RJE INTERNATIONAL, INC.

Similar documents
RJE INTERNATIONAL, INC. U LB-364EL R EV 3.2

RJE INTERNATIONAL, INC. STI- 350 R EV 2.2

Global Water Instrumentation, Inc.

Global Water globalw.com. Global Water. Instrumentation, Inc.

Global Water Instrumentation, Inc.

REF DOC # STANDARD IMAGING, INC Murphy Drive Middleton, WI TEL TEL FAX

Owner s Manual Calcite Cartridge System

Limited Product Warranty

Model Defibrillator Platform OPERATIONS/MAINTENANCE MANUAL. IMPORTANT Keep manual on file at all times.

Model Defibrillator Platform OPERATIONS/MAINTENANCE MANUAL. IMPORTANT Keep manual on file at all times.

Global Water Instrumentation, Inc.

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

Thermoelectric Cooler

Owner s Manual & Safety Instructions

Global Water Instrumentation, Inc.

Model 292A. Surface Resistance Test Kit. Instruction Manual

User Guide M Rev A 09/15

WARNING. Introduction ! ATTENTION

Model 10A. Model 20A. Operating Manual. ECG Simulator. ECG / Arrythmia Simulator

and Shield with Vertical Needle Holder REF 90072

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

P R I C E L I S T 1

TL-600 MOBILE PHASE HEATER

Ecologix Environmental Systems, LLC

PORTABLE CHAIR SCALES BEAM and DIGITAL TYPES MODELS 475, 4751, 6475, 6475k and 6475KGEU

UNI BAR. user manual. ELATION UNI BAR user manual

TR1 TR2. Transformer / Relay Adapter. Installation Manual. Rev 1.1 Feb. 22, Deklin Technologies Inc 413 Childe Harolds Lane Brentwood, TN 37027

Manual No Revision MODEL GLI HAND-HELD/PORTABLE TOTAL/FREE CHLORINE METER

Wash Down Duty Non-Contact Sensor

WATER LEVEL METERS DIPMETER DIPMETER (WITH TEMPERATURE OPTION) ANTI-FOAM DIPMETER

REED SWITCH PROBE (RSP) FOR USE WITH GEOSENSE GEO-XM MAGNETIC EXTENSOMETER SYSTEMS

ENMET Corporation PO Box 979 Ann Arbor, MI GS-24-DF. Manual October 2003 MCN-314, 12/05/03

HDI 2200 Choke Position Indicator

Rocker Tool Post ASSEMBLY AND OPERATING INSTRUCTIONS

Global Water Instrumentation, Inc.

INSTALLATION, OPERATION, AND MAINTENANCE

LOAD RAMP 1000 LB. CAPACITY

78-RK VARIABLE SPEED HEAVY DUTY VIBRATOR OPERATING MANUAL

OPTO BRANCH 6 RJ45. user manual. ELATION OPTO BRANCH 6 RJ45 user manual

welded steel PIPE Nipple price sheet

Instruction Manual HK285. Note: The Owner/Operator must read carefully and understand all the information presented here before operation.

Quick-Start Operating Guide Document No Exhaust Fume Hood Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010

Model TS-100 Tubing Spider Installation, Operation, Service and Parts Book Manual

DAKE SINGLE LEVERAGE ARBOR PRESS. Model 1 INSTRUCTIONAL MANUAL

SBF-P 2000 & SBF-P 2254 FLAT TOP CHAIN CONVEYORS

DS-520 Digital Indicator Operation Manual 73366

Owner s Manual & Safety Instructions

Signal Follower Card. Instruction Manual Model C

ACCESS DOOR TRADE PRICE GUIDE

Price Book Calypso. collection

TEST & MEASUREMENT TOOL LIMITED WARRANTY Every Test & Measurement Tool is warranted for five (5) years from the date of purchase *.

WARNING ELECTRIC PALLET TRUCK EPT Revised A company dedicated to solving ergonomic and material handling problems since 1955.

Lighting Services Inc. QuickShipExpress 5-10 Day Service

INSTALLATION, OPERATION, AND MAINTENANCE

Miniglaze/2. Owner & Operator's Manual PORCELAIN STAINING AND GLAZING FURNACE. Model No: Voltage: V 50/60Hz V 50/60Hz

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

Drag Chain Conveyor Installation and Operation Manual

Brede EXPOSITION SERVICES ALLIED Convention Services Division 2502 Lake Orange Drive, Orlando, FL * 407/ * FAX 407/

J1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL

1075 Fluoroscopy Stretcher

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

92831 TEL: (714) FAX:

NOTICE: To the prices and terms quoted, there will be added any manufacturers or sales tax payable on the transaction under any effective statute.

NOTICE: To the prices and terms quoted, there will be added any manufacturers or sales tax payable on the transaction under any effective statute.

CUSTOMER S OWN MATERIALS (COM)

STEEL PIPE NIPPLES SEAMLESS Price Sheet PNS-9.16C Effective: September 5, 2016 Cancels Price Sheet PNS-10.15C of October 5, 2015

Address: City: State: Zip: Day Phone: Fax: 5. Where Were Your Products Purchased and/or Installed: Installer s Name/Company:

User s Manual. June 23, 2017 P/N Revision D. TURNER DESIGNS 1995 N. 1 st Street San Jose, CA Phone: (408) FAX: (408)

Effective This guide supersedes all previous versions

Hayward Flow Control

TrueClean ToteTilter TM

L505 VISUAL LEVEL INDICATOR. Dip-Tape Visual Level Indicator INSTALLATION AND OPERATIONS MANUAL

TERMS AND CONDITIONS: (Stated in U.S. Dollars):

MD Power Supply -48Vdc +Bias Tee

4-Wire Buffer Amplifier. User Manual

DMX-BRANCH/4. user manual. ELATION DMX-BRANCH/4 user manual

END TRUCKS WHEEL SIZES: 9", 12", 15" & 18"

ER6-SERIES1:6 SERVICE MANUAL

STEEL PIPE COUPLINGS

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

4 rotary milling table

Domtar Standard Terms of Sale March 2017

BRG Tiger Digital Clock/Timer/Counter

Terms & Conditions of Sale May Applications of Standard Terms. Prices and Payment. Taxes

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

PTC1. Paint Test Cell Kit

FPF-P 2045 FLAT TOP CHAIN CONVEYOR

ECH 2 O EA-10. Soil Moisture Sensor. Integrator s Guide

Q45WQ. Water Quality Monitoring System. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

MANUAL. ENGLISH Antenna Booster Ordercode: D1425. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

ER6-SERIES1:6 SERVICE MANUAL

DGF-P 2001 CONVEYORS

Global Water Instrumentation, Inc.

Fire Protection Valves price sheet

INSTALLATION PROCEDURE

SQ-1 ROOF TRUSS WEG-IT TABLE

OPERATOR S MANUAL Model 27G Rotary Collet Magnet Wire Stripper

Sby SR Instruments, Inc.

ODYSSEY FLOOR MODEL. Owner s Manual. O-6400-F shown rev 118

Transcription:

RJE INTERNATIONAL, INC. U LB-364 U N D ERWATER LOCATOR B EACON U SER S MANUAL R EV 3.1 1 0 / 2 3 / 2 0 1 7

PROPRIETARY MATERIAL The descriptions, procedural information, photos, figures, drawings, and illustrations in this manual are the property of Materials may not be reproduced or disseminated without the prior written consent of RJE International. RJE International reserves the right to make changes in design or specifications at any time without incurring any obligation to modify previously installed units. This manual is provided for information and reference purposes only and is subject to change without notice. LIMITED WARRANTY (RJE) guarantees its products to be free from defects in materials and workmanship for a period of one year from the date of shipment. In the event a product malfunctions during this period, RJE s obligation is limited to the repair or replacement, at RJE s option, of any product returned to the RJE factory. Products found defective should be returned to the factory freight prepaid and carefully packed, as the customer will be responsible for any damage during shipment. Repairs or replacements, parts, labor, and return shipments under this warranty will be at no cost to the customer. This warranty is void if, in RJE s opinion, the product has been damaged by accident or mishandling, altered, or repaired by the customer, where such treatment has affected its performance or reliability. In the event of such mishandling, all costs for repair and return freight will be charged to the customer. All products supplied by RJE that are designed for use under hydrostatic loading have been certified by actual pressure testing prior to shipment. Any damage that occurs as a direct result of flooding is NOT covered by this warranty. If a product is returned for warranty repair and no defect is found, the customer will be charged a diagnostic fee plus all shipping costs. Incidental or consequential damages or costs incurred as a result of a product s malfunction are not the responsibility of RJE. All returned products must be accompanied by a Case Number issued by RJE. Shipments without a Case Number will not be accepted. LIABILITY RJE shall not be liable for incidental or consequential damages, injuries, or losses as a result of the installation, testing, operation, or servicing of RJE products. ii Tel: (949 ) 727-9399 Fax: (949) 727-0070 sales@rjeint.com www.rjeint.com

RETURN PROCEDURE Before returning any equipment to RJE, you must contact RJE and obtain a Case Number. The Case Number assists RJE in identifying the origin and tracking the location of returned items. When returning items to RJE from outside the United States, follow the checklist presented below to prevent any delays or additional costs. Include with all shipments two copies of your commercial invoice showing the value of the items and the reason you are returning them. Whenever possible, send copies of the original export shipping documents with the consignment. Route via courier (FedEx or UPS). If there is more than one item per consignment, include a packing list with the shipment. It is acceptable to combine the commercial invoice and packing list with the contents of each carton clearly numbered and identified on the commercial invoice. If it is necessary to ship via air freight, contact RJE for specific freight forwarding instructions. You will be charged for customs clearance and inbound freight. Insure the items for their full value. Refer to the RJE issued Case Number on all documents and correspondence. Prepay the freight. TITLE Title shall pass to buyer on delivery to carrier in Irvine, CA. Risk of damage or loss following such delivery shall be to the buyer and RJE International shall in no way be responsible for safe arrival of the shipment. Title shall so pass to buyer regardless of any provision for payment of freight or insurance by RJE International or of the form of shipping documents. If shipment is consigned to RJE International, it shall be for the purpose of securing buyer s obligations under the contract. iii Tel: (949 ) 727-9399 Fax: (949) 727-0070 sales@rjeint.com www.rjeint.com

TABLE OF CONTENTS FORWARD WARRANTY 1 - Introduction to the ULB-364 1.1 Overall Description of the ULB-364 series... 1 1.1.1 The ULB-364... 1 2 - ULB-364 Specifications 2.1 ULB-364 Specifications... 2 3 - Operation & Installation Notes 3.1 Introduction... 3 3.2 Unpacking... 3 3.3 Setting the ULB-364 Transmit Frequency and Repetition Rate... 3 3.4 Activating the ULB-364... 4 4 - ULB-364 Maintenance 4.1 Maintenance... 5 4.2 Battery Test... 5 4.3 Replacing the ULB-364 Batteries... 6 ILLUSTRATIONS FIGURE 1-1 ULB-364 Beacon... 1 FIGURE 3-1 ULB-364 Disassembly... 3 FIGURE 3-2 Frequency Select Switch... 4 FIGURE 4-1 ULB-364 Disassembled... 6 FIGURE 4-2 ULB-364 Battery Connections... 6 FIGURE 4-3 ULB-364 Battery Installation... 7 TABLES TABLE 2-1 ULB-364 Specifications... 2 TABLE 3-1 Frequency/Rep Rate Select Switch Settings... 4 TABLE 4-1 Voltage Reading vs. Battery Status... 5 iv Tel: (949 ) 727-9399 Fax: (949) 727-0070 sales@rjeint.com www.rjeint.com

Section 1 INTRODUCTION TO THE ULB-364 1.1 Overall Description The ULB-364 series beacons are underwater acoustic signaling devices used in subsea marking and relocation of equipment and other assets. The ULB-364 is a free-running pinger that allows the user to adjust the frequency and repetition rate of the pulse. The beacon comes in two versions: the ULB-364 and ULB-364 Extended Life (EL). Housing Transducer Figure 1-1 ULB-364 Beacon 1.1.1 The ULB-364 The ULB-364 is a battery-operated beacon that can relocate underwater targets as far down as 1,000 meters. With lightweight, aluminum housing and user-adjustable settings, the ULB-364 can be deployed for up to 180 days, depending on the settings and batteries used. The extended life version, the ULB-364 EL, can be deployed for up to 540 days. 1

Section 2 ULB-364 SPECIFCATIONS 2.1 ULB-364 Specifications Table 2-1 ULB-364 Specifications Transmit Frequency 27, 29, 32, 34, 37, 39, 42, 45 khz (user adjustable) Acoustic Source Level Transmit Repetition Rate Transmit Pulse Length Activation 165 db re 1 Pa @ 1 meter 1 pulse per second/1 pulse every two seconds (user adjustable) 5 ms Battery activation Battery 9 Volt (PP3) Alkaline or Lithium Battery, qty.: two (2) Operating Life Alkaline: 1 Pulse per second: 30 days 1 Pulse every 2 seconds: 40 days Lithium: 1 Pulse per second: 90 days Operating Temperature Range -40C to +125C Storage Temperature Range -65C to +150C Operational Depth Housing Material Dimensions Weight Specifications are subject to change. 1 Pulse every 2 seconds: 180 days 1,000 m (3,080 ft) Aluminum; O-ring sealed 20.32 cm (L) x 5.71 cm (D) 8.00 in (L) x 2.25 in (D) In Air: 806g (1.8lbs) 2

Section 3 3.1 Introduction OPERATION & INSTALLATION NOTES The ULB-364 is activated by shorting the water switch. It can operate in both fresh and salt water. The ULB-364 allows the user to select an operating frequency by rotating a switch on the printed circuit board (PCB), choosing between 27, 29, 32, 34, 37, 39, 42, and 45 khz. This switch also allows the operator to change the repetition rate from once per second to once every 2 seconds, extending the battery life of their device. With the right settings and using non-rechargeable 9-volt lithium batteries, the ULB-364 can emit a signal for a maximum of up to 180 days. 3.2 Unpacking When opening the shipping carton, carefully inspect each pinger as it is unpacked, and report any damage to the freight carrier and to RJE International. As with any sophisticated electronic equipment, RJE International products should be handled with a reasonable amount of care during unpacking, transporting and storing. Pay specific attention to the housing and transducer to make sure that there is no damage. 3.3 Setting the ULB-364 Transmit Frequency and Repetition Rate Loosen and remove the knurled locking collar from the housing and gently remove the end cap. Figure 3-1 ULB-364 Disassembly Orient the ULB-364EL assembly so the rotary switch is located as shown below. 3

Figure 3-2 Frequency Select Switch Set the switch position of SW1 to the position for the desired channel and/or frequency, using the table below for reference (Table 3-1): Table 3-1 Frequency/Rep Rate Select Switch Settings Mode SW Selection 27kHz @ 1 pulse per second 0 29kHz @ 1 pulse per second 1 32kHz @ 1 pulse per second 2 34kHz @ 1 pulse per second 3 37kHz @ 1 pulse per second 4 39kHz @ 1 pulse per second 5 42kHz @ 1 pulse per second 6 45kHz @ 1 pulse per second 7 27kHz @ 1 pulse per 2 seconds 8 29kHz @ 1 pulse per 2 seconds 9 32kHz @ 1 pulse per 2 seconds A 34kHz @ 1 pulse per 2 seconds B 37kHz @ 1 pulse per 2 seconds C 39kHz @ 1 pulse per 2 seconds D 42kHz @ 1 pulse per 2 seconds E 45kHz @ 1 pulse per 2 seconds F 3.4 Activating the ULB-364 The ULB-364 is activated by shorting the water switch. See section 4.3 for instructions on how to install batteries. 4

Section 4 ULB-364 MAINTENANCE 4.1 Maintenance After each deployment, take the following steps to assure continued reliable performance from the ULB-364: Wash the exterior of the equipment with fresh water and mild detergent. Pay attention to cleaning film build-up on the transducer end. Make sure the equipment has been thoroughly dried and the batteries have been removed before storage. Inspect O-rings for damage and wear. Order needed replacements if required. 4.2 Battery Test This test allows you to roughly determine the state of the 9-volt battery without removing the battery from the unit. All batteries are different and we recommend that you replace the battery after every deployment to ensure full operational life. Using a Volt/Ohm Meter (VOM) set to measure DC voltage, place the meter s probes across the water switch contacts located on top of the transducer. Measure the voltage and use the chart below. Note: Polarity is not important in this measurement. Voltage Reading Battery Status >/= 3 vdc New >/= 2.8 vdc Good >/= 2.75 vdc Marginal < 2.75 vdc Replace Table 4-1 Voltage Reading vs. Battery Status 5

4.3 Replacing the ULB-364 Batteries The batteries in the ULB-364 should be replaced after six months or prior to each use/after each deployment. To change the ULB-364 batteries, follow this procedure: Gently loosen and remove the transducer/pcb assembly from the housing. Figure 4-1 ULB-364 Disassembled Remove the old batteries and install the new batteries. Note the battery terminal orientation before making a connection. Ensure the battery terminals are fully seated. Figure 4-2 ULB-364 Battery Connections Rotate the transponder/pcb assembly and repeat the same steps for the opposite side. Each battery should fit into their respective terminal as shown below: 6

Figure 4-3 ULB-364 Battery Installation Before installing the end cap assembly, make sure the O-ring and O-ring surfaces are clean and free of debris. Lubricate the O-ring with a light coat of silicon grease (O-lube). Reassemble the unit by reversing the order of disassembly. 7