INTRODUCTION. Inspection Procedures oinitial Inspection Report. Visual Inspection Physical Sampling (Core and Slit Samples)

Similar documents
POLYURETHANE FOAM SAMPLE DESIGN GUIDELINE ACRYLIC

A. Supplier Qualifications: The ACRYSHIELD SPF Roofing System, as supplied by National Coatings Corporation, is approved for use on the project.

ERSYSTEMS ONESTEP PLUS

POLYURETHANE FOAM SAMPLE DESIGN GUIDELINES URETHANE

APPLICATION GUIDELINE Recoating Spray Foam Acrylic System

ROOFING APPLICATION STANDARD (RAS) No. 109

Acry-Tek 4200 / SPF System. Mod-Bit / BUR Surfaces

To ensure warranty eligibility, each job must be approved by American WeatherStar before it begins.

ROOFING APPLICATION STANDARD (RAS) No. 109

SPF Roof System Section Coated Foam Roofing

SOLAR COATING SYSTEMS ACRYLIC RENOVATION ROOF 4.5. Specification for Built-Up Roofing SUMMARY

Acry-Tek 4200 / SPF Recoat System

Section Energy Star & LEED Compliant SPF Roof System Roof System with Acrylic Coating, Aggregate & Cementitious Traffic Topping

A. Submit product data sheets and literature verifying fire ratings and physical properties of materials.

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

SOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY

Guideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing

Application Specification:

RECOMMENDED DESIGN SPECIFICATION

Acry-Tek 4200 / SPF System Metal Restoration

Guide Specification PART 1 - GENERAL Work Included. A. Preparation of Substrate, Inspections

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

Pol-E-Base Modified Bitumen Roof System

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

A. Submit product data sheets and literature verifying physical properties of materials.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES EVALUATION SUBJECT:

ACRYLIC. AGED (PVC, CPE, CPA) SINGLE-PLY (Thermoplastic) Membrane Restoration Sample Design Guideline

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

BAYBLOCK HT/BAYBLOCK HT BASE

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION

TOPCOAT System Specifications Corrugated Transite Panels

SUBMITTALS Descriptive literature: Submit manufacturer's application instructions and technical data sheets or catalog cuts on materials.

Fluid Applied All Acrylic Coating System Guide Specification Tropical Roofing Products-TPO/PVC 4.0G911. Built On The Principles of Quality & Integrity

SCOPE OF WORK PROJECT IDENTIFICATION

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

838 Coatings System Specification Single-Ply Restoration (838 SPR)

URETHANE. Asphalt Restoration Aged BUR and Modified Bitumen Sample Design Guideline

HAIL STUDY ON A 15 YEAR OLD SPRAYED POLYURETHANE FOAM (SPF) ROOFING SYSTEM

Hail Study on a 15 Year Old Sprayed Polyurethane Foam Roofing System

ROOF SUBSTRATE PREP MANUAL

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER GRAVEL SURFACE BUR

SMOOTH SURFACED BUILT-UP ROOFS WITH ARC SEBS REFLECTIVE ROOF COATINGS

403.XX Spray-Applied Fire Resistive Materials (SFRM). The bond strength of the SFRM shall be as follows:

STUDY GUIDE. For the REGISTERED ROOF OBSERVER (RRO ) EXAM. Prepared By RRO Examination Development Task Force

ASTEC Re-Ply Roof System for ASPHALT & MODIFIED BITUMEN ROOFS

ASTEC Re-Ply Roof System for ASPHALT & MODIFIED BITUMEN ROOFS

SECTION RESINOUS FLOORING PLEXIQUARTZ BROADCAST SKID-RESISTANT QUARTZ SYSTEM

Broadcast Parking Garage System

APPLICATION GUIDELINE

PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY

CIM IG 13 11/06. Instruction Guide

AGA Roof Deck Pavers. AGA Concrete Paver. Technical. Pavers: Hydraulically pressed concrete pavers: 460 tons of pressure.

ACRYLIC Elastek #127 Solar One Plus

PALISADE PD 40 SECTION SOLAR CONTROL FILMS. A. Optically clear Titanium Nitride ceramic sputtered polyester film for solar control.

Section Fluid-Applied Roofing. Modified Bitumen Roof Preservation System Master Guide Specification

Liquid Membrane Systems Product Guide

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

TOPCOAT Restoration Specifications Structural Concrete

PUF Roofing A Primer

ASTEC Re-Ply Roof System for AGED SINGLE PLY MEMBRANE (PVC, EPDM, THERMOPLASTIC) ROOFS

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC.

A. Submit product data sheets and literature verifying physical properties of materials.

St. Matthew United Methodist Church

Decorative Quartz Floor Coating System

CARLISLE DECK COATING INSTALLATION OVER EXISTING POLYURETHANE COATINGS

1/16 Single Broadcast Polymer Flooring System

Fluid Applied Silicone Coating System Guide Specification

Henry #1 CHOICE OF PROFESSIONALS

Fabric Reinforced System Section

SECTION LIGHTWEIGHT INSULATING CONCRETE

Technical Data Sheet NUKOTE SIL HS DESCRIPTION:

GE SCM3500 High Solids Silicone Roof Coating

TEN YEAR SPECIFICATION FOR SEALGUARD VFI-991 FLUID APPLIED SILICONE MEMBRANE FOR REHABILITATION OF LAPPED METAL ROOFS

RG-170 Elastomeric 15yr System/ Metal Roofs

Care & Preventative Maintenance Guide Liquid Applied Coatings and Roofing Systems 8/2016

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: COVESTRO, LLC

NIGHTSCAPE NS05 SECTION SOLAR CONTROL FILMS

CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES

Building Energy Efficiency Standards Mandatory measures minimum features that all buildings must have regardless of compliance method used.

BROADCAST KITCHEN FLOORING SYSTEM

System Specification CEM-DYE 25 SYSTEM Division 9 Finishes Section Staining and Transparent Finish

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Instruction Guide APPLICATION OF CIM TO CONCRETE

INSTALLATION GUIDE SPECIFICATION

MagnumStone Specifications Gravity

Application Specification:

GE SCM3500 High Solids Silicone Roof Coating

Section COATING RESTORATION

FireShield Restoration Specifications - EPDM

SECTION TOPSHIELD GUIDE SPECIFICATION SMOOTH AND GRANULE SURFACE ROOF RESTORATION TS-AC yr

UPRR INDUSTRIAL LEAD BRIDGE T-WALL RETAINING WALL SYSTEM 5.0 x 7.5 UNITS DESIGN UNIT 018 WORK PACKAGE 04

Application Specification:

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Henry #1 CHOICE OF PROFESSIONALS

BENEFITS & ADVANTAGES:

Application Specification:

Transcription:

INTRODUCTION Inspection Procedures oinitial Inspection Report Visual Inspection Physical Sampling (Core and Slit Samples)

ROOF INSPECTION PROCEDURES Occurs upon project completion Includes visual observation and physical sampling

PROJECT INFORMATION The following documents are to submitted with request for inspection 1. Project specific specifications 2. SPF and Coating product manufacturer s installation requirements

ROOF INSPECTION The objective of the roof inspection is to determine the individual applicator s ability to apply SPF as required by the individual project specifications and/or manufacturers requirements.

PROJECT INFORMATION

ROOF SKETCH The Roof Sketch shall include the following: Initial Diagram Visual Findings Physical Sampling

INITIAL ROOF DIAGRAM Initial diagram of roof oarrow indicating DUE NORTH oarrows indicating slope odetails : edges, expansion joints, etc. openetrations : drains, pipes, HVAC equip, skylights, etc. otake photos and note on drawing w/arrow.

INITIAL ROOF DIAGRAM EXAMPLE

VISUAL OBSERVATIONS DELAMINATED SUBSTRATE SPRAY POLYURETHANE FOAM COATING

FOAM CRACK CAUSED BY BUILDING SETTLEMENT

FOAM CRACK

FOAM CRACK AT ROOF EDGE

VISUAL INSPECTION VISUAL INSPECTION - FOAM FOAM BLISTERS WET FOAM PINHOLES SOFT FOAM EXPOSED FOAM SEPARATION FROM FLASHINGS MECHANICAL DAMAGE BIRD DAMAGE PONDING WATER

FOAM BLISTER

RUPTURED FOAM BLISTER

FOAM BLISTERS

WET FOAM AND PINHOLES

CHECK FOR SOFT FOAM THUMB TEST

EXPOSED FOAM

TREEBARK AND POPCORN FOAM TEXTURE

IMPROPER REPAIRS AND EXPOSED FOAM

EXPOSED FOAM

FOAM SEPARATED FROM GRAVEL STOP

IMPROPER DETAIL

IMPROPER DETAIL

MECHANICAL DAMAGE

MECHANICAL DAMAGE

BIRD DAMAGE

PONDING

COATING VISUAL INSPECTION COATING COATING BLISTERS POOR COATING ADHESION COATING CRACKS COATING RUNS PINHOLES

POOR COATING ADHESION

PINHOLES

POOR ACRYLIC COATING ADHESION

THIN COATING/EXPOSED FOAM

PHYSICAL SAMPLING involves destructive investigation and is necessary to ensure that the spray polyurethane foam roofing system has been applied according to the project and/or manufacturer s specification.

PHYSICAL SAMPLING CORE SAMPLES MIN 2 PER ROOF UP TO 10,000 SQ. FT. AND 1 CORE FOR EACH 10,000 SQUARE FEET OVER 10,000 SQ. FT. USE APPROPRIATE CORING DEVICE 2 DIAMETER MINIMUM

CORE SAMPLES CORE SAMPLES MEASURE TOTAL FOAM THICKNESS EXAMINE FOR: NUMBER OF LIFTS THICKNESS OF LIFTS ADHESION SUBSTRATE TO FOAM FOAM TO FOAM FOAM TO COATING COATING TO COATING

CORE SAMPLES OTHER OBSERVATIONS SOFT/SPONGY FOAM MOISTURE UV DEGRADATION BETWEEN LIFTS DIFFERENCE IN COLOR OF LIFTS COATING OR OTHER MATERIALS

CORE TESTING Cores will be measured and weighed to determine the unit weight in accordance with ASTM D1621. Unit weight will be reported in pounds per cubic foot (pcf) Cores will be measured and tested in compression in accordance with ASTM D1622. The compressive strength of the cores will be reported in pounds per square inch (psi)

MEASURE CORE

WEIGH CORE SAMPLE

COMPRESSIVE STRENGTH TESTING

CORE TEST RESULTS

SLIT SAMPLES SLIT SAMPLES OBTAIN SAMPLES FROM THE FOLLOWING: FIELD OF THE ROOF PASS LINES PARAPET WALL/ROOF EDGE (AT LEAST ONE SAMPLE) DEFECTS MINIMUM 3 PER 10,000 SQ. FT. SIZE 1/2 WIDE 2-3 LENGTH 3/4 DEPTH

SLIT SAMPLE EXAMINE SLITS IMMEDIATELY FOR COATING THICKNESS IF COATING IS THIN: TAKE ADDITIONAL SLITS IN A 5 RADIUS IN ALL 4 DIRECTIONS IF STILL THIN, ADDITIONAL SLITS IN A 10 RADIUS OR UNTIL ADEQUATE COATING THICKNESS IS FOUND MEASURE TOTAL FOAM DEPTH

2 TO 3 ¾" SLIT SAMPLE

MEASURE FOAM THICKNESS

OPTICAL COMPARATOR AND SLIT

SLIT AT BLISTER DEGRADATION OF FOAM

ROOF SKETCH INFORMATION PHYSICAL SAMPLING LOCATIONS LOCATE CORE SAMPLE LOCATIONS ON ROOF SKETCH LOCATE SLIT SAMPLE LOCATIONS ON ROOF SKETCH

SLIT SAMPLE REPORTING

FINAL ROOF SKETCH

REPORT The final report will typically include the following: Project Information Name and Location Materials Information Manufacturer s material numbers and lot numbers Deviations observed during inspection Core and Slit sample information Drawing

GOOD WORKMANSHIP

QUESTIONS