Lateral Connections Pioneering Evolving Connecting

Similar documents
THOMAS. Buffalo Saddles. Tap In Products PIPE PRODUCTS. Universal Live Tap In Saddles for All Rigid Pipe Materials.

THOMAS. Buffalo Saddles. Tap In Products PIPE PRODUCTS. Universal Live Tap In Saddles for All Rigid Pipe Materials.

FERNCO PIPE CONNECTORS AND COUPLINGS FERNCO FLEXIBLE COUPLINGS

AVK Couplings and Adaptors

Perfect Manhole System Precast concrete manholes with load bearing elastomeric joints Installation Manual

Georg Fischer Waga N.V. The reliable wide range fitting for large pipe diameters DN450 - DN600 MULTI/JOINT XL


Viking Johnson Couplers and Flange Adaptors

List of products of harmonised standards Code 28: PIPES-TANKS AND ANCILLARIES NOT IN CONTACT WITH WATER INTENDED FOR HUMAN CONSUMPTION

Perfect Manhole Installation Manual May 2012 Rev 8 Perfect Manhole System Precast concrete manholes with load bearing elastomeric joints

VIKING JOHNSON EASIRANGE. Repair and Tapping Solutions

DUCTILE IRON PIPES AND FITTINGS DETAILED PRODUCTS SPECIFICATIONS

TOTAL PIPING SOLUTIONS, INC. Quick Cam. Rapid Seal Repair Clamp. Patent Pending Technical Specifications

San Antonio Water System Standard Specifications for Construction ITEM NO. 848 SANITARY SEWERS

TABLE OF CONTENTS. Chapter 3 - WATER MAIN, VALVES, HYDRANTS AND APPURTENANCES. Chapter 4 - SANITARY SEWER. Chapter 5 - STORM SEWER

(For compliance with the new sewers for adoption regulation or building regulations part H1)

The Viking Johnson range of MaxiFit products - High tolerance pipe couplings - MAXIFIT

EASI-BASE DRAINAGE & WATER MANAGEMENT. v2.1

PVC Fittings & Laterals for Solid-Wall PVC Sewer Pipe

SECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS

EVALUATION SUBJECT: AKDUCT AND AKDUCT PREMIER

The system: it supports 3 load classes (A15, B125, C250) in compliance with Standard EN 1433

A. Gravity-Flow, Nonpressure, Drainage-Piping Pressure Rating: 10-foot head of water (30 kpa).

Copper-Type K soft Drawn 40, 50 HDPE 100 and larger

1.02 RELATED WORK: Refer to the following sections for related work:

CS-13 TRENCHLESS TECHNOLOGY TABLE OF CONTENTS

The Concrete Solution

SUPPLEMENTARY SECTION: STANDARD SPECIFICATIONS PAGE 1 STORMWATER MAINS & CULVERTS MAY 2018

GUIDANCE MEMO NO : GUIDANCE CRITERIA FOR THE SEPARATION OF WATER MAINS AND NON-POTABLE PIPELINES

UltraGrip Optimum Wide Tolerance Repair Solution

FS-DUO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.2 cm)

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SV24. Submittal Special Precautions Specifications Installation. 12½" (31.8 cm) 12½" (31.8 cm) 12" (30.5 cm) 12" (30.5 cm) 12" (30.

Pipeline Accessories. PSI Wall Sleeves. General Information Selection Guide Technical Data Installation Instruction

Adoptable and Non-Adoptable Assemblies.

SECTION STORM SEWER COLLECTION SYSTEM

SECTION SANITARY SEWER SYSTEM

Installation Procedure FP McCann DN1050 Easi-Pit

Georg Fischer Waga N.V. The connection for all pipe diameters Restraint - non restraint DN50 - DN600 MULTI/JOINT 3000 Plus

Contents. dimensions and weights external loads deflection and testing installation...17

TABLE OF CONTENTS

CITY OF BRANSON MUNICIPLE CODE Chapter 18 BUILDINGS AND BUILDING REGULATIONS ARTICLE V. RESIDENTIAL CODE

For Underground Burial or Under Slab Applications. Can Be Fabricated For Both Positive And Negative Pressure

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.

SECTION PRECAST CONCRETE MANHOLES

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Read Only Document Not For Distribution

CPM Concrete Drainage Systems

RAINWATER HARVESTING SYSTEMS

UNIVERSITY OF MISSOURI Hydronic Energy Distribution 2016 Q1

Effective Date: Revision #: 1. Section H: Repair Sleeves, Couplings, Clamps & Non-Pressure Adapters. Pipe Adapters, Non-Pressure

TAPPING SADDLES DN 40 - DN 450

C900/RJ. CertainTeed. PVC Pipe. with CertainTeed s proven Certa-Lok restrained joint system. Directional Drilling

RAINWATER HARVESTING SYSTEMS

Testing. Test drainage products according to the applicable AASHTO or ASTM specification, except as otherwise noted.

SECTION B. Product Data: Provide manufacturer's standard details and installation instructions.

missionrubber.com UNDERGROUND COUPLINGS LATERAL CONNECTIONS HYDROSTATIC TESTING FOR CLAY, PLASTIC & OTHER PIPES / ACCESSORIES

Weholite LIGHTWEIGHT PIPE SYSTEM

CITY OF FARGO SPECIFICATION SANITARY SEWER

WANG TAPPING SADDLES. fast, permanent tapping SOLUTION FOR BOTH rigid and flexible pipe types FEATURES DESCRIPTION APPLICATION TECHNICAL DATA

Sewerage Code WSA Addendum PART 4 - CONSTRUCTION

BUILD A SHOWER CUBICLE

SPECIAL SPECIFICATION 5925 Polyvinyl Cloride (PVC) Sewer Pipe and Fittings

FOX METRO WATER RECLAMATION DISTRICT MANHOLE / SEWER PIPE MATERIALS AND INSTALLATION SPECIFICATIONS MATERIALS 1. PIPE & FITTINGS

SUPPLEMENTAL SPECIFICATIONS TO STANDARD SPECIFICATIONS FOR WATER MAIN AND SERVICE LINE INSTALLATION NO. 2611

GGI-750. Gravity Grease Interceptor Technical Data. Submittal Special Precautions Specifications Installation

FLAT. The system: it supports 3 load classes (A15, B125, C250) in compliance with Standard EN 1433

SECTION FACILITY SANITARY SEWERS

NCCER Progress Blvd, Alachua, Florida Phone: (888)

Certification Scheme

ACO Building Drainage

SECTION STORM DRAINAGE

SECTION SANITARY UTILITY SEWERAGE PIPING

CEMPUR THE PERFECT COMBINATION OF INNOVATIVE COATING EXPERTISE

Index to Technical Specifications

GGI-750. Gravity Grease Interceptor Technical Data. Submittal Special Precautions Specifications Installation

Amendments to the January 2016 Design Criteria Manual & Supplementary Master Municipal Construction Documents

B-500 / B-600 SERIES

30mm Height Linear Drain Shower Trays

DrainFlex Coils Tee Pieces Y-Pieces

STANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING

Complete Sewer Systems

SECTION SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS

BioPrism Solid Surface

TS 803 DUCTS DUCT INSTALLATION, PROTECTION AND MARKING WITHIN A TRENCH OPEN TRENCH DUCT INSTALLATION PROFILE

Couplings The Perfect Through Wall Connection

ITEM NO. 824 SERVICE SUPPLY LINES (WATER)

FS-TRIO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.

Standard Specifications for Road and Bridge Construction. Adopted January 1, 2012

C900/RJ. CertainTeed. PVC Pipe. with CertainTeed s proven Certa-Lok restrained joint system. Directional Drilling

SECTION 401 WATER PIPE AND FITTINGS 2.2 POLYVINYL CHLORIDE (PVC) PIPE AND FITTINGS

SECTION 13. A. Extent of Work: The requirements of this section apply to the piping systems specified elsewhere in these specifications.

HAWLE-range of products

VALLECITOS WATER DISTRICT SECTION POLYVINYL CHLORIDE (PVC) PRESSURE PIPE

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER

POLY-GIB COUPLINGS DN 90 - DN 180

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Pipe to Manhole Connectors, Sealants. Pipe to Manhole Connectors, Sealants

CPM Perfect Manhole. Concrete for Life

Water & Industrial Products Catalog

Transcription:

Lateral Connections Pioneering Evolving Connecting flexseal.co.uk

TM The range in brief... Flexseal is the market leader in the development of lateral connections, used for securely connecting a lateral pipe into a larger diameter main pipe. We can now provide a lateral connection for virtually any application. No adhesives, sealant or concrete are required. Eliminates need to pre-order a factory made junction. Reduces costs, whilst increasing installation options. Minimises time exposed to live sewers. Installation unaffected by weather conditions. Lightweight, easy to handle for quick installation. Robust and should not be damaged under normal site conditions. FA Saddle PA Saddle To connect a 160mm OD PVC lateral pipe into a Twinwall or ribbed main pipe up to DN600. UA Saddle TA Saddle For connection of a DN150 or DN200 lateral pipe into a thick walled sewer pipe. To connect a DN150 lateral pipe into a Twinwall, Weholite or Ridgistorm sewer or storage pipe over DN750. Used to connect a 110mm, 160mm or 200mm diameter lateral pipe into a smooth walled main pipe. FA Saddle A p p r o e d Applies to: FA150B FA200B Used to connect a DN150/DN200 lateral pipe into a thick walled sewer pipe. The range consists of three saddles which are suitable for use with all pipe materials: FA150B, FA200B and the FA150ST. Performance Accepts a deflection on the lateral of 15 degrees. Withstands a vertical load of 2 tonnes No need to excavate around the pipe and disturb the pipe bedding. Withstands 1 bar internal pressure. WRc Approved - PT/243/0405 (FA150B) and PT/244/0405 (FA200B) Scan here for a demo movie Which FA Saddle do I need? FA150B FA200B FA150ST Internal Diameter of Main Pipe 375-1500mm 450-1500mm 250-300mm Wall Thickness of Main Pipe 50-150mm 50-150mm 22-51mm Lateral Pipe Diameter DN150 DN200 DN150

TM TM FA Saddle Range FA150B A p p r o e d To connect a DN150 lateral pipe into a large diameter DN450-1500* thick walled sewer or surface water pipe. Suitable for concrete, vitrified clay, asbestos cement or fibre cement. Cored hole: 172mm *Minimum Wall Thickness of Main Pipe 50mm Lateral Pipe Material Pipe OD Bush Required DN150 Quantum, Cast Iron (SMU, SML, Ensign), 160mm PVC 160-166mm BC12/166 DN150 Ductile Iron, Ultra-Rib. Cast Iron (Drain) 170-177mm BC06/178 DN150 Clay, Supersleve, Twinwall 178-190mm No Bush FA200B A p p r o e d To connect a DN200mm lateral pipe into a large diameter DN450-1500* thick walled sewer or surface water pipe. Suitable for concrete, vitrified clay, asbestos cement or fibre cement. Cored hole: 232mm *Minimum Wall Thickness of Main Pipe 50mm Lateral Pipe Material Pipe OD Bush Required 200mm PVC 200-208mm BC21/205 DN200 Cast Iron (SMU, SML, Ensign) 210-220mm BC08/232 DN200 Vitrified Clay, Ridgidrain, Ductile Iron, DN225 quantum, Ultra-Rib 222-250mm No Bush FA150ST To connect a DN150 lateral pipe into a DN250 or DN300 thick walled solid pipe. Suitable for concrete, vitrified clay, asbestos cement or fibre cement. Cored hole: 172mm Lateral Pipe Material Pipe OD Bush Required DN150 Quantum, Cast Iron (SMU, SML, Ensign), 160mm PVC 160-166mm BC12/190 DN150 Ductile Iron, Ultra-Rib. Cast Iron (Drain) 170-173mm BC08/170 DN150 Clay, Supersleve, Twinwall 178-190mm No Bush For the correct selection to made, please ensure you inform your supplier of the OD and type of lateral pipe being used.

TM PA Saddle A p p r o e d To connect a 160mm OD PVC lateral pipe into a twin wall or ribbed main pipe up to DN600. There are five models available in this range - PA1530, PA1530UR, PA1540, PA1550 and PA1560. Each saddle is suitable for connection into a pipe of a different internal diameter. Performance Will withstand 0.5 bar internal pressure. No need to excavate around the pipe and disturb the pipe bedding. WRc Approved - document PT/290/1009. Materials are unaffected by normal ground conditions. Usage Details PA1530 PA1530UR PA1540 PA1550 PA1560 Internal Diameter of Sewer Pipe 300mm 300mm 400mm 500mm 600mm Wall Thickness of Sewer Pipe Various Various Various Various Various Lateral Pipe Type 160mm PVC 160mm PVC 160mm PVC 160mm PVC 160mm PVC Internal Diameter Of Lateral 150mm 150mm 150mm 150mm 150mm Drilled Hole Size 177mm 177mm 177mm 177mm 177mm Applications This saddle range will cover sewer pipes from DN300 up to and including DN600. The PA1530UR is designed for DN300 Ultra-Rib pipe. The saddles are generally suitable for the standard range of pipe wall thicknesses used by various pipe manufacturers. For these saddles to function correctly the model chosen has to follow the pipe contour as closely as possible. Variations in wall thickness and pipe diameter can affect this. For the correct selection to be made the following information is required about the main pipe: Either the pipe brand / manufacturer and nominal diameter. Or two of the following three dimensions: wall thickness, inside diameter, outside diameter

TM UA Saddle A p p r o e d To connect a DN150 lateral pipe into a Twinwall, Weholite or Ridgistorm sewer or storage pipe over DN750. The UA Saddle can be used with all lateral pipe materials, only in conjunction with a Flexseal coupling. (Please remember to order a suitable coupling to connect the lateral pipe.) Performance No need to excavate around the pipe and disturb the pipe bedding. Will withstand 0.5 bar internal pressure. Withstands a vertical load of 1 tonne. WRc Approved - document PT/266/0707. Materials are unaffected by normal ground conditions. Usage Details Internal Diameter of Main Pipe Wall Thickness of Main Pipe Drilled Hole Size UA Saddle 750-3000mm 40-120mm 177mm Applications This product is suitable for wall thicknesses between 40mm and 120mm. The product is assembled to suit the application. For these saddles to function correctly the model chosen has to follow the pipe contour as closely as possible. Variations in wall thickness and pipe diameter can affect this. For the correct selection to be made the following information is required. Either the pipe brand / manufacturer and nominal diameter. Or two of the following three dimensions: wall thickness, inside diameter, outside diameter Remember to order a suitable coupling to connect the lateral pipe.

TA Saddle Used to connect a lateral pipe into a smooth walled main pipe. Connect a 110mm, 160mm or 200mm OD lateral pipe into a large diameter smooth wall pipe, including concrete, vitrified clay, asbestos cement, fibre cement and PVC. Performance Available for both 45 and 90 lateral connections. Will withstand 0.5 bar internal pressure. Can be applied to pipes of any wall thickness. Seal made on the pipe surface, and secured with straps. which pass around the outside of the main pipe. Usage Details TA11090 TA11045 TA16090 TA16045 TA20045 Internal Diameter of Main Pipe 160-400mm 160-400mm 200-400mm 200-400mm 300-600mm Lateral Pipe 110mm PVC 110mm PVC 160mm PVC 160mm PVC 200mm PVC Hole Size Into Clay / Concrete Pipe 127mm Core Bit See Note 172/178mm Core Bit See Note Hole Size Into PVC Pipe 127mm Hole Saw See Note 177mm Hole Saw See Note Note: If a 45 entry into PVC is required, the rubber gasket can be used as a template and the hole cut with a suitable saw. If a 45 entry into clay or concrete is required, a suitable drilling rig should be used.

Tools A range of Flexseal Lateral Connection installation tools and drilling equipment is available. 8mm Nut Driver Used for installation of the TA Saddle, and supplied when purchasing the product. T-handled Allen key Used for installation of the PA and UA saddles, and supplied when purchasing the product. 8mm Ratchet Spanner An alternative for use installing the TA Saddle. 127mm Hole Saw kit For installation of the TA 11090. Contains a hole saw, drill bit & de burring tool. 177mm Hole Saw kit For installation of the TA16090. Contains a hole saw, drill bit & de burring tool. 232mm Diamond Tipped Core Bit. Available to buy or hire, for the installation of the FA200B. 172mm Diamond Tipped Core Bit. Available to buy or hire, for the installation of the FA150B, the FA150ST and the TA16090 into a clay/concrete pipe. For more information on tool requirements please contact our office on 01226 340 888 or email sales@flexseal.co.uk.

Flexseal Ranges... Flexible Couplings Channel Drainage Lateral Connections Flexseal manufacture the largest range of flexible drainage couplings in the marketplace, supplying UK and International markets. Standard, Extra Wide, Adaptor, Drain plus other drainage coupling ranges are available up to 3m in diameter. Flexseal supply a comprehensive range of domestic and commercial channel drainage systems and accessories. A drainage channel system for any application. Flexseal s range of saddle connections and ancillaries guarantee a secure connection between a lateral pipe and a larger diameter main pipe. Plumbing Range Pipe Seals Pipe Doctor Flexseal manufacture a range of pipe / plumbing couplings in PVC and high performance EPDM plus accessories for replacing and repairing plumbing systems with ease and efficiency. The Flexseal Pipe Seal range of products ensures a waterproof seal when a pipe passes through the wall of a tank, pipe or other underground structure. All products will guarantee a secure connection, every time. The WRC Approved no-dig patch repair kit from Source One Environmental provides a quick and easy solution to repairing damaged drain and sewer systems, without the need for excavation. Proud to be a Drainage Couplings Plumbing Couplings Lateral Connections Pipe Seals Channel Drainage Please contact us if you d like more information: Endeavour Works, Newlands Way, Valley Park, Wombwell, Barnsley, S73 0UW England T: +44 (0)1226 340 888 F: +44 (0)1226 340 999 E: W: Issue #1 2013