Technical Compendium CDI. Blood Parameter Monitoring System 500

Similar documents
Clinical Evaluation of a New In-Line Continuous Blood Gas Monitor

What makes the technology unique?

Get a Closer Look. Continuing Support

Cedex Bio Bioprocess Analyzer. Be Confident. Be Assured.

Harvesting a New Standard of Care

Abbott istat for Blood Gas Analysis: The Halifax Perfusion Experience

Run critical care tests reliably and economically in low-volume settings

Design and implementation of a microchemistry analyzer

UNRIVALED SIMPLICITY. Exceptional Ease of Use. The STAR brings new meaning to the word simple

autolog Autotransfusion System

The Simple Solution for CBC Testing

luminometer.committed

i-stat iccnet CHSA Edition 1.2 Page 1 of 7 i-stat Rosy Tirimacco / Paul Simpson

Proxima. pco 2 and Calculated values for HCO 3 - and Base Excess on Proxima

INSPIRE Oxygenator Family

Dry Hematology Analyzer Fast, Simple CBC Analysis Designed for the Point of Care

A Dedicated Perfusion Electronic Medical Record with Discrete Epic Integration

CARTRIDGE AND TEST INFORMATION

Proxima. pco 2 and Calculated values for HCO 3 - and Base Excess on Proxima

APPLIED. OiW-100 Oil in Water Analyzer

Using the PPM2 Portable Trace Moisture Transmitter

Fpollutant-free zero air for analytical

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

This document is a preview generated by EVS

ASSESSMENT OF THE ACID BASE BALANCE

AUTOLOG. Autotransfusion System. A simple, yet sophisticated system.

EXM500. Online Gas Analyser. Specialist Of UV Spectroscopy

Affinity NT. Clearly the Choice for Consistent Performance. and Reliable Results

Affinity NT. Clearly the Choice for Consistent Performance. and Reliable Results

Dräger Jaundice Meter JM-105 Jaundice Management

Model Product Description and Specifications

The Process TDLS Solution

UniGas Hand-held combustion gas analyzer with 4 sensors

Chemical Oxygen Demand

IRIS Serial Configuration for Galaxy Upload/Download Connections:

The Advantages of Automatic Quality Control (AQC) for Blood Gas Testing QC

MPM 100 Monitor Product Description Guide

SAFETY PROCESS INDUSTRY LABORATORY & RESEARCH

Product Service Remote Service. Basic Information

Quantum Perfusion Systems

TEMPERATURE CONTROL SOLUTIONS FOR MATERIAL AND COMPONENT TESTS

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

SPECTRA OPTIA APHERESIS SYSTEM

Xpansion Multiplate Bioreactor System

IWAKI CHEMICAL GEAR PUMPS GM-V

Excellence in gas analyzers since Over 186 years of Jobin Yvon optical experience. The expertise of HORIBA combustion technology

COLow COHigh COLow/H 2

COLow COHigh COLow/H 2

LIQUID METER TYPE FMO

Single-Use Sensors. TruFluor and TruTorr Excellence in bio-processing measurement

Buffer In-line Dilution: Superior Performance with Volume Based Control. Mary Jo Wojtusik, Ph.D.

COLow COHigh COLow/H 2 NO 2 CO 2 H 2 S SO 2 C X H Y LANCOM 4. Portable Flue Gas Monitoring. comp NO NOx

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

TARGAS-1. Portable Photosynthesis System. Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring

SpectraMax Multi-Mode Microplate Readers

Model Product Description and Specifications

PITOT TUBE THERMO ANEMOMETER

EuroFID Total Hydrocarbon Analyzer

Dräger Mounting System Medical Supply Units

GAS 3050P NDIR FLUE GAS

REAL-TIME DUST MONITOR TEOM 1405-F

8 stream capability with dual mode (H 2 S & total Sulphur)

Precision Optical Oxygen Measurement 4401OXY Oxygen Analyzer & BOS Sensors

Newer techniques for extracorporeal lung support. Antonio Pesenti University of Milano Bicocca Italy

SIWAREX WP231 Flexible weighing module for S and stand-alone operation. Calibrating SIWAREX WP231 with SIWATOOL V7

MMS-TL Series Materials Management System Tank Level. ISO-9001:2000 certified. More than just another level measurement company.

CYTOPERM 2 CO 2 - AND CO 2

IMPAC Infrared Thermometers

So advanced, it s simple. So simple, it s revolutionary.

MAX300-BIO PRODUCT NOTE. Bioreactor/Fermentation Control Process Efficiency Product Quality Analysis. Bioreactor/Fermentation Mass Spectrometer

Minimizing Ammonia Consumption in DeNOx Plants In situ Laser Gas Analyzer LDS 6 Monitors NH 3 Slip in Real-time

CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy

Total Solution for Syngas Analysis

Technical article. Making reliable use of digester gas energy

Hach Method Luminescence Measurement of Dissolved Oxygen (LDO ) in Water and Wastewater

REQUEST FOR WRITTEN QUOTATION

MS-70/ MX-50 MF-50/ ML-50

RECENT IMPROVEMENTS IN AIR FLOW CALIBRATION REFERENCE INSTRUMENTS

INFRALAB MEAT ANALYZER

Product data sheet DUMATHERM N Pro. for the automatic serial determination of NITROGEN

User s Guide OM240. Linear & Polynomial Conversion. Shop online at omega.com SM

I-STAT POCT System PRINCIPLE:

Low Energy Consumption, High-Speed Productivity LCG 3015 AJ. Fiber Laser Cutting System

INFORS HT Product Guide: Visiferm DO Optical Oxygen Sensor

EMD Rs... must be deposited along with quotation. Quotation must be submitted into two Bid System 1) Price Bid 2) Technical Bid

SmartSpec Plus spectrophotometer

Optimize Your Process Operations by Improving Process Monitoring

AUTOMATIC SYSTEM FOR CLEANING, DISINFECTING AND LUBRICATING ROTARY INSTRUMENTS

Multidrop. The most precise and reliable reagent dispensing solution. Analyze Detect Measure Control TM

Dräger Fumigation Test Set Dräger-Tubes

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

Optoelectronics, Inc. Xplorer Serial Interface Specification. Interface Version 3.0

OPERATION MANUAL. Model : DC-190 TERAOKA SEIKO CO., LTD. Edition Month Year October 1998

LEWA EcoPrime Twin LPLC

Automated Hematology Analyzer. Small Footprint. Big Difference.

( ppm ) ( ppm ) ( ppm ) History :46:43

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

Models TJ30K TJ15K TJ6K TJ3K. Resolution Ratio 1g 0.5g 0.2g 0.1g Calibration graduation 10d 10d 10d 10d

Flue Gas Analysing System

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter

Transcription:

Technical Compendium CDI Blood Parameter Monitoring System 500

Technical Compendium CDI Blood Parameter Monitoring System 500 CDI Blood Parameter Monitoring System 500 System Overview The CDI System 500 consists of a monitor to process and display data, a user-selected combination of blood parameter modules (BPMs) and a hematocrit/oxygen saturation probe (H/S probe), disposable sterile sensors and H/S cuvette, and a calibrator. The disposable sensors and H/S cuvette are installed in the corresponding cable heads at a point in the circuit which will allow adequate exposure to blood (see Figure 1). Users select the combination of BPMs and H/S probe depending on the parameters to be monitored (see Table 1). BPMs, which measure arterial or venous ph, pco 2, and K +, use optical fluorescence technology in conjunction with the disposable CDI System 500 shunt sensor. The H/S probe, which measures hematocrit, hemoglobin and oxygen saturation, uses optical reflectance technology in conjunction with the disposable H/S cuvette. Figure 1: Components of the CDI System 500. Parameters Measured Components Technology Utilized Arterial, ph, pco 2, and K + Arterial BPM with shunt sensor Optical fluorescence Venous, ph, pco 2, and K + Venous BPM with shunt sensor Optical fluorescence Hct, Hgb, O 2 saturation H/S probe with H/S cuvette Optical reflectance Table 1: Component configurations of the CDI System 500.

Optical Fluorescence with the CDI Shunt Sensor The CDI System 500 uses optical fluorescence technology with the shunt sensor to measure ph, pco 2, and K + in blood. The shunt sensor contains four microsensors one each for ph, pco 2, and K + and a thermistor to measure temperature. The microsensors are in direct contact with the blood, enabling rapid response time. The CDI System 500 shunt sensor can be placed in any arterial or venous shunt or purge line with continuous flow (see Figure 2). A minimum blood flow requirement of 35 ml/min is necessary for proper measurement. During normal operation of the CDI System 500, light emitting diodes (LEDs) in the cable heads direct light pulses toward the microsensors, which contain fluorescent dyes (see Figure 3). As these pulses strike the microsensors, fluorescent light is emitted. The intensity of the fluorescent light will vary depending on the ph, pco 2, and K + in the blood. A photo detector in the cable head measures the intensity of the fluorescent light and converts it to numerical data which is displayed on the monitor screen. Optical Reflectance with the CDI H/S Cuvette The CDI System 500 uses optical reflectance technology with the H/S probe to measure total hemoglobin and percent oxyhemoglobin, which exhibit different absorbance and reflectance characteristics at different wavelengths. The flow-through H/S cuvette is installed directly in the tubing circuit. A window in the cuvette allows optical measurement without blood contact (see Figure 1). LEDs in the H/S probe direct light pulses of specific wavelength at the blood through the optical window in the H/S cuvette (see Figure 4). The absorbance characteristics of hemoglobin and oxyhemoglobin can be measured by the photodetector in the H/S probe. Hemoglobin and oxyhemoglobin measurements are taken every 18 milliseconds. The output of the detector is converted to numerical data which is displayed on the monitor s screen. The ph, pco 2, and measurements are taken every second. The K + measurement is taken every six seconds. Figure 4: Optical reflectance: CDI H/S cuvette and probe. Cuvette Blood Flow Rates The CDI System 500 should only be used where there is blood flow through the extracorporeal circuit. To perform accurately, the H/S cuvette requires blood flow rates shown in Table 3. Figure 3: Optical fluorescence: CDl System 500 shunt sensor and BPM cable head. H/S Cuvette Connector Size Min Flow Max Flow 1/2 1.0 LPM 7.0 LPM 3/8 0.5 LPM 4.0 LPM 1/4 0.2 LPM 1.5 LPM Table 3: Restoration of blood flow above the minimum through the H/S cuvette will restore performance of the system.

Technical Compendium CDI Blood Parameter Monitoring System 500 CDI 500 Blood Parameter Monitoring System Calibration of the Microsensors To perform the calibration, the system measures the fluorescent intensities emitted by a microsensor as it is exposed to Gas A and then Gas B. It then plots these two fluorescent measurements as a function of the predefined values of the calibration gases (see example for in Figure 5). The system uses the two points to create a slope and a y-intercept for that parameter. During bypass, as the system measures the fluorescent intensity of the blood in the extracorporeal circuit, it uses the slope and intercept to extrapolate corresponding blood parameter values. Y-intercept ph, pco 2 Sensors Sensors for ph, pco 2, and are calibrated using a two-point tonometered calibration system, similar to the system used to calibrate the electrodes in laboratory analyzers. Measured Flourescent Intensity Gas B Value (25.7) Slope Gas A Value (176.4) The calibration process uses the CDI Calibrator 540 and two canisters of calibration gases, Gas A and Gas B. The calibration gases contain precise, defined levels of pco 2 and gases (see Table 4). During calibration, the shunt sensors (attached to the BPM cable heads) are placed in the calibrator, allowing the calibration gases to flow through the buffer solution contained in each shunt sensor. This exposes the microsensors to the gases with known pco 2 and values. A predefined ph value for each calibration gas is determined by the interaction of the known pco 2 level in the calibration gas with the buffer solution. Gas A (Model CDI506) Gas B (Model CDI507) ph 7.234 ph units 7.611 ph units pco 2 7.5% ±0.1% (48.1 mm Hg) 27.5% ±0.1% (176.4 mm Hg) 2.8% ±0.1% (18.0 mm Hg) 4.0% ±0.1% (25.7 mm Hg) Table 4: Calibrating gas values for the CDI System 500. Balance of gas mixture is nitrogen (N2). Gases measured at 1 atm and 21 C. Blood Parameter Value (mmhg) Figure 5: Example of a 2-point calibration for sensor. K + Sensor Calibration of the K + microsensor also relies on a twopoint slope and intercept calibration process. The slope is defined using the factory-measured value encoded in the calibration code entered from the sensor pouch during the initial calibration sequence (as described in the Operator s Manual). The intercept point is obtained after the initiation of bypass using the K + level in a patient blood sample: the sample is drawn; the CDI System 500 K + reading is stored in the system; the sample is processed using the laboratory analyzer; the analyzer s value is then entered into the CDI System 500 to recalibrate the stored reading. H/S Probe Each H/S probe is precalibrated at the factory for oxygen saturation, hematocrit, and hemoglobin values; and further calibration is not required before going on bypass. To meet system accuracy limits, perform an in vivo calibration as outlined in the Instructions For Use. www.terumo-cvgroup.com

Technical Compendium CDI Blood Parameter Monitoring System 500 CDI System 500 Measures or Calculates 11 Critical Blood Parameters The CDI Blood Parameter Monitoring System 500 (CDI System 500) was designed and developed to enable continuous monitoring of in-line blood parameters ph, pco 2, potassium (K + ), oxygen saturation, hematocrit, hemoglobin, and temperature during cardiopulmonary bypass (CPB). Using optical fluorescence and reflectance technologies and disposable sensors placed in the extracorporeal circuit, the CDI System 500 monitors and displays real-time changes in blood parameters. The system provides continuous results and also eliminates the need to consume or dispose of blood samples, as is required in laboratory analyzers. Figure 2: The CDI System 500 shunt sensors and cuvette are placed in the extracorporeal circuit allowing real-time response to changes in blood parameters. System Accuracy Limits The CDI System 500 has been subjected to rigorous bench tests to simulate the clinical use of the device and assessed for accuracy and precision over the system operating ranges of the measured parameters. Blood samples taken from the test circuit were analyzed in conventional analyzers, and these results were compared (on a sample-by-sample basis) to analyses provided by the CDI System 500. Table 2 shows the mean difference between the two measurement techniques, and the standard deviation of the differences found. Mean Standard ph Sensor -0.018 0.023 pco 2 Sensor -0.2 2.2 Sensor Arterial (>80 mm Hg) Sensor Venous (<80 mm Hg) 6.1 17.6 1.3 2.3 Oxygen Saturation Value -0.4 1.6 Temperature -0.07 0.22 Total Hemoglobin Value -0.09 0.38 Potassium Sensor -0.06 0.19 Hematocrit Value -0.4 1.2 Table 2: Mean measurement technique and standard deviation differences found. www.terumo-cvgroup.com

Product Specifications Displayed Parameters System Operating Ranges System Display Ranges ph 6.8 to 7.8 ph units 6.5 to 8.5 units pco 2 10 to 80 mm Hg (1.3 to 10.7 kpa) 20 to 500 mm Hg (2.7 to 66.7 kpa) 10 to 200 mm Hg (1.3 to 26.7 kpa) 10 to 700 mm Hg (1.3 to 93.3 kpa) K + 3.0 to 8.0 mmol/l 1.0 to 9.9 mmol/l Temperature (T) 15 to 40 C 1 to 45 C Oxygen saturation (SO 2 ) 60 to 100% 35 to 100% Hematocrit (Hct) (15 < T <40 C) 17 to 38% 12 to 45% Total hemoglobin (Hgb) 5.6 to 12.6 g/dl 4.0 to 15.0 g/dl Oxygen consumption (VO 2 ) 10 to 400 ml/min 10 to 400 ml/min Base Excess (BE) -25 to 25 meq/l -25 to 25 meq/l Bicarbonate (HCO 3 ) 0 to 50 meq/l 0 to 50 meq/l Blood flow (Q) 0 to 9.9 L/min 6.5 to 8.5 units Serial Data Output The CDI System 500 has a serial data output port, which allows use with an external serial printer, computer, or data acquisition system. When the CDI System 500 is attached to an external device, users can send patient data (blood parameter values over the course of an operation) from the CDI System to this device. A second serial interface port, called the pump interface, allows the CDI System 500 to receive flow (Q) data from selected pumps. These are the Terumo Advanced Perfusion System 1, Sarns Modular Perfusion System 8000 and 9000, Sarns Centrifugal Pump, Sorin S3, Sorin SC, Medtronic BioMedicus 550 Centrifugal Pump, and the Maquet HL20. When using the pump interface port with the Terumo Advanced Perfusion System 1, data can also be sent from the CDI System 500, to display blood parameter values on the Central Control Monitor. Note: In order to meet the System Accuracy Limits, the monitor should be used within the above System Operating Ranges. Values outside of these ranges will be displayed and an alert will be triggered. The System Display Ranges are defined in the chart above. Output Type Data Bits ASCII Output, Sarns 9000 or Packet Mode (if Sarns 9000 is selected, all other values on the screen become unchangeable). 8 data/1 stop or 7 data/2 stop Product Specification Size (H x W x D) Weight Monitor 11 x 12.5 x 6 16.1 lb. Parity none, even, or odd Baud Rate 1200, 2400, 4800, 9600, 19200, or 38400 Calibrator 12.5 x 8 x 8 8.4 lb. Output Interval 0, 0.1, 0.5 minutes, or 1-10 minutes ( 0 means the CDI System 500 will send data on demand only). Monitor Power Requirements and Specifications 100-240 VAC, 50/60 Hz 12 volt backup battery Data Output Port: RS-232 serial interface Pumping Systems Input Port: RS-232/RS-485 serial interface Model CDI510H Shunt Sensor Sterile, heparin-treated Priming volume 1.2 ml System Display Update Every six seconds System Measurement Cycle Time ph, pco 2 = one measurement per second K + = one measurement per six seconds SO 2, Hct, Hgb = one measurement per eighteen milliseconds H/S Cuvette Sterile Priming volume for # 6914 (1/4 x 1/4 ) = 4 ml Priming volume for # 6913 (3/8 x 3/8 ) = 9 ml Priming volume for # 6912 (1/2 x 1/2 ) = 16 ml For information on Terumo Cardiovascular Group products: Terumo Cardiovascular Group 6200 Jackson Road Ann Arbor, MI 48103-9300 USA Tel: +1.734.663.4145 Fax: +1.734.663.7981 www.terumo-cvgroup.com Terumo Corporation 44-1, 2-chome, Hatagaya Shibuya-Ku, Tokyo 151-0072 Japan Tel: +81.3.3374.8111 Fax: +81.3.3374.8399 www.terumo.co.jp Terumo Europe N.V. Authorized EC Representative Interleuvenlaan 40, 3001 Leuven Belgium Tel: +32.16.38.12.11 Fax: +32.16.40.02.49 www.terumo-europe.com Terumo Europe N.V. Cardiovascular Division Ludwig-Erhard-Strasse 6 65760 Eschborn Germany Tel: +49.6196.8023.0 Fax: +49.6196.8023.555 Terumo Latin America Corporation 8750 NW 36th Street, Suite 600 Miami, FL 33178 USA Tel: +1.305.477.4822 Fax: +1.305.477.4872 Terumo Corporation Dubai Branch Al Masraf Tower, 22nd Floor P.O. Box 20291, Dubai UAE Tel: +971.4.2212220 Fax: +971.4.2213330 Terumo India Pvt. Ltd. Unit No. 1601 & 1602 Tower B 16th Floor, Unitech Cyber Park Sector-39 Gurgaon, Haryana 122001 India Tel: +91.124.4718700 Fax: +91.124.4718718 Terumo Asia Holdings Pte. Ltd. 300 Beach Road #33-03 The Concourse 199555 Singapore Tel: +65.6.295.1792 Fax: +65.6.294.2329 Terumo is a registered trademark of Terumo Corporation. CDI is a registered trademark of Terumo Cardiovascular Systems Corporation. 2016 Terumo Cardiovascular Systems Corporation. January 2016. 869407