Rosemount 1152 Alphaline Nuclear Pressure Transmitter

Similar documents
Rosemount 1154 Alphaline Nuclear Pressure Transmitter

Rosemount 1153 Series D Alphaline Nuclear Pressure Transmitter

Model 1159 Remote Diaphragm Seals

Rosemount 3154N Nuclear Qualified Pressure Transmitter

Rosemount 3155N Nuclear Qualified Pressure Transmitter

Rosemount 3154N Nuclear Qualified Pressure Transmitter

TEK-B AR 3120B. Smart Gauge Pressure Transmitter. PRESSURE. Technology Solutions

TEK-B AR 3800E. Multivariable Pressure Transmitter. PRESSURE. Technology Solutions

Rosemount 405 Compact Primary Element

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

APT3200 SMART PRESSURE TRANSMITTER. Range and Sensor Limits Refer to Table 1. Isolation Input/output isolated to 500Vrms (707 Vdc)

GUC LNG Facility Phase IIB Expansion 6/20/14 INSTRUMENTATION SPECIFICATION. A. This Section includes instrumentation for process piping systems.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

Weed Instrument Model 601 and 611 Series Platinum RTDs are Direct Immersion Temperature Sensors. Weed Instrument

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Rosemount 405 Compact Orifice Primary Element

Type Type 2000 Transducers. I/P & E/P Transducers

Pressure Transmitter STK136,STK136Q

Miniature I/P, E/P Transducer

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

Weed Instrument Model 602, 612 and 615 Series Platinum RTDs are Spring Loaded Temperature. Weed Instrument

SmartLine. MVX700 SmartLine Multivariable Meter Body Specification 34-ST Technical Information. Introduction

SBX 1000 In Situ Oxygen Transmitter

PRODUCT INFORMATION. Model 140MX Flowmeter Functional Overview. PI 14-1 Rev: 1 March 2002

VLM10 In-line Vortex Mass Flow Meter

Model 140MX Flowmeter Functional Overview

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Rosemount 3095FT MultiVariable Flow Data Logger THE PROVEN LEADER IN MULTIVARIABLE MEASUREMENT:

Rosemount 3051S Series of Instrumentation Scalable Pressure, Flow, and Level Solutions

Coriolis Mass Flow Meter

M7100 Pressure Transducer

Spare List SPL/266XXX-EN Rev. B. Models 266XXX spare parts list. 2600T Series Pressure Transmitters Engineered solutions for all applications

Pressure transducers DMU 02 Vario (flush)

F-2200 Series Steam Meter

M7100 Pressure Transducer

RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits

SECTION LOW-VOLTAGE TRANSFORMERS

RHM60. Coriolis Mass Flow Meter with Uncompromising Performance. Features. Applications. Benefits

IOMaster FPD510 Compact integral orifice flowmeter. Low-cost measurement of small flowrates

HT829 Humidity Transmitter HT839 Humidity and Temperature Transmitter Installation and Operating Instructions

Pressure & Differential Pressure Transmitter

ST3000 Series 900 Smart Transmitter Remote-sealed type of Differential Pressure Transmitters

World Top Class FCX-A

MSP300 Pressure Transducer

Technical Specifications and General Guidelines for Mass Flow Meters at Petroleum Oil Installations. Note:

Monolithic Isolation Fittings

Data Sheet Duragauge Pressure Gauge

Micro Motion TA-Series Flow and Density Meters

STANDARD RANGES (ALL INTERMEDIATE RANGES ARE STANDARD) Range (psi) Range (Bar) Gage/Compound 0 to to to to to to t

Paine Series Pressure Transmitter

SECTION Inline ULTRASONIC FLOW METERS

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

Rosemount Annubar Flowmeter Series. The Value of Innovation, Realized

Rosemount Differential Pressure Level Solutions. Keeping You a Step Ahead

World Top Class FCX-A

D5100 Industrial Differential Pressure Transducer

Single-Use Sensors. TruFluor and TruTorr Excellence in bio-processing measurement

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate

Fractional Pressure Gauge Heavy Duty Pressure Gauge Homogenizer Pressure Gauge High Accuracy Pressure Transmitter Homogenizer Pressure Transmitter

DS-4018 English Rev. FA. ProPlate Flowmeter Mass ProPlate Flowmeter Model 1195 Integral Orifice

Presented By. NicolScales.com Contact Us

ElectroStop. Monolithic Isolation Joints INNOVATIVE ENGINEERING FOR CORROSION PROTECTION

ENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument

SPECIFICATIONS - DETAILED PROVISIONS Section Chlorination System (On-site Sodium Hypochlorite Generation System) C O N T E N T S

SECTION PRESSURE AND DIFFERENTIAL PRESSURE GAUGES

MSP300 Pressure Transducer

SECTION METAL-ENCLOSED BUS MEDIUM VOLTAGE

1511 Series. Consolidated * Valves. Safety Valve

SITRANS P measuring instruments for pressure

SECTION A. NEC Compliance: Comply with NEC as applicable to installation and construction of electrical power/distribution transformers.

KEYSTONE SERIES GR RESIlIENT SEATED BUTTERFly VAlVES GRF

Differential pressure

PD662 LOOP-POWERED METER

Averaging PITOT Tube 5RD series

OMEGADYNE, INC. REVOLUTIONIZES SILICON PRESSURE TRANSDUCERS

JUMO flowtrans DP P. Pitot tube P01 to P04. Applications. Brief description. Special features. Customer benefits

IOHN Workshop Sum Up. DNV Høvik 15 August Ron Montgomery, IBM Ellen Sjølie, DNV Magne Valen-Sendstad, DNV

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

M5100 Heavy Industrial Pressure Transducer

LIQUID-SPECIFIC PRODUCT LINE: ABRASIVE LIQUID PUMPS SERIES DESCRIPTION OPERATING RANGE: IMPROVEMENTS NOMINAL FLOW RATES:

SPECIFICATION SHEET. Measurement method. Measurement range switching. cell. 1 /2 inch dia ppm. cylinder cell. 1 /4 inch dia.

Pressure and temperature transmitters ATM/T

1 29SEP03 ALL General update with miscellaneous changes in entire document.

VersaFlow Coriolis 200 Sensor for Mass Flow Specifications

I/A Series Coriolis Mass Flow and Density Meters for Standard and 3A Sanitary Applications Models CFS10 and CFS20 Mass Flowtubes

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Flow Through Toroidal Conductivity Sensor

Flow Rate Measurement In Emissions Monitoring

NRF CAPACITANCE LEVEL TRANSMITTER

SERIES 800 / 810 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTER ASSEMBLIES

Target Inline Flowmeter

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSHY (HY R-4E) Resistance thermometer for the food and beverage industries

Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables

SECTION MEDIUM VOLTAGE TRANSFORMERS

Electromagnetic flowmeters. dg: NEW. Sensor MUT 2200 EL DS100-2-ENG 1/12

Transcription:

Product Data Sheet 00813-0100-4235 Rev BA Rosemount 1152 Rosemount 1152 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std 323-1971 and IEEE Std 344-1975 Mild environment qualifications 4-20 ma or 10-50 ma output Panel or 2-inch pipe mounting 0.25% accuracy Contents Introduction........................................................ page 2 Transmitter Description............................................... page 2 Operation.......................................................... page 2 Dimensional Drawings................................................ page 3 Nuclear Specifications................................................ page 4 Performance Specifications............................................ page 4 Functional Specifications.............................................. page 5 Physical Specifications............................................... page 6 Ordering Information................................................ page 10 www.emersonprocess.com/rosemount/nuclear

Rosemount 1152 Product Data Sheet Results Driven by Proven Measurement Introduction Rosemount 1152 Alphaline Nuclear Pressure Transmitters are designed for precision pressure measurements in nuclear applications which require reliable performance and safety over an extended service life. These transmitters were qualified per IEEE Std 323-1971 and IEEE Std 344-1975 at radiation levels of 5 10 6 rads TID gamma radiation, seismic levels of 3 g, and for steam-pressure/chemical spray performance. Stringent quality control during the manufacturing process includes traceability of pressure-retaining parts, special nuclear cleaning, and hydrostatic testing. Transmitter Description Rosemount 1152 Transmitters are similar in construction and performance to the proven Rosemount 1151 Transmitters. Units are available in absolute (AP), gage (GP), differential (DP), and high-line differential (HP) configurations, with eight pressure range options. Direct electronic sensing with the completely sealed -Cell capacitance sensing element (see Figure 1) eliminates mechanical force transfer and problems associated with shock and vibration. Installation and commissioning are simplified by compact design, 2-wire system compatibility, and external span and zero adjustments. Wiring terminals and electronics are in separate compartments, so the electronics remain sealed during installation. Operation The completely sealed -Cell capacitance sensing element is the key to the unequalled performance and reliability of the Rosemount 1152 Pressure Transmitter. Process pressure is transmitted through an isolating diaphragm and silicone oil fill fluid to a sensing diaphragm in the center of the -Cell (see Figure 1). The reference pressure is transmitted in the same manner to the other side of the sensing diaphragm. The displacement of the sensing diaphragm, a maximum motion of 0.004 in. (0.1 mm), is proportional to the pressure differential across it. The position of the sensing diaphragm is detected by capacitor plates on both sides of the sensing diaphragm. Differential capacitance between the sensing diaphragm and the capacitor plates is converted electronically to a 2-wire, 4 20 ma or a 10 50 ma dc signal. FIGURE 1. The -Cell. Rosemount 1152DP, HP, and GP Lead Wires Isloating Diaphram Lead Wires Capacitor Plates Sensing Diaphragm Rigid Insulation Welded Seals Rosemount 1152AP Isolating Diaphragm Evacuated Absolute Reference Silicone Oil Capacitor Plates Sensing Diaphragm Rigid Insulation Welded Seals Silicone Oil 2

Product Data Sheet 4.5 Max. (114.3) FIGURE 2. Transmitter Dimensional Drawings ROSEMOUNT 1152 DP AND HP 4.5 Max. (114.3) Rosemount 1152 0.75 (19) Clearance for Cover Removal (typical) 7 /16 20 UNF (typical) 1.63(41.3) 9 Max. (228.6) 3.7 (94) 1 /4 18 NPT Pressure Connection Dim. (typical) A 3.4 (86.4) 1 /2 14 NPT Conduit Connection (2 places) Nameplate (remove for zero and span adjust) Transmitter Circuitry (this side) Terminal Connections (this side) Drain/Vent Valve (2) 7 /16 14 UNC (4 places) Pressure Range Code Dimension A ROSEMOUNT 1152 AP AND GP 3, 4, 5 2.13 (54) 6, 7 2.19 (55.6) 8 2.25 (57.2) 9 2.28 (57.9) 0 2.33 (59.1) 4.5 Max. (114.3) 4.5 Max. (114.3) 0.75 (19) Clearance for Cover Removal (typical) 9 Max. (228.6) 1 /2 14 NPT Conduit Connection (2 places) Nameplate (remove for zero and span adjust) Dim. A 7 /16 20 UNF (typical) 1.63(41.3) 1 /4 18 NPT Pressure Connection (typical) NOTE Dimensions are nominal in inches (millimeters). 3.7 (94) 3.4 (86.4) Transmitter Circuitry (this side) Terminal Connections (this side) Drain/Vent Valve (1) Blank Flange 7 /16 14 UNC (4 places) 3

Rosemount 1152 SPECIFICATIONS Nuclear Specifications Qualified per IEEE Std 323-1971 and IEEE Std 344-1975 as stated in Rosemount Reports 38019, 58225, and 117415; Rosemount 1152 with Output Code L (10 50 ma), seismic qualification only, per IEEE Std 344-1975 as stated in Rosemount Report D8800058. Radiation (4 20 ma only) Accuracy within ±8.0% of upper range limit during and after exposure to 5 10 6 rads, total integrated dosage of gamma radiation at 0.4 Mrad/hr dose rate. Seismic Accuracy within ±0.25% of upper range limit during and after seismic disturbance to 3 g over a range of 5 100 Hz in three major axes. Steam Pressure/Chemical Spray (4 20 ma only) Accuracy within ±0.75% of upper range limit after sequential exposure to steam at the following temperatures and pressures: 316 F (157.8 C), 70 psig (482.6 kpa) for 1 hour 303 F (150.5 C), 55.4 psig (381.9 kpa) for 7 hours 230 F (110 C), 6 psig (41.4 kpa) for 42 hours For SST housing option, accuracy within ±0.75% of upper range limit after chemical spray concurrent with the above system pressure cycle. Quality Assurance Program In accordance with NQA-1, 10CFR50 Appendix B, ISO 9001:2000, and CSA Z299.1. Nuclear Cleaning To 1 ppm chloride content. Hydrostatic Testing To 150% of rated line pressure or 2,000 psi (13.8 MPa), whichever is greater. 0 tested to 7,500 psi. Traceability In accordance with NQA-1 and 10CFR50 Appendix B; chemical and physical material certification of pressure retaining parts. Performance Specifications Product Data Sheet Based on zero-based ranges under reference conditions. Accuracy ±0.25% of calibrated span; includes combined effects of linearity, hysteresis, and repeatability. Dead Band None. Drift ±0.2% of upper range limit for 30 months. Temperature Effect s 4 9 and 0: ±(0.5% upper range limit +0.5% span) per ambient temperature change of 100 F (55.6 C). 3: ±(1.0% upper range limit +1.0% span) per ambient temperature change of 100 F (55.6 C). Overpressure Effect Rosemount 1152DP: Maximum zero shift after 2,000 psig (13.8 MPa) overpressure: Overpressure Effect 3, 4 ±0.25% of upper range limit 5 ±1.0% of upper range limit 6, 7 ±3.0% of upper range limit 8 ±6.0% of upper range limit Rosemount 1152HP: Maximum zero shift after 4,500 psig (31.0 MPa) overpressure: Overpressure Effect 4 ±1.0% of upper range limit 5 ±2.0% of upper range limit 6, 7 ±5.0% of upper range limit Rosemount 1152AP and 1152GP: 3, 4 5 8 9 0 Overpressure Effect 2,000 psig (13.8 MPa) will cause a zero shift of less than ±0.25% of upper range limit. 2,000 psig (13.8 MPa) will cause a zero shift of less than ±1.0% of upper range limit. 4,500 psi (31.0 MPa) will cause a zero shift of less than ±0.5% of upper range limit. 7,500 psi (51.7 MPa) will cause a zero shift of less than ±1.0% of upper range limit. 4

Product Data Sheet Rosemount 1152 Static Pressure Zero Effect Rosemount 1152DP: Per 2,000 psi (13.8 MPa): Power Supply Design limits are as shown in Figure 3 for 4 20 ma dc and 10 50 ma dc. Static Pressure Zero Effect 4, 5 ±0.25% of upper range limit 3, 6 8 ±0.5% of upper range limit Rosemount 1152HP: Per 4,500 psi (31.0 MPa): all Static Pressure Span Effect Effect is systematic and can be calibrated out for a particular pressure before installation. Correction uncertainty is ±0.25% of input reading/1,000 psi (6.89 MPa) (±0.5% of input reading/1,000 psi for 3). Power Supply Effect Less than 0.005% of output span/volt. Load Effect Static Pressure Zero Effect ±2.0% of upper range limit Load (Ω) Load (Ω) FIGURE 3. Transmitter Load Limitations. 4 20 ma dc 1650 1500 1000 500 0 1100 1000 500 Design Region 12 20 30 40 45 Power Supply (V dc) 10 50 ma dc Design Region 0 30 40 50 60 70 80 85 Power Supply (V dc) 1151-0191B No load effect other than the change in voltage supplied to the transmitter. Mounting Position Effect No span effect; zero shift of up to 1 inh 2 O, which can be calibrated out. Functional Specifications Service Liquid, gas, or vapor. Output 4 20 ma dc or 10 50 ma dc (seismic qualification only). Span and Zero Continuously adjustable externally. Zero Elevation and Suppression Maximum zero elevation: 600% of calibrated span (DP, GP, and HP only). Maximum zero suppression: 500% of calibrated span. Zero elevation and suppression must be such that neither the span nor the upper or lower range value exceeds 100% of the upper range limit. Temperature Limits Amplifier operating: 20 to 200 F ( 28.9 to 93.3 C) Sensing element operating: 20 to 220 F ( 28.9 to 104.4 C). Storage: 60 to 250 F ( 51.1 to 121.1 C). Humidity Limits 0 to 100% relative humidity (NEMA 4X). Volumetric Displacement Less than 0.01 in 3 (0.16 cm 3 ). 5

Rosemount 1152 Turn-on Time 2 seconds maximum. No warm-up required. Response Time Time constant at 100 F (37.8 C) continuously adjustable from 0.2 seconds or less (0.4 seconds or less for 3) up to 1.67 seconds nominal. Pressure Ranges Rosemount 1152DP and 1152HP: Pressure Range 0 5 to 0 30 inh 3 2 O (0 1.24 to 0 7.46 kpa) (DP units only) 4 0 25 to 0 150 inh 2 O (0 6.22 to 0 37.3 kpa) 5 0 125 to 0 750 inh 2 O (0 31.08 to 0 186.4 kpa) 6 0 17 to 0 100 psi (0 0.12 to 0 0.69 MPa) 7 0 50 to 0 300 psi (0 0.34 to 0 2.07 MPa) 0 170 to 0 1,000 psi (0 1.17 to 0 6.89 MPa) 8 (DP units only) Rosemount 1152AP and Rosemount 1152GP: Pressure Range 0 5 to 0 30 inh 3 2 O (0 1.24 to 0 7.46 kpa) (GP units only) 0 25 to 0 150 inh 4 2 O (0 6.22 to 0 37.3 kpa) (GP units only) 5 0 125 to 0 750 inh 2 O (0 31.08 to 0 186.4 kpa) 6 0 17 to 0 100 psi/psia (0 0.12 to 0 0.69 MPa) 7 0 50 to 0 300 psi/psia (0 0.34 to 0 2.07 MPa) 8 0 170 to 0 1,000 psi/psia (0 1.17 to 0 6.89 MPa) 0 500 to 0 3,000 psi (0 3.45 to 0 20.68 MPa) 9 (GP units only) 0 1,000 to 0 6,000 psi (0 6.89 to 0 41.37 MPa) 0 (GP units only) Maximum Working Pressure Rosemount 1152DP and 1152HP: Static pressure limit. Rosemount 1152AP and 1152GP: Upper range limit. Static Pressure and Overpressure Limits Rosemount 1152DP: 0.5 psia to 2,000 psig (3.4 kpa abs to 13.8 MPa) maximum rated static pressure for operation within specifications; overpressure limit is 2,000 psig (13.8 MPa) on either side without damage to the transmitter. Rosemount 1152HP: 0.5 psia to 4,500 psig (3.4 kpa abs to 31.0 MPa) maximum rated static pressure for operation within specifications; overpressure limit is 4,500 psig (31.0 MPa) on either side without damage to the transmitter. Overpressure Limits Product Data Sheet Rosemount 1152AP and 1152GP: Operates within specification from 0.5 psia (3.4 kpa abs) to upper range limit. Overpressure limit is 2,000 psig (13.8 MPa) without damage to the transmitter for all s, except 9, which has a limit of 4,500 psig (31.0 MPa) and 0, which has a limit of 7,500 psig (51.7 MPa). Physical Specifications Materials of Construction Isolating Diaphragms: 316L SST. Drain/Vent Valves: 316 SST. Process Flanges: CF-8M (Cast version of 316 SST). O-rings: Ethylene propylene. Fill Fluid: Silicone oil. Flange Bolts and Nuts: Plated alloy steel, per ASTM A-540. Electronics Housing: Low-copper aluminum with epoxy-polyester paint; or austenitic stainless steel. Mounting Bracket: Carbon steel, AISI 1010 or 1020, with epoxy-polyester paint; or 316L SST. Mounting Bolts (Bracket to Transmitter): SAE J429 carbon steel, Grade 2 or Grade 5. Process Connections 1 /4 18 NPT. Electrical Connections 1 /2 14 NPT conduit with screw terminals. Weight 12 lb (5.4 kg) with aluminum housing; 16 lb (7.3 kg) with stainless steel housing (excluding bracket). 6

Product Data Sheet Rosemount 1152 FIGURE 4. Electrical Block Diagram Sensor Demodulator Current Detector + Oscillator Osc. Control Amp. Voltage Regulator Curr. Control Amp. Current Limiter Reverse Polarity Protection Test + Signal Current Control 1154-0295A FIGURE 5. Wiring Connections + + Terminal Side Cover Removed Power + + Supply 1152-1152G05A 7

Rosemount 1152 Product Data Sheet FIGURE 6. Typical Rosemount 1152 Pressure Transmitter Exploded View Electronics Housing Circuit Boards Cover -Cell Sensing Module Process Flange Optional Panel Mounting Bracket 8

Product Data Sheet Rosemount 1152 FIGURE 7. Rosemount 1152 Typical Mounting Configuration 2.81 (71.4) 2.62 (66.5) 4.5 (114.3) Mounting Bracket for Aluminum Housing with Painted Carbon Steel Bracket Shown in Typical Mounting Configuration 2.81 (71.4) 4.10 (104) 1.41 (35.8) 2.62 (66.5) PANEL MOUNTING HOLE PATTERN 2.75 (69.9) 1.41 (35.8) 2.81 (71.4) 1.41 (35.8) 2.81 (71.4) 4.93 (125) Mounting Bracket for Stainless Steel Housing with SST Bracket Shown in Typical Mounting Configuration 5 (127) PANEL MOUNTING HOLE PATTERN 2.75 (69.9) 2.22 (56.4) 4.93 (125) Mounting Bracket for Pipe Mount Shown in Typical Mounting Configuration PIPE MOUNTING HOLE PATTERN 4.97 (126.2) NOTE All dimensions are nominal in inches (millimeters). 9

Rosemount 1152 Product Data Sheet ORDERING INFORMATION Model Description 1152 Alphaline Pressure Transmitters for Nuclear Applications Code DP HP AP GP Pressure Measurement Differential Pressure, 2,000 psig (13.8 MPa) Static Pressure Rating Differential Pressure, 4,500 psig (31.0 MPa) Static Pressure Rating Absolute Pressure Gage Pressure PRESSURE RANGES at 68 F Rosemount 1152DP Code (Differential) 3 0 5 to 0 30 inh 2 O (0 1.24 to 0 7.46 kpa) 4 0 25 to 0 150 inh 2 O (0 6.22 to 0 37.3 kpa) 5 0 125 to 0 750 inh 2 O (0 31.08 to 0 186.4 kpa) 6 0 17 to 0 100 psi (0 0.12 to 0 0.69 MPa) 7 0 50 to 0 300 psi (0 0.34 to 0 2.07 MPa) 8 0 170 to 0 1,000 psi (0 1.17 to 0 6.89 MPa) Rosemount 1152HP (Differential) Rosemount 1152AP (Absolute) Rosemount 1152GP (Gage) 0 5 to 0 30 inh 2 O (0 1.24 to 0 7.46 kpa) 0 25 to 0 150 inh 2 O (0 6.22 to 0 37.3 kpa) 0 125 to 0 750 inh 2 O (0 31.08 to 0 186.4 kpa) 0 17 to 0 100 psi (0 0.12 to 0 0.69 MPa) 0 50 to 0 300 psi (0 0.34 to 0 2.07 MPa) 0 25 to 0 150 inh 2 O (0 6.22 to 0 37.3 kpa) 0 125 to 0 750 inh 2 O (0 31.08 to 0 186.4 kpa) 0 17 to 0 100 psia (0 0.12 to 0 0.69 MPa) 0 50 to 0 300 psia (0 0.34 to 0 2.07 MPa) 0 170 to 0 1,000 psia (0 1.17 to 0 6.89 MPa) 0 125 to 0 750 inh 2 O (0 31.08 to 0 186.4 kpa) 0 17 to 0 100 psi (0 0.12 to 0 0.69 MPa) 0 50 to 0 300 psi (0 0.34 to 0 2.07 MPa) 0 170 to 0 1,000 psi (0 1.17 to 0 6.89 MPa) 9 0 500 to 0 3,000 psi (0 3.45 to 0 20.68 MPa) 0 0 1,000 to 0 6,000 psi (0 6.89 to 0 41.37 MPa) Code Output N (1) 4 20 ma dc with Adjustable Damping MATERIALS OF CONSTRUCTION Electronics Code Flanges Drain/Vent Valves Isolating Diaphragms Housing/Covers 22 316 SST 316 SST 316 SST Aluminum 92 316 SST 316 SST 316 SST Austenitic SST Code Options PB Panel Mounting Bracket PM 2-in. Pipe Mounting Bracket Typical Model Number: 1152DP 4 N 22 PB (1) For 10 50 ma output, the N is replaced with L, and T1805 is incorporated into the model number, unless another T option is required. For example: 1152DP5L22T1805PB. Transmitters with Output Code L have seismic qualification only. 10

Product Data Sheet Rosemount 1152 Standard Accessories One instruction manual is included with each shipment. Calibration Transmitters are factory calibrated to the customer s specified range. If calibration is not specified, transmitters are calibrated at maximum range. Calibration is at ambient temperature and pressure. Tagging The transmitter will be tagged, at no charge, in accordance with customer requirements (96 characters maximum). All tags are SST. The standard tag is permanently attached to the transmitter. Standard tag character height is 0.125 in. (3.18 mm). A wire-on tag is available on request. Documentation Certification of compliance will be provided for each Rosemount 1152 Pressure Transmitter for nuclear qualification, accuracy, special cleaning, hydrostatic testing, and traceability. Chemical and physical reports and identification of pressure-retaining parts will be on file at Rosemount Nuclear Instruments, Inc. 11

PRINTED Rosemount 1152 Product Data Sheet The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount, the Rosemount logotype, and Alphaline are registered trademarks, and δ -Cell is a trademark of Rosemount Inc. Cover Photo: 1152-001AB Emerson Process Management Rosemount Nuclear Instruments, Inc. 8200 Market Boulevard Chanhassen, MN 55317 IN U.S. A. Tel (952) 949-5210 Fax (952) 949-5201 Copyright 2007 Rosemount Nuclear Instruments, Inc. http://www.emersonprocess.com/rosemount/nuclear Rosemount Nuclear Instruments, Inc. satisfies all obligations coming from legislation to harmonize product requirements in the European Union. 00813-XXXX-XXXXm www.emersonprocess.com/rosemount/nuclear