ISSN X CODEN (USA): PCHHAX

Similar documents
A Simple Rapid and Sensitive Method Development for Quantification of Quetiapine Fumarate in Bulk and Dosage Forms Using RP-HPLC

P. Wadhwani College of Pharmacy, Yavatmal , India. *Corres.author: Cell No

10. Validated Normal Phase HPLC Method for the Determination. Fulvestrant is primarily used in the treatment of hormone receptor

Journal of Pharmaceutical and Bioanalytical Science

Application Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau

ISSN India; g,secunderabad. Abstractt. a flow rate. of 1ml/min. di hydrogen. which acts. and chronic. including minimize (5) Figure

International Journal of Pharma Research and Health Sciences. Available online at

Development and Validation of Isoniazid in Bulk and Pharmaceutical Dosage Forms by UFLC Method

Automated QbD-Based Method Development and Validation of Oxidative Degraded Atorvastatin

Automated Method Development With UPLC and Fusion Software A Quality by Design-based Tool Jean-Michel Plankeele May Waters Corporation 1

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

Lakshmana Rao et.al Indian Journal of Research in Pharmacy and Biotechnology ISSN: (Print) ISSN: (Online)

Quantitative determination of residual 2-(2-chloroethoxy) ethanol (CEE) in quetiapine fumarate by gas chromatogaraphy

Validation of Analytical Methods used for the Characterization, Physicochemical and Functional Analysis and of Biopharmaceuticals.

9/2/2014. USP Monograph Modernization. Todays topics. USP basic. Todays topics. - USP basic. - USP publications. - USP monograph modernization

DEVELOPMENT AND VALIDATION OF ANALYTICAL METHOD FOR ASSAY DETERMINATION OF ISOSULFAN BLUE BY LIQUID CHROMATOGRAPHY

Quantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 1200 Series RRLC and 6410B Triple Quadrupole LC/MS

Impurity Control in the European Pharmacopoeia

RP-HPLC Method for the Simultaneous Estimation of Lamivudine and Abacavir Sulphate in Tablet Dosage Form

Usharani Gundala* 1, Chandrashekar Bonagiri 2, Devanna Nayakanti 3

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

Development and validation of stability indicating RP-HPLC method for the estimation of Daclatasvir in bulk and formulation

Peptide Mapping: A Quality by Design (QbD) Approach

Emulation of the Agilent 1100 Series LC Through Waters Empower Software Analysis of an Analgesic Mixture

Analysis of amoxicillin and five impurities on the Agilent 1220 Infinity LC System

International Journal of Institutional Pharmacy and Life Sciences 6(5): September-October 2016

IAJPS 2017, 4 (07), P. Hari Sravanth Reddy et al ISSN

QbD approach for analytical method development of anti-pschotic drug

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

International Journal of Pharma Research & Review, Feb 2014; 3(2):11-16 ISSN:

GUIDANCE NOTES ON ANALYTICAL METHOD VALIDATION

Analytical Method Development and Validation for the Estimation of Abiraterone and its Impurity in Pharmaceutical Formulation By RP-HPLC

CHAPTER-3. Zolmitriptan

Simultaneous Estimation of Finasteride and Tamsulosin Hydrochloride in Combined Dosage Forms by RP-HPLC-PDA Method

VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY *)

Research Paper Development of Stability Indicating Reverse Phase HPLC Method for Aripiprazole from Solid Dosage form

Performance characteristics of the 1260 Infinity Quaternary LC system

THESIS SUBMITTED TO THE ANDHRA UNIVERSITY IN PARTIAL FULFILMENT FOR THE AWARD OF THE DEGREE OF DOCTOR OF PHILOSOPHY IN PHARMACEUTICAL SCIENCES

Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC

A green HPLC technique with a 100% water mobile phase for detecting imidacloprid and its metabolite 6-chloronicotinic acid

A Comprehensive Workflow to Optimize and Execute Protein Aggregate Studies

DIDANOSINE ORAL POWDER Final text for addition to The International Pharmacopoeia

Short Communication Stability Indicating Assay Method Development and Validation of Tolteridone Tartrate in Bulk Drug and Capsules

Validated Stability-indicating assay method for determination of Ilaprazole in bulk drug and tablets by high performance liquid chromatography

ISSN: X CODEN: IJPTFI Available Online through Research Article

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Quantitatitive Analysis of Phosphorothioate Oligonucleotide in Human Plasma Using LC-MS/MS with On-Line Extraction

Available Online through (or) IJPBS Volume 2 Issue 3 JULY-SEPT Research Article Pharmaceutical Sciences

Quality by Design (QbD) Based Development of a Stability Indicating HPLC Method for Drug and Impurities

Method Transfer from an Agilent 1200 Series LC to an Agilent 1260 Infinity II LC

High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns

International Journal of Applied Pharmaceutical Sciences and Research

á1225ñ VALIDATION OF COMPENDIAL PROCEDURES

VICH Topic GL2 (Validation: Methodology) GUIDELINE ON VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY

Performance Characteristics of the Agilent 1220 Infinity Gradient LC system

Validation of a Dual Wavelength Size Exclusion HPLC Method with Improved Sensitivity to Detect Aggregates of a Monoclonal Antibody Biotherapeutic

Method development and validation for the quantitative estimation of cefixime and ofloxacin in Pharmaceutical preparation by RP- HPLC

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

INTERNATIONAL RESEARCH JOURNAL OF PHARMACY

DEVELOPMENT AND VALIDATION OF A STABILITY- INDICATING RP-HPLC METHOD FOR THE ESTIMATION OF ERLOTINIB IMPURITIES BY QbD APPROACH

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

CHAPTER III STABILITY INDICATING ASSAY AND IMPURITIES METHODS FOR FIXED DOSE COMBINATION PRODUCT OF OMEPRAZOLE AND DOMPERIDONE

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

STUDYING THE ACCELERATED PHOTOSTABILITY OF CIPROFLOXACIN AND LOMEFLOXACIN IN TABLETS AND EYE DROPS

Chromatography 2015, 36, Technical Note

Intercontinental journal of pharmaceutical Investigations and Research

Application Note. Author. Abstract. Pharmaceuticals. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Developing Quantitative UPLC Assays with UV

STABILITY STUDIES OF RIBAVIRIN SYRUP

NISTmAb characterization with a high-performance RP chromatography column

RESEARCH ARTICLE STABILITY INDICATING ANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF AVANAFIL IN PHARMACEUTICAL DOSAGE FORM

Phase Appropriate Method Validation

Improved Sensitivity with the Agilent 1290 Infinity Evaporative Light Scattering Detector (ELSD)

Application Note. Author. Abstract. Small Molecule Pharmaceuticals. Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany

Saudi Journal of Medical and Pharmaceutical Sciences

Case Study on Application of Analytical Life Cycle Management and Risk Management

Thank You to United States Pharmacopeia for Their Sponsorship and Assistance

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER

Simplifying Methods Transfer: Novel Tools for Replicating Your Established Methods on an ACQUITY Arc System

Seamless Method Transfer from an Agilent 1260 Infinity Bio-inert LC to an Agilent 1260 Infinity II Bio-inert LC

International Journal of ChemTech Research CODEN (USA): IJCRGG, ISSN: , ISSN(Online): Vol.10 No.6, pp , 2017

Solubility Enhancement of Candesartan Cilexetil by Mixed Solvency Approach

IJSER. (2E)-2-cyano-3-(3,4-dihydroxy-5-nitrophenyl)-N,N-diethylprop-2-enamide [Entacapone] 7

CRITICAL ASPECT ANALYTICAL TEST REVIEW

Journal of Pharmaceutical and Biomedical Analysis Letters. Analysis Letters

Development of Stability-Indicating UHPLC Method for the Quantitative Determination of Silodosin and Its Related Substances

AdvancedTools in HPLC methoddevelopment

AdvanceBio HIC: a Hydrophobic HPLC Column for Monoclonal Antibody (mab) Variant Analysis

Application Note. Authors. Abstract. Biopharmaceuticals

ACQUITY Arc TM System

The concept of quality by design

MANOHAR C. SONANIS 1,2, A.P RAJPUT 1 *

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

Validation of Analytical Method of Irbesartan Plasma in Vitro by High Performance Liquid Chromatography-Fluorescence

Fusion Analytical Method Validation

Application of Quality by Design (QbD) in product development. James E. Polli September 16, 2015

Sean M. McCarthy and Martin Gilar Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL RESULTS AND DISCUSSION

SIMPLE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR DETERMINATION OF NORFLOXACIN IN PLASMA AND APPLICATION IN BIOEQUIVALENCE STUDY

Online UPLC Method for the Support of Cleaning Validation and the Routine Monitoring of Cleaning Procedures

Transcription:

Available online at www.derpharmachemica.com ISSN 0975-413X CODEN (USA): PCHHAX Der Pharma Chemica, 2016, 8(1):282-288 (http://derpharmachemica.com/archive.html) Quality by Design (QbD) approach towards the development and validation of HPLC method for Gentamicin content in biodegradable implants Shrikant Patil 1, Kari Vijayakrishna*,1 and Jaiprakash Sangshetti 2 1 Organic Chemistry Division, School of Advanced Sciences, VIT University, Vellore, Tamil Nadu, India 2 Pharmaceutical Chemistry Division, Y B Chavan College of Pharmcy, Aurangabad, Maharashtra, India ABSTRACT A High performance liquid chromatography (HPLC) method for quantitative analysis of Gentamicin is developed using a Quality by Design (QbD) a statistical approach. Gentamicin Sulphate is broad spectrum antibiotic aminoglycoside drug. It is used to treat infections and inflammatory diseases caused by susceptible organisms. Due to regulatory needs QbD has gain magnitude. Foremost target profile is determined and then qualification of instrument is done prior to initiation of actual study. Chromatographic separation is achieved on a C-18 column (250 4.6mm, 5micron). The mobile phase used is isocratic elution system consisting of methanol and 15mM di ammonium hydrogen phosphate buffer (ph 10.00) in the ratio 70:30 v/v. In development of HPLC method factors like flow rate, mobile phase composition, column temperature and wavelengths are critical to maintain. Hence Plackett Burman design was used as screening model. Further Box Behnken model was applied as optimization model for the interaction and quadratic effects of three factors namely temperature of the column, flow rate, and wavelength on the selected responses. Effect of these parameters is studied on USP tailing (response). Tailing less than 1.2 was considered as desirable. Results are analyzed using surface diagrams. Verification of the software generated result is done by taking six replicates of the run. Finally the method was validated as per ICH Q2 guidelines. QbD approach is successfully applied for HPLC assay method development of the Gentamicin sulphate. Keywords: QbD, HPLC, Gentamicin, Box Behnken design, Plackett Burman design. INTRODUCTION The aminoglycoside antibiotic Gentamicin has a broad spectrum activity against both the gram positive and gram negative bacterial infections [1]. It is originally obtained from the micro-organism Micromonospora purpurea by fermentation process and is commercially available in different forms of medicine to combat different bacterial infections in humans and cattle [2-5].Gentamicin is highly water soluble, highly polar, and non-volatile and lacks a UV chromatophore. These physical and chemical properties of Gentamicin are a major challenge to retain and separate them through RP-HPLC method. There are different direct and indirect HPLC methods reported in the literature so far for the detection of Gentamicin [5-27].The direct methods comprise refractive index (RI) detection [6], Evaporative Light Scattering Detection (ELSD) [7, 8], Electrochemical Detection (ECD) [9-11], charged aerosol detection (CAD) [12] and mass spectrometry [13-14] and the indirect methods comprise either pre- or post-column derivatization [15-20]. All the above methods have their own advantages as well as limitations such as incompatibility of RI detection with gradient methods, cumbersomeness of pre-column derivatization method and chance of electrode poisoning and very high sensitivity in ECD method. Though there are various HPLC methods available in the literature, they are time consuming and costly for routine analysis of sample. As per ICH Q8 (International Conference on Harmonisation of Quality 8), Quality by design (QbD) is a systematic approach to pharmaceutical method development that begins with predefined objectives and emphasizes product, process understanding and process control based on sound science and quality risk management [27]. Development of various HPLC methods for the analysis of drug substances and drug products using QbD approach are widely 282

reported in the literature [28-42]. In this paper, we discuss the detection and separation of Gentamicin (sulphate) for the first time in biodegradable implants by RP-HPLC method through QbD approach. This method is simple, reliable, cost-effective, selective, sensitive and robust. Plackett Burman design was used for screening of factors which affect response and the factors that have significant effect on response were selected for optimization by Box Behnken experimental design. MATERIALS AND METHODS All the organic solvents used for experimentation were of HPLC grade. Chromatography grade methanol (%) and diammonium phosphate (%) were purchased from Merck Millipore. All the aqueous solutions were prepared using Milli-Q water. Reference standard of Gentamicin was obtained from Food, Drugs and Chemicals (FDC) Limited, Aurangabad, Maharashtra, India. Instrumentation and the chromatographic conditions RP-HPLC of Gentamicin was analyzed using Agilent HPLC system equipped with PU 2089 quaternary gradient pump, UV-2075 plus detector, LC-Net II/ADC communication module and chromatographic separation was achieved on X-Terra RP C-18 column (150 x 4.6mm, 5 µm packing). Data analysis was carried out using Empower 2 software build 2154 SPs version 1.8.6.1. The gradient elution system consisting of methanol and 0.01m diammonium hydrogen phosphate buffer was used as mobile phase. Here the proportion of mobile phase was changed based on the experimental design. Extraction of Gentamicin from Implants Gentamicin from polymer based implants was extracted via liquid-liquid extraction technique using water-dcm (Dichloromethane) as a solvent mixture. Gentamicin is freely soluble in water and insoluble in DCM. But remaining polymer blend was miscible in DCM. Triplicate washing was given to the DCM extract. Sample concentration was made as accordingly. Gentamicin sample preparation A stock solution of 10mg/mL Gentamicin was prepared in water and then, different concentrations of 250-10,000 ppm were prepared by serial dilution method. Analytical target profile The target profile is a prospective summary of the quality characteristics of a drug product that will be ideally achieved to ensure the desired quality and standard [27]. Here, the main aim of the RP-HPLC method of Gentamicin is to be robust, sensitive, accurate and precise with USP tailing less than 1.3, analysis time less than 10 min. A robust method should be developed with the help of visualizing a design space as per the QbD norms. Risk assessment Here, Pareto analysis is studied for said method by software generated results (Figure 1). In Pareto chart, 6 dummy factors can be seen which are not real factors and any changes in those factors do not affect the system and response. Method design Screening designs are used to sort out the most significant factors from the potentially influencing factors which greatly affect responses. They are applied in the circumstance of optimizing separation techniques during screening, testing of robustness and in the context of optimizing formulations, products or method. Here, Plackett Burman design was used to find significant factors affecting the response [43-45]. For that three level designs was applied for five factors that are flow rate, injection volume, column oven temperature, detection wavelength, and methanol concentration in mobile phase. Experimental conditions are given in Table 1. Table 1: The response variables for Chromatographic factors in Plackett Burman experimental design of Gentamicin Sr.No. Chromatographic factors Level used Low High A Flow rate (ml/min) 0.4 0.8 B Detection wavelength (nm) 255 259 C Column temperature ( C) 38 42 D Injection volume (µl) 38 42 E Methanol concentration (%) 25 35 For optimization response surface methodology was used with five runs of centre point (Table 2). Factors selected were injection volume, column temperature and detection wavelength and the results of Plackett Burman design 283

helped to sort these factors. Evaluations of main factors and their two factor interaction on peak USP tailing factor were done. Injection volume and methanol concentration were kept constant at 40 C and 30 % respectively. Table 2: Three levels for Box Behnken of three factors Chromatographic conditions Level used Low Centre High Flow rate (ml/min) 0.3 0.6 0.9 Wavelength (X3) (nm) 254 257 260 Column temperature (X2 )( C) 37 40 43 Experiments were conducted by making runs of the standard Gentamicin solution in HPLC and the average of USP tailing (Fig 3). It was analysed using Design Expert 8 software and the application of two factor interaction analysis fitted well for the model. Y = β0 + β1x1 + β2x2 + β3x3 + β12x1x2 + β13x1x3 + β23x2x3, where Y is the response, β0 is the arithmetic mean response, β1, β2 and β3 are regression coefficients of the factors X1, X2 and X3, respectively. β12, β13, β23 are interaction coefficients [43-45]. Table 3: Box Behnken design used for study Run Coded (X1, X2, X3) Injection volume(µl) Column temperature ( C) Wavelength (nm) 1 +0+ 0.9 257 43 2 0-+ 0.6 254 43 3 000 0.6 257 40 4 0+- 0.6 260 37 5 ++0 0.9 260 40 6 000 0.6 257 40 7-0+ 0.3 257 43 8 --0 0.3 254 40 9 00-0.9 257 37 10 +-0 0.9 254 40 11-0+ 0.3 257 37 12 0++ 0.6 260 43 13 000 0.6 257 40 14 000 0.6 257 40 15 0-- 0.6 254 37 16 000 0.6 257 40 17 -+0 0.3 260 40 (Where + indicates the high value, - indicates lower value and 0 is the centre) Critical Quality Attributes (CQA) CQA can be set from risk assessment by Pareto analysis as given in ICH Q9 guideline [30]. A critical factor which affects the tailing was determined. Factors such as flow rate, column temperature, and detection wavelength were found to be critical. Validation As per International Conference on Harmonization of analytical validation (ICH Q2) guidelines, linearity, range, accuracy, precision, and robustness of the optimized chromatographic method was validated [44]. For system suitability, standard solution of 500 µg/ml of Gentamicin in water was prepared. Before sample analysis six replicate standard solutions were analyzed. The acceptance criteria for Gentamicin was than 2% relative standard deviation (RSD) for peak area, retention time, symmetry and USP tailing factor less than 2. Linearity Standard calibration curves were prepared with six different concentrations in the range of 250-1000 µg/ml. By injecting each concentration in triplicate, linearity of Gentamicin over the concentration range was determined. Linear calibration curves of drug concentration versus peak area were plotted using linear least squares regression and evaluated for linearity. Accuracy and precision Accuracy and precision of the method were evaluated for Gentamicin by analyzing standard samples prepared from stock solution. As a part of validation and quality control, three replicates each of high (5000µg/mL), intermediate (1000µg/mL) and low (250µg/mL) concentrated standards were analyzed for three consecutive days. Accuracy and precision were determined by analyzing the average, RSD of the peak areas and their resultant concentrations. An acceptance criterion for the precision is that the relative standard deviation of the standards should not be more than 2%. 284

Robustness The robustness of an analytical procedure is a measure of its capacity to remain unaffected by small, but deliberate variations in method parameters and provides an indication of its reliability during normal usage. An analysis should be reliable with respect to deliberate variations in method parameters such as wavelength (+ 2 nm), column temperature (+ 2 C) and flow rate (+ 0.2 ml/min). RESULTS Mobile phase combination also has to be considered while the optimization of retention time and then separation was carried on: X-terra RP C18 column (250 x 4.6mm, 5 µmpacking) with mobile phase of 15mM diammonium phosphate buffer: MeOH at 70:30 v/v ratio and ph value of 10.00. Peak was obtained at retention time of 5.4 min, at flow rate of 0.6 ml/min and column oven temperature of 40 C. Further optimization was done by carrying runs as by Box-Behnken model. Five factors were analyzed by Plackett Burman design and the significant factors were pointed out for the optimization of method factors such as wavelength, column temperature and flow rate. Multivariate regression analysis was applied and fitted two factor interaction model was obtained for the USP tailing factor of peak. Regression analysis and p-values were obtained from the software as shown in Table 4.The analysis of variance (ANOVA) and the effect of interaction terms on the USP tailing of the peak were studied to note the significance of the factors. The p-values supported to assert that the results as statistically significant by convention and p<0.05. DISCUSSION A value of prob>f of the model and was less than 0.05, hence model was found to be significant, (prob>f = 0.0056). Model used was accurate with R2 of 0.892 and a lack of fit was not found to be statistically significant. Significant factors found were wavelength (p-value 0.0035), column temperature (p-value 0.0079) and interaction of flow rate vs. wavelength (p-value 0.0197). An inverse relationship has been noticed for the plot of flow rate and wavelength vs. tailing. The response surface and counter plot were studied and plotted in 3-D graph format as given in Figure2. The effect of wavelength and flow rate on tailing was clearly noticed from the graph as shown in figure 2a where tailing was found to increase at higher wavelength (257 nm) and decrease at lower wavelength and was optimum at flow rate of 0.8-0.9. Also, the effect of column oven temperature and flow rate on tailing was studied from the plot figure 2b where tailing was less at column temperature 38-39 C, within the limit at 37-40 C and out of specified limit above wavelength 257 nm as shown in figure 2c. The critical response was set to minimize tailing below target value of 1.3.The optimum condition chosen from the obtained runs were 257nm wavelength, 0.9 ml/min flow rate, 37 C column temperature and 1.17 tailing (figure 3). Table 4: Regression coefficients and associated probability values for the USP tailing of Gentamicin Term Coefficient p-value Box Behken Model 1.314706 0.0056 Flow rate (ml/min) -0.0125 0.2485 Wavelength (nm) -0.03875 0.0035 Column temp ( C) 0.03375 0.0079 Flow rate x wavelength -0.04 0.0197 Flow rate x column temp 0.015 0.3229 Wavelength x column temp 0.0225 0.1499 Pareto chart Significant factors in Pareto chart are A: Flow rate B: wavelength and C: column temperature. Other seven factors are dummy factors which do not have any physical effect on response and merely added to complete the database of software. 285

Kari Vijayakrishna et al Der Pharma Chemica, 2016, 8 (1):282-288 Figure 1: Pareto chart for Critical Quality Attribute (CQA), USP tailing factor of Gentamicin 1.4 1.4 1.35 1.35 1.3 tailing tailing 1.3 1.25 1.25 1.2 1.2 254.00 37.00 255.00 38.00 0.30 256.00 0.40 B: wavelength 0.30 39.00 0.50 257.00 0.40 0.60 258.00 C: colomn temp 0.70 259.00 260.00 0.80 A: flow rate 0.90 0.50 40.00 0.60 41.00 0.70 42.00 0.80 43.00 (a) Effect of wavelength & flow rate 0.90 A: flow rate (b) Effect of column temperature & flow rate 1.4 1.35 tailing 1.3 1.25 1.2 37.00 38.00 254.00 39.00 255.00 256.00 40.00 C: colomn temp 257.00 41.00 258.00 42.00 259.00 43.00 260.00 B: wavelength (c) Effect of column temperature and wavelength Figure 2: Response surfaces (3D) and contour plots showing the effects of wavelength, flow rate and column temperature on USP tailing factor of Gentamicin 286

Figure 3: Representative chromatogram of Gentamicin with optimized conditions Method validation Method validation was done according to ICH guidelines Q2 [46] and the results were within the specified limit. Thus the developed method is found to be accurate, sensitive, and robust. Validation results are given below in (Table 5, 6, 7) and (Figure 3). Table 5: Validation of method in terms of Accuracy and Precision Level Average area %RSD Intra-day 123462 1.2 Inter-day 123455 1.1 Table 6: Linearity of Gentamicin Standard Concentration (µg/ml) Peak area of Gentamicin 250 14563 500 31529 1000 62315 2000 121196 5000 324015 Regression equation Y = Mx + C Regression coefficient R2 =0.999 Table 7: Validation in terms robustness for Gentamicin Sr. No. Variables Retention time Area of peak +2 5.43 124186sss 0 5.3 125491 Wavelength 1-2 5.39 125375 (nm) average 5.33 125452.3 % RSD 0.974 0.053 2 3 Flow rate (ml/min) Column temperature ( C) +0.2 6.534 108838 0 4.699 109288-0.2 6.534 109211 average 4.66 109262.3 % RSD 1.44 0.0406 +5 5.356 126404 0 5.511 126718-5 5.468 126833 average 5.530 126794.7 % RSD 1.19 0.052 CONCLUSION In this paper a quality by design (QbD) approach was applied to the fast, robust and reliable HPLC method with the assistance of the latest statistical methods. The method development consists of complete understanding of intended purpose. Method was successfully passed through validation and has been used regularly and trouble free. Elements of Quality by Design (QbD) like analytical target profile, instrument qualification, risk assessment, experimental design was studied. Final method conditions are set at injection volume of 20 µl, column temperature at 40 C and wavelength of 257nm and flow rate of 0.6mL/min. Mobile phase was set as 0.01 m diammonium hydrogen phosphate and methanol at 70:30 v/v ratios. Quality by Design (QbD) approach is successfully applied to HPLC method development of Gentamicin content in implants. 287

Acknowledgement SP is thankful to R&D Centre, Matrix Laboratories Ltd; Hyderabad for laboratory facility and Ethiraj for scientific discussion. REFERENCES [1] R.S. Edson, C.L.Terrell, The aminoglycosides: streptomycin etc. Mayo Clin. Proc.74, 1987; 62 (10), 916-920. [2] M.J.Weinstein,G.M. Luedemann, E.M. Oden,G.H. Wagman, Antimicrobial Agents and Chemotherapy, In Proceedings of the Third Interscience Conference on Antimicrobial Agents and Chemotherapy. Washington DC. 1963, 1 13. [3] H.W. Gearald, M.O.Edwin,J.W. Marvin, App. Microbiology,1968; 16(4J), 624-627. [4] The United States Pharmacopoeia and the National Formulary, USP23, NF18,1995, 702. [5] Goodman & Gilman s The Pharmacological Basis of Therapeutics, 9th ed, 2002, 1114. [6] D.Samain, P. Dupin, P.Delrieu, G.Inchaups, J Chromatographia, 24, 1987, 748 752. [7] S. Karolina,B. Agata, F. Zbigniew,S. Katarzyna, J Chromatographia, 2010, 1225 1229. [8] N.C. Megoulas, M.A.Koupparis, J Pharm. Biomed. Anal. 2004, 36, 73 79. [9] C.Shruti, M.Vicky, H. Jos, A. Erwin, Analytical Methods., 2013,5, 2491-2496. [10] E. Adams,W.Roelants, R.De Paepe, E.Roets, J. Hoogmartens, J Pharm. Biomed. Anal., 1998,18, 689 698. [11] R.T. Parfitt, D.E.Games, M.Rossiter, M.S.Rogers, A.Weston, Biomed. Mass Spectrom., 1976, 3, 232 234. [12] T.A.Getek, M.L.Vestal, T.G.Alexander, J. Chromatographia.,1991,554, 191 203. [13] M.Cherlet, S.De Baere, P.De Backer, J. Mass Spectrom.,2000,35,1342 1350. [14] D.Loffler,T.A. Ternes, J. Chromatographia A., 2003,1000,583 588. [15] M.C.Lecaroz, m.a.campanero,c.gamazo, M.Blanco-Prieto, J. Antimicrob. Chemother., 2006, 58, 557 563. [16] S.K.Maitra,T.Y.Yoshikawa, J.L.Hansen,I.Nilsson-Ehle, W.J.Palin,M.C.Schotz, L.B.Guze, J. Clinical Chemistry., 1977, 23, 2275 2278. [17] G.W.Peng, M. A.Gadalla, A.Peng, V.Smith, W.L.Chiou, Clinical Chemistry,1977, 23,1838 1844. [18] W.Lesniak,J.Mc Laren, W.R.Harris,V.L.Pecoraro,J. Schacht,Carbohydrate research., 2003,2853 2862. [19] A.Olajire, Adegoke, African J of Pure and Appl Chem., 2012,129-140. [20] L.O.White, A.Lovering, D.S. Reeves, Ther.Drug Monit., 1983,5,123 126. [21] I.Nina,L. Eran, S.Stefan, Antimicrobial Agents Chemotherapy.,2000,44,1443 1447. [22] B. A. Elisabete de Almeida, R.L.Felipe,A.P.Terezinha de Jesus, Brazilian J of Phar.,2011, 262-268. [23] S.Karolina,B.Agata, F.Zbigniew, S.Katarzyna, Chrom1qa., 2010,1225 1229. [24] A.O.Mahmoud,M.N.Dalia, A.H.Mohamed, A.A. Alshymaa, J of App Pharm., 2013, 151-161. [25] M.L.Marie-Paule, G.Youri,M.T.Paul,Antimicrobial Agents Chemother., 1999,727 737. [26] E.Kaale, S. Leonard, S. Van, E.Roets, J.Hoogmartens, J Chrom A., 2000, 895, 67 79. [27] ICH Q8 Pharmaceutical Development, ICH Q9 Quality Risk Management, ICH Q10 Pharmaceutical Quality System. [28] P.F.Gavin, B.A.Olsen, J. Pharm Biomed Anal., 2008,46,431 441. [29] W. Li, H.T. Rasmussen, J. Chromatographis A., 2003,1016,165 180. [30] Y.H.Lin, Y.H.Yang,S.M. Wu, J. Pharm Biomed Anal., 2007,44,279 282. [31] S. Karmarkar,R.Garber,Y.Genchanok, S.George, X.Yang, R.Hammond, J. Chro Sci., 2011, 49, 439-446. [32] S. Fekete,J. Fekete,I. Molnar, K.Ganzler, J. Chromatographia A., 2009, 1216,7816 7823. [33] B.J. Stojanovicn, T. Rakic,B. Slavkovic, N.Kostic, A. Vemic, A. Malenovic, J. of Pharm Analysis., 2013, 3, 45-52. [34] A.H. Schmidt, I. Molnar, J. Pharm Biomed Anal., 2013, 5, 78-79. [35] K. Garg,V. Reddy, S. Sait, T. Krishnamurthy, J. Vali, M. Reddy, J. Chromatographia, 2013, 76,1697-1706. [36] E. Rozet, P. Lebrun, B. Debrus, B. Boulanger,P. Hubert, Trends in Anal Chem., 2013, 42,157-167. [37] P. Ramalingam, B.Kalva, R.Yiragam, R. Padmanabha, Int J of Anal Chem., 2015, Article ID 868727. [38] S. Karmarkar,R. Garber,Y. Genchanok, S. George, X. Yang, R. Hammond, J. Chrom Sci., 2011, 49, 439. [39] F. Vogt, A.Kord, J. Pharm Sci., 2011, 100, 797-812. [40] B. Debrus, D. Guillarme, S. Rudaz, J. Pharm Biomed Anal. 2013, 84, 215-223. [41] B. Dejaegher, Y. Vander Heyden, J. of Pharm Biomed Analysis., 2011, 56,141 158. [42] D. Awotwe-Otoo,C. Agarabi, P.J.Faustino,M.J. Habib,S.Leec,M.A. Khana,R.B. Shaha, J. Pharm Biomed Anal., 2012, 62, 61-67. [43] L. George, HPLC Methods for recently approved pharmaceuticals, Wiley & Sons : New York, 2005. [44] A. Pedro, J. of Chrommatographia B. 2009, 877, 2224 2234 [45] G. Mark, Anal. Chemistry,1996, 68 (9), 305 309. [46] ICH Q2 : Vaidation of Analytical Procedures, Pharmaceutical Quality System. GMP Publ. 2005. 288