KS SERIES - VERTICAL INSTALLATION

Similar documents
200 / 300 SERIES PANELS COLD STORAGE

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET

900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900

KARRIER PANEL - BRICK

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing

COMMERCIAL & INDUSTRIAL CI-CFR-INDEX SHEET INDEX CI-CFR-INDEX SHEET INDEX CI-CFR-INFO C & I DISCLAIMER

TYPICAL ROOF CONDITION LAYOUT

ELEVATION FOR DETAIL REFERENCE ONLY

SUSPENSION REQUIREMENTS SEE DETAIL B1.2 TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 2" MODULE. SPECIFICATIONS (unless noted otherwise)

4 " " SEE DETAIL B1.2. SPECIFICATIONS (unless noted otherwise)

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

FACE CFP - HORIZONTAL PANELS - OPTION 'B'

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS

ELEVATION FOR DETAIL REFERENCE ONLY

Architectural Roof and Wall Products Guide Specifications

6" MAX CARRIER OVERHANG, TYP. MAX CARRIER SPACING VARIES DEPENDING ON DESIGN WIND PRESSURE, SEE DETAIL B1.2, TYP.

SPECIFICATIONS (unless noted otherwise)

Architectural Wall Products Guide Specifications

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution

Metafor Panel System Installation Guide

Duct Wrap Flexible Wraps

SECTION NON-STRUCTURAL METAL FRAMING

Architectural Roof and Wall Products Guide Specifications

Flushglaze For Steel Tube Applications and Horizontal Panels. Façades Installation Guide

ELEVATION FOR DETAIL REFERENCE ONLY

COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE

ELEVATION FOR DETAIL REFERENCE ONLY

Designwall 2000/4000. Façades Installation Guide

The better way to build TM. Installation Manual NAILBASE PANELS

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

Architectural Roof Products Guide Specifications

TABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers

Architectural Roof Products Guide Specifications

Fundamentals of Insulated Panel Installation. MBCEA 2016 Clearwater, FL

HOME SYSTEMS CONSTRUCTION PROCEDURE

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION ACOUSTICAL PANEL CEILINGS

Filled Cavity (FC) / Long Tab Banded Installation Instructions

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

WeatherSmart Air Barrier Installation Guide

Light-Metal Roof Edge, Raised

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

Thin Brick Façade. Façades Installation Guide

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

ELEVATION FOR DETAIL REFERENCE ONLY

Commercial Flashing Details

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.

AXIOM Building Perimeter System Assembly and Installation Instructions

Architectural Roof and Wall Products Guide Specifications

SECTION PRE-ENGINEERED METAL BUILDING

SECTION PRE-ENGINEERED BUILDING INSULATION

Installation Guidelines for all Quaker products with nail fins New construction nail fin installation with a drainable weather resistant barrier.

RS32 Multi-Section Skylight System under/over seam clip double diverter

CONTOUR CORRUGATED PANEL

Installation Instructions

SECTION METAL BUILDING SYSTEMS

Prestige Series 12. Installation guide

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 11

SECTION GYPSUM BOARD PART 1 - GENERAL

MID-RISE DESIGN & CONSTRUCTION

SECTION GYPSUM BOARD ASSEMBLIES

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

WEC Manufacturing Phone: (901) Website: Itswec.com

INSULATED PANEL OVERVIEW

SECTION HANGERS AND SUPPORTS FOR PLUMBING

DETAIL INSTRUCTION No. 1

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

LLOYD INDUSTRIES INC. DAMPER INSTALLATION INSTRUCTIONS

Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19

SECTION GYPSUM BOARD

1.52mm 1.52mm. Exterior Siding Sheet: Fabricated from Z275 steel material conforming to ASTM A653M grade 230 steel

Student Services & Classroom Addition

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

INSTALLATION MANUAL KOCH

Container Installation Guide

RS24-10 Single-Section Skylight System

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

CEILING & WALL SYSTEMS

Technical Data Sheet

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 17

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

GARAGE MAIN FLOOR PLAN

Ultra Wall System. CAD Detail Sets

BENCHMARK Evolution Axis

Hip Detail. Construction Details. KS1000 LP/CR Roof. Hip Detail STANDARD ENHANCED ENHANCED STANDARD. Mineral fibre insulation

The Olympia Difference

Chapter 32 - Garage. June 2015 Garages 32-1

Proper Installation of Insulated Metal Wall Panels

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.

A. Metal Building System Description: Rigid modular, with interior columns with expandable endwall.

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

ELEVATION FOR DETAIL REFERENCE ONLY

Transcription:

CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV KS 45 EXPANDED PANEL JOINT CS-PJ-04-KSV KS 45 ENGAGED PANEL JOINT CS-PJ-05-KSV INTERMEDIATE SUPPORT CS-PJ-06-KSV LINER PANEL TO CONCRETE WITH SUPPORT CS-PJ-07-KSV LINER PANEL TO CONCRETE CS-BS-01-KSV BASE DETAIL - INSULATED SLAB HEAVY GAUGE ANGLE CS-BS-02-KSV BASE DETAIL - INSULATED SLAB LIGHT GAUGE Z CS-BS-03-KSV BASE DETAIL - PARTITION W/ FLOOR INSULATION CS-BS-04-KSV BASE DETAIL - INSULATED/NON-INSULATED CS-BS-05-KSV BASE DETAIL - PART. W/ CURBS INSULATED CS-BS-06-KSV BASE DETAIL - PART. NON-INSULATED CS-BS-07-KSV BASE DETAIL - LINER PANEL CS-BS-08-KSV BASE DETAIL - PART. W/ CURBS NON-INSULATED CS-BS-09-KSV BASE DETAIL - PART. W/ CURBS (ALTERNATE) CS-BS-10-KSV PARTITION BASE ON TOP OF CURB CS-OC-01-KSV OUTSIDE CORNER - FLUSH TRIM CS-OC-02-KSV OUTSIDE CORNER AT PARTITION CS-OC-03-KSV OUTSIDE CORNER LINER PANEL AT CONC WALL INDEX SHEET

CS-IC-01-KSV CS-IC-02-KSV CS-FO-01-KSV CS-FO-02-KSV CS-ST-01-KSV CS-RK-01-KSV CS-RK-02-KSV CS-EV-01-KSV CS-CE-01-KSV CS-CE-02-KSV CS-CE-03-KSV CS-CE-04-KSV CS-CE-05-KSV CS-CE-06-KSV CS-CE-07-KSV CS-CE-08-KSV CS-CE-09-KSV CS-CE-10-KSV CS-TL-01-KSV CS-TL-02-KSV CS-TL-03-KSV CS-TL-04-KSV INSIDE CORNER - FLUSH TRIM PARTITION TO EXTERIOR WALL HEADER CONDITION JAMB CONDITION STACK JOINT RAKE RAKE W/ MEMBRANE ROOF LOW EAVE INTERIOR WALL TO CEILING INTERIOR WALL TO CEILING - 'T' SECTION CEILING CHANNEL CEILING TEE CEILING TEE ASSEMBLY CEILING CHANNEL ASSEMBLY CEILING TO WALL - LONGITUDINAL CEILING TO WALL - TRANSVERSE PARTITION TO ROOF PARTITION TO ROOF WITH BLOCKING TRIM END LAP TRIM LAP WITH HEM TRIM END LAP WITH LAP STRIP TRIM LAP AT FRAMED OPENING INDEX SHEET

DISCLAIMERS: THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. REFRIGERATION EQUIPMENT IN COMBINATION WITH THE TEMPERATURE DIFFERENTIAL BETWEEN BUILDING EXTERIOR AND INTERIOR CAN CREATE NEGATIVE AIR PRESSURE WITHIN THE BUILDING (WARM AIR FROM OUTSIDE THE BUILDING IS DRAWN INTO THE BUILDING THROUGH AIR LEAKS IN THE BUILDING ENVELOPE). AS A RESULT, VAPOR SEALS ARE OF PRIMARY CONCERN TO PROPER COLD STORAGE PERFORMANCE. IN GENERAL, COLD STORAGE FACILITIES REQUIRE THE PRIMARY VAPOR BARRIER TO BE ON THE EXTERIOR (I.E. ), RATHER THAN INTERIOR SIDE OF THE PANEL. PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS. ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION AND ILLUSTRATION PURPOSES ONLY. CONTACT KINGSPAN TECHNICAL SERVICES FOR MAXIMUM ALLOWABLE PANEL SPANS AND FASTENING PATTERNS. ALL SEALANTS TO BE COMPATIBLE WITH VAPOR BARRIERS AS SHOWN COLD STORAGE DISCLAIMER

CORE DEPTHS: 2", 2.5", 3", 4", 5", 6" STEEL GAUGES: EXTERIOR: (REFER TO PROFILE) INTERIOR: 26, 24, 22 MODULE WIDTH: 24", 30", 36", 42" PANEL ORIENTATION: VERTICAL EMBOSSING: EXTERIOR: STUCCO / SMOOTH* INTERIOR: STUCCO / SMOOTH LENGTHS: MINIMUM: 8'-0" MAXIMUM: 53'-0" FEMALE JOINT INTERIOR FACE KS MINI WAVE (MW) SHADOWLINE MALE JOINT 2" - 6" EXTERIOR FACE MINI-WAVE (24GA, 22GA ONLY) 42" COVERAGE (36", 30", & 24" OPTIONAL) SHADOWLINE INTERIOR FACE FEMALE JOINT KS SL FLAT EXTERIOR FACE FLAT (26GA, 24GA, 22GA) 42" COVERAGE (36", 30", & 24" OPTIONAL) MALE JOINT 2" - 6" SHADOWLINE INTERIOR FACE FEMALE JOINT KS GRANITSTONE/QUARTZ (GS) EXTERIOR FACE GRANITSTONE / QUARTZ (24GA, 22GA ONLY) 42" COVERAGE (36", 30", & 24" OPTIONAL) MALE JOINT 2" - 6" INTERIOR FACE SHADOWLINE or FLAT EXTERIOR FACE (22GA ONLY) KS OPTIMO (OPE or OPS) 40" COVERAGE (24", 30", 36" OPTIONAL) OPTIONAL TRIMLESS ENDS FLAT 2" - 4" NOTE: MAX LENGTH: EMBOSSED: 32'-0" SMOOTH: 20'-0" KS SERIES PANEL PROFILES

CORE DEPTHS: 2", 2.5", 3", 4", 5", 6" STEEL GAUGES: EXTERIOR: (REFER TO PROFILE) INTERIOR: 26, 24, 22 MODULE WIDTH: 24", 30", 36", 42" PANEL ORIENTATION: VERTICAL EMBOSSING: EXTERIOR: STUCCO / SMOOTH* INTERIOR: STUCCO / SMOOTH LENGTHS: MINIMUM: 8'-0" MAXIMUM: 53'-0" FEMALE JOINT INTERIOR FACE KS MINI WAVE (MW) SHADOWLINE MALE JOINT 2" - 6" EXTERIOR FACE MINI-WAVE (24GA, 22GA ONLY) 42" COVERAGE (36", 30", & 24" OPTIONAL) SHADOWLINE INTERIOR FACE FEMALE JOINT KS SL FLAT EXTERIOR FACE FLAT (26GA, 24GA, 22GA) 42" COVERAGE (36", 30", & 24" OPTIONAL) MALE JOINT 2" - 6" INTERIOR FACE SHADOWLINE FEMALE JOINT KS GRANITSTONE/QUARTZ (GS) EXTERIOR FACE (24GA, 22GA ONLY) GRANITSTONE / QUARTZ 42" COVERAGE (36", 30", & 24" OPTIONAL) MALE JOINT 2" - 6" INTERIOR FACE SHADOWLINE or FLAT EXTERIOR FACE (22GA ONLY) KS OPTIMO (OPE or OPS) 40" COVERAGE (24", 30", 36" OPTIONAL) OPTIONAL TRIMLESS ENDS FLAT 2" - 4" NOTE: MAX LENGTH: EMBOSSED: 32'-0" SMOOTH: 20'-0" KS SERIES PANEL PROFILES

CORE DEPTHS: 2", 2.75", 3", 4", 5", 6", 8" STEEL GAUGES: EXTERIOR:26, 24, 22 INTERIOR: 26, 24, 22 MODULE WIDTH: 45.375" (45 3 8") PANEL ORIENTATION: VERTICAL EMBOSSING: EXTERIOR: STUCCO / SMOOTH INTERIOR: STUCCO / SMOOTH LENGTHS: MINIMUM: 8'-0" MAXIMUM: 53'-0" INTERIOR FACE SHADOWLINE MALE JOINT FEMALE JOINT EXTERIOR FACE KS SHADOWLINE INTERIOR (KSSLI) SHADOWLINE 2"-8" 45.375" (45 3 8") KS SERIES PANEL PROFILES

HORIZONTAL SUPPORT MALE LEG FEMALE POCKET 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT (2) 1 4" - 14 HEX HEAD FASTENERS WITHOUT WASHER OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT (AT "WARM" SIDE JOINT) WALL PANEL INSTALLATION DIRECTION NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL * VERIFY FIRST PANEL ENGAGEMENT AND ADJUST ACCORDINGLY KS SERIES EXPANDED JOINT

HORIZONTAL SUPPORT MALE JOINT FEMALE JOINT PANEL MODULE 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT (2) 1 4" - 14 HEX HEAD FASTENERS WITHOUT WASHER 1 8 " OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT (AT JOINT) WALL PANEL INSTALLATION DIRECTION KS SERIES ENGAGED JOINT

OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) MALE LEG FEMALE POCKET CONTINUOUS BUTYL SEALANT (AT "WARM" SIDE JOINT) WALL PANEL INSTALLATION DIRECTION NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL * VERIFY FIRST PANEL ENGAGEMENT AND ADJUST ACCORDINGLY KS 45 SERIES EXPANDED JOINT

(SPACING AS REQUIRED PER PANEL ANALYSIS) OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT (AT JOINT) (SPACING AS REQUIRED PER PANEL ANALYSIS) WALL PANEL INSTALLATION DIRECTION KS 45 SERIES ENGAGED JOINT

OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) MALE LEG FEMALE POCKET CONTINUOUS BUTYL SEALANT (AT "WARM" SIDE JOINT) WALL PANEL INSTALLATION DIRECTION NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL * VERIFY FIRST PANEL ENGAGEMENT AND ADJUST ACCORDINGLY INTERMEDIATE SUPPORT

(SPACING AS REQUIRED PER PANEL ANALYSIS) OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT (AT JOINT) (SPACING AS REQUIRED PER PANEL ANALYSIS) WALL PANEL INSTALLATION DIRECTION LINER PANEL TO CONCRETE WITH SUPPORT

OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) INTERIOR OF BUILDING EXTERIOR OF BUILDING CONTINUOUS BUTYL SEALANT AT PANEL JOINT STRUCTURAL FRAMING (2) 1 4" - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT 2 1 4 " 1" 3 4 " 2 1 4 " 3 4 " 5 16 " Ø 5 16 " Ø STANDARD: 12 GA. STAINLESS STEEL TWO-HOLE HIDDEN FASTENER CLIP OPTIONAL: 12 GA. STAINLESS STEEL ONE-HOLE HIDDEN FASTENER CLIP NOTE: CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS LINER PANEL TO CONCRETE

"Z" TRIM 2 BEADS OF BUTYL SEALANT ON EACH SIDE "Z" TRIM LAP TRIM MIN. 3" TRIM LAP SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) SLIP SHEET TO PROTECT PANELS HEAVY GA. BASE ANGLE CONTINUOUS HEAVY BEAD OF BUTYL SEALANT FASTENER TO CONCRETE (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT BASE TRIM W/ POP RIVETS @ 8" O.C. SET PANEL IN CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT CONTINUOUS "Z" TRIM SET IN BUTYL SEALANT (SEE LAP TRIM ABOVE FOR "Z" TRIM) CONCRETE CURB * ENSURE THERMAL BREAK CUT IS DEEP ENOUGH TO CUT METAL AT PANEL JOINT CONCRETE SLAB FIELD CUT THERMAL BREAK FLOOR INSULATION F.I.P INSULATION SUB SLAB REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF BASE CONDITION CONTINUOUS BUTYL SEALANT W/ MARRIAGE BEAD TO VERTICAL PANEL JOINT VAPOR BARRIER NOTES: 1) BASE ANGLE MUST BE FASTENED SECURELY TO SLAB TO RESIST LATERAL LOAD APPLIED BY PANEL 2) BASE ANGLE GAUGE TO BE DETERMINED BY PROJECT ENGINEER OF RECORD 3) FLOOR INSULATION REQUIRED FOR FREEZER APPLICATIONS BASE DETAIL - INSULATED SLAB HEAVY GAUGE ANGLE

LAP TRIM 2 BEADS OF BUTYL SEALANT ON EACH SIDE SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) "Z" ANGLE LAP TRIM 3" END LAP 3" END LAP SLIP SHEET TO PROTECT PANELS (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT BASE TRIM W/ POP RIVETS @ 8" O.C. SET PANEL IN CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT CONTINUOUS "Z" TRIM SET IN BUTYL SEALANT (SEE LAP TRIM ABOVE FOR "Z" TRIM) HEAVY GA. BASE ANGLE CONTINUOUS HEAVY BEAD OF BUTYL SEALANT FASTENER TO CONCRETE CONCRETE CURB * ENSURE THERMAL BREAK CUT IS DEEP ENOUGH TO CUT METAL AT PANEL JOINT CONCRETE SLAB FIELD CUT THERMAL BREAK FLOOR INSULATION F.I.P INSULATION SUB SLAB REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF BASE CONDITION CONTINUOUS BUTYL SEALANT W/ MARRIAGE BEAD TO VERTICAL PANEL JOINT VAPOR BARRIER NOTES: 1) BASE ANGLE MUST BE FASTENED SECURELY TO SLAB TO RESIST LATERAL LOAD APPLIED BY PANEL 2) Z SHAPED BASE ANGLE GAUGE TO BE DETERMINED BY PROJECT ENGINEER OF RECORD 3) FLOOR INSULATION REQUIRED FOR FREEZER APPLICATIONS BASE DETAIL - INSULATED SLAB LIGHT GAUGE Z

SEALANT(OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) SLIP SHEET TO PROTECT PANELS * ENSURE THERMAL BREAK CUT IS DEEP ENOUGH TO CUT METAL AT PANEL JOINT CONCRETE CURB (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT SET PANEL IN CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT POURABLE SEALANT BASE TRIM 1 4 " - 14 STITCH TEK @ 8" O.C. MIN. 14GA GALVANIZED STEEL BASE CHANNEL CONTINUOUS HEAVY BEAD OF BUTYL SEALANT FASTENER TO CONCRETE CONCRETE SLAB F.I.P INSULATION FIELD CUT THERMAL BREAK STAGGERED FLOOR INSULATION SUB SLAB REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF BASE CONDITION VAPOR BARRIER NOTES: 1) TWO APPLICATIONS OF POURABLE SEALANT ARE REQUIRED. APPLY FIRST APPLICATION AND ALLOW 24HRS BEFORE APPLYING THE SECOND APPLICATION 2) BASE CHANNEL MUST BE FASTENED SECURELY TO SLAB TO RESIST LATERAL LOAD APPLIED BY PANEL 3) FLOOR INSULATION REQUIRED FOR FREEZER APPLICATIONS BASE DETAIL - PARTITION W/ FLOOR INSULATION

* ENSURE THERMAL BREAK CUT IS DEEP ENOUGH TO CUT METAL AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) SLIP SHEET TO PROTECT PANELS (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT SET PANEL IN CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT BASE TRIM POURABLE SEALANT 1 4 " - 14" STITCH TEK @ 8" O.C. MIN. 14GA GALVANIZED STEEL BASE CHANNEL CONTINUOUS HEAVY BEAD OF BUTYL SEALANT FASTENER TO CONCRETE CONCRETE CURB CONCRETE SLAB FIELD CUT THERMAL BREAK F.I.P INSULATION FLOOR INSULATION SUB SLAB REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF BASE CONDITION VAPOR BARRIER NOTES: 1) TWO APPLICATIONS OF POURABLE SEALANT ARE REQUIRED. APPLY FIRST APPLICATION AND ALLOW 24HRS BEFORE APPLYING THE SECOND APPLICATION 2) BASE CHANNEL MUST BE FASTENED SECURELY TO SLAB TO RESIST LATERAL LOAD APPLIED BY PANEL 3) FLOOR INSULATION REQUIRED FOR FREEZER APPLICATIONS BASE DETAIL - INSULATED/ NON-INSULATED FLOOR

CONTINUOUS BUTYL SEALANT AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN) VAPOR BARRIER MAX. 12" O.C. BUTYL SEALANT W/ MARRIAGE BEAD OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) ABUSE CURB (NOT BY KINGSPAN - CAN BE POURED AFTER PANEL INSTALLATION) SLIP SHEET TO PROTECT PANELS BUTYL SEALANT BUTYL SEALANT MIN. 16 GA. GALVANIZED BASE CHANNEL FASTENER TO CONCRETE BASE DETAIL - PARTITION W/ CURBS INSULATED FLOOR

CONTINUOUS BUTYL SEALANT AT PANEL JOINT SLIP SHEET TO PROTECT PANELS SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) CONCRETE CURB CONCRETE CURB FINISH FLOOR CONCRETE SLAB * ENSURE THERMAL BREAK CUT IS DEEP ENOUGH TO CUT METAL AT PANEL JOINT SET PANEL IN CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT BASE CHANNEL F.I.P INSULATION FIELD CUT THERMAL BREAK STAGGERED FLOOR INSULATION SUB SLAB CONTINUOUS HEAVY BEAD OF BUTYL SEALANT FASTENER TO CONCRETE VAPOR BARRIER REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF BASE CONDITION NOTES: 1) BASE CHANNEL MUST BE FASTENED SECURELY TO SLAB 2) ANGLE IRON MAY BE USED IN LIEU OF CHANNEL BASE DETAIL - PARTITION NON-INSULATED FLOOR

OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) MAX. 12" O.C. MIN. 16 GA. GALVANIZED BASE ANGLE CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO SEALANT AT PANEL JOINT MAX. 12" O.C. MIN. 16 GA. GALVANIZED BASE ANGLE FASTENER TO CONCRETE CONCRETE SLAB FASTENER TO CONCRETE BUTYL SEALANT BUTYL SEALANT (OPTIONAL) FLOOR INSULATION VAPOR BARRIER BASE DETAIL - LINER PANEL

OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT @ 8" O.C. BASE TRIM SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN - SEE SCHEDULE) CONTINUOUS BUTYL SEALANT AT PANEL JOINT (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP MIN. 16 GA. GALVANIZED BASE ANGLE BUTYL SEALANT W/ MARRIAGE BEAD TO JOINT SEALANT EXISTING EXTERIOR WALL BUTYL SEALANT (OPTIONAL) SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT FASTENER TO CONCRETE THIS DETAIL ASSUMES MINIMAL TEMPERATURE DIFFERENTIAL ON EITHER SIDE OF PANEL BASE DETAIL - PARTITION W/ CURBS (NON-INSULATED FLOOR)

CONTINUOUS BUTYL SEALANT AT PANEL JOINT OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN) MAX. 12" O.C. BUTYL SEALANT W/ MARRIAGE BEAD TO JOINT SEALANT MAX. 12" O.C. MIN. 16 GA. GALVANIZED BASE ANGLE SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT BUTYL SEALANT (OPTIONAL) FASTENER TO CONCRETE THIS DETAIL ASSUMES MINIMAL TEMPERATURE DIFFERENTIAL ON EITHER SIDE OF PANEL BASE DETAIL - PARTITION W/ CURBS (ALTERNATE)

OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN - SEE SCHEDULE) 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT SLIP SHEET TO PROTECT PANELS (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP ABUSE CURB (NOT BY KINGSPAN - CAN BE POURED AFTER PANEL INSTALLATION) VAPOR BARRIER BUTYL SEALANT BUTYL SEALANT MIN. 16 GA. GALVANIZED BASE ANGLE FASTENER TO CONCRETE SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT PARTITION BASE ON TOP OF CURB

WILL VARY WITH FIELD CONDITION WILL VARY WITH FIELD CONDITION FIELD CUT MIN. 1 4" GAP FOR F.I.P. INSTALLATION FIELD CUT THERMAL BREAK SELF-ADHERING VAPOR BARRIER (AT - NOT BY KINGSPAN) REMOVE METAL SKIN FROM THERMAL CUT TO PANEL END OUTSIDE CORNER TRIM F.I.P. INSULATION 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER @ 8' O.C. INSIDE CORNER TRIM POP RIVETS @ 8" O.C. HORIZONTAL SUPPORT OUTSIDE CORNER - FLUSH TRIM

WILL VARY WITH FIELD CONDITION WILL VARY WITH FIELD CONDITION FIELD CUT MIN. 1 4" GAP FOR F.I.P. INSTALLATION FIELD CUT THERMAL BREAK REMOVE METAL SKIN FROM THERMAL CUT TO PANEL END OUTSIDE CORNER TRIM F.I.P. INSULATION SELF-ADHERING VAPOR BARRIER (AT - NOT BY KINGSPAN) @ 8" O.C. INSIDE CORNER TRIM @ 8" O.C. OUTSIDE CORNER AT PARTITION

FASTENER TO CONCRETE OUTSIDE CORNER TRIM (PRE-INSTALL) TRANS FLASHING SELF-ADHERING VAPOR BARRIER (AT "WARM" - NOT BY KINGSPAN) FIELD CUT THERMAL BREAK REMOVE METAL SKIN FROM THERMAL CUT TO PANEL END INSIDE CORNER TRIM 3 4 " PHIL. PAN HEAD @ 8" O.C. F.I.P. INSULATION @ 8" O.C. OUTSIDE CORNER LINER PANEL AT CONC WALL

WILL VARY WITH FIELD CONDITION WILL VARY WITH FIELD CONDITION FIELD CUT @ 8" O.C. CONTINUOUS BUTYL SEALANT OUTSIDE CORNER TRIM 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER W/ 1 1 8" BONDED WASHER FIELD CUT THERMAL BREAK REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF CORNER CONDITION F.I.P. INSULATION MIN. 1 4" GAP FOR F.I.P. INSTALLATION 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER W/ 1 1 8" BONDED WASHER @ 8" O.C. HORIZONTAL SUPPORT POP RIVETS @ 8" O.C. SELF-ADHERING VAPOR BARRIER INSIDE CORNER TRIM POP RIVETS @ 8" O.C. INSIDE CORNER - FLUSH TRIM

INTERIOR @ 8" O.C. EXTERIOR SELF-ADHERING VAPOR BARRIER INSIDE CORNER TRIM FIELD CUT THERMAL BREAK @ 8" O.C. INTERIOR PARTITION F.I.P. INSULATION EXPANSION FASTENER (TO BE LOCATED ON OPPOSITE SIDE OF THERMAL CUT FROM PANEL'S LEADING EDGE) OPTIONAL BUTYL AT WASH DOWN INSIDE CORNER TRIM @ 8" O.C. STRUCTURAL SUPPORT INTERIOR NOTES: 1) ADDITIONAL FASTENERS MAY BE REQUIRED ON EITHER SIDE OF THE FIELD CUT THERMAL BREAK BASED UPON ACTUAL DESIGN LOADS AND THERMAL REQUIREMENTS FIELD FILL WITH INSULATION INSULATE SUPPORTING STEEL ON OF PARTITION (APPROX. 4'-0") FIELD NOTCH PANELS AT GIRT LOCATIONS GIRT CAP TRIM PARTITION TO EXTERIOR WALL

OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) FREEZER DOOR CASING, FASTENERS, SEALANT, & REQUIRED SUPPORT SELF ADHERING VAPOR BARRIER (OPTIONAL - NOT BY KINGSPAN) CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO SEALANT AT PANEL JOINT HEADER CONDITION

SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) SELF ADHERING VAPOR BARRIER (OPTIONAL - NOT BY KINGSPAN) FREEZER DOOR CASING, FASTENERS, SEALANT, & REQUIRED SUPPORT CONTINUOUS BUTYL SEALANT JAMB CONDITION

FIELD ROUT PANELS FOR WOOD SPLINE BASE TRIM WITH POP RIVETS (PRE-INSTALL WEEP HOLES) CONTINUOUS BUTYL SEALANT FIR SPLINE STACK JOINT TRIM WITH POP RIVETS SET FIR SPLINE IN BUTYL SEALANT CONTINUOUS BUTYL SEALANT MARRIED TO SEALANT IN PANEL JOINT CONTINUOUS BUTYL SEALANT AT PANEL JOINT HORIZONTAL SUPPORT 14 GA. GALVANIZED HIDDEN CLIP (1 PER PANEL, PER GIRT) NOTES: 1) SEE DETAIL CS-TL-01-KSV AND CS-TL-02-KSV FOR PROPER TRIM LAP DETAILS 2) CONTACT KINGSPAN TECHNICAL SERVICES FOR PROPER PANEL FASTENING REQUIREMENTS STACK JOINT

GALVANIZED CAP FLASHING ROOF MEMBRANE SYSTEM ATTACHMENT ROOF MEMBRANE BOARD INSULATION AND ROOF UNDERLAYMENT ROOF MEMBRANE SYSTEM ATTACHMENT SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT RAKE TRIM, FASTENERS, SEALANT AND WEATHER TIGHTNESS FIELD CUT THERMAL BREAK SHEETING OR RAKE ANGLE REQUIRED F.I.P. INSULATION OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT CONTINUOUS BUTYL SEALANT AT PANEL JOINT RAKE

GALVANIZED CAP FLASHING ROOF MEMBRANE ROOF MEMBRANE SYSTEM ATTACHMENT CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT INSULATION AND ROOF UNDERLAYMENT FASTENER RAKE TRIM, FASTENERS, SEALANT AND WEATHER TIGHTNESS SEALANT TO MEMBRANE FIELD CUT THERMAL BREAK F.I.P. INSULATION SHEETING OR RAKE ANGLE REQUIRED 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) RAKE W/ MEMBRANE ROOF

F.I.P. INSULATION GALVANIZED CAP FLASHING ROOF MEMBRANE ROOF MEMBRANE SYSTEM ATTACHMENT CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT INSULATION AND ROOF UNDERLAYMENT FASTENER RAKE TRIM, FASTENERS, SEALANT AND WEATHER TIGHTNESS SEALANT TO MEMBRANE FIELD CUT THERMAL BREAK EAVE STRUT OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT CONTINUOUS BUTYL SEALANT AT PANEL JOINT LOW EAVE

SEE CS-CE-04-KSV FOR ADDITIONAL INFO FIELD CUT THERMAL BREAK ATTIC ABOVE CEILING MUST BE VENTILATED F.I.P. INSULATION OUTSIDE CORNER TRIM CEILING SELF ADHERING VAPOR BARRIER WALL INSIDE CORNER TRIM CONTINUOUS BUTYL SEALANT AT PANEL JOINT INTERIOR WALL TO CEILING

#10 X 1 3 8" FASTENER AT EVERY PANEL JOINT BOTH SIDES OF PANEL AA CROSS SECTION (SECTION VIEW ) FIELD CUT THERMAL BREAK CEILING BUTYL SEALANT SUPPORT ANGLE EXPANSION FASTENER COMPRESSIBLE INSULATION A WALL A BUTYL SEALANT #10 X 1 3 8" TEK 1 FASTENER AT EVERY PANEL JOINT (SEE DETAIL ABOVE) WALL TO CEILING INTERSECTION

ATTIC ABOVE CEILING MUST BE VENTILATED INSULATE HANGER RODS AS REQUIRED (NOT BY KINGSPAN) 3 8 " GALVANIZED HANGER ALL-THREAD ROD (ROD SPACING TO BE DETERMINED) TRANSITION FLASHING HEX NUT AND LOCK WASHER 4" X 4" X 14 GA. PLATE WASHER* SELF ADHERING VAPOR BARRIER INTERIOR FACE OF PANEL CEILING CEILING FILL 1 2" GAP BETWEEN PANEL WITH F.I.P. INSULATION HEX NUT AND LOCK WASHER EXTERIOR SIDE OF PANEL MUST BE ON BOTTOM OF CEILING. PANEL CUTLIST MUST MATCH THIS ORIENTATION 1 1 2" X 6" X 14 GA. GALVANIZED CEILING CHANNEL (WHITE POWDER COAT - OPTIONAL) (CAP TRIM - OPTIONAL) #8 GA. SPLAY BRACE WIRE IN FOUR DIRECTIONS 3 8 " ALL-THREAD HANGER ROD FOUR TIGHT TURNS IN 1 1 2" SEISMIC BRACE PLATE * CONTACT KINGSPAN TECHNICAL SERVICES FOR SEISMIC BRACE PLATE QUANTITY AND LOCATION SEISMIC BRACE PLATE CEILING CHANNEL

ATTIC ABOVE CEILING MUST BE VENTILATED 3 8 " GALVANIZED HANGER ALL-THREAD ROD (SPACED NO GREATER THAN 6'-0" O.C.) TRANSITION FLASHING INSULATE HANGER RODS AS REQUIRED (NOT BY KINGSPAN) HEX NUT AND LOCK WASHER 4" X 4" X 14 GA. PLATE WASHER* SELF-ADHERING VAPOR BARRIER INTERIOR FACE OF PANEL CEILING CEILING EXTERIOR SIDE OF PANEL MUST BE ON BOTTOM OF CEILING. PANEL CUTLIST MUST MATCH THIS ORIENTATION 4" X 3" X 3 16" EXTRUDED ALUMINUM CEILING TEE (WHITE POWDER COAT FINISH) FILL 1 2" GAP BETWEEN PANEL WITH F.I.P. INSULATION 3 8 "Ø EYE COUPLER NUT 3 8 "Ø x 1 1 2" BOLT WITH (3) 3 8 " WASHERS AND (1) LOCK-NUT PER BOLT BUTYL SEALANT #8 GA. SPLAY BRACE WIRE IN FOUR DIRECTIONS 3 8 " ALL-THREAD HANGER ROD FOUR TIGHT TURNS IN 1 1 2" SEISMIC BRACE PLATE * CONTACT KINGSPAN TECHNICAL SERVICES FOR SEISMIC BRACE PLATE QUANTITY AND LOCATION SEISMIC BRACE PLATE CEILING TEE

SEISMIC BRACE PLATE (IF REQUIRED) TO BE LOCATED AT EVERY THIRD ROD LOCATION IN LIEU OF PLATE WASHER (SEE DETAIL CS-CE-04-KSV). CONTACT KINGSPAN TECHNICAL SERVICES FOR VERIFICATION. OUTSIDE CORNER TRIM WITH @ 12" OC. (SEALANT OR VAPOR SEAL TAPE AS REQUIRED) SEE DETAIL CS-CE-01-KSV FOR ADD'L INFO. PROJECT ENGINEER OF RECORD MUST VERIFY ROOF IS CAPABLE OF SUPPORTING CEILING SYSTEM LOADS AS WELL AS PROPER CEILING TO ROOF CONNECTION DETAILS LOCATE FIRST HANGER ROD AT LESS THAN 24" FROM FACE OF PANEL ERECTOR MAY PRE-ASSEMBLE HARDWARE ON 3 8" HANGAR RODS- WIRE TIES HOLD WASHERS ABOVE WORKING POINT CEILING TEE HEX NUT ROUND WSHR SPLICE PLATE 4" X 4" X 14 GA. PLATE WASHER WIRE TIE INTERIOR FACE OF PANEL CEILING TEE CEILING TEE SPLICE PLATE W/ (4) 3 8" X 1 1 2" BOLTS, NUTS, AND WASHERS EXTERIOR SIDE OF PANEL MUST BE ON BOTTOM OF CEILING. PANEL CUTLIST MUST MATCH THIS ORIENTATION CEILING TEE ASSEMBLY

PROJECT ENGINEER OF RECORD MUST VERIFY ROOF IS CAPABLE OF SUPPORTING CEILING SYSTEM LOADS AS WELL AS PROPER CEILING TO ROOF CONNECTION DETAILS FIELD NOTCH END OF CHANNEL TO REST ON TOP OF WALL PANEL NUT ROUND WSHR ERECTOR MAY PRE-ASSEMBLE HARDWARE ON 3/8" HANGER RODS- WIRE TIES HOLD WASHERS ABOVE WORKING POINT 4" X 4" X 14 GA. PLATE WASHER WIRE TIE 2'-0" MAX. INTERIOR FACE OF PANEL SPLICE PLATE CEILING CHANNEL 9/16" DIA. HOLES PRE-PUNCHED FOR 3/8" OR ALL-THREAD ROD AT 5'-0" O/C (DO NOT SPACE ALL-THREAD RODS FURTHER THAN 60" APART. THE SPAN FROM WALL TO FIRST ROD, SHALL BE NO GREATER THAN 24".) EXTERIOR SIDE OF PANEL MUST BE ON BOTTOM OF CEILING. PANEL CUTLIST MUST MATCH THIS ORIENTATION CEILING CHANNEL ASSEMBLY

ATTIC ABOVE CEILING MUST BE VENTILATED BUTYL SEALANT INSIDE CORNER TRIM FIELD CUT THERMAL BREAK F.I.P. INSULATION EXPANSION FASTENER CEILING CONTINUOUS BUTYL SEALANT AT "WARM" SIDE PANEL JOINT SUPPORT ANGLE NOTE: CONTACT KINGSPAN TECHNICAL SERVICES FOR ENGINEERING ASSISTANCE CEILING TO WALL - LONGITUDINAL

ATTIC ABOVE CEILING MUST BE VENTILATED 3 8 " GALVANIZED HANGER ALL-THREAD ROD (ROD SPACING TO BE DETERMINED) BUTYL SEALANT INSIDE CORNER TRIM 1 4 " MAX DISTANCE BETWEEN PANEL EDGE AND THREAD ROD FIELD CUT THERMAL BREAK F.I.P. INSULATION EXPANSION FASTENER CEILING CONTINUOUS BUTYL SEALANT AT "WARM" SIDE PANEL JOINT 16 GA. SUPPORT ANGLE HEX NUT AND LOCK WASHER NOTE: CONTACT KINGSPAN TECHNICAL SERVICES FOR ENGINEERING ASSISTANCE CEILING TO WALL - TRANSVERSE

A EXPANSION FASTENERS AS REQUIRED COMPRESSIBLE INSULATION SUPPORT ANGLE (SET IN BUTYL SEALANT) #10 X 1 3 8" TEK 1 FASTENER AT EVERY PANEL JOINT A PARTITION TO ROOF (PERPENDICULAR TO PURLIN) FIELD FILL WITH INSULATION FIELD NOTCH PANELS AT PURLIN LOCATIONS KINGSPAN TO SUPPLY FLAT-STOCK SHEETING TO BE FIELD FORMED FOR PANEL CLOSURES COMPRESSIBLE INSULATION PURLIN AA CROSS SECTION (SECTION VIEW -- TYPICAL AT EACH PURLIN) PARTITION TO ROOF

FILL VOIDS WITH FOAM BLOCK, SET IN BUTYL SEALANT FIELD CUT PANELS AS REQUIRED 1/4"-14 STITCH TEKS AT EACH PURLIN PURLIN CLOSURE TRIM TO BE FIELD CUT TO FIT AT PURLIN FLANGES. USE SILICONE TO SEAL ALL EDGES WHEN COMPLETE. 1/4"-14 STITCH TEKS AT EACH PURLIN SUPPORT ANGLE (SET IN BUTYL SEALANT) ATTACH PURLIN CLOSURES W/ POP RIVETS COMPRESSIBLE INSULATION PARTITION TO ROOF (WITH FOAM BLOCKING) (PERPENDICULAR TO PURLIN) #10 X 1 3 8" TEK 1 FASTENER AT EVERY PANEL JOINT FIELD CUT CONTINUOUS THERMAL BREAK (FREEZER ONLY) COMPRESSIBLE INSULATION EXPANSION FASTENERS AS REQUIRED SUPPORT ANGLE SET IN BUTYL SEALANT PARTITION TO ROOF (PARALLEL TO PURLIN) #10 X 1 3 8" TEK 1 FASTENER AT EVERY PANEL JOINT PARTITION TO ROOF WITH BLOCKING

(2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP MIN. 3" TRIM LAP TRIM END LAP

FIELD NOTCH HEM(S) AS REQUIRED MIN. 3" TRIM LAP (2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP TRIM LAP WITH HEM

(2) BEADS BUTYL SEALANT 8" LONG LAP STRIP NOM. 1 4 " GAP TRIM END LAP WITH LAP STRIP

NOTE: DETAIL SHOWN IS FOR GENERAL USE ONLY (NOT FOR COOLER/FREEZER APPLICATIONS). SEALANT END DAM 2 INTERIOR HEAD TRIM WITH TABS BENT DOWN FIELD NOTCH AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY FIELD MITER AND OVERLAP TRIMS, POP RIVET AS NECESSARY INTERIOR CAP TRIM AT HEAD EXPOSED SEALANT EXTERIOR CAP TRIM AT HEAD 5 EXTERIOR HEAD TRIM W/ FIELD DRILL 3 8" Ø WEEP HOLES INTERIOR JAMB TRIM 1 SILL TRIM WITH TABS BENT UP 6 3 EXTERIOR CAP TRIM AT JAMB FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP 4 EXTERIOR JAMB TRIM FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP EXTERIOR CAP TRIM AT SILL FIELD MITER AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY TRIM INSTALLATION SEQUENCE: 1 INTERIOR JAMB TRIM 2 INTERIOR HEAD TRIM WITH TABS DOWN 3 SILL TRIM WITH TABS UP 4 EXTERIOR JAMB TRIM 5 EXTERIOR HEAD TRIM 6 EXTERIOR SEALANTS AS REQUIRED TRIM LAP AT FRAMED OPENING