Table R (1) Allowable Spans and Loads for Wood Structural Panels for Roof and Subfloor. Sheathing and Combination Subfloor Underlayment

Similar documents
City of Republic Community Development Girder and Header Spans for Exterior Walls

AdvanTech Sheathing and Subfloor Panels

2012 IRC Table R802.4(2) - Ceiling Joist Spans for Common Lumber Species (Uninhabitable Attics With Limited Storage, Live Load = 10 psf, L/Δ = 240)

Explaining PS 1 and PS 2 Gradestamps

CHAPTER 5 FLOORS SECTION R501

Warmboard-S Radiant-Floor Heating Panels PR-V180 Warmboard, Inc. Revised February 19, 2018

CHAPTER 5 FLOORS SECTION R501

CHAPTER 5 FLOORS SECTION R501

PRP-108 Performance Standards and Policies for Structural-Use Panels

From: Community Development I Building Inspections. Re: IRC 2012 Roofing Requirements. To: Whom it may concern

FIGURE R502.2 FLOOR CONSTRUCTION

LP OSB Sheathing & Structural 1 Sheathing

Garage/Accessory Structures

PR-L274 Nordic Structures Revised April 16, 2017

PLYWOOD FLOATING FLOOR

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

Specifications. Materials and Fabrication. Physical Properties. Environmental Impact. Sizes. Installation - General Requirements.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: STARK TRUSS COMPANY, INC.

KERTO HEADER INSULATED LVL HEADER 31/2", 51/2" 3 1/2" AND 5 1/2" THICKNESSES DESIGN VALUES USA

ZIP System Sheathing Load-Span Tables

1. The subfloor must be structurally sound and able to withstand live and dead loads with a deflection limitation of L/360.

PFC-5804* Reissued February 1, Filing Category: DESIGN Wood

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California *Revised April 2003

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

Building Division Informational Handout

SECTION R614 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council

Trusted ICC ES APA TH STREET. Conformity! subject of the

Timber Products Inspection, Inc.

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood, Plastics, and Composites (06) SECTION: Structural Panels ( )

Section II Subfloor Guidelines & Specifications Page Chapter 4 Wood Subfloor Guidelines 23 Chapter 5 Concrete Subfloor Guidelines 26 Chapter 6

International Beams Revised June 15, 2018

Plywood, Composite Wood Products, High-Pressure Laminates

ALTERNATE DESIGN METHODOLOGY FOR UNREINFORCED MASONRY BUILDINGS

CHAPTER 5 FLOORS SECTION R501

BUILDING PERMIT REQUIREMENTS FOR: RESIDENTIAL DECKS CITY OF ESCONDIDO BUILDING DIVISION 201 N. BROADWAY, ESCONDIDO, CA (760)

******************************************************************************

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

The Engineered Wood Association DESIGN/CONSTRUCTION GUIDE NONRESIDENTIAL ROOF SYSTEMS

BACKGROUND While many factors can contribute to an installation failure, we believe. by Frank Woeste, P. E. and Peter A. Nielsen

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

Residential Patio Cover Specifications

GLOBAL LVL HEADERS, BEAMS AND COLUMNS. 1.9E-2850Fb. 1.9E-2850Fb. User guide User guide. lvlglobal.com

Listing Report: MUR Reissue Date: 12/07/17 This report is subject to annual review

OSB. Design and Application Guide

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

Stark Truss Company, Inc. Revised December 14, 2018

Part 1: Vocabulary Select the best answer and write the corresponding letter in the space provided.

Boise Cascade Company Revised June 25, 2018

HIGH PERFORMANCE FIRE RETARDANT TREATED WOOD PRODUCTS

Appendix D. -Weyerhaeuser Fire Rated Assembly Listings-

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

AraucoPly panels offer. Versatility Strength with Lighter Weight High Quality Panel Construction. Light Uniform Color and Easy Workability

RESIDENTIAL RE-ROOFING PERMIT APPLICATION

MFMA Guide Specification for Sleeper and Sleeper with Plywood Floor Systems

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: PACIFIC WOODTECH CORPORATION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: LOUISIANA PACIFIC CORPORATION

ANSI/APA PRS Standard for Performance-Rated Structural Insulated Panels in Wall Applications

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

Joint Evaluation Report ICC-ES (800) (562)

APPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE

PinkWood Ltd. Revised September 29, 2017

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

Typical Single-Story Framing Section

WIND & SEISMIC 2008 EDITION ASD/LRFD WITH COMMENTARY. American Forest & Paper Association. American Wood Council ANSI/AF&PA SDPWS-2008

Attachment A. USG Minimum Design and Construction Requirements for Wood Framed Structures

TT-006B JULY 2008 TABLE A. ASTM C 627-TESTED ASSEMBLIES NOT LISTED BY TCNA. Tile Adhesive

Diaphragms 2. Design Process. Design Process. Diaphragms are the roofs and floors of the upper stories

U.S. EDITION RESIDENTIAL CONSTRUCTION DETAILS SAMPLE. A visual guide to construction detailing. Emma Walshaw

The LP Family of Sub-Flooring

Typical Deck Details Based on the 2009 International Residential Code (Designed and Printed August 2010)

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

WIND & SEISMIC 2008 EDITION ASD/LRFD WITH COMMENTARY. American Forest & Paper Association. American Wood Council ANSI/AF&PA SDPWS-2008

Originally Issued: 03/31/2017 Valid Through: 04/30/2018

DIVISION: CONCRETE SECTION: CEMENTITIOUS WOOD FIBER DECKS DIVISION: FINISHES SECTION: ACOUSTIC ROOM COMPONENTS

Guidelines for planning the construction of a porch.

Murphy LVL Limit States Design Guide 2.0 E-LVL 2.2 E-LVL

RESIDENTIAL ATTACHED CARPORTS BUILDING PERMIT REQUIREMENTS

Chapter 23: Wood 2015 INTERNATIONAL BUILDING CODE COMMENTARY 23-1

RESIDENTIAL PATIO COVER Submittal/Permitting Guidelines

The purpose of this memo is to respond to the comments received in response to the May 1, 2007, staff letter and the revised criteria.

LPI 56 Technical Guide

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC.

City of Bemidji Building Office City Hall 317 4th Street NW Bemidji, Minnesota Phone Fax emi mn s

Pacific Woodtech Corporation Revised January 26, 2018

SDPWS. Special Design Provisions for Wind & Seismic 2015 EDITION

Overcoming Structural Floor Squeaks in Wood Framed Construction Presented by: Don Simon Huber Engineered Woods

ADVANTECH SHEATHING SUBMITTAL FORM

Murphy Laminated Veneer Lumber Murphy Engineered Wood Division Revised May 30, 2013

MASTER GUIDE SPECIFICATION

WOOD CHAPTER 23. PARTICLEBOARD. A generic term for a panel primarily composed of cellulosic materials (usually wood), generally in

ESR-1405 Reissued November 1, 2013 This report is subject to renewal December 1, 2015.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

Page 2 of 5 1. Flooring Systems The flooring system shall consist of one of the following: System No. 1 Subflooring Nom 23/32 in. thick wood structura

CHAPTER 23 WOOD SECTION 2301 CRIPPLE WALL. GENERAL

DEVELOPMENT SERVICES BUILDING INSPECTIONS

Transcription:

City of Republic - Community Development Department Roof and Subfloor Sheathing Spans Revision Date: January 2017 Table R503.2.1.1(1) Allowable Spans and Loads for Wood Structural Panels for Roof and Subfloor a, b, c Sheathing and Combination Subfloor Underlayment Span Minimum Nominal Panel Thickness (inch) Allowable Live Load (psf) h,i Maximum Span (inches) Load (pounds per square foot, at maximum span) Maximum Span (inches) Rating With Without Total Edge Edge Live Load Span @ Span @ Support d Load Support 16 o.c. 24 o.c. Sheathing e Roof f Subfloor j 16/0 3 / 8 30 --- 16 16 40 30 0 20/0 3 / 8 50 --- 20 20 40 30 0 24/0 3 / 8 100 30 24 20 g 40 30 0 24/16 7 / 16 100 40 24 24 50 40 16 32/16 15 / 32, 1 / 2 180 70 32 28 40 30 16 h 40/20 19 / 32, 5 / 8 305 130 40 32 40 30 20 h,i 48/24 23 / 32, --- 175 48 36 45 35 24 60/32 7 / 8 --- 305 60 48 45 35 32 Underlayment, C-C plugged, Single Floor e Span @ 16 o.c. Span @ 24 o.c. Roof f Combination subfloor underlayment k 16 o.c. 19 / 32, 5 / 8 100 40 24 24 50 40 16 i 20 o.c. 19 / 32, 5 / 8 150 60 32 32 40 30 20 i, j 24 o.c. 23 / 32, 240 100 48 36 35 25 24 32 o.c. 7 / 8 --- 185 48 48 50 40 32 48 o.c. 1 3 / 32, 1 1 / 8 --- 290 60 60 50 40 48 a. The allowable total loads were determined using a dead load of 10 psf. If the dead load exceeds 10 psf, then the live load shall be reduced accordingly. b. Panels continuous over two or more spans with long dimension (strength axis) perpendicular to supports. Spans shall be limited to values shown because of possible effect of concentrated loads. c. Applies to panels 24 inches or wider. d. Lumber blocking, panel edge clips (one midway between each support, except two equally spaced between supports when span is 48 inches), tongue-and groove panel edges, or other approved type of edge support. e. Includes Structural 1 panels in these grades. f. Uniform load deflection limitation: 1/180 of span under live load plus dead load, 1/240 of span under live load only. g. Maximum span 24 inches for 15/32-and 1/2-inch panels. h. Maximum span 24 inches where 3/4-inch wood finish flooring is installed at right angles to joists. i. Maximum span 24 inches where 1.5 inches of lightweight concrete or approved cellular concrete is placed over the subfloor. j. Unsupported edges shall have tongue-and-groove joints or shall be supported with blocking unless minimum nominal 1/4-inch thick underlayment with end and edge joints offset at least 2 inches or 1.5 inches of lightweight concrete or approved cellular concrete is placed over the subfloor, or 3/4-inch wood finish flooring is installed at right angles to the supports. Allowable uniform live load at maximum span, based on deflection of 1/360 of span, is 100 psf. k. Unsupported edges shall have tongue-and-groove joints or shall be supported by blocking unless nominal 1/4-inch-thick underlayment with end and edge joints offset at least 2 inches or 3/4-inch wood finish flooring is installed at right angles to the supports. Allowable uniform live load at maximum span, based on deflection of 1/360 of span, is 100 psf, except panels with a span rating of 48 on center are limited to 65 psf total uniform load at maximum span. l. Allowable live load values at spans of 16" o.c. and 24" o.c taken from reference standard APA E30, APA Engineered Wood Construction Guide. Refer to reference standard for allowable spans not listed in the table.

Roof and Subfloor Sheathing Spans Page 2 Commentary: The maximum spans for wood structural panel floor and roof sheathing are limited by the stresses and deflection imposed by the design live loads. For convenience, the trademarks of the inspection agencies include a span rating, which appears as two numbers separated by a slash (32/16 or 48/24 for example). The first number represents the maximum recommended span for roof sheathing when the panels are applied with the long dimension (strength axis) across three or more supports and the edges are blocked or when other support required by the table is provided. The second number indicates the maximum recommended span when the panel is used for structural floor sheathing with the panels applied with the long dimension (strength axis) across three or more supports. Single panels intended for single floor application will be marked with a single number representing this span. The edges of the wood structural panels between floor supports are prevented from moving relative to each other by tongue and groove panel edges, by the addition of wood blocking or by the use of an approved underlayment or structural finished floor system. Identification and grade (R503.2.1): Wood structural panel sheathing used for structural purposes shall conform to DOC PS 1, DOC PS 2 or, when manufactured in Canada, CSA O437 or CSA O325. All panels shall be identified for grade, bond classification, and Performance Category by a grade mark or certificate of inspection issued by an approved agency. The Performance Category value shall be used as the nominal panel thickness or panel thickness whenever referenced in this code. Commentary: Plywood that performs a load-carrying function in floor construction must conform to a known quality control standard; therefore, a method of identifying the limitations under which the plywood may be used is needed. This is accomplished by a grade mark or certificate of inspection issued by an approved agency. Table R503.2.1.1(2) Allowable Spans for Sanded Plywood Combination Subfloor Underlayment a Identification Species Group b 1 2, 3 4 Spacing of Joists (inches) 16 20 24 1 / 2 5 / 8 5 / 8 7 / 8 7 / 8 1 a. Plywood continuous over two or more spans and face grain perpendicular to supports. Unsupported edges shall be tongue-and-groove or blocked except where nominal 1/4-inch-thick underlayment or 3/4-inch wood finish floor is used. Allowable uniform live load at maximum span based on deflection of 1/360 of span is 100 psf. b. Applicable to all grades of sanded exterior-type plywood. Commentary: For exterior type sanded plywood grades, the thickness required for a specific span is related to the specific grouping of the panel used. For example, species Group 1 may be 1 / 2 inch for 16 inch joist spacing, but Group 4 will require a thickness of inch for the same span. When the panels are used as a combination subfloor/ underlayment, extra precautions should be observed in attaching the panels to the floor framing. Joints in adjacent panels should not be continuous and should not occur at locations where the orientation of the joist supports is different. Subfloor and combined subfloor underlayment (R503.2.1.1): Where used as subflooring or combination subfloor underlayment, wood structural panels shall be of one of the grades specified in Table R503.2.1.1(1). When sanded plywood is used as combination subfloor underlayment, the grade, bond classification, and Performance Category shall be as specified in Table R503.2.1.1(2).

Page 3 Revision Date: January 2017 Commentary: This section specifies grades of wood structural panels when they are used as subflooring or combination subflooring underlayment. It also addresses the use of sanded plywood as a combination subfloor underlayment. A floor system could consist of three elements: (1) a subfloor, (2) an underlayment or a combination subfloor/ underlayment system and (3) a finished floor surface material. A finished surfacing material may be wood strip flooring, tongue-and-groove flooring or various types of resilient floor coverings such as vinyl, tile or carpeting. Wood structural panels are manufactured for use as either structural subfloor or combination subfloor underlayment. The allowable spans for structural subflooring and combination subfloor underlayment are based on the wood structural panels face grain strength axis parallel to its supporting member, or they are based on the panels being continuous over two or more spans, with a face grain placed perpendicular to the supports. These qualifications are critical in determining the permissible spans. Most wood structural panels are considerably stronger when their face grain is parallel to the supports and continuous over two or more spans. Panels with multiple spans have greater capacity than those that are simply supported between the two joists. Allowable spans (R503.2.2): The maximum allowable span for wood structural panels used as subfloor or combination subfloor underlayment shall be as set forth in Table R503.2.1.1(1), or APA E30. The maximum span for sanded plywood combination subfloor underlayment shall be as set forth in Table R503.2.1.1(2). Commentary: Table R503.2.1.1(1) indicates spans for plywood and wood structural panels used as subflooring. This table also covers roof sheathing and is referenced in Section R803.2.2 for that purpose. The span limitations are predicated on the grade of plywood used. In the case of rated sheathing used as structural subflooring, the maximum span is easily identified through the panel span rating (identification index). Where the panel span rating is stamped on the sheet of plywood, the denominator represents the allowable span of the plywood floor sheathing {+see figure R503.2.2(1)}. An illustration of the limitations imposed by notes j and k to Table R503.2.1.1(1) on combination subfloor underlayment applications is illustrated in Figure R503.2.2(2). Allowable increases in the maximum span for certain span ratings are permitted as described in Notes h and I to Table R503.2.1.1(1). In lieu of using Table R503.2.1.1(1), the code permits the use of APA E30 Engineered Wood Construction Guide. When plywood combination subfloor underlayment is to be used, the allowable span as listed in Table R503.2.1.1(2) is applicable to underlayment grade C- C plugged and sanded exterior type plywood of specific species. Figure R503.2.1 Plywood Grade Mark Examples

Roof and Subfloor Sheathing Spans Page 4 Figure R503.2.2(1) - Identification of Plywood Subfloor Span Limitations Figure R503.2.2(2) - Combination Subfloor Underlayment Alternatives

City of Republic - Community Development Department Primary Business Address 204 North Main Street Republic, MO 65738-1473 Across from City Hall Phone: 417-732-3150 Fax: 417-732-3199 E-mail: wzajac@republicmo.com The Community Development Department is made up of five full-time employees including a Department Director, Administrative Assistant, Principal Planner, Building Inspector, and Code Compliance Official. Our office is located at 204 North Main Street. The goal of the department is to serve the citizens of Republic through pursuance, guidance, and assistance in the development of the City. This is accomplished through marketing and strategic planning accompanied by oversight and enforcement of the City's Building Codes, Zoning Codes and Subdivision Regulations. We re on the Web! http:// www.republicmo.com/286/ Community-Development Community Development Department