Seasonal variations in physico-chemical characteristics of ground water collected from Kondapalli nearby VTPS-Vijayawada

Similar documents
EPA Primary. (mg/l as CaCO3) (mg/l as CaCO3)

RECOMMENDED SCOPE OF ACCREDITATION (For Testing Laboratories) * Test Method / Standard against which tests are performed

CERTIFICATE OF ANALYSIS

KKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana

Prakruti Environmental Engineers (Environmental Laboratory), 1, Utkanth Society, B/H Alkapuri Club, Alkapuri, Vadodara, Gujarat

Quality Evaluation of Drinking Waters of Rural Water Supplies (RWS) in West Godavari region of Andhra Pradesh

Journal of Chemical and Pharmaceutical Research, 2012, 4(2): Research Article

Indian Standard DRINKING WATER SPECIFICATION (Second Revision)

Assessment of Water Quality of Three Different Aquatic Environments Over Three Seasons

QUESTIONNAIRE FOR GENERAL WTP REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : groundwater (well pit); urban wastewater;

Lake Huron Water Treatment Plant Mineral Report

EVALUATION OF SURFACE DRINKING WATER SOURCES OF DEHRADUN USING MULTIVARIATE ANALYSIS

Lake Huron Water Treatment Plant Mineral Report

MECON LIMITED RANCHI , INDIA

Detroit Water and Sewerage Department Water Quality Division Laboratory Analysis of Water Samples Collected at Lake Huron Plant 10/14/2014

Detroit Water and Sewerage Department Water Quality Division Laboratory Analysis of Water Samples Collected at Lake Huron Plant 6/9/2015

Superintendence Company of India Private Limited, Plot Y-23, Block-EP, Sector-V, Salt Lake City, Kolkata, West Bengal

Tolerance and Classification

Correlation Study on Physico-Chemical Parameters and Quality Assessment of Kosi River Water, Uttarakhand

Environmental Science

Water quality analysis of Disposal site and its adjacent area of Guwahati, Assam, India

Ground water quality has emerged as one

MECON LIMITED RANCHI , INDIA

CERTIFICATE OF ANALYSIS

Analysis of Drinking Water Parameters of Groundwater Samplesin Jeelugumilli Mandal, AP, India

Lecture 1: Introduction

Assessment of Groundwater Quality in and around Neyveli Lignite Mines using GIS and Water Quality Index, Cuddalore District, Tamil Nadu

Assessment of Ground Water Quality in and around Gobichettipalayam Town Erode District, Tamilnadu

GLOBAL TECH. ENVIRO EXPERTS PVT. LTD. (FORMERLY GLOBAL EXPERTS) An ISO-9001:2008 Certified Company

Madhya Pradesh Waste Management Project Laboratory, Plot No. 104, Industrial Area No. II, Pithampur, Dhar, Madhya Pradesh

ASSESSMENT OF PHYSICO-CHEMICAL QUALITY OF MUNICIPAL WATER SAMPLES OF MAKRONIA SUB-URBAN AREA OF BUNDEL KHAND REGION, INDIA

Study on potability of water from Abna river at Nimar region of Madhya Pradesh

Nichrome Testing Laboratory and Research Private Limited, No nd Main, German Hospital Road, Narayanpur, Dharwad, Karnataka

Investigation on Physico-Chemical Analysis of Ground Water around Polyfibre Industry Harihara, India

CHARACTERIZATION OF TEXTILE WASTEWATER

D. METHODOLOGY AND WORK-PLAN STUDY AREA

2. GUIDELINES FOR THE EVALUATION OF DRINKING-WATER QUALITY FOR HUMAN CONSUMPTION WITH REGARD TO CHEMICAL, PHYSICAL AND BACTERIOLOGICAL QUALITY

Discipline Chemical Testing Issue Date Certificate Number T-3553 Valid Until Last Amended on - Page 1 of 9

Warm Mineral Springs Sampling by Sarasota County

Influence of a Chemical Industry Effluent on Water Quality of GobindBallabh Pant Sagar A Long Term Study

CERTIFICATE OF ANALYSIS REVISED REPORT

Journal of Chemical and Pharmaceutical Research

ASSESSMENT OF WATER QUALITY INDEX FOR GROUNDWATER OF VALSAD DISTRICT OF SOUTH GUJARAT (INDIA) P. Shroff and R. T. Vashi*

INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCES Volume 2, No 2, Copyright 2010 All rights reserved Integrated Publishing Association

Groundwater Suitability for Drinking and Agricultural usage in MIDC Area Chakan, Pune

ANALYSIS AND MAPPING OF GROUND WATER QUALITY OF BHAUNAK RIVER BASIN OF JALGAON (MS) DISTRICT USING ARC-GIS

Discipline Chemical Testing Issue Date Certificate Number T-3617 Valid Until Last Amended on

Drinking Water Supply and

Assessment of Physico-chemical Status of Groundwater Samples of Dholpur District, Rajasthan, India

SWANA 2017 Leachate Basics and Quality Changes with Organics Removal. Steve Johnson M.Eng., P.Eng.

Physico-chemical analysis of ground water taken from five blocks (Udwantnagar, Tarari, Charpokhar, Piro, Sahar) of southern Bhojpur (Bihar)

SCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS

Journal of Chemical and Pharmaceutical Research, 2012, 4(3): Research Article

IMPACT OF CEMENT INDUSTRY ON THE GROUND WATER QUALITY A CASE STUDY

French Creek Well # 2 Water Analysis Behind 1221 Ormonde Road

Annex 7.1 National Ambient Air Quality Standards for Nepal, 2003

EVALUATION OF WATER QUALITY: PHYSICO-CHEMICAL PARAMETERS AT DHAMOLA RIVER FROM DIFFERENT SOURCES OF SAHARANPUR CITY

WATER QUALITY INDEX (WQI) OF RIVER TAPTI-SURAT, GUJARAT-INDIA

Seasonal and Environmental Pollution Impact on the Quality of Water of River Poonch near District Kotli, Pakistan

International Journal of Advance Engineering and Research Development EFFECT OF NEARBY CITIES ON WATER QUALITY OF CHAMBAL RIVER

Water Quality Index For Assessment Of Water Quality In South Chennai Coastal Aquifer, Tamil Nadu, India

Appendix C: Water Quality Data

Accreditation No: LAB 067. SGS Chemical, Environmental & Microbiological Lab Lahore, Pakistan

ENVIPRO Laboratories, 2nd Floor, Sy. No. 63/4, Site No. 5, P&T Layout Road, Ashwath Nagar, Srigandhada Kaval, Sunkadakatte, Bangalore, Karnataka

Physico-Chemical Analysis of Public Well Water Samples of some of the Villages of Dhule Tahsil District Dhule (M.S) India

A Physico Chemical Study of Ground Water from Few Selected Areas of Secunderabad in Telangana State

Hydro-chemical Survey of Groundwater of Delhi, India

INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCES Volume 1, No 6, Copyright 2010 All rights reserved Integrated Publishing Association

TITLE: SABS PROFICIENCY TESTING SCHEME, RSA

TREATMENT OF PARBOILED RICE MANUFACTURING WASTEWATER USING ANAEROBIC FIXED FILM FIXED BED REACTOR PACKED WITH SPECIAL MEDIA

Schedule of Accreditation

STUDIES ON THE PHYSICO CHEMICAL ANALYSES OF TWO DIFFERENT WATER BODIES

Effect of Industrial Effluents on Surface Water Quality - A Case Study of Patancheru, Andhra Pradesh, India

PHYSICO-CHEMICAL CHARACTERISTICS AND QUALITY ASSESSMENT OF SOME GROUND WATER SAMPLES FROM VAPI TOWN, GUJARAT, INDIA

Discipline Chemical Testing Issue Date Certificate Number T-3790 Valid Until Last Amended on - Page 1 of 5

Chemical Properties of Groundwater in Bhiloda Taluka Region, North Gujarat, India

Received: 04 th Jan-2014 Revised: 15 th Feb-2014 Accepted: 20 th Feb-2014 Research article

Analysis of Ground Water Quality Parameters around Kushmhi Railway Station Area

STUDIES ON WATER QUALITY INDEX OF GROUND WATER OF ALAND TALUKA, GULBARGA DISTRICT, KARNATAKA

Analysis of ground water quality of Jagdishpur industrial area of District C.S.M. Nagar (U.P.), India

Assessment of Physico chemical parameters of groundwater near dyeing industries at Tiruppur

QUALITATIVE ASSESSMENT OF GROUNDWATER IN SINGRAULI COALFIELD REGION, MADHYA PRADESH

Analysis of Metals in Water, Stream Sediments and Floodplain Soils Collected March 21-23, 2005 from the Bayou Creek System. David J.

Water Quality Concerns at Mines for Environmental Impact Assessment

Water QUALITY OF THANLWIN AND ATTARAN RIVERS

SPECIFICATION NO.1197S Addendum No.4 Attachment D. Appendix L- Ground Water Quality Data and Revised Construction Groundwater Discharge Plan

In the study of, using an innovative technique for removal of fluoride from drinking water, researcher, analyzed that for sorption studies, contact ti

Physico Chemical Analysis Of Drinking Water Of Pedavegi Mandal Westgodavari District, Andhrapradesh, India

Appendix U. Mapping of Water Quality Concentration Contours across the Province

CORRELATION STUDY AMONG WATER QUALITY PARAMETERS OF GROUNDWATER OF VALSAD DISTRICT OF SOUTH GUJARAT (INDIA)

Concentration of Metals (Cd, Hg, Ag; mean +SD) in sediment samples collected from Pit Specific Sediment Chemistry Monitoring for CMP 1 in May 2014.

SEASONAL VARIATIONS OF METALS AND OTHER MINERAL CONSTITUENTS OF RIVER YOBE

Appendix C1: Batch Kinetics Tests

Analysis on Water Quality of Haora River in Agartala with an Assessment of Water Quality Index

Point wise compliance for the conditions stipulated in Environmental Clearance of (Phase- I & II)

International Journal of Science, Environment and Technology, Vol. 5, No 2, 2016,

SABS Water Check. Inorganic Chemical proficiency testing provider for water laboratories. NLA 20 September 2011

Journal of Chemical and Pharmaceutical Research

ANNEXURE- II Proposed TOR

POLLUTION ANALYSIS OF WATER IN LIME INDUSTRY AREA

Transcription:

Available online at www.derpharmachemica.com Scholars Research Library Der Pharma Chemica, 2015, 7(3):221-225 (http://derpharmachemica.com/archive.html) ISSN 0975-413X CODEN (USA): PCHHAX Seasonal variations in physico-chemical characteristics of ground water collected from Kondapalli nearby VTPS-Vijayawada G. Krishnaveni*, K. Kirankumar and O. Sailaja Department of Chemistry, K B N College, Vijayawada, Andhra Pradesh, India ABSTRACT VTPS is one of the major sources for electricity to Andhra Pradesh state. It was located in Kondapalli village on Vijayawada-Hyderabad National Highway. Approximately 13 villages are there around of VTPS. In VTPS electricity is producing by rotating of turbines with steam of Krishna river water. Present study is carried out to determine the physicochemical characteristics of ground water of Kondapalli nearby VTPS-Vijayawada. There is no change in P H from location to location but there is difference between three seasons. Heavy metals are found in few places. Hardness, D.O, COD, Chloride, Fluoride and remaining parameters are analyzed and compared with IS 10500:2012 drinking water specifications. Keywords: VTPS, Vijayawada, Kondapalli, Physico- chemical properties, Heavy metals. INTRODUCTION DrNarla Tata Rao Thermal Power Plant is also known as Vijayawada Thermal Power Plant. It was developed under 4 stages, with the project cost of Rs 193 Crores and Rs 511 Crores respectively. The station stood first in country during 94-95, 95-96, 96-97, 97-98 and 2001-02 by achieving the highest plant load factor. VTPS is one of the major sources for electricity to Andhra Pradesh state. It is located in Kondapalli village on Vijayawada-Hyderabad National Highway. Approximately 13 villages are there around of VTPS. In VTPS electricity is being produced by rotating of turbines with steam of Krishna river water. In continuous process so many bi products are causing environmental (Air, water, Soil) pollution. In this study we have examined the Physico chemical parameters of drinking water and and impact of VTPS pollution on ground water of villages which are nearby VTPS. Open fly ash dump yards and coal burning are major causes of pollution near thermal power plants. Burning of coal and its smoke was identified as significant threat to the environment [1, 2]. Study Area In this study 3 season s (Monsoon-2013, Winter-2014, Summer-2014) 6 samples are collected from Kondapalli village. The sampling locations are given in Table.1. 221

MATERIALS AND METHODS Image.1 Location of VTPS nearby National Highway-9 and Krishna River Table.1 Sampling location GPS data 1 KP-1 80o 31 55.55E 16o 35 3.96N 2 KP-2 80o 31 55.29E 16o 35 17.76N 3 KP-3 80o 32 28.55E 16o 35 27.08N 4 KP-4 80o 32 24.25E 16o 35 49.62N 5 KP-5 80o 32 21.3E 16o 37 3.7N 6 KP-6 80o 32 8.89E 16o 35 37.56N Sample collection The samples are collected in clean glass bottles. After rinsing the bottles thoroughly with the sample water, the samples were collected. While collecting the samples, the glass bottles were filled completely without leaving some space for aeration as per the requirement [2-5]. The required chemicals are purchased with analytical grade from local vender in Vijayawada. The list of Equipments for this study shown in Table.2. Water samples are analyzed followed by standard methods. The type of methods are given in Table.3 Test Parameter(s) Table:2 List of Equipment S.NO Instrument Make and Model number 1 ph Meter Elico 2 Electrical Conductivity Meter Elico 3 U.V-Visible Spectrophotometer Tech comp, 2301,Hitachi software 4 Ion Selective Electrode Meter Elico 5 Atomic Absorption Spectrometer LABINDIA-7000 6 Electrical Balance Denver-A200DS 7 Flame photometer Electronics India- 1385 Table.3 Drinking water permissible and required parameters & List of methods Test Method Requirement acceptable Limit as per IS:10500: 2012 Permissible Limit in the absence of Alternative source as per IS 10500:2012 ph 4500. H + B 6.5 to 8.5 No relaxation Color 2120. B 5 15 2150. B Agreeable Agreeable Electrical Conductivity 2510-B Total Dissolved Solids at 180ºC 2540. C 500 2000 Turbidity 2130. B 1 5 Total Hardness as CaCO 3 2340. C 200 600 Calcium as Ca 3500. Ca.B 75 200 Magnesium as Mg 3500. Mg.B 30 100 222

Total Alkalinity as CaCO 3 2320. B 200 600 Chlorides as Cl - 4500. Cl -.B 250 1000 Sulphates as SO 4 4500. SO 2-4.E 200 400 Chemical Oxygen Demand 5220. B - - Biochemical Oxygen Demand IS: 3025 - - Dissolved Oxygen 4500. O.C Fluoride as F - 4500. F -.C 1 1.5 - Nitrates as NO 3 4500. NO - 3.B 45 No relaxation Sodium as Na 3500-Na.B Potassium as K 3500-K.B Cadmium as Cd APHA 3111B/3030E 0.003 No relaxation Mercury as Hg APHA 3111B/3030E 0.001 No relaxation Arsenic as As APHA 3111D/3030E 0.07 No relaxation Lead as pb APHA 3111B/3030E 0.01 No relaxation Total Chromium as Cr APHA 3111B/3030E 0.05 No relaxation Iron as Fe APHA 3111B/3030E 0.3 No relaxation Manganese as Mn APHA 3111B/3030E 0.1 0.3 Copper as Cu APHA 3111B/3030E 0.05 1.5 The physicochemical qualities of the ground water samples of kondapalli are investigated, and the level of metal ions estimated. The obtained results are compared with IS 10500:2012 drinking water standards. The IS 10500:2012 drinking water standards [6] are given in Table: 3. The concentration of the most significant pollutants in the various locations of Kondapalli in three seasons are shown in Table.4, Table.5, Table.6 respectively. Table: 4 Physico and chemical parameters of Kondapalli nearby VTPS-Vijayawada in Monsoon-2013 Test Parameter(s) Unit ph -- 7.3 7.4 7.6 7.6 7.5 7.2 Color Pt.Co <5 <4 <4 <5 <5 <5 Electrical Conductivity µmos/cm 1850 2400 2350 2220 2400 2010 Total Dissolved Solids at 180ºC mg/l 1450 1650 1200 1450 1550 1390 Turbidity NTU 1.45 3.02 3.05 3.85 2.40 2.85 Total Hardness as CaCO3 mg/l 510 440 430 425 380 360 Calcium as Ca mg/l 110 95 85 90 85 95 95Magnesium as Mg mg/l 60 50 40 55 35 45 Total Alkalinity as CaCO3 mg/l 350 330 350 360 375 410 Chlorides as Cl- mg/l 590 450 475 480 540 530 Sulphates as SO4 mg/l 340 310 280 375 370 360 Chemical Oxygen Demand mg/l <5 <6.3 <5 9.8 <5 <5 Dissolved Oxygen mg/l 4.1 4.2 4.0 4.1 4.0 4.0 Fluoride as F- mg/l BDL BDL 0.4 0.8 2.6 1.8 Nitrates as NO3- mg/l 66.8 74.1 55.6 50.2 55.3 59.6 Sodium as Na mg/l 75 85 90 95 80 85 Potassium as K mg/l 5 5 6 4 5 6 Lead as pb Mg/L 1.0 0.5 0.4 0.4 0.6 0.2 Total Chromium as Cr mg/l BDL BDL 0.05 BDL 0.08 0.06 Iron as Fe mg/l 0.44 0.40 0.35 0.45 0.40 0.42 Manganese as Mn mg/l BDL 0.05 0.04 BDL BDL BDL Copper as Cu mg/l BDL 0.04 0.02 0.10 BDL BDL 223

Table: 5 Physico and chemical parameters of Ibrahimpatnam nearby VTPS-Vijayawada in Winter-2014 Test Parameter(s) Unit ph -- 7.1 7.2 7.4 7.9 8.3 7.5 Color Pt.Co <5 <4 <4 <5 <5 <5 Electrical Conductivity µmos/cm 1927 2641 2582 2399 2593 2235 Total Dissolved Solids at 180ºC mg/l 1501 1732 1319 1464 1602 1460 Turbidity NTU 1.49 3.15 3.21 4.14 2.61 3.16 Total Hardness as CaCO3 mg/l 532 468 455 461 403 408 Calcium as Ca mg/l 123 106 129 104 99 107 Magnesium as Mg mg/l 68 55 49 63 40 52 Total Alkalinity as CaCO3 mg/l 379 352 377 381 394 431 Chlorides as Cl- mg/l 615 479 492 504 558 561 Sulphates as SO4 mg/l 362 337 306 389 393 397 Chemical Oxygen Demand mg/l <5 <6.3 <5 9.8 <5 <5 Dissolved Oxygen mg/l 4.0 4.1 4.2 4.3 4.2 4.1 Fluoride as F- mg/l 1.38 1.49 1.41 1.39 1.48 1.43 Nitrates as NO3- mg/l 46 44 47 47 50 52 Sodium as Na mg/l 81 92 107 112 86 91 Potassium as K mg/l 6 7 7 6 7 5 Lead as pb Mg/L BDL BDL BDL BDL BDL BDL Total Chromium as Cr mg/l BDL BDL 0.05 BDL BDL 0.05 Iron as Fe mg/l 0.48 0.44 0.39 0.51 0.45 0.48 Manganese as Mn mg/l BDL 0.11 BDL BDL 0.12 BDL Copper as Cu mg/l BDL 0.05 BDL 0.15 BDL BDL Table: 6 Physico and chemical parameters of Ibrahimpatnam nearby VTPS-Vijayawada in Summer-2014 Test Parameter(s) Unit ph -- 7.5 7.4 7.6 8.1 8.4 7.8 Color Pt.Co <6 <4 <5 <4 <5 <5 Electrical Conductivity µmos/cm 2156 2753 2690 2500 2793 2450 Total Dissolved Solids at 180ºC mg/l 1637 1864 1516 1571 1689 1501 Turbidity NTU 2.59 3.87 3.98 4.60 3.12 3.76 Total Hardness as CaCO3 mg/l 565 490 477 481 428 446 Calcium as Ca mg/l 141 123 149 128 102 174 Magnesium as Mg mg/l 81 67 59 80 68 75 Total Alkalinity as CaCO3 mg/l 411 398 403 425 436 467 Chlorides as Cl- mg/l 724 578 552 595 649 613 Sulphates as SO4 mg/l 371 358 338 395 387 398 Chemical Oxygen Demand mg/l <5 <5 <5 9.8 <5 <5 Dissolved Oxygen mg/l 4.9 5.2 4.9 5.3 4.8 5.4 Fluoride as F- mg/l 1.41 1.53 1.48 1.49 1.50 1.50 Nitrates as NO3- mg/l 68 52 62 55 59 60 Sodium as Na mg/l 98 101 118 129 97 107 Potassium as K mg/l 7.4 7.9 8.2 6.7 8.5 6.8 Lead as pb Mg/L BDL BDL BDL BDL BDL BDL Total Chromium as Cr mg/l 0.06 0.06 BDL 0.05 BDL BDL Iron as Fe mg/l 0.68 0.58 0.65 0.61 0.57 0.59 Manganese as Mn mg/l BDL BDL 0.14 0.19 0.22 BDL Copper as Cu mg/l BDL BDL 0.08 0.09 BDL 1.2 224

DISCUSSION There is a significant change in the ph value during the observation periods, the observed values are in the range 7.2(KP6) to 7.6(KP5) in Monsoon-2013, 7.1(KP1) to 8.3(KP5) in winter-2014, 7.4(KP2) to 8.4(KP5) in summer- 2014. In the period of summer has high ph: It may be due to high temperature in summer [7]. EC values are in the range of 1850(KP1) 2400(KP2, KP4) micromhos/cm in monsoon, 1927(KP1) 2641(KP2) micromhos/cm and in summer 2156(KP1) 2793(KP5) micromhos/cm. High EC values were observed for all the samples indicating the presence of high amount of dissolved inorganic substances in ionized formand also Higher electrical conductivity affected the germination of crops and it results in reduced yield [8]. The TDS is found up to 1650mg/l KP2 in monsoon season, 1732mg/l KP2 in winter-2014 and 1864mg/l KP2 in summer-2014. There is a considerable change in Hardness; the observed values are 360(KP6) 510(KP1) mg/ml in monsoon-2013, 403(KP5) - 532(KP1) mg/ml in winter-2014, 428(KP5) - 565(KP1) mg/ml in summer. There is little change in the samples in summer- 2014 because of temperature. There is no turbidity in all places in all seasons. Concentration of nutrients like nitrate, phosphate, is within the permissible limits. The fluoride content of groundwater generally ranges from 0.2 to 1.5 mg L -1 [9, 10]. Fluoride is observed in all places in different seasons. KP-5 and KP-2 showed higher value for Fluoride i.e. 2.6, 1.49 and 1.53 mg/l in monsoon, winter and summer seasons respectively. The present study areas are located at Krishna River in 0.5-1.0 km. The COD, BOD, DO levels are within the limits. Most of the samples contained Pb, Cr remaining metals like Hg, As are absent in all seasons. CONCLUSION There is no much deviation from IS: 10500: 2012 drinking water standards except Fluoride, Pb, Cr. But these three parameters have impact on human health in long period. Indirectly the VTPS effluents are entering in to ground water in the form of toxic metals. The public have been using mineral water for drinking purpose for the past 4 to 5 years. But very poor people are in a critical position in few slum areas. The government and village development authorities, Public health centers should aware of the problem of pollution in the ground water consumed by poor people. Acknowledgement One of the authors (Dr. G.Krishnaveni) is thankful to UGC for the financial assistance in the minor research project with title Identification of VTPS (Vijayawada Thermal Power Station) pollution effect on surrounding villages Ref. No. MRP -4343/12 (MRP/UGC-SERO) Dtd: 26.03.2012. REFERENCES [1] B. ThoratPrerana and N. Charde Vijay, Int. Rese. Jour. Envi. Scie, 2013, 2(9), 10-15. [2] S. Shama, R.Iffat, IA. Mohammad, I. A. and A. Safia, Pakistan. Research J. of Chemical Sciences,2011,1: 24-30. [3] APHA-AWWA WPCR 1998 Standard methods for examination of water waste water 19th Edition APHA, Washington, U.S.A. [4] EO. Longe, MR. Balogun, Research Journal of Applied Sciences, Engineering and Technology, 2010, 2(1), 39. [5] DS. Ramteke, CA. Moghe, Mannual on water & waste water analysis, National Environmental Engineering Research institute Nagpur India, (1998). [6] Chaitanya et al., Carib. Journal of Science and Technology,2014, 2: 451-456, [7] Larsen, D. (Ed.). (2013). Temperature Dependent of the ph of pure Water. In UC Davis Chem Wiki. Retrieved from http://chemwiki.ucdavis.edu/physical_chemistry/acids_and_bases/aqueous_solutions/the_ph_scale/temperature _Dependent_of_the_pH_of_pure_Water [8] CH. Srinivas, P. Ravi Shankar, R. Venkatesan, MS.Sathya Narayan Rao, and R. Ravinder Reddy, Studies on ground water quality of Hyderabad. Poll. Res, 2000, 19: 285 289. [9] EPA (1980a),Reviews of the environmental effects of pollutants: IX. Fluoride. Cincinnati, OH.Health Effects Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency. EPA-600/1-78- 050. [10] M. Fleischer, Fluoridecontent of ground water in the conterminous United States. U.S. Geological Survey Miscellaneous Geological Investigation I-387. Washington, DC., U.S. Geological Survey, (1962). 225