The superior self-compacting concrete

Similar documents
INFORMATION AGILIA HORIZONTAL

BREEDONFlow SELF-COMPACTING CONCRETES AND FLOWING SCREEDS.

TECHNICAL INFORMATION

AFRISAM READYMIX OUR QUALITY PROMISE

The ultimate free-flowing floor screed

Ribdeck AL STRUX 90/40. efficient designs. with. shallow slabs. fibre reinforced concrete

No reinforcement required 40mm minimum - Commercial applications. 35mm minimum - Domestic applications.

Construction Specification for Unshrinkable Fill

Construction Specification for Unshrinkable Fill

SCREED A. The ideal free-flowing floor screed

View Publication. View publication chosen. Return to publications list. You have asked to view a publication

Design Guidance for TAB-Deck Composite Slabs using SMD Metal Decking reinforced with ArcelorMittal Steel Fibres

The ultimate high early strength concrete

Technical Manual. The difference is.

Good Construction Practices Part I

ATCE--I. Properties of Fresh Concrete. Advanced Topics in Civil Engineering Properties of Fresh Concrete Concrete ATCE-I I

This specification refers to the latest (current) edition of the following: For the purposes of this specification the following definitions apply:

THE CUPOLEX SOLUTION EXPANSIVE SOILS. www. cupolex.ca

Concrete. Chapter 10 Properties of Fresh Concrete. Materials of Construction-Concrete 1. Wikipedia.org

Drawings shown within this brochure is the Preston CarPark Innovation Concept and patents filed in August 2018.

Locrete Building System: the Technology Handbook

EUROACCESSORIES COLUMN FORMERS

Lecture 13 CONCRETE WORKS

CONSTRUCTION SPECIFICATION FOR CONCRETE SIDEWALK AND CONCRETE RAISED MEDIAN INDEX TS SCOPE...3 TS DEFINITIONS...3

SELF-COMPACTING CONCRETE- SCC

CONSTRUCTION SPECIFICATION FOR CONCRETE CROSSWALK INDEX TS SCOPE...3

Supaflow HF Grout. Dual Expansion Class C Grout. Description. Areas of application. Features

Low Maintenance Slabs Supports Are Needed for Long-Term Performance of Welded Wire Reinforcement In Slabs-On-Grade

REQUIREMENTS FOR CONCRETE MIX DESIGN

Modcrete. Modcrete OVERVIEW COMPONENTS COMPONENTS

DEVELOPMENT AND APPLICATIONS OF SELF-COMPACTING CONCRETE IN NEW ZEALAND

B BASF MasterFlow MasterFlow MasterFlow MasterFlow C CGM Grout...8

The ultimate low shrinkage flooring solution

Dock shelter and dock seal Full choice of dock shelters and dock seals can be included, refer to Stertil Stokvis brochure.

FEBFLOW STANDARD WATER REDUCING PLASTICISER FOR CONCRETE

Concrete. Copyright: Quasar Management Services Pty Ltd

NEW PERFORMANCE CRITERIA FOR FRESH TREMIE CONCRETE

What s Gray, Gets Hard, and Holds Up Your Home?

Learning Objectives. A Brief History

Trends in commercial concrete. construction systems

SELF COMPACTING CONCRETE FOR LNG TANKS CONSTRUCTION IN TEXAS

Fosroc Solutions for Admixtures. constructive solutions

Dr. Ahmed Hussien Elyamany 2017 Questions

PROJECT CONTRIBUTORS

PAN PAC PULPMILL TREATMENT TANK

CONCRETE PRODUCT GUIDE Concrete

SPECIFICATION 1035 M

ITEM No. D E S C R I P T I O N UNIT QTY. 5-E343.2 In class III material m³ 1,260 - Max. Depth: m For disposal

Inverted Double T BEAMS and SLABS Applications

Prestressed Hollowcore Slabs PRECAST CONCRETE SOLUTIONS.

Hollow Core Slabs Applications

MODERN CONCRETE TECHNOLOGY AND PLACEMENT METHODS AND THEIR INFLUENCE ON WATERPROOFING PERFORMANCE OF DIAPHRAGM WALLS M.D.

INSTITUTE OF CONCRETE TECHNOLOGY CONCRETE TECHNOLOGY & CONSTRUCTION Stage 2: GENERAL PRINCIPLES Learning objectives

G. Shop drawing of wall with all dimensions, details, and finishes. Drawings must include post foundations.

Section 1 - Introduction 1.1 Introduction Welcome to Fox Blocks. You have made an excellent decision to use Fox Blocks Insulated Concrete Forms (ICFs)

A. Section includes cast-in-place concrete, including reinforcement, concrete materials, mixture design, placement procedures, and finishes.

SECTION DRILLED CONCRETE PIERS AND SHAFTS

Assalamualaikum & Good Morning (May All Of You Gain A Better Understanding)

Hanson Multicem is manufactured to comply with the requirements of BS EN CEM II/A-LL (Portlandlimestone cement) strength class 32,5R.

SCC IN SOUTH AFRICA THE CHALLENGE TO INTRODUCE A NEW TECHNOLOGY TO THE CONSTRUCTION INDUSTRY

PRESENTATION PLAN A MODEL COMPARISON FLOOR CONSTRUCTION

Construction Innovations / Sustainability

Concrete Design & Placement

Fosroc Solutions for On-shore Wind Turbines.

CI/SfB. (Ff2) June 2007 CIVIL E NGINEERING PRODUCTS STEPOC SYSTEM. innovators in masonry

FAST SETTING and FAST CURING MORTAR NATCEM 35

Construction Management Study

PRODUCT DATA SHEET. Sika UCS Pak PRODUCT DESCRIPTION. Underwater / Anti Washout Admixture

SECTION US Patent 8,857,130 B1 CAST-IN-PLACE CONCRETE WITH ARDEX CONCRETE MANAGEMENT SYSTEMS (ACMS ) EARLY MC APPLICATION

Assessing the costs and benefits of reducing waste in construction

SECTION CONCRETE CURBS, GUTTERS AND SIDEWALKS

This section applies to the design and installation of cast-in-place concrete, shotcrete, precast concrete, and post-tensioned concrete.

Special Provision No. 799F01 March 2012 CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF NOISE BARRIER TABLE OF CONTENTS

OUR OBJECTIVE: TO PROVIDE EDUCATION ON AN ALTERNATIVE TO TRADITIONAL CONCRETE FORMWORK FOR WALLS

FASTPATH. The ultimate one pass footpath surfacing solution AGGREGATES AND ASPHALT

HEALTH AND SAFETY MANUAL

JANURY Siphonic Roof Drainage

INFORMATION KIT 2018 COPYRIGHT 2018 PENTABLOCK WORLWIDE PTY LTD

Siphonic Rainwater Drainage

product range HAMPTON LONSDALE BRIGHTON COVE BLACKWOOD MCLAREN SORRENTO E:

INSTALLATION METHOD STATEMENT

PERFECT SLABS Bernie de Klerk

Special Provision No. 599F01 May 2004 CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF NOISE BARRIER TABLE OF CONTENTS

CONCRETE. Composition of concrete mix. Classification and uses. Mix proportions and quantities CHAPTER 7. Plain Concrete. Reinforced Concrete

COST COMPARISON DINCEL vs AAC WALLS

INDEX FOR SPECIFICATIONS FOR JACKING CULVERTS THROUGH EMBANKMENTS SCOPE... 2

TECHNICAL REPORT. Fiber Reinforced Concrete Pumping High-Volume Fibers. December 2011 TR FORTA Corporation

IS : Dr. S. RAVIRAJ

Heavy Rib. Page 1 of 6. Expanded Mesh & Metal Products. Key Product Features:

INTERNSHIP REPORT GOUTHAM.J

Stylite. T-Beam Suspended Floor Insulation Technical Datasheet. Stylite T-Beam Floor Insulation

Krystol Internal Membrane (KIM ) Guidelines and Procedures - NZ

Civil Engineering Construction Chapter 5

Application Guide for MasterTop Dry Shakes MasterTop 200

Setting holding down bolts Floor screeds Bedding blocks Stone and bricks In contact with potable water Fine moulding.

SECTION RIGID PAVEMENT. 1. Portland Cement Concrete (PCC) pavement. 2. Section Aggregate Base Course.

High Performance Insulating Concrete Form

CONCRETE WORK CONCRETE WORK. Underground Electric Distribution Standards I. SCOPE APPLICABLE STANDARDS

SECTION CAST-IN-PLACE CONCRETE

Performance Floors for Warehouses and Distribution Centres. Kevin Dare, Managing Director, Face Consultants Ltd.

Transcription:

LAFARGE READYMIX The superior self-compacting concrete

The superior selfcompacting concrete THE ADVANTAGES ARE IMPRESSIVE REDUCES LABOUR COSTS Lafarge has developed a superior range of concretes in response to the challenges of the fast-moving construction industry. The new concretes are specifically designed to save time, give greater ease of use and, of course, reduce costs. Agilia offers huge benefits and cost savings by allowing placement of concrete in difficult situations and complex formwork. It is quick and easy to place, needs no vibration and moves effortlessly through highly congested reinforced areas, with no bleeding or segregation. Faster, unassisted placing means lower site costs with reduced risks and exposure to noise and vibration. Agilia Concrete also provides a quality surface finish better than conventional vibrated concrete, with excellent strength and durability. It is particularly suitable for mass concrete pours, bridge decks, walls, columns, slabs, trenches and precast applications. SAVES VALUABLE TIME ELIMINATES ALL VIBRATION Pouring the mix was simplicity itself, it is simply pumped into the buildings and requires only minimal finishing to create a self-levelled surface. For more information on products call 0870 336 8258

This concrete reduces labour overheads on site typically one man can place, level and finish the concrete. Agilia Trenchflow is a self-compacting concrete for use in all mass fill concrete foundation applications. It is delivered in a highly fluid form with high deformability that will quickly allow changes of direction and enables it to flow easily around foundation trenches. Agilia Trenchflow has a high resistance to segregation and the way it consolidates within the trench removes the need for vibration. BENEFITS REDUCED LABOUR Typically one man can place, level and finish the concrete. NO VIBRATION This procedure requires no vibration, eliminating the inherent problem of vibration white finger and reduced noise pollution. FLEXIBLE PLACING Agilia Trenchflow s properties allow house foundations to be typically poured from one or two discharge points. READY IN 24 HOURS Early strength mix achieves sufficient strength typically at 24 hours to allow the bricklaying process to proceed. CASE STUDY D. PALMER SELF-BUILD, HEMMINGFIELD David Palmer, Self-Build Project Hemmingfield A self-build on a rectangular plot which had access from the front and side. The footing was 17m in length. A site visit was made by Lafarge Readymix technical experts to assess access and agree the best method of discharge. There were two reasons for using Agilia Trenchflow. Firstly, there was a lack of labour and equipment on the site. Secondly, Agilia is quick and easy to use, saving valuable time. One man finished this job within 3 hours. Supplied from a local plant in Barnsley, South Yorkshire, only 4 miles from the project. The customer was pleased with the delivery times and service he received in addition to the superior product performance. In total, he purchased 50m 3 of Agilia Trenchflow. SPECIFICATIONS Maintenance of fluidity 1 hour Compressive strength at 28 days 20N/mm 2 (or to customer s specification) SAVINGS Item Agilia Normal Labour 1 man 3 men Plant Vibrator 0 1 Plant Excavator 0 1 COMPLETE FILL Fills the trench completely, leaving no voids, with little or no surface bleeding or surface laitence. NO ADDITIONAL TREATMENT Does not segregate or require the addition of water on site to aid placement of the concrete. There is no need for a subsequent admixture. INDIVIDUAL SPECIFICATIONS Agilia Trenchflow can be formulated to suit all environmental classifications. STEEL REINFORCEMENT IN TRENCH Flows easily around all types of trench, even those containing steel reinforcement.

Horizontal Agilia Horizontal s finishing characteristics and high quality surface finish often mean the elimination of the use of power-floated concrete on site. Agilia Horizontal is a self-placing, self-compacting concrete which enables the rapid and effortless fabrication of slabs and floors whilst obtaining a high quality surface finish. BENEFITS QUALITY SURFACE FINISH Agilia Horizontal s finishing characteristics and high quality surface finish often mean the elimination of the use of powerfloated concrete on site. Floor finish tolerance to BS 8204-1 SR2. FLEXIBLE PLACING Can be placed directly from the truck-mixer chute, pump, conveyor belt or craned skip. REDUCED LABOUR Agilia Horizontal is convenient, saves time and permits the flexible use of labour on the building site. CASE STUDY HALLAM CONTRACTS, LEICESTER Hallam Contracts, New Student Accommodation, Leicester The building is in the middle of an existing residential area. By using Agilia Horizontal, the contractors were able to pour each elevation in one, eliminating late finishes with power floats, and hence totally eliminating site noise outside normal working hours. Using Agilia Horizontal enabled the contractor to double their pour size and brought back the time lost on programme on constructing the first 4 floors using conventional concrete. SPECIFICATIONS Maintenance of fluidity 2 hours Compressive strength at 28 days 35N/mm 2 (or to customer s specification) Drying shrinkage at 28 days < 0.055µm/m Minimum thickness = 50mm SAVINGS Costings Agilia Normal 8x300/400m 2 floors poured 4 days 14 days Labour 4 staff 6 staff NO VIBRATION This procedure requires no vibration, eliminating the inherent problem of vibration white finger and reduced noise pollution. APPLICATION Can be used typically in the following applications; slabs, structural toppings and oversite. NOISE Elimates traditional methods of placing and finishing concrete. Ideal when working in inner-city and built-up residential areas. The concrete gang consisted of 4 workers who typically placed and finished between 600 690m 2 daily over a 4-day period.

Vertical An exceptional quality of surface finish is obtained, removing the need for any remedial work. Agilia Vertical is a self-compacting concrete for use in walls and columns in all types of building construction. BENEFITS QUALITY SURFACE FINISH As an added benefit of the Agilia technology, surface finish of the highest quality may be obtained. NO REMEDIAL WORK The highly fluid material will replicate the shape and texture of the formwork and so can be used in design applications. NO VIBRATION This procedure requires no vibration, eliminating the inherent problem of vibration white finger and reduced noise pollution. REDUCED LABOUR Agilia Vertical is convenient, saves time and permits the flexible use of labour on the building site. CASE STUDY NORTHFIELD CONSTRUCTION, LOUGHBOROUGH Northfield Construction Ltd Loughborough University A large retaining wall was required of between 4.5m and 4.9m. The client and architect required the visible face of the wall to have high quality finish equal to a BS 8110 Type B. Agilia Vertical was recommended and each pour was completed typically in less than one hour, using a crane and two operatives. No vibrators were used. For some of the wall pours, the reinforcement was more congested requiring the tremie pipe to be no wider than 40mm; even under such arduous conditions, Agilia Vertical delivered the same quality of finish with little difference in placing rate. The exposed surface can be seen in the illustration and required no further. SPECIFICATIONS Maintenance of fluidity 2 hours Compressive strength at 28 days < 35N/mm 2 (or to customer s specification) Water/Cement ratio As specified by the client SAVINGS Item Agilia Normal Crawler crane skip etc. 40/hr 1.25 3 Placing 2 staff 1.25 3 Vibration 2 staff Nil 3 Vibration equipment 4.5/hour Nil 3 Surface remedials Nil 3 Shutter remedials Nil 3 TOTALS 91 384 COST PER CUBIC METRE 5 22 NOISE Eliminates traditional methods of placing and finishing concrete. Especially important in inner-city and built-up residential areas. FLEXIBLE PLACING Can be placed either by pump, crane or skip. Note: Due to its high quality, Agilia Vertical mix designs are designed for each specific contract once such factors as placing techniques and strength requirements are known.

Force Flows easily through highly congested, heavily reinforced areas. Agilia Force has been designed to meet the demands of any type of construction. Its self-compacting properties make this concrete suitable for any job having areas of difficult access or complex formwork configurations. BENEFITS NO VIBRATION This procedure requires no vibration, eliminating the inherent problem of vibration white finger and reduced noise pollution. FLEXIBLE PLACING Flows easily through highly congested, heavily reinforced areas. Its highly fluid and cohesive properties also make Agilia Force suitable for jobs where access is difficult such as bridge spans, where longer pumping distances are involved. REDUCED LABOUR As a result of the ease of placement, large pour sizes are achievable with reduced labour and plant requirements. CASE STUDY WINSON GREEN PRISON, BIRMINGHAM Winson Green Prison Birmingham 350m 3 of Agilia Force was supplied for use on Winson Green Prison for concrete walls containing dense steel reinforcement and services. The walls were finished to a high quality surface finish which saved money through considerable reductions in labour. SPECIFICATIONS Compressive strength at 28 days 20-40N/mm 2 (to suit specification) Maintenance of fluidity typically > 2 hours Water/Cement ratio As specified by the client SAVINGS Time saved 2 weeks of contract recovered using Agilia NOISE Eliminates traditional methods of placing and finishing concrete. Especially important in inner-city and built-up residential areas. Costs saved Full site costs of 11,000

NBS Plus Lafarge Aggregates Limited PO Box 7388 Granite House Watermead Business Park Syston Leicester LE7 1WA For further information and advice about ordering and installing Lafarge products, call 0870 336 8258 or see our website. Our products and services include: AGGREGATES READYMIX F ASPHALT CONTRACTING WASTE DISPOSAL, RECOVERY & RECYCLING Other Lafarge UK companies include: Lafarge Cement Lafarge Roofing Lafarge Plasterboard Lafarge Gyvlon Please note: This map shows all Lafarge sites at the time of going to press, but new sites are opening all the time and some sites may not be able to offer all products. www.lafarge-aggregates.co.uk Was this brochure useful to you? Was it informative and easy to understand? Please send your feedback to: literature@lafarge.com This paper is manufactured from a sustainable resource. AG/6447/04-06/5K