SECTION 3.0 SPECIFICATIONS FOR DRINKING WATER DISTRIBUTION SYSTEMS DESIGN

Similar documents
UNIFORM DESIGN AND CONSTRUCTION STANDARDS FOR EXTENDING WATER DISTRIBUTION SYSTEMS SECTION 2 DESIGN STANDARDS

Permit for Construction of an Extension to a JEA Drinking Water Distribution System and/or JEA Wastewater Collection/Transmission System

Ivins City Standard Specifications for Design and Construction Part 2 Engineering and Design Standards

SECTION 1.0 PROJECT REVIEW AND ACCEPTANCE PROCESS

SECTION I. (Sub-Section 3) Water Systems Design Standards. 3.1 General Plans Preparation 3-1

A.1 WATER SYSTEM PLAN SUBMITTAL PROCEDURES AND GENERAL REQUIREMENTS

CHAPTER 5 WATER SYSTEM DESIGN STANDARDS

APPENDIX B. WSSC Design Criteria for Water Distribution Systems

WATER MAIN EXTENSION DESIGN REQUIREMENTS

SECTION 4 - DESIGN STANDARDS FOR WATER DISTRIBUTION FACILITIES

SPECIFICATION : BORING AND JACKING

TABLE OF CONTENTS PART III MINIMUM DESIGN STANDARDS Section 115 WATER DISTRIBUTION SYSTEM GENERAL SIZING LINES 115.

REGULATIONS GOVERNING WATER SERVICE TO CUSTOMERS OF THE EAST BAY MUNICIPAL UTILITY DISTRICT SECTION 30 NONPOTABLE WATER SERVICE

1. Required Minimum Flow:

B. All new water mains and temporary pipelines shall be disinfected prior to connection to the District s existing system.

Wastewater Master Facility Report. (Project Name) (Project Basin Location)

OPERATING POLICY MANUAL

GENERAL INFORMATION AND REQUIREMENTS

Guidelines for Design of Potable Water Distribution Facilities In New Developments

Agreement For Proposed Development

Water, Wastewater and Reclaimed Water Technical Manual for Subdivision and Site Development

[THIS PAGE INTENTIONALLY LEFT BLANK]

CONDITIONS OF APPROVAL. ATWORTH COMMONS PRELIMINARY PLAT and PLANNED UNIT DEVELOPMENT PPU & PPL th Court SW

CHAPTER 4 MINIMUM DESIGN CRITERIA

COMMISSIONERS OF PUBLIC WORKS of the CITY OF CHARLESTON, SOUTH CAROLINA DEVELOPMENT POLICIES

Water, Sewer & Natural Gas Design Guidelines

SECTION 4 - DESIGN STANDARDS FOR WATER DISTRIBUTION FACILITIES

Town of Huntertown Lima Road * PO Box 95 * Huntertown, IN Phone (260) * * Fax (260)

Water, Wastewater and Reclaimed Water Design Guidelines

HARKERS ISLAND SANITARY DISTRICT AMENDMENT TO WATER SYSTEM MANAGEMENT PLAN

Section 5 - Planning Criteria. Section 5

Hydraulic Modeling, PUDs & Managing Water System Growth

SEWER SYSTEM DESIGN GUIDELINES

Section V WATER DISTRIBUTION SYSTEM DESIGN GUIDELINES

Wastewater Capital Projects Management Standard Construction Specification

SECTION WATER MAINS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA

Developer s Packet. For Developments Requiring Large Meters

ORDINANCE NO AN ORDINANCE OF THE COASTSIDE COUNTY WATER DISTRICT

4A General Information A. Concept... 1 B. Conditions... 1

Memorandum #9 [11/17, DRAFT #3] 1

Developer s Packet. Water Construction

201 S. Anaheim Blvd. Page No Anaheim, CA RULE NO. 16 SERVICE CONNECTIONS, METERS, AND CUSTOMERS FACILITIES

Engineering Standard Minimum Checklist

BONDING REQUIREMENTS AND PROCEDURES

CITY OF LA MARQUE, TEXAS CHAPTER 3 WATER SYSTEM DESIGN CRITERIA

Missouri American Water Cross Connection Control Program

EL DORADO IRRIGATION DISTRICT

PROPOSED CONSTRUCTION BUILDING CODES FOR TURF AND LANDSCAPE IRRIGATION SYSTEMS

SECTION WASTEWATER FORCE MAINS

ARTICLE X. CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION ORDINANCE*

Appendix A - Technical Specifications Engineering Services for the Ponte Vedra Blvd 6 CI WM Replacement Project

PENNSYLVANIA STANDARDS FOR RESIDENTIAL SITE DEVELOPMENT: APRIL 2007 CHAPTER 8: OTHER UTILITIES

WSSC CODE OF REGULATIONS 2019

RECYCLED WATER ON-SITE DESIGN AND CONSTRUCTION STANDARDS FOR NON-RESIDENTIAL SITES

Agreement For Proposed Development

%&&2^ Harlan L. Kelly, Jr., General Manager

APPENDIX B STANDARD CONSTRUCTION DRAWING NOTES

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

SECTION WASTEWATER FORCE MAINS

SECTION 400 WATER SUPPLY SYSTEMS

NOTICE OF INTENT TO USE THE GENERAL PERMIT FOR CONSTRUCTION OF WATER MAIN EXTENSIONS FOR PWSs

CHAPTER 8 WATER SUPPLY SYSTEM

CULINARY WATER SYSTEMS

CROSS CONNECTION CONTROL PROGRAM POLICY Adopted March, 1990 Revised October, 2006

SECTION 8 WATER SUPPLY SYSTEMS

GUIDELINE FOR PROVIDING WATER AND SEWER SERVICE TO DEVELOPER PROJECTS AND PUBLIC OR PRIVATE PROPERTIES

ORDINANCE NO WHEREAS, two hazardous liquid pipelines extend through the western portion of

Cross Connection Control Rules

[THIS PAGE INTENTIONALLY LEFT BLANK]

CITY OF PANAMA CITY BEACH Utilities Administration & Engineering Offices 116 South Arnold Road Panama City Beach, FL 32413

RULES AND REGULATIONS FOR WATER AND WASTEWATER SERVICE APPENDIX G BACKFLOW PREVENTION AND CROSS CONNECTION CONTROL (BPCCC) PROGRAM

CHEMUNG COUNTY SANITARY CODE ARTICLE V ONSITE WASTEWATER TREATMENT SYSTEMS (OWTS)

SECTION PUBLIC WATER SERVICE CONNECTIONS

CITY OF TAMPA WASTEWATER DEPARTMENT TECHNICAL STANDARDS GUIDELINE. FOR CONSTRUCTION OF WASTEWATER FACILITIES July 2014 Version 6

STANDARD CONSTRUCTION SPECIFICATIONS

DESIGN AND CONSTRUCTION STANDARDS FOR WATER AND WASTEWATER FACILITIES SOUTH ADAMS COUNTY WATER AND SANITATION DISTRICT

DIVISION 3. CROSS CONNECTION CONTROL* Sec Definitions.

FEE SCHEDULE 7 Water Development and Connection Fees Aurora Water (Platted Before January 1, 2017)

STORM WATER MANAGEMENT STANDARDS DRAFT

DESIGN STANDARDS AND SPECIFICATIONS

MINIMUM STANDARDS AND CONSTRUCTION SPECIFICATIONS FOR WATER AND WASTEWATER SYSTEMS PREFACE

Ordinances of the Plainview Water District Town of Oyster Bay, Nassau County, New York ARTICLE VII CONTROL OF BACKFLOW AND CROSS-CONNECTIONS

DECLARATION OF COVENANTS, CONDITIONS AND RESTRICTIONS RADIANT LAKE ESTATES SUPPLEMENTAL ARCHITECTURAL GUIDELINES ARTICLE I INTRODUCTION AND POLICY

SECTION IV DESIGN CRITERIA FOR RECYCLED WATER DISTRIBUTION SYSTEMS

PROCEDURES GUIDELINES AND DESIGN REQUIREMENTS

ETOWAH WATER AND SEWER AUTHORITY ENGINEERING & CONSTRUCTION DEPARTMENT OCTOBER 2016 DEVELOPMENT GUIDELINES FOR WATER MAINS & SANITARY SEWER SYSTEMS

VALLECITOS WATER DISTRICT SECTION POLYVINYL CHLORIDE (PVC) PRESSURE PIPE

SECTION WATER DISTRIBUTION SYSTEM

KUM & GO 300 SUBDIVISION THORNTON, COLORADO

JACKSON COUNTY WATER AND SEWERAGE AUTHORITY. Cross-Connection Control Program

DESIGN AND CONSTRUCTION STANDARDS CODE

ADOPTED REGULATION OF THE STATE ENVIRONMENTAL COMMISSION. LCB File No. R049-18

PERC-RITE DRIP DISPERSAL DESIGN SUBMITTAL American Manufacturing Company, Inc

Bay County Manual of Standards and Specifications for Wastewater and Water Construction

SECTION POLYVINYL CHLORIDE (PVC) WATERLINE

Procedures for Connecting to Central Sewer System

CURRENT NORTH LAS VEGAS ADDENDA

Nueces County Water Control and Improvement District #3

TOWN OF MIDDLETOWN, MD W-1 (05/99)

Chapter NONPOTABLE WATER DISTRIBUTION SYSTEM

Transcription:

3.1 GENERAL SECTION 3.0 SPECIFICATIONS FOR DRINKING WATER DISTRIBUTION SYSTEMS DESIGN 3.1.1 The following specifications cover the general design, review of plans and specifications, and acceptance of drinking (potable) water distribution systems, water main extensions, and all appurtenant items which are to be constructed by private enterprise and are to be owned and maintained by Hillsborough County. 3.1.2 The Public Utilities Department (PUD) Technical Specification 331001 Water Mains & Appurtenances shall provide additional clarification regarding design details, materials of construction, installation and acceptance requirements. If further clarification is needed, contact the Site Engineering Review Section of the Development Services Department (DSD) or the Utility Design Section of the PUD. 3.1.3 All improvements and modifications made to the Hillsborough County water system shall be done in accordance with plans approved by the Site Engineering Review Section of the DSD. Material, workmanship, and installation shall comply with PUD Technical Specification 331001. 3.1.4 All pipeline and appurtenance materials in contact with potable water must be NSF-61 certified. 3.2 PLANS PREPARATION 3.2.1 All water distribution systems, water main extensions, and all appurtenant items shall be designed in accordance with the applicable regulations of Hillsborough County, the Hillsborough County Department of Health, the Florida Department of Environmental Protection and the standards established herein. 3.2.2 Hillsborough County PUD shall own and maintain all portions of the water system up to and including the water meter. When a distribution main will serve existing or future developments beyond the borders of the proposed site, the County may request oversizing. If the County determines that a line needs to be Oversized, the procedures for sizing and reimbursement, as outlined in Appendix 3, shall be followed. The distribution system or any portion thereof, which is to become the property and sole responsibility of Hillsborough County PUD, shall be designed and constructed within a public right-of-way or easement which may be used for said purpose. The primary feed for the distribution system shall be routed within County road right-of-way. A secondary feed may be routed within a utility easement dedicated to the County (design exception). 3.2.3 The water distribution system or water main extension shall be designed and constructed in accordance with the requirements specified in PUD Technical Specification 331001. 3.3 PLANS REVIEW 3.3.1 For subdivision development, the Developer shall comply with the procedures and requirements October 2017 Page 3-1

set forth in Article VI, Part 6.02.00 of the County's Land Development Code. This includes the requirement for submittal, review, and approval of a preliminary plat of the proposed project and potable water master plan. The placement of appurtenances in Hillsborough County right-of-way shall be as required in the Utility Accommodation Guide and Rights of Way Use Procedures Manual. 3.3.2 For site development, the Developer shall comply with the procedures and requirements set forth in Article VI, Part 6.03.00 of the County's Land Development Code. The Developer shall submit plans and associated documentation to the Site Engineering Review Section of the Development Services Department for review. This department will either accept or reject the plans with notations for corrections required. All plans shall comply with the requirements of Section 2.0 herein 3.4 PROJECT ACCEPTANCE Following completion of construction and testing, the Developer's Engineer of Record shall submit certified Record drawings and the Asset Data spreadsheet with the as-built information shown on the original design as outlined in Section 1.6 and Section 2.4. Record drawing of a typical wastewater collection system is shown in Figure 3-1. 3.5 SYSTEM DESIGN AND FLOW CRITERIA 3.5.1 The provisions of this Section set forth the general requirements for design of potable water distribution systems and facilities, and provide criteria for determining flow demands. The Engineer shall comply with all the requirements of the Hillsborough County Health Department in addition to the criteria contained herein. 3.5.2 Line Sizing Criteria: The pipe sizing design criteria for water distribution systems shall as a minimum provide for at least 100% of the combined peak hour, maximum day demand rate, plus fire flow. The allowable minimum service pressure under said design condition shall not be less than 20 psi, or 35 psi in a transmission line. Design flows and method of computation shall be submitted to DSD for review by the PUD Utility Planning Team at the time of the preliminary plat or site plan submittal, or at the time of the Master Plan submittal. If the County determines that a line needs to be Oversized, the procedures for sizing and reimbursement, as outlined in Appendix 3, shall be followed. 3.5.3 Minimum Line Size: The minimum pipe size for distribution mains shall be four inches, with the exception that the minimum size for distribution mains serving fire hydrants and fire hydrant branches shall be a minimum of six inches in diameter. 3.5.4 Line Routing The primary feed for the water distribution system for a residential or commercial subdivision shall be routed within County road right-of-way. A secondary feed may be routed within a water, wastewater, or reclaimed water utility easement that is dedicated to the County (design exception), only if there is no road right-of-way available. Multiple points of connection may be required in order to minimize service outage in emergencies, repairs, etc., and to improve fire protection and water quality. The County requires a project s off-site infrastructure to be extended beyond the development point(s) of connection in the right-of-way to the extent of the development's October 2017 Page 3-2

property. As a minimum, at the entrance to the project, the off-site main extension shall be extended within the right-of-way with a valve and one length of pipe with a cap. Refer to the Hillsborough County Public Works Transportation Technical Manual Drawings, latest edition, for the Recommended Utility Locations, TS-1. 3.5.5 Depth of Cover: Cover as measured from finished grade to top of the pipeline shall be a minimum of 36 inches for pipe diameters up to and including 12 inches. Depth of cover for pipes 14 inches or greater in diameter shall be a minimum of 48 inches. When automatic air release valves are required for pipe diameters up to and including 12 inches, the depth of cover of the entire line must be increased to a minimum of 48 inches (to maintain the valve vault flush with the existing or proposed grade). For pipe in FDOT right-of-way, or on County arterial roads, the minimum depth of cover shall be 48 inches. 3.5.6 Flow Criteria Residential Flow Demand: Flow demands for design shall be calculated based on full or projected ultimate development. The average daily flow (ADF) for single family and master-metered residential developments shall be the per unit demand factors contained in the most current Utility Rate Resolution. Peaking factors for design shall be based on total ERCs per Table 3-1. Table 3-1: Water Flow Peaking Factors ERC Population (Thousands) Peak Factor 1 0.0027 4.46 10 0.0270 4.36 100 0.2700 4.10 200 0.5400 3.96 300 0.8100 3.86 500 1.3500 3.71 1000 2.7000 3.48 2000 5.4000 3.21 >5000 13.5000 2.82 Commercial Flow Demand: Flow demands for design shall be calculated based on the appropriate estimating factor found in Table 1 of the most current Utility Rate Resolution. Peaking factors for design shall be based on total ERCs per Table 3-1. Fire Flow: Fire flows shall be calculated in accordance with the fire flow requirements specified by Insurance Services Office (ISO) based on population, density, and hazardous features of the proposed construction. The minimum residual pressure at peak hour, maximum day demand condition, plus fire demand shall not be less than 35 psi for transmission mains and 20 psi for distribution mains. 3.5.7 Connection Feasibility: Contact the PUD Utility Planning Team for determining the feasibility of connecting developments of three ERC s or less. October 2017 Page 3-3

3.5.8 Well Capacity: If County water service is not available, private wells should be designed to provide a capacity of maximum day demand with the additional consideration that combined with storage the entire system must be capable of producing flows of peak hour, maximum day demand, plus fire flow. Where the design of the system for fire flow is not practical, alternative means of providing fire flow such as dry hydrants may be used subject to approval of the DSD Site Engineering Review Section and the County Fire Marshal s Office. 3.5.9 Fire Hydrant Spacing, Location, and Flow Manufacturing and Industrial Areas: Fire hydrants shall be placed every 300 feet along the right-of-way with a maximum of 150 feet to the last lot. The minimum required fire flow shall be 1000 gpm, provided by either: 1) each hydrant individually, or 2) multiple hydrants flowing simultaneously. The required fire flow shall be determined by the County Fire Marshal s Office as part of the preliminary plan review process. Hydraulic capacity of the system may be able to provide fire flow above the 1000 gpm minimum, but any required fire flow not provided by the system must be provided onsite. Commercial and Apartment Areas: Fire hydrants shall be placed every 500 feet along the right-of-way with a maximum of 250 feet to the last lot. The minimum required fire flow shall be 1000 gpm, provided by either: 1) each hydrant individually, or 2) multiple hydrants flowing simultaneously. The required fire flow shall be determined by the County Fire Marshall s Office as part of the preliminary plan review process. Hydraulic capacity of the system may be able to provide fire flow above the 1000 gpm minimum, but any required fire flow not provided by the system must be provided onsite. Residential Areas: Fire hydrants shall be placed a maximum of 500 feet apart along the right-of-way with a maximum of 500 feet to the last lot. The minimum flow from each hydrant shall be 750 gpm. Other Areas: Fire hydrants shall be placed a maximum of 1,000 feet apart, along the right-of-way of rural roads or other areas as approved by the County on a case-by-case basis. 3.5.10 Temporary Water Service for Construction The provisions set forth herein shall be applicable to all construction projects. The developer shall be responsible to submit a temporary water plan (Plan). The Plan shall describe how water will be provided and metered for construction needs and, if applicable, fire demand. It shall include the maximum peak hour flow which will be required prior to acceptance for occupancy. The Plan shall be submitted to the Development Services Department along with the required construction plans. Water service for construction shall be supplied using a temporary construction assembly as described in PUD Technical Specification 331001. Private sources, such as wells, may also be acceptable to the County. October 2017 Page 3-4

3.6 WATER DETAILS Figure 3-1: Water Detail No. TMW-1 October 2017 Page 3-5