Code Compliance Research Report CCRR 0241

EMPIRE SHAKE, EMPIRE PLUS SHAKE, AND EMPIRE SLATE POLYOLEFIN COMPOSITE TILES

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

ATI Evaluation Service A Division of Architectural Testing Certification Services Code Compliance Research Report

ATI Evaluation Service A Division of Architectural Testing Certification Services

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: TEJAS BORJA USA EVALUATION SUBJECT:

LISTING INFORMATION OF Epilay - Superior, Ultra and Platinum Roofing Underlayments SPEC ID: Epilay Inc S. Main Street, E1 unit C

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES REPORT HOLDER: TEFUTE BUILDING MATERIALS COMPANY, LLC

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services PCA-125

Code Compliance Research Report CCRR-0164

Code Compliance Research Report CCRR-0205

ATI Evaluation Service A Division of Architectural Testing Certification Services

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOF PANELS REPORT HOLDER: ONDULINE NORTH AMERICA, INC. EVALUATION SUBJECT:

ATI-ES Code Compliance Research Report

ATI Evaluation Service A Division of Architectural Testing Certification Services

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131

Code Compliance Research Report CCRR-0153

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

ATI Evaluation Service A Division of Architectural Testing Certification Services

Originally Issued: 03/27/2015 Revised: 10/17/2017 Valid Through: 03/31/2018

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: ENVIRONMENTALLY SAFE PRODUCTS, INC.

ATI-ES Code Compliance Research Report

Originally Issued: 09/19/2014 Revised: 10/17/2017 Valid Through: 11/15/2017

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BARTILE ROOFS, INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

Code Compliance Research Report CCRR-0194

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

ATI Evaluation Service A Division of Architectural Testing Certification Services

ICC-ES Report OR-4, AND MOISTURE DIVISION: SECTION: SECTION: Reissued 11/2017 This. Report Holder:

ESR-2015P* Reissued April 2014 This report is subject to renewal April 1, 2015.

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

Code Compliance Research Report CCRR-0266

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: RIDGE VENTS REPORT HOLDER: VERSCENE, INC.

Code Compliance Research Report CCRR 0270

REPORT HOLDER: FEROOF CO., LTD SEONWON LI SEONNAM MYEON SUNGJU GUN KYEONGSANGBUK DO SOUTH KOREA EVALUATION SUBJECT:

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

Code Compliance Research Report CCRR-0106

Code Compliance Research Report CCRR-0185

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: CERAMICA LA ESCANDELLA, S.A.

Originally Issued: 09/10/2015 Revised: 10/12/2017 Valid Through: 09/30/2019

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FACED PANELS REPORT HOLDER: MEXALIT INDUSTRIAL, S.A. DE C.V.

UL Evaluation Report UL ER Issued: May 31, Revised: June 6, UL Category Code: ULEZ. CSI MasterFormat

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY

ATI Evaluation Service A Division of Architectural Testing Certification Services #0774

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

Engineering Services Program

ICC-ES Evaluation Report. ESR-3297 Reissued March 1, 2013 This report is subject to renewal May 1, 2014.

ATI Evaluation Service A Division of Architectural Testing Certification Services

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0100

Code Compliance Research Report CCRR-0234

Code Compliance Research Report CCRR-0131

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: BORAL ROOFING LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: DERBY BUILDING PRODUCTS INCORPORATED

Code Compliance Research Report CCRR-0187

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: ROOF PANELS REPORT HOLDER: ROSER CO., LTD.

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

Code Compliance Research Report CCRR-0186

ZARA & ASSOCIATES, INC. Peter L. Zara 8435 Sunrise Lake Blvd -# Sunrise, Florida Phone

Code Compliance Research Report CCRR-0118

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF TILES REPORT HOLDER: GERARD ROOFING TECHNOLOGIES EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: ASSOCIATED MATERIALS, INC.

Code Compliance Research Report CCRR-0114

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION

Code Compliance Research Report CCRR-0176

Code Compliance Research Report CCRR-0137

ESR-3284 Reissued August 1, 2011 This report is subject to renewal August 1, 2013.

FLORIDA PRODUCT APPROVAL GULFRIBTM FLORIDA PRODUCT APPROVAL NO R2. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

SECTION COMPOSITE ROOF TILE SYSTEMS

Prepared for: Thompson Architectural Metals Company, Inc E. Hillsborough Avenue Tampa, FL 33605

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BORAL ROOFING EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.

Code Compliance Research Report CCRR 0277

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

Code Compliance Research Report CCRR-0208

Code Compliance Research Report CCRR-0101

CBUCK Engineering. Wood Deck

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: KMEW CO., LTD. EVALUATION SUBJECT:

Transcription:

ATI Evaluation Service A Division of Architectural Testing Certification Services PCA-125 Subject to Renewal: 01/18/2018 Issued: 01/27/2017 Visit www.ati-es.com for current status Page 1 of 7 INSPIRE ROOFING PRODUCTS 4057 S. Oak Street Metamora, MI 48455 (800) 971-4148 www.tapcoint.com 1.0 Subject Inspire Arcella Shake Inspire Aledora Slate 2.0 Research Scope 2.1. Building Codes: 2015 International Building Code (IBC 2015 International Residential Code (IRC) 2014 Florida Building Code (FBC) (Excluding HVHZ - High Velocity Hurricane Zones) 2.2. Properties: Weather Resistance Wind Resistance Durability Fire Classification 3.0 Description 3.1. Uses The Inspire Arcella Shakes and Inspire Aledora Slate are used as a Class A or Class C roof covering when installed according to the manufacturer s instructions and this report. See Section 5.0 and Figure 3. 3.2. Materials The Inspire Arcella Shakes and Inspire Aledora Slates are injection molded polypropylene simulated cedar shake and slate roof tiles. 3.2.1. The shakes are manufactured with a nominal length of 24 inches and widths of 5 inches, 7.5 inches, and 10 inches. See Figure 1. The slate tiles are manufactured with a nominal length of 18 inches and widths of 6 inches, 8 inches, 10 inches and 12 inches. See Figures 4, 5, 6, and 7. 3.2.2. Starter shakes and slate are nominally 14 inches in height and 12 inches wide. See Figure 2 and Figure 8. 3.2.3. Hip and ridge shakes are nominally 24 inches in length and 12 inches wide. Hip and ridge shakes are provided with a preformed pitch along the length of the shake. Hip and ridge slates are nominally 18 inches in length and 12 inches wide. See Figure 2 and Figure 8. 3.3. Fasteners shall be a minimum 10 gauge, 0.134 inch by 1.5 inch stainless steel roofing nails. 4.0 Performance Characteristics 4.1. Fire Classification The Inspire Arcella Shake and Aledora Slate are classified as a Class A roof covering for combustible decks in accordance with IBC Section 1505.2 and IRC R902.1 when used in conjunction with one layer of MB Technologies Layfast SBS TU35 underlayment, as recognized in ICC-ES Evaluation Report ESR-2799 and UL TBFU.R11080. See Section 5.1 for underlayment installation. The Inspire Arcella Shakes and Aledora Slates are classified as a Class C roof covering for combustible decks in accordance with IBC Section 1505.4 and IRC R902.1 when used in conjunction with one layer of ASTM D 226 Type II compliant underlayment. See Section 5.1 for underlayment installation. 4.2. Wind Resistance Inspire Arcella Shakes and Aledora Slates installed in accordance with this report are limited to installation in areas where the maximum basic wind speed is 100 mph on structures with a mean roof height of 40 feet in Exposure B areas. Inspire Arcella Shakes and Aledora Slates installed in accordance with this report are classified as Class 90 in accordance with UL 580. 5.0 Installation Installation shall be in accordance with the requirements of the applicable code, the manufacturer's installation instructions, and this report. Where differences occur between this report and the manufacturer's installation instructions, this report shall govern. 5.1. Inspire Arcella Shakes and Aledora Slates are recognized as a Class A roof covering when installed in conjunction with one layer of MB Technologies Layfast SBS TU35 underlayment, at a maximum shake exposure of 10.25 inches and maximum slate exposure of 8 inches. Installation of the underlayment shall be in

accordance with the requirements of the applicable code and ICC-ES ESR-2799. Inspire Arcella Shakes and Aledora Slates are recognized as a Class C roof covering when installed in conjunction with one layer of ASTM D 226 Type II underlayment, at a maximum shake exposure of 10.25 inches and slate exposure of 8 inches. 5.2. Inspire Arcella Shakes and Inspire Aledora Slates may be installed over a solid sheathed roof or a spaced sheathing installation at a minimum roof slope of 3:12. Sheathing shall comply with DOC PS 1, DOC PS 2, or ANSI/APA PRP 210. 5.2.1. For nominal 1 x 6 inch sheathing plank spaced sheathing is as follows: Arcella Shake may be used in a maximum spacing of 10.25 inches o.c., and Aledora Slate may be used in maximum spacing of 8 inches o.c. 5.2.2. The 12 inch wide starters are installed at the eave-line with a minimum of two fasteners, as described in Section 3.3. See Figure 3. 5.2.3. The first row of shakes or slates is installed on top of the starter shakes and must be attached with a minimum of two fasteners, as described in Section 3.3. Subsequent rows of shakes are installed with a maximum exposure of 10.25 inches and slates at a maximum exposure of 8 inches. See Figure 3. 5.2.4. Hip and ridge shakes or slate are installed with a minimum of two fasteners, as described in Section 3.3, with the exception of the fastener lengths. At a minimum, fasteners must penetrate sheathing 0.75 inches. Hip and ridge shakes and slates are installed with a maximum exposure of 8 inches. 5.3. Ice Barrier - In areas where there has been a history of ice forming along the eaves causing a backup of water, an ice barrier that consists of at least two layers of underlayment cemented together shall be used and extend from the lowest edges of all roof surfaces to a point at least 24 inches inside the exterior wall line of the building. 5.4. Flashing and edge materials shall meet the minimum requirements of IBC Section 1503.2 or IRC Section R903.2, where applicable. 6.0 Supporting Evidence 6.1. Manufacturer's drawings and installation instructions. Page 2 of 7 6.2. Reports of fire tests of roof coverings in accordance with ASTM E 108-07a, Standard Test Methods for Fire Tests of Roof Coverings. 6.3. Reports of uplift resistance in accordance with UL 580-06 Tests for Uplift Resistance of Roof Assemblies. 6.4. Documentation of an Intertek approved quality control system for the manufacturing of products recognized in this report. 6.5. Reports of testing and engineering analysis demonstrating compliance with ICC-ES AC07, Acceptance Criteria for Special Roofing Systems, approved February 2014. 7.0 Conditions of Use Inspire Arcella Shakes and Aledora Slate applications identified in this report are deemed to comply with the intent of the provisions of the referenced building codes subject to the following conditions: 7.1. Installation of MB Technologies Layfast SBS TU35 roof underlayment shall be in accordance with ICC-ES ESR-2799. The recognition of MB Technologies Layfast SBS TU35 roof underlayment as an approved element of the Inspire Arcella Shakes and Aledora Slate roof covering is contingent on the maintenance of a valid ICC-ES ESR-2799 report and UL listing TGFU.R11080. 7.2. Inspire Arcella Shakes and Aledora Slate in this report are manufactured in Metamora, Michigan by Inspire Roofing Products under an approved quality control system with inspections by Architectural Testing (IAS AA-676). 8.0 Identification Each bundle of Inspire Arcella Shakes and Aledora Slate produced in accordance with this report shall be packaged and labeled with the following information: 8.1. Name of the report holder; 8.2. The statement: "ASTM E 108 Classified See ATI at www.ati-es.com"; 8.3. The statement "Install on solid or spaced sheathing, min. slope 3:12" 8.4. Each shake and slate is embossed with the Architectural Testing Code Compliance Research Report mark and number ().

9.0 Use 9.1. Approval of building products and/or materials can only be granted by a building official having legal authority in the specific jurisdiction where approval is sought. 9.2. s shall not be used in any manner that implies an endorsement of the product or manufacturer by Architectural Testing. Page 3 of 7 9.3. Reference to the Architectural Testing internet web site address at www.ati-es.com is recommended to ascertain the current version and status of this report. Figure 1 Inspire Arcella Shakes (5", 7.5", or 10" wide) Figure 2 Starters, Hip, and Ridge Shakes

Page 4 of 7 Figure 3 Inspire Arcella Shakes Installation (See Section 5.3 for ice barrier requirement)

Page 5 of 7 Figure 4 Aledora Slate - 12 Width Figure 5 Aledora Slate - 10 Width

Page 6 of 7 Figure 6 Aledora Slate - 8 Width Figure 7 Aledora Slate - 6 Width

Page 7 of 7 Figure 8 Starters, Hip, and Ridge Slates Figure 9 Aledora Slate Installation with Class C Underlayment (Note that Class A installation requires use of MB Technologies Layfast SBS TU35 Underlayment)