CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV KS 45 EXPANDED PANEL JOINT CS-PJ-04-KSV KS 45 ENGAGED PANEL JOINT CS-PJ-05-KSV INTERMEDIATE SUPPORT CS-PJ-06-KSV LINER PANEL TO CONCRETE WITH SUPPORT CS-PJ-07-KSV LINER PANEL TO CONCRETE CS-BS-01-KSV BASE DETAIL - INSULATED SLAB HEAVY GAUGE ANGLE CS-BS-02-KSV BASE DETAIL - INSULATED SLAB LIGHT GAUGE Z CS-BS-03-KSV BASE DETAIL - PARTITION W/ FLOOR INSULATION CS-BS-04-KSV BASE DETAIL - INSULATED/NON-INSULATED CS-BS-05-KSV BASE DETAIL - PART. W/ CURBS INSULATED CS-BS-06-KSV BASE DETAIL - PART. NON-INSULATED CS-BS-07-KSV BASE DETAIL - LINER PANEL CS-BS-08-KSV BASE DETAIL - PART. W/ CURBS NON-INSULATED CS-BS-09-KSV BASE DETAIL - PART. W/ CURBS (ALTERNATE) CS-BS-10-KSV PARTITION BASE ON TOP OF CURB CS-OC-01-KSV OUTSIDE CORNER - FLUSH TRIM CS-OC-02-KSV OUTSIDE CORNER AT PARTITION CS-OC-03-KSV OUTSIDE CORNER LINER PANEL AT CONC WALL INDEX SHEET
CS-IC-01-KSV CS-IC-02-KSV CS-FO-01-KSV CS-FO-02-KSV CS-ST-01-KSV CS-RK-01-KSV CS-RK-02-KSV CS-EV-01-KSV CS-CE-01-KSV CS-CE-02-KSV CS-CE-03-KSV CS-CE-04-KSV CS-CE-05-KSV CS-CE-06-KSV CS-CE-07-KSV CS-CE-08-KSV CS-CE-09-KSV CS-CE-10-KSV CS-TL-01-KSV CS-TL-02-KSV CS-TL-03-KSV CS-TL-04-KSV INSIDE CORNER - FLUSH TRIM PARTITION TO EXTERIOR WALL HEADER CONDITION JAMB CONDITION STACK JOINT RAKE RAKE W/ MEMBRANE ROOF LOW EAVE INTERIOR WALL TO CEILING INTERIOR WALL TO CEILING - 'T' SECTION CEILING CHANNEL CEILING TEE CEILING TEE ASSEMBLY CEILING CHANNEL ASSEMBLY CEILING TO WALL - LONGITUDINAL CEILING TO WALL - TRANSVERSE PARTITION TO ROOF PARTITION TO ROOF WITH BLOCKING TRIM END LAP TRIM LAP WITH HEM TRIM END LAP WITH LAP STRIP TRIM LAP AT FRAMED OPENING INDEX SHEET
DISCLAIMERS: THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. REFRIGERATION EQUIPMENT IN COMBINATION WITH THE TEMPERATURE DIFFERENTIAL BETWEEN BUILDING EXTERIOR AND INTERIOR CAN CREATE NEGATIVE AIR PRESSURE WITHIN THE BUILDING (WARM AIR FROM OUTSIDE THE BUILDING IS DRAWN INTO THE BUILDING THROUGH AIR LEAKS IN THE BUILDING ENVELOPE). AS A RESULT, VAPOR SEALS ARE OF PRIMARY CONCERN TO PROPER COLD STORAGE PERFORMANCE. IN GENERAL, COLD STORAGE FACILITIES REQUIRE THE PRIMARY VAPOR BARRIER TO BE ON THE EXTERIOR (I.E. ), RATHER THAN INTERIOR SIDE OF THE PANEL. PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS. ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION AND ILLUSTRATION PURPOSES ONLY. CONTACT KINGSPAN TECHNICAL SERVICES FOR MAXIMUM ALLOWABLE PANEL SPANS AND FASTENING PATTERNS. ALL SEALANTS TO BE COMPATIBLE WITH VAPOR BARRIERS AS SHOWN COLD STORAGE DISCLAIMER
CORE DEPTHS: 2", 2.5", 3", 4", 5", 6" STEEL GAUGES: EXTERIOR: (REFER TO PROFILE) INTERIOR: 26, 24, 22 MODULE WIDTH: 24", 30", 36", 42" PANEL ORIENTATION: VERTICAL EMBOSSING: EXTERIOR: STUCCO / SMOOTH* INTERIOR: STUCCO / SMOOTH LENGTHS: MINIMUM: 8'-0" MAXIMUM: 53'-0" FEMALE JOINT INTERIOR FACE KS MINI WAVE (MW) SHADOWLINE MALE JOINT 2" - 6" EXTERIOR FACE MINI-WAVE (24GA, 22GA ONLY) 42" COVERAGE (36", 30", & 24" OPTIONAL) SHADOWLINE INTERIOR FACE FEMALE JOINT KS SL FLAT EXTERIOR FACE FLAT (26GA, 24GA, 22GA) 42" COVERAGE (36", 30", & 24" OPTIONAL) MALE JOINT 2" - 6" SHADOWLINE INTERIOR FACE FEMALE JOINT KS GRANITSTONE/QUARTZ (GS) EXTERIOR FACE GRANITSTONE / QUARTZ (24GA, 22GA ONLY) 42" COVERAGE (36", 30", & 24" OPTIONAL) MALE JOINT 2" - 6" INTERIOR FACE SHADOWLINE or FLAT EXTERIOR FACE (22GA ONLY) KS OPTIMO (OPE or OPS) 40" COVERAGE (24", 30", 36" OPTIONAL) OPTIONAL TRIMLESS ENDS FLAT 2" - 4" NOTE: MAX LENGTH: EMBOSSED: 32'-0" SMOOTH: 20'-0" KS SERIES PANEL PROFILES
CORE DEPTHS: 2", 2.5", 3", 4", 5", 6" STEEL GAUGES: EXTERIOR: (REFER TO PROFILE) INTERIOR: 26, 24, 22 MODULE WIDTH: 24", 30", 36", 42" PANEL ORIENTATION: VERTICAL EMBOSSING: EXTERIOR: STUCCO / SMOOTH* INTERIOR: STUCCO / SMOOTH LENGTHS: MINIMUM: 8'-0" MAXIMUM: 53'-0" FEMALE JOINT INTERIOR FACE KS MINI WAVE (MW) SHADOWLINE MALE JOINT 2" - 6" EXTERIOR FACE MINI-WAVE (24GA, 22GA ONLY) 42" COVERAGE (36", 30", & 24" OPTIONAL) SHADOWLINE INTERIOR FACE FEMALE JOINT KS SL FLAT EXTERIOR FACE FLAT (26GA, 24GA, 22GA) 42" COVERAGE (36", 30", & 24" OPTIONAL) MALE JOINT 2" - 6" INTERIOR FACE SHADOWLINE FEMALE JOINT KS GRANITSTONE/QUARTZ (GS) EXTERIOR FACE (24GA, 22GA ONLY) GRANITSTONE / QUARTZ 42" COVERAGE (36", 30", & 24" OPTIONAL) MALE JOINT 2" - 6" INTERIOR FACE SHADOWLINE or FLAT EXTERIOR FACE (22GA ONLY) KS OPTIMO (OPE or OPS) 40" COVERAGE (24", 30", 36" OPTIONAL) OPTIONAL TRIMLESS ENDS FLAT 2" - 4" NOTE: MAX LENGTH: EMBOSSED: 32'-0" SMOOTH: 20'-0" KS SERIES PANEL PROFILES
CORE DEPTHS: 2", 2.75", 3", 4", 5", 6", 8" STEEL GAUGES: EXTERIOR:26, 24, 22 INTERIOR: 26, 24, 22 MODULE WIDTH: 45.375" (45 3 8") PANEL ORIENTATION: VERTICAL EMBOSSING: EXTERIOR: STUCCO / SMOOTH INTERIOR: STUCCO / SMOOTH LENGTHS: MINIMUM: 8'-0" MAXIMUM: 53'-0" INTERIOR FACE SHADOWLINE MALE JOINT FEMALE JOINT EXTERIOR FACE KS SHADOWLINE INTERIOR (KSSLI) SHADOWLINE 2"-8" 45.375" (45 3 8") KS SERIES PANEL PROFILES
HORIZONTAL SUPPORT MALE LEG FEMALE POCKET 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT (2) 1 4" - 14 HEX HEAD FASTENERS WITHOUT WASHER OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT (AT "WARM" SIDE JOINT) WALL PANEL INSTALLATION DIRECTION NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL * VERIFY FIRST PANEL ENGAGEMENT AND ADJUST ACCORDINGLY KS SERIES EXPANDED JOINT
HORIZONTAL SUPPORT MALE JOINT FEMALE JOINT PANEL MODULE 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT (2) 1 4" - 14 HEX HEAD FASTENERS WITHOUT WASHER 1 8 " OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT (AT JOINT) WALL PANEL INSTALLATION DIRECTION KS SERIES ENGAGED JOINT
OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) MALE LEG FEMALE POCKET CONTINUOUS BUTYL SEALANT (AT "WARM" SIDE JOINT) WALL PANEL INSTALLATION DIRECTION NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL * VERIFY FIRST PANEL ENGAGEMENT AND ADJUST ACCORDINGLY KS 45 SERIES EXPANDED JOINT
(SPACING AS REQUIRED PER PANEL ANALYSIS) OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT (AT JOINT) (SPACING AS REQUIRED PER PANEL ANALYSIS) WALL PANEL INSTALLATION DIRECTION KS 45 SERIES ENGAGED JOINT
OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) MALE LEG FEMALE POCKET CONTINUOUS BUTYL SEALANT (AT "WARM" SIDE JOINT) WALL PANEL INSTALLATION DIRECTION NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL * VERIFY FIRST PANEL ENGAGEMENT AND ADJUST ACCORDINGLY INTERMEDIATE SUPPORT
(SPACING AS REQUIRED PER PANEL ANALYSIS) OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT (AT JOINT) (SPACING AS REQUIRED PER PANEL ANALYSIS) WALL PANEL INSTALLATION DIRECTION LINER PANEL TO CONCRETE WITH SUPPORT
OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) INTERIOR OF BUILDING EXTERIOR OF BUILDING CONTINUOUS BUTYL SEALANT AT PANEL JOINT STRUCTURAL FRAMING (2) 1 4" - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT 2 1 4 " 1" 3 4 " 2 1 4 " 3 4 " 5 16 " Ø 5 16 " Ø STANDARD: 12 GA. STAINLESS STEEL TWO-HOLE HIDDEN FASTENER CLIP OPTIONAL: 12 GA. STAINLESS STEEL ONE-HOLE HIDDEN FASTENER CLIP NOTE: CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS LINER PANEL TO CONCRETE
"Z" TRIM 2 BEADS OF BUTYL SEALANT ON EACH SIDE "Z" TRIM LAP TRIM MIN. 3" TRIM LAP SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) SLIP SHEET TO PROTECT PANELS HEAVY GA. BASE ANGLE CONTINUOUS HEAVY BEAD OF BUTYL SEALANT FASTENER TO CONCRETE (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT BASE TRIM W/ POP RIVETS @ 8" O.C. SET PANEL IN CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT CONTINUOUS "Z" TRIM SET IN BUTYL SEALANT (SEE LAP TRIM ABOVE FOR "Z" TRIM) CONCRETE CURB * ENSURE THERMAL BREAK CUT IS DEEP ENOUGH TO CUT METAL AT PANEL JOINT CONCRETE SLAB FIELD CUT THERMAL BREAK FLOOR INSULATION F.I.P INSULATION SUB SLAB REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF BASE CONDITION CONTINUOUS BUTYL SEALANT W/ MARRIAGE BEAD TO VERTICAL PANEL JOINT VAPOR BARRIER NOTES: 1) BASE ANGLE MUST BE FASTENED SECURELY TO SLAB TO RESIST LATERAL LOAD APPLIED BY PANEL 2) BASE ANGLE GAUGE TO BE DETERMINED BY PROJECT ENGINEER OF RECORD 3) FLOOR INSULATION REQUIRED FOR FREEZER APPLICATIONS BASE DETAIL - INSULATED SLAB HEAVY GAUGE ANGLE
LAP TRIM 2 BEADS OF BUTYL SEALANT ON EACH SIDE SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) "Z" ANGLE LAP TRIM 3" END LAP 3" END LAP SLIP SHEET TO PROTECT PANELS (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT BASE TRIM W/ POP RIVETS @ 8" O.C. SET PANEL IN CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT CONTINUOUS "Z" TRIM SET IN BUTYL SEALANT (SEE LAP TRIM ABOVE FOR "Z" TRIM) HEAVY GA. BASE ANGLE CONTINUOUS HEAVY BEAD OF BUTYL SEALANT FASTENER TO CONCRETE CONCRETE CURB * ENSURE THERMAL BREAK CUT IS DEEP ENOUGH TO CUT METAL AT PANEL JOINT CONCRETE SLAB FIELD CUT THERMAL BREAK FLOOR INSULATION F.I.P INSULATION SUB SLAB REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF BASE CONDITION CONTINUOUS BUTYL SEALANT W/ MARRIAGE BEAD TO VERTICAL PANEL JOINT VAPOR BARRIER NOTES: 1) BASE ANGLE MUST BE FASTENED SECURELY TO SLAB TO RESIST LATERAL LOAD APPLIED BY PANEL 2) Z SHAPED BASE ANGLE GAUGE TO BE DETERMINED BY PROJECT ENGINEER OF RECORD 3) FLOOR INSULATION REQUIRED FOR FREEZER APPLICATIONS BASE DETAIL - INSULATED SLAB LIGHT GAUGE Z
SEALANT(OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) SLIP SHEET TO PROTECT PANELS * ENSURE THERMAL BREAK CUT IS DEEP ENOUGH TO CUT METAL AT PANEL JOINT CONCRETE CURB (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT SET PANEL IN CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT POURABLE SEALANT BASE TRIM 1 4 " - 14 STITCH TEK @ 8" O.C. MIN. 14GA GALVANIZED STEEL BASE CHANNEL CONTINUOUS HEAVY BEAD OF BUTYL SEALANT FASTENER TO CONCRETE CONCRETE SLAB F.I.P INSULATION FIELD CUT THERMAL BREAK STAGGERED FLOOR INSULATION SUB SLAB REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF BASE CONDITION VAPOR BARRIER NOTES: 1) TWO APPLICATIONS OF POURABLE SEALANT ARE REQUIRED. APPLY FIRST APPLICATION AND ALLOW 24HRS BEFORE APPLYING THE SECOND APPLICATION 2) BASE CHANNEL MUST BE FASTENED SECURELY TO SLAB TO RESIST LATERAL LOAD APPLIED BY PANEL 3) FLOOR INSULATION REQUIRED FOR FREEZER APPLICATIONS BASE DETAIL - PARTITION W/ FLOOR INSULATION
* ENSURE THERMAL BREAK CUT IS DEEP ENOUGH TO CUT METAL AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) SLIP SHEET TO PROTECT PANELS (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT SET PANEL IN CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT BASE TRIM POURABLE SEALANT 1 4 " - 14" STITCH TEK @ 8" O.C. MIN. 14GA GALVANIZED STEEL BASE CHANNEL CONTINUOUS HEAVY BEAD OF BUTYL SEALANT FASTENER TO CONCRETE CONCRETE CURB CONCRETE SLAB FIELD CUT THERMAL BREAK F.I.P INSULATION FLOOR INSULATION SUB SLAB REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF BASE CONDITION VAPOR BARRIER NOTES: 1) TWO APPLICATIONS OF POURABLE SEALANT ARE REQUIRED. APPLY FIRST APPLICATION AND ALLOW 24HRS BEFORE APPLYING THE SECOND APPLICATION 2) BASE CHANNEL MUST BE FASTENED SECURELY TO SLAB TO RESIST LATERAL LOAD APPLIED BY PANEL 3) FLOOR INSULATION REQUIRED FOR FREEZER APPLICATIONS BASE DETAIL - INSULATED/ NON-INSULATED FLOOR
CONTINUOUS BUTYL SEALANT AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN) VAPOR BARRIER MAX. 12" O.C. BUTYL SEALANT W/ MARRIAGE BEAD OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) ABUSE CURB (NOT BY KINGSPAN - CAN BE POURED AFTER PANEL INSTALLATION) SLIP SHEET TO PROTECT PANELS BUTYL SEALANT BUTYL SEALANT MIN. 16 GA. GALVANIZED BASE CHANNEL FASTENER TO CONCRETE BASE DETAIL - PARTITION W/ CURBS INSULATED FLOOR
CONTINUOUS BUTYL SEALANT AT PANEL JOINT SLIP SHEET TO PROTECT PANELS SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) CONCRETE CURB CONCRETE CURB FINISH FLOOR CONCRETE SLAB * ENSURE THERMAL BREAK CUT IS DEEP ENOUGH TO CUT METAL AT PANEL JOINT SET PANEL IN CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT BASE CHANNEL F.I.P INSULATION FIELD CUT THERMAL BREAK STAGGERED FLOOR INSULATION SUB SLAB CONTINUOUS HEAVY BEAD OF BUTYL SEALANT FASTENER TO CONCRETE VAPOR BARRIER REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF BASE CONDITION NOTES: 1) BASE CHANNEL MUST BE FASTENED SECURELY TO SLAB 2) ANGLE IRON MAY BE USED IN LIEU OF CHANNEL BASE DETAIL - PARTITION NON-INSULATED FLOOR
OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) MAX. 12" O.C. MIN. 16 GA. GALVANIZED BASE ANGLE CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO SEALANT AT PANEL JOINT MAX. 12" O.C. MIN. 16 GA. GALVANIZED BASE ANGLE FASTENER TO CONCRETE CONCRETE SLAB FASTENER TO CONCRETE BUTYL SEALANT BUTYL SEALANT (OPTIONAL) FLOOR INSULATION VAPOR BARRIER BASE DETAIL - LINER PANEL
OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT @ 8" O.C. BASE TRIM SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN - SEE SCHEDULE) CONTINUOUS BUTYL SEALANT AT PANEL JOINT (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP MIN. 16 GA. GALVANIZED BASE ANGLE BUTYL SEALANT W/ MARRIAGE BEAD TO JOINT SEALANT EXISTING EXTERIOR WALL BUTYL SEALANT (OPTIONAL) SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT FASTENER TO CONCRETE THIS DETAIL ASSUMES MINIMAL TEMPERATURE DIFFERENTIAL ON EITHER SIDE OF PANEL BASE DETAIL - PARTITION W/ CURBS (NON-INSULATED FLOOR)
CONTINUOUS BUTYL SEALANT AT PANEL JOINT OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN) MAX. 12" O.C. BUTYL SEALANT W/ MARRIAGE BEAD TO JOINT SEALANT MAX. 12" O.C. MIN. 16 GA. GALVANIZED BASE ANGLE SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT BUTYL SEALANT (OPTIONAL) FASTENER TO CONCRETE THIS DETAIL ASSUMES MINIMAL TEMPERATURE DIFFERENTIAL ON EITHER SIDE OF PANEL BASE DETAIL - PARTITION W/ CURBS (ALTERNATE)
OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN - SEE SCHEDULE) 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT SLIP SHEET TO PROTECT PANELS (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP ABUSE CURB (NOT BY KINGSPAN - CAN BE POURED AFTER PANEL INSTALLATION) VAPOR BARRIER BUTYL SEALANT BUTYL SEALANT MIN. 16 GA. GALVANIZED BASE ANGLE FASTENER TO CONCRETE SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT PARTITION BASE ON TOP OF CURB
WILL VARY WITH FIELD CONDITION WILL VARY WITH FIELD CONDITION FIELD CUT MIN. 1 4" GAP FOR F.I.P. INSTALLATION FIELD CUT THERMAL BREAK SELF-ADHERING VAPOR BARRIER (AT - NOT BY KINGSPAN) REMOVE METAL SKIN FROM THERMAL CUT TO PANEL END OUTSIDE CORNER TRIM F.I.P. INSULATION 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER @ 8' O.C. INSIDE CORNER TRIM POP RIVETS @ 8" O.C. HORIZONTAL SUPPORT OUTSIDE CORNER - FLUSH TRIM
WILL VARY WITH FIELD CONDITION WILL VARY WITH FIELD CONDITION FIELD CUT MIN. 1 4" GAP FOR F.I.P. INSTALLATION FIELD CUT THERMAL BREAK REMOVE METAL SKIN FROM THERMAL CUT TO PANEL END OUTSIDE CORNER TRIM F.I.P. INSULATION SELF-ADHERING VAPOR BARRIER (AT - NOT BY KINGSPAN) @ 8" O.C. INSIDE CORNER TRIM @ 8" O.C. OUTSIDE CORNER AT PARTITION
FASTENER TO CONCRETE OUTSIDE CORNER TRIM (PRE-INSTALL) TRANS FLASHING SELF-ADHERING VAPOR BARRIER (AT "WARM" - NOT BY KINGSPAN) FIELD CUT THERMAL BREAK REMOVE METAL SKIN FROM THERMAL CUT TO PANEL END INSIDE CORNER TRIM 3 4 " PHIL. PAN HEAD @ 8" O.C. F.I.P. INSULATION @ 8" O.C. OUTSIDE CORNER LINER PANEL AT CONC WALL
WILL VARY WITH FIELD CONDITION WILL VARY WITH FIELD CONDITION FIELD CUT @ 8" O.C. CONTINUOUS BUTYL SEALANT OUTSIDE CORNER TRIM 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER W/ 1 1 8" BONDED WASHER FIELD CUT THERMAL BREAK REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF CORNER CONDITION F.I.P. INSULATION MIN. 1 4" GAP FOR F.I.P. INSTALLATION 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER W/ 1 1 8" BONDED WASHER @ 8" O.C. HORIZONTAL SUPPORT POP RIVETS @ 8" O.C. SELF-ADHERING VAPOR BARRIER INSIDE CORNER TRIM POP RIVETS @ 8" O.C. INSIDE CORNER - FLUSH TRIM
INTERIOR @ 8" O.C. EXTERIOR SELF-ADHERING VAPOR BARRIER INSIDE CORNER TRIM FIELD CUT THERMAL BREAK @ 8" O.C. INTERIOR PARTITION F.I.P. INSULATION EXPANSION FASTENER (TO BE LOCATED ON OPPOSITE SIDE OF THERMAL CUT FROM PANEL'S LEADING EDGE) OPTIONAL BUTYL AT WASH DOWN INSIDE CORNER TRIM @ 8" O.C. STRUCTURAL SUPPORT INTERIOR NOTES: 1) ADDITIONAL FASTENERS MAY BE REQUIRED ON EITHER SIDE OF THE FIELD CUT THERMAL BREAK BASED UPON ACTUAL DESIGN LOADS AND THERMAL REQUIREMENTS FIELD FILL WITH INSULATION INSULATE SUPPORTING STEEL ON OF PARTITION (APPROX. 4'-0") FIELD NOTCH PANELS AT GIRT LOCATIONS GIRT CAP TRIM PARTITION TO EXTERIOR WALL
OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) FREEZER DOOR CASING, FASTENERS, SEALANT, & REQUIRED SUPPORT SELF ADHERING VAPOR BARRIER (OPTIONAL - NOT BY KINGSPAN) CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO SEALANT AT PANEL JOINT HEADER CONDITION
SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) SELF ADHERING VAPOR BARRIER (OPTIONAL - NOT BY KINGSPAN) FREEZER DOOR CASING, FASTENERS, SEALANT, & REQUIRED SUPPORT CONTINUOUS BUTYL SEALANT JAMB CONDITION
FIELD ROUT PANELS FOR WOOD SPLINE BASE TRIM WITH POP RIVETS (PRE-INSTALL WEEP HOLES) CONTINUOUS BUTYL SEALANT FIR SPLINE STACK JOINT TRIM WITH POP RIVETS SET FIR SPLINE IN BUTYL SEALANT CONTINUOUS BUTYL SEALANT MARRIED TO SEALANT IN PANEL JOINT CONTINUOUS BUTYL SEALANT AT PANEL JOINT HORIZONTAL SUPPORT 14 GA. GALVANIZED HIDDEN CLIP (1 PER PANEL, PER GIRT) NOTES: 1) SEE DETAIL CS-TL-01-KSV AND CS-TL-02-KSV FOR PROPER TRIM LAP DETAILS 2) CONTACT KINGSPAN TECHNICAL SERVICES FOR PROPER PANEL FASTENING REQUIREMENTS STACK JOINT
GALVANIZED CAP FLASHING ROOF MEMBRANE SYSTEM ATTACHMENT ROOF MEMBRANE BOARD INSULATION AND ROOF UNDERLAYMENT ROOF MEMBRANE SYSTEM ATTACHMENT SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT RAKE TRIM, FASTENERS, SEALANT AND WEATHER TIGHTNESS FIELD CUT THERMAL BREAK SHEETING OR RAKE ANGLE REQUIRED F.I.P. INSULATION OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT CONTINUOUS BUTYL SEALANT AT PANEL JOINT RAKE
GALVANIZED CAP FLASHING ROOF MEMBRANE ROOF MEMBRANE SYSTEM ATTACHMENT CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT INSULATION AND ROOF UNDERLAYMENT FASTENER RAKE TRIM, FASTENERS, SEALANT AND WEATHER TIGHTNESS SEALANT TO MEMBRANE FIELD CUT THERMAL BREAK F.I.P. INSULATION SHEETING OR RAKE ANGLE REQUIRED 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) RAKE W/ MEMBRANE ROOF
F.I.P. INSULATION GALVANIZED CAP FLASHING ROOF MEMBRANE ROOF MEMBRANE SYSTEM ATTACHMENT CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT INSULATION AND ROOF UNDERLAYMENT FASTENER RAKE TRIM, FASTENERS, SEALANT AND WEATHER TIGHTNESS SEALANT TO MEMBRANE FIELD CUT THERMAL BREAK EAVE STRUT OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT CONTINUOUS BUTYL SEALANT AT PANEL JOINT LOW EAVE
SEE CS-CE-04-KSV FOR ADDITIONAL INFO FIELD CUT THERMAL BREAK ATTIC ABOVE CEILING MUST BE VENTILATED F.I.P. INSULATION OUTSIDE CORNER TRIM CEILING SELF ADHERING VAPOR BARRIER WALL INSIDE CORNER TRIM CONTINUOUS BUTYL SEALANT AT PANEL JOINT INTERIOR WALL TO CEILING
#10 X 1 3 8" FASTENER AT EVERY PANEL JOINT BOTH SIDES OF PANEL AA CROSS SECTION (SECTION VIEW ) FIELD CUT THERMAL BREAK CEILING BUTYL SEALANT SUPPORT ANGLE EXPANSION FASTENER COMPRESSIBLE INSULATION A WALL A BUTYL SEALANT #10 X 1 3 8" TEK 1 FASTENER AT EVERY PANEL JOINT (SEE DETAIL ABOVE) WALL TO CEILING INTERSECTION
ATTIC ABOVE CEILING MUST BE VENTILATED INSULATE HANGER RODS AS REQUIRED (NOT BY KINGSPAN) 3 8 " GALVANIZED HANGER ALL-THREAD ROD (ROD SPACING TO BE DETERMINED) TRANSITION FLASHING HEX NUT AND LOCK WASHER 4" X 4" X 14 GA. PLATE WASHER* SELF ADHERING VAPOR BARRIER INTERIOR FACE OF PANEL CEILING CEILING FILL 1 2" GAP BETWEEN PANEL WITH F.I.P. INSULATION HEX NUT AND LOCK WASHER EXTERIOR SIDE OF PANEL MUST BE ON BOTTOM OF CEILING. PANEL CUTLIST MUST MATCH THIS ORIENTATION 1 1 2" X 6" X 14 GA. GALVANIZED CEILING CHANNEL (WHITE POWDER COAT - OPTIONAL) (CAP TRIM - OPTIONAL) #8 GA. SPLAY BRACE WIRE IN FOUR DIRECTIONS 3 8 " ALL-THREAD HANGER ROD FOUR TIGHT TURNS IN 1 1 2" SEISMIC BRACE PLATE * CONTACT KINGSPAN TECHNICAL SERVICES FOR SEISMIC BRACE PLATE QUANTITY AND LOCATION SEISMIC BRACE PLATE CEILING CHANNEL
ATTIC ABOVE CEILING MUST BE VENTILATED 3 8 " GALVANIZED HANGER ALL-THREAD ROD (SPACED NO GREATER THAN 6'-0" O.C.) TRANSITION FLASHING INSULATE HANGER RODS AS REQUIRED (NOT BY KINGSPAN) HEX NUT AND LOCK WASHER 4" X 4" X 14 GA. PLATE WASHER* SELF-ADHERING VAPOR BARRIER INTERIOR FACE OF PANEL CEILING CEILING EXTERIOR SIDE OF PANEL MUST BE ON BOTTOM OF CEILING. PANEL CUTLIST MUST MATCH THIS ORIENTATION 4" X 3" X 3 16" EXTRUDED ALUMINUM CEILING TEE (WHITE POWDER COAT FINISH) FILL 1 2" GAP BETWEEN PANEL WITH F.I.P. INSULATION 3 8 "Ø EYE COUPLER NUT 3 8 "Ø x 1 1 2" BOLT WITH (3) 3 8 " WASHERS AND (1) LOCK-NUT PER BOLT BUTYL SEALANT #8 GA. SPLAY BRACE WIRE IN FOUR DIRECTIONS 3 8 " ALL-THREAD HANGER ROD FOUR TIGHT TURNS IN 1 1 2" SEISMIC BRACE PLATE * CONTACT KINGSPAN TECHNICAL SERVICES FOR SEISMIC BRACE PLATE QUANTITY AND LOCATION SEISMIC BRACE PLATE CEILING TEE
SEISMIC BRACE PLATE (IF REQUIRED) TO BE LOCATED AT EVERY THIRD ROD LOCATION IN LIEU OF PLATE WASHER (SEE DETAIL CS-CE-04-KSV). CONTACT KINGSPAN TECHNICAL SERVICES FOR VERIFICATION. OUTSIDE CORNER TRIM WITH @ 12" OC. (SEALANT OR VAPOR SEAL TAPE AS REQUIRED) SEE DETAIL CS-CE-01-KSV FOR ADD'L INFO. PROJECT ENGINEER OF RECORD MUST VERIFY ROOF IS CAPABLE OF SUPPORTING CEILING SYSTEM LOADS AS WELL AS PROPER CEILING TO ROOF CONNECTION DETAILS LOCATE FIRST HANGER ROD AT LESS THAN 24" FROM FACE OF PANEL ERECTOR MAY PRE-ASSEMBLE HARDWARE ON 3 8" HANGAR RODS- WIRE TIES HOLD WASHERS ABOVE WORKING POINT CEILING TEE HEX NUT ROUND WSHR SPLICE PLATE 4" X 4" X 14 GA. PLATE WASHER WIRE TIE INTERIOR FACE OF PANEL CEILING TEE CEILING TEE SPLICE PLATE W/ (4) 3 8" X 1 1 2" BOLTS, NUTS, AND WASHERS EXTERIOR SIDE OF PANEL MUST BE ON BOTTOM OF CEILING. PANEL CUTLIST MUST MATCH THIS ORIENTATION CEILING TEE ASSEMBLY
PROJECT ENGINEER OF RECORD MUST VERIFY ROOF IS CAPABLE OF SUPPORTING CEILING SYSTEM LOADS AS WELL AS PROPER CEILING TO ROOF CONNECTION DETAILS FIELD NOTCH END OF CHANNEL TO REST ON TOP OF WALL PANEL NUT ROUND WSHR ERECTOR MAY PRE-ASSEMBLE HARDWARE ON 3/8" HANGER RODS- WIRE TIES HOLD WASHERS ABOVE WORKING POINT 4" X 4" X 14 GA. PLATE WASHER WIRE TIE 2'-0" MAX. INTERIOR FACE OF PANEL SPLICE PLATE CEILING CHANNEL 9/16" DIA. HOLES PRE-PUNCHED FOR 3/8" OR ALL-THREAD ROD AT 5'-0" O/C (DO NOT SPACE ALL-THREAD RODS FURTHER THAN 60" APART. THE SPAN FROM WALL TO FIRST ROD, SHALL BE NO GREATER THAN 24".) EXTERIOR SIDE OF PANEL MUST BE ON BOTTOM OF CEILING. PANEL CUTLIST MUST MATCH THIS ORIENTATION CEILING CHANNEL ASSEMBLY
ATTIC ABOVE CEILING MUST BE VENTILATED BUTYL SEALANT INSIDE CORNER TRIM FIELD CUT THERMAL BREAK F.I.P. INSULATION EXPANSION FASTENER CEILING CONTINUOUS BUTYL SEALANT AT "WARM" SIDE PANEL JOINT SUPPORT ANGLE NOTE: CONTACT KINGSPAN TECHNICAL SERVICES FOR ENGINEERING ASSISTANCE CEILING TO WALL - LONGITUDINAL
ATTIC ABOVE CEILING MUST BE VENTILATED 3 8 " GALVANIZED HANGER ALL-THREAD ROD (ROD SPACING TO BE DETERMINED) BUTYL SEALANT INSIDE CORNER TRIM 1 4 " MAX DISTANCE BETWEEN PANEL EDGE AND THREAD ROD FIELD CUT THERMAL BREAK F.I.P. INSULATION EXPANSION FASTENER CEILING CONTINUOUS BUTYL SEALANT AT "WARM" SIDE PANEL JOINT 16 GA. SUPPORT ANGLE HEX NUT AND LOCK WASHER NOTE: CONTACT KINGSPAN TECHNICAL SERVICES FOR ENGINEERING ASSISTANCE CEILING TO WALL - TRANSVERSE
A EXPANSION FASTENERS AS REQUIRED COMPRESSIBLE INSULATION SUPPORT ANGLE (SET IN BUTYL SEALANT) #10 X 1 3 8" TEK 1 FASTENER AT EVERY PANEL JOINT A PARTITION TO ROOF (PERPENDICULAR TO PURLIN) FIELD FILL WITH INSULATION FIELD NOTCH PANELS AT PURLIN LOCATIONS KINGSPAN TO SUPPLY FLAT-STOCK SHEETING TO BE FIELD FORMED FOR PANEL CLOSURES COMPRESSIBLE INSULATION PURLIN AA CROSS SECTION (SECTION VIEW -- TYPICAL AT EACH PURLIN) PARTITION TO ROOF
FILL VOIDS WITH FOAM BLOCK, SET IN BUTYL SEALANT FIELD CUT PANELS AS REQUIRED 1/4"-14 STITCH TEKS AT EACH PURLIN PURLIN CLOSURE TRIM TO BE FIELD CUT TO FIT AT PURLIN FLANGES. USE SILICONE TO SEAL ALL EDGES WHEN COMPLETE. 1/4"-14 STITCH TEKS AT EACH PURLIN SUPPORT ANGLE (SET IN BUTYL SEALANT) ATTACH PURLIN CLOSURES W/ POP RIVETS COMPRESSIBLE INSULATION PARTITION TO ROOF (WITH FOAM BLOCKING) (PERPENDICULAR TO PURLIN) #10 X 1 3 8" TEK 1 FASTENER AT EVERY PANEL JOINT FIELD CUT CONTINUOUS THERMAL BREAK (FREEZER ONLY) COMPRESSIBLE INSULATION EXPANSION FASTENERS AS REQUIRED SUPPORT ANGLE SET IN BUTYL SEALANT PARTITION TO ROOF (PARALLEL TO PURLIN) #10 X 1 3 8" TEK 1 FASTENER AT EVERY PANEL JOINT PARTITION TO ROOF WITH BLOCKING
(2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP MIN. 3" TRIM LAP TRIM END LAP
FIELD NOTCH HEM(S) AS REQUIRED MIN. 3" TRIM LAP (2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP TRIM LAP WITH HEM
(2) BEADS BUTYL SEALANT 8" LONG LAP STRIP NOM. 1 4 " GAP TRIM END LAP WITH LAP STRIP
NOTE: DETAIL SHOWN IS FOR GENERAL USE ONLY (NOT FOR COOLER/FREEZER APPLICATIONS). SEALANT END DAM 2 INTERIOR HEAD TRIM WITH TABS BENT DOWN FIELD NOTCH AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY FIELD MITER AND OVERLAP TRIMS, POP RIVET AS NECESSARY INTERIOR CAP TRIM AT HEAD EXPOSED SEALANT EXTERIOR CAP TRIM AT HEAD 5 EXTERIOR HEAD TRIM W/ FIELD DRILL 3 8" Ø WEEP HOLES INTERIOR JAMB TRIM 1 SILL TRIM WITH TABS BENT UP 6 3 EXTERIOR CAP TRIM AT JAMB FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP 4 EXTERIOR JAMB TRIM FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP EXTERIOR CAP TRIM AT SILL FIELD MITER AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY TRIM INSTALLATION SEQUENCE: 1 INTERIOR JAMB TRIM 2 INTERIOR HEAD TRIM WITH TABS DOWN 3 SILL TRIM WITH TABS UP 4 EXTERIOR JAMB TRIM 5 EXTERIOR HEAD TRIM 6 EXTERIOR SEALANTS AS REQUIRED TRIM LAP AT FRAMED OPENING