Energy Audit Summary Report Audit No DE. Märkisch Edel Eberswalde, Germany. Food Industry

Similar documents
Energy Audit Summary Report Audit No. 72. Food Industry Bakery

Energy Audit Summary Report Audit No GER08. DIN Building Berlin, Germany. Offices

Energy Audit Summary Report Audit No. 21. Pharmaceutical Industry

Energy Audit Summary Report. Manufacture of cosmetics

Energy Audit Summary Report. Food Industry

Energy Audit Summary Report. C.I.B. S.r.l. Plastics Industry

Energy Audit Summary Report AEE INTEC Audit no. 15 UK05 Higher Education University Buildings

General data 1. General information notes Statistical and economical data notes

Software and Method. EINSTEIN Methodology and tool for a fast energy assessment

Available online at ScienceDirect. Energy Procedia 48 (2014 )

Energy Efficiency in the Industrial Sector

COGENERATION THE SMART DECISION! Why and how cogeneration can make your company more profitable and energy efficient?

MATHEMATICAL MODELLING AND OPTIMIZATION OF CHP SYSTEMS FOR HOSPITALS IN TURKEY

ALDRON. CHP SOLUTIONS Environmental, Economic & Resiliency Implications NFMT 2015

Heat recovery from industrial installations

The 34 th Congress of Euroheat & Power

Overview of cogeneration technology and application

KWK Modellstadt Berlin

GREENFOODS energy efficiency in the food and beverage industry

Increasing Energy Efficiency in Breweries with Gas Turbine Cogeneration

Heat recovery from diesel engines and gas turbines

Optimization of a Cogeneration System in the Automotive Industry

Gas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings

Combined Heat and Power

Heat recovery from diesel engines and gas turbines

Energetic, Economical Analysis and Avoided CO 2 Emissions in a Cogeneration System Regarding the Legislation

Power Quality Application Guide. Cogeneration

Lecture (5) on. Thermal Power Plant Unit Selection. By Dr. Emad M. Saad. Mechanical Engineering Dept. Faculty of Engineering.

Climate Change is the biggest challenge of today Mankind. Until now, there is not an easy solution

CSP and Natural Gas Hybrids

26 th World Gas Conference

Cogeneration in a Hospital: a case Study

ImprovIng energy efficiency with chp: how to evaluate potential cost savings

BIOMASS CHP. Biomass Cogeneration/Trigeneration. Sustainable and cost-effective solutions for heating, cooling, and electrical power generation using:

Commercial Combined Heat & Power (CHP) Available via Fully Serviced Free to Fit, Cash, Leasing or Finance

Exploring a University Based Microgrid

Digester Gas Utilization at SWRP Where Should the Biogas Go?

Boiler & Heater Group

Efficiency Maine Symposium Combined Heat & Power Portland, ME. Dan Kelley-Vice President. & Service Line Leader Portland, ME

Small Scale CHP Using the Organic Rankine Cycle

Heat recovery from diesel engines and gas turbines

DP&L Business Rebate Programs June 27, Lyle Garrison EE Program Manager

Funded by: European Eur Union 1

6 Cost Analysis. Table 6.1 Initial System Costs

Björn Kjellström Exergetics AB, Sweden

Integrated Production of Power Cooling and Water Jürgen Scharfe

Payback period of renewable and efficient energy technologies at buildings

Simposio Internacional Oportunidades de Eficiencia Energética en el Sector Agro-Alimentario. 7 de Octubre Centro Español San Fernando

Arrow Linen: CHP Washes Away Energy Costs of Commercial Laundry

Syllabus Cogeneration: Definition, Need, Application, Advantages, Classification, Saving potentials

Economics of Distributed Resources

Process Optimisation of Brewery Plant with Biogas fired CHP/Trigeneration

Bringing energy and the environment into harmony. your savings on chp will be reflected everywhere.

Presentation. Renewable Project of the Year Old Oak Common Crossrail Depot. Tony Amis Business Development Director 20 th October 2016

Environment & Power Systems International. VOCGEN /CHP Feasibility Screening Data Form. Level 1 Feasibility Analysis

Biomass CHP Systems using Organic Rankine Cycle from Europe to North America

Low temperature cogeneration using waste heat from research reactor as a source for heat pump

Energy efficiency improvement in bakeries and confectioneries HOW TO REDUCE ENERGY COSTS. Guide for Entrepreneurs

Enhancing Energy Efficiency in Dairies. Mr. Anshuman Pandey, Lead Application Engineer OPRA Turbines International B.V

Gas Turbine Inlet Air Cooling System

The Benefits of Cogeneration Case Study: Upper Chesapeake Medical Center

Feed-Water Repowering in Besat Power Plant: Technical and Costing Aspects

LARGE SCALE TRIGENERATION AND DISTRICT HEATING AND COOLING WITH RENEWABLE CONCEPTS WITHIN THE SPANISH POLYCITY PROJECT

SOLAR PROCESS HEAT FOR SUSTAINABLE AUTOMOBILE MANUFACTURING - SYNERGIES OF A STRONG COOPERATION

Biogas Heating Networks

Twinning project Bulgaria

1 st Renewable Energy Technologies, LP. Organic Rankine Cycle

Energy Ideas for Galvanizing

REEEP GROUP SDN. BHD. (Company No.: D)

COMBINED HEAT AND POWER by KARA

ST-4 Polygeneration plant. Parc de l Alba Cerdanyola del Vallès

A comparison of advanced thermal cycles suitable for upgrading existing power plant

Energy consulting for industrial clients - current data analytic methods Examples in food & beverage Michael Tenner, May 9 th 2017, Chicago

London 2012: Energy & Sustainability at the Olympics 3 rd July 2012

Roberto Bini Turboden srl Brescia I Fabio Viscuso Turboden srl Brescia -I. cod. 11-A-858-rev.0

Explanation of JCM Feasibility Study in Thailand & Applicable Low CO2 Emission Technology

Energize your profits Discover hidden assets WASTE HEAT RECOVERY

Technical And Economical Aspects Of Thermal Efficiency Of Grate-Fired Waste-To- Energy Plants

Heat Recovery. Integrated CHP Systems Corp.

Sometimes Being Faced With A Challenge Can Lead To Greater Opportunities

Gainesville Regional Utilities: Reciprocating Engine CHP

REPORT REDUBAR WP02 D02 EIE/06/221/SI

Gensets and cogeneration

Challenges in Industrial Waste Heat Recovery. Texas Technology 2006 Showcase Tony Dafft December 6 & 7, 2006

Energy Efficiency in Public Buildings through Energy Services The example of Germany

Overview of Cogeneration Technologies and Applications

Termotecnica Pompe di Industriale. Gli atti dei convegni e più di contenuti su

The Use of Biomass in District Heating and Cooling Systems

CODE2 Cogeneration Observatory and Dissemination Europe. D2.1 CHP Awareness Case Study GREECE

Combined Cooling, Heating and Power (CCHP) in Distributed Generation (DG)

BİLBAO AIRPORT COGENERATION

Cogeneration a.k.a. Combined Heat & Power (CHP) Overview

Potential of Process Integration in four Industrial Companies in Germany

ORC Technology for waste Heat Recovery Power Generation. Dr Vijayakumar Kunche, M.Tech., Ph.D.

Deliverable 3.a (Combining former deliverables 3.1; 3.2; 3.5)

University of Illinois at Chicago East Campus

Overview of Cogeneration Technologies and Applications

Rank. Rank Technology.

Welcome / Bienvenue. RETScreen Training Institute RETScreen 101 Introduction to Clean Energy Project Analysis

DESIGN SUSTAINABLE BUILDING WITH OPTIMIZED COMBINED HEATING, COOLING, AND POWER (CHCP) SYSTEM

Transcription:

Energy Audit Summary Report Audit No. 48 - DE Märkisch Edel Eberswalde, Germany Food Industry Industrial bakery energyxperts.net Berlin (Germany) / Barcelona (Spain) March 2012

This energy audit has been carried out with cofunding of the European Commission (EACI) in the Framework of the EU funded project EINSTEIN-II (ProjectNo. IEE/09/702/SI2.558239) 39) 2

1. Contact data of the auditors Hans Schweiger, Claudia Vannoni, Cristina Ricart energyxperts.net, Barcelona (Spain) - Berlin (Germany) www.energyxperts.net info@energyxperts.net 3

2. Description of the company (status quo) EINSTEIN Audit Summary Report Reference year of data/information: 2010 (Date of the visit on site: 18.04.2011) 2.1. General information of the company Company, location Sector Products Märkisch Edel, Eberswalde (Germany) industrial bakery bread (full baked and half-baked), cakes Yearly production about 2884 t (bread: 2628 t) Turnover No. of employees Current final energy consumption [MWh] (*) n.a. n.a. total for heating and cooling - gas oil 1.908 1.908 - electricity 723 211 (*) fuel consumption in terms of MWh lower calorific value (LCV) (a) (b) Figure 1. (a) General view of the production hall; (b) Sales shop. 4

2.2. Description of the company a) Productive process The company Eberswalder Brot- und Feinbackwaren produces the whole sortiment of baked products, producing bread, bread rolls, cakes, pastries, and confectionery. The dough is either fully baked in the plant, or prepared as (cooled dough or half-baked and then frozen) raw product and then fully baked in the electrical ovens in the sales shops 1. (a) (b) Figure 2. Ovens (a) continous (Henff-) oven; (b) Stikken-ovens Figure 3. Simplified production flow sheet. The most energy consuming processes in the company are the ovens (almost 70 % of the heating demand including steam injection) 1 Energy consumption of sales shops not included in the analysis. 5

b) Energy supply system The heat used for the ovens is generated in a gas-oil fired thermal oil boiler, and then from this thermal oil circuit steam is generated for vapour injection into the ovens. The five smaller Stikken-ovens are direct fired. Hot water and space heating for offices and the production hall is generated in a separate hot water boiler, and the workshop of the company disposes of an independent boiler. Cooling for the different cooling chambers is provided by different air-cooled electrically driven chillers. (a) (b) Figure 4. (a) thermal oil boiler; (b) steam generator driven by thermal oil 6

Figure 5. Overview of the heat and cold supply system 2.3. Additional comments The distribution of the heat demand in the company on the different processes is approximate, based on the available data on product flows and estimated ratios of consumption. 7

3. Comparative study of alternative proposals EINSTEIN Audit Summary Report A comparative study of several technically feasible alternative proposals for energy saving has been carried out. In the following sections the alternatives are first shortly described and then the results of the comparative study are presented. 3.1. Proposed alternatives The technical potential alternatives that have been investigated are listed in Table 1. Table 1. Overview of the alternative proposals studied. Short Name Description WRG KWK Heat recovery (Wärmerückgewinnung): 3 heat exchangers for recovery of heat from vapour of ovens (Schwaden, 30 kw), from waste water of the box washer (7 kw) and from the exhaust gas of the thermal oil boiler (21 kw) for preheating of water and space heating. Cogeneration (Kraft-Wärme-Kopplung): Gasturbine of 100 kwe / 188 kwth for heating of ovens, generation of steam, hot water demands and space heating. (includes also the heat exchanger network from alternative WRG) 3.2. Energy performance 2 Table 2. Comparative study: yearly primary energy consumption. Alternative Present State (checked) Primary energy consumption [MWh] Savings [MWh] [%] 4.052 --- --- WRG 3.578 474 11,70 KWK 3.065 987 24,36 2 The factors for conversion of final energy (for fuels in terms of LCV) to primary energy used in this study are 2,7for electricity and 1,1 for gas oil and natural gas. 8

4.500 4.000 Primary energy consumption (MWh) 3.500 3.000 2.500 2.000 1.500 1.000 500 0 Present State (checked) WRG KWK Figure 6. Comparative study: yearly primary energy consumption. 3.3. Economic performance Table 3. Comparative study: investment costs. Estimated co-funding: 10 % for investment in heat recovery and CHP. Alternative Total investment Own investment Subsidies [ ] [ ] [ ] Present State (checked) --- --- --- WRG 20.000 18.000 2.000 KWK 220.000 198.000 22.000 9

250.000 Own investment Subsidies 200.000 Investment Costs [ ] 150.000 100.000 50.000 0 Present State (checked) WRG KWK Figure 7. Comparative study: investment costs. Estimated co-funding: 10 % for investment in heat recovery and CHP. Table 4. Comparative study: annual costs including annuity of initial investment 3. The energy cost for CHP includes also the feed-in-tariff revenue for the CHP electricity of 21 /MWh. Alternative Annuity Energy Cost O&M Total [ ] [ ] [ ] [ ] Present State (checked) --- 201.297 0 201.297 WRG 2.059 176.186 1.600 179.846 KWK 22.652 114.935 7.650 145.237 3 Annuity of initial investment: 10,3 % of yearly payments, calculated based on 8 % nominal interest for external financing, 2 % general inflation rate and 15 years of economic depreciation period. Tariffs (estimated): 60 /MWh for gas oil, 40 /MWh for natural gas, 120 /MWh a for purchased electricity, 141 /MWh for sold electricity (feed-in prime of 21 /MWh). 10

250.000 Annuity Energy Cost O&M 200.000 Total Yearly Costs [ ] 150.000 100.000 50.000 0 Present State (checked) WRG KWK Figure 8. Comparative study: annual costs including annuity of initial investment (see Table 4). 4. Selected alternative and conclusions 4.1. Selected alternative The alternative proposal KWK (cogeneration) that combines a customized heat exchanger network and a cogenerative gas turbine of 100 kw e / 188 kw th has been considered the best option among the previously analysed due to the following reasons: higher potential of both primary energy and energy cost savings very good economic performance In the following sections, the selected alternative is described in detail. 4.1.1. Process optimisation The possibility of process optimisation has not been considered in this study as the information available on the existent equipment and on potential alternative technologies is not sufficient in order to carry out this assessment. Nevertheless this might be checked in the future, best before implementing the recommended measures. 11

4.1.2. Heat recovery The proposed heat exchanger network consists of 3 heat exchangers for recovery of heat from vapour of ovens (Schwaden, 30 kw), from waste water of the box washer (7 kw) and from the exhaust gas of the thermal oil boiler (21 kw) for preheating of water and space heating (Table 5). As can be seen from Table 2, heat recovery leads to a saving of 11,7 % of the primary energy consumption. Table 5. List of heat exchangers proposed. Heat Exchanger Power Heat Source Heat Sink Amount of recovered energy HX Vapour ovens Box washer HX Vapour ovens Production water HX Box washer Sanitary HW HX Offgas Space Heating and HW [kw] [MWh] [%] 7 Vapour ovens Box washer 35 11,32 23 Vapour ovens Production hot water 151 48,62 7 Waste water box washers Sanitary hot water 22 7,06 21 Thermal oil boiler (exhaust gas) Hot water and space heating 102 33,00 59 310,47 100 12

4.1.3. Heat and Cold Supply In the new system proposed a cogeneration plant (gas turbine) is added to the heat supply system. The CHP plant feeds heat into distribution for hot water and space heating. In addition, from the hot exhaust gas of the turbine steam is generated for the injection in the ovens, and a direct heating of the ovens is carried out. Table 6. Heat and cooling supply equipments. Selected alternative. Heat / cooling supplied to Equipment Type Nominal capacity pipe/duct Contribution to total heat / cooling supply New CHP 2 CHP gas turbine o==thermoöl (thermal oil)==o o==direktheizung==o o==dampfleitung==o o==warmwasser u Heizung==o o==heizung Werkstatt==o [kw] [MWh] [%] 188 850 48,92 Thermoölkessel (thermal oil boiler) steam boiler o==thermoöl (thermal oil)==o o==dampfleitung==o 500 307 17,69 Brenner Stikkenöfen (Burners) Heisswasserkessel (hot water boiler) steam boiler hot water boiler o==direktheizung==o o==warmwasser u Heizung==o 390 91 5,21 70 43 2,50 Heizung Werkstatt hot water boiler o==heizung Werkstatt==o 18 5 0,30 Kälteanlagen compression chiller (air cooled) o==kühlkammern==o 101 441 25,38 The technical specifications of the new CHP turbine are given in Table 7. Table 7. Technical specifications and economics of the new CHP gas turbine. Parameter Units Technical data Type of equipment - CHP gas turbine Nominal power (heat or cold output) kw 187,50 Fuel type - Natural gas Electrical power generated (CHP) kw 100,00 Electrical conversion efficiency (CHP) - 0,30 Parameter Units Data Turn-key price 260000,00 Annual operational and maintenance fixed costs 1800,00 Annual operation and maintenance variable costs dependant on usage /MWh 5,00 13

The total and monthly contribution of the new equipments to the total heat supply is shown respectively in Table 8, Figure 9 and Figure 10 while the contribution to the cooling supply is shown in Table 9. Table 8. Contribution of the different equipments to the total useful heat supply (USH) in the company. Equipment USH by equipment [MWh] [% of Total] Thermoölkessel (thermal oil boiler) Brenner Stikkenöfen (Burners) Heisswasserkessel (hot water boiler) Heizung Werkstatt New CHP 2 307 23,70 91 6,99 43 3,35 5 0,40 850 65,56 Total 1.297 100 Figure 9. Contribution of the different equipments to the total useful heat supply (USH) in the company. 14

160 New CHP 2 Thermoölkessel (thermal oil boiler) Brenner Stikkenöfen (Burners) Heisswasserkessel (hot water boiler) 140 Heizung Werkstatt 120 [MWh/month] 100 80 60 40 20 0 February January March April May June July August October December September November Figure 10. Contribution of the different equipments to the total useful cooling supply (USH) per month. Table 9. Contribution of the different equipments to the total useful cooling upply (USC) in the company. Estimated data; no breakdown available for different temperature levels / processes. Equipment USC by equipment [MWh] [% of Total] Kälteanlagen 441 100,00 Total 441 100 15

4.2. Summary: saving potential with respect to present state and economic performance The following measures are proposed: heat recovery: use of waste heat from vapours (ovens), waste water (box washer) and exhaust gas (thermal oil boiler) for preheating of water and space heating cogeneration (gas turbine) for covering the base load of the remaining heat demand These measures allow to save 24 % of the current total primary energy consumption and 43 % of current energy cost. The total required investment is about 220.000 and the expected pay-back time is 2,7 years (considering possible subsidies). Table 10. Comparison of the present state and the proposed alternative: saving potential and economic performance. Total primary energy consumption (1) U.M. Present state Alternative Saving - total MWh 4.052 3.065 24,36% - fuels MWh 2.099 2.655-24,57% - electricity MWh 1.953 450 76,94% Primary energy saving due to renewable energy MWh 0 0 - CO 2 emissions t/a 839 678 19,21% Annual energy system cost (2) EUR 201.297 145.237 27,85% Total investment costs (3) EUR - 220.000 - Payback period (4) years - 2,7 - (1) including primary energy consumption for non-thermal uses (2) including energy cost (fuel and electricity bills), operation and maintenance costs and annuity of total investment. It also includes the feed-in-tariff revenue for the electricity produced by the CHP plant and sold to the net. (3) total investment excluding subsidies. (4) supposing 10% of funding of total investment (subsidies or equivalent other support mechanisms) 16