two or more primary dwellings without individual entries are considered to be commercial developments, the application requirements for which are outlined in the Commercial and Multi-family Building Permit Submittal Requirements document. For smaller residential projects such as fences, decks, sheds, driveways and other similar projects, express permits are available. Express permits are processed in 3 business days. Visit the Building and Inspection Services website at https://www.palatine.il.us for more information. Each proposed project will be reviewed for compliance with the following codes as applicable. (1) International Residential Code, 2009 Edition (with amendments). (a) Sizing and Capacity of Gas Piping, Appendix A (b) Sizing of Venting Systems, Appendix B (c) Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix C (d) Radon Control Methods, Appendix F (e) Swimming pools, Spas and Hot tubs, Appendix G (f) Patio covers, Appendix H (g) Existing buildings and structures, Appendix J (2) International Mechanical Code, 2009 Edition (with amendments). (3) International Fuel Gas Code, 2009 Edition. (4) International Energy Conservation Code, 2015 Edition (5) National Electrical Code, 2011 Edition (with amendments). (6) Illinois Plumbing Code, 2014 Edition (7) Village of Palatine Code of Ordinances The specific rules and regulations that apply to a proposed application will depend upon the type and scope of the proposed project. Permit Submittal Requirements A pre-submittal meeting is required to submit for a residential building permit. To schedule a presubmittal meeting, please contact Mary May at 847-359-9042. Wait times for appointments vary due to seasonal issues and customer demand; however, we will make every effort to schedule appointments within one week of the request. To have an application reviewed and approved in a timely manner, it is critical to have all forms completed and submitted along with other necessary materials at the time of submitting an application for review. Review of applications will not begin until customers/contractors have submitted all required materials and have attended a pre-submittal meeting. Page 1 of 5

In order to obtain a permit for new construction, additions and remodels, customers must provide the following information. A detailed explanation of each is provided later in this document. Incomplete submittals will not be accepted. A. Building Permit Application and Copy of Signed Contract B. Building Permit Contractor List Form C. Current Plat of Survey (3 copies) D. Plat of Survey Affidavit E. Working Drawings (or construction documents, blueprints, plans) (3 copies) F. Manufacturers Specifications for Heating/cooling systems, Fireplaces and Stoves (3 copies) G. Shop Drawings for Specialty Items such as Trusses and Sprinkler Systems (3 copies) H. Miscellaneous (3 copies) Applications and forms are available via the Building and Inspection Services website at http://www.palatine.il.us A. Building Permit Application (1 copy) The Building Permit Application identifies the scope of work, project valuation, property information, property owner, applicant, and other contact information. This form is required for all building permits and must be fully completed. Please be sure to verify that all contact information; names, addresses and telephone numbers are accurate. If an address has not been established, you must contact the Fire Prevention Bureau at (847)359-9029 for address assignment. Incomplete applications will not be accepted. B. Building Permit Contractor List Form (1 copy) Information for each contractor working on the project must be provided. Contractors must be registered and bonded with the Village of Palatine and where applicable with the State of Illinois. This information is not required at time of application but must be provided before a permit will be issued. When choosing a contractor, please refer to the Illinois States Attorney publications website for useful tips. http://www.ag.state.il.us/consumers/consumer_publications.html C. Current Plat of Survey (3 copies) A plat of survey is a drawing that represents a single property that has been surveyed in the field and certified by an Illinois licensed land surveyor. This plat shows all property lines and existing structures on an individual residential lot. Everything on the plat must be drawn to-scale. A plat of survey must include the legal description of the property. If your project involves only interior work and does not add any additional coverage to the lot, a plat of survey is not required. D. Plat of Survey Affidavit When a project is an addition to an existing structure or adding an accessory structure to an existing property, a current plat of survey is not always required. An old plat of survey can be used if it is updated with any improvements that have been added to the property since the date the plat was created. See the plat of survey affidavit form for directions. A plat of survey affidavit is not required when a current plat of survey is submitted. E. Working Drawings (or construction documents, blueprints, plans) (3 copies) Working drawings are graphical pictures of the structure customers are planning to build. Three sets are required to be submitted. These working drawings are used to provide the plan reviewer with information on how applicants plan to construct a proposed project. An Architect is not required to prepare working drawings but at times the use of an Architect can be helpful. If customers plan to build higher than two stories, or plan to use unconventional materials, please contact the building division to set up a meeting to discuss your project specifics. The building official may require additional drawings, details, sections, or stamped engineered calculations and/or details for any building or site. Page 2 of 5

The following drawings are required. All plans should be a minimum of 18 x 24 size paper. Site Plan (no less than 1 = 20 scale); Grading/Utility Plan May be indicated on the site plan (no less than 1 = 20 scale); Foundation Plans - (Required scale: 1/4 =1-0 ); Floor Plans of each floor above the foundation (Required scale: 1/4 = 1-0 ); Building Cross Section(s) - Usually through the most complex area(s) (Required scale 1/4 = 1-0 ); Exterior Elevations - (Recommended scale 1/4 = 1-0 ) for all sides of the building; Roof Framing Plans - May be indicated on the uppermost floor plan (Required scale 1/4-1 - 0 ); Floor Framing Plans - May be indicated on a floor or foundation plan (Required scale 1/4 = 1-0 ); Wall Bracing Plans of each floor above the foundation (no less than 1 = 10 scale); Electrical Plans - May be indicated on the floor plans (Required scale 1/4-1 - 0 ); HVAC Plans - May be indicated on the floor plans (Required scale 1/4-1 - 0 ); Plumbing Isometrics for Waste/Vent and Water (no scale); Miscellaneous Structural Details - (Recommended scale 3/4 = 1-0 ); Typical Wall Section - (Recommended scale 1/2 = 1-0 ). Drawing Sets Shall Be As Follows: Clear and with readable writing; Stapled together with plat of survey as the first sheet; In order, with each page numbered consecutively; No pencil drawings; Reproductions on substantial paper are required. THE WORKING DRAWINGS SHALL EFFECTIVELY DESCRIBE OR SPECIFY THE FOLLOWING 1. Indicate location and type of all of impervious surface areas. (driveways, walks, decks, pools, etc) 2. Existing grading for new structures over 500 square feet in size. 3. Proposed new grading for new structures over 500 square feet in size. 4. Provide percentage of exterior glazing. 5. Indicate the codes used on the cover sheet. 6. Indicate the loading used on the cover sheet. 7. All existing and new underground utilities sanitary, storm, water, etc. 8. Location and dimensions of all property lines and easements and building setback lines. 9. Location and dimensions of all existing and proposed buildings, structures, uses and distances to property lines, other buildings and easements. 10. Line of structure above - particularly overhangs and cantilevers, roofs, etc. 11. Crawl space vents - call out typical size and quantity 12. Crawl space access - call out size of opening 13. Light and vent schedule 14. Footings continuous and pads - call out sizes 15. Columns/post - call out member size 16. Bearing wall - call out for clarity 17. Framing (floor, roof, deck) - show direction of layout, size, species, grade and spacing. 18. Beams & headers - call out size, species and grade. 19. Under slab vapor barrier - 6 mil. polyethylene or equivalent 20. Connectors - beam to beam, post to beam, truss to beam, hangers; call out size. provide detail and engineering for custom fabricated connectors 21. Miscellaneous structural components - show doubled joist, blocking, etc. Page 3 of 5

22. Spaces (rooms) - label areas; (example: crawl space, closet, bedroom, deck, etc.) 23. Heating system - show location and call out size in btuh or other appropriate unit 24. Electrical system show location of panel, receptacles, switches, etc. 25. Stairs - show direction of travel (up or down), dimensions, notes and details 26. Show Plumbing fixture toilets, tubs, whirlpools, sinks, lavs, etc. 27. Mechanical ventilation furnace location, supply and return diffusers 28. Doors - show swing; if pocket door, show pocket area. Indicate sizes 29. Windows - call out size. Indicate if fixed or operable. Window sizes must meet minimum requirements for light and ventilation. Windows in sleeping areas and basements must meet emergency escape requirements. 30. Half walls/guardrails - show height 31. Decking - call out type; 32. Line of floor or ceiling openings - call out stairs, elevator shafts, laundry chutes or dumbwaiters, 33. Skylights - call out size 34. Attic access - call out size 35. Masonry fireplace - provide a cross section 36. Ridges - call out size and species of ridgeboard 37. Hips - call out size and species of hip rafter 38. Valleys - call out size and species of valley rafter 39. Roof framing a. Trusses - show direction of layout; call out spacing. show and label hip masters, hip jacks, end jacks, girder trusses, hangers, bearing areas, etc b. Conventional roof framing - show direction of roof rafter and ceiling joist layout; call out spacing; and c. Show and label rafter ties, purlins, blocking, support joints, bearing points and/or walls, etc. 40. Smoke detectors 41. Carbon monoxide detector 42. Passive Radon Mitigation System- New Residential Construction 43. Slope of roof - show rise and run 44. Finish roof material - call out type of roofing and underlayment; 45. Roof sheathing - call out size; indicate if solid or spaced 46. Roof members - call out size; indicate if stick framed or trussed 47. Insulation baffle - 1 minimum clear vented air space above the insulation 48. Eave blocking/attic ventilation 49. Gutter and downspouts 50. Overhang - dimension 51. R values for foundation, wall, and attic insulation 52. Gypsum wall board - call out thickness 53. Floor - call out system. (example: 3/4 t&g plywood decking over 2 x 10 floor joist @ 16 o.c.) 54. Wall - call out system - (example: exterior - 1 x 8 bevel cedar siding over 1/2 plywood sheathing over 2 x 6 studs @ 16 o.c. with r-19 batt insulation on 1/2 gwb. interior - 2 x 4 studs @ 16 o.c. with 1/2 gwb each side.) 55. Dampproofing and waterproofing of foundation walls enclosing a room below 56. Foundation wall - indicate type of construction and size. 57. Floor To Floor, Floor to Top Plate - Minimum 7 0 ceiling height for IRC applications. 58. Garage Separation - Refer to Section R309.2 of the IRC. 5/8 type X GWB is used on ceilings below habitable space. Garage to house walls, and garage walls supporting habitable space above shall be protected with a least ½ inch GWB 59. Pressure Treated Sill - Call out size 60. Anchor Bolts - Call out size and spacing. 61. Reinforcing Bars (Rebar) - Call out size and spacing 62. Drain Tile Page 4 of 5

63. Grade - Show on elevations; and patios, decks - call out materials. Indicate distance of finished floor from grade. 64. Show existing structural foundations, framing and roofing on remodels and additions. Indicate openings such as windows and doors; and distinguish new from existing; a dashed line should indicate structures or items to be removed. F. Manufacturers specifications for Heating/cooling systems, Prefab Fireplaces, Hottubs and Pools (3 copies) Manufacturer s specifications and installation instructions are required to check for compliance with the requirements of the International Residential Code. Provide documentation indicating the appropriate HVAC equipment sizing and efficiency rating for whole house mechanical ventilation system. Provide documents confirming that all new heating and cooling equipment are sized in accordance with ACCA Manual S based on building loads, calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law. G. Shop Drawings for Specialty Items such as Trusses and Sprinkler Systems (3 copies) Shop drawings are drawings, diagrams, schedules, fabrication/installation drawings, erection, and other data specially prepared for the work by the Contractor or a Subcontractor, manufacturer, supplier or distributor to illustrate some portion of the work in greater detail than the working drawings provide. Shop drawings shall be prepared in accordance with current modern engineering practice and shall be of a size and scale to clearly show all necessary details. The purpose of the shop drawing submittal is to ensure that the products, materials, equipment, etc. provided are in compliance with code requirements and are coordinated with the rest of the project. H. Miscellaneous Energy Code Compliance: Plans and specifications must comply with the IRC energy requirements. If the exterior glazing area exceeds 15%, a ResCheck energy report must be submitted. For additions, include the floor plans of existing adjacent rooms. For second floor additions, verify existing foundation size and loading capacity. Provide engineering calculation and details for retaining walls four feet or higher. Provide engineering calculations and details for beams, joists, trusses, lateral loads that exceed the prescriptive tables in the IRC. Soil testing reports are required for New Single Family Homes. A soils engineer report is required to be provided at time of footing inspection for new homes built on tear down sites. The requirement for a soils engineer report at time of footing inspection shall be noted on the plans. An engineering analysis by an Architect or licensed Engineer may be required if poor soils are encountered. Additional engineered drawings, sections, details and structural plans may be required. A residential sprinkler system may be required if exposed engineered wood floor joists are used. The items detailed in this bulletin are required for a complete application. The information noted above is not all-inclusive of what may be required for a building permit application. Because each project and site are different, additional information may be requested during the application process. Page 5 of 5