April 2005 Uniclass L74216 CI/SfB (61.7)(27.2) X. Photovoltaic Systems

Similar documents
March 2011 Uniclass G5315 Cl/SfB. SOLAR PHOTOVOLTAIC GUIDE On-Top PV System

Enhancing the Redland range

Beautifully Integrated Solar PV48. Cl/SfB (47) Ng2

The IMERYS PHOTOVOLTAIC INTEGRATED PV SYSTEM. The flexible renewable energy system L74216 (61.7) R. Uniclass.

Solar PV your guide to generating clean electricity

PHOTOVOLTAIC SYSTEMS. Syllabus. 1 Photovoltaic systems

HIGH PERFORMANCE SOLAR THERMAL SOLUTIONS

lighten your load Integrated PV roofing systems

Installation Guide for Imerys Large Format PVt 60 Photovoltaic Panel

January 2010 Uniclass L521 Cl/SfB (47) N

BY HARNESSING THE POWER OF THE SUN WE ARE ABLE TO PRODUCE HOT WATER AND ELECTRICITY FROM AN INEXHAUSTIBLE SOURCE WITHOUT ADDING TO THE CARBON LEVELS

MOUNTING SYSTEMS PRODUCT CATALOG

Energise your façade with architecturally impressive Liberta Solar for building integrated photo-voltaic panel systems.

Leading in integration for partial- and full roofs: Photovoltaic in-roof mounting system Solrif by Schweizer.

IBC Mounting Systems. System solutions for all application areas

Letting air through... Keeping moisture out.

Contents. Contents. Module 1 Photovoltaic panels in context of renewable technologies 1

Solar PV Energy Management System. Turns surplus power into free hot water. dimplex.co.uk/free-e

Be Part of the Solar Solution Complete Systems for Solar Electricity and Hot Water

Fact sheet. Photovoltaic systems. Why consider photovoltaics?

How do weather, environment and location affect solar?

Cl/SfB (47) Ng2. June Village. Type Plain Tile with cross camber and weathered appearance Size 265 mm x 165 mm Material Natural Alluvial Clay

LEED & BREEAM: Get extra credits through renewable energy. Use the possibility to gain extra LEED and BREEAM credits.

Cl/SfB (47) Ng2. June Cassius. Thin Leading Edge Slate TBC

SOLARPVSYSTEM INFORMATIONPACK FIT PROGRAM

TREES Training for Renovated Energy Efficient Social housing. Section 1 Techniques 1.5 Photovoltaic systems

Letting air through. Keeping moisture out!

LAMILUX CI ENERGY CONSUMPTION-OPTIMIZED PHOTOVOLTAIC SOLUTIONS. Customized Intelligence Serving the customer is our first priority

Photovoltaic. - it is the main energy source of the planet since its inception 4 billion years ago and another 4 billion years it will be

Development of the Photovoltaic plant

Santa Monica Fire Department SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINE 2008 TABLE OF CONTENTS

Beverly Hills Fire Department SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINE 2008 TABLE OF CONTENTS

Cl/SfB (47) Ng2. April Rivius & Balmoral. Type Interlocking Riven Slates Material Natural Alluvial Clay Guaranteed for 60 years

FLAT ROOF PHOTOVOLTAIC SYSTEMS. BauderSOLAR

AN INTRODUCTION TO SOLAR PV & CASE STUDIES FROM CUMBRIA (& elsewhere!)

Hi-Point TM off-site roof system

Renewable energy from the sun Daikin solar thermal systems for the installer

Roofing and Cladding. ALTERNA NT-slate APPLICATION INSTRUCTIONS 11

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Cl/SfB (47) Ng2. September /20. Interlocking Clay Plain Tile. Now performs at pitches down as low as 15º

PHOTOVOLTAICS HISTORY OF PHOTOVOLTAICS

OVERVIEW OF BUILDING INTEGRATED PHOTOVOLTAIC INSTALLATION IN HONG KONG GOVERNMENT BUILDING

IMERYS Environmental Statement

FLAT ROOF PHOTOVOLTAIC SYSTEMS. BauderSOLAR

Metal Roo ng + Solar Arrays: The Perfect Combination. Photovoltaic Technology

IMERYS Environmental Statement

ASI Glass. Integrated Architecture Powered by the Sun

SOLAR-LINE. Roofing accessories for solar systems. Providing expertise in the installation of photovoltaic and solar thermal systems

GPC ONE PLANETS CONSULTANTS LTD

FACADE BS SOLAR SHADING SYSTEMS

Cl/SfB (47) Ng2. September Rivius & Balmoral. Interlocking Riven Slates

Harnessing the sun s energy to power our future.

Solar PV Nominated Technical Persons Criteria

PHOTOVOLTAIC INSTALLATION GUIDELINES

Powering solar-ready rooftops with PV panels

Bioclimatic Pergola with ajustable blades

solar photovoltaics (PV)

Ecotop VHT Flat plate solar collector (for forced systems)

Professional Photovoltaic Solutions.

Running the Electric Meter Backwards: Real-Life Experience with a Residential Solar Power System

The Imerys Phalempin Clay Plain Tile

TAKING DRY FIX FURTHER

Mounting System MCG 3.0 Membrane-Connected Glass. System description

CI/SfB (47) Ng2 July Neo Pantile New generation clay pantile

The Imerys Beauvoise 20 Clay Tile

5. Solar Photovoltaic System

Cl/SfB (47) Ng2. March Rivius & Balmoral. Interlocking Riven Slates

PV*SOL. The future is here. Simulation programs from Valentin Software. New: PV*SOL advanced

PV tiles and modules composition:

Rooftop Solar PV System Designers and Installers. Training Curriculum. APEC Secretariat

MARBLEHEAD FIRE DEPARTMENT Standard Operating Guideline Draft for Photovoltaic/Solar Installations

Benefits in Speed and Logistics using the RL System. snapnrack.com

SOLAR PV Oier Aranzabal LH Usurbil May 2012

Building Integrated PV systems. An installers perspective

Section 2: Sources of Energy

Installers Guide. Item

Technical Talk on HK s Largest Solar Power System at Lamma Power Station

LECTURE 15 PHOTOVOLTAIC MATERIALS. ECE 371 Sustainable Energy Systems

Contents. What is a solar water pump? 3-4. Smart Solar Water 5-6. Small Centrifugal Pump Systems 7. MPPT Diaphragm Pump Systems 8

Flat roof for the loading-optimized elevation (adhesive system)

For more information on Marley Eternit visit January Clay interlocking tiles

Cl/SfB (47) Ng2. November Romulus. Clay double roman tile

ONDULINE MINI 18. The stylish Do it Once roofing upgrade for your garden buildings.

SOLAR PHOTOVOLTAIC ASI GLASS E. ASI Glass. Integrated Architecture Powered by the Sun

Look Inside To Determine Your Home s Solar Energy Needs

RIS Roof Integrated Solar PV System

ASSESSMENT AND DESIGN OF ROOFTOP SOLAR PV SYSTEM. Click to begin

Lei Chu San Office for the Development of the Energy Sector, Macau SAR, China

MAKING CLEVER USE OF THE SUN

SUN LOUVRES. Allux Metal ceiling systems. Zagorska Jakovlje - Zagreb. Tel.: Fax:

SOLAR MODULES FOR ROOFTOP SYSTEMS AND SOLAR PARKS ENGLISH

Solar Photovoltaic Electricity Generation for Dairy Farms

7 Project Description

OPBW S.r.l. - Via Dell'Industria, Osimo (AN) - ITALY. Tel: (+39) Fax: (+39)

Reference: Photovoltaic Systems, p. 229

What is a solar water pump? 3-4. Smart Solar Water 5-6. Small Centrifugal Pump Systems 7. MPPT Diaphragm Pump Systems 8

Solar Energy to the Power of

The IMERYS. Clay PANtile DOUBLE PANNE S. A classic appearance with economical coverage

New versatile and effective dry fix solutions for the roofline and above

Solar Learning Lab. User s Guide. Heliotronics, Inc Main Street Hingham, MA (781) FAX (781)

Transcription:

April 2005 Uniclass L74216 CI/SfB (61.7)(27.2) X the range Photovoltaic Systems

You re better covered the Lafarge Roofing is part of the Roofing Division of the worldwide Lafarge Group. Operating in the UK and Ireland our goal is to deliver high-quality roofing solutions that perfectly meet our customers expectations. range Formerly known as Redland Roofing Systems, Lafarge Roofing draws on the expertise and experience gathered from more than 80 years as an industry leader. Today Lafarge Roofing offers the Redland range of tiles, slates, metal sheets, fittings and accessories which, combined with market-leading technical support services, enable us to deliver total pitched roofing solutions you can rely on. photovoltaic systems Lafarge Roofing offers two photovoltaic systems, both designed specifically to integrate with pitched roofs. This guide explains how photovoltaic systems work and the benefits they bring, as well as providing comprehensive technical data to assist with the correct specification and application of both the PV 80 and PV 800 systems. Introduction 1 Power stations for pitched roofs 3 PV 800 4-5 PV 80 6-7 Peace of mind 8 Technical Solutions 9

Increasing concerns over climate change and the depletion of fossil fuels are leading the drive towards generating electricity from renewable sources such as sun, wind, water and plant material. Of these renewable sources, the sun is by far the most powerful, with enormous amounts of solar radiation striking the earth s surface every day. Harnessing this energy has long been a goal of man, a goal that is now becoming a reality thanks to photovoltaic systems that turn daylight into 'green' electricity. 1

Introduction Photovoltaic tile systems, wonderful for your home and the environment Pitched roofs are ideal locations for photovoltaic systems but until recently fitting a photovoltaic system to a pitched roof meant having to bolt-on an unsightly frame. In response to this Lafarge Roofing have developed two integrated photovoltaic (PV) tile systems, minimising the aesthetic impact of PV on the building and the surrounding environment. Lafarge Roofing s PV tile systems are a technical tour de force, innovative and very reliable, but their aesthetics are just as important. Both systems are fully integrated with the roof covering and blend into the roof s surface beautifully. Pitched roofs are more suitable for PV installations than flat roofs since away from the equator the radiation from the sun strikes the earth at an angle rather than coming from directly overhead. Even in the UK, and even in winter, PV systems will continue to harness solar energy. Of course the brighter the sunlight the higher the output, but our PV systems also work well in normal daylight and even cloudy conditions. Lafarge Roofing s two PV tile systems are easy to install on both new build and renovation projects and can be expanded at a later date for maximum flexibility. 2

Power stations for pitched roofs Photovoltaic panels convert daylight into DC (direct current). An inverter turns this DC into the domestically usable 230V 50Hz AC. The installation is connected to the National Grid. As soon as the system starts supplying power, this power will be used in the home first. Any surplus electricity is sold to the National Grid (subject to agreement), and any shortages are made up from the grid network. Continuity of supply To ensure total continuity of supply, your rooftop power station is connected to the National Grid (subject to the agreement of the electricity provider). If you need more electricity than your unit produces, it is drawn from the grid, guaranteeing security of supply at all times, including during bad weather and at night. There is no need for expensive storage batteries. Angle of inclination of solar panel Disconnector Direct current wires Adapter cables Inverter 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 West 90 90 East 80 70 60 50 40 30 The percentages show the minimum possible solar yield as a function of the solar panel's orientation and its inclination in relation to the horizontal. 20 10 Solar panel is horizontal 100% 0 South 95% 10 20 90% 30 85% Panel cables Connection within the building Three-phase current meter 230 V End-user 80% 40 75% Consumer Load circuit Functional diagram Basic unit with 20 serially connected panels. 50 Solar panel is vertical (facade) 70% 65% 60 70 80 Rule of thumb: Photovaltaic systems make sense at up to 45 degrees deviation from south. Consumer Solar panel DC circuit AC circuit Circuit distributor and meter The ideal pitch Inverter for supply to the grid Branch box to the grid Solar panel SRT40 (PV800) SRT80 (PV80) The optimum situation for a solar energy system is a pitched roof. A roof, pointing at the sun, with a slope of between 20 and 50 degrees provides the best result. The best output is achieved when the installation is placed on the south-facing side of a roof, but it is also possible to use a roof orientated between south-east and south-west. The system should not be situated in the shade of high buildings or trees, as this will reduce its efficiency. National Grid 3Power stations for pitched roofs

PV 800 PV 800 Integrates perfectly with concrete roof tiles The beautifully sleek PV 800 system is an attractive alternative to traditional bolt-on PV panels and means that generating environmentally friendly electricity from daylight need not compromise a building's design. The PV 800 system contributes to a better environment in a responsible and above all beautiful way. The system is fully integrated amongst the roof tiles, creating a sleek and aesthetically pleasing roof surface. The panels have a dual function: they serve as solar power panels and as roof coverage, with the same weather-resistant and durable properties as traditional roof tiles that are mounted onto the tile battens. The panels overlap and are mounted in the same coverage size as the roof tiles, which means they follow the horizontal courses of the roof tiles. One PV 800 panel replaces exactly four roof tiles. The PV 800 system offers considerable flexibility in the way that the panels can be arranged on the roof to ensure that they are not shaded by higher parts of the building or by trees. The flexibility of this system enables aesthetically pleasing effects to be achieved, arranging the solar panels in either rectangular blocks, in rows, or in stepped formations. Since it is modular, the PV 800 system can easily be extended or adapted in the future without difficulty. Environmental awareness has rarely looked so good. The system consists of BP PV panels, type SRT 40, weather-resistant recyclable man-made cassettes, high-quality stainless steel mounting brackets and an inverter. Solar panel Solar panel trays Reinforcement bar Solar panel bracket Eave flashing element 4

PV 800 Superior aesthetics Perfect integration with a range of compatible roof tiles BP Solar photovoltaic cells Flexible modular system Complies with UK External Fire Exposure Roof Tests (BS 476 Part 3) For new build or renovation Easily installed and expanded Guaranteed weathertight Average yield of PV 800 solar power unit (on a roof of 30 pitch and southerly orientation without shade) compared to the yearly electricity requirement of a four person household (3,300 kwh) - excluding hot water and heating. 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 1,200 kwh Technical Data Polycrystalline solar cells, fitted with toughened glass on black base Size (one panel) 1194 x 378mm (Replaces four roof tiles) Cover (one panel) 0.4 m 2 Minimum Pitch 20 Maximum Pitch 50 Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing 310mm 340mm Weight laid weight at max gauge 13.3kg/m 2 per panel including fixings 5.7 kg Power Output 40Wp Open Circuit Voltage 1,800 kwh 2,400 kwh Type of unit 1.6 kwp 2.4 kwp 3.2 kwp 4.8 kwp No of panels 40 60 80 120 PV area m 2 16m 2 24m 2 32m 2 48m 2 3,600 kwh 3,300 kwh Average yearly electricity requirement 11V Short-circuit Current 4.8A Compatibility Landmark Double Pantile, Grovebury, 50 Double Roman, Renown, Mini Stonewold. For guidance on compatibility with other tiles and slates, please contact our Technical Solutions Hotline on 08708 702595. 5PV 800

PV 80 PV 80 A flexible solution for tiled, slated and metal roofs Whether the sun is shining brightly or it's cloudy, a photovoltaic installation such as the PV 80 system will always do its job. The system turns daylight plentiful and free directly into electricity. An investment in a PV 80 system will therefore have immediate returns, and it is good for the environment. The PV 80 system is a universal solar power system that can be fitted with most roof coverings. Whether the roof is covered in profiled tiles, flat tiles, slates or metal sheets, PV 80 will provide a beautiful integrated solution. Panels are mounted directly onto the tile battens and specially designed eave, side and top flashing elements ensure the roof remains weathertight. PV 80 panels are larger than those used in the PV 800 system and therefore supply a higher peak power per square metre. The PV panel array must be rectangular or square but a system can be of almost any size. The PV System works grid connected within the parallel mains electrical network. The PV configuration must be rectangular or square and a system can be almost any size. PV 80 is supplied as a complete package with BP PV panels, type SRT 80, provided with mounting profiles, gutter pieces, cabling and a power inverter. Solar panel Top flashing element Side flashing element Foam strip Side flashing element Eave flashing element 6

PV 80 Universal fixing system BP Solar photovoltaic cells High electricity yield per m 2 For new build or renovation Easily installed and expanded Guaranteed weathertight Average yield of PV 80 solar power unit (on a roof of 30 pitch and southerly orientation without shade) compared to the yearly electricity requirement of a four person household (3,300 kwh) - excluding hot water and heating. 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 1,200 kwh Technical Data 1,800 kwh 2,400 kwh Type of unit 1.6 kwp 2.4 kwp 3.2 kwp 4.8 kwp No of panels 20 30 40 60 PV area m 2 12.4m 2 18.6m 2 24.8m 2 37.2m 2 Polycrystalline solar cells, fitted with toughened glass on black base Size (one panel) 1197 x 530mm (1200 x 520mm installed) Cover (one panel) 0.62 m 2 Minimum Pitch 25 Maximum Pitch 60 Minimum Gauge/Batten Spacing Maximum Gauge/Batten Spacing 3,600 kwh 3,300 kwh Average yearly electricity requirement n/a n/a Weight laid weight 11kg/m 2 per panel including fixings 6.8 kg Power Output 80Wp Open Circuit Voltage 22.1V Short-circuit Current 4.8A Compatibility Compatible with a wide range of tile and slates, please contact our Technical Solutions Hotline on 08708 702595. 7PV 80

Peace of Mind Peace of mind with long-lasting, weatherproof protection Like all products from the Redland range, our PV systems have been tested under storm and driving rain conditions at our unique wind tunnel facility, and are designed to meet the same wind uplift loads as the surrounding roof. Both systems are covered by the comprehensive Redland 15 Year Roof System Guarantee, when used with the Redland range of tiles and slates. The panels also carry a 25 year energy performance guarantee. Proven technology that is easy to install All PV systems from Lafarge Roofing are designed to be highly efficient and simple to build in. 8 The systems make use of highperformance standard components to deliver a high degree of efficiency. We provide a 25 year guarantee of a panel s electrical performance and, because there are no moving parts, the whole system is largely maintenance-free. The PV panels are connected in series, using ready-fitted plugs and sockets which are safe to handle and cannot be connected the wrong way round. Each PV panel array is connected to an electrical inverter which converts the direct current generated by the system into an alternating current supply which matches and is synchronised with the building s grid supply. For further guidance on the Redland range of PV systems: telephone our Customer Service Hotline on 08705 601000 Whether it is a new building or renovation project, trained installers can assemble and install panels as well as connect the PV system to the grid. You will get a good-looking, secure roof plus environmentally friendly electricity on top. Lafarge Roofing is committed to giving you complete roofing solutions and as part of that commitment we can provide you with step-by-step help with the planning and installation of your PV tile system, including explaining how to access grants available for the installation of PV systems. We can help you to assess the merits of solar energy for your particular project and calculate the size of the PV system needed. We can advise you on how best to approach your electricity supplier to arrange connection to the grid and to be credited with any surplus electricity which you might feed into the grid. Then we can help you to plan the details of the system how best to lay out the PV array to avoid shading, where to install the inverter and how best to connect it to the array. Buildings are the UK s largest user of energy and you could lead the shift towards a clean energy future. You will be installing proven technology which will add real long term value to your building and demonstrate your commitment to an environmentally responsible way to generate electricity for the future.

Time saving, flexibility, peace of mind Lafarge Roofing has developed a comprehensive range of FREE technical services that will save you time and give you peace of mind that your project is in safe hands EcoMaster Still working on that CAD drawing? DesignMaster Weighed down with specification detail? A complete guaranteed roof specification service Relieves the burden of the specification writing process Tailored specification clauses in NBS based format Fully compliant to all relevant British Standards QuantMaster Confident with your fixing specification? FixMaster Need help with those tricky calculations? A roof component quantity estimating service Quantifies all roof components as well as associated materials such as tiling battens and leadwork Eliminates potential costs of overordering or downtime resulting from under ordering To obtain a QuantMaster send your drawings to Technical Solutions A comprehensive CAD library of over 5,000 quality roofing drawings Saves time preparing working drawings Prevents risk of incorrect application Drawings available in both DWG and DXF formats Each drawing includes a complementary NBS based specification clause 15 year design liability guaranteed for all roofs designed and built in accordance with EcoMaster Provides peace of mind for you and your clients To obtain a EcoMaster contact the Technical Solutions Hotline Available for download at www.lafarge-roofing.co.uk/designmaster or DesignMaster CD-ROM available An advanced fixing specification service tailored to individual roof designs Removes the potential for roof failure Provides the most cost-effective fixing specification for tiles and battens that complies with British Standards Full assessment of the impact of all nearby man-made and natural topographical features To obtain a FixMaster contact the Technical Solutions Hotline For further information on Technical Solutions: Technical Solutions Hotline 08708 702595 technical@lafarge-roofing.co.uk Technical Solutions, Lafarge Roofing, Broadway Lane, South Cerney, Cirencester, Gloucestershire GL7 5UH 9Technical Solutions

Customer Service Hotline For all enquiries, call or fax our dedicated Customer Service Hotline and you will be automatically connected to the representative dealing with your area. Telephone 08705 601000 * Facsimile 08705 642742 www.lafarge-roofing.co.uk E-mail sales@lafarge-roofing.co.uk Technical Solutions For technical enquiries please contact Technical Solutions directly. Technical Solutions, Lafarge Roofing, Broadway Lane, South Cerney, Cirencester, Gloucestershire GL7 5UH Telephone 08708 702595 Facsimile 08708 702596 E-mail technical@lafarge-roofing.co.uk * When calling the Customer Service Hotline your telephone conversations may be recorded for training purposes. Head Office Lafarge Roofing Limited Regent House Station Approach Dorking Surrey RH4 1TG Your local stockist of the Redland range is: DESIGNED BY TGV, LONDON LIT015 APR05