Sby SR Instruments, Inc.

Similar documents
DS-520 Digital Indicator Operation Manual 73366

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

LOW PROFILE FLOOR SCALE

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

PORTABLE CHAIR SCALES BEAM and DIGITAL TYPES MODELS 475, 4751, 6475, 6475k and 6475KGEU

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

Owner s Manual & Safety Instructions

Model Defibrillator Platform OPERATIONS/MAINTENANCE MANUAL. IMPORTANT Keep manual on file at all times.

Model Defibrillator Platform OPERATIONS/MAINTENANCE MANUAL. IMPORTANT Keep manual on file at all times.

PD662 LOOP-POWERED METER

Safety Precautions. 3. Cabinet Assembly 4. Operating buttons / functions.5-6. Machine Operation

User Guide M Rev A 09/15

Precision Automatic Vacuum Control (PAVC+)

HDI 2200 Choke Position Indicator

Model K11. 10ppm Accuracy DC Voltage Standard. Operating Manual

BESTMOVE STANDING TRANSFER AID

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

DRS220. DRS220 Digital Refrigerant Scale Limited Warranty. Digital Refrigerant Scale

DC-688. When Accuracy Counts

WARNING. Introduction ! ATTENTION

Model 5200 Cargo Lift Installation and Operation Manual

ENMET Corporation PO Box 979 Ann Arbor, MI GS-24-DF. Manual October 2003 MCN-314, 12/05/03

BESTMOVE STANDING TRANSFER AID

DMC When Accuracy Counts

TL-600 MOBILE PHASE HEATER

PINLESS LCD MOISTURE METER WITH TRICOLOR BAR GRAPH USER S MANUAL

DICKSON TH8 DICKSON. Temperature & Humidity Chart Recorder Operation. Useful Features. Applications & Product. Specifications. Product.

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

OPERATOR S MANUAL Model 56A Prefeed / Dereeler

BC Series Compact Counting Scale INSTRUCTION MANUAL

POWER PINNER BENCH HAND WELDER 7250 OPERATOR S MANUAL

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.

MODEL 2500KL / MODEL 2600KL DIGITAL WHEELCHAIR PATIENT SCALES

Calibrate Accessory Actuators Instructions

MTTC User Manual. Innovative Technology for a Connected World. General Description. Specifications and features

Model 5200 Cargo Lift Installation and Operation Manual

and Shield with Vertical Needle Holder REF 90072

Xxxxx Xxxxxx OM-CP-TEMP101A. Temperature Data Logger with 10 year battery life INSTRUCTION SHEET MQS5026/0117

Model E100 Gauss Meter

Infant Warmer Care Station Cabinet Light

TEACO TRUCK DOCK PARK ASSISTANT. MODEL DockView -16 FORWARD/REVERSE READING DISTANCE INDICATOR

Global Water globalw.com. Global Water. Instrumentation, Inc.

Dynatronics Parallel Bars

DRYWALL DOLLY 900 LB. CAPACITY

PINLESS LCD MOISTURE METER WITH TRICOLOR BAR GRAPH USER S MANUAL

1075 Fluoroscopy Stretcher

RL4050LS. Electronic Load Shackle. Installation Guide

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

Global Water Instrumentation, Inc.

WeighSouth. WBT Toploader Balance

L505 VISUAL LEVEL INDICATOR. Dip-Tape Visual Level Indicator INSTALLATION AND OPERATIONS MANUAL

OPTO BRANCH 6 RJ45. user manual. ELATION OPTO BRANCH 6 RJ45 user manual

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features

General-Purpose Scale Bases

Model T2642E Wall Mount. Television Wall Mount with Tilt Option

OM-CP-QUADPROCESS 4-Channel Low Level DC Current Data Logger. OM-CP-OCTPROCESS 8-Channel Low Level DC Current Data Logger INSTRUCTION SHEET

Thermoelectric Cooler

PC-1 Programmable Controller

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Effective This guide supersedes all previous versions

Introduction Specifications Control Panel / Remote Unit Diagrams Setting Up the Unit Maintaining the Unit Safety info / Warnings Warranty Information

RJE INTERNATIONAL, INC. STI- 350 R EV 2.2

VN Series Floor Scale Instruction Manual

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

APC Step-Down Transformer. Models: AP9626, AP9627, and AP9628

Troubleshooting Guide 9702 Series

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

DIGITAL PORTION SCALE PS-5 OWNER S Manual

BESTMOVE STANDING TRANSFER AID

Dandy Leveler UDLV-150 & UDLV-500 (New Style)

REF DOC # STANDARD IMAGING, INC Murphy Drive Middleton, WI TEL TEL FAX

UNI BAR. user manual. ELATION UNI BAR user manual

LF1600 Stand Assist Assembly and Operation Manual

Mechanical Post Lift. Owner s Manual

VI PARTS LIST. , ELECTRIC FRYER PARTS LIST ITEM DESCRIPTION MODELS PART # 10x x24

Model M120 Mini Temperature/Humidity Meter

INSTALLATION AND OPERATION MANUAL

Xxxxx Xxxxxx Autoclave Validation Data Logging System

Address: City: State: Zip: Day Phone: Fax: 5. Where Were Your Products Purchased and/or Installed: Installer s Name/Company:

MODEL NUMBER: 1419 SERIES

Model # 922-S4. 12/18/2013 Page 1 of 8

WALL SHELVES. Cleaning and Maintenance INSTRUCTION MANUAL

FO-6000 Inline FO Filter Holder FO-6000FILT INSTRUCTION MANUAL. Serial No. World Precision Instruments

INSTALLATION AND OPERATION MANUAL

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., UNIT B-1, TEMECULA, CA PHONE (951) FAX (951)

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

INSTALLATION MANUAL RECTANGULAR COLUMN

INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL

Model 10A. Model 20A. Operating Manual. ECG Simulator. ECG / Arrythmia Simulator

Bravo Platform Unpacking Guide

1-300 SERIES Endover Rotator Operator s Manual for Morse End-Over-End Drum Rotators Series

Model # 358PS-OP. 12/13/2013 Page 1 of 12

Single Mount Installation Instructions

AM1643 Full Immersion Platinum Resistance Thermometer User s Guide

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

J60 Lithium Ion UPS 350VA Model User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Model # 358PS-RDP. 12/13/2013 Page 1 of 12

Wash Down Duty Non-Contact Sensor

92831 TEL: (714) FAX:

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

Transcription:

Part No.: MAN947IFS_170629 Page 1 of 12 Sby SR Instruments, Inc. SRV947IFS REMOTE DISPLAY PLATFORM SCALE Operating and Service Manual

Part No.: MAN947IFS_170629 Page 2 of 12 TABLE OF CONTENTS TABLE OF FIGURES...2 PACKING CHECKLIST MODEL SRV947IFS...3 ASSEMBLY...4 REPLACEMENT PARTS AND ACCESSORIES...5 SYSTEM DESCRIPTION AND INTENDED USE...5 MAINTENANCE AND CLEANING...6 STORAGE AND TRANSPORTATION...6 SPECIFICATIONS...7 BUTTON FUNCTIONS...8 BASIC SYSTEM OPERATION...9 CALIBRATION...10 TROUBLESHOOTING...10 WARRANTY...11 TABLE OF FIGURES Figure 1: Wall Box Assembly/Conduit Placement... 4 Figure 2: Concrete Fill... 4 Figure 3: Button Display... 8 Figure 4: Calibration Table... 10

Part No.: MAN947IFS_170629 Page 3 of 12 PACKING CHECKLIST Model SRV947IFS Portable Platform Scale DESCRIPTION QUANTITY PLATFORM PIT FRAME ASSEMBLY FRONT PANEL/WALL BOX ASSEMBLY SIGNAL CABLE ASSEMBLY CONDUIT CALIBRATION CERTIFICATE WARRANTY CARD MANUAL

Part No.: MAN947IFS_170629 Page 4 of 12 ASSEMBLY STEP 1: Unpack the scale system and check parts against the PACKING CHECKLIST. If there are any missing or damaged parts, please call the Service Hotline at: 1-800-654-6360. STEP 2: Verify that the serial number on the label of Wall Box Display matches that on Platform Base. STEP 3: (Figure 1) Mount Wall Box Display into wall and run the conduit, with connector cable inside, down through wall and into pit as shown. STEP 4: Prepare pit area to accept the Scale Frame. It is recommended that a properly plumbed drain be installed in the center of pit to avoid any water buildup that might damage scale. STEP 5: Center the Scale Frame in the pit. Figure 1: Wall Box Assembly/Conduit Placement STEP 6: (Figure 2) Back fill around the perimeter of the Pit Frame Assembly with 3000PSI concrete. Trowel the concrete level with the scale frame and existing floor. Trowel the base of the pit level with the base of the frame with a gradient toward the centered drain, if used. Conduit and cable should be left free so cable can be easily connected to the Platform Assembly. STEP 7: When the concrete has set, connect the Cable Assembly to the mating connector on the Platform Assembly. STEP 8: Carefully lower the Platform Assembly into the Pit Frame Assembly. Ensure that Platform feet set into locators on Pit Frame and that extra cable does not interfere with platform. Figure 2: Concrete Fill STEP 9: Install building ground wire and green ground wire from Display Front Plate into the terminal lug in the wall box STEP 10: Connect signal cable to the mating connector on the Display Front Panel STEP 11: Connect A/C power wires to the power supply wire leads STEP 12: Install Front Panel Assembly to the previously mounted Wall Box. Use supplied star washers and screws. Ensure screws are securely tightened. STEP 13: Restore power to the display

Part No.: MAN947IFS_170629 Page 5 of 12 REPLACEMENT PARTS AND ACCESSORIES Part # CA8974 SE6000-6 MF2284 Description Display Label Signal Cable Replacement Foot SYSTEM DESCRIPTION AND INTENDED USE SYSTEM DESCRIPTION The SRV947IFS Portable Platform Scale is a low profile design which allows the animal easy access. The SRV947IFS Scale employs the latest in microprocessor and load cell technology to provide accurate and repeatable weight data. Six (6) identically matched transducers are strategically placed to ensure an accurate representation of the patient s weight. The patient s weight is displayed on an LCD screen. With a push of a button, weight data may be viewed in either pounds or kilograms. INTENDED USE The SRV947IFS Portable Platform Scale is a lightweight portable scale designed for use as a weighing system for animals not exceeding 400 pounds or 182 kilograms, gross weight. Please read the following warnings to avoid injury to the animal or attendant. WARNING DO NOT USE FOR ANIMAL TRANSPORT DO NOT EXCEED MAXIMUM LIMIT OF 400 LB / 182 KG

Part No.: MAN947IFS_170629 Page 6 of 12 MAINTENANCE and CLEANING The SRV947IFS Portable Platform Scale is made with a polyurea-coated aluminum platform. Exercise caution when cleaning the display window as it is made of a clear plastic and can be scratched by abrasive cleaners. Mild soap and water is recommended for general cleaning and disinfecting. WARNING DO NOT use pressurized water or steam. The scale system contains microprocessor circuitry and strain gauge sensors that may be adversely affected by exposure to such an environment. STORAGE and TRANSPORTATION STORAGE To maintain proper operation of this instrument, storage and transport conditions should not vary outside the following conditions: Relative Humidity 0% to 85%, Ambient Temperature 14 F to 122 F (-10 C to +50 C). TRANSPORTATION The SRV947IFS Portable Platform Scale has four (4) recessed handles on the underside of the scale for easy portability and a pull tab on the platform surface for ease of removal from the pit frame.

Part No.: MAN947IFS_170629 Page 7 of 12 SPECIFICATIONS MAXIMUM WEIGHT CAPACITY PLATFORM SIZE DISPLAY TYPE DISPLAY RESOLUTION ACCURACY AUTO ZERO AVERAGING POWER SUPPLY CALIBRATION OPERATING CONDITIONS TRANSPORT and STORAGE 400 lb / 182 kg 24 in x 48 in x 2 in (61 cm x 122 cm x 5 cm) 1 digit LCD 0.2 lb / 0.1 kg 0.2% +/- 1 digits of displayed resolution for calibrated range One button operation / Hold for Zero Automatic digital filter 110v AC, 50-60Hz Calibration is traceable to NIST standards Normal operating conditions for this product: Ambient Temperature Range: 68 F to 85 F (20 C to 30 C), Relative Humidity Range: 0%-85%. Avoid exposure to high-pressure water or steam. Storage and transport conditions should not vary outside the following conditions: Relative Humidity 0% to 85%, Ambient Temperature 14 F to122 F (-10 C to +50 C).

Part No.: MAN947IFS_170629 Page 8 of 12 BUTTON FUNCTIONS Figure 3: Button Display ZERO MODE HOLD/ RECAL L The ZERO/WEIGH button is used to clear the Recall memory and start a new weighing cycle. Press and hold for 3 seconds to zero the display. The MODE button is used to select pounds or kilograms. The HOLD/RECALL button is used to lock in the weight currently displayed, or to recall the last saved weight, if nothing is on the scale platform.

Part No.: MAN947IFS_170629 Page 9 of 12 BASIC SYSTEM OPERATION TURNING SYSTEM ON Make sure the scale is free and clear of any obstructions and all six feet are touching a level surface. Press the ZERO button and hold for 3 seconds. The display will read ZERO then display 0.0 when system is ready for weighing. UNIT Press the MODE button to toggle between pounds or kilograms. The system will remain in the same mode as last used unless manually changed. WEIGH The WEIGH button is used to clear the Recall memory and start a new weighing cycle. HOLD/RECALL The HOLD/RECALL button is used to lock in and store the weight currently displayed in system memory. With no weight on the platform pressing the button again will recall the last stored weight and display it for 15 seconds. AUTOHOLD With autohold enabled, when the system detects a stable weight, that value will be stored in system memory. This value can later be recalled by pressing the HOLD/RECALL button with no weight on the platform.

Part No.: MAN947IFS_170629 Page 10 of 12 CALIBRATION NOTE: Ensure that nothing is in contact with the scale system during this procedure. Remove hands from the system when noting the displayed calibration results. CHECKING CALIBRATION STEP 1: Select known calibrated weights, traceable to NIST. NOTE: DO NOT USE barbells or un-calibrated weights. STEP 2: Zero the scale by pressing and holding the ZERO/WEIGH button. STEP 3: Place the calibrated weight on the scale. Wait for scale to stabilize; note scale reading. STEP 4: Scale readings should be within Calibration Tolerance Table (Figure 4). IMPORTANT CALIBRATION TOLERANCE TABLE LOW LIMIT APPLIED LOAD HIGH LIMIT 99.8 100.0 100.2 199.6 200.0 200.4 299.4 300.0 300.6 399.2 400.0 400.8 Figure 4: Calibration Table CALIBRATION CHECK Qualified service personnel only should perform this procedure. Load cells have no user serviceable components and should not be tampered with for any reason. Re-calibration is generally not required, but should be verified periodically to ensure accuracy. The recommendation for calibration check is at least once every 12 months, or as individual maintenance policy requires. CAUTION The integrated circuits and semiconductors on the printed circuit boards may be damaged by electrostatic discharge (ESD). Be sure to use proper handling precautions at all times. TROUBLESHOOTING SYMPTOM REASON/CORRECTIVE ACTION Display reads LOW Ensure scale is on a level surface. Check to make sure all six feet are touching ground and ensure that nothing is touching bottom or sides of platform. For additional information or assistance, phone our Service Hotline: 1-800-654-6360 or e-mail: sri@srinstruments.com

Part No.: MAN947IFS_170629 Page 11 of 12 WARRANTY TWO (2) YEAR LIMITED WARRANTY Each S system is manufactured with high quality components. SR Instruments, Inc. warrants that all new equipment will be free from defects in material or workmanship, under normal use and service, for a period of two (2) years from the date of purchase by the original purchaser. Normal wear and tear, injury by natural forces, user neglect, and purposeful destruction are not covered by this warranty. Warranty service must be performed by the factory or an authorized repair station. Service provided on equipment returned to the factory or authorized repair station includes labor to replace defective parts. Goods returned must be shipped with transportation and/or broker charges prepaid. SR Instruments, Inc. s obligation is limited to replacement of parts that have been so returned and are disclosed to SR Instruments, Inc. s satisfaction to be defective. The provisions of this warranty clause are in lieu of all other warranties, expressed or implied, and of all other obligations or liabilities on SR Instruments, Inc. s part, and it neither assumes nor authorizes any other person to assume for SR Instruments, Inc. any other liabilities in connection with the sale of said articles. In no event shall SR Instruments, Inc. be liable for any subsequent or special damages. Any misuse, improper installation, or tampering, shall void this warranty. DAMAGED SHIPMENTS Title passes to purchaser upon delivery to Transportation Company. Any claims for shortage or damage should be filed with the delivery carrier by purchaser. RETURN POLICY All products being returned to SR Instruments, Inc. require a Return Goods Authorization number (RGA). To receive an RGA, call our Technical Service Team at 716-693-5977 or toll-free in the USA and Canada at 800-654-6360. When inquiry is made, please supply model and serial numbers, purchase order, if the scale was bought on contract, and reason for return. Generally, deleted, damaged, and outdated merchandise will not be accepted for credit. minimum restocking charge of 15% will be assessed on return of current merchandise. All returns are to be shipped FREIGHT PREPAID to: SR Instruments, Inc., 600 Young Street, Tonawanda, NY 14150. RESTOCKING FEE 15% fee for any scale that has been opened and used 10% fee for any scale returned that has been ordered incorrectly or refused delivery with no model change 5% fee if an error in ordering has been made and a different model exchanged No fees will be charged if the scale is returned because of an error on the part of SR Instruments, Inc. No returns accepted after 60 days. A

Part No.: MAN947IFS_170629 Page 12 of 12 S By SInstruments, Inc. Precision & Technology in Perfect Balance