CONDUITS AND FITTINGS

Similar documents
CHAPTER 11 CONDUITS AND FITTINGS

HANDHOLES, PULLING VAULTS AND JUNCTION BOXES

CHAPTER 12 HANDHOLES, PULLING VAULTS, AND JUNCTION BOXES

New Conduit Specification

CHAPTER 13 GROUNDING AND BONDING

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS

TS 803 DUCTS DUCT INSTALLATION, PROTECTION AND MARKING WITHIN A TRENCH OPEN TRENCH DUCT INSTALLATION PROFILE

OKLAHOMA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR BRIDGE NAVIGATION LIGHTING

3. Intermediate metal conduit (IMC). 4. Electric metallic tubing (EMT). 5. Flexible metal conduit (FLEX). 6. Polyvinyl chloride conduit (PVC).

1/5/2018 WHAT S NEW SINCE B & B QUALIFICATION OF WORKERS. What's New Since SPEC BOOK 2018 SPEC BOOK 2018 SPEC BOOK

12/21/2018 WHAT S NEW SINCE What's New Since SPEC BOOK 2018 SPEC BOOK 2018 SPEC BOOK WHAT S NEW SINCE 2014

Section 2: Underground

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF DUCTS

SECTION UNDERGROUND ELECTRICAL CONSTRUCTION

SPECIAL SPECIFICATION 6623 Multi-Duct Conduit System

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.

WIRING METHODS CHAPTER 38

SECTION CONDUITS AND BOXES PART 1- GENERAL. A. Work covered by this section includes the furnishing and installation of conduits and boxes.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF DUCTS

Please check with your local inspection authority for any additional requirements before installation.

If a new residence s electrical service is not located within 200 feet of existing

DEPARTMENT OF TRANSPORTATION STATE OF GEORGIA SPECIAL PROVISION. Section 550 Storm Drain Pipe, Pipe-Arch Culverts, and Side Drain Pipe

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF DUCTS

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF DUCTS

SPECIAL SPECIFICATION 6664 Level (3) Communications System

CITY OF UNION, OREGON TECHNICAL SPECIFICATIONS SECTION 9 UNDERGROUND UTILITIES

SPECIAL SPECIFICATION 6658 Time Warner Communications System

A. Section Includes: Electrical site utilities and coordination of requirements with the utility company and service specifications.

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL

Youngstown State University

Merrimac Municipal Light Department. Commercial Developments Policy

YAKIMA COUNTY, WASHINGTON. Special Provisions For Water Main Construction

UNIVERSITY OF MISSOURI Hydronic Energy Distribution 2016 Q1

TS 804 CABLES TABLE OF CONTENTS TRAFFIC SIGNAL EQUIPMENT POLE WIRING DIAGRAM LOCATIONS WITH CENTRE MEDIANS

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service.

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

B. Provide a complete conduit system with associated couplings, connectors, and fittings.

A. This section is intended to provide design guidelines for Utility Direct Buried Piping and Conduit Systems.

CONSTRUCTION SPECIFICATION FOR TRAFFIC ACTUATION EQUIPMENT

DMS CONDUIT EFFECTIVE DATE: APRIL

CONSTRUCTION SPECIFICATION FOR GROUNDING

Student Services & Classroom Addition

SECTION ELECTRICAL SITE UTILITIES

SECTION A. Underwriters Laboratories, Inc., listed and NEC approved

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS

CW 3620 INSTALLATION OF UNDERGROUND TRAFFIC SIGNAL SERVICES TABLE OF CONTENTS

Specifications Electrical Metallic Tubing (EMT)

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11

SANITARY WASTE AND VENT PIPING

UNDERGROUND SERVICES - GENERAL SERVICE AND MULTI-UNIT RESIDENTIAL

PART 7 COMMUNICATIONS, LIGHTING, TRAFFIC CONTROL, POWER

SUPPLEMENTARY SECTION: STANDARD SPECIFICATIONS PAGE 1 STORMWATER MAINS & CULVERTS MAY 2018

Huntsville Utilities Underground Residential Service Requirements

DIVISION 26 - ELECTRICAL Section Conduit for Electrical Systems 1. GENERAL 1.1 WORK INCLUDES

SECTION UNDERGROUND ELECTRICAL CONSTRUCTION

Section 7: Specifications

SECTION CONDUIT AND FITTINGS

DIVISION 1100 TRAFFIC

A. Bellcore CAO-8546 Specification for Type B, C, and D Plastic Conduit. B. NEMA TC 6& PVC Plastic Utilities Duct for Underground Installation.

CITY OF FARGO SPECIFICATIONS SEWER AND WATER SERVICE CONNECTIONS

DIVISION 32 EXTERIOR IMPROVEMENTS IRRIGATION

H. Underground Transmission System Design

ITEM NO. 824 SERVICE SUPPLY LINES (WATER)

Material will comply with those standards as established by UL or NEMA and shall be commercial grade. All materials will be new and free from defects.

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL

CITY OF OCEANSIDE. Electrical Lines, Plumbing and Mechanical Burial & Support Requirements. Informational Bulletin

San Antonio Water System Standard Specifications for Construction ITEM NO. 824 SERVICE SUPPLY LINES (WATER)

GLENWOOD PLACE 2 MAR 2015

Electric Service Standards

SECTION ELECTRICAL UTILITY SERVICES

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

SECTION PATHWAYS FOR ELECTRONIC SAFETY AND SECURITY

DIVISION 32 EXTERIOR IMPROVEMENTS IRRIGATION

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

Specifications Rigid Metal Conduit / PVC Coated Rigid Metal Conduit

UNDERGROUND SERVICES SECONDARY

SPECIAL SPECIFICATION 6666 Charter Communications System

CONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION

Special Specification 6016 Intelligent Transportation System (ITS) Multi-Duct Conduit

Welcome to Douglas County PUD

GENERAL NOTES PEDERNALES ELECTRIC COOPERATIVE, INC. RESIDENTIAL AND COMMERCIAL AMP METER LOOP SPECIFICATIONS

SECTION 1 GENERAL NOTES

CITY OF GARDEN PLAIN, KANSAS STANDARDS AND SPECIFICATIONS FOR GAS YARD LINES & METER SETS

SECTION CONDUITS AND BOXES

HITT STREET UNIVERSITY PROJECT #: CP REFER TO CP PLANS FOR ELECTRICAL DUCTBANK IN HITT STREET INSTALL:

SECTION ELECTRICAL CABLE. 1. Trench excavation, backfill, and compaction; Section

UNIVERSITY OF MISSOURI Electrical Manholes and Handholes 2016 Q1

UNM IT/Telecommunications Guide Specification Communications Underground Ducts, Raceways and Structures /27/06

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

Specifications for Electrical Underground Residential Distribution Systems

DRINKING WATER LINE INSTALLATION STANDARDS

SECTION CONDUIT AND BOXES

ITEM 432 TUNNEL CONSTRUCTION

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ELECTRICAL CHAMBERS

STANDARD SPECIFICATIONS

ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

Transcription:

CONDUIT AND FITTINGS Rigid Steel Conduit 3801 Rigid PVC Conduit 3803 HDPE Conduit 3803 Flexible Non Metallic Liquid Tight Conduit Type LFNC-B 3804 PVC Coated Urethane Lined Galvanized Rigid Steel Conduit 3805 11-1

GENERAL A conduit is defined as a tube or duct for enclosing electrical wires or cables. MnDOT uses two types of conduits in signal construction: Rigid Steel Conduit - Specification 3801. Non-Metallic Conduit - Specification 3803. MnDOT allows the use of either Rigid Polyvinyl Chloride (PVC) conduit (rigid sectional lengths) or High Density Polyethylene (HDPE) (continuous length) conduit. All Rigid PVC and HDPE conduit and fittings must be listed by a Nationally Recognized Testing Laboratory (NRTL). See Contract Documents for the specific requirements for all non-metallic conduits. Lighting plans will indicate the size of conduit to be used in the construction of a lighting system and the following are the typical sizes of conduit used: Median Barrier: 1-1/2 inch rigid polyvinyl chloride (PVC) conduit Under traveled roadway: 4 inch rigid polyvinyl chloride (PVC) conduit, or high density poly ethylene (HDPE) conduit marking each end with red locator ball (See Chapter 11 for locator ball). Bridges: 1-1/2 inch rigid steel conduit (RSC) and retaining walls: 1-1/2 inch rigid polyvinyl chloride (PVC) conduit or as specified in the Contract Documents. The material for all conduit bushing grounding lugs used on RSC conduit must consist of stainless steel, brass, copper or bronze with lay in ground lugs. Transformer to Source of Power (SOP): 2 inch rigid steel conduit (RSC) or as specified in the Contract Documents. All rigid polyvinyl chloride (PVC) conduits must be Schedule 80. Underground conduit runs must have provisions for drainage of moisture. Horizontal conduit runs must be sloped to drain at a rate of not less than 0.25 percent, and all low points must be drained. At the low points (not at the open ends of conduit runs) a standard tee conduit fitting must be installed and a nipple at least 6 inches long must be extended into a hole approximately 2 feet square by 2 feet deep and backfilled with crushed rock or approved granular material. Liquid Tight Flexible Non-Metallic Conduit (LFNC-B) - Specification 3804. MnDOT uses PVC Coated RSC on bridges. Installation requirements are covered in 2565.3D PVC Coated Hot Dipped Galvanized Rigid Steel Conduit - Specification 3805. MnDOT uses PVC Coated RSC on bridges. Installation requirements are covered in 2565.3D 11-2

CONDUIT AND FITTINGS STANDARD SPECIFICATIONS All conduits and fittings must be the size and type specified in the Contract Documents. If conduit size is not specified, the minimum conduit size must be 3/4 inch (21 millimeters). Conduit installation must be in accordance with the National Electrical Code. The conduit in a run must be the same size and type and must be continuous from outlet to outlet. Conduit must be installed in as straight a run as practicable and will enter handhole and foundations in line with the general direction of the conduit run. Conduits with sharp kinks or reduced cross section will be rejected. Damage may occur when: a. The conduit is bent without using the proper equipment. b. An attempt is made to relocate the end of the conduit without proper excavation and the conduit is forced so that it lines up with the handhole or foundation. Damaged Conduit CONDUIT BENDS 2565.3D Conduit bends other than those done in the factory must have a radius no less than 6 times the normal diameter of the conduit. Bends must not damage the conduit or effectively reduce its internal diameter. In addition bends must not exceed 360 degrees of bend per conduit run between handholes or foundations. Refer to the NEC 344.26 or 352.26 for requirements. 344.26 Bends Number in One Run. There shall not be more than the equivalent of four quarter bends (360 degrees total) between pull points, for example, conduit bodies and boxes. 11-3

ABOVE GROUND 2565.3D All cables must be run in conduits except as otherwise specified in the Contract Documents. When conduits are attached to wood poles the conduit must be secured with the appropriate two hole type conduit straps that meet the current edition of the National Electrical Code (NEC). The conduit straps must not be more than 4 feet (1.2 meters) apart and the conduit must be supported within 3 feet (900 millimeters) of the termination point or fitting. Conduits attached to metal poles require a minimum of 3/4 inch (19 millimeters) stainless steel bindings that are spaced not more than 5 feet (1.5 meters) apart. Conduits attached to other structures must be secured as indicated in the Contract Documents to the satisfaction of the Engineer. UNDERGROUND 2565.3D Underground conduits must be placed no less than 18 inches (460 millimeters) below the surface of any ground area and not less than 24 inches (610 millimeters) below any roadway surface. It should be noted that the depth of the conduit is measured from the top of the pipe. For example a trench for a 4 inch (100 millimeters) conduit is 22 inches (560 millimeters) from the finished ground to the bottom of the trench. 11-4

CONDUIT AND FITTINGS Conduits placed under railroad tracks must be placed no less than 57 inches (1.44 meters) below the bottom of the ties or as required by the railroad company. For Rigid Steel Conduit (RSC) and Rigid Polyvinyl Chloride (PVC) conduit trenching is the accepted method of conduit installation except when the conduits are being installed under existing roadways. Conduits must not be placed until the trench has been inspected. Except for under existing pavements, High Density Polyethylene (HDPE) (continuous length) conduit must be placed by trenching, vibratory plow with feed blade or directional boring. 11-5

If installing conduit under an existing roadway using a method other than directional boring and a distortion in excess of one quarter-inch (6 mm) is created in the existing roadway surface due to conduit installation the Contractor must remove the distortion and restore at no expense to the Department the roadway surface to its original condition. If boring operations through a roadbed are abandoned for any reason, the voids must be grouted at the Contractor s expense and to the satisfaction of the Engineer. Direct buried lighting cable must be installed in rigid PVC or HDPE conduit under paved surfaces. 2545.3G.2 Install direct buried lighting cable in rigid PVC or HDPE conduit if located under bituminous, concrete, or other material not considered a top soil. Provide 3 in conduit if the contract does not specify size of conduit. For handholes used on lighting systems the Contractor must install a 36 inch (91.44cm) rigid PVC conduit stub out with the appropriate end bell for all direct buried lighting cable entering a hand hole. 11-6

CONDUIT AND FITTINGS Position conduit terminating in handholes, concrete foundations and equipment pads so the conduit extends inside the handholes, pole bases, structure bases, or service cabinets as indicated in the Standard Plates or Plan details. Slope the conduit away from the foundation and toward the handhole opening for drainage. Conduits that are stubbed out of the foundation for future use must extend 18 inches to 24 inches (460 millimeters to 610 millimeters) beyond the foundation or sidewalk in the direction specified by the Engineer, and capped on both ends with standard pipe caps. After the cap is secured, a permanent marker should be used to draw an arrow, on the cap, indicating the direction of the conduit. 11-7

OPEN ENDS 2565.3D The open ends of conduits that are located in handholes or those that extend above foundations must be capped until the wiring is installed. Due to some confusion with regards to rigid PVC conduit ends MnDOT has defined the ends as follows. 2545.1C and 2565.1C. Bell End End Bell When the RSC caps are removed a threaded insulated grounding bushing with lay in ground lug for RSC (UL Std. 467) must be installed and be compatible with a solid bare No. 6 copper bonding conductor. The lug material shall consist of stainless steel, copper, brass or bronze. Each bushing must be covered with a corrosion inhibiting compound. See 2545.3.R and 2565.3.D.4.b 11-8

CONDUIT AND FITTINGS The open ends of conduits in a cabinet or foundation must be sealed in accordance with 2565.3D.2.b. After the installation of the cables and conductors use a duct seal compound NRTL classified under general use tapes. This prevents moisture from entering the cabinet or pole. The sealant also helps in preventing rodents from entering the foundation through the conduit system. This requirement applies to both signals and lighting systems. R.S.C. JOINTS 2565.3D When standard length RSC conduit is cut the end must be threaded and reamed to remove burrs and rough edges. Field cuts must be made square and true so that all ends joined by coupling butt together for the full circumference. This provides an electrical bonding and grounding connection throughout the entire length of the conduit run. If the galvanized coating on the conduit is damaged during handling or installation, the damaged areas must be painted with MnDOT approved paint to the satisfaction of the Engineer. 11-9

EXISTING CONDUITS 2565.3D If the existing underground conduit is incorporated into a new traffic control signal system it must be cleaned and blown out with compressed air before the new wires are installed. If a new handhole is installed into an existing conduit run the conduit must be cut, threaded and extended into the new handhole as directed by the Engineer. A new bushing with an integral lug and ground wire must be installed and the sides of the handhole must be made water tight before the installation of any new wires. Thread less couplings and bushings are not permitted unless otherwise authorized by the Engineer. 11-10

CONDUIT AND FITTINGS NON-METALLIC CONDUITS 2565.3D [Rigid PVC Sectional and Continuous Length (HDPE)] Rigid PVC Conduit HDPE Continuous Length Conduit All non-metallic conduits must be listed by a Nationally Recognized Testing Laboratory (NRTL) as being compliant with the requirements of UL 514B and UL 651 for underground use. All non-metallic conduits must be Schedule 80. Cut ends of sectional conduit must butt or come together for the full circumference thereof. All non-metallic conduit must be either RED or Grey color. HDPE continuous length conduit must not be spliced under roadway surfaces. When rigid PVC conduit sections are installed using the directional boring method the rigid PVC conduit sections must be pre-glued at least 6 hours prior to installation under roadway surfaces. Long-line couplings must be used when rigid PVC conduit sections are installed under roadway surfaces. The Contractor must trim the inside and outside of cut ends to remove rough edges. 11-11

All open ends of non-metallic conduit must be immediately capped to keep moisture and debris out. Before cables and conductors are installed, standard non-metallic conduit end bells must be installed to prevent damage to the cables and conductors. The Contractor must pull cables and conductors through the non-metallic conduit in such a manner as not to damage the conduit due to pull rope abrasion. The Contractor will be required to pull a ground wire through the conduit system as required by the Contract Documents. HDPE Continuous length conduit must not be used between concrete foundations and the nearest handhole. EXPANSION and DEFLECTION/EXPANSION FITTINGS for CONDUIT USED ON BRIDGES 2565.3D.7 & 3839 Expansion Fitting Deflection/Expansion Fitting Because bridges are subjected to flexing, expansion and contraction, special PVC coated expansion and expansion/deflection conduit fittings as well as hangers are required. Improper installation of conduits can cause severe damage to the electrical system and may cause damage to the bridge structure itself. The Expansion fitting provides 8 inches of linear movement. The Deflection/Expansion fitting provides ¾ of an inch of movement in any direction. All conduits must be attached to bridge as specified in the Contract Documents. Repair of damaged PVC coating shall be made in accordance with the conduit manufacturer s repair requirements. 11-12