PrimeFlow RNA Assay. Simultaneous detection of RNA and protein by flow cytometry

Similar documents
ViewRNA ISH Cell Assays. Visualize RNA with single-molecule sensitivity and single-cell resolution

Page 1 of 2. Product Information Contents: Mouse PrimeFlow RNA Assay (3-plex, see replacement product cat. no )

Cancer inflammation research applications and products

High-throughput automation with the Attune NxT Autosampler: consistent results across all wells and across plates

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

Cell Cycle Phase Determination Kit

CFSE Cell Division Assay Kit

Flow Cytometry - The Essentials

Phagocytosis Assay Kit (IgG PE)

Principles of Multicolor Panel Design BD. BD, the BD Logo and all other trademarks are property of Becton, Dickinson and Company.

Principles of Immunophenotyping

CFSE Cell Division Assay Kit

ViewRNA Cell Plus Assay Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

Methods in virus diagnosis PCR techniques

Technical Review. Real time PCR

Strategies for Assessment of Immunotoxicology in Preclinical Drug Development

Flow Cytometry Immune Activation SOP

Vybrant DyeCycle Violet stain

Application Note. Introduction. Robbie Narang, Zhaoping Liu, Kim Luu IntelliCyt Corporation

Incorporating New, Bright Fluorochromes into Multicolor Panel Design

IsoFluxTM. System. The next generation of CTC Analysis is here

Best practices in panel design to optimize the isolation of cells of interest

Introduction to Flow Cytometry. -- BD FACSCanto II TM. Daisy Kuo Assistant Product Manager BDBiosciences

Flow Cytometry Support Reagents

Page 1 of 2. Product Information Contents: ebioscience BrdU Staining Kit for Flow Cytometry efluor 450

EPIGENTEK. EpiQuik Chromatin Immunoprecipitation Kit. Base Catalog # P-2002 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

DNA/RNA MICROARRAYS NOTE: USE THIS KIT WITHIN 6 MONTHS OF RECEIPT.

EPIGENTEK. EpiQuik Tissue Chromatin Immunoprecipitation Kit. Base Catalog # P-2003 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

THE FREEDOM TO DISCOVER BOND RX FULLY AUTOMATED IHC AND ISH AND EMERGING TESTS RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.

No-wash, no-lyse detection of phagocytic cells via a phrodo BioParticles functional assay in human whole blood on the

DEPArray Technology. Sorting and Recovery of Rare Cells

Contents... vii. List of Figures... xii. List of Tables... xiv. Abbreviatons... xv. Summary... xvii. 1. Introduction In vitro evolution...

Page 1 of 2. Product Information Contents: ebioscience BrdU Staining Kit for Flow Cytometry APC

Page 1 of 2. Product Information Contents: ebioscience BrdU Staining Kit for Flow Cytometry FITC

ab CFSE Fluorescent Cell Labeling Kit

Gene expression profiling of a single cell using laser capture microdissection and OpenArray technology

11/19/2013. Janine Zankl FACS Core Facility 13. November Cellular Parameters. Cellular Parameters. Monocytes. Granulocytes.

The measurement of telomere length was performed by the same method as in the previous study (11).

Principles of flow cytometry: overview of flow cytometry and its uses for cell analysis and sorting. Shoreline Community College BIOL 288

Vybrant DyeCycle Green and Orange Stains

Modeling Cardiomyocyte Differentiation:

AMREP FLOW CYTOMETRY CORE FACILITY. Flow Cytometry Data Analysis Workshop Friday 24 th October

APPLICATION NOTE. MagMAX mirvana Total RNA Isolation Kit TaqMan Advanced mirna Assays

High-dimensional flow-cytometric analysis of human B-cell populations

Flow Cytometry SOP: Monocytes from Frozen Cells

EdU Click FC ROTI kit for Flow Cytometry

ab CFSE Fluorescent Cell Labeling Kit

E. coli Phagocytosis Assay Kit

Introduction to Flow Cytometry. -- BD FACSCanto II TM. Daisy Kuo Application Specialist BDBiosciences

Flow cytometry analysis of transcription factor expression during differentiation of hpsc-derived cardiomyocytes

Flowcytometry-based purity analysis of peritoneal macrophage culture.

Advanced Therapeutic Antibody Discovery with Multiplexed Screening

NovoCyte Flow Cytometer

EdU Flow Cytometry Kit. User Manual

Supplementary Figure 1. Characterization of the POP2 transcriptional and post-transcriptional regulatory elements. (A) POP2 nucleotide sequence

Expression Array System

TARGETS Anti-Biotin Anti-Streptavidin Anti-FITC Anti-Phycoerythrin Anti-Mouse IgG Anti-Rabbit IgG (H+L) Anti-Human IgG (H+L)

Protein and transcriptome quantitation using BD AbSeq Antibody-Oligonucleotide

Flow Cytometry SOP: 14 color flow for immune activation, senescence, and exhaustion

Utility of Branched DNA Hybridization Methodology for the Quantitation of Oligonucleotides

Gene Regulation Solutions. Microarrays and Next-Generation Sequencing

Detection of bacterial aggregation by flow cytometry

CytoPainter Nucleolar Staining Kit - Green Fluorescence

USER GUIDE. Introduction. Catalog No. C10423, C10723

CRC Flow Cytometry Core Facility Knut och Alice Wallenbergs Stiftelse

Xfect Protein Transfection Reagent

TaqMan Advanced mirna Assays

Assay Name: HPC proliferation measurement using Ki-67 cellular marker

Your Research, Revolutionized

Roche Molecular Biochemicals Technical Note No. LC 10/2000

Boundary-breaking acoustic focusing cytometry

Supplementary Figure 1: Overexpression of EBV-encoded proteins Western blot analysis of the expression levels of EBV-encoded latency III proteins in

Chromatin immunoprecipitation: five steps to great results

Simultaneous detection of mirna and mrna on TaqMan Array Cards using the TaqMan Advanced mirna workflow

Fluorescent In Situ Hybridization (FISH) Assay

Index. Index 425. Bacteria flow cytometry, general considerations, 33, 34 Gram-negative versus Grampositive

DURACLONE IM ACCELERATE YOUR PACE IN IMMUNE SYSTEM RESEARCH. For Reseach Use Only - Not for use in Diagnostic procedures

User Manual. QuantiGene ViewRNA mirna ISH Cell Assay. Format: 96-well optical-bottom plate. P/N Rev.A

Supplementary Figure 1: (a) 3D illustration of the mobile phone microscopy attachment, containing a 3D movable sample holder (red piece for z

DEFY THE LAW OF AVERAGES. Single-Cell Targeted Gene Expression Analysis

ncounter Vantage 3D RNA:Protein Immune Cell Signaling Panel for Cell Suspensions

A Supersandwich Fluorescence in Situ Hybridization (SFISH) Strategy. for Highly Sensitive and Selective mrna Imaging in Tumor Cells

MagniSort Mouse Hematopoietic Lineage Depletion Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

Application Note. Assay Portability on the BD FACSVerse System. Summary. Maria Jaimes, Yibing Wang, Catherine McIntyre, and Dev Mittar

Data Sheet CD137/NF-κB Reporter - HEK293 Recombinant Cell Line Catalog # 79289

Reagent Titration for the ICS Assay

Propidium Iodide. Catalog Number: Structure: Molecular Formula: C 27H 34I 2N 4. Molecular Weight: CAS #

Zenon Goat IgG Labeling Kits

A comparison of protein detection and quantification techniques

P HENIX. PHENIX PCR Enzyme Guide Tools For Life Science Discovery RESEARCH PRODUCTS

Bioinformatics: Microarray Technology. Assc.Prof. Chuchart Areejitranusorn AMS. KKU.

Cellometer Vision CBA

SuperScript IV Reverse Transcriptase as a better alternative to AMV-based enzymes

Cytomics in Action: Cytokine Network Cytometry

FirePlex mirna Assay. Multiplex microrna profiling from low sample inputs

ELISPOT and FLUOROSPOT kits

What you need to know before designing a panel

American Society of Cytopathology Core Curriculum in Molecular Biology

USER GUIDE. Introduction. Catalog No. C10730, C10731

Transcription:

PrimeFlow RNA Assay Simultaneous detection of RNA and protein by flow cytometry

Detect RNA and protein simultaneously by flow cytometry With the novel Invitrogen PrimeFlow RNA Assay, scientists can now reveal the dynamics of RNA and protein expression simultaneously within millions of single cells. This assay employs a proprietary FISH and bdna amplification technique for simultaneous detection of up to four RNA transcripts labeled with Invitrogen Alexa Fluor 488, Alexa Fluor 568, Alexa Fluor 647, and Alexa Fluor 750 dyes in a single cell, using a standard flow cytometer. RNA detection may be combined with intracellular and cell-surface antibody staining to elevate the understanding of single-cell dynamics to a new dimension. Key features: See gene expression heterogeneity at the single-cell level Compare RNA and protein kinetics in the same cell Detect noncoding RNA in cellular subsets Evaluate viral RNA in infected cells Analyze mrna expression levels when antibody selection is limited Analyze up to 4 RNA transcripts simultaneously Assay technology Fluorescence in situ hybridization (FISH) is a powerful technique that allows specific localization of ribonucleic acid targets in fixed cells. The basic premise of the application relies on detecting nucleic acids through sequential hybridization of nucleic acid probes that provide gene expression information at the single-cell level. Traditional FISH techniques are generally limited by high background and low sensitivity due to nonspecific binding and inefficient signal amplification. Detect microrna (mirna) by flow cytometry 2

Principle of the PrimeFlow RNA Assay The PrimeFlow RNA Assay incorporates a proprietary oligonucleotide probe set design and branched DNA (bdna) signal amplification technology to analyze RNA transcripts by flow cytometry. bdna technology provides a unique approach to RNA detection and signal amplification by amplifying the reporter signal rather than the target sequence (e.g., PCR) to help enable more consistent results than those obtained using PCR-based assays. In the PrimeFlow RNA Assay, target-specific probe sets contain 20 to 40 oligonucleotide pairs that hybridize to the target RNA transcript (Figure 1). Signal amplification is achieved through specific hybridization of adjacent oligonucleotide pairs to bdna structures, formed by preamplifiers, amplifiers, and fluorescently labeled probes (Figure 2), resulting in excellent specificity, low background, Sample Sample Sample Target Target Target and high signal-to-noise ratios. Preparation Preparation Hybridization Sample Preparation Sample Target Hybridization Target Sample SamplePreparation Hybridization Target Target Gene-specific Hybridization Label Preparation Hybridization Left Left oligo Oligo Figure 3A Right Oligo oligo Labeled Probe probe Amplifier Preamplifier Gene-specific Label Gene-specific Label PreAmplifier Fluorescent Label PreAmplifier PreAmplifier Detection Fluorescent Label Sample preparation Target hybridization Fluorescent Label Extenders (LE) Extenders Extenders (LE) (LE) Amplification Signal amplification Detection Probe Probe Probe Gene-specific Label Gene-specific Label PreAmplifier Fluorescent Label PreAmplifier Fluorescent Label Extenders Gene-specific (LE) Extenders Label Label Add Label Probes to (LE) PreAmplifier Preamplifier Probe Fluorescent Add Fluorescent Label Fluorescently Add Probes Label Label Probes to labeled to probes Extenders Extenders label extenders (LE) (LE) (LE) cells Probe cells Probe Add cellslabeled probes to cells Gene-specific Gene-specific Gene-specific Add Label Probes to Add Label Probes to Blocking Probes (BL) Amplifier Blocking Blocking Probes Probes (BL) (BL) Amplifier Amplifier cells Add Add Label Label Probes cells Probes to to (Antibody staining Gene-specific Gene-specific cells cells (Antibody (Antibody staining staining optional) Blocking Gene-specific Probes (BL) Amplifier Blocking Probes (BL) Amplifier optional) optional) Amplifier Hybridization of (Antibody staining Blocking Blocking Probes Probes (BL) (BL) Amplifier Hybridization Amplifier Hybridization of of (Antibody staining Incubate cells with Pre-Amplifier and Label optional) proteins Fix and Permeabilize Incubate Incubate cells with cells with Pre-Amplifier Pre-Amplifier and and (Antibody (Antibody with staining optional) Fix antibody Fix and staining and Permeabilize Incubate cells with Gene genespecific probe sets preamplifier Hybridization Amplifier DNA and DNA of Specific Hybridize with Permeabilize Amplifier DNA suspension cells Gene Specific Gene Specific Hybridization Amplifier of (optional) optional) optional) suspension suspension cells cells Incubate probe sets (Type 1, 4, and 6) probe cells with Incubate probe sets sets cells with Pre-Amplifier Fix and Permeabilize Hybridization (Type amplifier and Pre-Amplifier 1, (Type of 4, DNA and of 1, 4, 6) and and 6) Fix and permeabilize Fix cells and in Permeabilize Gene (Type 1, 4 or 6) Incubate Specific (Type cells Gene 1, (Type with 4 or Specific 1, 6) 4 or 6) Amplifier and DNA Fix and cells Incubate cells with Amplifier DNA suspension Pre-Amplifier and Fix and Permeabilize suspension cellsprobe process cells using Gene Gene sets Specific Specific probe sets (Type Amplifier Amplifier 1, 4, and DNA 6) (Type DNA 1, 4, and 6) process process cells using cells using Label suspension intracellular suspension cells proteins cells (Type a standard Flow probe 1, 4 sets or 6) Process cells using probe sets (Type 1, 4 or 6) (Type (Type 1, 4, 1, and 4, and 6) 6) a standard a standard Flow Flow with antibodies (optional) process cells Cytometer Instrument (Type 1, 4 or 6) Cytometer usinga flow cytometer (Type 1, 4 or 6) process Cytometer Instrument cells Instrument using a standard process process cells Flow cells a using standard using Flow Gene 1 Cytometer Gene 1 Gene 1 a standard a standard Instrument Flow Cytometer Flow Instrument Cytometer Cytometer Instrument Instrument Gene 2 Gene 2 Gene 1 Gene 2 Gene 1 Gene Gene 2 Gene 1 1 Gene 2 Gene Gene 2 2 Suspension cells Suspension Suspension cells cells with RNA fixed with RNA with fixed RNA fixed Suspension cells Suspension cells Suspension with Suspension RNA cells fixed with fixed RNA Suspension cells with cells RNA fixed with with RNA RNA fixed fixed Development of the PrimeFlow RNA Assay is based upon proven and well-published ViewRNA technology designed for microscopic analysis of RNA in cells and tissues. The assay combines paired oligonucleotide probe design with bdna signal amplification to robustly detect up to four RNA transcripts at the single-cell level using a standard flow cytometer. Pre-Amplifi RNA Signal Signal Signal Hybridization Figure 1. PrimeFlow Detection Amplification Amplification RNA Assay bdna. Detection Detection Signal Amplification Signal Detection Amplification Signal Signal Detection Amplification CD8 mrna CD8 PE-Cyanine7 Figure 2. The PrimeFlow RNA Assay workflow. The assay workflow contains several steps: antibody staining; fixation and permeabilization, including intracellular staining, if desired; followed by target hybridization with a target-specific probe set containing 20 40 oligonucleotide pairs. 3

Compare RNA and protein kinetics in the same cell In response to external stimuli, differential regulation of RNA transcription leads to changes in protein level. However, the levels of RNA and protein products of specific genes may vary at any given point in time. Using current methods such as qpcr or microarrays, researchers must choose between measuring mrna or protein because they cannot be measured simultaneously due to the limitations of prevailing techniques. Invitrogen PrimeFlow technology can reveal the unique kinetics of mrna and protein in different cell subsets, and identify expression differences as they change over time in response to the stimulus. Correlation and kinetics of IFNγ and TNFα transcription and translation Aims Intracellular staining and flow cytometric analysis of lymphocytes is commonly used to assess cytokine production at the single-cell level in heterogeneous samples. Here, the PrimeFlow RNA Assay is used in combination with intracellular antibody staining to study the kinetics of the transcription and translation of IFNγ and TNFα in lymphocyte subsets. Results IFNγ mrna was upregulated in CD8 + and CD8 lymphocytes within 1 hour after stimulation, while protein levels were not detected until 2 hours. Both IFNγ mrna and protein were maintained for the next 3 4 hours (Figures 3A and 3C). In contrast, TNFα mrna and protein were both upregulated within 1 hour after stimulation and expression was maintained in CD8 + cells, while expression in CD8 cells peaked between 1 2 hours and then decreased over the next 4 hours, with the decrease in mrna preceding the decrease in protein (Figures 3B and 3D). Conclusions Using the PrimeFlow RNA Assay, we find that induction of IFNγ and TNFα mrna and protein exhibit unique kinetics, and that TNFα protein and mrna are differentially regulated in CD8 + and CD8 lymphocytes. This assay enables the study of gene expression at the single-cell level in heterogeneous samples without the need for sorting specific subsets, as well as the ability to compare and contrast the kinetics of mrna and protein induction. A B 100 IFNγ mrna and protein kinetics 100 TNFα mrna and protein kinetics Percent of positive cells 75 50 25 0 0 1 2 3 4 5 Hours post-stimulation CD8 + protein CD8 + mrna CD8 - protein CD8 - mrna Percent of positive cells 75 50 25 0 0 1 2 3 4 5 Hours post-stimulation CD8 + protein CD8 + mrna CD8 - protein CD8 - mrna Figure 3. Kinetics of IFNγ and TNFα transcription and translation measured by the PrimeFlow RNA Assay. Normal human peripheral blood mononuclear cells were stimulated with the Invitrogen ebioscience Cell Stimulation Cocktail (plus protein transport inhibitors) (Cat. No. 00-4975) for 0 5 hours. Using the PrimeFlow RNA Assay, cells were fixed, permeabilized, and intracellularly stained with antibodies for CD8, IFNγ, and TNFα. Next, cells underwent a series of hybridization steps to label mrna for IFNγ and TNFα. Viable CD8 + and CD8 cells in the lymphocyte gate were used for analysis. A and C illustrate the kinetics of IFNγ, and B and D illustrate the kinetics of TNFα. 4

C Human IFNγ induction and correlation between mrna and protein D Human TNFα induction and correlation between mrna and protein CD8 + subset CD8 subset CD8 + subset CD8 subset 0 hr 1 hr 2 hr 3 hr 4 hr 5 hr 5

Observe gene expression heterogeneity at the single-cell level Cellular heterogeneity is present in any biological sample, from low- to high-protein levels in cell subsets or gene expression differences from cell to cell. Paradoxically, most of our understanding of gene expression is based upon bulk population averages. This analysis, although informative, often leads to conclusions that assume ensemble averages reflect the dominant biological mechanism operating within an entire population. Using such measurements and assumptions can mask the presence of rare or small subpopulations of cells or bimodal cellular behaviors, and ignores essential cellto-cell differences. To fully understand whether cellular heterogeneity contributes to biological function or contains relevant information, a single-cell approach must be applied. The PrimeFlow RNA Assay reveals differential responses following stimulation and, thus, the hidden story that is otherwise masked by using RT-qPCR to analyze the entire population. Revealing a hidden story beneath bulk masking Aims mrna is commonly assessed by quantitative RT-PCR (RT-qPCR) where cells are isolated after stimulation so that total RNA can be extracted and then undergo RT-PCR reactions. This results in amplified bulk measurements that mask the differences in gene expression that occur at the single-cell level. In this example, PrimeFlow RNA data are compared to RT-qPCR. Results The same cell populations in Figure 3 (pages 4 and 5) were analyzed by RT-qPCR. Using RT-qPCR, it appears that IFNγ and TNFα are initially induced at similar levels and IFNγ plateaus, while TNFα declines slowly (Figures 4A and 4B). However, with the PrimeFlow RNA assay, it is observed that TNFα mrna is rapidly and highly induced at 1 hour, dramatically declines between 1 2 hours, and continues to decline more slowly 3 5 hours after stimulation. In contrast, IFNγ is maintained throughout the time course. As shown in Figure 3, PrimeFlow RNA data can be further analyzed into CD8 + or CD8 cell subsets, which reveal additional sample heterogeneity that RT-qPCR cannot achieve from a single sample. The PrimeFlow RNA Assay shows that the percentage of cells expressing IFNγ is less than the percentage of cells expressing TNFα. Conclusions Examination of stimulated cells over time using current RT-qPCR technology shows similar kinetics as with PrimeFlow RNA technology. However, the PrimeFlow RNA Assay uncovers the finer details of the kinetics at a singlecell level and allows users to study multiple parameters within the same sample, thereby eliminating the bulk averages previously masking cellular heterogeneity. 6

A Cytokine mrna expression measured by RT-qPCR B Percentage of cells expressing cytokine mrna measured by PrimeFlow RNA Assay 8 80 log 2 fold change 7 6 5 4 3 2 1 IFNγ % positive cells 70 60 50 40 30 20 IFNγ 0 TNFα 10 TNFα 0 1 2 3 4 5 0 0 1 2 3 4 5 Hours post-stimulation Hours post-stimulation Figure 4. IFNγ and TNFα mrna measured by RT-qPCR and PrimeFlow RNA assays. (A) Normal human peripheral blood mononuclear cells were stimulated with the ebioscience Cell Stimulation Cocktail (plus protein transport inhibitors) (Cat. No. 00-4975) for 0 5 hours. (B) RNA was isolated and was analyzed by RT-qPCR. Using the PrimeFlow RNA Assay, the cells were fixed, permeabilized, and intracellularly stained with antibodies for CD8, IFNγ, and TNFα. Next, cells underwent a series of hybridization steps to label mrna for IFNγ and TNFα. Viable cells in the lymphocyte gate were analyzed for percentage of cytokine-producing cells. 7

Analyze mrna expression levels when antibody is limited Flow cytometry, with its ability to look at millions of cells and multiplexing capabilities and its straightforward workflow to detect both cell surface and intracellular proteins with single-cell resolution is the gold standard for the study of heterogeneous cell populations. However, flow cytometry historically has been constrained by the availability and adequacy of antibodies. Noncoding RNA, viral transcripts, unique model organisms and/or targets, or markers for which antibody development is troublesome have not benefited from the power of flow cytometry and have required numerous disconnected experiments to analyze their impact on cell subsets. The PrimeFlow RNA Assay can detect target-specific RNA for which available flow cytometry antibodies are nonexistent. IL-23R mrna expression by flow cytometry Aims IL-23R is expressed by Th17 cells, a subset of activated CD4 + T cells that play a key role in defense of mucosal barriers against extracellular bacteria and fungi. While Th17 cell differentiation is controlled by TGFβ, IL-6, and IL-1, IL-23 is crucial for their survival and function and has been implicated in many autoimmune diseases. The study of IL- 23R is impaired by the lack of antibodies with appropriate sensitivity; most studies involving IL-23R in Th17 cells examine gene expression at the population level. The data obtained are unquestionably informative; however, they mask the actual expression heterogeneity. Here, the PrimeFlow RNA Assay is used in combination with antibody staining to interrogate the heterogeneity of IL-23R mrna expression in polarized Th17 cell subsets. Results Normal human peripheral blood cells were cultured under Th17-polarizing conditions for 3 days and then restimulated. Under these conditions, only a subset of IL- 17A + or IL-17AF + cells expressed low levels of IL-23R mrna (Figure 5). Conclusions A strength of the PrimeFlow RNA Assay is its ability to detect most mrnas in individual cells without being limited by antibody availability. This applies to targets for which antibody development is difficult (e.g., IL-23R, GPCRs), unique model organisms (e.g., canine, fish), or esoteric markers for which no commercial antibodies are available. The PrimeFlow RNA Assay can also be used to detect non protein-coding RNA targets (lncrna, viral transcripts) against which antibodies cannot be made. 8

No probe IL-23R mrna Fixable Viability Dye efluor 506 IL-17A PE-Cyanine 7 IL-17AF efluor 450 Forward scatter CD4 PE-eFluor 610 CD4 PE-eFluor 610 No probe No probe IL-23R mrna IL-23R mrna CD4 PE-eFluor 610 IL-17A PE-Cyanine7 IL-17AF efluor 450 CD4 PE-eFluor 610 Mouse lgg1 PE-Cyanine7 Mouse lgg1 efluor 450 Figure 5. IL-23R mrna expression in Th17 cell subsets by the PrimeFlow RNA Assay. Normal human peripheral blood cells were cultured under Th17-polarizing conditions for 3 days, then restimulated with ebioscience Cell Stimulation Cocktail (plus protein transport inhibitors) (Cat. No. 00-4975) for 5 hours. Cells were labeled with Invitrogen ebioscience Fixable Viablity Dye efluor 506 (Cat. No. 65-0866), fixed and permeabilized using the PrimeFlow RNA Assay buffers, then intracellularly stained with Anti-CD4 PE-eFluor 610, Anti-IL-17A PE-Cyanine7, and Anti-IL-17AF efluor 450. Next, cells underwent a series of hybridization steps to label mrna for IL-23R. 9

Evaluate viral RNA in infected cells Coinfection by multiple virus particles can lead to increased pathology and morbidity, as is the case of human immunodeficiency virus (HIV) and hepatitis C virus (HCV) coinfections seen in older AIDS patients or superinfection with hepatitis B and HCV. Understanding the lack of virus interference in these cases, on a per-cell basis, may have implications in the future design and delivery of vaccines. To date, there are no robust methods to track and study individual coinfected cells. The PrimeFlow RNA Assay can be used for the direct detection of multiple viral transcripts within a single cell by flow cytometry, thus facilitating the detailed study of coinfected populations of cells. Detection of hepatitis C viral RNA in coinfected human hepatocytes Method Hepatocytes were coinfected with two strains of HCV, JFH1-wild type (WT) and JFH1-codon altered (CA). Probes were designed to differentiate the two strains of HCV to study dominance relationships in coinfected cells. These probes were then applied using the PrimeFlow RNA Assay and Invitrogen ViewRNA Assay. Results The PrimeFlow RNA Assay clearly defined JFH1-WT singlepositive, JFH1-CA single-positive, and double-positive populations (Figure 6). The orthogonal ViewRNA Assay was used to verify that the probe design was highly specific for the indicated strains of HCV (Figure 7). Conclusions The PrimeFlow RNA Assay is the first commercial assay that can study individual cells that have been coinfected. * Data courtesy of Nicholas J. van Buuren and Karla Kirkegaard (PI), Stanford University School of Medicine. Data obtained using version 1 of the QuantiGene FlowRNA Assay. The QuantiGene FlowRNA Assay and PrimeFlow RNA Assay have the same RNA hybridization and branched DNA amplification protocol. 10

JFH1-WT vrna JFH1-WT strain WT 75% non-infected 21% coinfected 0% strain CA 0% JFH1-CA vrna Alexa Fluor 750 JFH1-WT vrna JFH1-CA strain WT 0% non-infected 18% coinfected 0% JFH1-CA vrna Alexa Fluor 750 strain CA 79% JFH1-WT vrna Mixed JFH1-CA vrna Alexa Fluor 750 JFH1-WT vrna Cotransfected coinfected 1% strain WT 42% strain WT 1% strain CA 36% non-infected 18% non-infected 18% coinfected 71% strain CA 5% JFH1-CA vrna Alexa Fluor 750 Figure 6. Coinfected viral RNA proof of principle.* Hepatocytes were infected with JFH1-WT strain (top left) or JFH1-CA (top right). Hepatocytes from these two single infections were mixed post-infection (bottom left), or hepatocytes were coinfected with JFH1-WT and JFH1-CA (bottom right). Using the Invitrogen QuantiGene FlowRNA Assay, hepatocytes were analyzed for strain-specific viral RNA. DAPI Type 1 Type 6 Merge JFH1-CA JFH1-WT Figure 7. Visualization of specificity.* Hepatocytes infected with JFH1-WT (top row) or JFH1-CA (bottom row) were analyzed using the ViewRNA Assay and the same target probe sets used in the PrimeFlow RNA Assay. 11

Make new discoveries and challenge current conventions Most diseases, such as cancer, are complex and highly heterogeneous. With its ability to look at millions of single cells in a high-throughput manner, flow cytometry is one of the most prevalent technologies used to study complex disease. However, there is still a great need to improve therapeutic targeting and efficacy through improved understanding of disease states. RNA detection, teamed together with intracellular and cell-surface antibody staining, elevates the understanding of single-cell dynamics to a new dimension, allowing researchers to further unmask these complex diseases with a unique tool. Cell cycle regulation Aims Proliferation and cell cycle progression are tightly controlled biological processes mediated by cyclins and cyclin inhibitors. Each phase of the cell cycle can be characterized by the expression of specific cyclins; however, cells must be synchronized in vitro in order to assay the kinetics of cyclin expression, using bulk sample methods currently available. Here, the PrimeFlow RNA Assay is applied to the detection of cyclins in unsynchronized U937 cells, untreated or treated with nocodazole, allowing for analysis of cells in different stages of the cell cycle. Results U937 cells showed upregulation of cyclin A and cyclin B mrna, but not of cyclin E mrna, in treated cells when compared to untreated cells. Expression of the positive control gene (GAPDH) was minimally affected by nocodazole treatment. Therefore, the mechanics of nocodazole were confirmed with the PrimeFlow RNA Assay (Figure 8). Conclusions The PrimeFlow RNA Assay answers previously unanswerable questions in numerous fields, from immunology to cancer research to cell biology. Life happens at a single-cell level but also as a collection of millions of cells working together in complex environments. The assay is the first and only tool that combines single-cell resolution with the acquisition of millions of cells to study both RNA and protein expression, allowing researchers to create new discoveries and challenge current conventions. 12

Control DapB Control Cyclin/GAPDH probe Treated DapB Treated Cyclin/GAPDH probe Cyclin expression cycle Cyclin E Cyclin A Cyclin B Count Count Concentration Cyclin D x Cyclin A2 mrna Cyclin B1 mrna G1 S G2 Mitosis Count Count Nocodazole Cyclin E1 mrna GAPDH mrna Figure 8. Cyclin detection in unsynchronized U937 cells. U937 human monocytic cells were untreated (black and green histograms) or treated with nocodazole for 16 hours (purple and red histograms). Nocodazole disrupts microtubules, leading to cell cycle arrest at the G 2 /M checkpoint. After stimulation, cells were analyzed using the PrimeFlow RNA target probe sets for cyclin A2, cyclin B1, or cyclin E1. The target probe set for GAPDH was used as a positive control. 13

Notes: 14

15

Ordering information Required products for the PrimeFlow RNA Assay mrna/lncrna detection PrimeFlow RNA Assay Kit contains all the reagent needed to conduct the assay Invitrogen PrimeFlow Probe Sets target-specific probes (labeled with Alexa Fluor 488, Alexa Fluor 568,, and Alexa Fluor 750 dyes); see the PrimeFlow RNA Probe Set catalog mirna detection PrimeFlow RNA Assay Kit contains all the reagent needed to conduct the assay PrimeFlow Probe Sets target-specific probes; Due to the short length of mirna, the signal generated per molecule of mirna is expected to be significantly lower than mrna. Therefore, it is highly recommended to use, or Alexa Fluor 568, for detection of mirna for maximal sensitivity. Invitrogen PrimeFlow microrna Pretreatment Buffer improves the retention of some small RNA targets, resulting in higher signal and better sensitivity Product Size Cat. No. 40 tests 88-18005-204 PrimeFlow RNA Assay Kit 100 tests 88-18005-210 PrimeFlow microrna Pretreatment Buffer 100 tests 88-18006 Optional kits, each sold separately Positive control use positive control probe sets in every experiment to ensure proper assay performance: RPL13a for human leukocytes and β-actin (ACTB) for mouse tissues; for specific cell types and other recommended genes, refer to Appendix 5 in the product manual of the PrimeFlow RNA Assay Kit Negative control such as samples with the targetspecific probe omitted, or samples labeled with a probe against a target not expressed in the cells of interest (e.g., dapb, a bacterial gene); highly recommended Temperature validation kit the Invitrogen ViewRNA Temperature Validation Kit uses a calibrated thermometer to assess the accuracy of the temperature of the incubator used in the assay Incubator capable of maintaining temperature at 40 ± 1 C Metal heat block for 1.5 ml microcentrifuge tube placed inside the validated incubator Antibodies for protein detection see thermofisher.com/antibody Product Size Cat. No. ViewRNA Temperature Validation Kit 1 QV0523 Horizontal Air Flow Oven, 120 V, 1.6 cubic feet 1 QS0704 or QS0712 Metal heat block 1 13-687-210 PrimeFlow Probe Sets PrimeFlow Probe Sets consist of target-specific oligonucleotide pairs, preamplifier oligonucleotide, and amplifier oligonucleotide. Four types of fluorescently labeled probe sets are currently available to enable detection of RNA: (type 1 probe sets), Alexa Fluor 488 (type 4 probe sets), Alexa Fluor 750 (type 6 probe sets) and Alexa Fluor 568 (type 10 probe sets). Go to thermofisher.com/primeflow to view a complete listing of over 8,200 synthesized probe sets. Probe sets Product Size Cat. No. PrimeFlow Probe Sets, mrna/lncrna 40 tests PF-204 100 tests PF-210 PrimeFlow Probe Sets, mirna 40 tests PM-204 100 tests PM-210 Custom probes By request, PrimeFlow Probe Sets can be designed and synthesized at no additional cost. Please provide the following information when ordering: accession number (including version or GI number) or RNA sequence for the target of interest, species, gene name or symbol, PrimeFlow Probe Set type, and any special design requirements. Assay details Specification Description Single-cell suspensions, including human whole blood and peripheral blood mononuclear cells (PBMC), mouse dissociated tissues, and cell Sample type lines. See Appendix 5 in the product manual for a complete list of validated cell types. Species Mammalian Multiplex level Up to four RNA targets simultaneously 1.5 ml microcentrifuge tube or 96-well v-bottom plate. See Appendix 7 in Assay format the product manual for the protocol for using 96-well plates. Flow cytometer equiped with: Blue (488 nm), yellow-green (561 nm), and red (633 640 nm) lasers Instrumentation Filter sets for FITC (bandpass 530/30), PE efluor 610 (PE Texas Red) (bandpass 610/20), APC (bandpass 660/20), and APC efluor 780 (APC-Cyanine7) (bandpass 780/60) Find out more at thermofisher.com/primeflow For Research Use Only. Not for use in diagnostic procedures. 2017 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. COL03964 0917