Errata Sheet. LEED for Schools Reference Guide First Edition for the document titled:

Similar documents
Errata Sheet. LEED for Schools Reference Guide First Edition for the document titled:

LEED for New Construction Version 2.2 Reference Guide Second Edition, September 2006

CONTENTS. 71 Section 01352, #7 (Life Cycle Cost and Life Cycle Assessment) 2/1/12 Modified entire section 72 Section 01352, #8 (Sustainability

and LEED Energy and Atmosphere Credits Jean Ascoli, LEED AP BD+C Architect, Energy Specialist

LEED Application Guide for Multiple Buildings and On Campus Building Projects

ATTACHMENT N LEED PROJECT PROCEDURES

TECHNICAL BULLETIN. MR 7.0 Certified Wood Encourage environmentally responsible forest management.

LEED Application Guide for Multiple Buildings and On-Campus Building Projects

EnviroLube LEED Point Contribution

SECTION SUSTAINABILITY CERTIFICATION REQUIREMENTS LEED NC V3

Recommended Amendments to the

Lori A. Brown, LEED AP BD+C, LEED AP ND, LEED AP O+M -- LEED Green Associate Exam -- Power Jam Study! -- lorisweb.com 1

Required Treatment of District Thermal Energy in LEED-NC version 2.2 and LEED for Schools

Allowance Table for: General:

Exemplary Performance

A. The project is intended to achieve LEED Certification at the Silver Level per the U.S. Green Building Council LEED for Schools 2007 rating system.

LEED BD+C: NC, CS, S, R, DC, WDC, HOS, HC

Update on LEED v3. All projects registered after June 26, 2009 must be under the guidelines of LEEDv3. A LEEDv3 summary of changes:

LEED v4 Credit Guidance for Andersen Products LEED for Building Design and Construction: Homes and Multifamily Midrise

LEED Analysis of the Knight Management Center. Energy & Atmosphere. Materials & Resources

CAMP BLANDING JOINT TRAINING CENTER CONSTRUCTION AND FACILITY MANAGEMENT OFFICE ARCHITECT S PROJECT # CFMO PROJECT #

Alpen Windows - LEED Impact Analysis

Prerequisite. prerequisite.

EA PREREQUISITE 2: MINIMUM ENERGY PERFORMANCE

University of Minnesota Duluth Civil Engineering Building

LEED Building Design & Construction Contribution NC v4.0 (April, 2017)

Title: In-House Green Building Certification Supporting Documentation Issued by: Sustainability Department (Green Building Department)

L E E D S C O R E C A R D ( B U I L D I N G D E S I G N & C O N S T R U C T I O N )

GREEN BUILDING GUIDELINES

LEED LEED. Leadership in Energy and Environmental Design. A voluntary, consensus-based. high-performance, sustainable buildings and neighborhoods

Session no. B LEAD WITH LEED

Petersen Aluminum Leadership in Energy and Environmental Design (LEED ) Guidelines

DIRECTIVE 1B-7 Issue date: October Energy, Sustainability, LEED and Executive Orders

Note year for Reference as Specified in the LEED V Manual.

Crawford House Office Building

ELG4126 Sustainable Development for Electrical Engineers

Product LEED Guide Vexcon Chemicals, Inc. 1

CENDREX THE ACCESS DOORS, ROOF HATCH, FLOOR HATCH AND CABINETS

What s New in LEED O+M v4: Get Ready for the Future! A Presentation by The Sustainability Experts Leonardo Academy At NFMT Las Vegas

USGBC LEED Rating Systems and Energy Requirements

A PRACTICAL GUIDE TO SAN FRANCISCO'S GREEN BUILDING ORDINANCE

Navigating Vermont s New Core Performance Guide. Session Overview 2/18/2008

LEED And Your Indoor Environment

Thermiser Insulated Rolling Doors Comprehensive Guide to Earning LEED v4 Credits

Decoustics and LEED Leadership in Energy and Environmental Design

Impact Barrier QT LEED Sheet

Introduction to LEED v4 Lyle Scott May 22, 2014

SECTION SUSTAINABLE DESIGN REQUIREMENTS LEED FOR NEW CONSTRUCTION AND MAJOR RENOVATIONS

McElroy Metal Guideline for Leadership in Energy and Environmental Design (LEED) version 4

Be free to create: Polycrete, a durable choice

OPTION 1: PERFORMANCE RATING METHOD

Using ASHRAE s ECB Method for determining the LEED TM Energy & Atmosphere Credits

PRELCO INC. PRINTED PREL-DESIGN GLASS

Designing Beyond Code For Energy Efficiency

MATERIALS AND RESOURCES

LEED 2009 FOR EXISTING BUILDINGS OPERATIONS AND MAINTENANCE ACP DOCUMENTATION GUIDANCE FOR PROJECTS OUTSIDE THE U.S.

LEED CERTIFICATION PROJECT REVIEW REPORT

Example LEED-NC v2.1 Energy & Atmosphere Credit 1 Submittal

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P edition) Energy Standard for Buildings Except Low-Rise Residential Buildings.

ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P edition) Energy Standard for Buildings Except Low-Rise Residential Buildings.

Dayton Chapter February 9, Bob Thomson, P.E., LEED-AP, CDT

CREDIT COMPLIANCE (Please complete the color coded criteria(s) based on the option path selected)

Multi-Institutional Academic Health Science & Research Center Evansville, IN

STC MANUFACTURER STEEL DOOR WITH PLYWOOD 3/4

ASSA ABLOY Door Security Solutions Contribution Toward LEED v4 Certification

Prerequisites must be achieved. Non-compliant prerequisites must be resolved before a certification can be awarded.

HPBS [ HIGH PERFORMANCE BUILDING STANDARD]

Effective Date: April 25, 2016 Revised: November 7, 2017

ALBUQUERQUE PUBLIC SCHOOLS Facility Design & Construction / Maintenance & Operations

Indoor Air Quality (IAQ) Requirements

Appendix C APPLICATION #: ADDRESS: CITY OF SANTA CRUZ GREEN BUILDING PROGRAM GREEN POINTS CHECK LIST FOR NON-RESIDENTIAL BUILDINGS

LEED v4 Technical Bulletin Building Design + Construction

Treatment of District or Campus Thermal Energy in LEED for Existing Buildings: Operations and Maintenance

PRELCO INC. INSULATING GLASS THERMALITE

ICYNENE AND LEED NC LEED 2009 FOR NEW CONSTRUCTION AND MAJOR RENOVATIONS

LEED Green Building Leadership. LEED Data. Green Building Leadership

COMMISSIONING, OPERATION AND MAINTENANCE

LEED v4 Technical Bulletin Building Design + Construction

BETA OPTION 1: PERFORMANCE RATING METHOD. Section General Information

COUNTY OF RIVERSIDE, CALIFORNIA BOARD OF SUPERVISORS POLICY. Policy Subject: Number Page. SUSTAINABLE BUILDING POLICY H-29 1 of 5

**Section C and R ; change to read as follows:

PROPOSED SAN FRANCISCO GREEN BUILDING CODE AMENDMENTS 2016 Edition

St. Monica Food Pantry Construction Waste Management and Disposal SBA-13105

LEED v4 LEED BD+C Credit-by-Credit Review

Opportunities for BaySystems Spray Foam & Specialty Coatings to Contribute to USGBC s LEED Performance

Nordic Structures Revised May 9, 2018

Nordic Structures Revised February 28, 2018

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLEXIBLE FLASHINGS REPORT HOLDER: HUBER ENGINEERED WOODS, LLC

Roseburg RIGIDLAM LVL Roseburg Forest Products Company Revised May 31, 2018

IECC Residential Significant Changes Summary. Tier I

Learning to LEED: Day 2 Materials & Resources Quiz

POTENTIAL CONTRIBUTION LEED U.S. & INTERNATIONAL-NC & CS LEED TECHNICAL DATA SHEET EXPERTS IN SYNTHETIC PALM SOLUTIONS ENVIRONMENTALLY RESPONSIBLE

Balco, Inc. Stair Nosings

POTENTIAL CONTRIBUTION LEED U.S. & INTERNATIONAL-NC & CS LEED TECHNICAL DATA SHEET EXPERTS IN SYNTHETIC PALM SOLUTIONS ENVIRONMENTALLY RESPONSIBLE

LEED version 4 Leadership in Energy and Environmental Design

UNIVERSITY OF ROCHESTER DIVISION 01 SPECIFICATIONS November 4, 2013 SECTION SUSTAINABLE DESIGN REQUIREMENTS - LEED FOR NEW

CENDREX AHD - GENERAL PURPOSE ACCESS DOOR FOR ALL SURFACE TYPES

SUSTAINABILITY REPORT

CE Option 1 and 2 - Provide the pre-development site run -off rate (cfs) CE Option 1 and 2 - Provide the pre-development site run -off quantity (cf)

Transcription:

Errata Sheet for the document titled: LEED for Schools Reference Guide First Edition 2007 Notes: Updates to this document are posted on the LEED for Schools Rating System page and the Reference Guide electronic access Web page (via www.usgbc.org/myusgbc). Errata posted 6/13/2008 EQc3.1 341 Under the heading Requirements, in the first bullet point, the referenced standard has been updated to the SMACNA IAQ Guidelines for Occupied Buildings under Construction, Second Edition-November 2007, chapter 3 Errata posted 4/7/2008 MRc7 298 & Under Summary of Referenced Standard (p288) and Resources (p291), change the Forest Stewardship Council, United States phone number to (703) 438-6401 301 MRc7 298 Revise the Chain of Custody (COC) Certification definition to: Chain-of-Custody (COC) Certification enables tracking of wood all the way through the value chain into final products. It is awarded to companies that produce, sell, promote, or trade forest products after audits verify proper accounting of material flows and proper use of the FSC name and logo. MRc7 299 Replace the text under Chain-of-Custody Requirements with the text below: Chain-of-Custody Requirements Each wood products vendor that invoices FSC-certified wood products to project contractors and subcontractors must be COC-certified by an FSC-accredited certifier. Contractors and subcontractors are not required to have COC certification. MRc7 299 Replace the text under Calculations with the text below: MRc7 299-300 List all new (i.e. not reclaimed, salvaged, or recycled, etc.) wood products used on the project and identify which products are FSC certified. Using Equation 1, tally both the non-fsc-certified wood and the FSC certified wood. Wood products that are identified as FSC Pure or FSC Mixed Credit shall be valued at 100% the product cost. Wood products identified as FSC Mixed [NN]% should be valued at the indicated percentage of their cost, e.g., a product identified as FSC Mixed 75% should be valued at 75% of the cost. FSC Recycled and FSC Recycled Credit products do not contribute to this credit. Replace the title Assemblies with Products that Combine Wood and Other Materials and under that heading replace the existing text with the following: Errata Sheet for LEED for Schools Reference Guide 1 of 8

In the case of manufactured products such as windows and some furniture systems that combine wood and non-wood materials, only the wood portion can be applied toward the credit. To determine the value of the wood portion, calculate the amount of wood as a percent of the total weight, volume, or cost of the product and multiply this by the total value of the product as invoiced to project contractors, subcontractors, or buying agents. If the wood portion of the assembly product is identified as FSC Pure or FSC Mixed Credit, then 100% of the value of the wood portion shall count toward achievement of the credit. If the product is identified as FSC Mixed [NN]%, then the wood portion should be valued at the indicated percentage, e.g., for a product identified as FSC Mixed 75%, the wood portion should be valued at 75% of the cost. The calculations for certified wood shall include only new wood products. The value of any recycled wood fiber content of a product that qualifies as contributing to MR Credit 4, Recycled Content Materials, shall be excluded MRc7 300 Replace the text under Submittal Documentation with the text below: This credit is submitted as part of the Construction Submittal. The following data and calculation information is required in order to complete the v2.2 Submittal Templates: For all permanently-installed wood products, both FSC-certified and not, vendor invoices must be compiled, and wood price values entered into the submittal template. A Vendor is defined as the company that sells wood products to building project contractors or subcontractors. Each vendor invoice must conform to the following requirements: 1. Each wood product must be identified on a line-item basis; 2. FSC products must be identified as such on a line-item basis and must be identified as FSC Pure, FSC Mixed Credit, or FSC Mixed [NN]% ; 3. The $ value of each line item must be shown; 4. The vendor s chain-of-custody (COC) number must be shown on any invoice that includes FSC products. Exceptions in some rare instances, it may not be practical for a vendor to invoice wood products on a line-item basis because the invoice would be dozens of pages long. In such cases, the invoice should indicate the aggregate value of wood products sold by the vendor. If the wood products are FSC certified: 1. The vendor s COC number must be shown on the invoice; 2. The invoice must be supplemented by a letter from the vendor stating that the products invoiced are FSC certified. 3. The invoice or the letter must state whether the products are FSC Pure, FSC Mixed Credit, or FSC Mixed [NN]%. An optional narrative can be submitted describing any special circumstances or Errata Sheet for LEED for Schools Reference Guide 2 of 8

considerations regarding the project's credit approach. MRc7 301 Under Definitions, revise the Chain of Custody (COC) definition so it reads as follows: Chain-of-Custody (COC) is the path taken by raw materials, processed materials, and products from the forest to the consumer, including all successive stages of processing, transformation, manufacturing and distribution. The COC certificate number is listed on vendor invoices for products to document that an entity has followed FSC guidelines for product accounting. MRc7 301 Under Definitions, strike the last sentence of the definition of Vendor, so it reads as follows: Vendor is defined as the company that supplies wood products to the building projects contractors or subcontractors. Errata posted March 7, 2008 EAc1 194 Beneath option 2, please insert the text below. OPTION 3 ADVANCED ENERGY DESIGN GUIDE FOR K-12 SCHOOL BUILDINGS (4 Points) Comply with the prescriptive measures of the ASHRAE Advanced Energy Design Guide for K-12 School Buildings. The following restrictions apply: K-12 school building must be under 100,000 square feet. The school building uses one of the HVAC systems specified in Chapter 3 climate zone tables and follow recommendations contained in Chapter 5 (HV1-32), as appropriate for the climate zone in which the building is located. The scope of the Advanced Energy Design Guide applies to K-12 buildings with administrative and office areas, classrooms, hallways, restrooms, gymnasiums, assembly spaces, food preparation spaces, and dedicated spaces such as media centers and science labs. Schools that include any of the following specialty spaces cannot use the Advanced Energy Design Guide: indoor pools, wet labs (e.g., chemistry), dirty dry labs (e.g., wood-working or auto shop) or other unique spaces with extraordinary heat or pollution generation. EAc1 198 Above the heading Approach and Implementation insert the following text: OPTION 3 ASHRAE Advanced Energy Design Guide for K-12 Schools Buildings For school buildings less than 100,000 square feet and which meet the scope restrictions outlined in the Introduction, the ASHRAE Advanced Energy Design Guide for K-12 Schools provides an effective means of limiting building energy usage, and documenting improved building energy performance without the need for a building energy model. The climate-specific recommendations listed in the ASHRAE Advanced Energy Design Guide should be incorporated into the project early in the building design in order to optimize building performance with minimal impact on capital costs. To comply with the prescriptive measures of the ASHRAE Advanced Energy Design Guide, the project team must first identify the climate zone where the building is located. Chapter 3 contains a United States map defining the eight climate zones by county borders. The project team can then find the appropriate Climate Zone Recommendation table identifying all of the prescriptive criteria required for their project. These criteria include recommendations for roofs, walls, floors, slabs, doors, vertical glazing, skylights, interior lighting, HVAC components, and service water heating. To achieve EA Credit 1, project teams must fully comply with all recommendations established in Errata Sheet for LEED for Schools Reference Guide 3 of 8

the Advanced Energy Design Guide for the climate zone in which the building is located. EAc1 201 At the end of the paragraph that starts with "Process energy cost shall be equal to at least 25%...", insert the following sentence: If the process energy cost is more than 25% of the baseline energy cost, the actual percentage must be used. EQc6.1 372 Left hand column, last paragraph, end of first sentence, change EAc1.2. to EAc1. There is no EAc1.2 Errata posted October 26, 2007 EAc9 405 In the first sentence under the title, Requirements delete the words and Impact Insulation Class (IIC). This standard does not apply to this credit. The sentence should then read: Design classrooms and other core learning spaces to meet the Reverberation Time (RT) requirements of ANSI Standard S12.60-2002, Acoustical Performance Criteria, Design Requirements and Guidelines for Schools. Errata posted October 15, 2007 Credit Page Erratum EAp2 181 In the first and second requirement bullets, strike references of (without amendments) that follow ASHRAE/IESNA Standard 90.1-2004. Project teams may use amendments to this standard, per the USGBC memo published April 26, 2007: http://www.usgbc.org/showfile.aspx?documentid=2664 EAc1 193 Under Option 1 Whole Building Energy Simulation, in the first and third requirement bullets, strike references of (without amendments) that follow ASHRAE/IESNA Standard 90.1-2004. Project teams may use amendments to this standard, per the USGBC memo published April 26, 2007: http://www.usgbc.org/showfile.aspx?documentid=2664 MRc2.1-2.2 269 In the first sentence of the intent, strike land-clearing so the intent reads as follows: Divert construction, and demolition and land-clearing debris from disposal in landfills and incinerators. As stated in the requirements section, land-clearing debris does not contribute to the MRc2 series. MRc6 294 Under Approach and Implementation, starting in the third sentence in the first paragraph, replace the following figures: For example, if the project has a $10 million budget, the materials cost (and subsequently 5% 2.5% of that cost) can be estimated using the 45% default rate. The team would calculate that the project would need to use at least $225,000 $112,500 of materials meeting the requirements of this credit ($225,000 $112,500 is 5% 2.5% of $4.5 million, which is 45% of the $10 million project cost). Under Exemplary Performance, in the last sentence, replace the following figure: For rapidly renewable materials, the percentage must be 10% 5% or greater. Errata posted October 25, 2007 Errata Sheet for LEED for Schools Reference Guide 4 of 8

EAc1 194 Replace the title and paragraph OPTION 2 ADVANCED BUILDINGS CORE PERFORMANCE This option is not yet available at the printing of the first edition of the LEED for Schools Reference Guide, but is expected to be an option in the future. Please check the CIR page on the USGBC Web site for updates. With OPTION 2 PRESCRIPTIVE COMPLIANCE PATH: Advanced Buildings Core Performance Guide (2-5 Points) Comply with the prescriptive measures identified in the Advanced Buildings Core Performance Guide developed by the New Buildings Institute. The following restrictions apply: The projects must be a school under 100,000 square feet. Project teams must fully comply with Sections One, Design Process Strategies, and Two, Core Performance Requirements. Minimum points achieved under Option 3 (2-3 points): Three (3) points are available for all school projects under 100,000 square feet that comply with Sections One and Two of the Core Performance Guide. Two (2) points are available for all other project types under 100,000 square feet (except health care, warehouse, or laboratory projects) that implement the basic requirements of the Core Performance Guide Additional points available under Option 3 (up to 2 additional points): Up to two (2) additional points are available to projects that implement performance strategies listed in Section Three, Enhanced Performance. For every three strategies implemented from this section, one point is available. Any strategies applicable to the project may be implemented except: 3.1-Cool Roofs 3.8-Night Venting 3.13-Additional Commissioning These strategies are addressed by different aspects of the LEED program and are not eligible for additional points under EA Credit 1. EAc1 198 At the bottom of the left hand column, under the title Option 2- Prescriptive Compliance Path replace the paragraph This option is not yet available at the printing of the first edition of the LEED for Schools Reference Guide but is expected to be an option in the future. Advanced Buildings Core Performance provides a prescriptive means of improving building energy performance. Please check the CIR page on the USGBC Web site for updates. With Errata Sheet for LEED for Schools Reference Guide 5 of 8

The Core Performance Guide describes the requirements of the program. The Guide is divided into five basic sections, describing different elements of the program requirements. In the Core Performance program, specific program requirements are referred to as criteria. Introduction The introduction section includes a brief overview of the Core Performance program, including the analysis protocols used to develop the program. The introduction also includes a Quick Start Guide that provides a program overview, and a table that correlates the program criteria (requirements) to other LEED credits. Section 1 Design Process Requirements REQUIRED by LEED This section describes a series of requirements that encourage the development of a more integrated building design by addressing the design process. Most of the criteria in this section are typically implemented by LEED project teams and can help the team to track building performance issues more effectively through the design and construction process. LEED projects following this prescriptive path for points under EA credit 1 must implement all of the criteria listed in this section of the Core Performance Guide. The specific criteria in this section of Core Performance are: Section 2 1.1 Identify Design Intent 1.2 Communicating Design Intent 1.3 Building Configuration 1.4 Mechanical System Design 1.5 Acceptance Testing 1.6 Operator Training 1.7 Performance Data Review Core Performance Requirements REQUIRED by LEED This section includes the specific energy performance measures that form the basis of achievement of energy savings under the Core Performance program, compared to ASHRAE 90.1-2004. LEED projects following this prescriptive path for points under EA credit 1 must implement all of the criteria listed in this section of the Core Performance Guide. (Note that under some specific conditions, certain criteria in Core Performance may not be applicable to specific projects. For example, projects without server rooms need not implement the Dedicated Mechanical Systems criteria.) The specific criteria in this section of Core Performance are: 2.1 Energy Code Compliance 2.2 Air Barrier Performance 2.3 Indoor Air Quality 2.4 Below Grade Insulation 2.5 Envelope Performance 2.6 Fenestration 2.7 Lighting Controls 2.8 Lighting Power Density Errata Sheet for LEED for Schools Reference Guide 6 of 8

Section 3 2.9 Mechanical Efficiency 2.10 Dedicated Mechanical Systems 2.11 Demand Control Ventilation 2.12 Hot Water System Efficiency 2.13 Fundamental Economizer Performance Enhanced Performance Strategies OPTIONAL for additional points The criteria identified in this section are not required when using the Core Performance program as a prescriptive path in LEED. These strategies can be used to increase the number of LEED points achieved using the Core Performance program. For each three additional Enhanced Performance Strategies implemented by a project, an additional one point can be achieved. (A maximum of two additional points can be achieved in addition to the points achieved from the required measures above.) Several of the criteria in the Enhanced Performance section of Core Performance do not qualify for additional points under EAc1. These strategies are addressed by different aspects of the LEED program. The list below identifies all of the Enhanced Strategy Criteria which MAY be used to achieve additional LEED EA credit 1 points: 3.1 (not applicable) 3.2 Daylighting and Controls 3.3 Additional Lighting Power Reductions 3.4 Plug Loads/Appliance Efficiency 3.5 Supply Air Temperature Reset (VAV) 3.6 Indirect Evaporative Cooling 3.7 Heat Recovery 3.8 (not applicable) 3.9 Premium Economizer Control 3.10 Variable Speed Drives 3.11 Demand Responsive Buildings 3.12 Renewable Energy 3.13 (not applicable) 3.14 Fault Detection Diagnostics Not all of the criteria listed in the Enhanced Strategy section can be applied effectively to all projects. The design team must evaluate the measures described to decide on applicability on a project by project basis. Section 4 Energy Modeling NOT APPLICABLE for LEED prescriptive path Option 3 The Core Performance program is designed as a prescriptive path for energy performance. Energy modeling is included as an option in Core Performance for projects that wish to demonstrate comparable performance under some state and utility programs. This is not a part of the LEED prescriptive path option. Projects which undertake energy modeling for LEED credit must comply with the energy performance requirements described in LEED using ASHRAE 90.1-Appendix G as a baseline. The Core Performance program is designed as a prescriptive measure program, and as such is calibrated to the prescriptive requirements of ASHRAE 90.1-2004. Projects which use Appendix G as a baseline may Errata Sheet for LEED for Schools Reference Guide 7 of 8

be required to utilize a different mechanical system baseline and therefore may not be able to demonstrate the same level of relative energy savings as suggested by the Core Performance program. The relative performance of the baseline does not affect the predicted energy use of the proposed building, but does affect the performance of the project relative to LEED. Errata posted September 14, 2007 Credit Page Erratum SS 22 Replace Table 1 with the table in this document listing SS credits: http://www.usgbc.org/showfile.aspx?documentid=3168 (PDF) Under Overview of LEED Prerequisites and Credits (continued), replace EQ Credit 9 with SS Credit 9, and replace EQ Credit 10 with SS Credit 10. Errata Sheet for LEED for Schools Reference Guide 8 of 8