WIND LOADS ON BALUSTRADES. Antonios W. Rofail a, Christian Mans a

Similar documents
THE PREDICTION OF WIND LOADS ON BUILDING ATTACHMENTS

PERFORMANCE OF AN AUXILIARY NATURAL VENTILATION SYSTEM

Benchmark Buildings for an International HFBB Comparison

Wind-induced Pressures on Patio Covers

Terrain classification and exposure factor in the 2005 National Building Code of Canada

DYNAMIC WIND LOADING OF H-SHAPED TALL BUILDINGS

PARAMETRIC CFD WIND FORCE ANALYSIS ON A RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC PANEL

Wind driven flow through building openings

American Residential Deck Railing Design Guide

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

Tall buildings. wind engineering & architectural aerodynamics. London Hong Kong Kuala Lumpur Abu Dhabi Dubai Shanghai Houston

Wind Pressures on Solar Panels Mounted on Residential Homes

Addition. Wind Loads on Rooftop Solar Panels , At a Glance Standard. Wind Loads on Rooftop Solar Panels

WIND FLOW IN THE RECESSED CAVITIES OF A TALL

FIRMLOK FLOORING SYSTEM DESIGN AND INSTALLATION MANUAL

RESILIENT INFRASTRUCTURE June 1 4, 2016

Multi-scale methodology to assess wind loads on building louvers

STRATEGIES FOR ADOPTING NEW TRENDS IN WIND LOAD EVALUATION ON STRUCTURES

Schöck Isokorb type DXT

WIND-DRIVEN RAIN ON THE WALLS OF BUILDINGS IN METRO VANCOUVER: PARAMETERS FOR RAIN PENETRATION TESTING

Designing for Natural Ventilation in Tall Residential Buildings

The Edge Protection Federation Containment Systems Product Specification, Test Methods

WIND LOADS ON BUILDINGS MWFRS (ENVELOPE PROCEDURE)

Schöck Isokorb Type CM

ABSTRACT. Assistant Professor, Brian M. Phillips (Chair) Professor, Bilal M. Ayyub, P.E. (Co-Chair) Dept. of Civil and Environmental Engineering

Vulnerability modelling of metal-clad industrial buildings to extreme wind loading

boundary layer wind flow. Measured wind pressures were expanded from limited measurement points to all the structural nodes using the orthonormal coor

TEST REPORT Juliet Balcony System - SKYFORCE

The Design and Engineering of Fabric Membrane Clad Buildings

PART R3-L ZONE, LOW DENSITY MULTIPLE DWELLING DISTRICT

2012 Wood Frame Construction Manual: Wind Speed and Design Pressure Determination According to ASCE 7 10

16.4 FLORIDA BUILDING CODE BUILDING

SAMPLE PROJECT IN WASHINGTON DC DOCUMENT NO. CALC LOADS AND LOAD COMBINATIONS 9 PROJECT ENGINEER. Pages REVISION TITLE

American Residential Deck Railing Design Guide

Wind loads at solar and photovoltaic modules for large plants

BOXSPAN RESIDENTIAL SPAN TABLES

PV-ezRack SolarRoof Longline Interface

SIMPLIFIED ESTIMATION OF CRITICAL TEMPERATURES OF PORTAL FRAMES IN FIRE

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

Wind Loads on Rooftop Solar Panel Systems: A Contribution to NBCC 2015

A study of single-sided ventilation and provision of balconies in the context of high-rise residential buildings

Investigation of the effect of balconies on natural ventilation of dwellings in high-rise residential buildings in subtropical climate

Bridge articulation No. 1.04

Photovoltaic (PV) Arrays

Wall Pressure Coefficients for Low- to High-Rise Buildings

STRUCTURAL CALCULATIONS

Schöck Isokorb type K

SECURE. UNIVERSAL. MOUNTING. Tilt Kit Installation Manual

Applications of computational wind engineering in the design of glass façades

Building Design Data

Local and overall wind pressure and force coefficients for solar panels

Wind-Induced Torsional Loads on Low- and Medium-Rise Buildings

WIND LOADS ON SOLAR PANEL SYSTEMS ATTACHED TO BUILDING ROOFS. Eleni Xypnitou. A Thesis. The Department. Building, Civil and Environmental Engineering

Wind Analogue or Digital?

Calculation of Wind Loads on Structures according to ASCE 7-10

JONES NICHOLSON PTY LTD CONSULTING ENGINEERS

Wind Tunnel Applications for Buildings

DEFINITIONS AND GENERAL EQUIREMENTS

10 April 10, 2013 Public Hearing APPLICANT AND PROPERTY OWNER: CHALICE CHRISTIAN CHURCH, INC.

Design Calculations Date: 27/04/2017

Schöck Isokorb type D

Doc No.:FAD17 (2224)C Draft INDIAN STANDARD IRRIGATION EQUIPMENT RAIN GUN SPRINKLER Specification PART 2 TEST METHOD FOR UNIFORMITY OF DISTRIBUTION

The HKIE Structural Examination Written Examination

Performance of the Acrylife Roof Vent

Wind Loads on a Medium-Rise Building by Using Five Major International Wind Codes and Standards

STRUCTURAL CALCULATIONS

STRUCTURAL CALCULATIONS

STRUCTURAL CALCULATIONS

Dr. K. R. C. Reddy 1, Sandip A. Tupat 2 1,2

2 Loads 2.1 BACKGROUND 2.2 DEAD LOADS

COMPUTATIONAL ANALYSIS ON THE EFFECTS OF FAÇADE MODIFICATIONS ON WIND-DRIVEN NATURAL VENTILATION PERFORMANCE OF A SINGLE-CELL ROOM

2012 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

This is an electronic reprint of the original article. This reprint may differ from the original in pagination and typographic detail.

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

TECHNICAL NOTE No.4 Simulated Windborne Debris Impact Testing of Building Envelope Components (Version 4 Published 10 January 2017)

RHINO-STOP Modular Vehicle Impact Barriers

STRUCTURAL DESIGN CERTIFICATE No: CSM SC Job No: 14S 391

PV-ezRack SolarRoof Klip-Lok Interface

Better Daylight and Natural Ventilation by Design

Technical Assignment 3 December 3, 2007

Schöck Isokorb Type CV

International Journal of Scientific & Engineering Research, Volume 7, Issue 6, June ISSN

TEST REPORT. Bushfire resistance test of an external wall system to BAL A40 in accordance with AS EWFA Report No:

Page 1 of 21

Stratford of Avon. Architectural Guidelines

STRUCTURAL DESIGN CRITERIA

ASCE 7-16: Changes to Wind Calculations for Rooftop Solar

Neighborhood Configurations and their Effect on Single-family Home Hurricane Wind Dynamics

AS/NZS 2: :2002 AS/NZS

Radiant Solar Tripod Planning and Installation Guide V1.2 With Australia AS/NZS1170.2

International Building Code 2009

Modelling of air pollution on urban buildings: a wind tunnel study

Full Paper Proc. of Int. Conf. on Advances in Civil Engineering 2012

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

Computer Aided Design of Modern High-Rise Building

Dynamic Time-history Analysis on Wind-induced Response of Light-weight Roof System

Effect of Wind and Structural Parameters on Wind-Induced Acceleration of RC Building

Load capacity of slender reinforced concrete walls governed by flexural cracking strength of concrete

Structural Calculations for standard BALCONY 1 system handrail using 55mm diameter posts (48.3mm x 5mm CHS) & 150 x 150 x 15mm base plates

Transcription:

WIND LOADS ON BALUSTRADES Antonios W. Rofail a, Christian Mans a a Windtech Consultants, 19 Willis Street, Wolli Creek, NSW, Australia ABSTRACT: This paper examines the wind loading on impermeable balustrade members. In particular, the study focuses on the net pressure coefficients measured across a balustrade member located on an isolated balcony. Comparisons are presented with existing code recommendations pertaining to the design loading on a balustrade member. Results suggest that the highest positive net pressure coefficient of 1.8Cp (acting in the direction towards the centre of the balcony) occurs on the upper corner balcony members, specifically the side wall balustrade located adjacent to the edge of the building. The highest negative net pressure coefficient of 1.6Cp occurs on balconies situated adjacent to the side edges of the building. For design, the current Australian, British and Hong Kong standards specify that balustrade members are required to withstand the larger of either the net wind loading acting across the balustrade or a 1kN/m 2 live load. For the recommended live load of 1kN/m 2 to dominate over the highest net pressure coefficient of 1.8Cp, the eaves height 3-sec gust wind speed is required to be less than 30m/s. For wind speeds greater than 30m/s, the wind loading coefficient of 1.8Cp dominates over the live loading. 1 INTRODUCTION Balustrade members are commonly found on low and high-rise residential apartment buildings. For design, the loading on a balustrade member is generally governed by either the worst design loading from wind pressures or from impact loading. For example, the current AS/NZS 1170.1-2002 [1] recommends that balustrades in private dwellings shall be designed to resist the worst loading from either the wind loading or a uniform loading of 1 kn/m 2 over the body of the balustrade. A similar live loading value is also recommended in the current British Standard and Hong Kong Building Regulations [2,3]. However, neither standard specifically specifies a method for determining the wind loading on the balustrade members. Assumptions must also be made regarding the application of pressure coefficients on the external and interior faces of the balustrade. This paper presents the findings of a comprehensive study aimed at quantifying the wind loading on impermeable balustrade members through wind tunnel testing. The results are compared with the existing live loading recommendations provided in the Australian Code. 2 EXPERIMENTAL PROCEDURE A variety of balustrade type and building configurations have been examined in this study. The focus of this study is to examine the wind loading on an isolated balcony located on both a low and highrise building. The wind tunnel testing incorporated a 1:50 scale model building with full-scale plan dimensions of 15m and 30m. Tests were repeated for two building heights, being 18m and 48m. The balustrade dimensions are defined as 3m long with a depth of 2m in full scale. The height of each balustrade wall is 1.2m with a slab depth of 0.15m. Tests were also repeated at two locations on the model, along the short building wall and along the long building wall for the 18m tall building. Tests on the 48m building were limited to the short build-

ing wall. Figure 1 shows photographs of the model identifying the two building geometries. The model was placed in atmospheric flow conditions that simulated a suburban terrain (AS/NZS 1170.2:2002, Terrain Category 3 [4]) and tested over 360 degrees at 15 degree increments. The mean wind speed and turbulence profiles as well as the normalized power spectral density in the wind tunnel matched the full-scale equivalent values for the terrain being modeled. a) Isolated balustrade, 18m tall bld b) Isolated balustrade, 48m tall bld Fig. 1. Photographs of the 1:50 scale model (H=18m and 48m) taken in the wind tunnel. As shown in Figure 1, balustrade members were placed over a single 15m by 15m section of the building. In total, 90 pressure taps were instrumented over nine balustrade members (i.e. 10 pressure taps for each balustrade). Of these, six pressure taps were positioned on the outer surface of the balustrade and four taps on the inner balustrade surface. As such, the positive pressures from the outer balustrade surface could be simultaneously combined with the negative pressures from the inner surface to determine the worst net loading acting across the balustrade member. Figure 2(a) presents the layout of the pressure taps used on the balustrade members. Pressure taps were positioned on nine balustrade members, labelled A through to I. In analyzing the pressure results, the balustrades were divided into three main zones: the top corner region (Balustrades A and C), the edge region (Balustrades B, D, F, G, I) and the mid-wall region (Balustrades E and H). Testing was performed in Windtech s Blockage Tolerant Boundary Layer Wind Tunnel. All pressures measured in the wind tunnel were initially referenced to the mean wind speed at a height located in low turbulence conditions situated well above the model. Pressures were sampled at 1024 samples per second for 64 seconds for the 1:50 model (2048 samples per second for 16 seconds for the 1:400 model). The pressure signal was later low-pass filtered at 500Hz and digital filtering was applied for the range 0 to 500Hz. Unless otherwise specified, all pressure coefficients presented in this paper are referenced to the 3-sec gust wind speed at eaves height, H.

Fig. 2. Pressure tap layout used in the study. (a) Test locations of Instrumented Panel (b) Layout of pressure tap locations measured directly on the balustrade. The symbol + represents taps positioned on the outer balustrade surface and the o symbol represents taps positioned on the inner balustrade surface 3 DISCUSSION Table 1 presents the peak positive and negative net pressure coefficients measured on the balustrade members on the 18m tall building, referenced to the 3-sec gust wind speed at roof height, H. A positive net coefficient is defined as acting in the direction towards the centre of the balcony. Conversely, a negative net coefficient is defined as acting away from the centre of the balcony. The coefficients are separated into three zones of the building surface: the top corner region, the edge region and the mid-wall region, as described in the preceding section. This is due to the unique flow characteristics expected to occur within the three regions. The results are further separated by examining the pressures measured on the side and main walls on each balcony. For example, the main balustrade wall is defined as running parallel to the building wall. The outer side wall represents the side balustrade wall adjacent to the edge of the building, while the inner side wall represents the side balustrade wall closest to the centre of the building. Regarding the positive net pressure coefficients, the results suggest that the largest loading occurred in the top corner region of the building for both sides of the building. The table also suggests the largest positive loading occurred on the outer side walls of the balconies, for winds approaching roughly perpendicular to the test section, with a largest pressure coefficient of 1.82. At this wind angle the side balcony walls are directly inline with the approaching flow, but are also within the region of separated flow at the corner of the building. Significant positive net pressure coefficients of up to 1.3 were also recorded on the edge balustrades, while a peak net positive coefficient of 0.71 was recorded on the centre balustrades.

The largest negative net pressure coefficients were recorded on the edge balustrade members, with a largest coefficient of -1.6. Again, this was recorded on the outer side wall of the balustrade. As the current wind loading standards do not provide any definitive recommendations for wind loading on balustrade members, comparisons with current live loading recommendations are presented. As defined by the current AS/NZS 1170.1 2002, balustrade walls are to be designed to withstand a net horizontal live loading of 1kN/m 2. A similar value is recommended by the current British Standard and the Hong Kong Building Regulations. Configuration Location C p max Corner Balcony Edge Balcony Midwall Balcony H=18m Short C p max 1.58 1.27 0.93 1.29 1.05 0.55 0.71 0.59 Face Tap A1 A6 C7 G1 D6 B7 E1 E7 θ 90 315 0 90 345 15 345 345 Long C p max 1.82 1.30 1.00 1.07 1.15 0.63 0.51 0.49 Face Tap C6 A6 A7 F6 B6 B7 E6 E7 θ 210 270 270 195 210 285 210 180 Configuration Location C p min Corner Balcony Edge Balcony Midwall Balcony H=18m Short C p min -0.57-0.59-0.45-1.24-1.03-0.56-1.31-0.6 Face Tap C1 C6 C7 I1 I6 I7 E1 E7 θ 75 0 300 0 105 285 90 75 Long C p min -0.81-0.61-0.65-1.59-0.78-0.66-1.16-0.63 Face Tap C6 C1 C7 G1 I1 G7 E1 E7 θ 180 0 180 285 60 285 90 285 Table 1. Summary of maximum and minimum net pressure coefficients recorded across balustrade members on the 18m building. Table 2 presents a summary of the net pressures recorded on the balustrade members for both the 18m and 48m tall buildings. For simplicity, the highest net pressures are presented, irrespective of whether loading occurred on the side or main balcony wall and irrespective of the direction of the net loading. Along with the worst net pressure coefficients, the table presents the equivalent eave height wind speeds required for the balustrade wind loading to dominate over the recommended 1kN/m 2 live load. Therefore, for design purposes, if the eave height wind speed exceeds that presented in Table 2, the balustrade should be designed according to the wind loading coefficients provided in Table 2. Conversely, if the eaves height wind speed is below that presented in Table 2, the balustrade member should be designed according to the 1kN/m 2 live loading. Regarding the isolated balustrade configuration, the table suggests that balustrades should be designed to withstand wind loading for an eaves height wind speed greater than 30m/s.

Building Height Balustrade Configuration Corner Edge Mid-wall Balcony Balcony Balcony H = 18m Isolated Balcony C p 1.82 1.59 1.31 H/B = 0.6 V H 3-sec gust (m/s) 30.1 32.2 35.5 H = 48m Isolated Balcony C p 1.65 1.75 1.56 H/B = 1.6 V H 3-sec gust (m/s) 31.6 30.7 32.5 Table 2. Summary of worst net pressure coefficients (+/-) measured across the balustrade members and the equivalent eaves height 3-sec gust wind speeds required to exceed the AS/NZS 1170.1:2002 recommended 1kN/m 2 live loading. 4 CONCLUSIONS A wind tunnel study was performed to directly measure the wind loading on balustrade members. Highest positive net peak pressure coefficients of up to 1.8, when referenced to the 3-sec gust wind speed at eaves height, were recorded on the top corner balconies. Highest negative net peak pressure coefficients of up to -1.6 were recorded on balconies adjacent to the edge of the building. The results suggest, for design purposes, balustrade members should be designed for wind loading if the 3-sec gust wind speed exceeds 30m/s, otherwise the balustrade may be designed for the 1kN/m 2 live load. 5 REFERENCES 1 AS/NZS 1170.1:2002, Structural Design Actions, Part 1: Permanent, Imposed and other Actions, Standards Australia, Homebush, 2002. 2 BS 6399-1:1996, Loading for buildings, Part 1: Code of practice for dead and imposed loads, British Standards Institution, London, 2002. 3 Building (Construction) Regulations, Chapter 123B: Imposed loads, Department of Justice, Hong Kong, 1991. 4 AS/NZS 1170.2:2002, Structural Design Actions, Part 2: Wind actions, Standards Australia, Homebush, 2002. 5 A. Rofail, Wind pressures on the cladding of building facades, MEng. Thesis, University of Sydney, Australia, 1991.