CROSS TRAINING PROGRAM DESCRIPTION, GOALS AND OBJECTIVES

Similar documents
TABLE OF CONTENTS FLORIDA BUILDING, BUILDING

0103 Plan Reading 4% Read plans to verify the project conforms with the code, approved plans, and construction documents.

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3%

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS Section 201 General Definitions... 15

City of South Pasadena COMMUNITY IMPROVEMENT

CITY OF CRANSTON RESIDENTIAL PERMIT PROCEDURE BASEMENT RENOVATION

* RESIDENTIAL PLAN REVIEW *

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)

Fill out all sections or mark with N/A (not applicable)

COMMERCIAL PROJECT INFORMATION

INTERNATIONAL CODE INTERPRETATIONS

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

Fill out all sections or mark with N/A (not applicable)

UCC Permit Application Procedures

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

City of Pekin- Zoning and Inspections Department 111 S. Capitol Street, Pekin, Illinois (309)

Township Of Blandford-Blenheim Permit Guide

BUILDING A NEW HOME. Construction Permit Tips For Home Owners

PLANS REVIEW CRITERIA - COMMERCIAL BUILDINGS

Submission, Review and Approval of Construction Documents Submission and Review of a Completed Application for Permit

SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE Information and Required Forms for Structures in Flood Zones AE & VE

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

SECTION 1524 (FLORIDA BUILDING CODE) HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

CONSTRUCTION GUIDELINES

Residential Building Inspections

PERMIT APPLICATION REQUIREMENTS INTERIOR RENOVATIONS/BUILD OUTS CODES USED: ADOPTED FLORIDA BUILDING CODE & NEC

City Of Mendota Construction Procedures

UCC CONSTRUCTION PERMIT APPLICATION INSTRUCTIONS

BUILDING CODES & DESIGN CRITERIA

Received by:* Date Received:* Zoning Approval:* Date:* PERMIT#:* *ZONING: *SETBACKS: FRONT ft/ SIDE ft/ REAR ft *FLOOD ZONE:

f. Sign Installer/Hanger must submit the following to qualify for a license: i. Certificate of Insurance 1. $300,000 Minimum Liability Coverage

Rebuilding your Home after the storm? Adding on, renovating, or remodeling your home? Here's information YOU need to know about the 50% Rule.

CITY OF CALABASAS RESIDENTIAL PLAN REQUIREMENTS 1 OF 5 8/2017 PLAN INFORMATION

TOWN OF ROTTERDAM BUILDING DEPARTMENT RESIDENTIAL ACCESSORY BUILDINGS AND STRUCTURE PERMIT APPLICATION Ext 395

PERMIT SUBMITTAL GUIDE FOR COMMERCIAL PROJECTS

INDIANA COUNTY Office of Planning and Development 801 Water Street Indiana, PA (724) Fax (724)

INSPECTION REQUIREMENTS Page 1 of 5. JOB SITE ADDRESS posted during entire construction process.

Change of Coordinating Registered Professional (CRP) or Registered Professional (RP)

E d u c a t i o n a l S e m i n a r s f o r B u i l d i n g & R e s i d e n t i a l C o d e

HARPER WOODS BUILDING DEPARTMENT PROCEDURES FOR OBTAINING CERTIFICATE OF OCCUPANCY

APPLICATION AND CERTIFICATE FOR PAYMENT

Tohono O odham Nation. Adoption of Building Codes

Description of Work: Cost: $

Town of Fredonia. 25 N Main St. * PO Box 217 Fredonia AZ Fax: * Office

SUBMITTAL REQUIREMENTS FOR SINGLE FAMILY DWELLINGS

CITY OF GLEN COVE Building Department

Administrative Changes

Osceola County Growth Management Division 1 Courthouse Square, Suite 1400 Kissimmee, FL

NEWS LETTER MARCH 27, 2009

City of Oviedo Residential Permit Application Guidelines

COMMERCIAL SUBMITTAL PACKET

DAG Architects, Inc. July South Walton Fire District Fleet Maintenance/Logistics Building & Training Tower

PERMIT APPLICATION REQUIREMENTS NEW SINGLE FAMILY DWELLING

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

Huntington Building Inspection

RESIDENTIAL BUILDING PERMIT GUIDE FOR MULTI-FAMILY DWELLINGS

BASEMENT FINISH CONSTRUCTION

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

B. RESIDENTIAL MASTER PLUMBER $ $ $

TOWN OF GREENVILLE APPLICATION FOR PERMIT

1. Complete Building Permit Application forms on page 2. Include septic system design approval from the Washington County Health Department.

ONE AND TWO FAMILY DWELLING PERMIT APPLICATION REQUIREMENTS

Building Permit Application Checklist

Note #2: Refer to Commercial Permitting Handbook 2016 Denver Building and Fire Code for asbestos regulations.

Greene County Department of Building Regulation Residential Permit, Plan Approval, & Inspection Process

PERMIT APPLICATION CHECKLIST Municipal Address, Phone & Fax NONRESIDENTIAL

Town of Pawling Residential Building Permit Application

Plan Submittal Checklist 2015 I-Codes

COMMERCIAL TENANT IMPROVEMENT PERMIT APPLICATION

Florida Building Code 6th Edition (2017) High-Velocity Hurricane Zone Uniform Permit Application Form

REPORT CHECKLIST SUPPLEMENT

TENANT IMPROVEMENTS GUIDE

UNIFORM CONSTRUCTION CODE (UCC) BUILDING PERMIT APPLICATION RESIDENTIAL NEW CONSTRUCTION AND/OR IMPROVEMENTS

Commercial Remodel Permit

International Code INTERPRETATIONS

CONSTRUCTION DOCUMENTS CHECKLIST for the 2012 Michigan Building Code Including Building Permit Application Checklist

COMMERCIAL BUILDING PERMIT

RESIDENTIAL MANUFACTURED HOMES NOT FOR HUD HOMES

Course Information. Title: Modular Building Foundations Advanced Module

City of Roanoke. Commercial Permit Submittal Guidelines

Training Certification Categories

CHAPTER 6 BUILDING REGULATIONS ARTICLE I - BUILDING CODES

FLORIDA BUILDING CODE

PICKENS COUNTY BUILDING CODES SPECIAL INSPECTION PROCEDURE IBC CHAPTER EDITION

COMMERCIAL PLAN SUBMITTAL GUIDELINES JAN 2018

TOWN OF PORT ROYAL BUILDING CODES DEPARTMENT Building Permit Submittal Requirements

PERMIT APPLICATION REQUIREMENTS NEW COMMERCIAL BUILDING/CONSTRUCTION CODES USED: CURRENT ADOPTED FLORIDA BUILDING CODE AND NEC

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

Code Compliance Research Report CCRR-0187

UNIFORM CONSTRUCTION CODE (UCC) BUILDING PERMIT APPLICATION RESIDENTIAL NEW CONSTRUCTION AND/OR IMPROVEMENTS

Code Compliance Research Report CCRR-0153

STATEMENT OF SPECIAL INSPECTION FORM

CONTRACTOR LICENSE APPLICATION Please complete each field; insert N/A if not applicable. Incomplete applications will not be processed.

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

Residential Plan Review for New One and Two Family Dwellings

4. Number of drawings required: ( ) Locations of nearest streets

Transcription:

CROSS TRAINING PROGRAM DESCRIPTION, GOALS AND OBJECTIVES Part I-B An original copy of this form must accompany every trade specific application for qualification in the program. GOAL The goal of the Building Officials Association of Florida Foundation/Cross Training Program is to provide an acceptable, practical alternative for the experience requirement for examination qualification pursuant to 468.609(2)(4), F.S. OBJECTIVES The Certification Committee of the Building Officials Association of Florida has been established and is operated in order to gain recognition and approval by the Building Code Administrators and Inspectors Board (BCAIB) of training developed and administered by the BOAF, in conjunction with appropriate field training monitored and certified by currently licensed and knowledgeable individuals in the trade desired under the supervision and tutelage of a standard licensed Building Code Administrator (BCA, aka Building Official). Such training program will provide for practical training and qualification through relevant, recognized classroom education and on-the-job training (OJT) consistent with the original goals of the BCAIB when proposing the statutory amendment (468.609 (2)(4) in 1998. This training program may allow agencies to utilize existing personnel resources as trainers while preparing other current employees for broader responsibilities and, at the same time, maintain accountability to the BCAIB. OUTLINE The BOAF Certification Committee has established training criteria for each inspector and plans examiner category, comprised of appropriate classroom education and OJT, for individuals seeking to improve their professional qualifications through BCAIB certification exams and meeting all other requirements of Florida Statute 468.609(2)(4). The Certification Committee recognizes the varying levels of complexity in each category and has established training requirements exceeding 200 hours, the statutory minimum. Classroom and OJT training for any category must be completed within the thirty-six (36) months immediately preceding the submittal date of an application to the BOAF Certification Committee. Training criteria consists of: Completion of BOAF, or equivalent approved preparatory coursework in the exam category sought. 1 Page Revised October 21, 2015

Field training (OJT), which must be under the supervision of and substantiated by a Trainer (an active, standard licensee in the appropriate specified category whose primary duty is practice in that category requested by the Trainee) with required documentation and preapproval by BOAF. The Trainer s supervising Building Official, properly licensed (must hold a standard BCA license) and designated as such, shall by application of his/her signature attest to said documentation. Submittal of a statement by that person properly licensed and designated as the Building Official (in the jurisdiction providing the OJT) indicating the applicant is reasonably qualified to take the BCAIB examination and assume responsibility for work in that category upon passing the exam. Submittal of an application with required documentation and any remaining portion of the application fee to the BOAF office for review and issuance of a certificate, upon approval, which must be submitted to the BCAIB as proof of experience in the requested area. Currently, $250 is required with the request for participation and $245 is required to be submitted with the completed application. The appropriate BOAF Certification Committee will review the application for compliance with these requirements, confirm the information contained therein, reject each insufficient submittal with written explanation, or approve and return it to the applicant for inclusion with his/her application to the BCAIB as proof of having met these requirements. The fee for re-submittal of an application rejected for any reason is $100.00. Questions concerning the Cross Training Program should be addressed to: Cross Training Coordinator Building Officials Association of Florida 528 West Lake Mary Blvd. Sanford, Florida 32773 TRAINING@BOAF.NET 2 Page

CROSS TRAINING FAQ Frequently Asked Questions Part I-C Q. Do I need to fill in every line of the application? A. The application MUST be complete. If a section does not pertain to you, notate it with N/A or not applicable, or another identifier to indicate it was not inadvertently overlooked. Q. I did not have trade specific training on each and every item on the training checklist. Does this mean my application will be rejected? A. No. We have tried to place important items related to each trade on this sheet. While your experience should be diverse and varied, having experience on every item noted on the sheet may not be required. As a general rule, a minimum of 75% of each section should be covered in your training, as a general rule. Covering all the areas of experience noted is better and some sections will require a greater time commitment to be 100% trained. If you did not receive training in a specific area, that does not automatically disqualify you. You can only state training in the areas which you actually receive it, as evidenced by your trainers affidavit. Q. How long does the review process take? A. The review process typically takes about 6 weeks from the time we receive it. At the conclusion of the review, you will receive a certificate or letter with the results in the mail. Q. Should I take the training class before or after my field training? A. There is no hard and fast rule for this. It is suggested you start your field training, then take the class. This will allow you to experience some of the specific items related to the trade you are training in and develop some questions that will be answered in your classroom training, allowing you to be more knowledgeable as you finish your field training. Q. Is there more than 1 piece to the application? A. Yes. Every application has 2 parts Part I, Name, employer, trainer(s) and Part II, the trade specific portion. Q. Do I need to use the most current edition of the application? A. Yes, check the BOAF website at www.boaf.net to ensure you have the most current editions of all of the forms. 1 Page Revised October 22, 2015

Q. Can I use my Inspector training for Plans Examiner? A. No. Inspections and plans examining are different. Classroom training may crossover, however, On the Job (OJT) or field training does not. Q. How and when do I take the required exam? A. There are a couple ways to take the exam. The first and quickest way to achieve licensure is to schedule the exam through the International Code Council at www.iccsafe.org and include your passing score sheet with your application. This will reduce your time to attain licensure by several weeks, or months. The next way is to complete your training and then submit an application to the BCAIB. Upon review and approval of your application, the Board will forward your information to ICC, who will in turn forward the information to the testing agency and send you a letter stating that you may then schedule the exam. Upon successful completion of the exam, you must then forward your successful completion letter to the Board. After further review, and matching up the paperwork, your endorsement will be issued. Q. Is there a difference in cost based on the time I take the exam? A. Yes. When you schedule the exam directly with ICC, you pay the entire cost. If you wait for the Board to approve you for the exam, you only pay a subsidized cost. You might consider the money saved by taking the subsidized exam versus the time delay in obtaining the endorsement. Q. Does my application need to be typewritten? A. No, just remember, if you can t read it, neither can we. This may cause delays or even return of your application. The important thing to keep in mind is that this training replaces the required 5 years of experience. Please be neat, complete and ensure the trade specific information requested is detailed on the forms. Q. Will my certificate be mailed to my house or my office? A. Unless identified differently on the application, we will mail the certificate to your residence. In many cases, mail is delayed at offices or even returned to us if your name, mail stop or other information is not recognized. In order to expedite delivery, we try to use the residence address provided on the application. Q. How do I know how many hours to spend in each trade for 1 & 2 Family Dwelling Inspector cross training? 2 Page Revised October 22, 2015

A. That is an interesting question. While an exact number is difficult to state, the applicant should spend the most time in their weakest areas. As a general guideline, if the following hours per trade are used, you would have spent adequate time in each trade discipline. The trainer should determine the trade hours based on your experience level. Building 135 hrs. Electrical 135 hrs. Mechanical 90 hrs. Plumbing 90 hrs. Remember, in any case, the total training hours cannot be less than 450 hours! Q. I already hold a standard license, are you saying I still need to train in that category when working toward a 1 & 2 Family Dwelling Inspector? A. Yes. Training to be a 1 & 2 family Dwelling Inspector requires you to refresh your standard trade. This is due to differences between commercial and residential work, a tendency to get used to doing things we have always done and also to ensure you are up to date on new technologies, methods and code requirements. Q. I noticed when filling out the trade specific OJT Checklist, there are items on the list that are not present in the jurisdiction where I work. Am I still expected to get trained on them? A. Not necessarily. Your Trainer can only fill in the area for the items on which you have been trained. Keep in mind, this program uses your past experiences and applies this additional training to replace the normally required 5 years of hands on experience that satisfies one of the experience criteria. Most people will not have the opportunity to experience every facet of every trade under every condition. As a rule of thumb, your experience should expose you to at least 75% of the items contained on the OJT Checklist. Be honest and forthright regarding your training. The Committee evaluates every application on its own merits and reviews your documentation as a standalone application. Q. Can I train in a larger, more diversified jurisdiction? A. Yes. Remember, training is what is important. If the community you work in has limited construction projects and/or limited personnel, you may be better served, and better able to serve your community, by getting training in a larger jurisdiction. Many municipalities have inter-local agreements with the County or other municipalities nearby that would allow for you to receive better or more diverse training opportunities. If you choose this option, always remember the standard licensed Building Official under which the trainers work is required to sign the training affidavit of trainers. Q. I am training for the 1&2 Family Dwelling Inspector, my trainer has all 4 standard certificates, can he/she sign off on my training for 1 & 2 Family Dwelling Inspector? A. No. The trainer for a 1 & 2 Family Dwelling Inspector cross training certificate is required to have a standard 1 & 2 Family Dwelling certificate. This is a requirement of the program. 3 Page

Q. What do I send to the BCAIB at the State? A. A copy of the letter and the certificate you receive for the completion of the program, along with your completed BCAIB application and associated fees. Q. Is the Cross Training program for both residential and commercial inspectors? A. When you have completed your Cross Training you will have been exposed to both commercial and residential code applications. While a standard license will allow you to inspect/review both types of applications it does not qualify you for a 1&2 Family license in the State of Florida. Additional training is required. 4 Page

Building Officials Association of Florida Cross Training Pre-Participation Registration Application This certificate and one-half (1/2) of the required fee, currently $250 of the $495 fee, must be submitted to and approved by BOAF prior to starting cross training. The remainder $245 of the total $495 will be due with your completed application. An approved, dated copy of this certificate will be returned to you as proof of enrollment in the program. Please be sure to read all of the information related to this program prior to your submission. All rules and instructions are posted on the BOAF website, cross training page. As these are subject to change on occasion, we suggest you refer to the web pages during your training to stay abreast of any changes that may occur. You will have three (3) years from the approval date to complete both the field and classroom training related to this approval. (Name of jurisdiction/firm) desires to start the training of License # (Full name of trainee) (DBPR) Select (1) desired category below for this application. A maximum of (2) applications are allowed to be active in this program. Minimum Hours required: Field *Classroom Building Inspector 250 35 Building Plans Examiner 250 85 Electrical Inspector 250 34 Electrical Plans Examiner 250 34 Mechanical Inspector 182 28 Mechanical Plans Examiner 182 28 Plumbing Inspector 182 28 Plumbing Plans Examiner 182 28 1 & 2 Family Dwelling Inspector 450 Varies BCAIB Licenses Currently Held and Endorsements: BN ( ) Building ( ) Electrical ( ) Mechanical ( ) Plumbing ( ) 1&2 Family Dwelling PX ( ) Building ( ) Electrical ( ) Mechanical ( ) Plumbing ( ) 1&2 Family Dwelling BU SFP Other 1 Page Revised October 20, 2015

*Your Application Number will remain with this certificate through completion. By our signatures below, we certify we have read the rules and instructions for the BOAF cross training program and agree to abide them. We understand the standard licensed Building Official signing this form is responsible to monitor the training, performed by a standard licensed certificate holder in the category sought of the standard licensed trainee shown here. The time spent on training as documented by the OJT forms will be field training and no classroom training, accept as pre-approved by BOAF will count toward the required time. Training will be documented to the nearest quarter hour and verified by the Building Official. Training time is to be appropriate to the category sought and those areas specified on the training checklists should be stressed. Additional training is permitted as well to ensure complete knowledge and understanding of the category sought. By Request for approval for Field Training, I certify that I have read and understand the BOAF Cross Training Program Application and that all Field training (OJT), must be under the supervision of and substantiated by a Trainer (an active, standard licensee in the appropriate specified category whose primary duty is practice in that category requested by the Trainee) and approved by the Building Official (BCA) of the Authority Having Jurisdiction. Anticipated Trainers: Standard License # Endorsement Date for Requested Discipline Building Official Signature BO Standard License (BU) # Date Issued Building Official Printed Name Trainee Signature Standard License # Date of License Issuance Trainee Printed Name BOAF Member # 2 Page Revised October 20, 2015

E-Mail (Required) @ Trainee Personal Data: Home Address City State Zip Code Home Cell Phone Work Employer Information: Name of Employer Business Address City State Zip Code Fax Do not write below this line - BOAF Office Use Only Date Approved Authorizing Signature Date Paid Approved Through Comments: 3 Page

CROSS TRAINING BUILDING PLANS EXAMINER OJT CHECKLIST BCAIB Provider # 0001001 Training Program # 6559 Part II-D ONLY THE CURRENT EDITION OF THE BOAF OJT CHECKLIST WILL BE ACCEPTED Please check the website at www.boaf.net to be sure you are submitting the most current edition of the applicable form. Each form becomes effective on the revision date contained on the form. Training completed prior to that date may be submitted on the previous form. This training program requires 85 hours (minimum) of classroom training as approved by BOAF. Classes are as follows: Building Principles and Code Application 35 hours Building Plans Examiner Class 50 hours This training program also requires 250 hours (minimum) of properly documented On the Job Training (OJT) with a Florida Standard Licensed Building Plans Examiner Trainer as evidenced by this and other required forms, including the notarized trainers affidavit. A. Extensive training on all aspects of building systems should include both residential and commercial sections of the code as scripted by the following: 1. Administration 2. Occupancy Classification 3. Special Occupancy 4. General Building Limitations 5. Construction Types 6. Fire Resistant Materials 7. Interior Finishes 8. Fire Protection Systems 9. Means of Egress 10. Florida Accessibility Code for Building Construction 11. Housing Accessibility Guidelines 12. Interior Environment 13. Energy Efficiency 14. Exterior Wall Covering 15. Roofs & Roof Structures 16. Structural Loads 17. Foundations/Retaining Walls 18. Concrete 19. Light Metal Alloys 20. Masonry 21. Steel 22. Wood 23. Glass & Glazing 24. Gypsum Board & Plaster 25. Plastic 26. Electrical systems 27. Mechanical Systems 28. Plumbing Systems 29. Elevators & Conveying Systems 30. Special Construction 31. Construction in the Public R/W 32. Site Work, Demolition/Construction 33. Existing Buildings 34. Private Swimming Pools B. Trainees must mark each item trained on, and initial in the spaces provided on the OJT checklist, when each training segment has been completed. C. Trainees must also include the number of specific areas and the total hours spent during OJT. 1 Page Revised October 21, 2015

BUILDING PLAN REVIEW OJT CHECKLIST My specific On the Job Training (OJT) has included instruction on the following items as indicated by X Building Trade Plan Review: High Velocity Zone Height & Area Mixed Types of Construction Combustibles in Fire Rated Assemblies Restrictions on Interior Finishes Fire Alarms Stairway Protection Exit Discharge Ramps Egress by Occupancy Rodent Proofing Fire Dept. Access in Exterior Walls Roof Coverings Dead Loads Load Combinations Load & Deflection Waterproofing & Damp proofing Formwork, Embedded Pipes & Construction Masonry Steel Vertical Framing Impact, Wind & Other Loads Allowable Partition Heights Elevators Tents for Public Assembly Site Work, Demolition & Construction Occupancies Buildings on Same Lot Materials for Fire Resistance Combustibles in Concealed Spaces Acoustical Ceiling Systems Occupant Load & Means of Egress Stairway Construction Fire Escapes Balconies, Porches & Galleries Florida Accessibility Code for Construction Florida Energy Efficiency Code Roof Weather Protection Roof Insulation Live Loads Deflections Evacuations Retaining Walls Details of Reinforcement Special Occupancies Construction Types Fire Resistant Separations Thermal Insulating Materials Fire Sprinklers Arrangement & Number of Exits Access to Roof Doors Guardrails Light & Ventilation Veneered Walls Roof Fire Classification Reroofing Wind Loads Minimum Uniformly Distributed Live Loads Footing & Foundations Termite Protection Slab on Ground Masonry Chimneys Fastenings Wood Structural Panel Diaphragms Sloped Glazing Foam Plastic Insulation Covered & Enclosed Walkways & Tunnels Marquees, Canopies or Fixed Awnings Radon-Resistant Construction Swimming Pools Partitions Protection of Openings Calculated Fire Resistance Standpipes Special Exit Requirements Horizontal Exits Delayed Egress Locks Egress Illumination & Signs Sanitation Architectural Trim, Balconies & Bay Windows Materials Rooftop Structures & Components Special Loads Allowable Loads & Stresses Piles Concrete Quality Structural Aluminum 2 Page

Glass Block Walls Wood Roof & Ceiling Framing Glass Supports Vertical Gypsum Board Diaphragms Manlifts Canopies on Exterior Walls Existing Buildings Masonry Fireplaces & Barbecues Floor Framing Glass & Glazing Labeling Gypsum Board & Plaster Materials Light-Transmitting Plastics Membrane Structures Other Projections Rehabilitating Historic Buildings Total Hours OJT Training Received = hours Trainee and Trainer(s) should sign this form after all of OJT Training has been completed. Include all Trainers that have trained on the hours shown on the Checklist. By affixing our signatures and BCAIB (BN/PX) numbers below, we affirm and attest the above specific areas and hours of Building Plan Review Training have been successfully completed. / / Trainee BCAIB# Date Completed / / Building Plan Review Trainer BCAIB# Date Completed / / Building Plan Review Trainer BCAIB# Date Completed / / Building Plan Review Trainer BCAIB# Date Completed / / Building Plan Review Trainer BCAIB# Date Completed 3 Page

4 Page

BOAF CROSS TRAINING APPLICATION Part II-A Please print or type Applicant: Name DOB / / Home Address City State Zip Code Home Phone ( ) Cell Phone ( ) Office Phone ( ) Employer Email Address City State Zip Code Fax ( ) Date of Pre-Registration Approval by BOAF Office: / / Number BCAIB Licenses Currently Held and Endorsements: BN ( ) Building ( ) Electrical ( ) Mechanical ( ) Plumbing ( ) 1&2 Family Dwelling PX ( ) Building ( ) Electrical ( ) Mechanical ( ) Plumbing ( ) 1&2 Family Dwelling BU SFP Other Please identify the NEW certification category and specific trade you are seeking: ( ) Inspector: ( ) Building ( ) Electrical ( ) Mechanical ( ) Plumbing ( ) 1&2 Family Dwelling ( ) Plans Examiner: ( ) Building ( ) Electrical ( ) Mechanical ( ) Plumbing Explanation of Field Training: Start Date: / / Date Finished: / / Percentage of Commercial % Residential % Training Experienced 1 Page Revised October 21, 2015

CLASSROOM TRAINING REQUIREMENTS Certificates of satisfactory completion of BCAIB approved classroom training in the certification category applied for, equivalent in content and hours to the ICC courses listed below, must be included with your completed application. For courses other than the ICC courses shown, course outlines must accompany the certificates to confirm equivalency. Building Inspector Building Principles and Code Application 35 hours Laws and Rules Governing Building Inspection, Plan Review and Operations of the Building Department 40 hours Building Plans Examiner Building Principles and Code Application 35 hours Building Plans Examiner Class 50 hours Laws and Rules Governing Building Inspection, Plan Review and Operations of the Building Department 40 hours Electrical Inspector or Plans Examiner Electrical Principles and Code Application 34 hours Laws and Rules Governing Building Inspection, Plan Review and Operations of the Building Department 40 hours Mechanical Inspector or Plans Examiner Mechanical Principles and Code Application 21 hours Fuel Gas Principles and Code Application 7 hours Laws and Rules Governing Building Inspection, Plan Review and Operations of the Building Department 40 hours Plumbing Inspector or Plans Examiner Plumbing Principles and Code Application 21 hours Fuel Gas Principles and Code Application 7 hours Laws and Rules Governing Building Inspection, Plan Review and Operations of the Building Department 40 hours 1 & 2 Family Dwelling Inspector Building Principles and Code Application 35 hours Electrical Principles and Code Application 34 hours Fuel Gas Principles and Code Application 7 hours Mechanical Principles and Code Application 21 hours Plumbing Principles and Code Application 21 hours Laws and Rules Governing Building Inspection, Plan Review and Operations of the Building Department 40 hours Photocopies of certificates for completion of these approved courses must be attached to this application. Both the required classroom training and corresponding on the job training must be completed within the thirty-six (36) months immediately preceding the submittal date of this application. 2 Page

BOAF Building Official Training Affidavit Part II-G This form must be included in the foundation/cross training application package. Every Building Official overseeing training must sign and have notarized an individual affidavit which includes their name and the name of the trainee for each trainee under their supervision. I,, (Printed or Typed Name of Building Official) affirm, under penalty of perjury, that I physically and professionally oversaw the training received by the trainee named hereon under my authority. (Printed or Typed Name of Trainee) hereafter referred to as trainee, and certify him / her to be competent and knowledgeable in the areas in which he/she was trained by me in those areas as indicated on the associated OJT Training Report(s) and Checklist. Additionally, I understand the future potential possibility of charges being filed against me as a result of any investigations concerning the competency of the trainee related to the training received and further certify that as of this date, I understand and abide by the Code of Ethics as adopted by the Building Officials Association of Florida. Building Official Signature BU # Printed Name Date / / SIGNATURE MUST BE NOTARIZED: Place notary information in this area as required by law: 1 Page Revised October 21, 2015

BOAF Trainers Affidavit Part II-G This form must be included in the foundation/cross training application package. Every Building and Fire Official overseeing training must sign and have notarized an individual affidavit with their name and the name of the trainee for each trainee under their supervision. I,, (Printed or Typed Name of Trainer) certify that I personally and professionally trained I,, (Printed or Typed Name of Trainee) to the best of my ability and believe him / her to be competent and knowledgeable in the areas that I have instructed him / her in as indicated on the associated OJT Training Report(s) and OJT Checklist. To the best of my knowledge, the training I provided under the direction of my Building Official meets or exceeds the requirements of the BOAF Cross Training Program as indicated on the associated training forms, checklists and logs in the area of inspector / plan review (fill in technical area and circle the appropriate category) Additionally, I state the training provided to the Trainee supports the BOAF Mission Statement and the training was provided in compliance with the BOAF Code of Ethics as adopted by the Building Officials Association of Florida. Trainer Signature BCAIB # Printed Name Date / / Total hours trained SIGNATURE MUST BE NOTARIZED: Place notary information in this area as required by law: 1 Page Revised October 21, 2015

Trainer Approval (must be signed for each training) Dates: From / / To / / Sheet Total Accumulative Total Page of The Building Officials Association of Florida Foundation/Cross Training Program Part II-E Revised 02/15/2015 Applicant Name & BN/PX # (Print) ON JOB TRAINING (OJT) REPORT Signature Date of Inspection Occupancy Classification (FBC) Trainer Name & BN/PX # (Print) Signature Inspection/Review - Be Specific Time Permit # or Address Provide description from Checklist, (Nearest Not Just Codes! Use as many rows as necessary 1/4 of an hour)