Cole-Parmer Pro-Spense Disposable Syringe Pump User s Manual. Model # (100ml), # (260ml) Publication REV-A

Similar documents
Brine Crystallization Kit Instruction Manual

Effective This guide supersedes all previous versions

Owner s Manual & Safety Instructions

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

Model M120 Mini Temperature/Humidity Meter

Owner s Manual & Safety Instructions

WARNING ELECTRIC PALLET TRUCK EPT Revised A company dedicated to solving ergonomic and material handling problems since 1955.

Model M130 Mini Anemometer

Regal Pipettes INSTRUCTION MANUAL. Serial No. World Precision Instruments

Model 10A. Model 20A. Operating Manual. ECG Simulator. ECG / Arrythmia Simulator

FO-6000 Inline FO Filter Holder FO-6000FILT INSTRUCTION MANUAL. Serial No. World Precision Instruments

Global Water Instrumentation, Inc.

78-RK VARIABLE SPEED HEAVY DUTY VIBRATOR OPERATING MANUAL

Manual No Revision MODEL GLI HAND-HELD/PORTABLE TOTAL/FREE CHLORINE METER

Model E100 Gauss Meter

DIGITAL PLATFORM SCALE

Global Water Instrumentation, Inc.

WeighSouth. WBT Toploader Balance

PINLESS LCD MOISTURE METER WITH TRICOLOR BAR GRAPH USER S MANUAL

Circular Expansion Cement Curing Kit Instruction Manual

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

ENMET Corporation PO Box 979 Ann Arbor, MI GS-24-DF. Manual October 2003 MCN-314, 12/05/03

Lionel Drawbridge Owner s Manual /02

Sby SR Instruments, Inc.

OPERATOR S MANUAL Model 56A Prefeed / Dereeler

Instruction Manual HI Portable ph/ec/tds/ C Meters

MPM-10 Piezo Translator INSTRUCTION MANUAL

LIGHT CONTROLLER LC 500

Breath Simulation Module

7 TFT LCD COLOR REAR VIEW SYSTEM

2200 lb. Semi-Electric Stacker

MTTC User Manual. Innovative Technology for a Connected World. General Description. Specifications and features

WARNING. Introduction ! ATTENTION

Operation Manual. Dual Temperature Digital Dry Block Incubator. Catalog No. INCUBATOR Rev C. April 2016

EP100 EMERGENCY POWER BANK

Basementsaver BP1 & BP2 Battery Backup Sump Pumps Installation

PINLESS LCD MOISTURE METER WITH TRICOLOR BAR GRAPH USER S MANUAL

Innovations. For Life. EXAFLOW EXTERNAL CSF DRAINAGE PRODUCT CATALOGUE

Miniglaze/2. Owner & Operator's Manual PORCELAIN STAINING AND GLAZING FURNACE. Model No: Voltage: V 50/60Hz V 50/60Hz

Pallet Jack 4,400 Lbs Capacity Model #31001

INSTALLATION AND OPERATION MANUAL

User Guide M Rev A 09/15

7 PIECE TUBE FLARING KIT

Waterproof Digital Refractometer , , , , , & Instruction Manual

Installation Guide. Single AC or Dual AC Sump Pump Installation. 1 AC Primary Pump or 2 AC Pumps with Auxiliary Alternator

Global Water Instrumentation, Inc.

Process Returns in VOTW

Safety Precautions. 3. Cabinet Assembly 4. Operating buttons / functions.5-6. Machine Operation

Lionel Cantilever Signal Bridge Owner s Manual

IDA-5. Infusion Device Analyzer. Getting Started

MHGR-32: Manhole Guardrail System

UNI BAR. user manual. ELATION UNI BAR user manual

TA Instruments Packing the DHR Instrument

Cole Parmer Conductivity Meter

EP-VACSEAL OWNER S MANUAL

OPERATOR MANUAL. INDEX page Turning on/off the indicator Weighing Zero weighing Calibration 3

Lionel #213 Lift Bridge Owner s Manual /02

TURBIDOSTAT MODULE TS 1100

Advanced Life Support Basic Life Support Trainer

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features

JETSTREAM TYPE FLUID ENDS

BC Series Compact Counting Scale INSTRUCTION MANUAL

QA-ES Automation Bundle

8 DIAL CALIPER. Model Diagrams within this manual may not be drawn proportionally.

DRS220. DRS220 Digital Refrigerant Scale Limited Warranty. Digital Refrigerant Scale

DMX-BRANCH/4. user manual. ELATION DMX-BRANCH/4 user manual

Tube Revolver. Catalog # & Operation Manual User Manual

HydroLink Watering System with Snake Tubing Installation, Operation & Maintenance Manual

Qualstar Technical Support

Laboratory Refrigerator Model: ,-01,-02,-03,-04,-05,-06,-07,-08, -09,-10,-11,-12,-13,-14

INSTALLATION AND OPERATION MANUAL

Adam Equipment LBH SERIES. (P.N , Revision B2, January 2010)

Q45WQ. Water Quality Monitoring System. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

REF DOC # STANDARD IMAGING, INC Murphy Drive Middleton, WI TEL TEL FAX

Model 292A. Surface Resistance Test Kit. Instruction Manual

Wealtec Corp. E-Centrifuge Microcentrifuge Operation Manual. Version 3.0 Item # *This instrument is intended for laboratory use only

WARNING! Read all of the information in this booklet, and any relevant Application Notes, before using the Eco Sensors DO3.

Global Water Instrumentation, Inc.

Sump Pump System OEM INSTALLATION MANUAL

Turbidity Meter Instruction Manual

AF-3 Speed Controller

Instruction Manual. HI HI Portable ph/ec/tds/ C Meters

VI PARTS LIST. , ELECTRIC FRYER PARTS LIST ITEM DESCRIPTION MODELS PART # 10x x24

Advanced Calibration Designs, Inc.

PROPOSAL FOR MODEL: HP 2100X

Operation Manual INCUBATOR2 Dual Dry Block Incubator

USER'S GUIDE TO OPERATION

CMR Quick Start Guide. CMR-5975 Digicast Media Router (MR-S2) Part Number MN-CMR5975-QSG REV. 3

Calibrate Accessory Actuators Instructions

DICKSON TH8 DICKSON. Temperature & Humidity Chart Recorder Operation. Useful Features. Applications & Product. Specifications. Product.

F-2000H HAY AND HOPS MOISTURE METER. OPERATION MANUAL v3.6 DELMHORST EUROPE TITANIUMLAAN 100 THE NETHERLANDS

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Operator s Manual. Rev C 1/24/ O Neil Rd, Macedon NY Telephone: (315) Fax: (315)

Model Number: 1300 Series

The Biology CRO. Protein Staining System. For electric staining of proteins in mini polyacrylamide gels. Version 1.0 April 3, 2010.

self level laser Model Set up And Operating Instructions

1 TON PORTABLE GANTRY CRANE Model LB. PORTABLE GANTRY CRANE Model 94831

Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches

Global Water globalw.com

VWR Zero Air Generator Models , Installation, Operation, and Maintenance Manual. Bulletin TI-ZAG3500-L1466

Transcription:

Cole-Parmer Pro-Spense Disposable Syringe Pump User s Manual Model #74905-46 (100ml), #74905-47 (260ml) Publication 5607-008-REV-A

Contents Caution...2 Product Purpose and Assembly...2 Specifications...2 Operation...3 Parts and Accessories...4 Limited Warranty...5 1

Caution 1) This product is assigned to be operated by professionals. 2) The controller and the solution box are both disposable and can not be re-used 3) Before opening the solution box package, please examine it carefully. If the package is broken, usage is prohibited. 4) If there is leakage after medical solution has been injected into the box, usage of this product is prohibited. 5) After completing the injection, the product must be disposed according to government rules of disposable medical equipment. CAUTION Refer to Manual Protective Ground Terminal Specifications Power Supply 1.5V battery 2 Reservoir 100 ml or 260 ml Flow Rate 1 ml/h 10 ml/h Flow Setting Option 1, 2, 3, 4, 6, 8, 10 ml Infusion Accuracy ±10% Alarm and Indicator "Low Battery" indicator; "Infusion Completion"/"Error" alarm; "Running" indicator Function 1/4 of preset delivery dosage. P.C.A accuracy is ±10%. The interval between two P.C.A injections is no less than 30 minutes. Operation SYMBOLS 1) This product is internal powered, and is able to continuously working for hours; 2) Type of Protection Against Electric Fig. 1 Shock: TypeBF; 3) Degree of Protection Against Ingress of Fluids: IPX1; 4) Exclamatory mark: Please refer to user s manual. 2

OPERATION PROCEDURE 1) Load syringe, open the package of sterilized reservoir. Inject medication into the box through the linker. (Fig. 2) Then, referring to the air-vent direction on back of the reservoir box, vent air in the reservoir; 2) Close the roller clamp; take off the linker and connect on the extension tubing; now the reservoir is ready. 3) To prepare the controller, install two AA batteries. Please watch carefully the + and - polarities of the batteries. (Fig.3) 4) Turn the Flow Rate Setting Knob, locates on the control panel; set the flow rate to Purge, and then turn on the power switch. While the power is on, indicators Low Battery, Alarm, Run will light with buzzer alarm (Fig.4). Push the P.C.A button, and check whether all the functions on the controller work well; after that shut down the controller immediately; 5) Push the controller into reservoir box (Fig. 4); 6) Turn on the controller again; push P.C.A button to drive air out of the tubing and needle; set the infusion rate; and push Run button to start infusion. 7) During a normal infusion, the green light is flashing intermittently; 8) During a normal infusion, the rate setting switch is locked automatically. If a resetting of the infusion rate is needed, the pump must be rebooted. Fig. 2 Fig. 3 Fig. 4 3

Parts and Accessories PACKAGE AND COMPLETE SET 1) Controller (One piece) 2) Reservoir box (sterilized package) (One piece) 3) AA battery (Two pieces) 4) Disposable tubing (One piece) 5) User s manual (One piece) 6) Product series number, name, brand name; 7) Manufacturer, address, postal code; 8) Product quantity, weight, batch code; 9) Product transportation and storage identifiers 10) Environmental conditions for transportation and storage Order # Model 74905-46 Pro-Spense Portable Disposable Pump, Reservoir 100 ml 74905-47 Pro-Spense Portable Disposable Pump, Reservoir 260 ml 4

Limited Warranty The Cole-Parmer Instrument Company warrants this product to be free from significant deviations in material and workmanship for a period of one year from date of purchase. If repair or adjustment is necessary and has not been the result of abuse or misuse within the one year period, please return-freight prepaid-and correction will be made with-out charge. Cole-Parmer Instrument Company alone will determine if the product problem is due to deviations or customer misuse. Out of warranty products will be repaired on a charge basis. Return of Items Authorization must be obtained from our Customer Satisfaction Department before returning items for any reason. When applying for authorization, please include data regarding the reason the items are to be returned. For your protection, item must be carefully packed to prevent damage in shipment and insured against possible damage or loss. Cole-Parmer Instrument Company will not be responsible for damage resulting from careless or insufficient packing. A restocking charge will be made on all unauthorized returns. NOTE: the Cole-Parmer Instrument Company reserves the right to make improvements in design, construction and appearance of our products without notice. Cole-Parmer Instrument Company 625 East Bunker Court Vernon Hills, Illinois 60061-1844 Ph: 1-847-549-7600 Toll-free 1-800-323-4340 Fax: 1-847-247-2929 Telex: 28-9405 Copyright 2009 by Cole-Parmer Instrument Company. All rights reserved. Printed in USA 5

Notes: 6

Notes: 7

Notes: 8