DIVISION: METALS SECTION: STRUCTURAL STEEL FRAMING REPORT HOLDER: CAST CONNEX CORPORATION

Similar documents
ICC-ES Evaluation Report Issued November 1, 2011 This report is subject to renewal November 1, 2012.

DIVISION: METALS SECTION: STRUCTURAL STEEL FRAMING REPORT HOLDER: SEISMIC STRUCTURAL DESIGN ASSOCIATES, INC.

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: PEIKKO GROUP, INC.

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: AKRON PRODUCTS COMPANY

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: PJ S REBAR INC.

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: SRL INDUSTRIES LTD.

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER:

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES REPORT HOLDER: NELSON STUD WELDING, INC WEST RIDGE ROAD ELYRIA, OHIO 44036

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: MITEK USA, INC.

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: EVALUATION SUBJECT:

DIVISION: METALS SECTION: COLD FORMED METAL FRAMING REPORT HOLDER: AEGIS METAL FRAMING, A MITEK COMPANY

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: TENDON SYSTEMS, LLC

LEGACY REPORT DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-FABRICATED WOOD TRUSSES REPORT HOLDER: EAGLE METAL PRODUCTS

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS LLC

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: BARSPLICE PRODUCTS INC WEBSTER STREET DAYTON, OHIO

SECTION STRUCTURAL STEEL

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: SAS STRESSTEEL INC. 100 NEW DUTCH LANE FAIRFIELD, NEW JERSEY 07004

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

Originally Issued: 09/28/2017 Valid Through: 09/30/2018

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: BOSTITCH FASTENING SYSTEMS

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: GEOTECH ENTERPRISES, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: MITEK USA, INC.

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: POST-TENSIONED CONCRETE REPORT HOLDER: PRECISION-HAYES INTERNATIONAL

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: DEXTRA MANUFACTURING CO., LTD. EVALUATION SUBJECT:

REPORT HOLDER: ispan SYSTEMS LP 70 BRENTWOOD DRIVE PRINCETON, ONTARIO N0J 1V0 CANADA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 100 PLANO, TEXAS 75024

REPORT HOLDER: LOOS & CO., INC. 901 INDUSTRIAL BOULEVARD NAPLES, FLORIDA EVALUATION SUBJECT:

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: SPLICE SLEEVE JAPAN, LTD.

Trusted ICC ES HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: LINDAPTER

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: MMFX TECHNOLOGIES A COMMERCIAL METALS COMPANY

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: DEXTRA MANUFACTURING CO., LTD.

Insulating Cellular Concrete Steel Joists Painting. A. America Society for Testing and Materials (ASTM):

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW VELOCITY X-U AND X-U 15 UNIVERSAL FASTENERS AND X-P CONCRETE FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC. EVALUATION SUBJECT:

SPECIAL PROVISION FOR STRUCTURAL STEEL AND ALUMINUM CONSTRUCTION. C&T:SJC 1 of 10 C&T:APPR:DAJ:DBP: FHWA:APPR:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: APPLIED FIREPROOFING REPORT HOLDER: FLAMEOFF COATINGS, INC. EVALUATION SUBJECT:

REPORT HOLDER: JAACO CORPORATION NE 68 TH STREET, SUITE C 130 REDMOND, WASHINGTON EVALUATION SUBJECT:

REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

CONSTRUCTION SPECIFICATION FOR STRUCTURAL STEEL

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

Report of Special Inspections

Table of Contents Page No.

DIVISION: CONCRETE SECTION: POST-TENSIONED CONCRETE REPORT HOLDER: GENERAL TECHNOLOGIES, INC.

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL FLOOR DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER:

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: ULTRALOX 2955 LONE OAK DRIVE, SUITE 180 EAGAN, MINNESOTA 55121

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: KWIK BOLT TZ MASONRY ANCHORS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: ITW BUILDING COMPONENTS GROUP INC.

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: LNA SOLUTIONS A KEE SAFETY LOGISTIC LTD

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMARTVENT PRODUCTS, INC.

DIVISION: METALS SECTION: COLD FORMED METAL FRAMING REPORT HOLDER: AEGIS METAL FRAMING, A DIVISION OF MITEK

REPORT HOLDER: CALIFORNIA EXPANDED METAL PRODUCTS COMPANY (CEMCO) CROSSROADS PARKWAY NORTH, SUITE 325 CITY OF INDUSTRY, CALIFORNIA 91746

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: CPG INTERNATIONAL LLC DBA THE AZEK COMPANY LLC EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: SPECIALTY PLACED CONCRETE REPORT HOLDER: EMMEDUE S.P.A.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: PASLODE, AN ILLINOIS TOOL WORKS COMPANY

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC.

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: KINGSPAN LIGHT + AIR LLC

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: SKYCO SKYLIGHTS 2995 AIRWAY AVENUE, SUITE B COSTA MESA, CALIFORNIA 92626

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: STARK TRUSS COMPANY, INC.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED STRUCTURAL WOOD REPORT HOLDER: SWEET S JOISTS, INC.

Joint Evaluation Report ICC-ES (800) (562)

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER:

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

Joint Evaluation Report

SECTION METAL WELDING

AASHTO/AWS D1.5M/D1.5:2008. Table of Contents

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

EXAMPLE STATEMENT OF SPECIAL INSPECTIONS (SSI)

Joint Evaluation Report

Transcription:

0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3031 Reissued 12/2017 This report is subject to renewal 12/2019. DIVISION: 05 00 00 METALS SECTION: 05 12 00 STRUCTURAL STEEL FRAMING REPORT HOLDER: CAST CONNEX CORPORATION 366 ADELAIDE STREET EAST, SUITE 425 TORONTO, ONTARIO M5A 3X9 CANADA EVALUATION SUBJECT: CAST CONNEX HIGH STRENGTH CONNECTORS Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report ESR-3031 Reissued December 2017 This report is subject to renewal December 2019. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION: 05 00 00 METALS Section: 05 12 00 Structural Steel Framing REPORT HOLDER: CAST CONNEX CORPORATION 366 ADELAIDE STREET EAST, SUITE 425 TORONTO, ONTARIO M5A 3X9 CANADA (416) 806-3521 www.castconnex.com info@castconnex.com EVALUATION SUBJECT CAST CONNEX HIGH-STRENGTH CONNECTORS 1.0 EVALUATION SCOPE Compliance with the following codes: 2009 International Building Code (IBC) 2006 International Building Code (IBC) Properties evaluated: Structural 2.0 USES Cast ConneX High-Strength Connectors are used as steel brace to gusset plate connections in seismicresistant steel concentrically braced frame construction. The connectors are also used in non-seismic structural applications as connectors for structural steel elements loaded predominantly in tension and/or compression. 3.0 DESCRIPTION 3.1 General: Cast ConneX High-Strength Connectors provide brace to gusset plate connections for use in Special Steel Concentrically Braced Frame (SCBF) and Ordinary Steel Concentrically Braced Frame (OCBF) systems as defined in the AISC Seismic Provisions. The connectors are configured as a single-piece element with two parallel flat plates at one end, which transition to a single circular shape at the opposite end. The circular end includes a preparation which forms a 60-degree groove angle between the wall of the round HSS or pipe when mated to the connector. Five connector sizes are available, which are coordinated to fit the outer diameter of standard round hollow structural section (HSS) or pipe sections used to construct the brace: Model HSC-102, for 4-inch-outside-diameter (102 mm) HSS and pipe; Model HSC-141 for 5 9 / 16 -inch-outside-diameter (141 mm) HSS and pipe; Model HSC-168 for 6⅝-inchoutside-diameter (168 mm) HSS and pipe; Model HSC-219 for 8⅝-inch-outside-diameter (219 mm) HSS and pipe; and Model HSC-273 for 10¾-inch-outsidediameter (273 mm) HSS and pipe. The connectors must be shop-welded by a registered and approved fabricator to round HSS or pipe brace elements using complete joint penetration (CJP) groove welds; and the resulting brace-connector assembly must be field-bolted or fieldwelded to single gusset plates connected to the beamcolumn intersections of a structural steel frame at each end of the brace-connector assembly. The flat plates of the connectors must be prepared with holes by the registered and approved fabricator to allow for bolted connections. Illustrative details are provided in Figures 1, 2, and 3. 3.2 Materials: 3.2.1 Cast ConneX High-Strength Connectors : The proprietary connectors are produced by Cast Connex Corporation from cast steel complying with ASTM A958 Grade SC 8620 Class 80/50, including supplementary requirements set forth in Appendix A of ANSI/AISC 358-05s1-09 and additional requirements in the approved quality documentation. The minimum strength properties are F y = 50 ksi (345 MPa) and F u = 80 ksi (552 MPa). 3.2.2 Structural Shapes: Structural steel shapes that must be used in conjunction with Cast ConneX High- Strength Connectors include round hollow structural sections (HSS) conforming to ASTM A500 Grade B or C, and ASTM A501; and pipe conforming to ASTM A53. The HSS and pipe must also comply with requirements in Section 8.2b and either Section13.2 or Section 14.2 of ANSI/AISC 341-05 (ANSI/AISC 341) for SCBFs or OCBFs, respectively. 3.2.3 Welds: The welded joint between a Cast ConneX High-Strength Connector and the connected HSS or pipe brace member must provide complete joint penetration (CJP). When the brace connector assembly is to be field-welded to the gusset plate rather than fieldbolted, the connection between a Cast ConneX High- Strength Connector and the gusset plate must be made using fillet welds. All welded joints must comply with the requirements stipulated in ANSI/AISC 360-05 (ANSI/AISC 360) and ANSI/AWS D1.1-2004 (ANSI/AWS D1.1). For structures located in Seismic Design Category D, E, or F, welded joints must additionally ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 6

ESR-3031 Most Widely Accepted and Trusted Page 2 of 6 comply with requirements stipulated in ANSI/AISC 341 and ANSI/AWS D1.8-2005 (ANSI/AWS D1.8) for demand-critical welded connections. Weld filler metal must comply with Charpy V-Notch (CVN) toughness requirements set forth in Section 7.3, Appendix W and Appendix X of ANSI/AISC 341. As the cast steel material of the connectors is not prequalified as set forth in Chapter 3 of ANSI/AWS D1.1 and heat treatment may include quenching and tempering, welds must be qualified by procedure qualification records in accordance with Chapter 4 of ANSI/AWS D1.1. 3.2.4 Bolts: The high-strength bolts used between the gusset plate must comply with ASTM A325, ASTM F1852 or ASTM A490. 3.2.5 Structural Plates: The structural steel material used for the gusset plates must comply with Section A3 of ANSI/AISC 360. For structures assigned to Seismic Design Category D, E, or F, the structural steel material must also comply with Sections 6 and 8.2 of ANSI/AISC 341 and additional requirements, depending on whether the joint is bolted or welded, as set forth in Section 7 of ANSI/AISC 341. 4.0 DESIGN AND INSTALLATION 4.1 SCBF or OCBF System Design: The structural design procedures must be in accordance with Chapters 16 and 22 of the 2009 IBC or 2006 IBC as Load and Resistance Factor or Allowable Stress Design. The design procedures must also be in accordance with ANSI/AISC 360 and the 2013 Cast ConneX High- Strength Connector Design Guide, 2nd edition. As set forth in IBC Section 2205.2, when used as a portion of the seismic load resisting system in Seismic Design Category D, E, or F, seismic design and detailing must comply with ASCE/SEI 7-05 and ANSI/AISC 341. The connector must be considered to be within a protected zone and subject to provisions of Sections 7.4 and 13.6 of ANSI/AISC 341. 4.2 Brace Connection Design: The connections must be designed and detailed in accordance with ANSI/AISC 341 when the assemblage is a portion of a seismic load resisting system, or ANSI/AISC 360 for non-seismically loaded applications. When used to create an SCBF or OCBF in Seismic Design Category D, E, or F, the connections must develop the required strength in accordance with ANSI/AISC 341, Section 13 or Section 14, respectively. The SCBF design must also comply with the requirements for the exception listed in ANSI/AISC 341, Section 13.3b, as illustrated in Figure 3, or alternatively provide a rationale for using an alternative design and detailing method to ensure that the plastic hinge at a brace end forms within the gusset plate and not within the connector, the connection between the connector and the gusset plate, nor within the brace. The welded joint between a Cast ConneX High- Strength Connector and the connected hollow section brace member must provide complete joint penetration (CJP). When the brace-connector assembly is to be fieldbolted to the gusset plate, the bolted joint between the gusset plate must be designed in accordance with ANSI/AISC 360. For structures located in Seismic Design Category D, E, or F, design must also comply with Section 7.2 of ANSI/AISC 341 using pretensioned high-strength bolts in joints with slip-critical faying surfaces conforming to Class A or Class B requirements. When the brace connector assembly is to be fieldwelded to the gusset plate, the connection between a gusset plate must be made using fillet welds. The design must comply with ANSI/AWS D1.1 with the modifications in ANSI/AISC 360. 4.3 Fabrication and Erection: The welded joint between a Cast ConneX High- Strength Connector and the connected HSS or pipe brace member must provide complete joint penetration (CJP), and this welding operation must be performed in the shop of a registered and approved fabricator. A Welding Procedure Specification (WPS), prepared in accordance with Clause 4 of ANSI/AWS D.1 and Section 1704.3.1, Table 1704.3 and Section 1708 of the IBC, must be developed by the steel fabricator for each base steel type, welding position, weld type, welding process, electrode manufacturer, and filler metal trade name for the electrode type selected; and for all essential variable changes set forth in Clause 7.7 of ANSI/AWS D1.1 in the Procedure Qualification Record (PQR) that exceed allowable tolerances. For structures assigned to Seismic Design Categories D, E, and F, the WPS must also comply with supplemental requirements in Clause 6.1 of ANSI/AWS D1.8 and Section 18 and Appendix Q of ANSI/AISC 341. Each WPS must be qualified in accordance with a documented PQR in accordance with Clause 4 of ANSI/AWS D1.1. Table 1 provides a suggested test WPS for performing PQR, and the related WPS for production, assuming the test WPS is used. Erection must be in conformance with ANSI/AISC 303-05, Section 7, and must be consistent with the requirements noted in Chapter 22 of the IBC. The brace connector assembly s connection to the gusset plate using either welds or bolts must be made either at an approved fabricator s shop or at the jobsite by the erector. 4.4 Quality Assurance: 4.4.1 Cast ConneX High-Strength Connectors : Non-destructive testing must be conducted by the manufacturer s qualified inspectors. The procedures for qualification of inspectors must be in accordance with American Society for Nondestructive Testing, Inc. (ASNT), TC-1A or an equivalent standard as set forth in the manufacturer s approved quality documentation. Applicable testing requirements include the following: 4.4.1.1 Tensile Requirements: Tensile tests must be performed for each heat in accordance with ASTM A370 and ASTM A781, and show compliance with requirements for the cast steel grade in accordance with ASTM A958 Grade SC8620 Class 80/50. 4.4.1.2 Charpy V-Notch (CVN) Requirements: CVN testing must be performed for each heat in accordance with ASTM A370 and ASTM A781. Three notched specimens must be tested with the first heat, and with each subsequent 20th ton (18 100 kg) of finished material. The specimens must have a minimum CVN toughness of 20 ft-lb (27 J) at 70 F (21 C). 4.4.1.3 Non-destructive Testing (NDT) of Castings: 4.4.1.3.1 Procedures: Radiographic testing (RT) as set forth in the approved quality documentation is conducted according to the procedures prescribed in ASTM E446

ESR-3031 Most Widely Accepted and Trusted Page 3 of 6 and ASTM E186, with an acceptance of Level III or better. Ultrasonic testing (UT) as set forth in the approved quality documentation is conducted according to the procedures set forth in ASTM A609 Procedure A, with an acceptance of Level 3 or better. Magnetic particle testing (MT) as set forth in the approved quality documentation is conducted according to the procedures prescribed by ASTM E709 with an acceptance of Level III or better in accordance with ASTM A903. Visual inspection as set forth in the approved quality documentation must be performed in accordance with ASTM A802, with an acceptance of Level I. 4.4.1.3.2 Required NDT: First Article: The first article is defined as the first production casting made from a permanently mounted and rigged pattern. First Article Inspection (FAI) must be performed on the first casting produced from each pattern. The first article casting dimensions must be measured and recorded. FAI must include RT and MT. 4.4.1.3.3 Production Castings: UT, MT, and visual inspection must be performed on 100 percent of the casting production. 4.4.1.4 Weld Repair Procedures: Production castings with discontinuities that exceed the requirements of Section 4.4.1.3 of this report must be weld-repaired. Weld-repair of castings must be performed in accordance with ASTM A488. The same testing method that discovered the discontinuities must be repeated on repaired castings to confirm the removal of all discontinuities that exceed the requirements of Section 4.4.1.3 of this report. 4.4.2 Fabrication and Installation of Brace Connector Assemblies: 4.4.2.1 Fabrication of Brace to Connector Assemblies: Cast ConneX High-Strength Connectors are supplied by Cast Connex Corporation. Fabrication of brace connector assemblies must be performed by a registered and approved fabricator. The approved fabricator must comply with Section 1704.2.2 of the IBC. For structures assigned to Seismic Design Category C, D, E or F, visual inspection and nondestructive testing (NDT) in accordance with Sections 1704 and 1707 of the IBC must be performed. A visual inspection and testing program must be established by the registered design professional and must include the following items, at a minimum: a. Visual and Ultrasonic testing of Complete Joint Penetration (CJP) groove welds between the Cast ConneX High-Strength Connector and the round HSS or Pipe brace element in accordance with Appendix Q, Section Q5, of ANSI/AISC 341. This inspection and testing is to be conducted at the shop of the fabricator. b. Qualification of NDT personnel, and compliance with ANSI/AWS D1.1 Clause 6.14.6 and ASTM E164, as appropriate. 4.4.2.2 Jobsite: The approved construction documents for each project must include a written quality assurance program, which, at a minimum, must include the following: A statement of special inspection complying with IBC Sections 1705, 1706, and 1707 must be included in the structural design drawings and specifications prepared by the registered design professional. Special inspection provisions for steel construction must comply with Sections 1704.2, 1704.3 and 1707.2 of the IBC and Part 1, Section 18 and Appendix Q of ANSI/AISC 341, and must be included in the statement of special inspection. Special inspection must verify compliance of steel with specifications, steel identification, and identification of high-strength bolts, nuts, washers, if applicable, in accordance with IBC Section 2203 and the approved construction documents. When the brace connector assembly is to be fieldbolted to the gusset plates, inspection of high-strength bolt installation must comply with IBC Section 1704.3.3 and Appendix Q, Section Q5.3, of ANSI/AISC-341. When the brace connector assembly is to be fieldwelded to the gusset plates, special inspection must verify weld filler metal compliance with specifications, weld filler metal identification, qualification of welders, use of appropriate welding materials, storage conditions for welding materials, welded joint preparations, conformance of welding procedures with applicable ANSI/AISC 341 and ANSI/AWS D1.1 requirements, and fabrication tolerances. For structures assigned to Seismic Design Categories C, D, E and F (IBC or ASCE/SEI 7), visual inspection and non-destructive testing (NDT) in accordance with Sections 1704 and 1707 of the IBC must be performed. A visual inspection and testing program must be established by the registered design professional in the statement of special inspection and must include the following items, at a minimum: Visual inspection of all fillet welds between the gusset plate in accordance with Appendix Q, Section Q5, of ANSI/AISC 341. Qualification of NDT personnel, and compliance with ANSI/AWS D1.1 Clause 6.14.6 and ASTM E164, as appropriate. 5.0 CONDITIONS OF USE: The Cast ConneX High-Strength Connectors described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Connection design must be in accordance with this report, the applicable code, and the Cast ConneX High-Strength Connector Design Guide, and must be prepared by a registered design professional. 5.2 Structural design drawings and specifications, shop drawings, and erection drawings must comply with Section A4 of ANSI/AISC 360 and Section 5 of ANSI/AISC 341. 5.3 Fabrication and erection of brace connector assemblies must comply with Sections 4.3 and 4.4 of this report and the Cast ConneX High-Strength Connector Design Guide, and must either be done by a fabricator approved by the building official, as set forth in Section 1704.2.2 of the IBC, or must be under special inspection as set forth in Section 1704 of the IBC. 5.4 Quality assurance must be provided in accordance with Section 4.4 of this report. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Cast ConneX High-Strength Connectors for Use

ESR-3031 Most Widely Accepted and Trusted Page 4 of 6 as Bracing Connections in Accordance with AISC 341 Sections 13.3 and 14.4 (AC427), dated October 2011. 7.0 IDENTIFICATION Each Cast ConneX High-Strength Connector as described in this report is identified by raised markings on the connector that show the manufacturer s logo (a stylized X ); the connector name in metric diameter size [for example, HSC-168 corresponds to a Cast ConneX High-Strength Connector accommodating hollow section elements of 6 5 / 8 inches (168 mm) outer diameter]; and a serial number which provides traceability to heat number, chemical and physical analysis reports, and reports of non-destructive testing. Product labeling includes the report holder s name, the manufacturer s name and address, the evaluation report number (ESR-3031) and the name of the inspection agency (ICC-ES LLC). RECOMMENDATIONS FOR PQR ASTM A958 SC8620 80/50 to ASTM A500 grade B Thickness: 5 / 16 " Weld type: TYK single bevel CJP groove weld (see AWS D1.1:2010 Figure 3.8 and 3.9, Detail A) Position: test both 2G and 5G TABLE 1 SUGGESTED TEST WPS FOR PERFORMING PQR RECOMMENDATIONS FOR WPS (see ANSI/AWS D1.1:2010 Tables 3.6, and 4.5) 5 / 32 " to 5 / 8 " all Root Opening: 1 / 8 " +/- 1 / 16 " ( 1 / 16 " 3 / 16 ") Groove Angle: 60 degrees + 10, - 5 degrees (55 70 degrees) Process: FCAW-G Filler Metal Manufacturer: Lincoln Electric Co. Product Name: UltraCore 71A85 Classification(s): E71T-1M-H8, E71T -9M-H8 Diameter: 0.045" Shielding Gas: 80% Argon, balance CO2 75-85% Argon, balance CO2 Shielding Gas Flow Rate: 45 CFH + 30%, - 20% (36 58 CFH) Current and Polarity: DC+ Output: CV Contact Tube to Work Distance: 1" +/- 1 / 4 " ( 3 / 4 " 1 1 / 4 ") Voltage: 26 V +/- 7% (24.2 27.8 V) Amperage: 190 A +/- 10% (171 209 A) Wire Feed Speed: 350 ipm +/- 10% (315 385 ipm) Travel Speed: 6 ipm +/- 25% (5.5 7.5 ipm) Heat Input: + 0, - 20 kj/inch (29 49 kj/inch) (Voltage * Amperage * 0.06 / Travel Speed) = 49 kj/inch minimum preheat: 225F Measured PQR preheat and interpass temperatures maximum preheat and interpass temperature: 400F + not to exceed maximum interpass temperature - 25 degrees Notes: For the physical properties and bend tests of the completed weld, plate testing similar to Figure 4.11 of ANSI/AWS D1.1:2010, with a 60 degree single bevel groove weld shall be conducted. The test plates for the ASTM A958 SC8620 80/50 material can be supplied by Cast Connex Corporation. For the ASTM A500 material, the test plates shall be cut from the flat side of a large box tube of the same specification and grade of steel being used for the brace (for round HSS braces), or of a flattened section of cut pipe wall.

ESR-3031 Most Widely Accepted and Trusted Page 5 of 6 FIGURE 1 CAST CONNEX HIGH-STRENGTH CONNECTOR FIGURE 2 CAST CONNEX HIGH-STRENGTH CONNECTOR SHOWN IN FIELD-BOLTED CONFIGURATION IN BRACED FRAME

ESR-3031 Most Widely Accepted and Trusted Page 6 of 6 FIGURE 3 GUSSET PLATE DETAILING IN SCBF TO ACCOMMODATE OUT-OF-PLANE INELASTIC DEFORMATION OF BRACE FOR VARIOUS BRACING ANGLES