The EA Laboratory Committee point of view of IQC activities. Ioannis Sitaras, Hellenic Accreditation System S.A-ESYD, Greece

Similar documents
QA/QC to underpin the measurement cycle

The role of accreditation bodies and EQA organisers in the. specifications

ISO and SANAS guidelines for use of reference materials and PT scheme participation. T & M Conference

Guidelines for the assessment of the appropriateness of small interlaboratory comparisons within the process of laboratory accreditation

From purpose based interpretation to appropriate application of Calibration and Interlaboratory comparison results

Measurement uncertainty: Requirements set in the accreditation standards

List of Conclusions and Resolutions agreed at the 33 rd Meeting of the EA Advisory Board held on 22 October 2014

BD TN 4.0: GAC Technical Note 4 Proficiency Testing Policy. 1. Purpose / Scope. 2. Terms / Definitions. 3.

ILAC P10 TRACEABILITY

Inter American Accreditation Cooperation IAAC APPLICATION FOR THE ASSESSMENT AND ACCREDITATION OF PROFICIENCY TESTING PROVIDERS

The new ISO/IEC 17025:2017

A2LA. G123 - Guidance for Cannabis Laboratories Preparing for Accreditation

Delivering a safer world

GENERAL GUIDELINES FOR THE ACCREDITATION OF FOOD AND ENVIRONMENTAL MICROBIOLOGICAL LABORATORIES

Checklist for assessment of Metrological Traceability and Measurement Uncertainty of calibration laboratories NC NA

Preparation Approval Authorisation Application date. Directive Council The President

P112 Flexible Scope Policy

APLAC GUIDELINES FOR FOOD TESTING LABORATORIES

Proficiency Testing. Bryanne Shaw Biology Section Manager

IL AC-G22:2004. Use of Proficiency Testing as a Tool for Accreditation in Testing

Handbook ISO/IEC 17025:2017

RAJESH NAIR DIRECTOR CALF-NDDB, ANAND, GUJARAT

Rules for accreditation of providers of proficiency testing/interlaboratory

Laboratory Quality Assurance Manager & Laboratory Assessor RULES & HANDBOOK

DESIGN AND OPERATION OF AN INTERLABORATORY COMPARISON SCHEME

FQS Accreditation for forensic testing agencies NEMC ANSI-ASQ National Accreditation Board

EA MULTILATERAL AGREEMENT Facilitating cross border trade with reliable goods and services

NATA Policy on Calibration and Measurement Traceability

Wilmington Police Department Crime Laboratory Quality Management System Procedure Measurement Traceability and Uncertainty

A comparison of the complimentary and different issues in ISO/IEC and OECD GLP

Part II: Requirements for the Management of Schemes

Inter American Accreditation Cooperation

Policy on the Traceability of Measurement Results

RULES FOR THE PARTICIPATION IN INTER- LABORATORY COMPARISONS AND PROFICIENCY TESTING SCHEMES

TECHNICAL REQUIREMENTS (CLAUSE 5)

Guidelines for the monitoring and reporting of the operation of quality systems by RMOs

Guidance on Proficiency Testing / Inter-laboratory Comparisons

Laboratory Challenges with TNI Implementation and Laboratory Audits

ISO 15189:2012 and Susceptibility Testing BSAC User Day 22 June 2016

Workshop Schedule. To visit the registration website, please go to:

Measuring Instruments Directive 2014/32/EU Assessment of Notified Bodies in Charge of Type Examination Presumption of Conformity based on EN 17065

KENYA ACCREDITATION SERVICE

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

Title Procedure for setting up the accreditation of new conformity assessment schemes

Mentoring Session: Topics in the New TNI Laboratory Accreditation Standards

Laboratory Management & Quality Assurance

ILAC Mutual Recognition Arrangement: Policy and Management ILAC-P4:06/2017

ISO/IEC Conformity assessment General requirements for proficiency testing

How accurate measurements in the energy emission trading?

QMS Quick Learning Activity. Proficiency Testing ISO/IEC 17025:2005.

Global Context of Food Safety

STATIONARY SOURCE AUDIT SAMPLE PROGRAM [VOLUME 1, MODULE 2] GENERAL REQUIREMENTS FOR AN ACCREDITOR OF STATIONARY SOURCE AUDIT SAMPLE PROVIDERS

PROFICIENCY TESTS PROTOCOL. Document valide au 21/02/2018. Editor: Marie-Phillipe SEILLER

APLAC GUIDANCE ON REFERENCE MATERIAL USE AND PRODUCTION

American Association for Laboratory Accreditation

Overview of Good Food Laboratory Practices

CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES

A02 Assessment Rating Guide Revision 2.9 August 21, 2016

DECISION TO ACCREDIT

The Role of Proficiency Testing in Laboratory Capacity Building in Chile

Meeting the ISO/IEC Requirements for Traceability and Measurement Uncertainty. APLAC Approaches. Dr Bernard King NARL, Australia

Introducing the Concept of Uncertainty of Measurement in Testing in Association with the Application of the Standard ISO/IEC 17025

Implementing the New TNI Standard. April 7, 2011

Guidance on the Application. of ISO / IEC Accreditation International Association for Certifying Bodies

ISO 13528:2015 Statistical methods for use in proficiency testing by interlaboratory comparison

PALCAN Guidance for the Validation of Test Methods

General Use of Proficiency Testing in Accreditation Scope

ILAC-P10:2002. ILAC Policy on Traceability of Measurement Results

General requirements for the competence of testing and calibration laboratories. In this presentation:

EA Guidance on Accreditation of Pesticide Residues Analysis in Food and Feed

American Association for Laboratory Accreditation

MODULE 2A GENERAL MANAGEMENT SYSTEM REQUIREMENTS

Establishment of an Accredited Reference Measurement Laboratory

The 2016 TNI Laboratory Accreditation Standard. November 15, 2017

The importance of valid analytical measurements

A24 CALA Checklist for Microbiology Revision 4.1 February 16, 2018

TRAINING COURSES CALENDAR 2019

Institute for Health and Consumer Protection

SEMIS COURSE ON SEED QUALITY ASSURANCE, MANAGEMENT AND CONTROL PROCESSES. PRESENTED BY Munyao W. M.

Quality System Guidance

OIML B 18 Edition 2018 (E)

CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES

ACCREDITATION A TOOL TO SUPPORT REGULATORS

ACCREDITATION A TOOL TO SUPPORT REGULATORS

ACCREDITATION A TOOL TO SUPPORT REGULATORS

A2LA. R231 Specific Requirements: Threat Agent Testing Laboratory Accreditation Program. December 6, 2017

PALCAN Policy on Use of Proficiency Testing as a Tool for Accreditation in Testing (ILAC-G22:2004)

Quality System Guidance

ILAC-P10:01/2013 -Calibration-

General Accreditation Criteria Equipment assurance, in-house calibration and equipment verification

Protocol for intercomparison exercise, final version December 2008 AQUILA N 37

Will Accrediting Authorities allow PT Providers to reissue a result report if the lab identifies a reporting problem? Sponsor: Bill Hall Resolution:

A12 CALA Policy on Reference Methods Revision 1.4 July 6, 2018

TECHNICAL AND PRODUCTION REQUIREMENTS of ISO Guide 34:2009

TNI Policy Committee Meeting Summary Friday, June 1, 2018

Application of ISO/IEC 17025

Update on the IEA 4E SSL Annex. David Boughey. Australian Government Department of Resources, Energy and Tourism

Procedure for Equipment Calibration and Maintenance

Revisione della norma ISO 4259 Andrea Gallonzelli

Terms and conditions for laboratories appointed to undertake the testing of compost under the Compost Certification Scheme aligned to PAS 100 and the

Transcription:

EURACHEM WORKSHOP Key Challenges in Internal Quality Control, Berlin 10-11 October 2012 The EA Laboratory Committee point of view of IQC activities Ioannis Sitaras, Hellenic Accreditation System S.A-ESYD, Greece Contents Short Presentation of EA/LC Introduction ISO 17025:2005 and IQC Internal Quality Control Procedures assessing components Consistency of IQC assessment Technical Guidance Issues defined for the assessment of IQC 1

Short Presentation of EA/LC EA Laboratory Committee EA/LC is the forum for discussion of all questions related to the assessment and accreditation of laboratories. Some of its responsibilities: to harmonize the implementation of the standard ISO/IEC 17011 with a view to the assessment and accreditation of laboratories against ISO/IEC 17025, ISO 15189, ISO/IEC 17043 and other relevant standards and to elaborate guidance documents where necessary to cooperate with relevant working parties of related European organizations, especially as far as the implementation of the standards defining technical and organizational competence of laboratories is concerned, in particular the recognised stakeholders and, if appropriate, to approve guidance documents drafted by these organizations as EA advisory documents 2

Membership of EA/LC one representative of each EA member and associate member the conveners of the Working Groups and Joint Working Groups and Technical Networks representatives from regional organizations as EUROLAB, EURACHEM, EURAMET and other Stakeholder organizations, invited by the Chair or Vice Chairperson of EA/LC or by the EA Executive Committee; representatives from other organizations invited by the Chairperson representatives of the recognised stakeholders Working Groups and Technical Networks 3 Working Groups have been established by EA/LC to assist specific areas (ILCs in Calibration, ILCs in testing, Health Care) Technical networks (TN) are established by the LC to stimulate discussion and harmonisation in selected technical fields. The TNs operate by suitable electronic means led by a convenor and offer the EA ABs an informal platform for discussion and exchange of experience and of technical expertise and assessors. 5 TNs are currently active (Calibration, Electrical-Mechanical, Environment, Food, Forensic) 3

Introduction IQC activities when assessing a laboratory (1/2) As for the assesment the Internal Quality Control procedure consists of: A major part in the process of building confidence to the competence A core requirement of the accreditation standard in order to ensure that valid results are produced 4

IQC activities when assessing a laboratory (2/2) Internal Quality Control is assessed as a part of the Quality Assurance Procedures along with participation in PT schemes Quality Assurance Procedures are assessed as a part of the overall quality system A laboratory that performs an effective and sufficient IQC scheme, having documentation that deviations have been or will be treated accordingly, provides a reliable indication that itself can control and correct problems, thus builds confidence for its competence ISO 17025:2005 and IQC 5

ISO 17025:2005 and internal quality control Direct Reference The standard contains 59 clauses, of which 2 directly address internal quality control requirements Section 5.9 Assuring the quality of test and calibration results 5.9.1 The laboratory shall have quality control procedures for monitoring the validity of tests and calibrations undertaken. The results shall be recorded in such a way that trends are detectable and, where practicable statistical techniques shall be applied to the reviewing the results.....the monitoring shall be planned and reviewed and may include but its not limited to, the following Regular use of CRMs and/or IQC Participations in ILCs or PT programs Replicate tests or calibrations using the same or different methods 5.9.2 Quality control data shall be analyzed and where they are found to be outside pre-defined criteria, planned action shall be taken to correct the problem and to prevent incorrect results from being reported. ISO 17025:2005 and internal quality control Indirect Reference (1/2) Identification of non conforming work (4.9.1 Note) Quality control is recognized as a potential area to identify problems Continuous improvement (par.4.10) The laboratory shall continually improve the effectiveness of the quality system. This would include reviewing and evaluating developments in AQC practices Also in par. 4.10 use of quality objectives for the monitoring of the effectiveness of the quality system: A laboratory would make use of the IQC data in the form of quality objectives in order to monitor the performance of quality assurance procedures 6

ISO 17025:2005 and internal quality control Indirect Reference (2/2) Management Reviews (par.4.15.1) Issues to be examined during a management review along with the results of interlaboratory comparisons and proficiency tests : other relevant factors such as quality control activities, resources and staff training One can expect that the results of internal control procedures and if relevant, corrective actions raised from deviations are taken into consideration in order to review the performance of the laboratory Internal Quality Control Procedures assessing components 7

What a lab has to do? In order to establish an effective IQC system, a laboratory would follow a path more or less like this: 1. Define quality goals as needed 2. Develop policies to achieve the quality goals and create a plan for the IQC 3. Establish processes and procedures to implement the IQC plan 4. Monitor and review the relevance and effectiveness of the IQC system What an assessment team has to do? An assessment team is assessing the IQC among other sections of the quality system. A Technical Assessor is expected to be a competent person of a relevant experience and competence to the assessed scope. Normally he/she will follow the same path to have a view into the level of conformity of the laboratory to the ISO/IEC 17025 requirements 8

1. Definition of Quality Goals The laboratory established overall quality goals regarding the method, the application of the method, the risk for invalid results. For this, method performance criteria defined in standard methods and/or regulatory requirements, or set by customer or required by the accreditation requirements, have to be taken into consideration Risk factors for deviations and loss of control depending to the method and the application, the availability of resources have also to be considered Did the laboratory take into consideration all the parameters to determine the risk level and to set the quality goals? 2. Develop policies-create IQC plan Components Specific QC measures Consider test limitations Availability of control materials Frequency Design (boundaries, scope of application) What else has to be assessed Technical expertise to perform the test Evaluating and selecting QC materials Selection and use of QC charts Selection of matrices/analytes/levels Selection of control/warning limits (Method? Legislation? Other requirements) 9

3. Implementation of the IQC plan Components Detailed procedures and predefined actions Description into the method SOP Use and store of technical records Training Responsibilities for the evaluation of the IQC To further examine Knowledge and understanding of specific QC statistics Interpretation of QC patterns and reaction to deviations Reaction to out of control situations Log and maintain QC records and corrective actions Consideration of IQC results in relation to external quality control results 4. Monitor and review the relevance and effectiveness of the IQC system Components IQC should reflect current laboratory conditions and requirements. Any change should be adressed IQC data are valuable to other sectors (method validation, quality objectives etc). Items to be addressed IQC in relation to the workload/changes in the laboratory conditions, requirements Feedback of IQC data to other sections of the quality system 10

Consistency of IQC assessment The assessment process of IQC and its consistency (1/2) ISO/IEC 17025 :2005 only defines outcomes in form of requirements It does not specify processes by which these outcomes can be achieved For IQC, the standard however, suggest possible options The laboratory, in each case as for the selection and participation in PTs, is fully responsible for the establishment of a proper IQC system and the choice of the processes to provide it Accreditation Bodies have to assess these processes if they satisfy the requirements of the standard 11

The assessment process of IQC and its consistency (2/2) ABs seek assessment consistency through Assessment training Use of technical guidance Case studies, assessors meetings, reviews from assessment reports, feedback from the labs The IQC consists of the application of general criteria to a specific case (technical field, laboratory, application) Every assessment can be a different case It is difficult to define general requirement for each case and it is difficult to calibrate technical assessors for the assessment of IQC Technical Guidance with reference to IQC 12

Examples of EA documents The following EA documents and documents adopted by EA as technical guidance for the application of ΙSO/IEC 17025 contain, among other things, guidance for the internal quality control requirements EA-4/10 G (rev.02) Guidance Accreditation for Laboratories Performing Microbiological Testing, under revision CEC TA ISO/IEC 17025 interpretation document for CEC test methods EA-4/09 G (rev.01) Guidance Accreditation for Sensory Testing Laboratories, under revision EWDTS TA Technical / Advisory European Laboratory Guidelines for Legally Defensible Workplace Drug Testing and Technical Advisory Drug and Alcohol Testing in Hair, Collection and Analysis Under development GMO quantitative testing: under development by ENGL with cooperation with EA LC Food Testing Technical Network Examples of other documents Other documents where direct reference to internal quality control is given: Antidoping testing: WADA ISL 7.0 Pesticide residues testing: Method Validation and Quality Control.Procedures for Pesticide Residues analysis in Food and Feed9 Document N SANCO/12495/2011 It also common, National Accreditation Bodies to issue guidance documents for example: water testing, metals testing, residues testing, guidance for traceability, medical laboratories accreditation, where detailed guidance and requirements for the establishment of internal quality control are referred. 13

Issues defined for the assessment of IQC Indirect use of IQC data in the quality system Evaluation of technical competence of the personnel (par.5.1.1) Evaluation of the effectiveness of a training activity (par. 5.2.2) Update of validation, uncertainty data 14

Other issues (1/2) Frequency of IQC Use of control limits as regulatory requirements (for example SANCO document requirements) Use of IQC as a tool (along with participation in PTs) in order to keep an inactive method (no samples) in the accreditation scope Other issues (2/2) Review of cases of corrective actions related to deviations/problems identified through IQC The flexible scope and the IQC Laboratories develop flexibility in their accreditation also need to establish an IQC system capable to follow the extension of the accredited activities within the flexible scope boundaries 15

Survey among EA-ABs Conducted in the framework of EA/LC, last meeting, Oslo 9 common finding in the assessment of IQC Relative Rating regarding occurrence and significance 8 ABs have already responded (AAB,ACCREDIA,COFRAC, DAkkS, DANAK, ESYD, FINAS, NA) Rate on Significance of the findings Findings related to the ISO/IEC 17025:2005 requirements for internal quality control as described in par. 5.9 or relative ones The IQC scheme concluded to the identification of a deviation, but the laboratory didn t start a corrective action Internal Quality Control samples/materials are not proper for the method 18 SCORE on the significa nce 22 The established scheme for internal quality control does not fully cover the scope of application of the method. (for example matrices/analytes/concentration levels) The criteria set for the IQC are not conformed to those defined in the method/or in regulatory requirements/or in other requirements, for example accreditation guidance 17 16 The laboratory has not predefined actions in case of deviations from internal quality control 16 The IQC patterns have not been interpreted correctly (for example trends in QC charts have not been identified) 13 The frequency of internal quality control is not assuring its effectiveness 13 QC data have not been reviewed in order to update the validation/verification data of the method. 13 QC charts have not been constructed the right way 10 16

Rate on the Occurrence of the findings Findings related to the ISO/IEC 17025:2005 requirements for internal quality control as described in par. 5.9 or relative ones The IQC scheme concluded to the identification of a deviation, but the laboratory didn t start a corrective action SCORE on the occurrenc e 42 QC data have not been reviewed in order to update the validation/verification data of the method. 39 The IQC patterns have not been interpreted correctly (for example trends in QC charts have not been identified) 35 The laboratory has not predefined actions in case of deviations from internal quality control 32 The criteria set for the IQC are not conformed to those defined in the method/or in regulatory requirements/or in other requirements, for example accreditation guidance The established scheme for internal quality control does not fully cover the scope of application of the method. (for example matrices/analytes/concentration levels) 32 32 Internal Quality Control samples/materials are not proper for the method 29 The frequency of internal quality control is not assuring its effectiveness 28 QC charts have not been constructed the right way 26 Other findings proposed by the ABs assessment by the laboratory on the significance of out-ofcontrol-situation is missing estimated values showing out-of-control are not registered in the control chart (test is repeated until value is well within control) No certified reference materials are used for IQC, even if available 17

Total Score of the findings Findings related to the ISO/IEC 17025:2005 requirements for internal quality control as described in par. 5.9 or relative ones The IQC scheme concluded to the identification of a deviation, but the laboratory didn t start a 117 corrective action Internal Quality Control samples/materials are not proper for the method 65 The laboratory has not predefined actions in case of deviations from internal quality control 63 The criteria set for the IQC are not conformed to those defined in the method/or in regulatory 61 requirements/or in other requirements, for example accreditation guidance The established scheme for internal quality control does not fully cover the scope of application of 59 the method. (for example matrices/analytes/concentration levels) The IQC patterns have not been interpreted correctly (for example trends in QC charts have not 58 been identified) QC data have not been reviewed in order to update the validation/verification data of the method. 57 The frequency of internal quality control is not assuring its effectiveness 46 QC charts have not been constructed the right way 40 SCORE of COMBINED EFFECT : occurrence x significance Conclusions Most common findings The IQC scheme concluded to the identification of a deviation, but the laboratory didn t start a corrective action QC data have not been reviewed in order to update the validation/verification data of the method. The IQC patterns have not been interpreted correctly (for example trends in QC charts have not been identified) Most significant and common findings The IQC scheme concluded to the identification of a deviation, but the laboratory didn t start a corrective action Internal Quality Control samples/materials are not proper for the method The laboratory has not predefined actions in case of deviations from internal quality control One could find satisfactory the consistency among the different ABs regarding the occurrence and significance of the findings 18